Products Catalog - FRONTEC

34
Products Catalog 2015 MADE TO MAKE IT WELL DONE.

Transcript of Products Catalog - FRONTEC

Page 1: Products Catalog - FRONTEC

ProductsCatalog

2015

MADE TO MAKE IT WELL DONE.

Page 2: Products Catalog - FRONTEC

MISSIONTurn the need for xing and tying in practical, safe andeconomical experience.

• ISO/TS 16949:2009• ISO 9001:2008 • CRCC

CERTIFICATIONSCOPE

INTRODUCTION

Page 3: Products Catalog - FRONTEC

05

TechnicalInformation

We produce cable ties and fasteners withdifferent types of polymers, which have specific

features and an indication of use for variousenvironments.

SUMMARYTechnical Information

Standard Cable ties

Cable ties Accessories

Special Cable ties

Stainless Steel Cable ties

Fasteners

Cable Organizers

Heat Shrinkables

Connectors and Terminals

05

11

16

21

29

35

40

43

57

Page 4: Products Catalog - FRONTEC

06 07

Technical Information

Raw material technical parameters

Polyamide 6.6 propertiesPolyamides are thermoplastic synthetic materials that can be molded by heating without providing chemical decomposition or other changes in their properties. They are also known as Nylon, name used by Dupont, who synthesized the first polyamide in 1935 by the chemist Wallace Hume Carothers.Polyamide 6.6 has features that allow the manufacture of cable ties and fasteners with high tensile strength, mechanical strength; and desirable flexibility and surface hardness. It is the most common polyamide in the manufacture of FRONTEC cable ties and fasteners, because its characteristics are suitable for a high range of applications.PA 6.6 molecules are composed of two basic units with six carbon atoms in each of them:

Polyamide 4.6 propertiesPolyamide 4.6 has a high heat resistance without the need for adding special additives. It is used in the manufacture of FRONTEC cable ties and fasteners for use in environments with temperatures up to 135 °C with peaks up to 150 °C.PA 4.6 molecules are composed of two basic units with four carbon atoms in one of them and six in the other:

Moisture index in polyamidesThe polyamides are hygroscopic materials, they absorb and release water. The moisture level of the cable ties is very important, because it affects their flexibility and their tensile strength.Polyamide 6.6 stabilizes its moisture index around 2.5% when subjected to a controlledatmosphere of 23 °C and 50% relative air humidity.The time required for the cable ties to acquire this moisture content ranges from 7 to 50 days depending on the dimensions of the piece.When the cable ties are used, the ideal is that its moisture content is around 2.5%.Once applied, once the trigger will be static in the grooves of the cable tie body, the changes in moisture index will not cause significant changes in the mechanical properties of the parts.FRONTEC cable ties and fasteners are packed in suitable plastic bags and are only sold in themarket when its moisture index is around 2.5%. For this reason, it is recommended that products are kept in their original packages and used as soon as the packages are open.It is also recommended that, during the storage of cable ties and fasteners, the products do not suffer exposure to sun rays or are stored near heat sources.The ideal storage should be at 23 ° C with relative air humidity of 50%.

Cable ties with protection againstultraviolet rays (UV)

The cable ties in the natural color (page 12) are not suitable for applications with exposure to sunlight for long periods of time.The cable ties in black (page 12) are doped with carbon black and, therefore, have a goodresistance to ultraviolet rays (UV). Experience has shown good performance in sun exposureof up to 3 years.The cable ties with UV protection (page 13) are doped with special components that providegreater resistance to weathering and ultraviolet rays (UV), being indicated for applicationsexposed to sunlight for higher time.They are tested according to the ASTM G155:13 standards, that simulates a condition ofapproximately 10 years exposure to weather.The cable tie features (tensile strength, color,flexibility and texture) should remain unchanged after subjected to this test.To identify whether a cable tie in black has UV resistance or not, a faster and simpler assaycan be done, consisting in tuning a part of the cable tie tape (between 0.2 and 0.3 mm) andlook to the light through this area.The cable tie with UV protection does not allow light topass through and the cable tie without UV protection is a little t ranslucent in tuned area.

[-NH(CH2)6NH - CO(CH2)4CO-]

[-NH(CH2)4NH - CO(CH2)4CO-]

UV Protection No UV Protection

Material Operating Temperature Flammability Properties of the material

Nylon 6.6 (PA6.6) -40ºC 85ºC UL94 V2

- high traction and abrasion resistance.- high mecanical resistance;- excellent flexibility and surface hardness.

Nylon 6.6 UV estabilizado a

raios ultravioleta (PA6.6 UV)

-40ºC 85ºC UL94 V2

- similar characteristics to PA 6.6,but resistant to ultraviolet rays.- recommended for use in environments exposedto sunlight.

Nylon 6.6 HS estabilizado

ao calor (PA6.6 HS)

-40ºC 105ºC UL94 V2

- similar characteristics to PA 6.6, but with addeddurability at constant hight temperature applications;- recommended for close to vehicular engineapplications.

Nylon 6.6 V0 (PA6.6 V0) -40ºC 85ºC UL94 V0

- similar characteristics to PA 6.6, and complywith UL 94V0 standard and low levels of toxic gas and acids generated by the fire.

Nylon 4.6 (PA 4.6)

-40ºC 135ºC(picos de até 150ºC) UL94 V2

- excellent chemical resistance;- higher rigidity and dimensional stability, even at hight temperatures.

Page 5: Products Catalog - FRONTEC

08 09

Technical Information

For proper preservation of thecable tie, it is recommended tostorage at a temperature between 10 and 40 °C and relative air humidity between 30% and 70%.

The cable tie must be used assoon as possible after openingthe packaging (plastic bag) if the humidity is below 30%.

Avoid keeping the cable tie near heat sources, as this maychange the humidity of cableties and its features.

Do not place or expose the cable ties in the ultraviolet (UV) rays, as they may change their structure, making them fragile.

Temperature resistanceThe polyamides used for manufacturing cable ties are sensitive to high or low temperatures.Exposure to very high or low temperatures can break the molecular chain, causing low mechanical strength, fragility and sensitivity to vibration.The maximum temperature recommended for the installation of Polyamide 6.6 cable tie is 60 °C, however the maximum temperature of continuous use is 85 ºC.The minimum temperature for the use of polyamide 6.6 cable ties is -40 °C. However, when they are applied, it is recommended that the temperature is above -10 °C.When the cable ties are used in high temperature regime, it is recommended the use of cable ties produced with heat-stabilized polyamide 6.6 (PA 6.6 HS) or produced from polyamide 4.6.

FlammabilityThe most popular standard for assessing the behavior of polymers against the flame is the UL 94 (Underwriters Laboratories).This test classifies the material based on the speed of combustion, the flame extinction time and the trend of flame propagation by dripping.Classification begins with the HB class, lower level, which identifies the material as low burning rate.V2, V1 and V0 classes identify materials as self-extinguishing.

HB (horizontal burning)- According to UL 94, the material is classified as HB, considering two test samples:• Combustion of 38.1 mm/in for a 3.2 mm thick specimen.

• Combustion of 63.5 mm/ min for a <3.2 mm thick specimen.

V2 (vertical burning) - The flame is extinguished within 30 seconds with dripping.

V1 (vertical burning) - The flame is extinguished within 30 seconds without dripping.

V0 (vertical burning) - The flame is extinguished within 10 seconds without dripping.

Traction resistanceAll cable ties lots produced by FRONTEC are tested by sampling.The results are available in reports containing the values obtained in each test.The minimum breakdown voltage is the load that a cable tie must support without the occurrence of its break.

TraceabilityAll products manufactured by FRONTEC have individual traceability for production batch, covering the various stages of the production process with the following information:

• Lot of raw materials (including the vendor’s report);• Used machine;• Operator and time of manufacture;• Injection parameters used in the manufacture;• Data from the gravimetric distributor informing the dosages of the raw material components;• Records with date and time of testing, verification, inspection, wastes, operators, setup and stops in the production;• Release report issued by the quality sector;• Storage location in stock;• Data related to the separation and billing (who separated the order, date, invoice number, customer etc.).

The chart above represents the traction resistance test performed on 10 samples of the cable tieF7040.The minimum break voltage expected is 54.4 kgf and the result showed values close to 80 kgf (the result was 47% higher than specified in the catalog).

Cable ties preservation

The mandrel opens withconstant speed.

The load at which the cable tiebreaks down is measured andrecorded in software thatprovides the test data in chartsas shown on the next page.

The cable tie is fixed on amandrel with a diameterdefined for each cable tiemodel.

Strenght (Kgf)

Sample

Minimum Strenght

Page 6: Products Catalog - FRONTEC

11

Foto de abertura21 x 18 cm

1110

Resistance to chemicalsChemicals such as acids, bases, salts, alcohols, phenols, gas, among others, may deteriorate the raw material used in the cable tie,changing its properties and life cycle. See the table of chemicals resistance.

