Programming for PowerFlex 7 Class
description
Transcript of Programming for PowerFlex 7 Class
Programming for these PowerFlex Drives (70, 70EC, 700Std, 700VC Series A & B)
1
Programming Instructions shown using a 20-HIM-A3
This is the “User Display” Window – The drive typically defaults to this window after 30 seconds
This is User Display Line 0
This is User Display Line 1
This is User Display Line 2
Auto/Man Information (The ALT View Function is allowed)Alarm Drive Status Direction
Blue Programming Keys
Key Descriptions Escape Pressing the Escape Key once takes you back one level. ESC Select
When at the parameter level pressing select will move the cursor to the line of the SelDisplay where the parameter value is. Then you are able to change its value. If the value of the parameter is at a Bit level then repeatedly pressing the Select key will move the cursor from one bit to the next (going from right to left).
Up and Down Arrows
Allows you to move between the different levels in the menu. When changing the parameter value these will increase or decrease the value. The longer you hold down the
key the faster it changes the value. Enter (This is the Universal key/Symbol used for “Enter”) Pressing this key will select the Item Highlighted in the menu and take you to the next level. Pressing this key when the value of a parameter has been changed will then write the changed value to the drive.
Key Descriptions continued Programming Instructions shown using a 20-HIM-A3
Key Descriptions
Start Pressing Start will cause the Drive Output/Power IGBT’s to start modulating or put the drive in a run condition. If no start inhibit is present, Mask, fault or alarm. If a digital input
| is programmed for 2 wire control. The Start Button is disabled unless P192 Bit 1 = 1.
Once started the STS LED should be solid Green. Jog
Jog From a stopped state press and HOLD Jog – this causes the Drive Output /Power IGBT’S to start modulating and follow the speed reference of P100 Jog1. If no start inhibit is present, Mask, fault or alarm. When the Jog Key is released - Then the Drive Output/ Power IGBT’s will stop modulating and the Drive will be in a stopped condition.
Backspace Pressing Backspace will delete / remove the text immediately to the left of the cursor. Stop Pressing stop will do one of the following based on P155 or P156 setting: Coast, Ramp, Ramp to Hold, DC Brake or Fast Brake. If a fault is displayed and is resetable pressing
O and releasing the stop key will clear the fault – when P241 is enabled.
2
Key Descriptions continued Programming Instructions shown using a 20-HIM-A3
Key Descriptions
Change Direction Pressing the change direction key will cause the Drive/Motor to go in the opposite Direction. Unless a mask is set to lock out this function. Or reverse disable P190 Digital Pot Up and Down Arrows
When the HIM is used as the speed reference. Either Press and hold or press and Release repeatedly the Up/Down arrows. Will Increase/Decrease the speed.
The Numerical Numbers can be utilized to increase or decrease a Parameter Value – when at a Parameter. When at the User display
3
window - these keys can be used to enter a speed reference. When the HIM is selected as a speed reference.
Decimal Point (500.20, 5.34, and 0.12 etc…) (Allows you to use a fractional value)
94 57 8
620
31
+/- Changes a Parameter value to a Positive or Negative
.
Key Descriptions continued
Key Descriptions
ALT (using the ALT Key) The ALT key is Color coded Yellow for 2nd function. This means whenever the ALT Key is
4
Pressed and Released the Keys that are labeled in Yellow text that is their 2nd function ALT
And are now available to be selected within a 3 sec time frame. (See below for details). Note: For the list below typically you will be at the “User Display” window.
(If after pressing ALT and the 2nd Function Key - nothing happens – then Press the Key once.) ESC(Then follow the prompts in the display)
2nd Function S.M.A.R.T S.M.A.R.T Pressing and Releasing the ALT key and then within Approximately 3 sec Press and ESC Release the Blue ESC key Displays the “S.M.A.R.T ” Start-up menu.
