EXISTING INTAKE LOUVER AND DAMPER TO BE RELOCATED AS SHOWN. EX. 48"x80" INTAKE HOOD. REFER TO EXHAUST HOOD DETAIL 1 THIS SHEET. EX. 72"x40" OUTLET SLEEVE TO REMAIN EXISTING MECHANICAL DETAIL THIS SHEET UP ELEC PANELS NORTH ADDITION E 5a F Ex 1 2 3 6 5 4 4b 4a B 9 7b 6a C1 8 C3 8x Dy 7a 7bb 6 Ey E D C B ELEC PANELS EXISTING 2" WATER SERVICE EXISTING 4"SANITARY G G G G M EX. 1" GAS SERVICE EX. COGEN UNIT M EX. DCW UP G EX. 1" GAS TO CO.1 EX. 3/4" GAS TO F.1 & HWH.1 G G CO.1 Dy ROTATE EX. HOOD 180° TO ACCOMMODATE NEW GOOSENECK. REFER TO EXHAUST HOOD DETAIL 2 SHEET M1. 9 8 8x PROJECT NUMBER DRAWN CHECKED SCALE DATE FILE NAME DRAWING DATE DESCRIPTION REV. This drawing is the property of SPH Engineering Inc. and is not to be copied or distributed for any reason or by any means without the permission of the owner. DRAWING PROJECT CLIENT FAX: 519-539-5775 TEL: 519-539-5700 SPH ENGINEERING INC. REAL WORLD ENGINEERING SOLUTIONS N4S 8V8 WOODSTOCK, ONTARIO UNIT #1 65 SPRINGBANK AVE. N. 18134GMImainM4 STAMP NORTH ARROW DATE ISSUED FOR PRELIMINARY CLIENT REVIEW SITE PLAN APPROVAL BUILDING PERMIT TENDER CONSTRUCTION 2018-10-01 . Toll Free: 1-877-392-9766 Tel: (519) 842-4392 49 North Street East , Tillsonburg , ON N4G 1B4 email:[email protected] Fax: (519) 688-2470 CONSTRUCTION LTD. Grassmere www.grassmere.com design-build construction services R. W. SPENCER RE G I S T E R E D P R O F E S S I O N A L E N G I N E E R P R O V I N C E O F ON T A R I O 100191633 2018-10-01 2018-04-12 GG RS AS NOTED 18134 EXISTING/DEMO MECHANICAL LAYOUT PROPOSED ADDITIONS GMI BUILDING BEARDS LANE, WOODSTOCK, ON MD1 N EXISTING/DEMO MECHANICAL LAYOUT SCALE: 1 16 "=1'-0" EXISTING/DEMO MECHANICAL DETAIL SCALE: 1 4 "=1'-0" EXHAUST HOOD DETAIL 1 SCALE: 1 8 "=1'-0"

Transcript of PROFESIO D - grassmere.comgrassmere.com/wp-content/uploads/2018/10/M-E-Drawings-revised-… ·...

Page 1: PROFESIO D - grassmere.comgrassmere.com/wp-content/uploads/2018/10/M-E-Drawings-revised-… · profesio n a l e n g i n e e r p r o v in ceofon ta rio 100191633 2018-10-01 2018-04-12

EXISTING INTAKE LOUVER AND DAMPER

TO BE RELOCATED AS SHOWN.

EX. 48"x80" INTAKE HOOD.

REFER TO EXHAUST HOOD

DETAIL 1 THIS SHEET.

EX. 72"x40" OUTLET

SLEEVE TO REMAIN

EXISTING MECHANICAL

DETAIL THIS SHEET

UP

ELEC PANELS

NORTH

ADDITION

E

5a

F

Ex

1 2 3

654

4b4a

B

97b

6a

C1

8

C3

8x

Dy

7a 7bb

6

Ey

E

D

C

B

ELEC PANELS

EXISTING 2"

WATER SERVICE

EXISTING 4"∅SANITARY

G G G G

M

EX. 1" GAS SERVICE

EX. COGEN UNIT

M

EX. DCW UP

G

EX. 1" GAS TO CO.1

EX. 3/4" GAS TO F.1 & HWH.1

G G

CO.1

Dy

ROTATE EX. HOOD 180° TO ACCOMMODATE NEW GOOSENECK.

REFER TO EXHAUST HOOD DETAIL 2 SHEET M1.

98 8x

PROJECT NUMBER

DRAWN CHECKED

SCALEDATE

FILE NAME

DRAWING

DATEDESCRIPTIONREV.

This drawing is the property ofSPH Engineering Inc. and is not tobe copied or distributed for anyreason or by any means withoutthe permission of the owner.

DRAWING

PROJECT

CLIENT

FAX: 519-539-5775TEL: 519-539-5700

SPH ENGINEERING INC.REAL WORLD ENGINEERING SOLUTIONS

N4S 8V8WOODSTOCK, ONTARIO

UNIT #165 SPRINGBANK AVE. N.

18134GMImainM4

STAMP NORTH ARROW

DATE

ISSUED FORPRELIMINARYCLIENT REVIEWSITE PLAN APPROVAL

BUILDING PERMITTENDERCONSTRUCTION

2018-10-01

.

Toll Free: 1-877-392-9766

Tel: (519) 842-4392

49 North Street East , Tillsonburg , ON N4G 1B4

email:[email protected]

Fax: (519) 688-2470

CONSTRUCTION LTD.

Grassmere

ww

w.g

rass

me

re.c

om

design-build construction services

R. W. SPENCER

RE

G

IS

T

E

R

E

D

P

R

O

F

ESS

IO

N

A

L

E

N

G

IN

EE

R

P

R

O

V

I

N

C

E

OF

O

N

T

A

R

I

O

100191633

2018-10-01

2018-04-12

GG RS

AS NOTED

18134

EXISTING/DEMOMECHANICAL LAYOUT

PROPOSED ADDITIONSGMI BUILDING

BEARDS LANE, WOODSTOCK, ON

MD1

N

EXISTING/DEMO MECHANICAL LAYOUT

SCALE:

1

16

"=1'-0"

EXISTING/DEMO MECHANICAL DETAIL

SCALE:

1

4

"=1'-0"

EXHAUST HOOD DETAIL 1

SCALE:

1

8

"=1'-0"

Page 2: PROFESIO D - grassmere.comgrassmere.com/wp-content/uploads/2018/10/M-E-Drawings-revised-… · profesio n a l e n g i n e e r p r o v in ceofon ta rio 100191633 2018-10-01 2018-04-12

UP

SOUTH ADDITION

MAINTENANCE SHOP

NORTH

ADDITION

DN

DN

FS

CTRL

NO2

CO

NO2

CO

NO2

CO

EF-1

EF-2

LV-1 @ HEIGHT TO MATCH EXISTING

42x34 EXHAUST DUCT UP TO MATCH EXISTING.

OPEN ENDED WITH BIRDSCREEN.

DRILL DRAIN HOLES TO MATCH EXISTING.

TYP. 2

RELOCATED INTAKE LOUVER

HEIGHT TO MATCH EXISTING

MECHANICAL DETAILS

THIS SHEET

M

MD-1

M

MD-2

M

MD-3

NEW SUMP PIT WITH

SP-1 BELOW

NEW TRENCH DRAIN TD-1

SEE ARCHITECTURAL

DRAWINGS

CO

CO

CO

E

5a

D3

-3 -2-4

C0

C4

A

F

Ex

1

-5

G

2 3

1B

65

D1

A1

10

4

-5

1a-2-3-4

G

F

Ex

D2

C2

A1

4b4a

B

E

97b

6a

1a

C1

8

C3

8x

Dy

7a 7bb

6

Ey

E

D

C

B

A

98

7654321

NEW TRENCH DRAIN TD-1

SEE ARCHITECTURAL

DRAWINGS

4" @ 1%

4" @ 1%

1

1

1

RETURN DUCT ELBOW

BELOW ROOF

F-1 w/ CC.1

SUSPENDED

FROM CEILING

NEW 2" SAN FROM S.1

GGGGGGG

SP-2

AC-1 WALL MOUNTED AT HIGH

LEVEL. CONTRACTOR TO PROVIDE

MOUNTING AS REQUIRED.

FD.1

S.1

1-1/2" SUMP DISCHARGE @1%

TO TRENCH @ 6' A.F.F.

ROUTE PIPE BETWEEN BUILDING

COLUMNS AND EXTERIOR WALL.

HWT.1

NEW 3/4" DCW. INSULATE & HEAT TRACE LINE

FROM MAINTENANCE ROOM PENETRATION

BACK TO MECHANICAL ROOM CONNECTION.

A

400

TYP. 3

T

SUPPLY AND RETURN DUCT SIZES

TO MATCH FURNACE OPENINGS.

c/w ACOUSTIC INSULATION.

F.1

HRV.1

HRV.1 SUSPENDED

FROM CEILING

FRESH AIR INTAKE

LOUVER LV.2

EF.3

EF.2 ON ROOF ABOVE WELD

TABLE. DUCT OPEN ENDED

BELOW ROOF. REFER TO

ARCH. DRAWINGS.

FRESH AIR INTAKE

LOUVER LV.3

EF.4

EF.3 ON ROOF. 10"x10" DUCT

DOWN THRU ROOF.

REFER TO ARCH. DRAWINGS.

M

MD-4

T

REVERSE ACTING

THERMOSTAT

FS

CONNECT FAN

STARTER TO EF-3

CONNECT FAN

STARTER TO

EF-2/MD-3

1" DRAIN LINE INTO F.F.D. AT

TOP OF WALL. ROUTE DOWN

OUTSIDE OF WALL TO SAN BELOW

3" VENT THRU ROOF

6"∅ DUCT TYP.

HWT-1 ABOVE

HRV INTAKE

BELOW OPEN

TO SPACE

10"x10"

10"x10" DOWN THROUGH ELECTRICAL

ROOM CEILING TO EXHAUST GRILLE

AT CEILING HEIGHT.

B

300

EQUIPMENT

CONDENSATE

HWT-1 DRAIN LINE

ROUTE SUMP DISCHARGE DOWN

WALL AND INTO TRENCH

UP THRU ROOF

NEW 1/2" DCW &

DHW DN TO S.1.

RA

HEAT TRACE TO BE CHROMALOX SRF 5-2C

CABLE, WITH UBC INTEGRATED POWER AND

THERMOSTAT CONTROL, OR EQUIVALENT.

FFD

TRAP SEAL PRIMER

UNDER SINK

FS

EXISTING 2"

WATER SERVICE

EXISTING 4"∅SANITARY

G

M

EX. 1" GAS SERVICE. UPGRADE EX.

GAS MATER TO MEET NEW DEMAND.

COORDINATE WITH UNION GAS.

EX. COGEN UNIT

M

EX. DCW UP TO

MECHANICAL ROOM

EX. 1" GAS TO EX. COGEN UNIT

EX. 3/4" GAS TO EX. EQUIP

GGGG

NEW 3/4" GAS LINE TO NEW

F.1 ALONG EXTERIOR WALL

ABOVE PUMP ROOM ROOF.

CO.1

NEW 3/4" WATER LINE SERVING MAINTENANCE SHOP.

CONTRACTOR TO DETERMINE MOUNTING HEIGHT ON SITE.

CONNECT TO EXISTING WATER LINE IN MECHANICAL ROOM.

EX. WATER METER

BELOW

1'-0"

2'-0"

4'-0"

1

6

0

°

METAL BIRD SCREEN MOUNTED

WITH ANGLE IRON FRAME.

SEE DETAIL 3 THIS SHEET.

4

'

-

0

"

PROVIDE DUCT SUPPORT.

SEE STRUCTURAL DRAWING S2.1

DUCT SUPPORT, SEE

STRUCTURAL DRAWING S2.1

FIELD MEASURE EXISTING HOOD AND MATCH

GOOSENECK CROSS SECTION AREA TO HOOD.

FABRICATE GOOSENECK TO CURRENT SMACNA

STANDARDS. CONTRACTOR TO PROVIDE SHOP

DRAWINGS PRIOR TO FABRICATION.

4a4a 4b4b 5a5a 6a6a 66 8 8x 9

METAL SCREEN FRAME

BOLTS

SCREEN

ANGLE IRON REINFORCING

6'-6

3

4"

11'-1

5

8"±

NEW AIR INTAKE

GOOSENECK

PROJECT NUMBER

DRAWN CHECKED

SCALEDATE

FILE NAME

DRAWING

DATEDESCRIPTIONREV.

This drawing is the property ofSPH Engineering Inc. and is not tobe copied or distributed for anyreason or by any means withoutthe permission of the owner.

DRAWING

PROJECT

CLIENT

FAX: 519-539-5775TEL: 519-539-5700

SPH ENGINEERING INC.REAL WORLD ENGINEERING SOLUTIONS

N4S 8V8WOODSTOCK, ONTARIO

UNIT #165 SPRINGBANK AVE. N.

18134GMImainM4

STAMP NORTH ARROW

DATE

ISSUED FORPRELIMINARYCLIENT REVIEWSITE PLAN APPROVAL

BUILDING PERMITTENDERCONSTRUCTION

2018-10-01

.

Toll Free: 1-877-392-9766

Tel: (519) 842-4392

49 North Street East , Tillsonburg , ON N4G 1B4

email:[email protected]

Fax: (519) 688-2470

CONSTRUCTION LTD.

Grassmere

ww

w.g

rass

me

re.c

om

design-build construction services

R. W. SPENCER

RE

G

IS

T

E

R

E

D

P

R

O

F

ESS

IO

N

A

L

E

N

G

IN

EE

R

P

R

O

V

I

N

C

E

OF

O

N

T

A

R

I

O

100191633

2018-10-01

2018-04-12

GG RS

AS NOTED

18134

PLANT/MAINTENANCEROOM MECHANICAL

LAYOUT

PROPOSED ADDITIONSGMI BUILDING

BEARDS LANE, WOODSTOCK, ON

M1

N

MECHANICAL LAYOUT

SCALE:

1

16

"=1'-0"

MAINTENANCE SHOP MECHANICAL LAYOUT

SCALE:

1

16

"=1'-0"

OFFICE MECHANICAL LAYOUT

SCALE:

1

16

"=1'-0"

EXHAUST HOOD DETAIL 2

SCALE:

1

8

"=1'-0"

DETAIL 3

SCALE:6"=1'-0"

EXHAUST HOOD ELEVATION

SCALE:

1

16

"=1'-0"

AutoCAD SHX Text
1
AutoCAD SHX Text
ADDED MISSING TRANCH DRAIN
AutoCAD SHX Text
ADDED DRAIN PIPE SIZE
AutoCAD SHX Text
2018-10-01
Page 3: PROFESIO D - grassmere.comgrassmere.com/wp-content/uploads/2018/10/M-E-Drawings-revised-… · profesio n a l e n g i n e e r p r o v in ceofon ta rio 100191633 2018-10-01 2018-04-12

SOUTH ADDITION

DN

DN

30m x 38mm∅ FIRE HOSE

(98.4' x 1.5")

30m x 38mm∅ FIRE HOSE

(98.4' x 1.5")

FDC

VALVE

ROOM

EBB.1

D3

-3 -2-4

F

Ex

1

-5

G

2 3

1B

-5

1a-2-3-4

G

F

Ex

D2

C2

A1

E

D

C

B

A

6"∅ FIRE SERVICE. COMPLETE WITH DOUBLE

CHECK VALVE BACK FLOW PREVENTER.

CONNECT TO SITE SERVICES 5' FROM BUILDING.

DESIGN NOTES

1. STANDPIPE SYSTEM TO BE INSTALLED AS PER N.F.P.A. STANDARD #14 AND

ONTARIO BUILDING CODE (OBC) WHEREVER APPLICABLE.

2. PLANT AREA WHERE STANDPIPE SYSTEM IS TO BE INSTALLED IS AN UNHEATED

BUILDING. A DRY SYSTEM IS REQUIRED. ALL CONTROL VALVES, PUMPS, AND AIR

COMPRESSOR TO BE INSTALLED IN HEATED VALVE ROOM.

3. STATIC PRESSURE AT WATER MAIN WAS MEASURED AT 53 PSI. CONTRACTOR TO

DETERMINE PUMP REQUIREMENTS TO MEET MINIMUM HOSE STATION FLOW AND

PRESSURE REQUIREMENTS AS PER OBC 3.2.9.

4. FIRE PROTECTION CONTRACTOR TO DETERMINE COMPRESSED AIR

REQUIREMENTS. A STAND ALONE COMPRESSOR IS TO BE SUPPLIED IN THE VALVE

ROOM.

5. ALL MATERIALS TO BE U.L.C. LISTED AND APPROVED BY ALL LOCAL AUTHORITIES.

6. ALL SUPERVISED VALVES, FLOW SWITCHES AND LOW PRESSURE MONITORING

SWITCHES TO BE CONNECTED TO EXISTING FIRE ALARM SYSTEM (IF APPLICABLE)

OR NEW FIRE ALARM OR NEW FIRE ALARM SYSTEM (IF APPLICABLE) BY

ELECTRICAL CONTRACTOR.

7. POWER SUPPLY TO STANDPIPE SYSTEM COMPONENTS, SUCH AS SUPERVISED

VALVES AND AIR COMPRESSORS, TO BE PROVIDED BY ELECTRICAL CONTRACTOR

AS REQUIRED.

8. PROVIDE FIRE ALARM VERIFICATION BEFORE COMPLETION OF PROJECT IN

ACCORDANCE WITH O.B.C. 3.2.4.5. SUBMIT COPY OF TECHNICIANS REPORT AND

CERTIFICATE.

DESIGN CRITERIA

1. STANDPIPE SYSTEM TO BE HYDRAULICALLY DESIGNED IN ACCORDANCE WITH

N.F.P.A. 14 "INSTALLATION OF STANDPIPE AND HOSE SYSTEMS" FOR A DRY SYSTEM.

STANDPIPE GENERAL NOTES:

1. FIRE PROTECTION CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR HYDRAULIC

CALCULATIONS AND PIPING SIZE FOR OWNERS INSURANCE COMPANY APPROVAL.

2. DRAWINGS AND CALCULATIONS ARE TO BE SEALED BY A PROFESSIONAL

ENGINEER REGISTERED IN ONTARIO AND COMPETENT FOR WORK DESIGNED.

3. PROVIDE CUTTING AND PATCHING FOR WORK AND ARRANGE TO MAKE GOOD ALL

FINISHES.

PROJECT NUMBER

DRAWN CHECKED

SCALEDATE

FILE NAME

DRAWING

DATEDESCRIPTIONREV.

This drawing is the property ofSPH Engineering Inc. and is not tobe copied or distributed for anyreason or by any means withoutthe permission of the owner.

DRAWING

PROJECT

CLIENT

FAX: 519-539-5775TEL: 519-539-5700

SPH ENGINEERING INC.REAL WORLD ENGINEERING SOLUTIONS

N4S 8V8WOODSTOCK, ONTARIO

UNIT #165 SPRINGBANK AVE. N.

18134GMImainM4

STAMP NORTH ARROW

DATE

ISSUED FORPRELIMINARYCLIENT REVIEWSITE PLAN APPROVAL

BUILDING PERMITTENDERCONSTRUCTION

2018-10-01

.

Toll Free: 1-877-392-9766

Tel: (519) 842-4392

49 North Street East , Tillsonburg , ON N4G 1B4

email:[email protected]

Fax: (519) 688-2470

CONSTRUCTION LTD.

Grassmere

ww

w.g

rass

me

re.c

om

design-build construction services

R. W. SPENCER

RE

G

IS

T

E

R

E

D

P

R

O

F

ESS

IO

N

A

L

E

N

G

IN

EE

R

P

R

O

V

I

N

C

E

OF

O

N

T

A

R

I

O

100191633

2018-10-01

2018-04-12

GG RS

AS NOTED

18134

FIRE PROTECTIONAND VALVE ROOM

LAYOUTS

PROPOSED ADDITIONSGMI BUILDING

BEARDS LANE, WOODSTOCK, ON

M2

N

FIRE PROTECTION LAYOUT

SCALE:

1

16

"=1'-0"

Page 4: PROFESIO D - grassmere.comgrassmere.com/wp-content/uploads/2018/10/M-E-Drawings-revised-… · profesio n a l e n g i n e e r p r o v in ceofon ta rio 100191633 2018-10-01 2018-04-12

HVAC EQUIPMENT SCHEDULE

TAG ID DESCRIPTION MAKE MODEL

AIR FLOW

(CFM)

HEATING

INPUT

COOLING

CAPACITY

VOLTAGE

UNIT WEIGHT

kg (lbs)

REMARKS

F.1 NEW FURNACE GOODMAN GMS800603AN 1200 60 MBH

115/1/60

HEATING

OUTPUT

-48 MBH

40 (88)

INSTALL AS PER MANUFACTURER'S INSTRUCTIONS.

