    BESTWAY CEMENT LIMITED CHAKWAL 

    Proposal For Relocation of Kiln Inlet Gas

    sampling Point and Analyzer Probe 

    Production/Optimization Team 15-Mar-16 

  • 8/16/2019 Proposal for Relocation of Kiln Inlet Gas Sampling Point and Probe

    2/8

    Page 1 of 7 

    Table of ContentsSummary ....................................................................................................................................................... 2

    1-Gas analysis at Kiln Inlet for Process Optimization .................................................................................... 3

    2- Selection of sample point for Gas Analyzer Probe ................................................................................... 3

    3- Location of Gas Analyzer Probe at Kiln Inlet ............................................................................................. 3

    3.1- Standard location of Gas sampling probe at Kiln Inlet ...................................................................... 3

    3.2- Sampling Point Probe installation (By ITECA) .................................................................................... 4

    4- Location of Gas sampling probe at Kiln Inlet of BCL Chakwal .................................................................. 5

    5- New Proposed Installed position of Inlet Gas Analyzer ............................................................................ 5

    6- Comparison with Technical Sister Plants .................................................................................................. 6

    6.1 Inlet Gas Analyzer Probe location at Kohat Cement (Technically sister Plant) ................................... 6

    6.2- Gharibwal Cement (Position of Kiln inlet Analyzer Probe) ................................................................ 7

    7- Recommendation: .................................................................................................................................... 7

    References .................................................................................................................................................... 7

    Figure 1 : Standard location for Kiln inlet Analyzer ...................................................................................... 3

    Figure 2 Sample point Probe Installation ...................................................................................................... 4

    Figure: 3 Design for Optimum Probe Location ............................................................................................. 4

    Figure 4 Location of Inlet Gas Analyzer Probe at BCL Chakwal .................................................................... 5

    Figure 5 Proposed new location for Gas sampling ....................................................................................... 5

    Figure 6 Comparison between KOHAT cement and BCL Chakwal ................................................................ 6

    Figure 7 New Location and proposed shifting of Probe ............................................................................... 7

    http://c/Documents%20and%20Settings/Administrator/Desktop/Proposal%20for%20Relocation%20of%20Kiln%20Inlet%20Probe/Bull%20Nose%20Improvements.docx%23_Toc445819868http://c/Documents%20and%20Settings/Administrator/Desktop/Proposal%20for%20Relocation%20of%20Kiln%20Inlet%20Probe/Bull%20Nose%20Improvements.docx%23_Toc445819869http://c/Documents%20and%20Settings/Administrator/Desktop/Proposal%20for%20Relocation%20of%20Kiln%20Inlet%20Probe/Bull%20Nose%20Improvements.docx%23_Toc445819869http://c/Documents%20and%20Settings/Administrator/Desktop/Proposal%20for%20Relocation%20of%20Kiln%20Inlet%20Probe/Bull%20Nose%20Improvements.docx%23_Toc445819868

  • 8/16/2019 Proposal for Relocation of Kiln Inlet Gas Sampling Point and Probe

    3/8

    Page 2 of 7 

    Summary

      Kiln inlet is the best spot for gas analysis for better process monitoring. An accurate

    monitoring of process gasses at kiln inlet is of prime importance for optimized operation.

      For better analysis of gas the probe of gas analyzer should be installed at correct location,

    close to kiln seal on the side where the kiln wall is turning downwards (0-400mm in front

    of the seal and up to 200 mm beyond the seal).

      Chakwal Inlet analyzer position is not as per standard. The probe is located inside kiln

    inlet chamber wall towards the side of kiln moving downwards.

      Probe blockage is also a chronic issue being faced. This issue is because of installation of

     probe inside kiln inlet Chamber. Dust content inside kiln inlet chamber is on higher side.

      This was highlighted by Mr. Anis Haider (ITECA expert) and Mr. Sajjad Ullah (Team

    Leader Optimization Pakcem).

      World wide references are available for installation of Gas analyzer probe inside beyond

    Kiln Inlet seal. (FLS +ITECA)

      Comparison between technically sister plants KOHAT Cement and GHARIBWAL

    cement have installation of gas analyzer probe inside kiln inlet.

      At BCL Chakwal since feed enters from both side (A & B) feed pipes into Kiln inlet. Due

    to this design the probe location as per standard becomes critical.

      Relocation of Probe sampling point at Kiln inlet is possible. This provides an opportunity

    for plant optimization listed as under

    1. 

    Accurate analysis at kiln inlet.

    2. 

    Reducing the false air effect from Kiln inlet Seal.

    3. 

    Optimizing fuel consumption.

    4. 

    Optimizing power consumption

    5. 

    Reduce probe blockage.

    6. 

    More availability of Inlet gas Analyzer.