2nd Function View (At the “User Display” window) Displays only the Top Line of the display and an oversized Display line 1
View
Sel 2nd Function View (You must be at the “Main Menu” with “Parameter” Highlighted)
View Pressing and Releasing the ALT key and then within Approximately 3 sec Press and Release the Blue Sel key displays the “Parameter” Sub menu Sel
2nd Function Lang Lang Pressing and Releasing the ALT key and then within Approximately 3 sec Press and
Release the Blue UP Arrow key displays the Language Selection menu 2nd Function Auto / Man (Providing or Removing Manual control with the HIM) Auto / Man Pressing and Releasing the ALT key and then within Approximately 3 sec Press and
Release the Blue Down Arrow key Attempts to provide or remove Manual control 2nd Function Remove
Pressing and Releasing the ALT key and then within Approximately 3 sec Press and Release the Blue Enter key this Allows HIM removal without causing a fault (if the HIM is not the last controlling device or does not have manual control of the drive).
Press and Release ALT and then P. and R. (.) Press and Release ALT and then P. and R. (+/-) A Value can be entered as an Exponent Displays the Parameter Menu (Not available on PowerFlex 700) For Viewing / Editing Parameters. 2nd Function Exp 2nd Function Param#
Remove
Exp
. Param #
+/-
ALT / 2nd Function Examples
Press and Release
ALT
5
Alternate (ALT) Key is Active
SMART List: Digital IN2 Sel Stop/Brk Mode A Minimum Speed
This is displayed for Approximately 3 seconds
ALT
S.M.A.R.T
ESC
Displays the “S.M.A.R.T” Start-up menu.
ALT
0.00View
SelAmps
Press and Release
Then
Press and Release
Press and Release
Press and Release
Press and Release
Then
Provides a Magnified view of the User Display line 1
(Starting At the “User Display” window)
English? Français?
¿Español?
Italiano? Lang
Then Press and Release
ALT
Displays the Language menu.
ALT / 2nd Function Examples Continued
6
Auto Manual Go to HIM Manual Speed Control? Press Enter (↵)
Remove HIM Do you wish to? To Continue Press Enter (↵)
Auto / Man
Then
Press and Release
Press and Release
ALT
Param #: 1
Output Freq
0.0 HZ
ALT
ALT
Remove
Param # +/-
Press and Release
Press and Release
Press and Release
Press and Release
Then
Then
(To toggle between HIM and Auto control of the Drive – when using the HIM)
Allows HIM removal without causing a fault if the HIM is not actively controlling the drive/motor with logic commands (the only one Selected in the Logic mask) or providing a speed reference
Allows entry of a parameter number for viewing/editing
ALT / 2nd Function Examples Continued
(At the “Main Menu” with “Parameter” Highlighted)
View
Sel
ALT
Press and Release
Press and Release
Param Dspy Item: File Group Par
Then
7
Provides the selection of how parameters will be viewed and continued to be viewed this way even when AC power has been cycled.
Programming Instructions shown using a 20-HIM-A3 Programming/Changing Parameters
Starting At the “User Display” window
Changed Params Numbered List
Press and Release
ESCThen
Escape Select UP Down Enter ESC SelESC Sel
View
Sel
ALT
Press and Release
Press and Release Then
This window will be displayed This is the Main Menu: and has the following Selections in its list: Main Menu: Diagnostics Parameter Device Select Memory Storage Start-Up Preferences These Selections will be explained in greater detail – in the following pages / Menu Structure
Main Menu: Diagnostics Parameter Device Select
0.00 HZ
Programming/Changing Parameters
8
Note: Changing Parameter 196 to a value of “1 Advanced” – allows access to all Parameters.
Key in any parameter number you want to go to - then Press and Release the Enter key. This will take you to that parameter. Then you can Press and Release the Sel Key – Now you are able to change the value of the parameter -with the Up/ Down Keys or the Numerical Keys – once the value is changed -then you must Press and Release the Enter Key to write the change into the drive. Then you can key in the next parameter or Press and Release the Esc Key to go back to any previous Menu/Display. Note: Changing Parameter 196 to a value of “1 Advanced” – allows access to all Parameters.
Escape Select UP Down Enter ESC SelESC Sel
Then
Use the Up and Down Arrows to Highlight Numbered List Then Press the Enter Key
Then
This window will be displayed
View
Sel
Press and Release
ALT
Press and RThen
elease
Press Enter and this window will be displayedThis window will be displayed Then