MCA (AMPS) MOCP (AMPS)

154.8

HRV.1 HEAT RECOVERY VENTILATOR LIFEBREATH 195 DCS 216 -

120/1/60

--

40 (88)

INSTALL AS PER MANUFACTURER'S INSTRUCTIONS.151.5

AC.1 AIR CONDITIONER GOODMAN GSX130301 - -

208/1/60

27 MBH-

52.3 (115)

INSTALL AS PER MANUFACTURER'S INSTRUCTIONS.2516.7

CC.1 COOLING COIL GOODMAN CHPF2430B6 - - -27 MBH-

25 (55)

INSTALL AS PER MANUFACTURER'S INSTRUCTIONS.--

NOTE: EQUIPMENT OF EQUAL PERFORMANCE IS ACCEPTABLE

EBB.1 ELECTRIC BASEBOARD HEATER OUELLET OPR1002 - -

120/1/60

-1000 W

11.8 (26)

INSTALL AS PER MANUFACTURER'S INSTRUCTIONS.15-

ASHRAE 62.1 VENTILATION SUMMARY

SPACE IDENTIFICATION

FAB SHOP

SPACE TYPE

GENERAL MANUFACTURING

SPACE AREA

(SQ. FEET)

800

NUMBER OF

OCCUPANTS

3

AREA OUTDOOR

AIR RATE

(CFM/SQFT)

0.18

PEOPLE OUTDOOR

AIR RATE

(CFM/PERSON)

10

DISTRIBUTION

EFFECTIVENESS

(Ez)

1.0

SYSTEM EFFICIENCY

(Ev)

0.9

DIVERSITY

1.0

REQUIRED OUTDOOR

AIR RATE

(CFM)

220

LOUVERS & DAMPERS SCHEDULE

MOTORIZED DAMPER

TAG ID DESCRIPTION SIZE MAKE REMARKS

TAMCO

MODEL

SERIES 1000

BELIMO DAMPER MOTOR & ALL CONTROLS

MOTOR ELECTRICAL: 120/1/60, END SWITCHES

STATIONARY DRAINABLE LOUVER E.H. PRICE DE439

W/ FORMED METAL SILL & BIRD SCREEN

TO SUIT LOUVER

& EXHAUST FAN

108x84

MD-1, 2,

3, 4

LV-1

STATIONARY DRAINABLE LOUVER E.H. PRICE DE439

W/ FORMED METAL SILL & BIRD SCREEN

26x24LV-2

STATIONARY DRAINABLE LOUVER E.H. PRICE DE439

W/ FORMED METAL SILL & BIRD SCREEN

14x12LV-3

NOTE: EQUIPMENT OF EQUAL PERFORMANCE IS ACCEPTABLE

HEIGHTUNIT#

HWT.1

CAPACITY

WATER HEATER SCHEDULE

INPUT (kW)

MAKE MODEL # DIAMETER SHIPPING WEIGHTTYPE

A.O.SMITH EJC-6 6 USG ELECTRIC 1650 15.25" 14.25" 35 lbs

WEIGHT W/ WATER

~85 lbs

NOTE: EQUIPMENT OF EQUAL PERFORMANCE IS ACCEPTABLE

UNIT # DESCRIPTION

HWH.1

EX. HOT WATER HEATER

INPUT CAPACITY (MBH)

(WHEN COGEN UNIT IS RUNNING)

-

GAS DEMAND SCHEDULE

TOTAL GAS DEMAND 411 MBH

F.1 -

CO.1 351

AC.1 60

EX. COGEN UNIT

NEW FURNACE

EX. FURNACE

INPUT CAPACITY (MBH)

(WHEN COGEN UNIT IS NOT RUNNING)

76

224 MBH

88

-

60

MECHANICAL LEGEND

SYMBOL DESCRIPTION

BURIED SANITARY PIPE

DOMESTIC COLD WATER SUPPLY

3" FLOOR DRAIN

FD.1

PIPE DOWN

PIPE UP

DOMESTIC HOT WATER SUPPLY

SYMBOL DESCRIPTION

HOSE BIB COMPLETE WITH VACUUM BREAKER

TSP

TRAP SEAL PRIMING UNIT

G G

NEW GAS

G G

GAS VALVE

PRESSURE REDUCING VALVE

SUPPLY, RETURN, TRANSFER, EXHAUST,

AIR GRILLE/REGISTER TAGD

250

CFM

TYPE

T

CONTROL THERMOSTAT

CARBON MONOXIDE MONITOR

MMOTORIZED AIR DAMPER

CONTROL WIRING

NITROGEN DIOXIDE MONITOR

CO

NO2

FS

CTRL

FAN STARTER

HAZARDOUS GAS CONTROL PANEL

ROOFTOP EXHAUST FAN

ISOLATION VALVE

BV

BALANCING VALVE

BURIED SANITARY PIPE

EXISTING PIPE

SIDEWALL EXHAUST FAN

CO

SANITARY CLEAN OUT

T

REVERSE ACTING THERMOSTATSIAMESE FIRE DEPARTMENT CONNECTION

RA

3" FUNNEL FLOOR DRAIN

FFD.1

EXHAUST FAN SCHEDULE

EF-1,2

WALL MOUNTED EXHAUST FAN

FAN # DESCRIPTION MAKE MODEL

AIR FLOW

(CFM)

STATIC

PRESSURE

FAN MOTOR

kW (HP)

VOLTAGE

UNIT WEIGHT

kg (lbs)

GREENHECK AER-E36C-310-A 18000

2.87 (3.85)

0.4 in wc

208/60/3 72.7 (160)

FLA

16.7

EF-3 ROOF MOUNTED EXHAUST FAN GREENHECK GB-161 1800

0.142 (0.19)

0.2 in wc

120/1/6028.6 (63)

5.8

EF-4 ROOF MOUNTED EXHAUST FAN GREENHECK G-090-E 300

0.015 (0.02)

0.2 in wc

120/1/60 11.8 (26)

-

NOTE: EQUIPMENT OF EQUAL PERFORMANCE IS ACCEPTABLE

SEQUENCE OF OPERATIONS - GAS DETECTIONS SYSTEMS

1. LOW LEVEL ALARM NITROGEN DIOXIDE (NO2)

IF ANY NITROGEN DIOXIDE (NO2) SENSOR POINT DETECTS 0.72PPM GAS OR MORE, DAMPERS MD-1 &

MD-2's SHALL OPEN & WHEN FULLY OPENED AS SENSED BY THEIR END SWITCHES EF-1's SHALL BE

ENERGIZED. LOW ALARM LED LIGHTS FOR POINT IN ALARM.

2. HIGH LEVEL ALARM NITROGEN DIOXIDE (NO2)

IF NITROGEN DIOXIDE (NO2) GAS CONCENTRATION LEVELS CONTINUE TO RISE & ANY SENSOR

DETECTS 2.0PPM GAS, W/ VENTILATION CONTACTS CONTINUING TO OPERATE, THE UNIT AUDIBLE

ALARM SOUNDS & HIGH ALARM INDICATOR LIGHTS ON THE CENTRAL CONTROLLER DISPLAY.

3. LOW LEVEL ALARM CARBON MONOXIDE (CO)

IF ANY CARBON MONOXIDE (CO) SENSOR POINT DETECTS 25PPM GAS OR MORE, DAMPERS MD-1 &

MD-2's SHALL OPEN & WHEN FULLY OPENED AS SENSED BY THEIR END SWITCHES EF-1's SHALL BE

ENERGIZED. LOW ALARM LED LIGHTS FOR POINT IN ALARM.

4. HIGH LEVEL ALARM CARBON MONOXIDE (CO)

IF CARBON MONOXIDE (CO) GAS CONCENTRATION LEVELS CONTINUE TO RISE & ANY SENSOR

DETECTS 100PPM GAS, W/ VENTILATION CONTACTS CONTINUING TO OPERATE, THE UNIT AUDIBLE

ALARM SOUNDS & HIGH ALARM INDICATOR LIGHTS ON THE CENTRAL CONTROLLER DISPLAY.

SEQUENCE OF OPERATIONS - WAREHOUSE

1. EXHAUST FAN EF-1's SHALL BE INTERLOCKED W/ FRESH AIR & EXHAUST AIR DAMPERS MD-1 & MD-2 AS

WELL AS THE GAS DETECTION SYSTEM (SEE "SEQUENCE OF OPERATIONS - GAS DETECTION SYSTEMS")

2. EF-1 SHALL BE CONTROLLED BY AN "HOA" SWITCH. EF-1 SHALL BE ENERGIZED WHEN MD-1 & MD-2

ARE COMPLETELY OPENED AS SENSED BY THEIR END SWITCHES.

SEQUENCE OF OPERATIONS - FABRICATION SHOP

1. EXHAUST FAN EF-2 SHALL BE CONTROLLED BY A SINGLE THROW SWITCH AND SHALL BE INTERLOCKED

W/ FRESH AIR DAMPER MD-3.

SEQUENCE OF OPERATIONS - ELECTRICAL ROOM

1. EF-3 SHALL BE CONTROLLED BY A REVERSE ACTING THERMOSTAT. EF-3 SHALL BE ENERGIZED WHEN

THE THERMOSTAT READS 35°C.

PUMP SCHEDULE - ELECTRICAL

TAG # DESCRIPTION MAKE MODEL # MOTOR

SUBMERSIBLE WASTE

WATER SUMP PUMP

SP-1

HEAD

Meters (Feet)

FLOW

L/s (gpm)

ZOELLER 49

1/4hp (0.19 kW) 3 (10) 1.6 (25)

MCA (AMPS) MOCP (AMPS)VOLTAGE

120/1/60

4.0 15

REMARKS

INSTALL PER MANUFACTURERS INSTALLATION

INSTRUCTIONS

PREASSEMBLED WASTE

WATER SUMP PUMP SYSTEM

SP-2 ZOELLER 900-0002

3/10hp (0.22 kW) 3 (10) 2.2 (35)120/1/60

9.7 15

INSTALL PER MANUFACTURERS INSTALLATION

INSTRUCTIONS

NOTE: EQUIPMENT OF EQUAL PERFORMANCE IS ACCEPTABLE

DIFFUSER, REGISTER & GRILLE SCHEDULE

TAG DESCRIPTION

SUPPLY AIR GRILLEA

CFM

400

MAKE

PRICE

MODELSIZE

16" x 6" 510

EXHAUST AIR GRILLEB

300 PRICE10" x 10" 530

NOTE: WHEN COGEN UNIT IS RUNNING

HWH.1 AND F.1 DO NOT DEMAND GAS.

PLUMBING EQUIPMENT SCHEDULE

TAG ID DESCRIPTION

MANUFACTURER /

MODEL

S.1

STAINLESS STEEL SERVICE SINK - S.S. TUBULAR LEGS W/ ADJUSTABLE

FEET, 2 HOLES 8" ON CENTRE, BACKSPLASH MOUNTED TWO HANDLE

MANUAL FAUCET W/ SPRAY HOSE, VACUUM BREAKER, BUCKET HOOK AND

PROJECTION SPOUT W/

3

4

" HOSE ADAPTER (MF'R: CHICAGO FAUCETS,

MODEL 509-GCLAB-ES) AND ALL INSTALLATION/MOUNTING HARDWARE

NOTE: EQUIPMENT OF EQUAL PERFORMANCE IS ACCEPTABLE

FRANKE

SSL2418-1/2

1

PROJECT NUMBER

DRAWN CHECKED

SCALEDATE

FILE NAME

DRAWING

DATEDESCRIPTIONREV.

This drawing is the property ofSPH Engineering Inc. and is not tobe copied or distributed for anyreason or by any means withoutthe permission of the owner.

DRAWING

PROJECT

CLIENT

FAX: 519-539-5775TEL: 519-539-5700

SPH ENGINEERING INC.REAL WORLD ENGINEERING SOLUTIONS

N4S 8V8WOODSTOCK, ONTARIO

UNIT #165 SPRINGBANK AVE. N.

18134GMImainM4

STAMP NORTH ARROW

DATE

ISSUED FORPRELIMINARYCLIENT REVIEWSITE PLAN APPROVAL

BUILDING PERMITTENDERCONSTRUCTION

2018-10-01

.

Toll Free: 1-877-392-9766

Tel: (519) 842-4392

49 North Street East , Tillsonburg , ON N4G 1B4

email:[email protected]

Fax: (519) 688-2470

CONSTRUCTION LTD.

Grassmere

ww

w.g

rass

me

re.c

om

design-build construction services

R. W. SPENCER

RE

G

IS

T

E

R

E

D

P

R

O

F

ESS

IO

N

A

L

E

N

G

IN

EE

R

P

R

O

V

I

N

C

E

OF

O

N

T

A

R

I

O

100191633

2018-10-01

2018-04-12

GG RS

AS NOTED

18134

MECHANICAL LEGENDSAND SCHEDULES

PROPOSED ADDITIONSGMI BUILDING

BEARDS LANE, WOODSTOCK, ON

M3

N

Page 5: PROFESIO D - grassmere.comgrassmere.com/wp-content/uploads/2018/10/M-E-Drawings-revised-… · profesio n a l e n g i n e e r p r o v in ceofon ta rio 100191633 2018-10-01 2018-04-12

GENERAL SPECIFICATIONS

THE SCOPE OF WORK SHALL INCLUDE ALL LABOUR, MATERIALS, EQUIPMENT, AND TOOLS

REQUIRED FOR A COMPLETE AND WORKING INSTALLATION AS DETAILED WITHIN THESE

DRAWINGS AND SPECIFICATIONS TO THE SATISFACTION OF THE ENGINEER.

SECTIONS OF THESE SPECIFICATIONS ARE NOT INTENDED TO DELEGATE FUNCTIONS OR TO

DELEGATE WORK AND SUPPLY TO ANY SPECIFIC TRADE.

THE DRAWINGS AND SPECIFICATIONS SHALL BE READ IN CONJUNCTION WITH BASE

BUILDING DRAWINGS AND SPECIFICATIONS. THE BASE BUILDING STANDARDS SHALL FORM

THE BASIS FOR THIS CONSTRUCTION.

PROVIDE ALL WORK IN ACCORDANCE WITH THE REQUIREMENTS OF ALL GOVERNING

AUTHORITIES, AND LOCAL BY-LAWS.

CONFORM TO THE BEST MODERN PRACTICES OF WORKMANSHIP AND INSTALLATION

METHODS AND EMPLOY ONLY SKILLED TRADESPEOPLE WORKING UNDER THE DIRECTION OF

FULLY QUALIFIED PERSONNEL.

APPLY FOR, OBTAIN, AND PAY FOR ALL PERMITS, LICENCES, INSPECTIONS, EXAMINATIONS

AND FEES REQUIRED PRIOR TO COMMENCEMENT OF CONSTRUCTION.

VISIT AND INSPECT THE SITE OF THE WORK TO VERIFY LOCATION AND ELEVATION OF

EXISTING SERVICES, INCLUDING LOCATIONS OF EXISTING CAPPED SERVICES, WHICH MAY

AFFECT THE TENDER AND WORK OF THIS DIVISION (ELECTRICAL, WATER, SANITARY,

DUCTWORK ETC.) BEFORE SUBMISSION OF TENDER AND PROCEEDING WITH WORK. ALLOW

FOR ANY RE-ROUTING OF EXISTING AND/OR NEW SERVICES AND EQUIPMENT AS REQUIRED

TO AVOID INTERFERENCES IN TENDER PRICE.

SHOULD ANY DISCREPANCY APPEAR BETWEEN THE DRAWINGS AND SPECIFICATIONS, WHICH

LEAVE THE CONTRACTOR IN DOUBT AS TO THE TRUE INTENT AND MEANING OF THE PLANS,

AND SPECIFICATIONS, THE CONTRACTOR SHALL OBTAIN A RULING FROM THE ENGINEER IN

WRITING BEFORE SUBMITTING A TENDER. REPORT TO THE ENGINEER ALL AMBIGUITIES,

DISCREPANCIES, OMISSIONS, ERRORS, DEPARTURES FROM BUILDING BYLAWS AND/OR

FROM GOOD PRACTICE. IF THIS IS NOT DONE IT WILL BE ASSUMED THAT THE MOST

EXPENSIVE ALTERNATIVE HAS BEEN INCLUDED IN THE TENDER PRICE. FOR ANY RULING TO

BECOME BINDING, THE ENGINEER MUST ISSUE THE NEW DIRECTION IN A PUBLISHED FORM.

ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE APPROVED SCHEDULE TO MEET THE

PROJECT COMPLETION DATE AND ALL SPECIFIED INTERIM SCHEDULES.

ALL SHUTDOWNS OF ANY PORTION OF THE EXISTING BASE BUILDING SYSTEMS SHALL BE

PERFORMED BY THE OWNER'S BUILDINGS OPERATIONS STAFF AND/OR COORDINATED WITH

THE OWNER FOR THE TIME AND DURATION OF INTERRUPTIONS AND ADHERE TO THE

LANDLORD'S INSTRUCTIONS IN THIS REGARD. CAREFULLY SCHEDULE DISRUPTIONS TO

KEEP "DOWN TIME" TO A MINIMUM. COST FOR SHUTDOWNS, DRAINING AND REFILLING OF

BASE BUILDING SYSTEMS SHALL BE INCLUDED IN THE TENDER PRICE.

IN ALL AREAS REQUIRING CORE DRILLING THROUGH EXISTING FLOOR SLAB FOR

MECHANICAL SERVICES, ETC. ALLOW FOR ALL NECESSARY RADIOGRAPHY TO LOCATE

HIDDEN ELECTRICAL SERVICES, STRUCTURAL REINFORCING, ETC., AND INCLUDE ALL COSTS

IN TENDER PRICE. COORDINATE THIS WORK WITH LANDLORD AND/OR TENANT

COORDINATOR FOR TIME, DURATION AND LOCATIONS REQUIRED, AND ADHERE TO THE

LANDLORD'S REQUIREMENTS. SUBMIT CORE DRILLING PLAN TO BASE BUILDING

STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO COMMENCEMENT OF WORK.

CHECK AND VERIFY LOCATION OF EXISTING MECHANICAL AND ELECTRICAL INTERFERENCES

IN CEILING SPACE OF FLOOR BELOW AND/OR BELOW FLOOR SLAB IN ALL AREAS REQUIRING

CORE DRILLING AND/OR CUTTING OF FLOOR SLAB ON GRADE AND ENSURE COMPATIBILITY

OF AREA BELOW TO THE SATISFACTION OF THE LANDLORD.

INCLUDE COST OF PREMIUM TIME IN TENDER PRICE FOR WORK DURING NIGHTS,

WEEKENDS, OR OTHER TIME OUTSIDE NORMAL WORKING HOURS NECESSARY TO MAINTAIN

ALL MECHANICAL SERVICES IN OPERATION, AND TO COMPLETE THE WORK.

CUTTING, CORING, DRILLING, PATCHING, FLASHING, REPAIRS AND CLEAN-UP OF EXISTING

SURFACES REQUIRED AS A RESULT OF THE REMOVAL AND/OR RELOCATION OF EXISTING

EQUIPMENT AND PIPING, AND/OR INSTALLATION OF NEW EQUIPMENT AND PIPING TO BE

INCLUDED IN TENDER PRICE. EMPLOY AND PAY APPROPRIATE SUB-TRADE WHOSE WORK IS

INVOLVED, FOR CARRYING OUT WORK DESCRIBED ABOVE.

SUBMIT SHOP DRAWINGS FOR ALL ITEMS SPECIFIED. FOR EQUIPMENT, PROVIDE

PERFORMANCE, PHYSICAL AND OPERATING DATA AS DESCRIBED IN THE SPECIFICATIONS

AND LISTED IN EQUIPMENT SCHEDULES. PROVIDE PERFORMANCE CURVES FOR ALL PUMPS

AND FANS. INCLUDE SOUND AND VIBRATION DATA FOR ALL EQUIPMENT SUCH AS FANS,

VAV TERMINALS AND CHILLERS.

DURING PROGRESS OF WORK, SUBSTITUTE PRODUCTS WILL ONLY BE CONSIDERED WHEN

TENDERED PRODUCTS BECOME UNOBTAINABLE AND WRITTEN PROOF IS SUBMITTED. ALL

ALTERNATE ITEMS SUBMITTED FOR CONSIDERATION MUST NOT EXCEED AVAILABLE SPACE

LIMITATIONS.

EQUIPMENT LISTED AS “EQUAL” IN SPECIFICATIONS OR SUBMITTED AS EQUAL BY THE

CONTRACTOR MUST MEET ALL SPACE REQUIREMENTS, SPECIFIED CAPACITIES AND MUST

HAVE EQUIPMENT CHARACTERISTICS OF SPECIFIED EQUIPMENT AS INTERPRETED BY

ENGINEER. INSTALL EQUIPMENT IN STRICT ACCORDANCE WITH MANUFACTURER'S

PUBLISHED RECOMMENDATIONS.

THE ARCHITECT/INTERIOR DESIGNER AND ENGINEER MUST PROVIDE ACCEPTANCE OF ANY

PRODUCT AS EQUAL BEFORE IT IS ALLOWED TO BE USED ON THIS PROJECT.