Good - good resistance without changes in weight and volumeAverage – average resistance with a significant loss of weight and volume if used for a long timeLimited - limited resistance, can be used for a short period of timeLow - low resistance. The material is very worn out.

Chemical agent Conc. Resist.Acetaldehyde - aqueous solution 40% averageAcetamide - aqueous solution 50% goodAmyl acetate 100% goodButyl acetate 100% 100% goodMethyl acetate 100% goodLead acetate - water solution 10% averageAcetone 100% goodAcetic acid - concentrated lowAcetic acid - aqueous solution 10% lowBenzoic acid - saturated aqueous solution averageBóric acid - aqueous solution 10% averageButyric acid 100% averageCitric acid - aqueous solution 10% limitedHydrochloric acid - aqueous solution 2% limitedHydrochloric acid - aqueous solution 10% lowHydrochloric acid - aqueous solution 36% solubleChromic acid - aqueous solution 1% averageChromic acid - aqueous solution 10% lowFormic acid - aqueous solution 10% lowFormic acid - aqueous solution 85% solublePhthalic acid - aqueous solution 10% lowLactic acid - aqueous solution 10% averageLactic acid - aqueous solution 90% lowNitric acid lowOleic acid 100% good Oxalic acid - aqueous solution 100% goodSalicílic acid 10% averageSulfuric acid - concentrated 100% goodSulfuric acid - aqueous solution 98% solubleSulfuric acid - aqueous solution 2% limitedTartaric acid 10% lowTartaric acid - aqueous solution averageWater (marine / of river / drinkable / distilled) 10% goodClorinated water goodAcrylonitrile averageFusel oil 100% goodButyl alcohol 100% goodBenzyl alcohol 100% averageEthanol / ethyl alcohol 100% limitedIsopropyl alcohol 96% averageMethyl alcohol averagePropyl alcohol 100% averageAmmonia averageAmmonia - gas 10% goodAcetic anhydride - concentrated limitedAniline solubleBenzaldehyde 100% averageBenzene 100% limitedMercuric chloride - aqueous solutiona 100% goodPotassium bichromate - aqueous solution 6% lowSodium bisulfate - aqueous solution 5% averageBitumen 10% goodPotassium bromide - aqueous solutiona averageBrometo de sódio - aqueous solution 10% averageButane 10% averageButyl phthalate goodCamphor goodPotassium carbonate 100% goodSodium carbonate - aqueous solution 100% goodCyclohexane 10% goodChlorine gas 100% goodChlorine gas 100% goodClorobenzene 100% lowClorobromometano goodChloroform 100% low averageClorofórmio 100% low

Chemical agent Conc. Resist.Aluminum choride - aqueous solution 10% goodBarium chloride - aqueous solution 10% goodCalcium chloride - aqueous solution 10% goodCalcium chloride - aqueous solution 20% solubleEthyl chloride 100% averageMethyl chloride 100% limitedMagnesium chloride - aqueous solution 10% goodSodium chloride - aqueous solution 10% goodThionyl chloride lowVinyl chloride 100% goodZinc chloride 10% averageFerric chloride - aqueous solution 10% goodDecalin goodDiacetone alcohol goodEthylene dichloride goodDiethanolamine goodDimethylformamide 100% goodAcetic ether 100% goodEthyl ether 100% goodGlycol ether goodHeptane goodHexane averagePhenol - aqueous solution solubleFormaldehyde - aqueous solution 30% goodFormamide averageSodium phosphate - aqueous solution 10% goodButyl glycol 100% averageAmmonium hydroxide - aqueous solutioon 10% goodMagnesium hydroxide - aqueous solution 10% goodPotassium hydroxide - aqueous solutioon 5% goodPotassium hydroxide - aqueous solution 10% goodPotassium hydroxide - aqueous solutioon 50% averageSodium hypochlorite - aqueous solution goodIsooctane goodMercury goodMethyl ethyl ketone goodMethyl isobutyl ketone goodNafteno goodPotassium nitrate - aqueous solution 10% goodSodium nitrate - aqueous solution 5% goodNitrobenzene 100% averageNitromethane 100% averageMineral oil goodZinc oxide goodOctyl phthalate goodOzone lowPerchlorethylene lowHydrogen peroxide - aqueous solution 0,5% limitedHydrogen peroxide - aqueous solution 1% lowHydrogen peroxide - aqueous solution 3% lowHydrogen peroxide - aqueous solution 30% lowPetroleum goodMagnesium salts - aqueous solution 10% goodCopper salts - aqueous solution 10% goodCaustic soda - aqueous solution 5% goodCaustic soda- aqueous solution 10% goodCaustic soda - aqueous solution 50% averageAluminium sulphate - aqueous solution 10% goodCopper sulphate - aqueous solution 10% goodSodium sulphate - aqueous solution 10% goodCarbon disulfide 100% goodHydrogen sulfide - aqueous solution lowLead stearate 100% goodCarbon tetrachloride goodTrichlorethylene average

StandardCable ties

We make various cable ties sizes and with different polymers, acColording to the best use

indication.We produce with the best materials via the injection of the next generation.

Page 7: Products Catalog - FRONTEC

12 13

Abraçadeiras Convencionais

Standard Cable tie 6.6Material: PA 6.6Use temperature: 40 °C to 85 °CFlammability: UL94 V2

PA Cable tie 6.6 Resistantto weathering (UV)Material: PA 6.6 with anti-UV additivesUse temperature: -40°C to 85°CFlammability: UL94 V2

FRONTEC manufactures a nylon cable ties line specially developed to resist UV and weathering.They can be used for long periods of time exposed to the sun (over 10 years).These cable ties are produced with Nylon 6.6 and additives that prevent the disruption of the molecular structure of the piece, providing resistance when used outdoors.The sun resistant cable ties are tested in accordance with ASTM G155 13 standard.

Group Lenght Xwidth (mm)

Complete Reference Color Ø Maximum Bundle

Minimum Tensile StrenghtKgf lbs N

F7008 82 X 2,3 F7008NYNA natural 16

8,2 18 60

F7008NYPR black

F7010 108 X 2,5 F7010NYNA natural 22F7010NYPR blackF7014 140 X 2,5 F7014NYNA natural 33

F7019 209 X 2,5 F7019NYNA natural 55F7019NYPR black

F7015 151 X 3,7 F7015NYNA natural 37

13,6 30 135

F7015NYPR black

F7020 202 X 3,7 F7020NYNA natural 51F7020NYPR blackF7031 300 X 3,6 F7031NYNA natural 76F7037 370 X 3,6 F7037NYNA natural 102

F7012 125 X 4,8 F7012NYNA natural 28

22,7 50 225

F7012NYPR black

F7023 200 X 4,8 F7023NYNA natural 51F7023NYPR black

F7024 238 X 4,8 F7024NYNA natural 60F7024NYPR black

F7028 283 X 4,8 F7028NYNA natural 76F7028NYPR black

F7039 400 X 4,8 F7039NYNA natural 114F7039NYPR black

F7030 300 X 7,6 F7030NYNA natural 8054,4 120 535F7030NYPR black

F7040 398 X 7,6 F7040NYNA natural 110F7040NYPR black

F7053 535 X 8,8 F7053NYNA natural 147

68 150 670

F7053NYPR black

F7076 765 X 8,8 F7076NYNA natural 220F7076NYPR black

F70109 1095 X 8,8 F70109NYNA natural 330F70109NYPR black

F7054 536 X 13,7 F7054NYNA natural 147 115 250 1115F7054NYPR black

Lenght Xwidth (mm)

Complete Reference Color Ø Maximum Bundle

Minimum Tensile StrenghtKgf lbs N

82 X 2,3 F7008UVPR black 16

8,2 18 80108 X 2,5 F7010UVPR black 22

209 X 2,5 F7019UVPR black 55

151 X 3,7 F7015UVPR black 3713,6 30 135

202 X 3,7 F7020UVPR black 51

125 X 4,8 F7012UVPR black 28

22,7 50 225

200 X 4,8 F7023UVPR black 51

238 X 4,8 F7024UVPR black 60

283 X 4,8 F7028UVPR black 76

400 X 4,8 F7039UVPR black 114

300 X 7,6 F7030UVPR black 8054,4 120 535

398 X 7,6 F7040UVPR black 110

535 X 8,8 F7053UVPR black 147

68 150 670765 X 8,8 F7076UVPR black 220

1095 X 8,8 F70109UVPR black 330

536 X 13,7 F7054UVPR black 147 115 250 1115

Page 8: Products Catalog - FRONTEC

14 15

Abraçadeiras Convencionais

Group Lenght Xwidth (mm)

