317-335-2602 P.O. Box 218 McCordsville, Indiana 46055 www.proportionair.com
THE FUTURE OF CONTROLTM
MM1/MM2CONTROL VALVESCLOSED LOOP PROPORTIONAL PRESSURE CONTROLS
-
PROPORTION-AIR 317-335-2602
BENEFITS
FEATURES PERFORMANCE CHARACTERISTICSAPPLICATIONS UniversalMountingDinRail,PanelMount,orSub-baseManifoldMount
Smallandcompact Fastandaccurate Mountsinanyposition Unaffectedbysupplypressurechanges Non-airconsuminginsteadystate
Takesuplessspace Reducesplumbing Simplifiesdesign Easytuningofsystemstability
ManufacturingandAutomation Instrumentation Medical ProcessControl Robotics TestandMeasurement
Commonsupplyportonsub-basemanifold Fieldserviceable Jumperselectablecommand0-10VDC,4-20mA Adjustablehysteresisband Interfaceswithavarietyofcontrolleroutputs 0-10VDCand4-20mAanalogoutput
-
317-335-2602 PROPORTION-AIR
FEATURES
FUNCTIONAL DESCRIPTION
PERFORMANCE CHARACTERISTICS
APPLICATIONS
TheMMseriesproportionalcontrolvalvesutilizeProportion-Airs unique closed loop controltechnology for superior control of pressurizedgases and fluids. The MM is designed to haveUniversal Mounting capabilities which includeDinRail, panelmount, ormanifoldmounting foruse on sub-base for multiple unit applications.Sub-baseconfigurationsareavailable from2-12units.Thesub-baseoffersacommonsupplyandexhaust port with individual controlled outletportstominimizeplumbingconnections.
The MM series units can be built as singleclosedloopordualclosedloop(cascadingloop)control valves. The MM1 and MM2 deliverpressurecontrolwhich is linearlyproportional toeither a DC current or DC voltage commandinput.The MM1 uses two solenoid valves to controlsystempressure.Onevalvefunctionsasaninletcontrol,theotherasanexhaustcontrol.Astraingaugepressuretransducermeasuresthesystempressure and provides a feedback signal to theelectronic controls. This feedback signal iscompared against the command signal. Any difference between the two signals causes one of the solenoid valves to open allowing pressure in or out of the system.
Closed loop proportional control of pressure ismaintainedinthismanner.
The MM2 is similar to the MM1 but uses adouble loop control scheme. In addition to theinternal pressure transducer, the MM2 alsoreceivesafeedbacksignal(0-10VdcStandard)fromanexternalsensingdevice.
The external signal functions as the primaryfeedback and is compared to the commandsignal. This comparison is summed with theinternal pressure transducer signal. A difference between the two comparisons causes one of the two solenoid valves to open allowing flow in or out of the system.
Since the secondary feedback is an electricalsignal,manytypesofsensorsmaybeusedasafeedback such as force, position, pressure,vacuum,etc.Ananalogoutput isalsostandardonboththeMM1andMM2tobeusedfordataacquisition or to a panel meter for display.The analog monitor signal is taken from theinternalpressuresensoronMM1sandfromthesecondaryfeedbackontheMM2.
LINEARITY RESPONSE TO STEP INPUT
Fig.1ThischartshowslinearcharacteristicsofMM products when given a ramp signal from0-10volts.Characteristicswouldbesimilar for4-20mAunits.
Fig. 2 Times for MM to fi ll/exhaust a closedchamber. Step command signal issuperimposed over pressure trace. Time isdetermined by difference between commandsignalandpressureachieved.
-
PROPORTION-AIR 317-335-2602
NOTES:Dimensionsareinches(mm)DimensionsareforreferenceuseAllportsare1/8-27NPTF
MANIFOLD MOUNT
DIMENSIONS
PANEL MOUNT
TYPICAL SUB-BASE APPLICATION
GENERAL SPECIFICATIONSDIN RAIL MOUNT
-
317-335-2602 PROPORTION-AIR
DIMENSIONS
TYPICAL SUB-BASE APPLICATION
GENERAL SPECIFICATIONSELECTRICALSupplyVoltage15-24VDCSupplyCurrent250mAmax(perunit)CommandSignal
Voltage0-10VDCCurrent4-20mAdifferential
2ndLoopInput0-10VDC MonitorSignal0-10or 4-20mA CommandSignalImpedance
Voltage4700Current100
2ndLoopSignalImpedance4700 MonitorSignal0-10VDC@10mA PHYSICALOperatingTemp32-158F[0-70C] Weight7lb[.3kg]*
*Weightisperunitnotincludingsub-basemanifold.
MECHANICALPressureRanges29.9in.Hg(VAC)-175psig(12barg)**[760mmHg(VAC)-1207kPa]OutputPressure0-100%ofrangeFlowRate
Standard1.2SCFM@100psig(6.9barg)inlet[[email protected]]HighFlow(S938)3.5SCFM@100psig(6.9barg)inlet[[email protected]]
CvCapacityStandard0.04HighFlow(S938)0.13
Min.ClosedEndVolume1in3FiltrationRecommended40micronminimal LinearityHysteresis+-0.2%F.S.BFSL(Adjustable) Repeatability+/-0.02F.S.Accuracy+/-0.2%F.S.TemperatureEffect+/-25C=+/-0.7%FSWettedPartsElastomers-Fluorocarbon;Manifold-BrassValves-Polyamide,AluminaCeramic,Epoxy,Silicon,GlassandSolderPortSizes1/8inch**Pressurerangesarecustomerspecified.***Othermanifoldmaterialsareavailable.ConsultFactory.