ALL ADDITIONAL COSTS FOR MECHANICAL, ELECTRICAL, STRUCTURAL AND ARCHITECTURAL

REVISIONS REQUIRED TO INCORPORATE MATERIALS SUBSTITUTED BY CONTRACTOR SHALL

BE RESPONSIBILITY OF THIS CONTRACTOR. MAKE REVISIONS TO RECORD DRAWINGS

INCORPORATING ALL ALTERNATES AND/OR SUBSTITUTIONS AND ALL RELATED CHANGES.

INSTALL ALL CONCEALED MECHANICAL EQUIPMENT REQUIRING ADJUSTMENT OR

MAINTENANCE IN LOCATIONS EASILY ACCESSIBLE THROUGH ACCESS PANELS AND DOORS.

INSTALL SYSTEMS AND COMPONENTS TO RESULT IN A MINIMUM NUMBER OF ACCESS

PANELS.

PROVIDE ALL ACCESS DOORS IN CEILINGS OR WALLS WHERE SHOWN AND/OR REQUIRED

FOR PROPER SERVICING OF EQUIPMENT. SIZE, FINISH, TYPE, AND FINAL LOCATION TO

COMPLY WITH ARCHITECT/INTERIOR DESIGNER'S APPROVAL. ACCESS DOORS IN RATED

CEILINGS OR WALLS SHALL BE ULC APPROVED FOR THE APPLICATION.

PROVIDE THE OWNER WITH A WRITTEN WARRANTY, FOR ALL LABOUR, MATERIALS, AND

EQUIPMENT IN THIS CONTRACT, FOR A PERIOD OF ONE YEAR COMMENCING AT SUCH TIME

AS THE OWNER, OR THEIR REPRESENTATIVE, DEEMS THE WORK ACCEPTABLE.

TESTING AND COMPLETION OF CONTRACT

THE CONTRACTOR SHALL BE RESPONSIBLE TO TEST AND RUN AND COMMISSION ALL

EQUIPMENT. HIRE AND PAY FOR THE EQUIPMENT MANUFACTURER'S REPRESENTATIVE

TO START-UP ALL EQUIPMENT AND CHECK OUT ALL ASSOCIATED CONTROLS AND SAFETY

CUTOUTS, THIS INCLUDES, THERMOSTATS, OUTDOOR AIR DAMPERS, FIRE STATS,

EXHAUST FAN INTERLOCKS, ETC. THIS WORK SHALL BE COMPLETE AND ANY

DEFICIENCIES RECTIFIED PRIOR TO NOTIFYING THE BALANCING COMPANY THAT THE

SYSTEMS ARE READY TO BE BALANCED.

ALL SYSTEMS SHALL BE COMPLETE, TESTED AND READY FOR USE, WITH ALL EQUIPMENT

AND CONTROLS FUNCTIONING CORRECTLY.

SUBMIT ALL CERTIFICATES OF INSPECTION AND TEST RESULTS TO THE OWNER FOR

REVIEW.

A CLEAN, UNDAMAGED SET OF CONTRACT DRAWINGS INCLUDING COORDINATION

DRAWINGS AND SHOP DRAWINGS SHALL BE KEPT AT THE JOB SITE AS AS-BUILT RECORD

DOCUMENTS. MARK RECORD SETS IN A CLEAR, LEGIBLE MANNER, USING RED INK (NO

PENCILS); TO SHOW THE ACTUAL INSTALLATION, WHERE THE INSTALLATION VARIES

FROM THE WORK AS ORIGINALLY SHOWN. MARK ALL DRAWINGS NECESSARY TO SHOW

CONDITIONS FULLY AND ACCURATELY. GIVE PARTICULAR ATTENTION TO CONCEALED

ELEMENTS THAT WOULD BE DIFFICULT TO MEASURE AND RECORD AT A LATER DATE.

ASSEMBLE TWO (2) MANUALS, EACH CONTAINING DATA SHEETS, BROCHURES,

OPERATING, MAINTENANCE, RECOMMENDED SPARE PARTS, LUBRICATING

INSTRUCTIONS, WRITTEN WARRANTY, REVIEWED AIR AND WATER BALANCING REPORTS,

AND A COMPLETE SET OF REVIEWED SHOP DRAWINGS AND BIND IN HARD

COVER. IDENTIFY COVER “OPERATION AND MAINTENANCE MANUAL”. MANUALS SHALL

BE SEPARATED WITH DIVIDERS IN LOGICAL SECTIONS AND VOLUMES.

PROVIDE A COMPLETE COST BREAKDOWN OF ALL MATERIALS, EQUIPMENT AND LABOUR

COSTS ASSOCIATED WITH EACH SUBMISSION FOR EXTRA OR DELETED WORK.

IDENTIFY EACH PIPED AND DUCTED SERVICE SHOWING NAME AND SERVICE, INCLUDING

TEMPERATURE AND PRESSURE WHERE RELEVANT, AND WITH DIRECTIONAL ARROWS TO

INDICATE FLOW. LOCATE IDENTIFICATION AND FLOW ARROWS NOT MORE THAN 3M (10

FEET) AND AT EACH CHANGE IN THE DIRECTION OF THE PIPE AND AT TAKE-OFFS. USE

WORDING INDICATED ON THE MECHANICAL LEGEND. USE 50MM (2”) HIGH STENCIL

LETTERS.

REUSE EXISTING MATERIALS AND EQUIPMENT WHEREVER POSSIBLE AND PROVIDE NEW

ONLY WHERE REQUIRED AND AS SPECIFIED TO ENSURE A COMPLETE INSTALLATION.

ALL EQUIPMENT, MATERIALS AND ASSOCIATED CONTROLS NOT USED IN THIS CONTRACT

SHALL BE RETURNED TO THE LANDLORD/OWNER.

HVAC DUCTWORK AND FITTINGS

ALL DUCTWORK AND HANGERS SHALL BE FABRICATED IN ACCORDANCE WITH THE

LATEST ASHRAE AND SMACNA RECOMMENDATIONS.

NOTE THAT DIMENSIONS ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS. WHERE

ACOUSTIC INSULATION IS INSTALLED, INCREASE DIMENSIONS ACCORDINGLY.

PROVIDE FLEXIBLE CONNECTORS BETWEEN ALL AIR HANDLING EQUIPMENT AND

ADJACENT DUCTWORK. FLEXIBLE CONNECTIONS SHALL CONSIST OF A

PRE-ASSEMBLED UNIT COMPLETE WITH 75MM (3”) LONG GALVANIZED DUCT

CONNECTOR AND 150MM (6”) WIDE NEOPRENE FLEXIBLE CONNECTOR EQUAL TO

DURO DYNE NEOPRENE.

FLEXIBLE DUCTS SHALL BE FLEXMASTER TRIPLE LOCK MODEL #T/L OR APPROVED

EQUAL, SPIRAL WOUND ALUMINUM STRIP WITH AIR TIGHT AND LEAK-PROOF

TRIPLE LOCK SEAM. DUCTING SHALL CONFORM TO NFPA 90A AND UL-181.

FLEXIBLE DUCTS SHALL BE OF SIZE EQUAL TO DIFFUSER NECK SIZE. DO NOT

RESTRICT DUCT FREE AREA. USE GEAR CLAMPS FOR SECURING FLEXIBLE DUCTS

TO RIGID DUCT CONNECTIONS SUCH AS SPIN-IN FITTINGS, ETC. AND NECKS OF

DIFFUSERS AND SEAL AIR TIGHT WITH DURO-DYNE DUCT SEALER. ROUND

FLEXIBLE DUCTS SHALL BE INSTALLED AS ONE CONTINUOUS PIECE, MAXIMUM

1.5M (5') LONG. REMAINDER SHALL BE ROUND RIGID DUCT. JOINING OF

FLEXIBLE DUCTS IS NOT PERMITTED.

SEAL ALL JOINTS IN SUPPLY, RETURN AND EXHAUST DUCTWORK WITH

DURO-DYNE WATER-BASED HIGH VELOCITY DUCT SEALER OR EQUIVALENT

MEETING REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION AND SMACNA

SEAL CLASS A.

FINAL LOCATION OF NEW SUPPLY AIR DIFFUSERS, BOOTS, LIGHT TROFFERS,

REGISTERS, RETURN AND EXHAUST AIR GRILLES SHALL BE COORDINATED WITH

THE LATEST ARCHITECTURAL AND ELECTRICAL REFLECTED CEILING PLANS.

PROVIDE FIRE DAMPERS WHERE SHOWN ON DRAWING AND/OR WHERE REQUIRED

BY LOCAL AUTHORITIES AND/OR APPLICABLE CODES IN DUCT SECTIONS

COMPLETE WITH APPROVED ACCESS DOORS.

WHERE TRANSFER AND/OR RETURN AIR OPENINGS ARE NOTED ON THE

DRAWINGS (WITHOUT DUCTWORK/DIFFUSERS), THE MECHANICAL CONTRACTOR

IS RESPONSIBLE TO PROVIDE THE LAYOUT TO THE GENERAL TRADES. THIS

CONTRACTOR SHALL CO-ORDINATE AND VERIFY THAT THE REQUIRED NUMBER

AND SIZE OF OPENINGS HAVE BEEN PROVIDED.

PROVIDE NEW BALANCING DAMPERS FOR ALL DUCT BRANCHES, AND IN ALL

LOCATIONS NECESSARY FOR BALANCING THE AIR SYSTEMS, WITH SUITABLE

MEANS OF CEILING ACCESS. PROVIDE VOLUME DAMPERS FOR ALL NEW SUPPLY

AIR DIFFUSERS AND REGISTERS.

TEST, BALANCE AND ADJUST ALL AIR TO OBTAIN THE DESIGN AIR QUANTITIES

AND TEMPERATURE RISES/DROPS ACROSS TERMINAL HEATING/COOLING

ELEMENTS. MARK THE FINAL BALANCE POSITION ON ALL BALANCING DAMPERS

AND ADJUSTABLE AIR TURNING DEVICES AND BALANCE FITTINGS. SUBMIT AIR

SYSTEM TEST AND BALANCE REPORT IN TRIPLICATE TO THE ENGINEER AND

LANDLORD. INDICATE ALL TEST RESULTS INCLUDING COIL ENTERING AND

LEAVING AIR TEMPERATURES, CLOSEST AND FURTHEST OUTLET SUPPLY AIR

TEMPERATURES AND AVERAGE ROOM TEMPERATURES FOR ALL AIR SYSTEMS.

THIS WORK SHALL BE PERFORMED BY A TESTING AND BALANCING CONTRACTOR

WHO IS A MEMBER OF AABC OR NEBB AND APPROVED BY THE LANDLORD, OR

WHEN REQUIRED, BY THE LANDLORD'S TESTING AND BALANCING CONTRACTOR.

IN AREAS WITH DRYWALL CEILINGS, THIS WORK SHALL BE DONE PRIOR TO

ENCLOSING OF CEILING SPACE.

INCLUDE EXTENDED SERVICE OF 90 DAYS, AFTER COMPLETION OF TEST AND

BALANCE WORK, DURING WHICH TIME THE ENGINEER, AT HIS DISCRETION, MAY

REQUEST RE-CHECKING OR RE-SETTING OF ANY SYSTEMS AND/OR EQUIPMENT IN

THE TEST REPORT FOR A MAXIMUM PERIOD OF EIGHT (8) HOURS OF SITE TIME.

ADJUST AND/OR REPLACE EXISTING AIR HANDLING UNIT FAN BELTS, AND

SHEAVES AS REQUIRED TO OBTAIN THE REQUIRED DESIGN SUPPLY AIR

QUANTITIES INDICATED ON PLANS.

MODIFY HVAC DUCTWORK TO SUIT SITE CONDITIONS. MAINTAIN EQUAL CROSS

SECTIONAL AREA AT ALL SECTIONS TO ENSURE DESIRED AIR FLOWS.

HVAC CONTROLS

ALL CONTROLS SHALL BE SUPPLIED AND INSTALLED BY THE MECHANICAL

CONTRACTOR AND APPROVED BY OWNER.

PROVIDE AND INSTALL CONDUIT, WIRE, ELECTRIC RELAYS, CONNECTIONS AND

OTHER DEVICES REQUIRED FOR CONTROL CIRCUIT WIRING, WHETHER LINE

OR LOW VOLTAGE, FOR A COMPLETE AND OPERATING CONTROL SYSTEM. THE

CONTROLS CONTRACTORS SHALL EITHER USE THEIR OWN ELECTRICIANS, OR

USE AN ELECTRICAL SUB-TRADE ACCEPTABLE TO ENGINEER TO SUPPLY AND

INSTALL ALL CONDUIT AND WIRING FOR SYSTEMS AS SPECIFIED.

LOCATIONS OF TEMPERATURE SENSORS ARE INDICATED ON THE DRAWINGS.

MOUNTING HEIGHT OF OCCUPANT ADJUSTABLE THERMOSTATS SHALL BE

1400mm TO 1500mm FROM FINISHED FLOOR. MOUNTING HEIGHT OF

NON-ADJUSTABLE THERMOSTATS SHALL BE 1500 MM [5 FT. 0 IN.] FROM

FINISHED FLOOR. CONFIRM FINAL LOCATIONS WITH THE

ARCHITECT/INTERIOR DESIGNER BEFORE INSTALLATION. AVOID DRAFTS,

STAGNANT AIR, EFFECTS OF OTHER SYSTEMS, OBSTRUCTED LOCATION, AND

LOCATION EXPOSED TO DAMAGE.

SHOP DRAWINGS SHALL INCLUDE A CONTROL DIAGRAM INDICATING HOW

CONTROLS ARE ELECTRICALLY CONNECTED FOR EACH SYSTEM, AND

EQUIPMENT LIST AND MANUFACTURERS DATA SHEETS AND A DESCRIPTION OF

THE CONTROL SEQUENCE FOR EACH SYSTEM.

THE OPERATING AND MAINTENANCE MANUAL SHALL CONTAIN AS BUILT SHOP

DRAWINGS AND OPERATING AND MAINTENANCE INSTRUCTIONS FOR CONTROL

EQUIPMENT.

PLUMBING

INSTALL ALL PIPING IN THE BEST WORKMANLIKE MANNER AND IN ACCORDANCE

WITH THE BEST PRACTICES OF THE TRADE.

PROVIDE ALL BRONZE BALL TYPE ISOLATING VALVES ON MAIN AND/OR BRANCH

LINES AND FOR EACH INDIVIDUAL PIECE OF EQUIPMENT SERVED WITH HOT AND

COLD WATER LINES. ALL VALVES SHALL BE SUITABLE FOR THE OPERATING

PRESSURE OF THE SYSTEM IN WHICH THEY ARE INSTALLED.

PROVIDE DI-ELECTRIC COUPLINGS/UNIONS WHERE COPPER PIPING CONNECTS TO

FERROUS METAL EQUIPMENT SUCH AS STEEL STORAGE TANKS, PRV'S, ETC. AND

STEEL, BLACK IRON, CAST IRON OR GALVANIZED IRON PIPING.

FINAL LOCATION OF ALL NEW PLUMBING FIXTURES SHALL BE COORDINATED ON

SITE WITH ALL TRADES. REFER TO ARCHITECTURAL/INTERIOR DESIGNER

DRAWINGS AND DETAILS FOR EXACT LOCATION OF PLUMBING FIXTURES.

PROVIDE NEW PLUMBING FIXTURES WHERE INDICATED ON PLAN. ALL FIXTURES

SHALL BE OF FIRST QUALITY, BEST GRADE OBTAINABLE, CLEANED AND IN

PERFECT CONDITION FOR THE OWNER TAKEOVER. FIXTURES SHALL BE PIPED

COMPLETE IN A FIRST CLASS MANNER WITH ALL NECESSARY APPURTENANCES

FOR A COMPLETE FIXTURE IN EVERY RESPECT. INSTALL ALL COMPONENTS IN

STRICT ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.

PROVIDE A TRAP SEAL PRIMER ON ALL NEW FLOOR DRAINS, FUNNEL FLOOR

DRAINS AND HUB DRAINS. FOR INDIVIDUAL OR REMOTE DRAINS, PROVIDE

PRECISION PLUMBING PRODUCTS INC. MODEL PO-500 AUTOMATIC TRAP SEAL

PRIMER VALVE, WITH 12MM (½") NPT (M TO F) CONNECTIONS WITH STRAINER

AND INTEGRAL BACK FLOW PREVENTER AND VACUUM BREAKER. COMPLETE WITH

YS-8 SUPPLY TUBE. FOR INSTALLATIONS WITH LARGE NUMBERS OF TRAPS IN

CLOSE PROXIMITY, PROVIDE ELECTRONIC TRAP PRIMING SYSTEMS EQUIVALENT

TO P.P.P. INC. PRIME-TIME™ ELECTRONIC TRAP PRIMER.

DISCONNECT AND CAP ALL EXISTING DRAIN, VENT, HOT AND COLD WATER PIPES

NOT USED IN THIS CONTRACT AT FLOOR, WALL OR CEILING. PROVIDE NEW

PIPING ONLY WHERE NECESSARY AND REUSE EXISTING WHEREVER POSSIBLE AND

WHERE CONDITIONS PERMIT.

INSULATION - PLUMBING SERVICES

PROVIDE INSULATION MATERIALS WITH A MAXIMUM THERMAL CONDUCTIVITY OF

{0.036 W/M.ºC} [0.25 BTU.IN/(HR.FT2ºF] AT {38ºC} [100ºF] MEAN TEMPERATURE.

COVER ALL DOMESTIC HOT AND COLD WATER, CONDENSATE AND STORM DRAIN

PIPING WITH PRE-MOLDED LOW PRESSURE GLASS FIBER INSULATION. FOR

DOMESTIC COLD WATER, CONDENSATE, AND STORM DRAIN PIPING USE FACTORY

APPLIED PAPER FREE ASJ VAPOUR BARRIER JACKET.

ACCEPTABLE MANUFACTURERS: OWENS CORNING PIPE INSULATION, JOHNS

MANVILLE FIBERGLAS PIPE INSULATION, MANSON FIBERGLAS PIPE INSULATION

OR KNAUF PIPE INSULATION.

INSULATION THICKNESS SHALL BE AS FOLLOWS;

DOMESTIC COLD WATER:ALL PIPE SIZES - 25MM (1”) INSULATION

DOMESTIC HOT WATER: UP TO 1” - 25MM (1”) INSULATION

1” AND LARGER - 40MM (1-1/2”) INSULATION

COVER ALL FITTINGS, VALVES, WATER METERS AND APPURTENANCES CONNECTED

TO HOT AND COLD WATER PIPING AND CONDENSATE DRAIN PIPING WITH

FABRICATED MITERED OR PREFORMED SECTIONS OF SPECIFIED INSULATION OR

ARMAFLEX WITH THICKNESS SHOWN ABOVE. SEAL INSULATION FOR COLD

WATER FITTINGS WITH A VAPOUR BARRIER ADHESIVE AND REINFORCE WITH

GLASS OPEN WEAVE FIBER TAPE AND FINISH SMOOTH WITH A COAT OF MASTIC.

WHERE INSULATED PIPING IS EXPOSED (AREAS WITHOUT CEILINGS,

MECHANICAL/COMPUTER ROOMS, ETC.) PROVIDE PVC JACKET AND FITTING

COVERS INSTALLED AS PER MANUFACTURER'S INSTRUCTIONS, AND CONFORMING

TO THE SPECIFIED FLAME SPREAD/SMOKE DEVELOPED RATING.

WASTE AND VENT PIPING SYSTEMS

CAST IRON SOIL PIPE COMPONENTS:

PIPE: CAST IRON SOIL PIPE TO CAN/CSA-B70.

MECHANICAL JOINT COMPONENTS: HUBLESS FITTINGS, ELASTOMERIC

GASKETS AND STAINLESS STEEL MECHANICAL JOINT COUPLINGS TO

CAN/CSA-B70.

COPPER TUBE COMPONENTS.

PIPE: DWV COPPER TUBE: TO ASTM B306.

JOINT AND FITTING COMPONENTS.

.1 WROUGHT COPPER FITTINGS: TO ANSI B16.29.

.2 CAST COPPER, BRASS AND BRONZE FITTINGS: TO ANSI B16.23.

.3 SOLDER JOINTS: TO ASTM B32.

.4 BRAZED JOINTS: TO ASTM B664.

ABS PIPE COMPONENTS.

PIPE: ABS PLASTIC PIPE: TO CAN/CSA-B181.1.

JOINT AND FITTING COMPONENTS:

.1 FITTINGS: ABS FITTINGS TO CAN/CSA-B181.1.

.2 ABS SOLVENT CEMENT: TO ASTM D2235.

.3 ABS - PVC SOLVENT CEMENT: TO ASTM D3138.

PVC PIPE COMPONENTS:

PIPE: PVC PLASTIC PIPE TO CAN/CSA-B181.2.

