PROJECT GENERAL NOTES clg. ceiling cu condensing unit dia. diameter ea. each e.d. existing door e.g....
Transcript of PROJECT GENERAL NOTES clg. ceiling cu condensing unit dia. diameter ea. each e.d. existing door e.g....
PROJECT TITLE
CLIENT
Inches
01
1/2
1/4
34
5
REV. DATE DESCRIPTION
ISSUE FOR CONSTRUCTION DATE
DESIGNEDSCALE
DRAWING TITLE
DRAWN CHECKED
ORIGINAL SHEET SIZE
PROJECT NUMBER
PROJECT STATUS
SHEET NUMBER
REVISION NO.
Copyright © Atkins Limited (2015)
+1 813 282 7275
+1 813 282 9767
Tel:Fax:
4030 West Boy Scout Blvd.
Suite 700
Tampa
FL 33607
Tel:Fax:
www.atkinsglobal.com
DO NOT SCALE1 2 3 4
D
C
B
A
ANSID22X34
5
ATKINS DESIGN TEAM
ARCHITECTURE, STRUCTURAL, CULTURAL RESOURCES/ HISTORIC PRESERVATION
CONSULTANTS
P:\
100
056
419
- S
R 2
0 -
His
toric H
ou
se M
ove
\04
_C
AD
-BIM
\01_R
VT
\10
005
641
9_F
DO
T_S
R 2
0_H
isto
ric_H
om
e_R
elo
-A18_201
8 U
pd
ate
.rvt
6/2
1/2
018 1
0:2
0:4
7 A
M
COVER SHEET
HISTORIC HOUSE
RELOCATION
INTERLACHEN, FL
MBV MBV DAK
100056419
PHASE 1 - FOUNDATION DESIGN
FLORIDA DEPARTMENTOF TRANSPORTATION
DISTRICT 2
440 ATLANTIC AVE,INTERLACHEN, FLORIDA
G-001
MAY 18, 2018ABBREVIATIONS
A.C.T. ACOUSTIC CEILING TILEA.F.F. ABOVE FINISH FLOORA/C AIR CONDITIONINGAL ALUMINUM
BD. BOARD
CORR. CORRIDORC.J. CONTROL JOINTCLG. CEILINGCU CONDENSING UNIT
DIA. DIAMETER
EA. EACHE.D. EXISTING DOORE.G. EXISTING GLAZINGE.J. EXPANSION JOINTEL. ELEVATIONELEC. ELECTRICALEXIST. EXISTING
FE FIRE EXTINGUISHERFEC FIRE EXTINGUISHER CABINETF.F. FINISH FLOORF.V. FIELD VERIFY
GA. GALVANIZEDGYP. GYPSUM
HT. HEIGHTH.M. HOLLOW METALHR. HOUR
IN INCHESINST. INSTALLATION
JT. JOINT
MFG. MANUFACTURERMAX. MAXIMUMMIN. MINIMUMMTL. METALMP. MILE POST
N/A NONE APPLICABLEN.I.C. NOT IN CONTRACTNo. NUMBER
O.C. ON CENTERO.D. OUTSIDE DIAMETER
P.E. PROFESSIONAL ENGINEERPNL. PANELPR. PAIRR RADIOUS
R.A. REGISTERED ARCHITECTREQ'D REQUIRED
SEC. SECTIONSIM. SIMILARS.F. SQUARE FEETSPECS.SPECIFICATIONSS.C.W. SOLID CORE WOOD
TB. TABLETD. TRAVEL DISTANCETYP. TYPICAL
PROJECT LOCATION
EXISTING LOCATION440 ATLANTIC AVE
NEW PROPOSED LOCATIONSR-20 / FRANCIS STREET
SCOPE OF WORK:
RELOCATION OF A HISTORIC RESIDENCE WITH IN THE TOWN OF INTERLACHEN, FLORIDA. THE RESIDENCE IS BEING RELOCATED FROM 440 ATLANTIC AVENUE TO THE PROPOSED LOCATION NEAR SR-20 / FRANCIS STREET.
CODE INFORMATION:
JURISDICTION: PUTMAN COUNTY, FLORIDA
ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH THE FOLLOWING:
FLORIDA BUILDING CODE - RESIDENTIAL CODE 6TH ED (2017)FLORIDA BUILDING CODE - EXISTING BUILDINGS 6TH ED (2017)
PROJECT GENERAL NOTES:
THIS PROJECT CONSISTS OF PROVIDING NEW FOUNDATIONS FOR A RELOCATED, TWO-STORY RESIDENCE SIMILAR IN APPEARANCE TO THE RESIDENCE'S EXISTING FOUNDATION.
ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL CODES, REGULATIONS, GUIDELINES AND RESTRICTIONS UNDER THE JURISDICTION LOCATION FOR THIS PROJECT.
BUILDING DATA:
BUILDING AREA:1. FIRST FLOOR MAIN HOUSE APPROX. 857.49 SF2. FIRST FLOOR FRONT PORCH APPROX. 226.40 SF3. FIRST FLOOR KITCHEN ENCLOSED APPROX. 202.40 SF4. FIRST FLOOR REAR PORCH SCREENED APPROX. 72 SF5. SECOND FOOR MAIN HOUSE APPROX. 857.49 SF6. TOTAL GROSS (SF) APPROX. 2,216 SF
FINISHED TOP OF HOUSE PIERS: 95' - 3-1/2" - BASED ON SW CORNER TOPOGRAPHY AT 94'-0" PER REFERENCED SURVEY.