Complete Reference Color Ø Maximum Bundle

Minimum Tensile StrenghtKgf lbs N

F7010

108 X 2,5 F7010UVAM yellow

22 8,2 18 80108 X 2,5 F7010UVAZ blue108 X 2,5 F7010UVLA orange108 X 2,5 F7010UVVD green108 X 2,5 F7010UVVM red

F7015

151 X 3,7 F7015UVAM yellow

37 13,6 30 135151 X 3,7 F7015NYAZ blue151 X 3,7 F7015UVLA orange151 X 3,7 F7015UVVD green151 X 3,7 F7015UVVM red

F7023

200 X 4,8 F7023UVAM yellow

51

22,7 50 225

200 X 4,8 F7023NYAZ blue200 X 4,8 F7023NYLA orange200 X 4,8 F7023UVVD green200 X 4,8 F7023UVVM red

F7028

283 X 4,8 F7028UVAM yellow

76283 X 4,8 F7028UVAZ blue283 X 4,8 F7028UVVD green283 X 4,8 F7028UVVM red

F7039

400 X 4,8 F7039UVAM yellow

114400 X 4,8 F7039UVAZ blue400 X 4,8 F7039UVVD green400 X 4,8 F7039UVVM red

F7040

398 X 7,6 F7040UVAM yellow

110 54,4 120 535398 X 7,6 F7040UVAZ blue398 X 7,6 F7040UVVD green398 X 7,6 F7040UVVM red

Group Lenght Xwidth (mm)

Complete Reference Color Ø Maximum Bundle

Minimum Tensile StrenghtKgf lbs N

F7015 151 X 3,7 F7015NYAZ blue 37 13,6 30 135

F7023 200 X 4,8 F7023NYAZ blue 51 22,7 50 225200 X 4,8 F7023NYLA orange

Lenght Xwidth (mm) Complete Reference Ø Maximum Bundle

Minimum Tensile StrenghtKgf lbs N

82 X 2,3 F7008HSPR 168,2 18 80108 X 2,5 F7010HSPR 22

209 X 2,5 F7019HSPR 55151 X 3,7 F7015HSPR 37 13,6 30 135202 X 3,7 F7020HSPR 51125 X 4,8 F7012HSPR 28

22,7 50 225200 X 4,8 F7023HSPR 51238 X 4,8 F7024HSPR 60283 X 4,8 F7028HSPR 76400 X 4,8 F7039HSPR 114300 X 7,6 F7030HSPR 80 54,4 120 535398 X 7,6 F7040HSPR 110535 X 8,8 F7053HSPR 147

68 150 670765 X 8,8 F7076HSPR 2201095 X 8,8 F70109HSPR 330536 X 13,7 F7054HSPR 147 115 250 1115

Lenght Xwidth (mm)

Complete Reference Color Ø Maximum Bundle

Minimum Tensile StrenghtKgf lbs N

108 X 2,5 F7010NY4.6 black 22 8,2 18 80209 X 2,5 F7019NY4.6 black 55151 X 3,7 F7015NY4.6 black 37 13,6 30 135202 X 3,7 F7020NY4.6 black 51125 X 4,8 F7012NY4.6 black 28

22,7 50 225200 X 4,8 F7023NY4.6 black 51238 X 4,8 F7024NY4.6 black 60283 X 4,8 F7028NY4.6 black 76400 X 4,8 F7039NY4.6 black 114300 X 7,6 F7030NY4.6 black 80 54,4 120 535398 X 7,6 F7040NY4.6 black 110535 X 8,8 F7053NY4.6 black 147

68 150 670765 X 8,8 F7076NY4.6 black 2201095 X 8,8 F70109NY4.6 black 330536 X 13,7 F7054NY4.6 black 147 115 250 1115

Color Cable Ties Resistantto weathering (UV)Material: PA 6.6 with anti-UV additivesUse temperature: -40°C to 85°CFlammability: UL94 V2

Color Cable Ties without UV protection

PA Cable tie 6.6 for High Temperature (HS)Material: Nylon 6.6 HSUse temperature: -40°C to 105°CFlammability: UL94 V2

This cable ties line is produced from heat-stabilized polyamide 6.6 and injection parameters for use in environments subject to constant temperature regimes near 100 °C.

Abraçadeiras PA 4.6 para altas temperaturasMaterial: Nylon 4.6Use temperature: -40 °C to 135 °C with peaks of 150 ºC Flammability: UL94 V2

This cable s line is produced from polyamide 4.6 and injection parameters for use in environments subjected to constant high temperature regimes.

Page 9: Products Catalog - FRONTEC

17

Cable ties Accessories

16

Cable tiesAccessoriesThese are products that increase productivity and securing the efficiency of various components when used together with conventional cable ties.

Items with EA adhesive have 34% more grip that items with EAA adhesive.Items with PL adhesive have 264% more grip that items with EAA adhesive.

AdhesiveLevel of adherence

REF Base color Width ofcable ties (mm)Indoors Outdoors Epoxi paint

EAA very good very good goodF7801EAA natural

até 4,8F7802EAA natural / blackF7803EAA natural até 7,6

EA great great goodF7801EA * natural

até 4,8F7802EA * natural / blackF7802UVEA * natural with UV protection

PL excellent excellent excellentF7802PL ** natural até 4,8F7803PL ** natural até 7,6

Adhesive FastenersThese fasteners, when used with conventional cable ties, allow the cables, hoses and other components lashing without the need for drilling. Adhesives are of excellent quality and can be used indoors and outdoors.Before the application of the fastener, it is recommended to clean the surface with isopropyl alcohol so that it will stay clean, dry and uniform.When the surface is very smooth you may need to make a small abrasion.When using adhesive fasteners EA and EAA, you may need the primer from 3M reference 8215 P to improve the adherence in surfaces with epoxy paint.The PL adhesive fasteners do not require primer.

F7801 F7802 F7803

* Adhesive 3M** 3M Primer Less adhesive

INTENSITY OF ADHERENCE

Level of adherence

Application time

1 hour 1 day 3 days20 min

Page 10: Products Catalog - FRONTEC

18 19

Cable ties Accessories

AB

D

C

AB

C

Material Color Operating Temperature Flammability

Nylon 6.6 (PA 6.6) Natural / black -40ºC a 85ºC UL94 V2Nylon 6.6 UV (PA 6.6 UV) White / black -40ºC a 85ºC UL94 V2

Material Color Operating Temperature Flammability

Nylon 6.6 HS (PA 6.6 HS) Black -40ºC a 105ºC UL94 V2

REF Base (mm) Height (mm) Ø of hole (mm) Type of cable ties

F7808 * 15 X 10 7 3,4 All models with a width of up 4,8 mmF7809 ** 22 X 15 9,25 5,1 All models with a width of up 8,8 mmFSA7802 28 X 28 6 6 All models with a width of up 4,8 mm

Material Color Operating Temperature Flammability

Nylon 6.6 UV (PA 6.6 UV) Black -40ºC a 85ºC UL94 V2

Material Color Operating Temperature Flammability

Nylon 6.6 (PA 6.6 ) Natural / black -40ºC a 85ºC UL94 V2

REF A (mm) B (mm) C (mm) D (mm) E (mm) Ø of hole (mm) Type of cable ties

F7821 12,5 38,5 10 9,5 2,5Soft materials: 8 mmHard materials: 9 mm

Very hard materials: 9,5 mm

All models with a widthof up 8,5 mm

REF A (mm) B (mm) C (mm) D (mm) Ø of hole (mm) Sheet thickness Type of cable ties

F7830 9,5 16,6 7,5 3,3 6,4 Max 3 mm All models with a widthof up 3,7 mm

Fasteners without adhesivesThese fasteners were developed for binding wires, cables and electrical harnesses in different surfaces by screws or rivets, with the use of a conventional cable tie.

PlugsThis fastener model is designed to be used with a conventional cable tie with width up to 4.8 mm.It has the body formed by parallel blades, which increases the fixing quality and performance, as they require low to high power for placement and extraction.It is very easy for tying electrical harnesses and other components to plates (flat hole) or steel blocks (threaded hole).

FRONTEC also offers the plugs with cable ties already placed.Refer to item: “Plug assembled with cable tie (FP)”, page 22.

FRONTEC also provides the bushing with the cable tie.Refer to item: “Bushing with cable tie”, page 27.

* Can be applied with 6 mm screw/bushing and supports up to 32 kgf.* Can be applied with 6 to 8 mm screw/bushing and supports up to 50 kgf.

BushingThis product speeds up the installation of wires, cables, hoses and pipes in concrete, solid brick or wood walls. The bushing is inserted into the hole with a hammer, preferably a rubber hammer, and does not require screw fixation. The bushing provides support for mooring by conventional cable ties. When the bushing is exposed to sunlight, it is recommended the use of cable ties with UV protection (page 13).

Clip for plates attachmentThis clip used with a conventional cable tie, allows a quick, easy and economic attachment in plates, of wires and cables. Without using screws or rivets.