.JOINT AND FITTING COMPONENTS:

.1 FITTINGS: PVC FITTINGS TO CAN/CSA-B181.2.

.2 PVC SOLVENT CEMENT: TO ASTM D2564.

.3 ABS-PVC SOLVENT CEMENT: TO ASTM D3138.

ALL DOMESTIC WATER PIPE, JOINTS, AND FITTINGS

.1 ALL PIPES PENETRATING FIRE RATED WALL ASSEMBLIES TO BE

MINIMUM REGULAR COPPER PIPE OR TYPE L COPPER TUBING.

.2 COPPER PIPE: ASTM B42 WITH ASME B16.22 WROUGHT COPPER OR

ASME B16.18 CAST COPPER, BRASS AND BRONZE FITTINGS, ASTM

B32 SOLDER.

.3 COPPER TUBE: ASTM B88 WITH ASME B16.22 WROUGHT COPPER

OR ASME B16.18 CAST COPPER, BRASS AND BRONZE FITTINGS,

ASTM B32 SOLDER.

.4 CPVC SCHEDULE 40 PIPE: ASTM F441/F441M WITH ASTM F438

SOCKET, ASTM F439 SOCKET, OR ASTM F437 THREADED

TYPE FITTINGS.

.5 CPVC SYSTEM: ASTM D2846/D2846M, SDR 11, PIPE OR TUBE AND

SOCKET FITTINGS.

.6 PEX DISTRIBUTION SYSTEM: ASTM F877, SDR 9 TUBING ASTM

F1807, METAL-INSERT TYPE WITH COPPER CRIMP RINGS AND

MATCHING PEX TUBE DIMENSIONS.

.7 PROVIDE AND INSTALL PEX TUBING EQUIVALENT TO 'Wirsbo hePEX'

TUBING COMPLETE WITH OXYGEN DIFFUSION BARRIER AND

INSTALLED AS PER CAN/CSA-137.5 STANDARD.

.8 ACR COPPER: ASTM B280.

.9 DWV COPPER: ASTM B306.

JOINTS AND FITTINGS:

.1 WROUGHT COPPER FITTINGS: ASME B16.22.

.2 CAST COPPER, BRASS AND BRONZE FITTINGS: ASME B16.18.

.3 SOLDER JOINTS: ASTM B32.

INSTALL ALL GAS APPLIANCES AND PIPING IN ACCORDANCE WITH

CSAB149.1 NATRUAL GAS AND PROPANE INSTALLATION CODE.

INSTALL ALL GAS APPLIANCES IN ACCORDANCE WITH

MANUFACTURER'S INSTRUCTIONS

GAS APPLIANCES/PIPING

PROJECT NUMBER

DRAWN CHECKED

SCALEDATE

FILE NAME

DRAWING

DATEDESCRIPTIONREV.

This drawing is the property ofSPH Engineering Inc. and is not tobe copied or distributed for anyreason or by any means withoutthe permission of the owner.

DRAWING

PROJECT

CLIENT

FAX: 519-539-5775TEL: 519-539-5700

SPH ENGINEERING INC.REAL WORLD ENGINEERING SOLUTIONS

N4S 8V8WOODSTOCK, ONTARIO

UNIT #165 SPRINGBANK AVE. N.

18134GMImainM4

STAMP NORTH ARROW

DATE

ISSUED FORPRELIMINARYCLIENT REVIEWSITE PLAN APPROVAL

BUILDING PERMITTENDERCONSTRUCTION

2018-10-01

.

Toll Free: 1-877-392-9766

Tel: (519) 842-4392

49 North Street East , Tillsonburg , ON N4G 1B4

email:[email protected]

Fax: (519) 688-2470

CONSTRUCTION LTD.

Grassmere

ww

w.g

rass

me

re.c

om

design-build construction services

R. W. SPENCER

RE

G

IS

T

E

R

E

D

P

R

O

F

ESS

IO

N

A

L

E

N

G

IN

EE

R

P

R

O

V

I

N

C

E

OF

O

N

T

A

R

I

O

100191633

2018-10-01

2018-04-12

GG RS

AS NOTED

18134

MECHANICALSPECIFICATIONS

PROPOSED ADDITIONSGMI BUILDING

BEARDS LANE, WOODSTOCK, ON

M4

N

Page 6: PROFESIO D - grassmere.comgrassmere.com/wp-content/uploads/2018/10/M-E-Drawings-revised-… · profesio n a l e n g i n e e r p r o v in ceofon ta rio 100191633 2018-10-01 2018-04-12

UP

EXISTING LIGHT TO BE

REMOVED

EXISTING LIGHT TO BE

REMOVED

EXISTING LIGHT TO BE

REMOVED

EXISTING LIGHT TO BE

REMOVED

EXISTING SECURITY CAMERA.

RELOCATE TO CLEAR HEIGHT OF

NEW MAINTENANCE SHOP.

EXISTING SECURITY CAMERA TO BE

RELOCATED

SERVICE SWITCH TO BE REMOVED

METERING CABINET TO BE REMOVED

X

X X

E

5a

-3 -2

C0

C4

A

F

Ex

1 2 3

65

D1

A1

10

4

4b4a

B

E

97b

6a

1a

C1

8

C3

8x

Dy

7a 7bb

6

Ey

E

D

C

B

A

98

7654321

MM

RELOCATE POWER SUPPLY

FOR MOTORIZED DAMPER

PROJECT NUMBER

DRAWN CHECKED

SCALEDATE

FILE NAME

DRAWING

DATEDESCRIPTIONREV.

This drawing is the property ofSPH Engineering Inc. and is not tobe copied or distributed for anyreason or by any means withoutthe permission of the owner.

DRAWING

PROJECT

CLIENT

FAX: 519-539-5775TEL: 519-539-5700

SPH ENGINEERING INC.REAL WORLD ENGINEERING SOLUTIONS

N4S 8V8WOODSTOCK, ONTARIO

UNIT #165 SPRINGBANK AVE. N.

18134GMImainM4

STAMP NORTH ARROW

DATE

ISSUED FORPRELIMINARYCLIENT REVIEWSITE PLAN APPROVAL

BUILDING PERMITTENDERCONSTRUCTION

2018-10-01

.

Toll Free: 1-877-392-9766

Tel: (519) 842-4392

49 North Street East , Tillsonburg , ON N4G 1B4

email:[email protected]

Fax: (519) 688-2470

CONSTRUCTION LTD.

Grassmere

ww

w.g

rass

me

re.c

om

design-build construction services

R. W. SPENCER

RE

G

IS

T

E

R

E

D

P

R

O

F

ESS

IO

N

A

L

E

N

G

IN

EE

R

P

R

O

V

I

N

C

E

OF

O

N

T

A

R

I

O

100191633

2018-10-01

2018-04-12

GG RS

AS NOTED

18134

EXISTING/DEMOELECTRICAL LAYOUT

PROPOSED ADDITIONSGMI BUILDING

BEARDS LANE, WOODSTOCK, ON

ED1

N

EXISTING/DEMO ELECTRICAL LAYOUT

SCALE:

3

32

"=1'-0"

Page 7: PROFESIO D - grassmere.comgrassmere.com/wp-content/uploads/2018/10/M-E-Drawings-revised-… · profesio n a l e n g i n e e r p r o v in ceofon ta rio 100191633 2018-10-01 2018-04-12

UP

SOUTH ADDITION

MAINTENANCE SHOP

NORTH

ADDITION

DN

DN

22 2

222

22 2

22

2 2

2 2

2 2 2

2

2

8

8

8

8

X

X X

X

4 4 44

4

444

SUB2-6

SUB2-6

SUB2-6

SUB2-6

SUB1-7,9

SUB1-7,9

SUB1-7,9

SUB1-7,9

SUB1-7,9

SUB1-7,9

SUB1-7,9

SUB1-7,9

SUB1-7,9

SUB1-7,9

SUB1-11,13

SUB1-11,13

SUB1-11,13

SUB1-11,13

SUB1-11,13

SUB1-11,13

SUB1-11,13

SUB1-11,13

SUB1-11,13

SUB2-4

SUB2-4

SUB2-4

PP2-10 PP2-10

PP1-8,10PP1-8,10PP1-8,10

PP1-8,10 PP1-8,10 PP1-8,10PP1-8,10

PP1-8,10

MAINTENANCE SPOT LIGHTS. COORDINATE

EXACT LOCATIONS WITH GMI.

A7

A7

A13

A13

NOTE: EXTEND EXISTING LIGHTING

CIRCUITS TO NORTH ADDITION

5 5

5

7

A-14

6

1

7

A-12

7

A-12

7

A-12

6

7

A-14

1

7

A-14

1

1

6

E

5a

D3

-3 -2-4

C0

C4

A

F

Ex

1

-5

G

2 3

1B

65

D1

A1

10

4

-5

1a-2-3-4

G

F

Ex

D2

C2

A1

4b4a

B

E

97b

6a

1a

C1

8

C3

8x

Dy

7a 7bb

6

Ey

E

D

C

B

A

98

7654321

7

7

A-12

A-12

3

SUB2-11,13

SUB1-11,13

X

SUB2-6

1

1 2 3 4

A

B

3 3 3 3 3

3 3 3 3 3

3 3 3 3 3

3 3 3 3 3

6

6

TP1-8

TP1-8

7

TP1-1,3

7

TP1-1,3

7

TP1-1,3

7

TP1-1,3

TP1-4,6 TP1-4,6 TP1-4,6 TP1-4,6 TP1-4,6

TP1-4,6 TP1-4,6 TP1-4,6 TP1-4,6 TP1-4,6

TP1-4,6 TP1-4,6 TP1-4,6 TP1-4,6 TP1-4,6

TP1-4,6 TP1-4,6 TP1-4,6 TP1-4,6 TP1-4,6

NOTE: BUILDING EXTERIOR LIGHTING TO

BE POWERED FROM EXISTING PANEL A

CIRCUITS AS IDENTIFIED ON DRAWING.

PROJECT NUMBER

DRAWN CHECKED

SCALEDATE

FILE NAME

DRAWING

DATEDESCRIPTIONREV.

This drawing is the property ofSPH Engineering Inc. and is not tobe copied or distributed for anyreason or by any means withoutthe permission of the owner.

DRAWING

PROJECT

CLIENT

FAX: 519-539-5775TEL: 519-539-5700

SPH ENGINEERING INC.REAL WORLD ENGINEERING SOLUTIONS

N4S 8V8WOODSTOCK, ONTARIO

UNIT #165 SPRINGBANK AVE. N.

18134GMImainM4

STAMP NORTH ARROW

DATE

ISSUED FORPRELIMINARYCLIENT REVIEWSITE PLAN APPROVAL

BUILDING PERMITTENDERCONSTRUCTION

2018-10-01

.

Toll Free: 1-877-392-9766

Tel: (519) 842-4392

49 North Street East , Tillsonburg , ON N4G 1B4

email:[email protected]

Fax: (519) 688-2470

CONSTRUCTION LTD.

Grassmere

ww

w.g

rass

me

re.c

om

design-build construction services

R. W. SPENCER

RE

G

IS

T

E

R

E

D

P

R

O

F

ESS

IO

N

A

L

E

N

G

IN

EE

R

P

R

O

V

I

N

C

E

OF

O

N

T

A

R

I

O

100191633

2018-10-01

2018-04-12

GG RS

AS NOTED

18134

NEW LIGHTINGLAYOUT

PROPOSED ADDITIONSGMI BUILDING

BEARDS LANE, WOODSTOCK, ON

E1

N

MAIN BUILDING LIGHTING LAYOUT

SCALE:

1

16

"=1'-0"

DRIVE THROUGH SHELTER LIGHTING LAYOUT

SCALE:

1

16

"=1'-0"

Page 8: PROFESIO D - grassmere.comgrassmere.com/wp-content/uploads/2018/10/M-E-Drawings-revised-… · profesio n a l e n g i n e e r p r o v in ceofon ta rio 100191633 2018-10-01 2018-04-12

UP

SOUTH ADDITION

MAINTENANCE SHOP

NORTH

ADDITION

DN

DN

20A MAINTENANCE

RECEPTACLE.

TYPICAL.

NOTES:

1. RECEPTACLES IN NORTH AND SOUTH ADDITIONS ARE

TO BE MOUNTED 3' A.F.F. UNLESS NOTED OTHERWISE.

2. LIGHTING CONTROLS, FAN CONTROLS, AND GAS

DETECTION CONTROLLER TO BE LOCATED NEXT TO SUB

PANELS.

120V SUBPANEL-SUB 2

600V SUBPANEL-SUB 1

BALER CONTROL PANEL

RUN CONDUIT

THROUGH WALL

RUN CONDUIT

THROUGH WALL

RUN CONDUIT UP WALL AND

ABOVE DOOR OPERATORS

DOOR OPENER

SUB2-8,10,12

DOOR OPENER

DOOR

OPENER

SUB2-8

SUB2-2,4,6

SUB2-1

SUB2-1

SUB2-1

SUB2-1

SUB1-1,3,5

SUB2-1

SUB2-2

SP-1

SUB2-1

SUB2-3

CONTRACTOR TO CONNECT TO

NEAREST RECEPTACLE CIRCUIT

M

MM

SUB2-5,7,9

EF-1

SUB2-5,7,9

EF-1

SUB2-8

SUB2-8

E

5a

D3

-3 -2-4

C0

C4

A

F

Ex

1

-5

G

2 3

1B

65

D1

A1

10

4

-5

1a-2-3-4

G

F

Ex

D2

C2

A1

4b4a

B

E

97b

6a

1a

C1

8

C3

8x

Dy

7a 7bb

6

Ey

E

D

C

B

A

98

7654321

SUB2-12

EBB.1

SUB2-10

RUN CONDUIT AND CONNECT

TO EXISTING SERVICE

GAS DETECTION PANEL

SUB2-14,16,18

WELD RECP.

CONNECT NEW SERVICE TO

EXISTING SPLITTER

1

NOTES:

1. RECEPTACLES IN NORTH AND SOUTH ADDITIONS ARE

TO BE MOUNTED 3' A.F.F. UNLESS NOTED OTHERWISE.

2. LIGHTING CONTROLS, FAN CONTROLS, AND GAS

DETECTION CONTROLLER TO BE LOCATED NEXT TO SUB

PANELS.

PROJECT NUMBER

DRAWN CHECKED

SCALEDATE

FILE NAME

DRAWING

DATEDESCRIPTIONREV.

This drawing is the property ofSPH Engineering Inc. and is not tobe copied or distributed for anyreason or by any means withoutthe permission of the owner.

DRAWING

PROJECT

CLIENT

FAX: 519-539-5775TEL: 519-539-5700

SPH ENGINEERING INC.REAL WORLD ENGINEERING SOLUTIONS

N4S 8V8WOODSTOCK, ONTARIO

UNIT #165 SPRINGBANK AVE. N.

18134GMImainM4

STAMP NORTH ARROW

DATE

ISSUED FORPRELIMINARYCLIENT REVIEWSITE PLAN APPROVAL

BUILDING PERMITTENDERCONSTRUCTION

2018-10-01

.

Toll Free: 1-877-392-9766

Tel: (519) 842-4392

49 North Street East , Tillsonburg , ON N4G 1B4

email:[email protected]

Fax: (519) 688-2470

CONSTRUCTION LTD.

Grassmere

ww

w.g

rass

me

re.c

om

design-build construction services

R. W. SPENCER

RE

G

IS

T

E

R

E

D

P

R

O

F

ESS

IO

N

A

L

E

N

G

IN

EE

R

P

R

O

V

I

N

C

E

OF

O

N

T

A

R

I

O

100191633

2018-10-01

2018-04-12

GG RS

AS NOTED

18134

MAIN BUILDING POWER LAYOUT

PROPOSED ADDITIONSGMI BUILDING

BEARDS LANE, WOODSTOCK, ON

E2

N

MAIN BUILDING POWER LAYOUT

SCALE:

1

16

"=1'-0"

AutoCAD SHX Text
Bale chute
AutoCAD SHX Text
Conveyor
AutoCAD SHX Text
Switch cabinet incl. OP
AutoCAD SHX Text
Control block
AutoCAD SHX Text
Air oil
AutoCAD SHX Text
cooler
AutoCAD SHX Text
Hydraulic power unit
AutoCAD SHX Text
ArnoPress D 150-3
AutoCAD SHX Text
Weighing hopper
AutoCAD SHX Text
1
AutoCAD SHX Text
ADDED EXISTING SPLITTER
AutoCAD SHX Text
2018-10-01
Page 9: PROFESIO D - grassmere.comgrassmere.com/wp-content/uploads/2018/10/M-E-Drawings-revised-… · profesio n a l e n g i n e e r p r o v in ceofon ta rio 100191633 2018-10-01 2018-04-12

PP2

120/208V

PANEL

PP1

347/600V

PANEL

45KVA

TRANSFORMER

600A SPLITTER

100A

DISCONNECT

300A

DISCONNECT

NEW 400A DISCONNECT

IN EXISTING BUILDING

TO BALER

TO EXISTING SPLITTER

IN EXISTING BUILDING

METER

CABINET

MAIN 600A

SERVICE ENTRANCE

SWITCH

TO 120V

SUB PANEL

TO 600V

SUB PANEL

60A

DISCONNECT

1

SEE NEW ELECTRICAL

ROOM LAYOUT DETAILS

MAINTENANCE SHOP

208V AIR

COMPRESSOR

BAND SAWTABLE SAWDRILL PRESS

20A FUTURE TOOLS

WELD REC.

MOUNTED @ WORK

BENCH HEIGHT

MOUNTED @ WORK

BENCH HEIGHT

EF-2

AC.1

F.1

PP2-7 PP2-8 PP2-5 PP2-3 PP2-1

PP2-9,11,13

PP2-6 PP2-6 PP2-6 PP2-6 PP2-6

PP2-6

EF-3

PP2-25

PP2-26

HWT-1 ABOVE

PP2-16

M

PP2-14

PP2-12

PP2-2,4

HRV.1

PP2-24

SP-2

PP2-22

PP2-21,23

PP1-2,4,6

HT.1

1

EyEy

4a4a

4b4b

66a6a 6

1 2 3 4

A

B

TP1

120/208V PANEL

TP1-2 TP1-2

TP1-2 TP1-2

PROJECT NUMBER

DRAWN CHECKED

SCALEDATE

FILE NAME

DRAWING

DATEDESCRIPTIONREV.

This drawing is the property ofSPH Engineering Inc. and is not tobe copied or distributed for anyreason or by any means withoutthe permission of the owner.

DRAWING

PROJECT

CLIENT

FAX: 519-539-5775TEL: 519-539-5700

SPH ENGINEERING INC.REAL WORLD ENGINEERING SOLUTIONS

N4S 8V8WOODSTOCK, ONTARIO

UNIT #165 SPRINGBANK AVE. N.

18134GMImainM4

STAMP NORTH ARROW

DATE

ISSUED FORPRELIMINARYCLIENT REVIEWSITE PLAN APPROVAL

BUILDING PERMITTENDERCONSTRUCTION

2018-10-01

.

Toll Free: 1-877-392-9766

Tel: (519) 842-4392

49 North Street East , Tillsonburg , ON N4G 1B4

email:[email protected]

Fax: (519) 688-2470

CONSTRUCTION LTD.

Grassmere

ww

w.g

rass

me

re.c

om

design-build construction services

R. W. SPENCER

RE

G

IS

T

E

R

E

D

P

R

O

F

ESS

IO

N

A

L

E

N

G

IN

EE

R

P

R

O

V

I

N

C

E

OF

O

N

T

A

R

I

O

100191633

2018-10-01

2018-04-12

GG RS

AS NOTED

18134

TRAILER/MAINTENANCE AREA

POWER LAYOUTS

PROPOSED ADDITIONSGMI BUILDING

BEARDS LANE, WOODSTOCK, ON

E3

N

NEW ELECTRICAL LAYOUT

SCALE: N.T.S.

MAINTENANCE SHOP POWER LAYOUT

SCALE:

1

4

"=1'-0"

DRIVE THROUGH SHELTER POWER LAYOUT

SCALE:

1

16

"=1'-0"

AutoCAD SHX Text
UPDATED NOTE ON
AutoCAD SHX Text
ELECTRICAL LAYOUT
AutoCAD SHX Text
1
AutoCAD SHX Text
ADD TAG FOR HEAT TRACE
AutoCAD SHX Text
2018-10-01
Page 10: PROFESIO D - grassmere.comgrassmere.com/wp-content/uploads/2018/10/M-E-Drawings-revised-… · profesio n a l e n g i n e e r p r o v in ceofon ta rio 100191633 2018-10-01 2018-04-12

SAND

GRADE LEVEL

75m

m75m

m

900m

m

190mm

WARNING TAPE

450m

m

190mm 190mm 190mm 190mm

A BC C

B A N

190mm

N

190mm

1

SAND

CABLE

FINISHED FLOOR

75m

m75m

m

900m

m

300m

m

CONDUIT WITH

BELL END

TP1

120/208 PANEL

PROPOSED

ADDITION

F.F.E. = 299.25

PROPOSED

ADDITION

F.F.E. = 299.25

EXISTING GMI BUILDING

F.F.E. = 299.25

EXISTING GMI OFFICE

PROPOSED

ADDITION

F.F.E. = 299.25

(MATCH EXISTING)

PROPOSED

DRIVE THROUGH

SHELTER

LOADING

DOCK

TRENCH TO SHELTER

SEE NOTE 6

SEE NOTE 5

ENTRANCE SWITCH

TRENCH TO NEW ELECTRICAL ROOM.