BUILDING HEIGHT: 35' - 3 5/8" - BASED ON 3D SCAN
NUMBER OF FLOORS: 2 + ATTIC
CURRENT BUILDING USE: RESIDENTIAL - SINGLE FAMILY
PROPOSED BUILDING USE: RESIDENTIAL - SINGLE FAMILY
ATKINS - DRAWING INDEX
GENERAL
G-001 COVER SHEET
STRUCTURAL
S-001 FOUNDATION PLAN
ARCHITECTURAL
A-101 EXISTING HOUSE REFERENCE INFORMATION - 440ATLANTIC AVENUE
A-102 FOUNDATION PLAN - AT RELOCATION SITE - SR-20 /FRANCIS STREET
A-103 FOUNDATION SECTION, DETAILS AND REFERENCED SITEPLAN
39
Exhibit "H"
1
2
3
4
5
6
7
8
A C E G J KB D F H
45
' -
4"
2
S-001
C1-0' - 4 1/2"
C1-0' - 4 1/2"
C1-0' - 4 1/2"
C1-0' - 4 1/2"
C1-0' - 4 1/2"
C1-0' - 4 1/2"
C1-0' - 4 1/2"
C1-0' - 4 1/2"
C1-0' - 4 1/2"
C1-0' - 4 1/2"
C1-0' - 4 1/2"
C1-0' - 4 1/2"
EL.F1 -2' - 10 1/4" EL.F1 -2' - 10 1/4" EL.F1 -2' - 10 1/4"
EL.F2 -2' - 7 1/4"
EL.F1 -2' - 7 1/4"
EL.F2 -2' - 7 1/4"EL.F1 -2' - 7 1/4"
EL.F2 -2' - 7 1/4"
EL.F2 -2' - 5" EL.F2 -2' - 5"EL.F2 -2' - 5" EL.F2 -2' - 5"
EL.F2 -2' - 1 7/8"EL.F2 -2' - 1 7/8" EL.F2 -2' - 1 7/8"
EL.F2 -2' - 1 7/8"
EL.F2 -1' - 10 1/2" EL.F2 -1' - 10 1/2" EL.F2 -1' - 10 1/2" EL.F2 -1' - 10 1/2"
EL.F2 -1' - 7 3/4" EL.F1 -1' - 7 3/4" EL.F2 -1' - 7 3/4"
EL.F1 -1' - 7 3/4"EL.F2 -1' - 7 3/4"
EL.F1 -1' - 3 3/4" EL.F1 -1' - 3 3/4" EL.F1 -1' - 3 3/4"EL.F1 -1' - 3 3/4"
EL.F2 -2' - 5"
4
S-001
3
S-001
S-001
5
EL.F2 -1' - 10 1/2"
2" 5' - 10" 7' - 7" 4' - 2" 3' - 5" 5' - 10" 2"
8' -
4 1
/2"
29
' -
3"
7' -
8 1
/2"
5"
4"
4"
5"
7"
1' -
5"
7"
3' -
0"
5' - 0"
10 3/4"
EL.F4 -2' - 1 7/8"
12" THICK CHIMNEY FOUNDATION PER SCHEDULE
7
S-001
EL.F3 -2' - 7 1/4"EL.F3 -2' - 7 1/4"
EL.F3 -1' - 7 3/4"
EL.F3 -1' - 7 3/4"
5"
3"
2' - 4"
4"
EL.F1 -2' - 10 1/4"
C3 C
2 C2
C2
C3
C2 C2 C
2
C2
C2
C2
C2
C2 C
2
C2
C2
C2
C2
C2
C3
C2 C
2
C2
C3
6' - 0"
EL.F1 -2' - 10 1/4"
EL.F1 -2' - 7 1/4"
C1-0' - 4 1/2"
C1-0' - 4 1/2"
CAST-IN-PLACE CONCRETE
1. CONCRETE WORK SHALL CONFORM TO THE REQUIREMENTS OF THEFOLLOWING CODES AND STANDARDS (LATEST EDITIONS):A. ACI 318 "BUILDING CODE REQUIREMENTS FOR REINFORCED
CONCRETE."B. ACI 117 "STANDARD TOLERANCES FOR CONCRETE CONSTRUCTION
AND MATERIALS".C. ACI 301 "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR
BUILDINGS".D. ACI 304 "RECOMMENDED PRACTICE FOR MEASURING, MIXING,
TRANSPORTING AND PLACING CONCRETE".E. ACI 305 "RECOMMENDED PRACTICE FOR HOT WEATHER
CONCRETING".F. ACI 311 "RECOMMENDED PRACTICE FOR CONCRETE INSPECTION".G. ACI 347 "RECOMMENDED PRACTICE FOR CONCRETE FORMWORK".H. ACI 315 "MANUAL OF STANDARD PRACTICE FOR DETAILING
REINFORCED CONCRETE STRUCTURES"I. ACI MANUAL OF CONCRETE PRACTICE-PARTS 1 THRU 5 AS
APPROPRIATE TO TYPE OF CONSTRUCTION.J. CRSI "MANUAL OF STANDARD PRACTICE".
