Progress on Overpressure Relief including triplets, feedboxes and special magnets

20
Progress on Overpressure Relief including triplets, feedboxes and special magnets L. Tavian LHC risk review, 5 March 2009

description

Progress on Overpressure Relief including triplets, feedboxes and special magnets . L. Tavian LHC risk review, 5 March 2009. Content. Basic assumptions Protection of inner triplets (IT) Protection of standalone (SAM), Semi-SAM and their current feed boxes (DFBM, DFBL) - PowerPoint PPT Presentation

Transcript of Progress on Overpressure Relief including triplets, feedboxes and special magnets

Page 1: Progress on Overpressure Relief including triplets, feedboxes and special magnets

Progress on Overpressure Relief including triplets, feedboxes and special magnets

L. TavianLHC risk review, 5 March 2009

Page 2: Progress on Overpressure Relief including triplets, feedboxes and special magnets

Content

• Basic assumptions• Protection of inner triplets (IT)• Protection of standalone (SAM), Semi-SAM

and their current feed boxes (DFBM, DFBL)• Protection of Arc current feed boxes (DFBA)• Protection of SC link at P3 (DSLC)• Summary

Page 3: Progress on Overpressure Relief including triplets, feedboxes and special magnets

Basic assumption: He inventoryEquipment He inventory

[kg] Remark

Standard subsector 820Mid arc subsector 1230DS subsector 680Standalone magnet ~30 Directly connected to Line D (+ 180 kg)Semi-standalone magnet ~60 Directly connected to Line D (+ 180 kg)Inner triplet 150 - 180 Depending on SC D1Current feed box X 30Current feed box M & L 4 - 7Current feed box A 13 - 23 Directly connected to DS subsector Superconducting link (P3) 260 Directly connected to Line C (+3400 kg)Superconducting link (P1, P5) 25 Directly connected to Line C (+3400 kg)

Page 4: Progress on Overpressure Relief including triplets, feedboxes and special magnets

Basic assumption: He discharge T

• Stored energy in main buses: 1200 MJ He discharge temperature: ~ 80 K

• Stored energy in IT: 8.8 MJStored energy in SAM: 1-7 MJ a factor ~ 140 w/r to main buses lower He discharge temperature: ~ 10-20 K

Page 5: Progress on Overpressure Relief including triplets, feedboxes and special magnets

SV discharge capability

0

2

4

6

8

10

12

14

16

18

20

1 10 100

Mas

s-flo

w [k

g/s]

He discharge temperature [K]

DN200DN160DN100DN63

Page 6: Progress on Overpressure Relief including triplets, feedboxes and special magnets

IT MCI mass flowI nner Triplet - MCI s

• Bus fault rupturing interconnect bellows:- Up to 20 kg/ s helium fl ow into cryostat.- Cryostat pressurized to many bar, similar to 19 Sep event.- Anchors to floor will break

for P > 1.5~2 bar.- Superconducting D1 could also

be pushed off its stands. - DFBX (square cryostat) could

be severely damaged by internal pressure. No spare DFBX* => 1-2 years to build new f rom scratch.

• I nter-turn short puncturing/ rupturing cold bore tube.- Scaling f rom a similar incident with an SSC R&D magnet, such an

event could create a 20-30 mm diameter hole in the beam tube.- Up to 10 kg/ s high pressure helium released into vacuum tube,

adjacent to experiments, in presence of electrical arc.* There are 8 DFBX of 6 variants

LHC Performance Workshop - 2009 J. Strait 21

J. Strait

Page 7: Progress on Overpressure Relief including triplets, feedboxes and special magnets

Protection of Inner TripletSlice type

S He m MCI T He Vacuum

He inventory

Stored energy

Vacuum volume Vac buffering

[cm2] [kg/s] [K] [kg] [MJ] [m3] [Inv. %] [s]Q-Q 1 60 20 10-20 180 8.8 15 20 1.8Q-DFBX 2 30 10 10-20 180 8.8 15 20 3.6DFBX 3 30 10 10 30 8.8 15 100 3.0D1-DFBX 4 30 10 10-20 180 1 15 20 3.6