REF A (mm) B (mm) C (mm) Ø of hole (mm) Sheet thickness Type of cable ties Drawing

FP6L 16 5 10,7 6,5 a 7 orthereaded hole M8 0,8 a 6 mm With a width of

up to 4,8 mm

FP7 16 5 12,7 6,5 a 7 orthereaded hole M8 0,8 a 7 mm With a width of

up to 4,8 mm

FP8 16 5 11,1 7,7 a 8 orthereaded hole M10 0,8 a 6 mm With a width of

up to 4,8 mm

Page 11: Products Catalog - FRONTEC

2120

Clip for attachment in rectangular cutoutsThis fastener has a socket to attach relays, and a hole for the insertion of conventional cable ties with width up to 4.8 mm.

Material Color Operating Temperature Flammability

Polyacetal (impact modified) Black -40ºC a 100ºC UL94 HB

REF Furo (mm) Sheet thickness Maximum insertion force Minimum extraction force

FC8X15 8,0 X 15,0 0,7 a 2,1 mm 5,0 kgf 70,0 kgf

Ref Height(mm)

Diameter(mm) Color Type of cable ties

FSUP 8,1 12 Black Até 4,8 mm

Bracket for two bindingsMaterial: PA 6.6 Operating Temperature: 40°C to 85°CFlammability: UL94 V2

This piece allows the use of two parallel cable ties to secure and separate two bindings. Theclamps can rotate at an angle of up to 90° differently from one another. Very useful for separating hoses and avoiding friction wear.

Ref: FSUP

SpecialCable ties

These cable ties are used in the automotive industry because they increase performance and

quality of different binding processes, making them safer and economic.

Page 12: Products Catalog - FRONTEC

22 23

Special Cable ties

Cable ties with fixing plug The FRONTEC manufactures a range of cable ties with fixing plug already in the part. The plug is built with a technology that enables the use of the product with low insertion force and high extraction force, enabling quality and performance in the binding of electrical harnesses or other components.

Cable ties for threaded pin bindingThis clamp is designed for binding electrical harnesses or other components directly on screws or threaded pins.

Plug assembled with cable tie (FP)This product is used with cable ties width up to 4.8 mm for binding electrical harnesses or other components. The fixing blades have a design that enhances the quality and performance of the binding, it has low insertion force and high extraction force.

Material Color Operating Temperature FlammabilityNylon 6.6 HS (PA 6.6 HS) Natural / black -40ºC a 105ºC UL94 V2

Nylon HS IM (PA 6.6 HS IM) Black -40ºC a 105ºC UL94 V2

Material Color Operating Temperature FlammabilityNylon 6.6 HS (PA 6.6 HS) Natural / black -40ºC a 105ºC UL94 V2

Nylon HS IM (PA 6.6 HS IM) Black -40ºC a 105ºC UL94 V2

Produto Material Color Operating Temperature Flammability

Cable tieNylon 6.6 (PA 6.6) Natural / black -40ºC a 85ºC UL94 V2

Nylon 6.6 HS (PA 6.6 HS) Natural / black -40ºC a 105ºC UL94 V2Plug Nylon 6.6 HS (PA 6.6 HS) Black -40ºC a 105ºC UL94 V2

REFLenght (mm)

Width (mm) Ø máx oflashing (mm)

Minimum Tensile Strenght Threaded pin bindingBody Head Kgf Lbs N

FM56 8023 187 25,4 6,20 51 22,7 50 225 M5 ou M6FM8 8023 187 25,9 6,20 51 22,7 50 225 M8

head

plug

body

body

REFCable tie Plug

Height (mm)

Ø máx oflashing(mm)

Minimum tensileStrenght Plate hole

diameter (mm)Plate

thickness(mm)

PlugLenght (mm) Width

(mm) Kgf Lbs N

FP6L 7010 108 2,5 10,7 22 8,2 18 80 6,5 a 7 or threaded hole M8 0,8 a 6FP6L 7015 151 3,7 10,7 37 13,6 30 135 6,5 a 7 or threaded hole M8 0,8 a 6FP6L 7023 200 4,8 10,7 51 22,7 50 225 6,5 a 7 or threaded hole M8 0,8 a 6FP7 7010 108 2,5 12,7 22 8,2 18 80 6,5 a 7 or threaded hole M8 0,8 a 7FP7 7015 151 3,7 12,7 37 13,6 30 135 6,5 a 7 or threaded hole M8 0,8 a 7FP7 7023 200 4,8 12,7 51 22,7 50 225 6,5 a 7 or threaded hole M8 0,8 a 7FP8 7015 151 3,7 11,1 37 13,6 30 135 7,7 a 8 or threaded hole M10 0,8 a 6

FP8 7023 200 4,8 11,1 51 22,7 50 225 7,7 a 8 or threaded hole M10 0,8 a 6

REFLenght (mm) Width

(mm)Ø máx oflashing(mm)

Minimum tensileStrenght Plate hole

Platethickness

(mm)Plug

Body Plug Kgf Lbs N

F5 8023 198 7 4,8 51 22,7 50 225 Ø 5 mm orthreaded hole M6 0,7 a 3

F6 8023 198 9,3 4,8 51 22,7 50 225 Ø 6,3 a 7 mm orthreaded hole M8 0,7 a 2,5

F6L 8023 198 15 4,8 51 22,7 50 225 Ø 6,3 a 7 mm orthreaded hole M8 0,7 a 7

F8 8023 198 17,5 4,8 51 22,7 50 225 Ø 8 ± 0,25 mm orthreaded hole M10 0,7 a 7

FOB 8023 198 11,1 4,8 51 22,7 50 225 6,2 x 12,2 mm 0,7 a 6

Ordinary Knurled

Reverse knurled

F6I 8023 198 9,3 4,8 51 22,7 50 225 Ø 6,3 a 7 mm orthreaded hole M8 0,7 a 2,5

Page 13: Products Catalog - FRONTEC

24 25

Special Cable ties

Cable tie with eyeThis cable tie model is useful for cable, hoses and other components fixing by screws and rivets.

Cable ties with plugThis clamp has the fixing plug away from the head. It is very useful when the tying have to get a little displaced from the hole where the plug is.

Cable tie with fixing clipThese cable ties have a fixing clip in arrow shape and are widely used for the attachment harness or hoses in metal plates.

Cable ties with double headAppropriate for fixing two whips or components using two loops.

plug

eye bolt

clip

body

body

body

Material Color Operating Temperature FlammabilityNylon HS (PA 6.6 HS) Natural / black -40°C a 105°C UL94 V2

Material Color Operating Temperature FlammabilityNylon 6.6 (PA 6.6) Natural / black -40ºC a 85ºC UL94 V2

Nylon HS (PA 6.6 HS) Black -40ºC a 105ºC UL94 V2Nylon 6.6 V0 (PA V0) White -40ºC a 85ºC UL94 V0

REFLenght (mm) Width

(mm)Ø máx oflashing(mm)

Minimum tensileStrenght Plate hole

Platethickness

(mm)Body Plug Kgf Lbs N

FT58023 200 25,4 6,2 45 22,7 50 225 ø 5mm or threaded hole M6 0,7 a 3,5

REFLenght (mm)

Width (mm) Ø máx oflashing (mm)

Ø of hole(mm)

Minimum Tensile StrenghtEye bolt Body Kgf Lbs N

FO8023 12,5 187,5 4,8 45 5,2 22,7 50 225

REF Lenght (mm) Width(mm)

Ø máx oflashing (mm)

Ø mín oflashing (mm)

Minimum Tensile StrenghtKgf Lbs N

FCD7023 195 4,8 a: 47 b: 45 a: 2,5 b: 2 22,2 49 218

REFLenght (mm) Width

(mm)Ø máx oflashing(mm)

Minimum tensileStrenght Plate hole

diameter (mm)Plate

thickness(mm)

ClipClip Body Kgf Lbs N

FC7010 5,5 100 2,5 19 8 18 80 4,75 ± 0,1 3 máx

FC7013 8,5 135 4,8 24 22,7 50 225 6,3 ± 0,2 0,8 a 2,7

FC7014 8,5 135 4,8 24 22,7 50 225 4,7 ± 0,1 3,2 a 4

Material Color Operating Temperature FlammabilityNylon HS (PA 6.6 HS) Natural / black -40ºC a 105ºC UL94 V2

Material Color Operating Temperature FlammabilityNylon 6.6 (PA 6.6) Natural -40ºC a 85ºC UL94 V2

Page 14: Products Catalog - FRONTEC

26 27

Special Cable ties

Bushing with Cable tieThis product facilitates the attachment of wires, cables and tubes in concrete, brick and wood walls. The bushing provides support for mooring by conventional cable ties.