2. CONCRETE SHALL BE NORMAL WEIGHT UNO AND SHALL CONFORM TOASTM C-94 IN ADDITION TO THE FOLLOWING:
A. PORTLAND CEMENT SHALL MEET ASTM C-150 TYPEI/II.B1. AGGREGATES FOR SLAB ON GRADE SHALL MEET ASTM C-33
(1" MAX).B2. AGGREGATES ELSEWHERE SHALL MEET ASTM C-33 (3/4" MAX).C. AIR ENTRAINING AGENT SHALL MEET ASTM C-260.D. WATER REDUCING AGENT SHALL MEET ASTM C-494.E. CALCIUM CHLORIDE SHALL NOT BE USED IN THE MIX.G. CURING COMPOUND SHALL MEET ASTM C309 TYPE 1 UNO.
3. CONCRETE SHALL HAVE THE MINIMUM ULTIMATE COMPRESSIVESTRENGTH OF 3000 PSI AT 28 DAYS. MIX DESIGNS SHALL BEAPPROVED BY THE ENGINEER BEFORE USE. MAX. W/C RATIO = 0.45
DESIGN CRITERIA
1. STRUCTURAL WORK SHALL BE IN ACCORDANCE WITH: FBC 2017AS ADOPTED AND SUPPLEMENTED BY LOCAL REGULATIONS ANDASCE 7-10
2. REFER TO DRAWINGS OF OTHER DISCIPLINES FOR DIMENSIONS ANDELEVATIONS NOT INDICATED ON STRUCTURAL DRAWINGS. NOTIFYARCHITECT / ENGINEER OF DISCREPANCIES PRIOR TO EXECUTION OFWORK.
3. COORDINATE SIZES AND LOCATIONS OF OPENINGS IN FLOORS,WALLS AND ROOFS WITH ARCHITECTURAL, MECHANICAL,ELECTRICAL, PLUMBING AND SITE REQUIREMENTS.
4. REFER TO ARCHITECTURAL, CIVIL, MECHANICAL, ELECTRICAL,PLUMBING AND SITE DRAWINGS FOR MATERIALS, COMPONENTS, ANDCONNECTIONS NOT SHOWN HEREIN, AND FOR ANCHORED,SUPPORTED AND EMBEDDED ITEMS WHICH AFFECT THE STRUCTURALWORK. VERIFY DETAILS AND DIMENSIONS WITH EQUIPMENTPURCHASED.
5. NO PROVISIONS HAVE BEEN MADE FOR FUTURE VERTICAL AND/ORHORIZONTAL ADDITIONS, MODIFICATIONS, AND/OR EXPANSIONSEXCEPT AS SHOWN ON THE STRUCTURAL DRAWINGS.
6. REFERENCED DATUM FOR THE PROJECT SHALL BE TAKEN AS 0'-0"ESTABLISHED FROM SLAB ON GRADE FINISH FLOOR. VERIFY ACTUALELEVATIONS WITH CIVIL DRAWINGS.
7. STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLEONCE IN SERVICE. NO CONSIDERATION FOR STABILITY AND SHORINGIS ASSUMED BY THE ENGINEER DURING THE BUILDING PROCESS. ITSHALL BE THE CONTRACTOR'S RESPONSIBILITY TO INSURE THESTABILITY AND SAFETY OF THE STRUCTURE AND ITS COMPONENTS BYDETERMINING AND IMPLEMENTING ERECTION PROCEDURES ANDSEQUENCE OF CONSTRUCTION. THIS INCLUDES TEMPORARYBRACING AND SHORING AS WELL AS SOIL STABILIZATION ANDPROTECTIVE MEASURES FOR ADJACENT EXISTING CONSTRUCTION.
8. STRUCTURAL WORK SHALL BE IN ACCORDANCE WITH: IBC 2009AS ADOPTED AND SUPPLEMENTED BY LOCAL REGULATIONS ANDASCE.
ROOF
FLOOR
GRAVITY LOADS
LIVE LOAD REDUCTION ON SUPPORTING ELEMENTS SHALL BE IN ACCORDANCE WITH THE BUILDING CODE. NO LIVE LOAD REDUCTION OF ROOF LOADING IS PERMITTED. UNIFORM DEAD LOAD IS ADDITIVE TO ACTUAL STRUCTURAL WEIGHTS.
LOCATIONUNIFORM
DEAD LOAD (PSF)
UNIFORM LIVE LOAD
(PSF)
15
15
20
40
ULTIMATE DESIGN WIND SPEED: Vult
RISK CATEGORY
WIND EXPOSURE
INTERNAL PRESSURE COEFFICIENT (ENCLOSED)
WIND LOADS: ASCE7-10/ 6TH ED. FBC
COMPONENTS AND CLADDING DESIGN WIND PRESSURE *q (ULT)
140 MPH
II
B
N/A
59 PSF
PER PLAN
1' -
6"
3" BRICK AT PERIMETER TYP. AT PERIMETER COLUMNS
PER PLAN
CONC. COLUMN REINF. PER SCHEDULE
NOTE TOP OF PIER ELEVATION = 0' - 0" U.N.O
F.G.
10" LAP
2' - 6"
2' -
5"
1' -
6"
1' - 5 1/2"
(4), #5 E.W.
F2
0' - 0"
HOOK TYP.10"
F.G.
COLUMN DOWELS PER SCHEDULE
2' - 0"
2' -
4 3
/4"
1' -
7"
1' - 2"
(3), #5 E.W.