-
PROPORTION-AIR 317-335-2602
MaxINPressure:200psig(20.6bar)MaxOUTPressure:175psig(12bar)TypicalAccuracy:+/-0.2%(FullScaleofsensor) Regulators:nonePowerSupply:15VDC,24VDC,12VDC(OptionP1)
MM SERIES ORDERING INFORMATION
1=OpenLoop2=ClosedLoop B=Brass
D=DINRailMount(PortsonFace)M=ManifoldMount(PortsonBottom)P =PanelMount(PortsonFace)
H=ManifoldMount(NoThreads) N=NPTP=BSPP(Non-Standard)
MMSeries
EMonitorSignalRange
2Type
BManifoldMaterial
DMountType
NThreadType
EInputSignalRange
N= 0% Pressure Starts Below AtmosphereP=0% Pressure Starts Above AtmosphereZ=0% Pressure Starts at ZeroE=0to10VDC
I =4to20mADC K=0to5VDC V=1to5VDC
X=NoMonitorSignalC=4to20mADCSinkingE=0to10VDCK=0to5VDC1S=4to20mADCSourcingV=1to5VDC11OnlyavailableifthesameInputSignalRangeisselected
MM SERIES ACCESSORIESPower Connector
H14612
Mounting Kits
DINRail DRMKT-01PanelMount PMK-MMManifoldMount SeeHARDWAREKIT
Station Plug
H316
MM SERIES SUB BASE MANIFOLD
-
317-335-2602 PROPORTION-AIR
14.7=Startingat14.71,2,3,41Example2Maximum10%ofFullScalePressureifZeroOffsetisPressureType3LeftblankifZeroOffsetZ4PressureAvailableuptohundrethofaunit
N=0%PressureStartsBelowAtmosphereP=0%PressureStartsAboveAtmosphereZ=0%PressureStartsatZero
X = No Monitor SignalC = 4 to 20 mADC
Sinking
E = 0 to 10 VDCK = 0 to 5 VDC1S = 4 to 20 mADC
Sourcing
V = 1 to 5 VDC11Only available if the same InputSignal Range is selected
DYNAMICLISTDR=InstallDINRailMountingKit DV=DifferentialVoltageInputFA=FailToAtmosphereHE=HighFlowExhaustValveHI =HighFlowInletValveHQ=HighFlowInlet&ExhaustValvesNC=NoMatingConnectorShippedwithUnitP1=12VDCPower*Consultthefactoryifmorethan4optionsrequired
A=AbsolutePressure*G=GagePressure*MustbeAifPressureUnitofMeasureTypeisTR
PS =psiMB =mbarBR =barKP =kPaMP =MPaMH =mmHgIH =in.HgIW =in.H2OMW=mmH2OKG =kg/cmTR =TorrCW=cmH2O
120.55=Endingat120.551,2,31Example2175psig(12barg)Maximum3Pressureavailableuptohundredthofaunit
N=100%PressureEndsBelowAtmosphereP=100%PressureEndsAboveAtmosphereZ=100%PressureEndsatZero
5ZeroOffset
Pressure
NZeroOffsetPressureType
APressureTypeUOM
00Option
MBPressureUnit
120.55FullScalePress
PFullScalePressureType
MM SERIES SUB BASE MANIFOLDSBM-Series
2NumberofStations
2Stations3Stations4Stations5Stations6Stations7Stations8Stations9Stations10Stations11Stations12Stations
HK-Series
2NumberofStations
2Stations3Stations4Stations5Stations6Stations7Stations8Stations9Stations10Stations11Stations12Stations
-
Proportion-Airproductsarewarrantedtotheoriginalpurchaseronlyagainstdefectsinmaterialorworkmanshipforone(1)yearfromthedateofmanufacture.TheextentofProportion-Air'sliabilityunderthiswarrantyislimitedtorepairorreplacementofthedefectiveunitatProportion-Air'soption.Proportion-Airshallhavenoliabilityunderthiswarrantywhereimproperinstallationorfiltrationoccurred.
Allspecificationsaresubjecttochangewithoutnotice.THISWARRANTYISGIVENINLIEUOF,ANDBUYERHEREBYEXPRESSLYWAIVES,WARRANTIESORLIABILITIES,EXPRESS,IMPLIEDORSTATUTORY,INCLUDINGWITHOUTLIMITATIONANYOBLIGATIONOFPROPORTION-AIRWITHREGARDTOCONSEQUENTIALDAMAGES,WARRANTIESOFMERCHANTABILITY,DESCRIPTION,ANDFITNESSFORAPARTICULARPURPOSE.
.............................................................................................................................................................................................................................................................WARNING:Installationanduseofthisproductshouldbeunderthesupervisionandcontrolofproperlyqualifiedpersonnelinordertoavoidtheriskofinjuryordeath.
CATALOGNO.BRMM0113
PROPORTION-AIR, INC. 8250 N. 600 West, P.O. Box 218 McCordsville, Indiana USA 46055
Phone 317-335-2602 Fax 317-335-3853www.proportionair.com [email protected]
ONE PRODUCT THOUSANDS OF WAYS
Proportion-Airofferyouthetechnicalknowledge,expertiesandcapabilitiesthathavedevelopedconceptsintotheformostcontrolproductsinoperationaroundtheworld.