Seal with limiterThis product was developed to improve tracking systems, where the use of plastic or paper labels is necessary, and has the following characteristics:

• Basis for sequential recording of up to 11 digits;• Sealing function;• Limiter to avoid damaging the label.

Cable tie with clip and central fixingMaterial: PA 6.6 Operating Temperature: 40°C to 85°CFlammability: UL94 V2

This clamp allows the fixation of cables, hoses and other components centrally, regardless of its diameter. It has claws on part of the belt to prevent the volume slip tied in the cable tie strap and the side flaps that keep the clip pressed in the drilling.

Cable ties reutilizáveisThese pieces have a latch that allows its reuse. Suitable for organizing telephone and logicnetworks.

Cable tie for chassisThis piece is widely used for the attachment of harness and hoses along bus and trucks chassis.The tape of the cable tie connects the harness or the component to be fixed and goes to the headof the part where it gives the lock (on the other side of the chassis).

Material Color Operating Temperature FlammabilityNylon 6.6 (PA 6.6) Natural -40ºC a 85ºC UL94 V2

REF Measures of cable tie Lenght of clip Ø of plate hole Plate thickness Ø máx of lashing

FCT8023 209 X 4,7 mm 6,4 mm 6,4 ± 0,1 mm 0,6 a 3,0 mm 50 mm

Material Color Operating Temperature FlammabilityNylon 6.6 Black -40ºC a 85ºC UL94 V2

REF Lenght (mm) Width (mm)Ø máx oflashing(mm)

Minimum Tensile Strenght

Kgf Lbs N

FRE7015 150 7,6 35 22,2 48 217FRE7025 250 7,6 66 22,2 48 217

REF Lenght (mm) Width(mm)

Ø máx oflashing (mm)

Ø of hole(mm)

Minimum Tensile StrenghtKgf Lbs N

F7300 300 6 80 7 a 12 18 40 180

Material Color Operating Temperature FlammabilityNylon 6.6 UV (PA 6.6 UV) Black -40°C a 85°C UL94 V2

REF Lenght (mm) Width(mm)

Ø máx oflashing (mm)

Ø of hole(mm)

Minimum Tensile StrenghtKgf Lbs N

FB7040 398 7,6 110 8 for soft materials9 ou 9,5 for hard materials 54,4 120 535

REF A (mm) B (mm) C (mm) D (mm) Ø máx of lashing(mm)

Minimum Tensile StrenghtKgf Lbs N

FL7027 280 32,2 5,2 13 39 13,6 30 135

A

B

D

C

Material Color Operating Temperature FlammabilityNylon 6.6 HS (PA 6.6 HS) Natural / black -40ºC a 105ºC UL94 V2

Nylon 6.6 (PA 6.6) Natural, black and colors -40ºC a 85ºC ULV4 V2

Number engraving only.

Page 15: Products Catalog - FRONTEC

2928

Identification Cable tiesThese cable ties have a basis for engraving identification or labeling.

Tools for polyamide cable ties

Material Color Operating Temperature FlammabilityNylon 6.6 (PA 6.6) Natural -40°C a 85°C UL94 V2

REF Lenght (mm) Width(mm)

Marker(mm)

Ø máx oflashing (mm)

Minimum Tensile StrenghtKgf Lbs N

FMTI7010 100 2,5 25,4 X 8 18 8,2 18 80

FMTE7010 112 2,5 20,4 X 9,1 18 8,2 18 80

FMHI7023 190 4,8 13 X 28 46 22,2 49 218

FMHI7039 370 4,8 13 X 28 102 22,2 49 218

Width of cable tie (mm) Level of strenght2,5 23,7 24,8 3

widht ofcable tie (mm)

Level of strenght

2,5 1

3,7 1

4,8 6

widht ofcable tie (mm)

Level of strenght

7,6 2

8,8 3

A12001-0(professional)Manual tool by AveryDennison company.Use: cable ties withwidth of up to 4.8 mm

F8005Manual tool.Use: cable ties withwidth of up to 4.8 mm

F8006Manual tool.Use: tools with width of 7.9mm or 8.8 mm

A12500-0(professional)Pneumatic tool by AveryDennison company.Use: cable ties with widthof up to 4.8 mm

Stainless SteelCable ties

We manufacture the most complete line of stainlesssteel cable ties with locking system by lock and ball. We can also deliver cable ties in the most

appropriate length for each project.

Page 16: Products Catalog - FRONTEC

30 31

Stainless Steel Cable ties

REF Lenght (mm) Width (mm) Ø máx oflashing (mm)

Minimum Tensile StrenghtKgf Lbs N

FA0127 127 4,6 25

100 220 980

FA0201 201 4,6 50FA0259 259 4,6 69FA0362 362 4,6 102FA0521 521 4,6 152FA0681 681 4,6 203FA0838 838 4,6 254FA0998 998 4,6 304FA1156 1156 4,6 355FA1205 1205 4,6 370

FAL0201 201 7,9 50

225 496 2206

FAL0259 259 7,9 69FAL0362 362 7,9 102FAL0521 521 7,9 152FAL0681 681 7,9 203FAL0838 838 7,9 254FAL0998 998 7,9 304FAL1156 1156 7,9 355FAL1205 1205 7,9 370

FALL0434 434 12,7 122

300 661 2942

FALL0594 594 12,7 173FALL0754 754 12,7 224FALL0912 912 12,7 275FALL1072 1072 12,7 325FALL1205 1205 12,7 370

REF Lenght (mm) Width (mm) Ø máx oflashing (mm)

Minimum Tensile StrenghtKgf Lbs N

FARP 0127 127 4,6 25

100 220 980

FARP 0201 201 4,6 50FARP 0259 259 4,6 69FARP 0362 362 4,6 102FARP 0521 521 4,6 152FARP 0681 681 4,6 203FARP 0838 838 4,6 254FARP 0998 998 4,6 304FARP 1156 1156 4,6 355FARP 1205 1205 4,6 370

FALRP 0201 201 7,9 50

225 496 2206

FALRP 0259 259 7,9 69FALRP 0362 362 7,9 102FALRP 0521 521 7,9 152FALRP 0681 681 7,9 203FALRP 0838 838 7,9 254FALRP 0998 998 7,9 304FALRP 1156 1156 7,9 355FALRP 1205 1205 7,9 370

FALLRP 0434 434 12,7 122

300 661 2946

FALLRP 0594 594 12,7 173FALLRP 0754 754 12,7 224FALLRP 0912 912 12,7 275FALLRP 1072 1072 12,7 325FALLRP 1205 1205 12,7 370

Material Operating Temperature

Stainless steel AISI 316 -80ºC a 538ºC

Material Operating TemperatureStainless steel AISI 316 withcoated strip with polyester -40ºC a 150ºC

We produce any size perfect for yourproject “just in time”

We produce any size perfect for yourproject “just in time”

Stainless Steel Cable ties without coatingFRONTEC stainless steel cable ties were created to be used in severe environment and conditions and present the following characteristics:

• High mechanic and chemicals resistance;• Allow the fixation of the most different materials andobjects;• Does not loosen with vibrations;• May be used in cases of extreme temperature and in highly corrosive environments;

• Present high strength and hardness in the loops;• Are installed with easy and have rounded corners that do not hurt the operator or the components beingaffixed.

• Are installed very easily;• Are fully covered, avoiding chemical battery.

Polyester Coated Stainless SteelCable Ties

Polyester coated stainless steel cable ties are specially indicated for naval application when are tied with materials with distinctive chemical characteristics. They have high resistance to corrosion and weathering.

• Do not hurt the operator and fixed components;• Good UV resistance;• AISI 316 Steel;

Page 17: Products Catalog - FRONTEC

32 33

Stainless Steel Cable ties

Material Color Operating Temperature FlammabilityFlame retardant Polyethylene with UV Black -40ºC a 90ºC Flame retardant classification UL94-V0

REF Width (mm) A (±0,3) B (±0,3) C (±0,3) D PackageFITA4,6PE 4,6 3,2 6,5 1,4 9,3 25 mFITA7,9PE 7,9 3,7 10,5 1,4 13,3 25 m

FITA12,7PE 12,7 4,7 16,7 1,4 19,5 25 m

REF Lenght (mm) Width (mm) Ø máx oflashing (mm)

Minimum Tensile StrenghtKgf Lbs N

FALD20470 470 7,9 51

272 600 2670FALD20711 711 7,9 102FALD20863 863 7,9 127FALD21016 1016 7,9 152FALLD20749 749 12,7 102

363 800 3560FALLD21054 1054 12,7 152FALLD21359 1359 12,7 203

REF Lenght (mm) Width (mm) Type of cable tie Number of charactersFAIG10X90 90 10 With width up to 7,9 mm Up to 18 charactersFAIG20X90 90 20 With width up to 7,9 mm Up to 32 characters (2 lines with 16 each)

REF Width (mm) Lenght of the strip in the box (m)Minimum Tensile Strenght

Kgf Lbs NFA4,6FITA 4,6 50 100 220 980FAL7,9FITA 7,9 50 225 496 2206

FALL12,7FITA 12,7 50 300 661 2946

REF Width (mm) Comprimento da fita na caixa (m)Minimum Tensile Strenght

Kgf Lbs NFARP4,6FITA 4,6 50 100 220 980FALRP7,9FITA 7,9 50 225 496 2206

FALLRP12,7FITA 12,7 50 300 661 2946

REF Lock for strip - width (mm) Quantity per box (pieces)FARP4,6FITA 4,6 100FALRP7,9FITA 7,9 100

FALLRP12,7FITA 12,7 100

Material Operating TemperatureStainless Steel AISI 316 -80ºC a 538ºC

Material Operating TemperatureStainless Steel AISI 316 -80ºC a 538ºC

Protecting tape for Stainless Steel Cable tiesThe use of stainless steel cable ties with protective tape give the tying:

• Separation of metals with different characteristics avoiding chemical battery;• Absorption of small return, characteristic of the type of closure by ball used,eliminating the slack in the tying point;• Protection of the edges of the cable tie.