F1
-0' - 4 1/2"
3"
F.G.
COLUMN DOWELS PER SCHEDULE
1' -
6"
1' - 6"
F3
3' - 0"
3' -
0"
6
S-001
4" 10"
BRICK AT PERIMETER
TYP. #5 VERT. REINF.
4"
4" 2' - 4" 4"
F3
4" BRICK LEDGE
1' -
6"
COL. REINF. PER PLAN
REINF. PER SCHEDLE
TOP OF FOOTING0' - 0"
EXISTING FLOOR JOISTS
EXISTING FLOOR BEAM
SIMPSON STHD10 EMBEDDED IN CONCRETE WITH 24, 10d NAILS (FILL ALL HOLES)
PROVIDE ISOLATION MATERIAL BETWEEN WOOD BEAM AND CONCRETE PIER
PROJECT TITLE
CLIENT
Inches
01
1/2
1/4
34
5
REV. DATE DESCRIPTION
ISSUE FOR CONSTRUCTION DATE
DESIGNEDSCALE
DRAWING TITLE
DRAWN CHECKED
ORIGINAL SHEET SIZE
PROJECT NUMBER
PROJECT STATUS
SHEET NUMBER
REVISION NO.
Copyright © Atkins Limited (2015)
+1 813 282 7275
+1 813 282 9767
Tel:Fax:
4030 West Boy Scout Blvd.
Suite 700
Tampa
FL 33607
Tel:Fax:
www.atkinsglobal.com
DO NOT SCALE1 2 3 4
D
C
B
A
ANSID22X34
5
ATKINS DESIGN TEAM
ARCHITECTURE, STRUCTURAL, CULTURAL RESOURCES/ HISTORIC PRESERVATION
CONSULTANTS
As indicated
FD
OT
- S
R 2
0 -
HIs
toric H
om
e R
elo
- S
tru
ctu
ral -
20
18
_la
test
_d
eta
ch
ed
.rvt
6/1
4/2
018 5
:00:4
4 P
M
FOUNDATION PLAN
HISTORIC HOUSE
RELOCATION
INTERLACHEN, FL
JAI JAI MR
100056419
PHASE 1 - FOUNDATION DESIGN
FLORIDA DEPARTMENTOF TRANSPORTATION
DISTRICT 2
440 ATLANTIC AVE,INTERLACHEN, FLORIDA
S-001
FOUNDATION PLAN NOTES
1. REFER TO GENERAL STRUCTURAL NOTES AND PROJECT SPECIFICATIONS
FOR DEFINITION OF SYMBOLS, ABBREVIATIONS, AND OTHER INFORMATION
AND CRITERIA NOT SHOWN ON PLAN.
2. FOUNDATION SIZES INDICATED ARE BASED ON THE SUBSURFACE
RECOMMENDATIONS PROVIDED BY THE GEOTECHNICAL ENGINEER FOR THE
PROJECT. REFER TO STRUCTURAL GENERAL NOTES FOR ADDITIONAL
INFORMATION.
3. VERIFY DIMENSIONS, ELEVATIONS, DEPRESSIONS, DRAIN LOCATIONS,
FINISHES AND LIMITS THEREOF, AND INFORMATION NOT EXPLICITLY
INDICATED ON STRUCTURAL DRAWINGS WITH THE DRAWINGS OF OTHER
DISCIPLINES PRIOR TO CONSTRUCTION.
4. COLUMN CENTERLINES SHALL COINCIDE WITH FOUNDATION CENTERLINES
UNLESS NOTED OTHERWISE ON PLAN, SECTIONS, AND DETAILS.
5. ALL REINFORCING IN FOUNDATION AND SLAB CORNERS, INTERSECTIONS,
TEES, AND CHANGES IN DIRECTION SHALL BE CONTINUOUS AND CORNER
REINFORCING SHALL BE PROVIDED AND LAPPED.
6 THE DESIGN FOR THE NEW FOUNDATION IS BASED ON THE LOCATION OF
THE EXISTING PIER FOUNDATIONS AND THE FIREPLACE FOUNDATION
WHICH MUST BE FIELD VERIFIED WHEN THE HOUSE IS RAISED ABOVE IT'S
EXISTING FOUNDATION. THE INTERIOR PIERS AND THE FIRE PLACE HAVE
BEEN LOCATED BASED ON SITE OBSERVATIONS FROM THE PERIMETER OF
THE EXTERIOR. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES BEFORE
CONSTRUCTION OF THE NEW FOUNDATION.
SOIL PREPARATION
1 PREPARE SOIL IN ACCORDANCE WITH PROCEDURES AND SPECIFICATIONS
PROVIDED BY ENVIRONMENTAL AND GEOTECHNICAL SPECIALISTS, INC.,
FILE NUMBER 22-97-18-01, DATED MAY 4, 2018
2 REMOVE FREE WATER FROM EXCAVATIONS BEFORE PLACING CONCRETE.
3 REMOVE EXISTING TOP SOIL, FILL, PAVEMENT OR FOUNDATIONS FROM THE
BUILDING AREA AS REQ'D.