With acceptable cryostat hydraulic

impedance

Too high cryostat hydraulic

impedance

DN200 DN200 DN200

DN200DN200DN200

D1 Q3 Q2AQ2B Q1

D1 Q3 Q2AQ2B Q1DFBX

DFBX 11

24

3

11

24

3

Page 8: Progress on Overpressure Relief including triplets, feedboxes and special magnets

Positions of the safety valves (1/2)Longitudinally:

Radial:

On Q3:• DN 200 on top or bottom

In the interconnects:• DN 200 on top, bottom or enlarging the existing safety valve

On DFBX:• DN 160 on the dished cover

H. Prin

Page 9: Progress on Overpressure Relief including triplets, feedboxes and special magnets

IT Protection recommendation

• Installation of the SV at the bottom of the cryostat. minimize the work load (5 to 3 days per IT) but require specific flow deflector to protect personnel and the QRL equipment in carbon steel

• The cryostat hydraulic impedance and the MLI blanket resistance still to be confirmed. doubling of the SV can solve the problem

Page 10: Progress on Overpressure Relief including triplets, feedboxes and special magnets

SAM protectionSlice type

S He m MCI T He Vacuum

He inventory

Stored energy

Vacuum volume Vac buffering

[cm2] [kg/s] [K] [kg] [MJ] [m3] [Inv. %] [s]SAM-DFBM 1 23 8 10-20 30 2 4 32 1.3DFBM 2 8 3 10 4 2 4 100 1.5

DN200 2 DN160or DN200

SAM

DFBM 12

DN100DN200 2 DN160or DN200

SAM

DFBM 12

Variant A: 1 DN200 onDFBM service chimney

Variant B: 1 DN200 onInterconnect sleeve

(Existing)

Page 11: Progress on Overpressure Relief including triplets, feedboxes and special magnets

SAM protection

27 cryo-magnets already need to be equipped with DN160 ports (He level capillary consolidation)

21 cryo-magnets needs port manufacturing : -2 DN160 ports per magnet- or 1 DN200 port per magnet

Page 12: Progress on Overpressure Relief including triplets, feedboxes and special magnets

Pressure relief for the DFBM

Variant A:1 valve DN200

Variant B:1 valve DN200

Interface to Quadrupole

Busbar interconnection

A. Perin

Page 13: Progress on Overpressure Relief including triplets, feedboxes and special magnets

Semi-SAM protectionSlice type

S He m MCI T He Vacuum

He inventory

Stored energy

Vacuum volume Vac buffering

[cm2] [kg/s] [K] [kg] [MJ] [m3] [Inv. %] [s]M-M 1 46 15 10-20 60 3 4 16 0.6M-DFBM 2 23 8 10-20 60 3 4 16 1.3DFBM 3 8 3 10 4 2 4 100 1.5

DN100 2 DN160or DN200

2 DN160or DN200

DFBMQ or D Q or D

123

DN200

2 DN160or DN200

2 DN160or DN200

DFBMQ or D Q or D

123

DN200

Variant A: 1 DN200 onDFBM service chimney

Variant B: 1 DN200 onInterconnect sleeve

Page 14: Progress on Overpressure Relief including triplets, feedboxes and special magnets

SAM / Semi-SAM / DSL protectionSlice type

S He m MCI T He Vacuum

He inventory

Stored energy

Vacuum volume Vac buffering

[cm2] [kg/s] [K] [kg] [MJ] [m3] [Inv. %] [s]M-M 1 46 15 10-20 60 3 17 68 2.7SSAM-DSL (HeI) 2 23 8 10-20 60 3 17 68 5.3SAM-DSL (HeI) 3 23 8 10-20 30 2 17 100 3.9SAM-DSL (SHe) 4 24 8 10-20 25 2 17 100 3.1DSL-DFBL (SHe) 5 24 8 10-20 25 7 17 100 3.1DFBL 6 8 3 10-20 7 7 17 100 2.6