Stainless steel clamps with doubleloop uncoated

The body of the clamp passes twice through the head providing a significant increase in minimum tensile strength.

Stainless steel markers- Already Engraved

Used to identify cables and pipes in harsh environments such as oil rigs, ships, petrochemicalindustry, shipbuilding, steel works, railways, subways, mines, among others. Design with lowered holes to facilitate passage of the cable tie.

Uncovered

With polyester cover

Lock

Stainless Steel Cable ties in coil This product is suitable for applications where it is not possible to determine in advance the required lengths. The tape and the lock are produced in stainless steel AISI 316 and packaged to facilitate their storage and use.

Page 18: Products Catalog - FRONTEC

3534

The cutting is done by moving thecable tie of the lever.

F8003Manual tool.

F8004Hand tool for finishing of stainless steel cable tie.

F8001Manual tool.

EnforcementCable ties with a width of up to 7.9 mm.

EnforcementCable ties with a width of up to 12.7 mm.

EnforcementCable tie with width up to 12.7 mm.

Tools for Stainless Steel Cable ties

It has a button to adjust the voltageaccording to the width of the cable tie.The use allows the constant tensioningand cutting of the cable tie close to thehead.

FastenersThese products allow the attachment of

various components in a fast, safe,economical and durable way.

Page 19: Products Catalog - FRONTEC

36 37

Fasteners

Two types of adhesives, EA and EAA are provided, both of which have high quality and can be used on internal and external environments. Before applying the clip it is recommended that the surface is cleaned with isopropyl alcohol.

Adhesive ClipThis product is suitable for the attachment of hoses and cables with diameter of approximately 13 mm.

Directing plugsThis product consists of a plug and a cable duct where the electrical harness can be placed. The plug has the form of several parallel fins that make the insertion quick and very efficient.

*3M adhesive

Tree Clip This clip is an excellent product for fixing trim panels in the automotive and furniture industry.

Plug for finishingThis piece allows the attachment of two surfaces, one by the plug and the other by the head piece. It is used to attach the part with foam of benches at its base, for example, bus seats benches.

REF Measures(mm)

Ø of clip(mm)

F7813EAA 23,5 X 24 13

F7813EA * 23,5 X 24 13

C

B

A

Material Color Operating Temperature FlammabilityNylon 6.6 HS (PA 6.6 HS) Black -40ºC a 105ºC UL94 V2

REF A (mm) B (mm) C (mm) Plate hole diameter (mm) Plate thickness (mm)F1291 36,3 11,1 9,7 6,5 a 6,7 0,6 a 5,1

REF A (mm) B (mm) C (mm) Ø of hole (mm) F7822 7,8 33,7 20 6,8 a 7,2

REF A (mm) B (mm) Ø of hole (mm) Plate thickness (mm) F7823 14,7 13 8 3,5

Material Color Operating Temperature FlammabilityNylon 6.6 (PA 6.6) Grey and Black -40ºC a 85ºC UL94 V2

Material Color Operating Temperature FlammabilityNylon 6.6 (PA 6.6 ) Cinza e Black -40ºC a 85ºC UL94 V2

*Outras Colores sob consulta.

*Outras Colores sob consulta.

B

A

A

B

C

Level of adherence

Application time

1 hour 1 day 3 days20 min

Page 20: Products Catalog - FRONTEC

38 39

Fasteners

Alligator Cable tiesThis cable tie has two sets of teeth that fit into one another when they are tightened together. It is very useful for joining two plastic hoses.

Self-locking clipFixation of the hose from the hydraulic system of Fiat cars.

FGM4 FGM3 FGM2 FCGM2

The FR items have setting that enable fixing cables and hoses of various diameters.

Cable fastenersThey are very useful products for the attachment of harnesses, pipes of oil and gas and otheritems.With few items you can make bindings with various diameters.

Candle cable fastenersEnforcement:Fixation of the GM car spark plug wires.

Material Color Operating Temperature FlammabilityNYLON 66 (PA 66) com fibra de vidro Black -40ºC a 148ºC UL94 V2

Material Color Operating Temperature FlammabilityNylon 6.6 (PA 6.6) Black -40°C a 85°C UL94 V2

REF Thickness (mm) Width (mm) Ø mín of lashing (mm) Ø máx of lashing (mm) FJ7718 1,8 6 19,8 22,8

REF Plate thickness (mm) Ø máx for accommodation (mm) FCA12 0,5 a 1,3 12

Material Color Operating Temperature FlammabilityNylon 6.6 (PA 6.6 ) Natural e Black -40ºC a 85ºC UL94 V2

Material Color Operating Temperature FlammabilityNylon 6.6 HS (PA 6.6 HS) Black -40ºC a 105ºC UL94 V2

REF Ways Plate thickness (mm) Fixing rips (mm) Ø of hole (mm)FGM2 2 1,3 a 1,7 6,4 a 8 5 a 7

FGM3 3 1,3 a 1,7 6,4 a 8 5 a 7

FGM4 4 1,3 a 1,7 6,4 a 8 5 a 7

FCGM2 2 5 a 7

REF Ø of cable (mm) Width (mm) Lenght (mm)F7901 4,8 9,5 18,1F7902 6 11 21,8F7903 8 11 22,5F7904 10,3 12,3 26,2F7906 14,5 12,3 30,3

FR7908 12,7 a 15,9 12,9 31FR7911 15,9 a 20,6 12,7 36FR7914 20,6 a 25,4 15,9 48,2FR7916 27 a 31,8 19,2 56,4FR7918 33,3 a 38,1 19,1 63

Page 21: Products Catalog - FRONTEC

41

Cable Organizers

40

CableOrganizers

Spiral tubeFRONTEC spiral tubes have flexibility, wall thickness and cutting standard that provide its fast and easy handling. It is an excellent product for tying and accommodation of harnesses, allowing the derivation at any point of it.

grey yelloworange blackwhite clear

*Produzidos sob encomenda.

Material Color Operating Temperature Flammability

Polyethylene White, black, grey and colors -40ºC a 80ºC UL94 HB

Polyethylene AC (chame retardant) * Grey -40ºC a 80ºC UL94 V0

Polyethylene UV (ultraviolet protection) * Black -40ºC a 80ºC UL94 HB

Teflon (antichamas) * Clear -80ºC a 260ºC UL94 V0

REF Ø external (pol) Ø external (mm) Ø máx of lashing (mm) PackageF7118 1/8 4,8 3,2 a 12,5

50 m5 m1 m

F7114 1/4 6,5 5 a 50F7138 3/8 9,5 8 a 80F7112 1/2 11,2 9,5 a 101F7158 5/8 15,9 11,5 a 105F7134 3/4 18 17 a 150F 7101 1 23 23 a 200

Page 22: Products Catalog - FRONTEC

4342

Self-fixable Cable tiesRecoverable tying system, especially developed for applications such as: optical fiber cables,computer networks, product identification etc.Ideal for temporary applications in which a constant opening is required. Very simple usage, as it does not use any kind of tool.

Wire markersWire markers are ideal for identifying wires and cables. The angled cut enables the maintenance of the set alignment and its design enables a single marker model to be used in various gauges of wires or cables.

L

C

REF Lenght C (mm) Width L (mm) Package

FVGT 150 150 12 5 pieces

FVGT 200 200 12 5 pieces

Material Color Print

PVC Flexible Yellow printed in black Letters A - Z

Numbers 0 - 9

Symbols + - \ /

REF Cable size Metric series (mm2) Amount of pieces per package

FGT 0 18 AWG - 12 AWG 0,75 - 2,5 100

FGT 1 18 AWG - 10 AWG 0,75 - 4 100

FGT 2 12 AWG - 8 AWG 2,5 - 6 100

FGT 3 8 AWG - 6 AWG 6 - 10 50

Heat ShrinkablesThey are tubes produced with reticulated

polyolefin pipe which shrink when subjected to heat, causing electrical isolation.