4 PROVIDE SOIL POISONING UNDER BUILDINGS FOR TERMITE PROTECTION.
5 REINFORCING SHALL BE SUPPORTED WITH METHODOLOGY APPROVED BY
ENGINEER
6 ALLOWBLE BEARING PRESSURE = 1,800 PSF
1/4" = 1'-0"1
FOUNDATION PLAN TO BECONSTRUCTED AT NEW SITE( SR 20 / N. FRANCIS ST. )
3/4" = 1'-0"2 TYP. COLUMN SECTION
CONCRETE COLUMN SCHEDULE
MARK SIZE REINF. CONC. STRENGTH
C1 10"x14" (3), #5 VERT 3000 PSI
C2 10"x17.5" (3), #5 VERT 3000 PSI
C3 PER PLAN PER PLAN 3000 PSI
FOUNDATION SCHEDULE
TYPE SIZE THICKNESS REINF.
F1 24"X24" 18" (3), #5 E.W.
F2 18"X30" 18" (4), #5 E.W.
F3 36"X36" 18" (4), #5 E.W.
F4 36"X60" 12" #5 BOTT @ 6" O.C. E.W.
3/4" = 1'-0"4 SECTION AT E-53/4" = 1'-0"3 SECTION AT F-8
3/4" = 1'-0"5 PLAN VIEW AT H-2
8ISOMETRIC
3/4" = 1'-0"6 SECTION AT H-2
3/4" = 1'-0"7 SECTION AT FRAMING CONN.
40
THE ARCHITECT'S DOCUMENTS ONLY REPRESENT INFORMATION SUFFICIENT FOR THE CONTRACTOR TO BEGIN "THE CONTRACTOR'S REQUIRED WORK," WHICH INCLUDES THE PREPARATION OF DETAILED CONSTRUCTION DOCUMENTS, MORE COMMONLY KNOWN AS SHOP DRAWINGS AND SUBMITTALS, COORDINATION DRAWINGS, AND ALTERNATE SKETCHES, ALL OF WHICH SET OUT THE SPECIFIC AND FINAL DETAILS REQUIRED FOR PROCURING AND PLACING THE FINISHED WORK. BY CONTRAST, DRAWINGS BY ARCHITECTS MERELY REFLECT THE FINISHED DESIGN OF THE WORK.
IT IS IMPORTANT THAT ALL PARTIES UNDERSTAND THAT CONSTRUCTION DOCUMENTS ARE NOT INTENDED TO BE A COMPLETE SET OF INSTRUCTIONS ON HOW TO CONSTRUCT A BUILDING. CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, AND SITE SAFETY PRECAUTIONS ARE CUSTOMARILY ASSIGNED AS RESPONSIBILITIES OF THE CONTRACTOR TO GIVE THE CONTRACTOR FULL LATITUDE IN PREPARING BIDS AND CARRYING OUT THE CONSTRUCTION PHASE.
THE PURPOSE OF THE DIMENSIONS GIVEN IN THE ARCHITECT'S DRAWINGS IS TO DEFINE THE LIMITS OF AND PROVIDE GUIDANCE FOR PLACEMENT OF THE ELEMENTS OF THE WORK.
DESIGN PROFESSIONAL'S NOTES
NORTH
TRUE
NORTH
PLAN
1. FOUNDATION PIERS, FIREPLACE FOUNDATION AND OVERALL BUILDINGFOUNDATION DIMENSIONS ARE SHOWN FOR REFERENCE PURPOSES. ALLEXISTING DIMENSION ARE TO BE FIELD VERIFIED AS REQUIRED.
2. THE FOUNDATION GRID LINES ARE BASED ON THE CENTERLINE OF THEEXISTING BRICK PIER FOUNDATIONS.
GENERAL NOTES: EXISTING FOUNDATION
EXISTING FRONT PORCH
EXISTING PARTIALLY ENCLOSED REAR PORCH
EXISTING METAL ROOFING
EXISTING CHIMNEY
EXISTING ROOF ACCESS
EXISTING ROOF DORMER
EXISTING ROOF DORMER
NOTE: THE DESIGN FOR THE NEW FOUNDATION IS BASED ON THE LOCATION OF THE EXISTING PIER FOUNDATIONS AND THE FIREPLACE FOUNDATION WHICH MUST BE FIELD VERIFIED WHEN THE HOUSE IS RAISED ABOVE ITS EXISTING FOUNDATION. THE INTERIOR PIERS AND THE FIRE PLACE HAVE BEEN LOCATED BASED ON SITE OBSERVATIONS FROM THE PERIMETER OF THE EXTERIOR. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES BEFORE CONSTRUCTION OF THE NEW FOUNDATION.
8' -
4 1
/2"
29
' - 1
1"
7' -
8 1
/2"
27' - 10"
46
' -
0"
A B C
DA B C D E F G H J K
4" 2" 5' - 10" 2' - 9 1/2" 4' - 9 1/2" 4' - 2" 3' - 5" 5' - 10" 2" 6' - 0" 6"
8
6
7
5
4
3
2
1
7' -
6"
10
1/2
"7
' -
0 1
/4"
7' -
7 1
/4"
7' -
3 3
/4"
7' -
3 3
/4"
7' -
8 1
/2"
1. REFERENCE LINE FOR THE EDGE OF PORCH FRAMING BASED ON THEEXISTING CONDITIONS.
2. REFERENCE LINE FOR THE EDGE OF ENCLOSED PORCH FRAMING3. REFERENCE LINE FOR THE EDGE OF HOUSE FRAMING.4. EXISTING BRICK PIER FOUNDATION SYSTEM AT 440 ATLANTIC AVE.