SEE DETAIL 1.

NEW 750 KVA TRANSFORMER

EXISTING SERVICE TO OFFICE BUILDING.

DISCONNECT FROM EXISTING TRANSFORMER

AND CONNECT TO NEW TRANSFORMER.

PANEL C

LAMP POST

CARD READER

RELOCATE EXISTING

LIGHT AND CARD READER

NOTES:

1. UNLESS OTHERWISE NOTED, DIRECTLY BURIED CABLES SHALL BE INSTALLED TO MEET MINIMUM

COVER REQUIREMENTS OF 900mm FROM THE TOP OF THE CABLE TO THE FINISHED GRADE.

2. BACKFILL CONTAINING LARGE ROCK, PAVING MATERIAL, CINDERS, LARGE OR SHARPLY ANGULAR

SUBSTANCES, OR CORROSIVE MATERIAL SHALL NOT BE USED IN THE CABLE TRENCH.

3. SUITABLE MARKING TAPE SHALL BE BURIED DIRECTLY ABOVE THE CABLE(S) AND AT AN

APPROXIMATE DEPTH HALFWAY BETWEEN THE SABLE(S) AND THE FINISHED GRADE.

4. CABLES ENTERING THROUGH THE FINISHED FLOOR REQUIRE A BELL END CONDUIT TERMINATING

300mm ABOVE THE TRENCH FLOOR. SEE DETAIL 2.

5. RUN CABLE FROM PANEL TO ROOF. CONTRACTOR IS TO DETERMINE BEST ROUTING FOR CABLE

ALONG THE ROOF TO THE CORNER OF THE ADDITION AND BACK DOWN TO TRENCH.

6. DIRECT BURY CABLE IN TRENCH AS PER DETAIL 3.

NOTES:

1. RELOCATE LAMP POST AND CARD READER TO LOCATION SHOWN.

2. EXTEND TRENCH AND WIRING TO NEW LOCATIONS.

3. SEE DRAWING P5 FOR CONCRETE WORK.

SAND

GRADE LEVEL

900m

m

WARNING TAPE

450m

m

PROJECT NUMBER

DRAWN CHECKED

SCALEDATE

FILE NAME

DRAWING

DATEDESCRIPTIONREV.

This drawing is the property ofSPH Engineering Inc. and is not tobe copied or distributed for anyreason or by any means withoutthe permission of the owner.

DRAWING

PROJECT

CLIENT

FAX: 519-539-5775TEL: 519-539-5700

SPH ENGINEERING INC.REAL WORLD ENGINEERING SOLUTIONS

N4S 8V8WOODSTOCK, ONTARIO

UNIT #165 SPRINGBANK AVE. N.

18134GMImainM4

STAMP NORTH ARROW

DATE

ISSUED FORPRELIMINARYCLIENT REVIEWSITE PLAN APPROVAL

BUILDING PERMITTENDERCONSTRUCTION

2018-10-01

.

Toll Free: 1-877-392-9766

Tel: (519) 842-4392

49 North Street East , Tillsonburg , ON N4G 1B4

email:[email protected]

Fax: (519) 688-2470

CONSTRUCTION LTD.

Grassmere

ww

w.g

rass

me

re.c

om

design-build construction services

R. W. SPENCER

RE

G

IS

T

E

R

E

D

P

R

O

F

ESS

IO

N

A

L

E

N

G

IN

EE

R

P

R

O

V

I

N

C

E

OF

O

N

T

A

R

I

O

100191633

2018-10-01

2018-04-12

GG RS

AS NOTED

18134

SITE LAYOUT ANDTRENCHING DETAILS

PROPOSED ADDITIONSGMI BUILDING

BEARDS LANE, WOODSTOCK, ON

E4

N

DETAIL 1 (2 WIRES PER PHASE)

DETAIL 2 (CABLE ENTERING THROUGH FINISHED FLOOR)

SITE ELECTRICAL PLAN

SCALE: N.T.S.

DETAIL 3

AutoCAD SHX Text
1
AutoCAD SHX Text
UPDATED DETAIL 1
AutoCAD SHX Text
2018-10-01
Page 11: PROFESIO D - grassmere.comgrassmere.com/wp-content/uploads/2018/10/M-E-Drawings-revised-… · profesio n a l e n g i n e e r p r o v in ceofon ta rio 100191633 2018-10-01 2018-04-12

ELECTRICAL LIGHTING SCHEDULE

INDEX MANUFACTURER

LUMINAIRE

TYPE

ITEM NUMBER

STELLA UNIBODY RUNNING

MAN COMBO EXIT AND

SAFETY LIGHT

BEGHELLI CANADA

SLU-RM-6-80-L-1-

OLR-C-BTMR2-5W

-

LUMINOUS

FLUX

120V

VOLTAGE

5

QUANTITY

1

CONNECTED

LOAD

2 W

FBX HIGHBAY 8-2LINEP

2.62L5 4000K BOARDS

4-95W DRIVERS 5.1K

RESISTORS NO OPTICS OPEN

PHILIPS FBX36LL40-347 37102 lm 347V 202 255.5 W

INSTALLATION

WALL MOUNT

ABOVE DOOR

SUSPENDED

39' AFF

PHILIPS 4' VAPORLUME

2-LP3.2.1 4000K BOARDS

95W DRIVER 1.37K

RESISTOR

PHILIPS

DWAE51LH840-4-

UNV

5186 lm 208V 213 47.4 W

SHELTER TENT -

SURFACE MOUNT

ON PURLINS

VALVE ROOM -

SURFACE MOUNT

4' LBX 2-2LP 1.0 4000K

BOARDS 75W DRIVER 9.1K

RESISTOR

PHILIPS LBX70L840-347 7904 lm 347V 84 53.4 W

SUSPENDED

12' AFF

GARDCO FLOODLIGHT

PHILIPS

FX2-128-G2-T-A-

RM-N-A-3-N-N

16204 lm 120V 3

5

139 W

WALL MOUNT

12' AFF

ECCO LUNA LED EMERGENCY

LIGHT

BEGHELLI CANADA

CO1A-10W-205L-

EO-120/277/347

- 120V 6

6

-

WALL MOUNT

12' AFF

FLOOD LIGHT WITH PHOTO

CELL

ECO POWER

FLF-G2-80W-CW-

V4-B002

8590 lm 208V 12

7

78.9 W

SURFACE MOUNT

22' AFF

FBX HIGHBAY 8-2LINEP

2.62L5 4000K BOARDS

4-95W DRIVERS 5.1K

RESISTORS NO OPTICS OPEN

PHILIPS FBX36LL40-347 37102 lm 347V 48 255.5 W

SUSPENDED

45' AFF

1

ELECTRICAL LEGEND

120V RECEPTACLE

COMBINATION EXIT SIGN/EMERGENCY LIGHTING UNIT

EXTERIOR LIGHT FIXTURE

ELECTRIC MOTORS OR MOTORIZED EQUIPMENT

2' x 4' CEILING LIGHT FIXTURE

X

6" x 4' CEILING LIGHT FIXTURE

WELD OUTLET

ELECTRIC DISCONNECT

EMERGENCY LIGHTING UNIT

PANEL - CIRCUIT NUMBERPC-#

MOTORIZED DAMPERMD

750KVA

PAD-MOUNTED TRANSFORMER

ISC = 15.5 KA

600A, 600V

SERVICE ENTERING SWITCH

NEW METERING CABINET AS PER

HYDRO ONE SPECIFICATIONS

100A, 600V

DISCONNECT

300A, 600V

DISCONNECT

SCRAP BALER

347/600V PANEL

3PH 4 WIRE

100A MAIN DISCONNECT

45KVA

347/600V PRIMARY

120/208 SECONDARY

3 PHASE 4 WIRE

SUB 2

120/208V

3 PHASE 4 WIRE PANEL

100A MAIN DISCONNECT

A

B

E

E

C

D

D

F

G

B

A) 2x PARALLEL RUNS OF 600 MCM AI RWU90 (SEE DETAIL 1 PAGE E4)

B) 2x PARALLEL RUNS OF 400 MCM CU R90 78mm CONDUIT

C) 2x PARALLEL RUNS OF 4/0 AWG CU 63mm CONDUIT

D) 2 AWG CU R90 41mm CONDUIT

E) 400 MCM CU R90 78mm CONDUIT

F) 8 AWG CU R90 27mm CONDUIT

G) 1 AWG CU R90 41mm CONDUIT

600A 347/600V SPLITTER

400A, 600V

DISCONNECT

C

TO EXISTING SPLITTER

IN EXISTING BUILDING

60A, 600V

DISCONNECT

SUB 1

347-600V

3 PHASE 4 WIRE

100A MAIN DISCONNECT

GROUND INCOMING SERVICE AS

PER OESC 10-204.

PROVIDE GROUND ELECTRODES

AS PER OESC 10-700 AND #3/0

CU GROUND CONDUCTORS TO

GROUND INCOMING SERVICE.

DO NOT RELY ON THE WATER

MAIN FOR A GROUND.

1

1

2

4

1

3

PANEL SCHEDULE

EXTERIOR LIGHTS

15 A

PANEL NAME: TP1

VOLTAGE: 120/208V

MAINS AMP: 100 A

A B C

RECEPTACLES

15 A

65

8

10

7

9

1211

14

16

13

15

1817

NOTES:

1. PANEL REQUIRES INGRESS

PROTECTION IP44.

2. CONTRACTOR TO FEED PANEL TP1

FOR AVAILABLE CIRCUIT IN PANEL C.

15 A

15 A

EMERGENCY LIGHTS

BAY LIGHTS

2

4

1

3

PANEL SCHEDULE

BAND SAW

20 A

PANEL NAME: PP2

VOLTAGE: 120/208V

MAINS AMP: 125 A

A B C

HVAC

25 A

20 A

BENCH RECEPTACLES

15 A

65

20 A

8

10

7

9

1211

14

16

13

15

1817

20

22

19

21

2423

26

28

25

27

3029

32

34

31

33

3635

38

40

37

39

4241

TABLE SAW

DRILL PRESS

FUTURE TOOL

20 A

20 A

WELD RECP.

50 A

SUB PANEL

FUTURE TOOL

20 A

EMERGENCY LIGHTS

15 A

FURNACE

15 A

INTAKE LOUVER

15 A

WATER HEATER

20 A

EXTERIOR LIGHTS

15 A

20 A

HEAT TRACE

SUMP PUMP

15 A

HEAT RECOVERY UNIT

15 A

EXHAUST FAN 3

15 A

EXHAUST FAN 4

15 A

2

4

1

3

PANEL SCHEDULE

50 A

PANEL NAME: PP1

VOLTAGE: 347/600V

MAINS AMP: 100 A

A B C

30 A

AIR COMPRESSOR

65

8

10

7

9

1211

14

16

13

15

1817

SUB PANEL

15 A

LIGHTS

1

2

4

1

3

PANEL SCHEDULE

PANEL NAME: SUB 1

VOLTAGE: 347/600V

MAINS AMP: 100 A

A B C

DOOR OPERATOR

65

8

10

7

9

1211

14

16

13

15

1817

20

22

19

21

2423

DOOR OPERATOR

LIGHT BANK 1

LIGHT BANK 2 DOOR OPERATOR

15 A

15 A

2

4

1

3

PANEL SCHEDULE

RECEPTACLES

15 A

PANEL NAME: SUB 2

VOLTAGE: 120/208V

MAINS AMP: 100 A

A B C

SUMP PUMP

15 A

20 A

MAINTENANCE FLOODS

15 A

65

8

10

7

9

1211

14

16

13

15

1817

20

22

19

21

2423

MAINTENANCE RECP.

EXIT AND EMERG. LIGHTS

15 A20 A

EXHAUST FANS DAMPER MOTORS

15 A

BASE BOARD HEATER

15 A

GAS DETECTORS

15 A15 A

VALVE ROOM LIGHT

20 A

WELD RECP.

EXISTING PANEL C

30A BREAKER

CONTRACTOR TO DETERMINE

AVAILABLE CIRCUIT

PANEL TP1

10 AWG CU 21mm

CONDUIT UNTIL TRENCH

THEN DIRECT BURY

X MD

MOTORIZED

DAMPER

X

EF

EF

EF1

EF2

CONTACTOR

120V, 15A

CONTACTOR

208V, 20A

CONTROL

PANEL

GAS MONITORING

SYSTEM

NOTES:

1. A CONTROL PANEL IS TO BE SUPPLIED. THIS PANEL SHALL ALLOW

FOR MANUAL OPERATION OF EF-1 AND EF-2 INDEPENDENTLY.

2. ACTUATION OF ANY OR ALL OF THE EXHAUST FANS SHALL OPEN

THE INTAKE LOUVERS.

3. OPERATING LIGHTS SHALL INDICATE IF FANS ARE OPERATIONAL.

4. ALARM FROM GAS MONITORING SYSTEM SHALL OVERRIDE ANY

MANUAL SETTINGS AND ACTUATE BOTH FANS.

120V

C

N

BANK 1 BANK 2 N

2 POLE LIGHTING CONTACTOR IN

GENERAL PURPOSE ENCLOSURE

30A, 347V c/w 120V COIL.

ALLEN BRADLEY OR EQUIVALENT.

TAG

HT.1

MODEL

ELECTRICAL EQUIPMENT SCHEDULE

MOCP (AMPS)

DESCRIPTION MAKE VOLTAGE

POWER AND THERMOSTAT CONTROLLER CHROMALOX UBC

208/1/60

20

NOTE: HT.1 WILL POWER CHROMOLOX SRF 5-2C CABLE. TO BE INSTALLED AS PER MANUFACTURERS INSTRUCTIONS.

1

HVAC EQUIPMENT SCHEDULE

TAG ID DESCRIPTION MAKE MODEL

AIR FLOW

(CFM)

HEATING

INPUT

COOLING

CAPACITY

VOLTAGE

UNIT WEIGHT

kg (lbs)

REMARKS

F.1 NEW FURNACE GOODMAN GMS800603AN 1200 60 MBH

115/1/60

HEATING

OUTPUT

-48 MBH

40 (88)

INSTALL AS PER MANUFACTURER'S INSTRUCTIONS.

MCA (AMPS) MOCP (AMPS)

154.8

HRV.1 HEAT RECOVERY VENTILATOR LIFEBREATH 195 DCS 216 -

120/1/60

--

40 (88)

INSTALL AS PER MANUFACTURER'S INSTRUCTIONS.151.5

AC.1 AIR CONDITIONER GOODMAN GSX130301 - -

208/1/60

27 MBH-

52.3 (115)

INSTALL AS PER MANUFACTURER'S INSTRUCTIONS.2516.7

CC.1 COOLING COIL GOODMAN CHPF2430B6 - - -27 MBH-

25 (55)

INSTALL AS PER MANUFACTURER'S INSTRUCTIONS.--

NOTE: EQUIPMENT OF EQUAL PERFORMANCE IS ACCEPTABLE

EBB.1 ELECTRIC BASEBOARD HEATER OUELLET OPR1002 - -

120/1/60

-1000 W

11.8 (26)

INSTALL AS PER MANUFACTURER'S INSTRUCTIONS.15-

HEIGHTUNIT#

HWT.1

CAPACITY

WATER HEATER SCHEDULE

INPUT (kW)

MAKE MODEL # DIAMETER SHIPPING WEIGHTTYPE

A.O.SMITH EJC-6 6 USG ELECTRIC 1650 15.25" 14.25" 35 lbs

WEIGHT W/ WATER

~85 lbs

NOTE: EQUIPMENT OF EQUAL PERFORMANCE IS ACCEPTABLE

EXHAUST FAN SCHEDULE

EF-1,2

WALL MOUNTED EXHAUST FAN

FAN # DESCRIPTION MAKE MODEL

AIR FLOW

(CFM)

STATIC

PRESSURE

FAN MOTOR

kW (HP)

VOLTAGE

UNIT WEIGHT

kg (lbs)

GREENHECK AER-E36C-310-A 18000

2.87 (3.85)

0.4 in wc

208/60/3 72.7 (160)

FLA

16.7

EF-3 ROOF MOUNTED EXHAUST FAN GREENHECK GB-161 1800

0.142 (0.19)

0.2 in wc

120/1/6028.6 (63)

5.8

EF-4 ROOF MOUNTED EXHAUST FAN GREENHECK G-090-E 300

0.015 (0.02)

0.2 in wc

120/1/60 11.8 (26)

-

NOTE: EQUIPMENT OF EQUAL PERFORMANCE IS ACCEPTABLE

PUMP SCHEDULE - ELECTRICAL

TAG # DESCRIPTION MAKE MODEL # MOTOR

SUBMERSIBLE WASTE

WATER SUMP PUMP

SP-1

HEAD

Meters (Feet)

FLOW

L/s (gpm)

ZOELLER 49

1/4hp (0.19 kW) 3 (10) 1.6 (25)

MCA (AMPS) MOCP (AMPS)VOLTAGE

120/1/60

4.0 15

REMARKS

INSTALL PER MANUFACTURERS INSTALLATION

INSTRUCTIONS

PREASSEMBLED WASTE

WATER SUMP PUMP SYSTEM

SP-2 ZOELLER 900-0002

3/10hp (0.22 kW) 3 (10) 2.2 (35)120/1/60

9.7 15

INSTALL PER MANUFACTURERS INSTALLATION

INSTRUCTIONS

NOTE: EQUIPMENT OF EQUAL PERFORMANCE IS ACCEPTABLE

LOUVERS & DAMPERS SCHEDULE

MOTORIZED DAMPER

TAG ID DESCRIPTION SIZE MAKE REMARKS

TAMCO

MODEL

SERIES 1000

BELIMO DAMPER MOTOR & ALL CONTROLS

MOTOR ELECTRICAL: 120/1/60, END SWITCHES

TO SUIT LOUVER

& EXHAUST FAN

MD-1, 2, 3

NOTE: EQUIPMENT OF EQUAL PERFORMANCE IS ACCEPTABLE

PROJECT NUMBER

DRAWN CHECKED

SCALEDATE

FILE NAME

DRAWING

DATEDESCRIPTIONREV.

This drawing is the property ofSPH Engineering Inc. and is not tobe copied or distributed for anyreason or by any means withoutthe permission of the owner.

DRAWING

PROJECT

CLIENT

FAX: 519-539-5775TEL: 519-539-5700

SPH ENGINEERING INC.REAL WORLD ENGINEERING SOLUTIONS

N4S 8V8WOODSTOCK, ONTARIO

UNIT #165 SPRINGBANK AVE. N.

18134GMImainM4

STAMP NORTH ARROW

DATE

ISSUED FORPRELIMINARYCLIENT REVIEWSITE PLAN APPROVAL

BUILDING PERMITTENDERCONSTRUCTION

2018-10-01

.

Toll Free: 1-877-392-9766

Tel: (519) 842-4392

49 North Street East , Tillsonburg , ON N4G 1B4

email:[email protected]

Fax: (519) 688-2470

CONSTRUCTION LTD.

Grassmere

ww

w.g

rass

me

re.c

om

design-build construction services

R. W. SPENCER

RE

G

IS

T

E

R

E

D

P

R

O

F

ESS

IO

N

A

L

E

N

G

IN

EE

R

P

R

O

V

I

N

C

E

OF

O

N

T

A

R

I

O

100191633

2018-10-01

2018-04-12

GG RS

AS NOTED

18134

ELECTRICAL LEGENDS,SCHEDULES AND

DETAILS

PROPOSED ADDITIONSGMI BUILDING

BEARDS LANE, WOODSTOCK, ON

E5

N

ELECTRICAL POWER LAYOUT AND WIRE DETAILS

DRIVE THROUGH SHELTER

SINGLE LINE DIAGRAM

VENTILATION CONTROLS

INTERIOR LIGHTING CONTROL DIAGRAM

AutoCAD SHX Text
S
AutoCAD SHX Text
UPDATED PANEL SCHEDULES
AutoCAD SHX Text
FOR LIGHTING CIRCUITS
AutoCAD SHX Text
UPDATED QUANTITY IN LIGHT
AutoCAD SHX Text
SCHEDULE
AutoCAD SHX Text
ADDED GROUNDING NOTES
AutoCAD SHX Text
UPDATED TAG FOR HEAT TRACE
AutoCAD SHX Text
1
AutoCAD SHX Text
UPDATED NOTE ON POWER
AutoCAD SHX Text
LAYOUT AND WIRE DETAILS
AutoCAD SHX Text
2018-10-01
Page 12: PROFESIO D - grassmere.comgrassmere.com/wp-content/uploads/2018/10/M-E-Drawings-revised-… · profesio n a l e n g i n e e r p r o v in ceofon ta rio 100191633 2018-10-01 2018-04-12

PART 1 : GENERAL REQUIREMENTS

1. REQUIREMENTS INCLUDED

1. THE GENERAL REQUIREMENTS, DIVISION 01 AND ANY SUPPLEMENTARY GENERAL CONDITIONS

OF THE CONTRACT SHALL FORM A PART OF THIS SPECIFIFICATION. THE REQUIREMENTS OF

THIS SECTION APPLY TO ALL SECTIONS OF THIS SPECIFICATION.