Page 23: Products Catalog - FRONTEC

44 45

Heat Shrinkables

Shrink Tubes with low voltage (1 kV)Standard wall - Shrink 2:1

• Meets RoHS and Sony standard• Material = flexible polyolefin• Use temperature = -55 ºC a 125 ºC• Shrink Temperature = starts at 70 °C and ends at 120 °C• Flammability = UL VW-1• Longitudinal shrinkage of less than 8%• Supplied in coils

The measures highlighted in gray are only available in black.

black white red yellow green purple blue gray brown clearColors:

D

W

d

Chemicalelement

Test method(mm)

Result(mg/kg)

Cd EN1122:2001 Method B ≤ 5Pb EPA 3050 B ≤ 90

Cr6+ EPA 3050 B ≤ 5Hg EPA 3052 ≤ 5F EN 14582 Method B ≤ 200Cl EN 14582 Method B ≤ 800Br EN 14582 Method B ≤ 800I EN 14582 Method B ≤ 200

REF

Internal Øexpanded (D)

Internal Ø after max.

recovery (d)(mm)

Wall thicknessafter máx.

recovery (W)(mm)

Equivalentrange Ø (mm) Width of the

flattened tube(mm)

ExpandedPerímeter

(mm)M / Spool

(mm) (pol) Mín. Máx

W1,0 1 3/64 0,65 0,28 0,72 1,2 2,36 4,71 200W1,5 1,5 1/16 0,85 0,32 0,94 1,6 3,14 6,28 200W2 2 3/32 1 0,35 1,1 2 3,93 7,85 200

W2,5 2,5 3/32 1,3 0,38 1,43 2,4 4,71 9,42 200W3,0 3 1/8 1,5 0,4 1,65 2,8 5,5 10,99 200W3,5 3,5 1,8 0,42 1,98 3,2 6,28 12,56 200W4 4 2 0,45 2,2 3,6 7,07 14,13 200

W4,5 * 4,5 3/16 2,3 0,5 2,53 4 7,85 15,7 100W5 5 3/16 2,5 0,55 2,75 4,4 8,64 17,27 100W6 6 1/4 3 0,55 3,3 5,2 10,21 20,41 100W7 7 1/4 3,5 0,55 3,85 6 11,78 23,55 100W8 8 5/16 4 0,6 4,4 6,8 13,35 26,69 100W9 9 4,5 0,6 4,95 7,6 14,92 29,83 100

W10 10 3/8 5 0,6 5,5 8,4 16,49 32,97 100W13 13 1/2 6,5 0,65 7,15 10,8 21,21 42,39 100W16 16 5/8 8 0,7 8,8 13,6 26,7 53,38 100W17 17 5/8 8,5 0,7 9,35 14,4 28,26 56,52 100W18 18 3/4 9 0,8 9,9 15,2 29,84 59,66 100W20 20 3/4 10 0,8 11 17,6 34,56 69,08 100W22 22 11 0,8 12,1 19,2 37,7 75,36 100W25 25 1 12,5 0,9 13,75 20,8 40,84 81,64 50W28 28 14 0,9 15,4 23,2 45,55 91,06 50W30 30 15 0,95 16,5 25,2 49,48 98,91 50W35 35 1-1/4 17,5 1 19,25 29,2 57,33 114,61 50W40 40 1-1/2 20 1 22 33,2 65,19 130,31 50W45 45 22,5 1 24,75 36,8 72,25 144,44 25W50 50 2 25 1 27,5 40,8 80,11 160,14 25W60 60 30 1,3 34,1 48 94,25 188,4 25W70 70 36 1,3 39,6 56 109,95 219,8 25W80 80 3 40 1,46 45,1 64 125,66 251,2 25W90 90 46 1,46 50,6 72 141,37 282,6 25

W100 100 4 51 1,46 56,1 80 157,08 314 25W120 120 5 60 1,56 67,1 96 188,49 376,8 25W150 150 75 1,56 83,6 120 235,61 471 25W180 180 90 1,56 100,1 144 282,74 565,2 25

Property Testmethod Result

Physical

Tensile strenght (Mpa)ASTM D2671

≥ 10,4Elongation ≥ 200

Tensile strenghtafter aging (Mpa)

UL 224158ºC X 168 hrs ≥ 7,3

Elongation afteraging (%)

UL 224158ºC X 168 hrs ≥ 100

Thermal shock - heat UL 224250ºC X 4 hrs

NO drippingNO cracking

Eletrical

Thermal shock - coldest UL 224-30ºC X 1 hr NO cracking

Dieletric voltage (kV/mm) IEC 243 ≥ 15Dielectric strenght

300 VUL 224

Not changed to 1500 V600 V Not changed to 2500 V

Volume resistivity(Ω.cm) IEC 93 ≥ 1 X 1014

ChemicalCopper corrosion UL 224

158ºC / 168 hrsPass

Cooper stability PassFlammability UL 224 VW - 1

Shrink Tubes with low voltage (1 kV)Adhesive - Shrink 3:1

The adhesive shrink tubes are semi-flexible and contains internal coating of thermoplasticadhesive, providing complete protection against moisture. Are indicated for use in cable ends, wire taps, connectors, splices of electric and telephone wires, among other applications.

• Use temperature = -45 ºC a 125 ºC• Shrink Temperature = starts at 70 °C and ends at 120 °C• Material = flexible polyolefin with internal adhesive “hot melt”• Longitudinal shrinkage = of less than 8%• Waterproof• Supplied in coils• Adhesive melting temperature 70°C to 90°C

See available colors.

D

W

d

Chemicalelement

Test method(mm)

Result(mg/kg)

Cd EN1122:2001 Method B ≤ 5Pb EPA 3050 B ≤ 90

Cr6+ EPA 3050 B ≤ 5Hg EPA 3052 ≤ 5F EN 14582 Method B ≤ 200Cl EN 14582 Method B ≤ 800Br EN 14582 Method B ≤ 800I EN 14582 Method B ≤ 200

TUBEProperty Test method Result

Tensile strenght (Mpa) ASTM D2671 ≥ 12Elongation (%) ASTM D2671 ≥ 300Tensile strenght

after aging (Mpa) UL 224 158ºC X 168 hrs ≥ 7,3

Elongation after aging (%) UL 224 158ºC X 168 hrs ≥ 200

Dieletric voltage (kV/mm) IEC 243 ≥ 15Volume resistivity

(Ω.cm) IEC 93 ≥ 1 X 1014

ADHESIVEProperty Test method Result

Water absorption ASTM D570 ≤ 0,2%Softening point ASTM E28 95ºC

REF

Internal Øexpanded (D)

Internal Ø after max.

recovery (d)(mm)

Wall thicknessafter máx. recovery

(W)*(mm)

Equivalentrange Ø (mm)

width of theflattenedtube (L)

(mm)

ExpandedPerímeter

(P)(mm)

M / Spool(mm) (pol) Mín. Máx

WA1/8 3,2 1/8 1 0,95 1,1 2,56 5,03 10,05 200WA 3/16 4,8 3/16 1,6 1,1 1,76 3,84 7,54 15,07 100WA1/4 6,4 1/4 2,2 1,2 2,42 5,12 10,05 20,1 100

WA5/16 7,9 5/16 2,7 1,35 2,97 6,32 12,41 24,81 100WA3/8 9,5 3/8 3,2 1,45 3,52 7,6 14,92 29,83 50WA1/2 12,7 1/2 4,2 1,7 4,62 10,16 19,95 39,88 25WA5/8 15 5/8 5,2 1,8 5,72 12 23,56 47,1 25WA3/4 19,1 3/4 6,3 2 6,94 15,28 30 59,97 25WA1 25,4 1 8,5 2,1 9,36 20,32 39,9 79,76 25

WA1-1/4 30 1-1/4 10,2 2,2 11,23 24 47,12 94,20 25WA1-1/2 40 1-1/2 13,5 2,4 14,86 32 62,83 125,6 25

WA2 50 2 17 2,8 14,85 32 78,5 157 25

Page 24: Products Catalog - FRONTEC

46 47

Heat Shrinkables

Shrinkers hoodThe Shrink hoods are given for the closure and isolation of power and communication in the cable ends, preventing chemical corrosion, moisture and dirt.