KEY NOTES: EXISTING FOUNDATION
PROJECT TITLE
CLIENT
Inches
01
1/2
1/4
34
5
REV. DATE DESCRIPTION
ISSUE FOR CONSTRUCTION DATE
DESIGNEDSCALE
DRAWING TITLE
DRAWN CHECKED
ORIGINAL SHEET SIZE
PROJECT NUMBER
PROJECT STATUS
SHEET NUMBER
REVISION NO.
Copyright © Atkins Limited (2015)
+1 813 282 7275
+1 813 282 9767
Tel:Fax:
4030 West Boy Scout Blvd.
Suite 700
Tampa
FL 33607
Tel:Fax:
www.atkinsglobal.com
DO NOT SCALE1 2 3 4
D
C
B
A
ANSID22X34
5
ATKINS DESIGN TEAM
ARCHITECTURE, STRUCTURAL, CULTURAL RESOURCES/ HISTORIC PRESERVATION
CONSULTANTS
As indicated
P:\
100
056
419
- S
R 2
0 -
His
toric H
ou
se M
ove
\04
_C
AD
-BIM
\01_R
VT
\10
005
641
9_F
DO
T_S
R 2
0_H
isto
ric_H
om
e_R
elo
-A18_201
8 U
pd
ate
.rvt
6/1
8/2
018 3
:25:1
2 P
M
EXISTING HOUSEREFERENCE
INFORMATION - 440ATLANTIC AVENUE
HISTORIC HOUSE
RELOCATION
INTERLACHEN, FL
MBV MBV DAK
100056419
PHASE 1 - FOUNDATION DESIGN
FLORIDA DEPARTMENTOF TRANSPORTATION
DISTRICT 2
440 ATLANTIC AVE,INTERLACHEN, FLORIDA
A-101
1/4" = 1'-0"1EXISTING ROOF PLAN - FORREFERENCE
1/4" = 1'-0"2 EXISTING FOUNDATION PLAN
A EXISTING CONDITIONS B EXISTING CONDITIONS C EXISTING CONDITIONS D EXISTING CONDITIONS
2
2
1
1 1
1
3
33
3
2
1
4 4 4 4 4
44 4 4 4 4
4 4 4 4 4
44444
4 4 4 4 4
44444
4 4 4 4
1 2
41
1
2
3
4
5
6
7
8
A C E G J KB D F H
6
A-10327' - 10"
3
A-103
5
A-103
4
A-103
2
A-103
7' -
8 1
/2"
29
' - 1
1"
8' -
4 1
/2"
46
' -
0"
4" 2" 5' - 10" 2' - 9 1/2" 4' - 9 1/2" 4' - 2" 3' - 5" 5' - 10" 2" 6' - 0"
1. OVERALL DIMENSION ARE TO BE FIELD VERIFIED FROM EXISTING FOUNDATION.2. THE ROOF PLAN IS SHOWN FOR REFERENCE PURPOSES ONLY.3. ALL FOUNDATION PIERS ARE TO BE CAST IN PLACE CONCRETE, REFER TO
STRUCTURAL DRAWINGS, S-001.4. ALL FOUNDATION PIERS ON THE EXTERIOR PERIMETER WILL BE CLAD IN NEW
APPROVED BRICK. NEW BRICKS TO BE MODULAR SIZE, CONFORMING TO ASTMC216, MIN. GRADE, FBS TYPE, COLOR AS SELECTED BY ARCHITECT, SET INMASONRY CEMENT MORTAR CONFORMING TO ASTM C270, TYPE N, LAID INRUNNING BOND, FULLY BEDDED IN MORTAR, COURSED LEVEL WITH 1/4"TOLERANCE IN ALL DIRECTIONS.
5. THE HEIGHT/ DEPTH OF ALL FOUNDATION PIERS ON THE EXTERIOR PERIMETERTHAT RECEIVE THE NEW APPROVED BRICK ARE TO BE BUILT BASED ON THEVERTICAL COURSING DIMENSIONS OF THE NEW BRICK.
6. USE SALVAGED BRICK FROM THE ORIGINAL FOUNDATIONS OR APPROVED EQUALFOR RECONSTRUCTION OF THE FIREPLACE ONLY, AS NEEDED.
7. PIERS ARE TO BE LOCATED UNDER EXISTING BEAMS AND PROVIDE THE SAMELOADING LOCATIONS AS THE ORIGINAL FOUNDATION PIERS.
8. FINISH GRADE FOR ALL AREAS TO DIRECT WATER AWAY FROM THE NEW HOUSEFOUNDATIONS.
9. REFER TO THE STRUCTURAL DRAWINGS FOR THE NEW PIER FOUNDATIONSYSTEM.
10. PROVIDE EVERYTHING REQUIRED TO COMPLETE THE BRICK MASONRY AS SHOWNIN THE DRAWINGS HEREIN.
11. THE FOUNDATION GRID LINES ARE BASED ON THE CENTERLINE OF THE EXISTINGBRICK PIER FOUNDATIONS.
GENERAL NOTES: NEW FOUNDATION
NORTH
TRUE
NORTH
PLAN
1. NEW CAST IN PLACE CONCRETE FOUNDATION PIERS FOR HOUSE AT THESR-20 / FRANCIS STREET RELOCATION SITE. REFER TO NOTES ON 2/A-101AND STRUCTURAL DRAWINGS, S-001.