2. THE DRAWINGS AND SPECIFICATIONS COMPLIMENT EACH OTHER AND TOGETHER STIPULATE

THE CONTRACT REQUIREMENTS. THE MORE RESTRICTIVE CONDITIONS APPLY WHEN

INTERPRETING DISCREPANCIES BETWEEN THE DRAWINGS AND SPECIFICATIONS.

3. FULLY UNDERSTAND THE INTENT AND FUNCTION OF THE SYSTEMS DESCRIBED IN THIS

SPECIFICATION. ALL ELECTRICAL SYSTEMS COVERED UNDER DIVISION 16 SHALL BE FULLY

COMPLETE, TESTED, OPERABLE AND READY FOR OWNER'S USE. USE THE INFORMATION

CONTAINED IN THE RELEVANT DRAWINGS AND/OR SPECIFICATION SECTIONS SUPPLEMENTED

WITH DATE CONTAINED WITHIN OTHER SPECIFICATION SECTIONS OR PROVIDED BY

EQUIPMENT SUPPLIERS OR OTHER SUB-CONTRACTORS. NO EXTRA WILL BE ALLOWED IN ORDER

TO COMPLETE SYSTEMS INADEQUATELY INSTALLED OR NOT FULLY OPERATIONAL.

2. WORK INCLUDED1. PROVIDE ALL LABOUR, MATERIAL, EQUIPMENT, TOOLS AND TRANSPORTATION FOR THE SUPPLY

AND INSTALLATION OF COMPLETE ELECTRICAL SYSTEMS AS SHOWN ON THE DRAWINGS,

SPECIFIED HEREIN OR AS REASONABLY INFERABLE FROM EITHER.

3.REFERENCES1. PROVIDE MATERIAL CONFORMING TO THE MOST UP-TO-DATE CSA AND/OR ULC REQUIREMENTS.

2. REGULATORY AGENCIES:

1. ELECTRICAL SAFETY AUTHORITY

4. WORKMANSHIP1. ONLY FIRST-CLASS WORKMANSHIP PERFORMED BY QUALIFIED TRADE-PERSONS WILL BE

ACCEPTED. NOT ONLY WITH REGARDS TO SAFETY AND DURABILITY BUT ALSO IN TERMS OF

ACCESSIBILITY AND NEATNESS OF DETAIL. UNSATISFACTORY WORKMANSHIP SHALL BE

CORRECTED AT THE CONTRACTOR'S EXPENSE.

2. EMPLOY SPECIALIZED LABOUR AS REQUIRED FOR THE INSTALLATION, TESTING AND/OR

COMMISSIONING OF SPECIFIC SYSTEMS TO ENSURE PROPER OPERATION.

3. THE CONTRACTOR IS RESPONSIBLE FOR ALL DAMAGES RESULTING FROM THE EXECUTION OF

THIS WORK.

5.DRAWINGS1. THE DRAWINGS ARE INTENDED TO BE DIAGRAMMATIC AND INDICATE THE GENERAL

ARRANGEMENT OF EQUIPMENT ONLY. NOT ALL BUILDING ELEMENTS ARE SHOWN. DO NOT

SCALE THE DRAWINGS OR USE FOR FABRICATION PURPOSES.

2. MAKE USE OF ALL AVAILABLE DOCUMENTATION, PRIOR TO TENDER, IN ORDER TO DETERMINE

THE SCOPE OF WORK. NO CONCESSION SHALL BE MADE FOR FAILURE TO MAKE USE OF THE

COMPLETE PACKAGE OF DRAWINGS AND SPECIFICATIONS MADE AVAILABLE DURING THE

TENDER PERIOD.

3. MAKE ALLOWANCES FOR SITE CONDITIONS AND CO-ORDINATION WITH OTHER TRADES.

6.RECORD DRAWINGS1. ONE SET OF PRINTS SHALL BE MAINTAINED IN GOOD CONDITION ON THE JOB-SITE AND BE

MARKED WITH RED INK TO INDICATE DEVIATIONS MADE FROM THE ORIGINAL, TENDERED

DRAWINGS. THESE DRAWINGS SHALL BE LABELLED “AS BUILT” AND SUBMITTED TO THE

ENGINEER PRIOR TO FINAL INSPECTION.

7. SHOP DRAWINGS1. SUBMIT SHOP DRAWINGS FOR EQUIPMENT AS INDICATED IN THE INDIVIDUAL SPECIFICATION

SECTIONS. DO NOT ORDER EQUIPMENT PRIOR TO RECEIPT OF APPROVED SHOP DRAWINGS.

2. SHOP DRAWINGS SHALL CONTAIN THE FOLLOWING INFORMATION:

1. EQUIPMENT DESIGNATION FROM DRAWINGS (E.G. POWER PANEL 'A', LIGHT FIXTURE 'BB').

2. GENERAL CONTRACTOR AND ELECTRICAL SUBCONTRACTOR'S REVIEW STAMP.

3. MANUFACTURER AND CATALOGUE OR MODEL NUMBER.

4. EQUIPMENT RATINGS, DIMENSIONS AND WEIGHT.

5. THE ENGINEER'S REVIEW OF SHOP DRAWINGS IS TO ENSURE GENERAL CONFORMITY WITH THE

INTERNET OF THE DESIGN. THE ELECTRICAL SUB-CONTRACTOR BEARS FULL RESPONSIBILITY

FOR ACTUAL EQUIPMENT DESIGN, QUALITY, FUNCTION, CODE COMPLIANCE AND INSTALLATION.

8.PERMITS AND FEES1. OBTAIN AND PAY FOR ALL PERMITS REQUIRED FOR THE EXECUTION OF THE WORK GOVERNED

BY THIS SPECIFICATION.

2. CHARGES OR FEES TO LOCAL UTILITIES IN CONJUNCTION WITH THEIR WORK ASSOCIATED

WITH THE PROJECT WILL BE PAID DIRECTLY BY THE OWNER. PROVIDE TO THE UTILITIES ANY

INFORMATION THEY REQUIRE IN ORDER TO DETERMINE THEIR SCOPE OF WORK.

3. UPON COMPLETION OF THE WORK PROVIDE AN UNCONDITIONAL CERTIFICATE OF ACCEPTANCE

FROM ONTARIO ELECTRICAL SAFETY AUTHORITY.

9.RULES AND REGULATIONS1. ENSURE THAT THE INSTALLATION CONFORMS TO ALL REQUIREMENTS OF THE MOST CURRENT

ONTARIO ELECTRICAL SAFETY CODE AND BULLETINS, ONTARIO BUILDING CODE, CSA

STANDARDS, ONTARIO FIRE CODE AND/OR ANY OTHER APPLICABLE MUNICIPAL OR PROVINCIAL

REGULATION.

2. THE DRAWINGS SHOW THE MINIMUM STANDARD ACCEPTABLE REGARDLESS OF ANY LESSER

STANDARD SET BY APPLICABLE CODE OR REGULATION.

10. INSPECTION1. THE WORK SHALL BE AVAILABLE FOR INSPECTION BY THE ENGINEER AT ANY TIME.

2. IF WORK IS DETERMINED TO BE UNACCEPTABLE IN TERMS OF THESE SPECIFICATIONS, THE

CONTRACTOR SHALL TAKE IMMEDIATE MEASURES TO CORRECT THE DEFICIENCY.

3. INFORM THE ENGINEER WHEN THE WORK IS READY FOR FINAL INSPECTION. DEFECTS SHALL BE

MADE GOOD BEFORE FINAL PAYMENT IS AUTHORIZED.

11. ABBREVIATIONS AND DEFINITIONS1. WHEREVER WORDS SUCH

AS “APPROVED”, “SATISFACTORY”, “DIRECTED”, “PERMITTED”, “REQUIRED” OR SIMILAR

PHRASES ARE USED IN THIS SPECIFICATION IT SHALL BE IMPLIED THAT THE

WORDS “BY (TO) THE ENGINEER” FOLLOWS.

2. WHEREVER THE WORD “PROVIDE” IS USED IT SHALL BE UNDERSTOOD THAT IT IS EQUIVALENT

TO “FURNISH AND INSTALL”, COMPLETE AND IN PLACE, INCLUDING

ACCESSORIES, FINISHES, TESTS AND SERVICES TO RENDER ITEM SO SPECIFIED COMPLETE

READY FOR USE.

3. WHEREVER THE WORD “FURNISH” IS USED IT MEANS PROCUREMENT OF FABRICATION OF

MATERIALS, EQUIPMENT, OR COMPONENTS, OR PERFORMANCE OF SERVICES TO EXTENT

SPECIFIED AND SHOWN. WHERE USED WITH RESPECT TO MATERIALS, EQUIPMENT, OR

COMPONENTS, THE TERM INCLUDES CRATING AND DELIVERY TO PROJECT SITE BUT IS NOT

INTENDED TO INCLUDE INSTALLATION OF ITEM, EITHER TEMPORARY OR FINAL.

4. WHEREVER THE WORD “INSTALL” IS USED IT MEANS PLACEMENT OF MATERIALS, OR

COMPONENTS, INCLUDING RECEIVING, UNLOADING, TRANSPORTING, STORAGE, UNCRATING

AND INSTALLING AND PERFORMANCE OF SUCH TESTING AND FINISH WORK AS IS COMPATIBLE

WITH THE DEGREE OF INSTALLATION SPECIFIED.

1. ABBREVIATIONS COMMONLY USED ON THE DRAWINGS ARE LISTED BELOW:

1/2/3P SINGLE, DOUBLE OR THREE POLE

A AMPS/AMPERAGE

B/F BARRIER FREE

C CONDUIT

CSA CANADIAN STANDARDS ASSOCIATION

DP DISTRIBUTION PANEL

ESA ELECTRICAL SAFETY AUTHORITY

FHP FRACTIONAL HOSE POWER

MH MOUNTING HEIGHT

NBC NATIONAL BUILDING CODE

OBC ONTARIO BUILDING CODE

OESC ONTARIO ELECTRICAL SAFETY CODE

SN SOLID NEUTRAL

SWBRD SWITCHBOARD

ULC UNDERWRITER'S LABORITORIES OF CANADA

W WATTS/WATTAGE

WP WEATHERPROOF

WM WALL MOUNTED

V VOLTS/VOLTAGE

XFRMR TRANSFORMER

PART 2: PRODUCTS1. MATERIALS AND EQUIPMENT1. MATERIALS TO BE NEW AND CSA/ULC APPROVED.

2. MATERIALS AND EQUIPMENT SPECIFIED BY TECHNICAL DESCRIPTION ONLY SHALL BE

OF THE BEST QUALITY ATTAINABLE FOR APPLICATION.

3. USE THE SAME MANUFACTURER, TYPE AND STYLE OF EQUIPMENT FOR PARTICULAR

GROUPINGS, CLASS OR TYPE OF EQUIPMENT USED ON THE PROJECT.

4. REQUESTS FOR CHANGES TO THE PROJECT SCHEDULE, EQUIPMENT OR CONTRACT

VALUE DUE TO LATE ORDERING OF EQUIPMENT WILL NOT BE CONSIDERED.

2. SUBSTITUTIONS1. REQUESTS FOR APPROVAL OF ALTERNATIVE EQUIPMENT SHALL BE SUBMITTED

COMPLETE WITH ALL PHYSICAL AND PERFORMANCE SPECIFICATIONS AND SHALL NOT

DELAY THE PROJECT SCHEDULE. ALTERNATE EQUIPMENT INSTALLED WITHOUT

WRITTEN APPROVAL MAY BE REPLACED, AT NO COST TO THE OWNER, WITH THE

SPECIFIED EQUIPMENT.

2. MAKE ALLOWANCE FOR THE WORK OF THE GENERAL CONTRACTOR OTHER

SUB-CONTRACTORS AFFECTED BY THE USE OF THE ALTERNATE EQUIPMENT.

QUOTATIONS SUBMITTED WITH RESPECT TO THE USE OF THE SUBSTITUTE SHALL

INCLUDE THE COSTS INCURRED BY ANY OTHER TRADES AFFECTED BY THE USE OF THE

PROPOSED EQUIPMENT.

3. CONDUCTORS1. MINIMUM GAUGE FOR CONDUCTORS USED FOR POWER CIRCUITS IS #12 AWG COPPER.

THE SIZE TO BE ADJUSTED FOR DE-RATING DUE TO CONDUIT FILL, AMBIENT

TEMPERATURE AND TO LIMIT VOLTAGE DROP TO NO MORE THAN 2% ON ANY FEEDER

OR BRANCH CIRCUIT.

2. INSULATION TO BE RATED AT 600 VOLT EQUAL TO CSA RATED T90 (NYLON) OR

R/RW/RWU90 (CROSS-LINKED POLYETHYLENE) AND WHERE A SPECIFIC TYPE OF

INSULATION IS SHOWN THAT TYPE SHALL BE USED.

3. ALL CONDUCTORS SHALL BE COLOUR CODED AT TERMINATIONS TO PANEL(S) AND

EQUIPMENT. FOR CONDUCTORS #10 AWG AND SMALLER THE COLOUR SHALL BE THE

INSULATION OF THE CONDUCTOR. LARGER CONDUCTORS MAY BE PROVIDED WITH

A 2” (50MM) BAND OF APPROPRIATELY COLOURED TAPE ADJACENT TO THE

TERMINATION.

4. INSULATION COLOUR CODING TO BE AS FOLLOWS:

PHASE “A” RED

PHASE “B” BLACK

PHASE “C” BLUE

NEUTRAL WHITE

GROUND GREEN

4. RACEWAYS1. PROVIDE RACEWAYS AS INDICATED ON THE DRAWINGS. WHERE SIZE IS NOT SPECIFIED

PROVIDE IN ACCORDANCE WITH THE REQUIREMENTS ON THE OESC.

2. THE FOLLOWING CONDUIT TYPES ARE APPROVED FOR USE ON THIS PROJECT:

1. ELECTRICAL METALLIC TUBING (EMT) FOR GENERAL USE.

2. RIGID ALUMINUM CONDUIT (RAC) WHERE SUSCEPTIBLE TO MECHANICAL DAMAGE.

3. RIGID POLYVINYL CHLORIDE (PVC) CONDUIT BELOW GRADE OR IN POURED CONCRETE

STRUCTURES.

4. LIQUID TIGHT FLEXIBLE METALLIC CONDUIT FOR FINAL CONNECTIONS TO EQUIPMENT.

5. UTILIZE STEEL, SETCREW CONNECTIONS AND COUPLINGS FOR EMT CONDUIT. DIE-CAST

OR PRESSURE-CAST CONNECTORS AND COUPLINGS ARE NOT ACCEPTABLE. LIQUID

TIGHT FITTINGS ARE TO BE USED OUTDOORS OR WHERE CONDUIT IS DIRECTLY

EXPOSED TO MOISTURE.

5. ARMORED CABLES1. WHERE PERMITTED, MULTIPLE CONDUCTOR, ARMORED CABLES MAY BE AC-90,

ACWU-90 OR TECK-90 WITH COPPER CONDUCTORS.

2. WHERE PERMITTED, SINGLE CONDUCTOR, ARMORED CABLES MAY BE ACWU-90 OR

RA-90 WITH COPPER CONDUCTORS.

6. STANDARD OUTLET BOXES1. SIZE AND SELECT INDIVIDUAL BOXES IN ACCORDANCE WITH THE OESC BASED ON THE

INSTALLED DEVICE(S) AND THE NUMBER AND GAUGE OF CONDUCTORS CONTAINED

WITHIN AND FOR THE INSTALLED LOCATION.

2. WHEREVER MULTIPLE DEVICES ARE SHOWN IN A GROUP PROVIDE GANGED BOXES

COMPLETE WITH A SUITABLE PLASTER-RING AND INTERNAL BARRIERS WHERE OUTLETS

FOR MORE THAN ONE SYSTEM ARE GROUPED.

3. CAST ALUMINUM BOXES SHALL BE USED IN SURFACE MOUNT OUTDOOR APPLICATIONS.

4. PVC BOXES SHALL BE USED IN CONCRETE STRUCTURES.

5. OUTLET BOXES FOR COMMUNICATION AND DATA SYSTEMS ARE TO

BE 4” (100MM) SQUARE COMPLETE WITH A SUITABLE PLASTER-RING.

7. ACCESS PANELS AND DOORS1. ACCESS PANELS AND DOORS TO HAVE A FIRE RATING SUITABLE FOR THE INSTALLED

LOCATION.

2. ACCESS PANELS AND DOORS TO BE PRIMED AND PAINTED, MINIMUM 12 GAUGE, FLUSH

MOUNTED WITH CONCEALED HINGES, ANCHOR STRAP, LOCK AND TRIM TO SUIT THE

MATERIAL OF THE SURROUNDING SURFACE.

3. MINIMUM SIZE TO BE 6” x 6” (150MM x 150MM) FOR HAND ACCESS

AND 24” x 18” (600MM x 450MM) FOR PERSON ACCESS.

8. SPLITTERS

1. WELDED SHEET METAL ENCLOSURE MADE FROM CODE GAUGE STEEL, PRIMED,

COMPLETE WITH SCREW-ON OR HINGED COVER FOR SURFACE MOUNTING.

2. ENCLOSURE TO BE EEMAC RATED FOR INSTALLED LOCATION.

3. INTERNAL WIRE LUGS TO MATCH SIZE REQUIREMENTS OF FEEDER AND CIRCUIT

WIRING.

4. PROVIDE A MINIMUM OF THREE (3) SPARE CIRCUIT WIRE POSITIONS ON EACH SET OF

LUGS FOR SPLITTERS RATED 600 AMP OR LESS.

5. LENGTH OF SPLITTER TO BE 12” (300MM) LONGER THAN MINIMUM NECESSARY TO

MOUNT EQUIPMENT REQUIRED FOR THE PROJECT UNLESS NOTED OTHERWISE.

10. JUNCTION AND PULL BOXES

1. SIZE AND SELECT BOXES IN ACCORDANCE WITH THE OESC FOR THE NUMBER AND

GAUGE OF CONDUCTORS CONTAINED WITHIN AND FOR THE INSTALLED LOCATION.

2. WELDED SHEET METAL ENCLOSURE MADE FROM CODE GAUGE STEEL, PRIMED AND

PAINTED AND RATED FOR THE INSTALLED LOCATION COMPLETE WITH SCREW-ON OR

HINGED COVER FOR SURFACE MOUNTING. MINIMUM SIZE TO BE 6” x 6” (150MM

x 150MM).

3. ENCLOSURE TO BE EEMAC RATED FOR INSTALLED LOCATION.

4. FLUSH MOUNTED BOXES TO BE SIMILAR TO ABOVE AND TO BE COMPLETE WITH

A 1” (25MM) TRIM TO CONCEAL WALL OR CEILING OPENING.

5. PVC BOXES TO BE USED IN CONCRETE STRUCTURES.

11. CABINETS

1. SIZE AND SELECT CABINETS IN ACCORDANCE WITH THE OESC FOR THE ENCLOSED

EQUIPMENT.

2. CABINETS AND EQUIPMENT ENCLOSURES ARE TO BE MANUFACTURED FROM CODE

GAUGE STEEL, PRIMED AND PAINTED COMPLETE WITH LOCKING DOOR, CONCEALED

HINGES AND A REMOVABLE EQUIPMENT-MOUNTING PANEL.

3. ENCLOSURE TO BE EEMAC RATED FOR INSTALLED LOCATION.

4. FLUSH MOUNTED CABINETS TO BE PROVIDED WITH APPROPRIATE TRIM AND

HARDWARE.

12. SWITCHES

1. SWITCHES SHALL BE TOGGLE STYLE, SPECIFICATION GRADE, SILENT OPERATION,

SLOW-MAKE, SLOW BREAK RATED FOR THE AMPACITY AND VOLTAGE OF THE

CONNECTED CIRCUIT.

2. SINGLE POLE UNLESS SHOWN AS KEY-OPERATED, 3-WAY OR 4-WAY ON THE DRAWINGS.

13. LED LIGHTING

1. AS SPECIFIED IN LIGHTING SCHEDULE

14. RECEPTACLES

1. GENERAL PURPOSE RECEPTACLES:

1. DUPLEX RECEPTACLES TO BE 15 AMP, 125 VOLT, U-GROUND, CSA #5-15R

CONFIGURATION. UNLESS SPECIFIED OTHERWISE ON DRAWINGS.

