Programming A-dec 500/300

description

Programming. A- dec 500/300. Learning Objectives. As a result of this training you will be able to: Identify an A-dec 500 touchpad from an A-dec 300 touchpad Configure handpieces on an A-dec 500 and A-dec 300 unit. A-dec 500 Touchpads. Standard Touchpad, Assistant’s or Doctor’s - PowerPoint PPT Presentation

Transcript of Programming

Page 1: Programming

ProgrammingA-dec 500/300

Page 2: Programming

Learning Objectives► As a result of this training you will be able

to:► Identify an A-dec 500 touchpad from an A-dec

300 touchpad► Configure handpieces on an A-dec 500 and A-dec

300 unit

Page 3: Programming

A-dec 500 Touchpads► Standard Touchpad, Assistant’s or Doctor’s► Deluxe Touchpad (2004 – 2006)► Endo Deluxe (May 2006)

Page 4: Programming

Standard Touchpad – Pg 52► System Status LED► Dental Light Control with

3-Way Switching► Manual Chair Positioning► Program Button► Presets► Cup Fill / Bowl Rinse

► Only if a Cuspidor is installed

► Auxiliary Buttons► A-dec relay functionality

only if a Cuspidor is not installed

Page 5: Programming

Chair Programming – Pg 53► Position Programming

1. Position the chair to the desired operating position, using the manual controls (arrows) on the touchpad or foot switch.

2. Press and release Program button (one beep).3. Within four seconds, press a position button (three beeps).

► Position 3 (X-ray/Rinse)1. Press and hold Program and Position 3

at the same time for three seconds. One beep confirms that the button 3 is now fully programmable.

Note: Disabling the x-ray/rinse function is a global function for Dr. A and B.

Page 6: Programming

Cuspidor Functions – Pg 54 ► Cuspidor Factory Presets

► Cup fill – 2.5 seconds► Bowl rinse – 30 seconds

Page 7: Programming

Handpiece Configuration► Overview 0 1 2 3 4

Page 8: Programming

Deluxe Touchpad – Pg 56► Allows switching between Standard and

Endo use of the EA51LT Electric Motor► Mode change:

► Select with “E” button► 4 memory settings

► M1=2,000 RPM► M2=10,000 RPM► M3=20,000 RPM► M4=40,000RPM

Page 9: Programming

Deluxe Touchpad – Pg 57► Dual Operator Support► Auxiliary Buttons► Cup Fill / Bowl Rinse

► Only if a Cuspidor is installed► If a Cuspidor is not installed,

buttons are inactive

► Water Coolant / Air Coolant

► Electric Handpiece / Ancillary Controls

Page 10: Programming

Programming – Pg 58-60

Page 11: Programming

Deluxe Touchpad Displays► Turbine selected► More than one of the

“Big Three” selected► Scaler► Electric Handpiece► Pneumatic Handpiece

► No Holdback Air► The power is on but there isn’t any

air to the unit

Page 12: Programming

Touchpad Programming► Factory Preset Functions

► Disable/Enable the Footswitch or Touchpad► Place the spare jumper in the “EN/DIS TP/FS”

position of the test points header.► Push the buttons to be disabled/enabled (PRGM,

PRGM 0, PRGM 1, PRGM 2, PRGM 3).► One beep means the button is disabled.► Three beeps means the button is enabled.

► Place the spare jumper back in the spare position.

Page 13: Programming

A-dec 300 Deluxe Touchpad► Programmable

chair positions► X-ray/rinse button► Cupfill/bowl rinse► Auto Light► Electric handpiece

operation► Endodontics

Page 14: Programming

Deluxe Touchpad Setup

Page 15: Programming

Thank you!► What questions do you have?