2. NEW CAST IN PLACE CONCRETE FOUNDATION PIERS FOR FRONT ANDREAR PORCHES AT THE SR-20 / FRANCIS STREET RELOCATION SITE.REFER TO NOTES ON 2/A-101 AND STRUCTURAL DRAWINGS, S-001.
3. NEW CAST IN PLACE CONCRETE FOUNDATION PIERS AT THE SR-20 /FRANCIS STREET RELOCATION SITE WITH NEW APPROVED BRICK SIMILARIN STYLE TO THE ORIGINAL FOUNDATION PIERS OR APPROVED EQUAL.
4. NEW CAST IN PLACE CONCRETE FOUNDATION PIERS FOR THE PORCH ATTHE SR-20 / FRANCIS STREET RELOCATION SITE WITH NEW APPROVEDBRICK SIMILAR IN STYLE TO THE ORIGINAL FOUNDATION PIERS ORAPPROVED EQUAL.
5. NEW CAST IN PLACE CONCRETE FIREPLACE FOUNDATION FOOTING.REFER TO NOTE ON 2/A-101 AND STRUCTURAL DRAWINGS, S-001.
6. REFERENCE LINE FOR THE EDGE OF PORCH FRAMING BASED ON THEEXISTING CONDITIONS.
7. REFERENCE LINE FOR THE EDGE OF ENCLOSED PORCH FRAMING8. REFERENCE LINE FOR THE EDGE OF HOUSE FRAMING.
KEY NOTES: NEW FOUNDATION
NORTH
TRUE
NORTH
PLAN
E
FG
H
SR 20
PROJECT TITLE
CLIENT
Inches
01
1/2
1/4
34
5
REV. DATE DESCRIPTION
ISSUE FOR CONSTRUCTION DATE
DESIGNEDSCALE
DRAWING TITLE
DRAWN CHECKED
ORIGINAL SHEET SIZE
PROJECT NUMBER
PROJECT STATUS
SHEET NUMBER
REVISION NO.
Copyright © Atkins Limited (2015)
+1 813 282 7275
+1 813 282 9767
Tel:Fax:
4030 West Boy Scout Blvd.
Suite 700
Tampa
FL 33607
Tel:Fax:
www.atkinsglobal.com
DO NOT SCALE1 2 3 4
D
C
B
A
ANSID22X34
5
ATKINS DESIGN TEAM
ARCHITECTURE, STRUCTURAL, CULTURAL RESOURCES/ HISTORIC PRESERVATION
CONSULTANTS
As indicated
P:\
100
056
419
- S
R 2
0 -
His
toric H
ou
se M
ove
\04
_C
AD
-BIM
\01_R
VT
\10
005
641
9_F
DO
T_S
R 2
0_H
isto
ric_H
om
e_R
elo
-A18_201
8 U
pd
ate
.rvt
6/1
9/2
018 1
:12:0
9 P
M
FOUNDATION PLAN -AT RELOCATION
SITE - SR-20 /FRANCIS STREET
HISTORIC HOUSE
RELOCATION
INTERLACHEN, FL
MBV MBV DAK
100056419
PHASE 1 - FOUNDATION DESIGN
FLORIDA DEPARTMENTOF TRANSPORTATION
DISTRICT 2
440 ATLANTIC AVE,INTERLACHEN, FLORIDA
A-102
1/4" = 1'-0"1
NEW ROOF PLAN ATPROPOSED RELOCATION SITE -FOR REFERENCE
1/4" = 1'-0"2NEW FOUNDATION PLAN ATPROPOSED RELOCATION SITE
E PROPOSED SITE DRIVEWAY F LOOKING NORTH G PROPOSED SITE HOUSE LOCATION H PROPOSED MOVEMENT PATH FOR HOUSE RELOCATION
12121
1 1 1
11
1 1 1
1 2 1 2 1
3 3
3
3
3 3
33
3 3
4 4 4 4
4 4 4 4
6
7
6
6 6
6
8
88
8
5
4
4
7
7
6 7
42
TOP OF PORCHFOOTINGS
94' - 11"
TOP OF MAINFOOTINGS95' - 3 1/2"
FRONT PORCH REAR PORCH
F.V
.
2' -
5 3
/4"
F.V
.
2' -
7 1
/4"
F.V
.
1' -
7 3
/4"
F.V
.
2' -
10
1/4
"
4 1
/2"
F.V
.
11
1/4
"
F.V
.
1' -
10
1/2
"
F.V
.
2' -
5"
F.V
.