2. GROUND FAULT RECEPTACLES

1. DUPLEX, GROUND FAULT RECEPTACLES TO BE 15 AMP, 125 VOLT, U-GROUND, CSA

#5-15R CONFIGURATION, CLASS A, TRIP LEVEL OF 4-6MA WITH TEST AND RESET

PUSHBUTTONS.

3. EQUIPMENT RECEPTACLES:

1. EQUIPMENT RECEPTACLES TO BE RATED AS SHOWN ON THE DRAWINGS COMPLETE

WITH OUTLET BOX, MOUNTING/COVERPLATE AND ALL REQUIRED INSTALLATION

ACCESSORIES.

15. COVER PLATES

1. COVER PLATES SHALL BE PROVIDED FOR ALL OUTLET BOXES AS FOLLOWS:

1. GENERAL AREAS - SMOOTH STAINLESS STEEL

2. SERVICE AREAS - GALVANIZED STEEL

3. WET LOCATIONS - HINGED, GASKETED, GRAY LEXAN

16. DISTRIBUTION PANELS

1. LOCATION AND RATINGS AN INDICATED ON DRAWINGS.

2. THE PANEL ENCLOSURE SHALL BE CODE GAUGE STEEL, BAKED GRAY ASA61 ENAMEL

FINISH WITH A REMOVABLE FRONT COVER AND BE EEMAC RATED FOR THE INSTALLED

LOCATION. THE BUILDING IS SPRINKLERED.

3. MAIN BUS MAY BE ALUMINUM OR COPPER FOR BOLT-ON CIRCUIT BREAKERS.

4. DIRECTORY CARD IN METAL FRAME WITH PLASTIC COVER.

5. THE SHORT CIRCUIT RATING OF THE PANEL SHALL FULLY MATCH THE LOWEST RATED

BRANCH OR MAIN CIRCUIT BREAKER.

17. PANEL BOARDS

1. LOCATION AND RATINGS AS INDICATED ON DRAWINGS.

2. ENCLOSURE TO BE CODE GAUGE STEEL, BAKED GRAY ASA61 ENAMEL FINISH,

REMOVABLE FRONT COVER, LOCKING DOOR COMPLETE WITH FLUSH MOUNTED LOCK,

TWO KEYS AND TRIM FOR SURFACE OR RECESSED MOUNTING AND TO BE EEMAC RATED

FOR THE INSTALLED LOCATION.

3. MAIN BUS MAY BE ALUMINUM OR COPPER FOR BOLT-ON CIRCUIT BREAKERS.

4. DIRECTORY CARD IN METAL FRAME WITH PLASTIC COVER.

5. COMBINATION PANELS TO HAVE FACTORY INSTALLED MAIN BREAKER IN SEPARATE

COMPARTMENT AND BE RATED FOR SERVICE ENTRANCE DUTY.

6. THE SHORT CIRCUIT RATING OF THE PANEL SHALL FULLY MATCH THE LOWEST RATED

BRANCH OR MAIN CIRCUIT BREAKER.

18. DISCONNECT SWITCHES - GENERAL

1. ALL EQUIPMENT OF SIMILAR TYPE SHALL BE BY ONE MANUFACTURER.

2. ENCLOSURE TO BE EEMAC RATED FOR INSTALLED LOCATION.

3. RATINGS TO BE MINIMUM REQUIRED MATCHING THE CONNECTED EQUIPMENT LOAD

UNLESS SPECIFIED OTHERWISE ON THE DRAWINGS.

19. MOTOR DISCONNECT SWITCHES

1. FOR MOTORS RATED UP TO 1/6HP AND 120V USE SPECIFICATION GRADE 1P SWITCHES.

2. FOR MOTORS RATED UP TO 1/4HP TO 1HP AND 250V USE HOSE-POWER

RATED, SIGNLE-THROW, QUICK-MAKE/QUICK-BREAK TOGGLE SWITCHES IN FACTORY

ENCLOSURES WITH PROVISIONS TO BE LOCKED IN THE “OFF” POSITION.

3. FOR MOTORS RATED GREATER THAN 1HP AND/OR 250V USE MANUFACTURED,

HORSEPOWER RATED SAFETY SWITCHES COMPLETE WITH LOCKABLE, INTEGRAL

OPERATING HANDLE AND QUICK-MAKE/QUICK BREAK, SILVER PLATED CONTACTS.

COVER TO BE MECHANICALLY INTER-LOCKED WITH HANDLE TO PREVENT OPENING

WHEN IN THE “ON” POSITION”.

4. WHERE DISCONNECTS ARE REQUIRED TO BE FUSIBLE PROVIDE FUSE HOLDERS

SUITABLE FOR THE TYPE AND VOLTAGE OF THE FUSE INSTALLED WITH SPRING

REINFORCED FUSE CLIPS AS NECESSARY.

20. CIRCUIT DISCONNECT SWITCHES

1. FUSIBLE SWITCHES TO HAVE FUSE HOLDERS SUITABLE FOR THE TYPE AND VOLTAGE OF

THE FUSE INSTALLED WITH SPRING REINFORCED FUSE CLIPS AS NECESSARY.

21. CONTROLS - GENERAL

1. ALL EQUIPMENT OF SIMILAR TYPE SHALL BE BY ONE MANUFACTURER.

2. EQUIPMENT TO BE EEMAC RATED FOR INSTALLED LOCATION.

22. CIRCUIT BREAKERS - GENERAL

1. ALL CIRCUIT BREAKERS FOR THIS PROJECT SHALL BE BY ONE MAUFACTURER.

2. QUICK-MAKE, QUICK-BREAK WITH ARC-QUENCHING DEVICE, TRIP-FREE HANDLE,

THERMAL OVERLOAD AND INSTANTANEOUS MAGNETIC TRIP, AMBIENT TEMPERATURE

COMPENSATING TYPE.

3. MINIMUM INTERRUPTING CAPACITIES AS FOLLOWS:

1. DISTRIBUTION PANELS - 22,000 AMPERES ASYMMETRICAL

2. PANEL BOARDS (240V) - 10,000 AMPERES ASYMMETRICAL

3. PANEL BOARDS (600V) - 14,000 AMPERES ASYMMETRICAL

4. BREAKERS SHALL BE MOUNTED TO THE BUS AS FOLLOWS:

1. DISTRIBUTION PANELS - BOLT-ON DESIGN

2. PANEL BOARDS - BOLT-ON DESIGN

MULTI-POLE BREAKERS TO HAVE A COMMON/TRIP HANDLE.

20. FUSES

1. FUSES SHALL BE BY ONE MANUFACTURER THROUGHOUT THE PROJECT.

2. FEEDER FUSES UP TO 600V AND OVER 600A SHALL BE CSA CLASS HRC-L.

3. FEEDER FUSES UP TO 600V AND 600 A SHALL BE CSA CLASS HRC-J.

4. GENERAL PURPOSE CIRCUIT PROTECTION FUSES SHALL BE CSA CLASS H.

5. MOTOR AND TRANSFORMER CIRCUITS SHALL BE DUAL-ELEMENT, TIME DELAY, CSA

CLASS HRC-D.

6. FUSES 30A OR LESS MAY BE PLUG STYLE.

24. LIGHT FIXTURES

1. LIGHTING FIXTURES ARE TO BE COMPLETE WITH LAMPS, BALLASTS AND ALL MOUNTING

OR INSTALLATION ACCESSORIES FOR THE LUMINARIES INDICATED IN THE LIGHTING

FIXTURE SCHEDULE AND/OR ON THE DRAWINGS.

2. REFER TO THE ARCHITECTURAL DRAWINGS FOR DETAILS RELATING TO CEILING

AND/OR WALL ORIENTATION AND CONSTRUCTION IN ORDER TO ESTABLISH THE

PROPER REQUIREMENTS FOR HANGERS, BRACKETS, PENDANTS, BALL-JOINT SWIVEL

BASES, THREADED RODS AND OTHER SIMILAR INSTALLATION ACCESSORIES.

25. LAMPS

1. FURNISH LAMPS AS REQUIRED BY THE LIGHTING FIXTURE SCHEDULE AND THE FIXTURE

SPECIFICATION.

26. BALLASTS

1. PROVIDE BALLASTS AS REQUIRED BY THE FIXTURE SPECIFICATION AND THE LAMP

OPERATING PARAMETERS INCLUDING SPECIALIZED BALLAST AS REQUIRED FOR

DESIGNATED APPLICATIONS.

2. ALL BALLASTS ARE TO BE COMPLETELY COMPATABLE WITH THE FIXTURE/LAMP

COMBINATION SPECIFIED IN THE LIGHTING FIXTURE SCHEDULE AND LIGHTING

MANUFACTURER'S RECOMMENDATIONS.

27. EMERGENCY LIGHTING- GENERAL

1. PROVIDE EMERGENCY BATTERY UNITS AS INDICATED ON THE DRAWINGS.

2. PROVIDE LIGHTING FIXTURES WHERE INDICATED ON THE DRAWINGS.

16. EMERGENCY BATTERY UNIT

1. UNIT TO HAVE LONG LIFE (10 YEAR LIFE EXPECTANCE), SEALED LEAD/ACID, LOW

MAINTENANCE BATTERIES CAPABLE OF MAINTAINING THE CONNECTED LOAD PLUS 25%

RESERVE CAPACITY FOR A MINIMUM DURATION OF 30 MINUTES AND BE PROVIDED

WITH THE FOLLOWING FEATURES:

2. CHARGER: 100% SOLID STATE, TEMPERATURE COMPENSATING, REVERSE POLARITY

PROTECTED, AUTO-EQUALIZER CAPABLE OF RE-CHARCHING BATTERIES TO FULL

CAPACITY WITHIN 12 HOURS ABD 2 FUSED OUTPUTS.

3. TRANSFER UNIT: 100% SOLID STATE, CAPABLE OF INSTANTANEOUS TRANSFER OF

ENTIRE CONNECTED LOAD ON NORMAL POWER FAILURE OR CONNECTIONS.

4. CABINET: MINIMUM 18 GAUGE ENAMEL PAINTED STEEL ENCLOSURE WITH 1 METER

POWER CODE AND MOUNTING SHELF AS REQUIRED.

5. FEATURES: “PUSH-TO-TEST” BUTTON, AC POWER “ON” LAMP, HIGH CHARGE INDICATOR

AND BATTERY CONDITION INDICATOR.

29. EXIT LIGHT

1. ALL EQUIPMENT SHALL BE BY ONE MANUFACTURER THROUGHOUT THE PROJECT.

2. EXIT LIGHTING FIXTURE TO BE EXTRUDED ALUMINUM CONSTRUCTION, UNIVERSAL

MOUNTING, SINGLE OR DOUBLE FACE AS REQUIRED, PICTOGRAM FILMS WITH

DIRECTION INDICATION AS REQUIRED AND THE FOLLOWING FEATURES:

1. INDIRECT LED ILLUMINATION OF FACEPLATE.

2. SELF-CONTAINED ELECTRONIC COMPONENTS TO DIRECTLY ACCEPT AC AND DC POWER

INPUTS.

3. POWER CONSUMPTION SHALL BE 5W OR LESS.

31. COMMUNICATIONS- GENERAL

1. PROVIDE ALL RACEWAYS, WIRING, EQUIPMENT AND ACCESSORIES RELATING TO THE

POWER SUPPLY WIRING AS GOVERNED BY OTHER SECTIONS OF THE SPECIFICATION.

ALL ELECTRICAL MATERIAL TO BE AS RECOMMENDED BY THE EQUIPMENT/SYSTEM

SUPPLIER UNLESS SPECIFIED OTHERWISE ON THE DRAWINGS.

32. RACEWAYS THERMOSTATS

1. CONDUITS TO THERMOSTATS OUTLET BOXES INSTALLED IN WALLS TO BE

½” (12mm) UNLESS SPECIFICALLY NOTED OTHERWISE.

2. BOXES SHALL BE 2”x4” (50mm x 100mm) MOUNTED HORIZONTALLY AS REQUIRED TO

SUIT THERMOSTAT OR SENSOR UNLESS SPECIFICALLY NOTED OTHERWISE.

3. CONFIRM ALL REQUIREMENTS WITH CONTROLS CONTRACTOR PRIOR TO ROUGH-IN.

PART 3: EXECUTION

1. GENERAL REQUIREMENTS

1. ALLOW FOR THE TRANSPORTATION OF EQUIPMENT THROUGH THE CONSTRUCTION

SITE AND BUILDING. REPAIR ALL SURFACES AFFECTED BY THE MOVEMENT OF

MATERIAL.

2. CLEAN ALL EQUIPMENT IMMEDIATELY PRIOR TO FINAL INSPECTION.

2. STORAGE OF MATERIALS

1. PROVIDE A SUITABLE, ON-SITE OFFICE SPACE AND A DRY, PROTECTED STORAGE AREA

FOR MATERIAL AND EQUIPMENT TO MAINTAIN FACTORY FINISH.

2. KEEP THE SITE FREE OF DEBRIS AND SURPLUS MATERIAL.

3. UPON COMPLETION OF WORK REMOVE ALL TOOLS AND SURPLUS MATERIAL FROM SITE.

3. SLEEVING, CUTTING AND PATCHING

1. ALLOW FOR ALL SLEEVING, CUTTING, PATCHING AND PAINTING REQUIRED FOR THIS

WORK. USE ONLY SKILLED CRAFTSMAN FOR EACH TYPE OF WORK.

2. ALL HOLES THROUGH THE EXTERIOR MEMBRANE OF THE BUILDING ARE TO BE MADE

WATERPROOF. UTILIZE ACCEPTABLE METHODS OF FLASHING, CAULKING, ETC.

3. ALL HOLES IN CONCRETE AND OTHER STRUCTURAL MEMBERS ARE TO BE APPROVED BY

THE STRUCTURAL ENGINEER PRIOR TO CUTTING. THE WORK IS TO BE CARRIED OUT

UNDER THE SUPERVISION OF THE GENERAL CONTRACTOR.

4. GROUNDING AND TESTING

1. PROVIDE A COMPLETE GROUNDING SYSTEM; THERE IS NO ATTEMPT TO INDICATE ALL

OF THE GROUNDING REQUIREMENTS ON THE DRAWINGS.

2. BALANCE PHASE CURRENT SO THAT THE CURRENT ON ANY PHASE IS WITHIN 10% OF

THE MEAN VALUE.

3. TEST BONDING CONTINUITY OF METALLIC RACEWAYS.

4. TEST THE INSULATION GROUND FAULT RESISTANCE AND MERGER FEEDERS PRIOR TO

ENERGIZING.

5. TEST FOR PROPER EQUIPMENT OPERATION.

6. PROVIDE THE FOLLOWING TEST AND INCLUDE DATA IN OPERATING AND MAGNA

MANUAL

7. VOLTAGE READING AT THE FOLLOWING LOCATIONS:

1. DISTRIBUTION PANEL MAINS.

2. POWER AND/OR LIGHTING PANEL MAINS.

3. EQUIPMENT CONNECTIONS.

4. THE RECEPTACLE FURTHEST FROM THE MAIN ELECTRICAL SERVICE EQUIPMENT.

2. AMPERAGE READING AT THE FOLLOWING LOCATIONS:

1. DISTRIBUTION PANEL FEEDERS.

2. POWER AND/OR LIGHTING PANEL FEEDERS.

3. EQUIPMENT FEEDERS.

5. CORROSION, PROTECTION AND TOUCH-UP

1. PRIME AND PAINT ALL FERROUS METAL SUPPORTS, BRACKETS, ETC.

2. PROTECT ALL MATERIAL AND EQUIPMENT FROM ABUSE AND DAMAGE. REPAIR ANY

DAMAGED SURFACE TO MATCH FACTORY FINISH.

6. EQUIPMENT IDENTIFICATION

1. PROVIDE LAMACOID LABELS ON ALL DISTRIBUTION AND CONTROL EQUIPMENTS

DETAILED BELOW:

1. LABELS TO BE 1/8” (3mm) THICK WHITE BACKGROUND WITH 1/4" (6mm) BLACK

LETTERING.

2. LABELS TO CONFIRM TO WORDING SPECIFIED IN INDIVIDUAL SPECIFICATION

SECTIONS.

2. MECHANICALLY FASTEN LAMACOID LABELS TO THE EQUIPMENT WITH SELF TAPING

SCREWS IN PRE-DRILLED HOLES.

3. TEMPORARY EQUIPMENT MARKINGS SHALL BE MADE IN INCONSPICUOUS LOCATIONS

PREFERABLY ON THE INSIDE OF THE PANEL OR ENCLOSURE. ALL TEMPORARY

MARKINGS SHALL BE REMOVED PRIOR TO FINAL INSPECTION.

4. JUNCTION BOXES TO BE EXTERNALLY LABELED WITH INDELIBLE MARKER INDICATING

CIRCUITS CONTAINED INSIDE.

7. ELECTRICAL/MECHANICAL INTERFACE

1. ALL LINE VOLTAGE POWER SUPPLIES INCLUDING OVER-CURRENT PROTECTION,

OVER-LOAD PROTECTION, MOTOR STARTERS AND CONTROLLERS, LINE VOLTAGE

WIRING AND DISCONNECT MEANS SHALL BE PROVIDED UNDER THIS SECTION, EXCEPT

IN THE CASE OF UNITIZED EQUIPMENT WHERE THE MOTOR STARTERS/CONTROLLERS

FORM PART OF AN ITEM OF PACKED EQUIPMENT.

2. ALL PRESSURE SWITCHES, THERMOSTATS, SOLENOID VALVES, DAMPER MOTORS AND

SIMILAR EQUIPMENT SHALL BE FURNISHED AND INSTALLED BY MECHANICAL

SUN-CONTRACTOR FOR WIRING BY DIVISION 16.

3. OBTAIN THE ELECTRICAL RATINGS AND DATA FOR MECHANICAL EQUIPMENT, FROM THE

MECHANICAL SUB-CONTRACTOR, PRIOR TO ROUGH-IN WIRING AND CONNECTION OF

THE EQUIPMENT. REPORT ANY DISCREPANCIES BETWEEN THE SUPPLIED EQUIPMENT

AND THE RATINGS SHOWN ON THE ELECTRICAL DRAWINGS TO THE ENGINEER

WITHOUT DELAY.

4. THE MECHANICAL AND ELECTRICAL CONTRACTORS SHALL BIND THEMSELVES TO THE

ACCURACY AND COMPLETENESS OF THIS WORK, AND MUTUALLY WARRANT THE WORK

INTERFACED UNDER THESE REQUIREMENTS.

8. MOUNTING

1. PROVIDE ALL SUPPORTS REQUIRED FOR THIS WORK. EVERY CONDUIT TO HAVE AT

LEAST ONE SUPPORT AND ALL BOXES, FIXTURES, PANELS AND EQUIPMENT ARE TO BE

SUPPORTED INDEPENDENTLY OF CONNECTING CONDUITS.

2. INSTALL SWITCHES, RECEPTACLES AND OTHER OUTLETS ON A COMMON CENTRELINE

WHEN SHOWN TOGETHER.

3. MOUNTING HEIGHTS AS INDICATED ON DRAWINGS AND EQUIPMENT SCHEDULES.

4. REFER TO THE ARCHITECTURAL DRAWINGS FOR AREAS OF THE BUILDING DESIGNATED

AS BARRIER-FREE.

9. CONDUCTORS

1. INSTALL CONDUCTORS IN RACEWAYS AND TERMINATE AT EQUIPMENT OR SPLICES TO

OTHER WIRING.

2. CONDUCTORS FOR FEEDERS TO BE IDENTICAL IN TERMS OF CHARACTERISTICS AND

LENGTH AND FREE OF SPLICES.

3. USE ONLY SOLDER LESS CONDUCTORS IN APPROVED BOXES FOR SPLICES/JOINTS IN

BRANCH CIRCUIT WIRING.

10. RACEWAYS

1. INSTALL CONDUITS COMPLETE WITH ALL CONNECTORS, COUPLING, STRAPS, PULL AND

JUNCTION BOXES TO FORM A CONTINUOUS RACEWAY FOR THE INSTALLATION OF

CONDUCTORS AT A LATER TIME.

2. RACEWAYS ARE TO BE CONCEALED IN ALL FINISHED AREAS. IN SERVICE AND UTILITY

AREAS CONDUITS MAY BE EXPOSED AND SHALL BE GROUPED AND INSTALLED PARALLEL

TO BUILDING LINES. WHERE THE CONDUITS CANNOT BE INSTALLED ON BUILDING

SURFACES PROVIDE CHANNELS SURFACE MOUNTED OR SUSPENDED FROM STRUCTURAL

COMPONENTS OF THE BUILDING WITH THREADED RODS.

3. MAINTAIN REQUIRED CLEARANCES FROM STEAM OR HOT WATER LINES AND HEATING

OR OTHER SIMILAR EQUIPMENT.