  • 8/16/2019 Proposal for Relocation of Kiln Inlet Gas Sampling Point and Probe

    4/8

    Page 3 of 7 

    1-Gas analysis at Kiln Inlet for Process OptimizationKiln inlet is the best spot for gas analysis for better process monitoring. An accurate monitoring of

    process gasses at kiln inlet will have following Key benefits

      Optimized fuel consumption

     

    Optimize quality

      Stable and safe kiln operation

      Kiln stop prevention

      Emission reduction

    2- Selection of sample point for Gas Analyzer Probe

    The sampling point for gas has to be taken in respect to following points

      Representative air

      No influence of false air

     

    Mechanical impact of material fall through

      Risk of material build up

      Dust impact

      Condensation from volatiles

    (FLSmidth, 2014) (Drawing Office Manual, 2008)

    3- Location of Gas Analyzer Probe at Kiln Inlet

    3.1- Standard location of Gas sampling probe at Kiln Inlet

    The probe of gas analyzer should be installed at correct location, close to kiln seal on the side where the

    kiln wall is turning downwards (0-400mm in front of the seal and up to 200 mm beyond the seal). The

    probe head should be 200~400mm away from brick layer of rotary kiln. Sketch shows standard location

    of gas Analyzer

    Figure 1 : Standard location for Kiln inlet Analyzer

  • 8/16/2019 Proposal for Relocation of Kiln Inlet Gas Sampling Point and Probe

    5/8

    Page 4 of 7 

    3.2- Sampling Point Probe installation (By ITECA)

    The probe is installed so that its tip is beyond kiln inlet seal to avoid influence of inlet seal false air.

    (Anis Haider ITECA)

    Figure 2 Sample point Probe Installation

    3.3- Design for Optimum probe location (Anis Haider ITECA) 

    Figure: 3 Design for Optimum Probe Location 

  • 8/16/2019 Proposal for Relocation of Kiln Inlet Gas Sampling Point and Probe

    6/8

    Page 5 of 7 

    4- Location of Gas sampling probe at Kiln Inlet of BCL Chakwal

    Chakwal Inlet analyzer position is not as per standard. The probe is located inside kiln inletchamber wall towards the side of kiln moving downwards. (Pictures attached of position of gas

    sampling probe at Kiln line # 2)

    Ideally analyzer should take sample from inside the kiln to avoid false air impact of Kiln Inlet

    seal. Moreover probe blockage is also a chronic issue being faced at due to high dust load inside

    kiln inlet.

    This was highlighted by Mr. Anis Haider (ITECA expert) and Mr. Sajjad Ullah (Team Leader

    Optimization Pakcem).

    5- New Proposed Installed position of Inlet Gas Analyzer

    Figure 5 Proposed new location for Gas sampling 

    Figure 4 Location of Inlet Gas Analyzer Probe at BCL Chakwal 

  • 8/16/2019 Proposal for Relocation of Kiln Inlet Gas Sampling Point and Probe

    7/8

    Page 6 of 7 

    6- Comparison with Technical Sister Plants

    At BCL Farooqia and Pakcem the angle of installed Gas analyzer probe is similar. At both plantsfeed is entering at kiln inlet from one side.

    At BCL Chakwal since feed enters from both side (A & B) feed pipes into Kiln inlet. Due to thisdesign the probe location as per standard becomes critical. To understand the possibilities

    comparison is drawn from position of inlet Gas analyzer at technically sister plants.

    6.1 Inlet Gas Analyzer Probe location at Kohat Cement (Technically sister Plant)

    Figure 6 Comparison between KOHAT cement and BCL Chakwal  

    Kohat Cement is technically sister plant with same design of Kiln inlet and feed pipes. Figure

    compares the analyzer position and design of KOHAT Cement and BCL Chakwal.

    Inlet Gas Analyzer Probe at KOHAT CEMENT Inlet design at BCL Chakwal (Similar to KOHAT

    Cement)

    nlet Gas Analyzer Position

  • 8/16/2019 Proposal for Relocation of Kiln Inlet Gas Sampling Point and Probe

    8/8

    Page 7 of 7 

    6.2- Gharibwal Cement (Position of Kiln inlet

     Analyzer Probe)

    Figure shows installation of probe at Gharibwal cement.

    7- Recommendation:Relocation of Probe sampling point at Kiln inlet is possible. This

    provides an opportunity for plant optimization. Relocation of gas

    analyzer will have following key benefits.

    1. 

    Accurate analysis at kiln inlet.

    2. 

    Reducing the false air effect from Kiln inlet Seal.

    3. 

    Optimizing fuel consumption.

    4. 

    Optimizing power consumption

    5. 

    Reduce probe blockage. (As at present probe blockage is due to its installation at high dust zone)

    6. 

    More available of Inlet gas Analyzer.

    Figure 8 New Location and proposed shifting of Probe

    References

    Anis Haider ITECA. (n.d.). Presentation on Inlet Gas Analyzer.

    FLSmidth. (2014). Kiln Inlet Analyzer Presentation . 

    Office, G. A. (2008). Kohat and Gharibwal Cement

    Plate form has to be shifted down

    for relocation of Inlet analyzer

    Probe

    roposed New Location

    Figure 7 Kiln Inlet sampling point and

    probe location