DN2002 DN160or DN200

2 DN160or DN200

2 DN160or DN200

2 DN160or DN200

DFBL

DSL

SAMSAM Q or DQ or D13

6

3 24

5

44

Page 15: Progress on Overpressure Relief including triplets, feedboxes and special magnets

Pressure relief for the DSLs of IR 1 & 5: connections to magnets

Busbar interconnections

DN2002 DN160or DN200

2 DN160or DN200

2 DN160or DN200

2 DN160or DN200

DFBL

DSL

SAMSAM Q or DQ or D13

6

3 24

5

44

• pressure relief done through magnets

A. Perin

Page 16: Progress on Overpressure Relief including triplets, feedboxes and special magnets

DFBLbolted door

4 x 120A CL 8 x 120A CL11 x 6 kA CL

interface toSC link

interface to QRL

Pressure relief for the DFBLs

1 valve DN200

• 1 x DN200 valve

• installed on interface box cover• work in tunnel: remove cover, reinstall coverA. Perin

Page 17: Progress on Overpressure Relief including triplets, feedboxes and special magnets

DFBA protectionSlice type S He m MCI T He Vacuum He inventory Stored

energy Vacuum volume Vac buffering[cm2] [kg/s] [K] [kg] [MJ] [m3] [Inv. %] [s]

M-M 1 120 40 80 680 1200 67 6 1.0M-DFBA 2 60 20 80 680 1200 67 6 2.0DFBA (HeII) 3 60 20 80 680 1200 67 6 2.0DFBA (HeI) 4 24 8 80 13 1200 67 100 1.6HCM-LCM (HeI) 5 20 7 10-20 10 1 68 100 1.5LCM (HeI) 6 8 3 10 10 1 68 100 3.8LCM-Q6 7 23 8 10-20 10 1.5 72 100 1.3

2 DN100 DN200

2 DN100 DN2002 DN160

Q D

DFBAHCM

DFBALCM

Q D

DFBAHCM

DFBALCM

Q6

123456

12345

6

7

4 DN230

DN100

DN200DN200

4 DN230

Page 18: Progress on Overpressure Relief including triplets, feedboxes and special magnets

DFBA-HCM protection

75 mm

400 mm

1600 mm

100 mm – 150 mm

Ø3800 tunnel: interference between deflector and transport passage

A. Perin

Page 19: Progress on Overpressure Relief including triplets, feedboxes and special magnets

DFBLC-DSLC protectionSlice type

S He m MCI T He Vacuum

He inventory

Stored energy

Vacuum volume Vac buffering

[cm2] [kg/s] [K] [kg] [MJ] [m3] [Inv. %] [s]DSLC-DFB 5 20 7 10-20 260 1 15 29 11.1DSLC 6 40 13 10-20 260 1 15 29 5.6DFBLC 7 8 3 10-20 7 1 15 100 2.6

2 DN100 DN200

DN200

DN200DN200

DFBLC DSLCDFBAF

HCM

Q D123

4

55 6 67

DN200

4 DN230

Page 20: Progress on Overpressure Relief including triplets, feedboxes and special magnets

Summary• IT (8 units) 24 to 48 DN200 (depending on cryostat hydraulic impedance)• SAM & semi-SAM 48 magnets

– 27 to be equipped with 2 x DN160 on existing holes – 21 to be equipped with 2 x DN160 or 1 x DN200 – Remark: consolidation of two Q6 not possible during this SD

• DFBM 23 DN200 on service chimney or link• DFBL 5 DN200 on the end cover• DFBA HCM: 64 DN230 on access doors

LCM: 3 DN200 on service chimney– Remark: Consolidation of 8 DFBA not possible during this SD

• DSLC 3 DN200 on interconnect sleeves• Total for LSS ~200 to 250 relief valves (depending on open choices)

– Remark: 38 SV installation not possible with the present SD scenario: Mitigation measures under study for the protection of equipment (8 DFBA + 2 SAM) during the next run.