4. OPENINGS FOR RACEWAYS PASSING THROUGH STRUCTURAL MEMBERS OR LARGER

THAN 1 1/4" (32mm) IN CONCRETE SLAB MUST BE REVIEWED AND APPROVED BY THE

STRUCTURAL ENGINEER PRIOR TO INSTALLATION.

5. EMPTY CONDUITS AND RACEWAY SYSTEM CONDUITS SHALL BE PROVIDED COMPLETE

WITH BOXES, COVER PLATES, BUSHINGS, CAPS AND PULL-CORDS.

6. PROVIDE FULL BOXES IN COMMUNICATIONS CONDUIT SYSTEMS AS DIRECTED BY THE

COMMUNICATIONS CABLE INSTALLER.

7. PROVIDE CONDUIT SEALS WHERE REQUIRED BY THE OESC.

11. CABLES

1. CABLES ARE TO BE INSTALLED AS PER MANUFACTURER'S RECOMMENDATIONS TO

ACHIEVE DESIRED AMPERE RATING OF THE CONDUCTORS.

2. FEEDER CABLES ARE TO BE FREE OF SPLICES.

3. SINGLE CONDUCTOR CABLES ARE TO BE SECURED WITH NON-FERROUS STRAPS OR

CLIPS AT INTERVALS REQUIRED BY THE OESC TO A FLAT BUILDING SURFACE OR

FABRICATED SUPPORT ASSEMBLY.

4. SECURE MULTIPLE CONDUCTOR CABLES TO STRUCTURAL COMPONENTS OF THE

BUILDING USING APPROVED METHODS. TIE-WIRE NOT ACCEPTABLE.

5. MULTIPLE CONDUCTOR, ARMORED CABLES MAY BE USED FOR FINAL CONNECTIONS TO

LIGHTING FIXTURES OR EQUIPMENT AND FOR BRANCH CIRCUIT WIRING CONCEALED

MAXIMUM EXPOSED LENGTH SHALL BE 10'-0” (3000mm).

6. STANDARD OUTLET BOXES

1. ALL BOXES ARE TO BE FLUSH MOUNTED EXCEPT IN SERVICE AND UTILITY AREAS.

2. GANG BOXES WHEREVER DEVICES ARE SHOWN TOGETHER. WHEN ADJACENT BOXES

CANNOT BE GANGED INSTALL ON COMMON CENTERLINE IN EITHER A HORIZONTAL OF

VERTICAL ORIENTATION.

3. SECURE OUTLET BOXES INDEPENDENTLY FROM CONNECTING CONDUITS.

4. CONFIRM MILLWORK, FURNITURE AND DOOR SWINGS FROM ARCHITECTURAL

DRAWINGS PRIOR TO ROUGH-IN.

5. FILL UN-USED KNOCKOUT OPENINGS WITH PURPOSE-MADE FILLERS.

INSTALL BLANK COVER PLATES ON ALL UNUSED OUTLET BOXES.

11. BACKBOARDS

1. PROVIDE BACKBOARDS FOR THE MOUNTING OF MAIN ELECTRICAL SERVICE EQUIPMENT,

WHERE SHOWN ELSEWHERE ON THE DRAWINGS.

2. PROVIDE SELF SUPPORTING FRAMEWORK WHERE THERE IS INSUFFICIENT WALL SPACE

TO MOUNT THE EQUIPMENT OR THE ADJACENT STRUCTURE IS NOT CAPABLE OF

SUPPORTING THE WEIGHT OF THE EQUIPMENT.

14. ACCESS PANELS AND DOORS

1. PROVIDE ACCESS PANELS OR DOORS WHERE REQUIRED FOR ACCESS TO ELECTRICAL

EQUIPMENT INSTALLED AS PART OF THIS WORK OR FOR EXISTING EQUIPMENT

CONCEALED AS PART OF THE WORK OF OTHER TRADES.

2. PROVIDE ALL PANELS, DOORS AND FRAMES TO THE APPROPRIATE DIVISION FOR THE

INSTALLATION AT THE COST IF THIS DIVISION.

3. PAINTING OF THE DOORS SHALL BE BY OTHERS.

16. SPLITTERS

1. FURNISH AND INSTALL SPLITTERS IN A NEAT, LOGICAL ARRANGEMENT SQUARE TO

BUILDING LINES ON BACKBOARDS OR METALLIC STRUCT/CHANNELS.

2. CONNECT TO POWER SUPPLY FEEDER. THE FEEDER WIRING IS TO BE IDENTIFIED (BY

PHASE) AND TERMINATED AT THE LUGS WITH NO EXCESS LENGTH.

3. PREPARE THE SPLITTER FOR THE INSTALLATION OF CIRCUIT DISCONNECT SWITCHES,

COMBINATION STARTERS, ETC.

17. JUNCTION AND PULL BOXES

1. SUPPLY AND INSTALL PULL AND JUNCTION BOXES IN RACEWAY SYSTEMS AS REQUIRED

TO INSTALL THE CONDUCTORS.

2. INSTALL BOXES IN INCONSPICUOUS BUT ACCESSIBLE LOCATIONS, USUALLY IN

ACCESSIBLE CEILING SPACES OR IN SERVICE AND UTILITY AREAS. PROVIDE DRYWALL

ACCESS PANELS AS REQUIRED.

3. SECURE BOXES INDEPENDENT OF CONNECTING CONDUITS.

4. JUNCTION BOXES TO BE LABELED WITH PERMANENT MARKER INDICATING CIRCUITS

CONTAINED INSIDE.

18. CABINETS

1. FURNISH AND INSTALL CABINETS FOR THE INSTALLATION OF ELECTRICAL

COMPONENTS INCLUDED IN THIS WORK OR COVERED BY A DIFFERENT SPECIFICATION

OR FOR THE FUTURE INSTALLATION OF EQUIPMENT BY OTHERS.

2. MOUNT BACKBOARDS OR METALLIC STRUCT/CHANNELS.

3. PRIME FLUSH MOUNTED CABINETS IN FINISHED AREAS FOR FINISHED PAINTING BY

OTHERS.

4. BOXES TO BE LABELED WITH DATA INDICATING EQUIPMENT CONTAINED INSIDE.

19. DEVICES

1. INSTALL ELECTRICAL DEVICES IN OUTLET BOXES CONNECT TO POWER SUPPLY AND/OR

CONTROL WIRING AND AFFIX COVER PLATE OVER DEVICE AND OUTLET BOX.

2. REFER TO THE ARCHITECTURAL DRAWINGS TO DETERMINE THE BARRIER-FREE AREAS

OF THE BUILDING AND POSITION THE DEVICES AT THE MOUNTING HEIGHT THAT IS

APPROPRIATE FOR THE DESIGNATION OF THE INSTALLED LOCATION.

3. REFER TO ARCHITECTURAL MILLWORK DRAWINGS TO DETERMINE THE EXACT

CONSTRUCTION DETAILS OF THE MILLWORK PRIOR TO ROUGH-IN. POSITION THE

DEVICES IN SUCH A MANNER SO THAT THEY ARE NOT BLOCKED BEHIND THE UNITS OR

REQUIRE THE COVER PLATES TO BE FIELD MODIFIED TO ALLOW THEM TO BE

INSTALLED.

4. INSTALL SWITCHES AND RECEPTACLES OR OTHER OUTLETS WITH DIFFERENT

MOUNTING HEIGHTS ON AN COMMON CENTERLINE WHEN SHOWN TOGETHER.

5. DO NOT MOUNT DEVICES BACK TO BACK.

6. REPLACE ANY DEVICES OR COVER PLATES THAT HAVE BEEN DAMAGED OR MARKED BY

PAINT CONSTRUCTION.

20. SWITCHES

1. INSTALL SINGLE POLE SWITCHES SO THAT SWITCH IS CLOSED WITH THE TOGGLE IN

THE UP POSITION.

2. GROUP SWITCHES TOGETHER IN A COMMON OUTLET BOX WITH A MATCHING MULTIPLE

GANG COVER PLATE WHERE TWO OR MORE ARE SHOWN IN ONE LOCATION.

21. RECEPTACLES

1. IN GENERAL, RECEPTACLES SHALL BE INSTALLED VERTICALLY SO THAT LINE AND

NEUTRAL OPENINGS ARE ABOVE GROUND PRONG.

2. GANG RECEPTACLES TOGETHER IN COMMON OUTLET BOX WHERE TWO OR MORE ARE

SHOWN IN ONE LOCATION.

3. INSTALL RECEPTACLES HORIZONTALLY WHERE REQUIRED TO CLEAR MILLWORK OR

FURNITURE.

4. INSTALL OUTDOOR, WEATHERPROOF RECEPTACLES HORIZONTALLY.

22. COVER PLATES

1. MOUNT COVER PLATES FLUSH TO WALL FOR RECESSED DEVICES.

2. PROVIDE BLANK COVER PLATES ON ALL UNUSED DEVICE OUTLET BOXES.

3. INSTALL COVER PLATES AFTER PAINTING IS COMPLETED, WHERE IT IS TO BE

INSTALLED ON A PAINTED SURFACE.

23. DISTRIBUTION PANELS

1. INSTALL PANEL ON A FIRE-RATED BACKBOARD AND/OR A SELF-SUPPORTING

FRAMEWORK WHERE THERE IS INSUFFICIENT WALL SPACE TO MOUNT THE PANEL OR

THE STRUCTURE IS NOT CAPABLE OF SUPPORTING THE WEIGHT OF THE PANEL(S).

2. CONNECT TO POWER SUPPLY FEEDER. THE FEEDER WIRING IS TO BE IDENTIFIED (BY

PHASE) AND TERMINATED AT THE LUGS WITH NO EXCESS LENGTH.

3. COMPLETE A TYPE WRITTEN PANEL DIRECTORY AND INSTALL IN FRAME.

4. PROVIDE LABEL ON THE PANEL COVER INDICATING PANEL NAME ON ONE LINE WITH

FEEDER AMPERES, VOLTAGE, PHASE AND WIRES ON A LINE

BELOW (E.G. “DP-1, 400A, 347/600V, 3PH, 4W”). REFER TO DRAWINGS FOR PANEL

IDENTIFICATION.

24. DISCONNECT SWITCHES

1. FURNISH AND INSTALL DISCONNECT SWITCHES COMPLETE WITH FUSES AND CONNECT

TO POWER SUPPLY WIRING TO THE CONNECTED LOAD.

2. MOUNT ALL EQUIPMENT IN NEAT, LOGICAL ARRANGEMENT. WIRING TO BE LABELED

AND TERMINATED AT RIGHT ANGLES TO THE DEVICE OR EQUIPMENT WITH NO EXCESS

LENGTH.

3. PROVIDE A SELF-SUPPORTING FRAMEWORK WHERE THERE IS INSUFFICIENT WALL

SPACE TO MOUNT THE EQUIPMENT OR ADJACENT STRUCTURE IS NOT CAPABLE OF

SUPPORTING THE WEIGHT OF THE DISCONNECT(S).

4. PROVIDE LAMACOID LABELS ON CIRCUIT DISCONNECTS INDICATING CONNECTED

LOADS, VOLTAGE RATING AND MAXIMUM FUSE SIZE ON THREE (3) SEPARATE

LINES (E.G. “HVAC-1, *208/3*, MAX FUSE 20A).

25. CONTROLS

1. FURNISH AND INSTALL CONTROL ACCESSORIES AS INDICATED ON THE DRAWINGS AND

REQUIRED BY THIS SPECIFICATION. CONNECT TO POWER SUPPLY AND CIRCUIT WIRING

TO ACHIEVE THE CONTROL DESIRED.

2. MOUNT ALL EQUIPMENT IN A NEAT, LOGICAL ARRANGEMENT. WIRING TO BE LABELED

AND TERMINATED AT RIGHT ANGLES TO THE DEVICE OR EQUIPMENT WITH NO EXCESS

LENGTH.

3. PROVIDE WIRING DIAGRAMS FOR CONTROL CIRCUITS AND MOUNT INSIDE COVER OF

EQUIPMENT ENCLOSURE.

4. TEST ALL CONTROL SEQUENCES AND CONFIRM PROPER OPERATION PRIOR TO FINAL

INSPECTION.

26. CIRCUIT BREAKERS

1. PROVIDE CIRCUIT BREAKERS AS INDICATED ON THE PANEL SCHEDULES AND/OR SINGLE

LINE DIAGRAMS.

2. ENSURE THAT ALL BREAKERS HAVE AN INTERRUPTING CAPACITY SUITABLE FOR THE

APPLICATION.

3. TERMINATE BRANCH CIRCUIT WIRING IN THE BREAKER LUG. WIRING TO BE LABELED

AT RIGHT ANGLES TO THE CIRCUIT BREAKER WITH NO EXCESS LENGTH.

27. FUSES

1. FUSES FOR FEEDERS TO BE AS INDICATED ON THE DRAWINGS.

2. FUSES FOR MOTOR AND TRANSFORMER CIRCUITS TO BE BASED ON THE NAMEPLATE

RATING OF THE EQUIPMENT.

3. ENSURE THAT ALL FUSES ARE CORRECTLY RATED FOR THE APPLICATION.

4. SHIP FUSES IN THEIR ORIGINAL CONTAINERS AND INSTALL IN DISCONNECT SWITCHES

AND/OR SWITCHBOARDS IMMEDIATELY PRIOR TO ENERGIZING CIRCUIT.

5. PROVIDE THREE (3) SPARE FUSES OF EACH SIZE AND TYPE RATED 200A OR GREATER.

6. PROVIDE SIX (6) SPARE FUSES OF EACH SIZE AND TYPE RATED LESS THAN 200A.

7. HAND OVER SPARE FUSES (IN ORIGINAL CONTAINERS) TO THE OWNER UPON

COMPLETION OF THE PROJECT.

28. LIGHTING

1. REVIEW ALL AVAILABLE DRAWINGS AND EXISTING SITE CONDITIONS (AS APPLICABLE)

TO ENSURE THAT THE FIXTURE IS COMPLETE WITH ALL OF THE REQUIRED MOUNTING

HARDWARE AND ACCESSORIES.

2. INSTALL LIGHTING FIXTURES COMPLETE WITH ALL LAMPS, TRIM AND MOUNTING

HARDWARE AND CONNECT TO POWER SUPPLY AND CONTROL WIRING AS INDICATED

ON THE DRAWINGS FOR A COMPLETE AND FINISHED UNIT(S).

3. INSTALL LIGHTING FIXTURES IN MECHANICAL AND OTHER SERVICE ROOMS AFTER THE

MECHANICAL AND ELECTRICAL EQUIPMENT IS IN PLACE. LOCATE LUMINARIES TO CLEAR

ALL OBSTRUCTIONS. PROVIDE ADDITIONAL SUPPORT TO HANG FIXTURES BELOW

DUCTS AND EQUIPMENT.

4. ENSURE FIXTURES ARE INSTALLED IN SUCH A MANNER AS TO FACILITATE THE

REPLACEMENT OF LAMPS.

5. PROVIDE ALL SUPPORT BLOCKING AS NECESSARY FOR THE INSTALLATION OF LIGHTING

FIXTURES. SUPPORTS SHALL BE CONCEALED BEHIND WALLS OR ABOVE CEILINGS.

6. LIGHTING FIXTURES INSTALLED IN ACOUSTIC TILE CEILINGS ARE TO BE SUPPORTED

INDEPENDENTLY FROM THE CEILING GRID IN A MINIMUM OF TWO LOCATIONS BY

CHAIN CONNECTED TO THE BUILDING STRUCTURE.

29. EMERGENCY LIGHTING

1. FURNISH AND INSTALL BATTERY LIGHTING UNITS AND REMOTE FIXTURES COMPLETE

WITH ALL REQUIRED ACCESSORIES AND MOUNTING HARDWARE FOR A COMPLETE AND

FUNCTIONAL INSTALLATION.

2. CONNECT TO LINE AND/OR LOW VOLTAGE POWER SUPPLIES. UTILIZE WIRING

METHODS AND SIZE CONDUCTORS FOR VOLTAGE DROP AS ALLOWED BY THE OESC.

3. ENSURE FIXTURES ARE INSTALLED IN SUCH A MANNER AS TO FACILITATE

REPLACEMENT OF LAMPS. AIM FIXTURES TO PROVIDE OPTIMUM COVERAGE OF FLOOR

AREAS.

4. UTILIZE WIRING METHODS AND SIZE CONDUCTORS FOR VOLTAGE DROP AS ALLOWED

BY OESC.

5. TEST OPERATION OF ALL EQUIPMENT PRIOR TO FINAL INSPECTION.

6. PROVIDE DUPLEX RECEPTACLES ON LOCAL LIGHTING CIRCUIT ADJACENT TO BATTERY

UNIT UNLESS DETAILED OTHERWISE ON THE DRAWINGS.

30. EXIT LIGHTING

1. PROVIDE FIXTURES WHERE INDICATED ON THE DRAWINGS.

2. FURNISH AND INSTALL ALL FIXTURES COMPLETE WITH ALL LAMPS, TRIM AND

MOUNTING HARDWARE FOR A COMPLETE AND FINISHED APPEARANCE.

3. PROVIDE ALL SUPPORT BLOCKING AS NECESSARY FOR THE INSTALLATION OF LIGHTING

AND BATTERY UNITS.

4. CONNECT LINE AND LOW VOLTAGE POWER SUPPLIES. UTILIZE WIRING METHODS AND

SIZE CONDUCTORS FOR VOLTAGE DROP AS ALLOWED BY OESC.

5. TEST OPERATION OF ALL EQUIPMENT PRIOR TO FINAL INSPECTION.

6. WHERE AN EXIT LIGHT FIXTURE IS SHOWN AT A DOOR ON THE DRAWINGS MOUNT

FIXTURE ON WALL 6” (150mm) ABOVE THE DOOR AND ON THE CENTERLINE OF THE

DOOR.

31. MECHANICAL EQUIPMENT

1. INSTALL POWER SUPPLY WIRING AND CONNECT TO MECHANICAL EQUIPMENT.

2. ALL LINE VOLTAGE POWER SUPPLIES INCLUDING OVER-CURRENT PROTECTION,

OVER-LOAD PROTECTION, MOTOR STARTERS/CONTROLLERS, LINE VOLTAGE WIRING

AND LOCAL DISCONNECTING MEANS SHALL BE PROVIDED UNDER THIS SECTION,

EXCEPT IN THE CASE OF UNITIZED EQUIPMENT WHERE THE MOTOR

STARTERS/CONTROLLERS FORM PART OF THE PACKED EQUIPMENT.

3. OBTAIN THE ELECTRICAL RATINGS AND DATA FOR MECHANICAL EQUIPMENT, FROM THE

MECHANICAL CONTRACTOR, PRIOR TO ROUGH-IN AND CONNECTION OF THE

EQUIPMENT. REPORT ANY DISCREPANCIES BETWEEN THE SUPPLIED EQUIPMENT AND

THE RATINGS SHOWN ON THE ELECTRICAL DRAWINGS TO THE ENGINEER WITHOUT

DELAY.

4. THE MECHANICAL AND ELECTRICAL CONTRACTORS SHALL BIND THEMSELVES TO THE

ACCURACY AND COMPLETENESS OF THIS WORK, AND MUTUALLY WARRANT THE WORK

INTERFACED UNDER THESE REQUIREMENTS.

32. MOTORIZED OVERHEAD DOORS

1. INSTALL POWER SUPPLY WIRING AND CONNECT TO MOTORIZED DOOR OPERATOR.

2.

PROJECT NUMBER

DRAWN CHECKED

SCALEDATE

FILE NAME

DRAWING

DATEDESCRIPTIONREV.

This drawing is the property ofSPH Engineering Inc. and is not tobe copied or distributed for anyreason or by any means withoutthe permission of the owner.

DRAWING

PROJECT

CLIENT

FAX: 519-539-5775TEL: 519-539-5700

SPH ENGINEERING INC.REAL WORLD ENGINEERING SOLUTIONS

N4S 8V8WOODSTOCK, ONTARIO

UNIT #165 SPRINGBANK AVE. N.

18134GMImainM4

STAMP NORTH ARROW

DATE

ISSUED FORPRELIMINARYCLIENT REVIEWSITE PLAN APPROVAL

BUILDING PERMITTENDERCONSTRUCTION

2018-10-01

.

Toll Free: 1-877-392-9766

Tel: (519) 842-4392

49 North Street East , Tillsonburg , ON N4G 1B4

email:[email protected]

Fax: (519) 688-2470

CONSTRUCTION LTD.

Grassmere

ww

w.g

rass

me

re.c

om

design-build construction services

R. W. SPENCER

RE

G

IS

T

E

R

E

D

P

R

O

F

ESS

IO

N

A

L

E

N

G

IN

EE

R

P

R

O

V

I

N

C

E

OF

O

N

T

A

R

I

O

100191633

2018-10-01

2018-04-12

GG RS

AS NOTED

18134

ELECTRICALSPECIFICATIONS

PROPOSED ADDITIONSGMI BUILDING

BEARDS LANE, WOODSTOCK, ON

E6

N