2' -
1 7
/8"94' - 0"
EXISTING HOUSE FRAMING
GALV. FLASHING TERMITE SHIELD OVER 30# TAR PAPER
NEW CONCRETE PIER, REFERENCE STRUCTURAL
EMBEDDED STEEL STRAP TIE DOWN,REFERENCE STRUCTURAL
NEW CONCRETE FOOTING, REFERENCE STRUCTURAL
EXISTING REAR PORCH FRAMING
2' -
7"
FIE
LD
VE
RIF
Y
RE
Q'D
HT
GALV. FLASHING TERMITE SHIELD OVER 30# TAR PAPER - TO BE CONSTRUCTED BY OTHERS
NEW CONCRETE PIER, REFERENCE STRUCTURAL
EMBEDDED STEEL STRAP TIE DOWN,REFERENCE STRUCTURAL - TO BE CONSTRUCTED BY OTHERS
NEW CONCRETE FOOTING, REFERENCE STRUCTURAL
NEW PORCH FRAMING - TO BE CONSTRUCTED BY OTHERS
NEW APPROVED BRICK WITH TIES AT EVERY OTHER BLOCK ROW 1
0 1
/8"
F.V
.R
EQ
'D H
T
PORCH COLUMN - TO BE CONSTRUCTED BY OTHERS
GALV. FLASHING TERMITE SHIELD OVER 30# TAR PAPER
NEW CONCRETE PIER, REFERENCE STRUCTURAL
EMBEDDED STEEL STRAP TIE DOWN,REFERENCE STRUCTURAL
NEW CONCRETE FOOTING, REFERENCE STRUCTURAL
EXISTING HOUSE FRAMING
NEW APPROVED BRICK WITH TIES AT EVERY OTHER BLOCK ROW
2' -
1 7
/8"
2' -
1 7
/8"
F.V
.R
EQ
'D H
T
GALV. FLASHING TERMITE SHIELD OVER 30# TAR PAPER
NEW CONCRETE PIER, REFERENCE STRUCTURAL
EMBEDDED STEEL STRAP TIE DOWN,REFERENCE STRUCTURAL
NEW CONCRETE FOOTING, REFERENCE STRUCTURAL
EXISTING REAR PORCH FRAMING
NEW APPROVED BRICK WITH TIES AT EVERY OTHER BLOCK ROW
2' -
4 5
/8"
F.V
.R
EQ
'D H
T
EXISTING PORCH COLUMN
THE REFERENCED SURVEY, 1/A-103, INDICATES THE RELOCATED HOUSES PROPOSED LOCATION ON THE SR-20 / FRANCIS STREET SITE AND HAS BEEN PROVIDED FOR AN INFORMATION ONLY REFERENCE.
ALL INFORMATION RELATED TO THE NEW SITE WILL NEED TO BE FIELD VERIFIED. THE EXISTING ELEVATION CONTOURS MAY VARY FROM THE INFORMATION PROVIDED ON THE REFERENCED SURVEY.
THE ELEVATION CONTOURS HAVE BEEN PROVIDED FROM THE ST. JOHNS RIVER WATER MANAGEMENT DISTRICT MAPS. FIELD VERIFICATION WILL BE REQUIRED.
FDOT DISTRICT 2 WILL STAKE THE NEW LOCATION OF THE HOUSE ON THE RELOCATION SITE AT SR-20 / FRANCIS STREET PRIOR TO THE MOVE.
GENERAL NOTES: REFERENCED SITE PLAN
PROJECT TITLE
CLIENT
Inches
01
1/2
1/4
34
5
REV. DATE DESCRIPTION
ISSUE FOR CONSTRUCTION DATE
DESIGNEDSCALE
DRAWING TITLE
DRAWN CHECKED
ORIGINAL SHEET SIZE
PROJECT NUMBER
PROJECT STATUS
SHEET NUMBER
REVISION NO.
Copyright © Atkins Limited (2015)
+1 813 282 7275
+1 813 282 9767
Tel:Fax:
4030 West Boy Scout Blvd.
Suite 700
Tampa
FL 33607
Tel:Fax:
www.atkinsglobal.com
DO NOT SCALE1 2 3 4
D
C
B
A
ANSID22X34
5
ATKINS DESIGN TEAM
ARCHITECTURE, STRUCTURAL, CULTURAL RESOURCES/ HISTORIC PRESERVATION
CONSULTANTS
As indicated
P:\
100
056
419
- S
R 2
0 -
His
toric H
ou
se M
ove
\04
_C
AD
-BIM
\01_R
VT
\10
005
641
9_F
DO
T_S
R 2
0_H
isto
ric_H
om
e_R
elo
-A18_201
8 U
pd
ate
.rvt
6/2
0/2
018 4
:41:0
4 P
M
FOUNDATIONSECTION, DETAILSAND REFERENCED
SITE PLAN
HISTORIC HOUSE
RELOCATION
INTERLACHEN, FL
MBV MBV DAK
100056419
PHASE 1 - FOUNDATION DESIGN
FLORIDA DEPARTMENTOF TRANSPORTATION
DISTRICT 2
440 ATLANTIC AVE,INTERLACHEN, FLORIDA
A-103
1/2" = 1'-0"6
SECTION ELEVATION OF NEWFOUNDATION FOR PROPOSEDLOCATION
3/4" = 1'-0"3CONCRETE PIER - EDGE OFHOUSE AT REAR PORCH
3/4" = 1'-0"5BRICK PIER - EDGE OF FRONTPORCH
3/4" = 1'-0"4 BRICK PIER - SIDES OF HOUSE3/4" = 1'-0"2BRICK PIER - EDGE OF REARPORCH
1 REFERENCED SITE PLAN - FOR INFORMATION ONLY
NOT TO SCALE
NOTE: THE HEIGHT/ DEPTH OF ALL FOUNDATION PIERS ON THE EXTERIOR PERIMETER THAT RECEIVE THE NEW APPROVED BRICK ARE TO BE BUILT BASED ON THE VERTICAL COURSING DIMENSIONS OF THE NEW BRICK.
43