• Material = flexible polyolefin with internal adhesive“hot melt”• Color = black• Shrink rate = 2:1• Use temperature = -55 ºC to 100 ºC• Dielectric strength = ≥ 20 kV / mm• Longitudinal shrinkage = ≤ 10%• Water absorption ≤ 0,1%• Volumetric resistivity ≥1 x 1014Ω.cm

Shrink Tubes with low voltage (1 kV)Green-yellow- Shrink 2:1

• Meets RoHS standard• Material = flexible polyolefin• Use temperature = -55 ºC a 125 ºC• Shrink Temperature = starts at 70 °C and ends at 120 °C• Flammability = UL VW-1• Longitudinal shrinkage of less than 8%

Property Test method ResultTensile strenght (Mpa) ASTM D2671 ≥ 10,4

Elongation (%) ASTM D2671 ≥ 200Tensile strenght

after aging (Mpa) UL 224 158ºC X 168 hrs ≥ 7,3

Elongation afteraging (%) UL 224 158ºC X 168 hrs ≥ 100

Thermal shock - heat UL 224 250ºC X 4 hrs NO drippingNO cracking

Dieletric voltage (kV/mm) IEC 243 ≥ 15Volume resistivity

(Ω.cm) IEC 93 ≥ 1 X 1014

Flammability UL 224 VW-1

REFInternal Ø

expanded (D)(mm)

Internal Ø aftermax. recovery

(mm)

Length(C)

(mm)

Wall thicknessafter máx. recovery

(W)(mm)

Equivalentrange Ø (mm) Expanded

Perímeter(mm)Mín. Máx

WC 11/5 11 5,5 22 1,1 6,05 8,8 34,54

WC 16/7 16 7,5 75 2,2 8,26 12,8 50,24

WC 25/10 25 10,5 80 2,3 11,56 20 78,5

WC 32/16 32 16,5 90 2,5 18,16 25,6 100,48

WC 50/26 50 26 115 3,4 28,62 40 157

WC 70/37 70 37 120 2,5 40,73 56 219,8

WC 100/46 100 46 140 3,5 50,64 80 314

WC 120/57 120 57 155 3,5 62,75 96 376,8

REF

Ø interno expandido

Internal Ø after max.

recovery (d)(mm)

Wall thicknessafter máx. recovery

(W)(mm)

Equivalentrange Ø (mm) width of the

flattenedtube (mm)

ExpandedPerímeter

(mm)M / Spool

(mm) (pol) Mín. Máx

W1,5VA 1,5 1/16 0,85 0,32 0,94 1,6 3,14 6,28 200

W2,5VA 2,5 3/32 1,3 0,38 1,43 2,4 4,71 9,42 200

W3VA 3 1/8 1,5 0,4 1,65 2,8 5,5 10,99 200

W4,5VA 4,5 3/16 2,3 0,5 2,53 4 7,85 15,7 100

W6VA 6 1/4 3 0,55 3,3 5,2 10,21 20,41 100

W8VA 8 5/16 4 0,6 4,4 6,8 13,35 26,69 100

W10VA 10 3/8 5 0,6 5,5 8,4 16,49 32,97 100

W13VA 13 1/2 6,5 0,65 7,15 10,8 21,21 42,39 100

W18VA 18 3/4 9 0,8 9,9 15,2 29,84 59,66 100

W20VA 20 3/4 10 0,8 11 17,6 34,56 69,08 100

W25VA 25 1 12,5 0,9 13,75 20,8 40,84 81,64 50

W30VA 30 1-1/4 15 0,95 16,5 25,2 49,48 98,91 50

W40VA 40 1-1/2 20 1 22 33,2 65,19 130,31 50

W50VA 50 2 25 1 27,5 40,8 80,11 160,14 25

W80VA 80 3 40 1,46 45,1 64 125,66 251,2 25

W100VA 100 4 51 1,46 56,1 80 157,08 314 25

DW

C

Shrink tubes for medium voltage• Tracking high resistance• Material = flexible polyolefin• Use temperature = -55 ºC to 125 ºC• Shrink Temperature = starts at 90 °C• Provided in black and red

Property ResultTension (A.C.) Insulation up 42 kVPeak voltage 75 kV

TDieletric voltage (kV/mm) ≥ 25Volume resistivity

(Ω.cm) ≥ 4,3 X 1014

REF(10 kV)

Internal Øexpanded (D)

Internal Ø after max.

recovery (d)(mm)

Wall thicknessafter máx. recovery

(W)(mm)

Equivalentrange Ø (mm) Width of the

flattenedtube (mm)

ExpandedPerímeter

(mm)M / Spool

(mm) (pol) Mín. Máx

WB-20-10kV 20 3/4 9 2 9,91 16 31,4 62,8 25

WB-30-10kV 30 13 2 14,31 24 49,48 94,2 25

WB-50-10kV 50 2 20 2,5 22,02 40 80,11 157 25

WB-80-10kV 80 3 32 3 35,23 64 125,66 251,2 25

WB-100-10kV 100 4 40 3 44,03 80 157,08 314 25

WB-120-10kV 120 5 48 3 52,84 96 188,49 376,8 25

WB-180-10kV 180 70 3 77,06 144 282,74 565,2 25

DWd

Page 25: Products Catalog - FRONTEC

48 49

Heat Shrinkables

Shrink for busbars with a thicknessof 1/8 inch

Measure of busbar Perimeter EquivalentDiameter

Equivalent Φranger (mm) Tubes

options (codes)

Diameter (D)mm

Inch (mm) Summingthe sides (mm)

Perimeter÷ 3,14 (π) Mín. Máx Normal Shrinkable

1/8” X

1/4" 3,17 X 6,35 19,04 6,06 4,4 6,8 W8 8,5 4

4,95 7,6 W9 9,5 4,55,5 8,4 W10 10,5 5

3/8" 3,17 X 9,52 25,38 8,08 5,5 8,4 W10 10,5 5

7,15 10,8 W13 13,5 6,5

1/2" 3,17 X 12,7 31,74 10,11 8,8 13,6 W16 16,5 89,9 15,2 W18 19 9

5/8" 3,17 X 15,87 38,08 12,13 8,8 13,6 W16 16,5 89,9 15,2 W18 19 911 17,6 W20 21 10

3/4" 3,17 X 19,05 44,44 14,15

9,9 15,2 W18 19 911 17,6 W20 21 10

12,1 19,2 W22 23 1113,75 20,8 W25 26 12,5

7/8" 3,17 X 22,22 50,78 16,17

11 17,6 W20 21 1012,1 19,2 W22 23 11

13,75 20,8 W25 26 12,515,4 23,2 W28 29 14

1" 3,17 X 25,4 57,14 18,20

12,1 19,2 W22 23 1113,75 20,8 W25 26 12,515,4 23,2 W28 29 1416,5 25,2 W30 31,5 15

1.1/4" 3,17 X 31,75 69,84 22,24 16,5 25,2 W30 31,5 15

19,25 29,2 W35 36,5 17,5

1.1/2" 3,17 X 38,1 82,54 26,29 19,25 29,2 W35 36,5 17,5

22 33,2 W40 41,5 2024,75 36,8 W45 46,5 22,5

1.3/4" 3,17 X 44,45 95,24 30,33 22 33,2 W40 41,5 20

24,75 36,8 W45 46,5 22,527,5 40,8 W50 ≥ 50 25

2" 3,17 X 50,8 107,94 34,38 24,75 36,8 W45 46,5 22,527,5 40,8 W50 ≥ 50 25

2.1/4" 3,17 X 57,15 120,64 38,42 27,5 40,8 W50 ≥ 50 2534,1 48 W60 ≥ 60 31

2.1/2" 3,17 X 63,5 133,34 42,46 34,1 48 W60 ≥ 60 3139,6 56 W70 ≥ 70 36

2.3/4" 3,17 X 69,85 146,04 46,51 34,1 48 W60 ≥ 60 3139,6 56 W70 ≥ 70 36

3" 3,17 X 76,2 158,74 50,55 39,6 56 W70 ≥ 70 3645,1 64 W80 ≥ 80 41

3.1/4" 3,17 X 82,55 171,44 54,60 39,6 56 W70 ≥ 70 3645,1 64 W80 ≥ 80 4150,6 72 W90 ≥ 90 46

3.1/2" 3,17 X 88,9 184,14 58,64 45,1 64 W80 ≥ 80 4150,6 72 W90 ≥ 90 4656,1 80 W100 ≥ 100 51

3.3/4" 3,17 X 92,25 196,84 62,69 45,1 64 W80 ≥ 80 4150,6 72 W90 ≥ 90 4656,1 80 W100 ≥ 100 51

4" 3,17 X 101,6 209,54 66,73 50,6 72 W90 ≥ 90 4656,1 80 W100 ≥ 100 51

4.1/2" 3,17 X 114,3 234,94 74,82 56,1 80 W100 ≥ 100 5167,1 96 W120 ≥ 120 60

5" 3,17 X 127 260,34 82,91 67,1 96 W120 ≥ 120 60

5.1/2" 3,17 X 139,7 285,74 91,00 67,1 96 W120 ≥ 120 6083,6 120 W150 ≥ 150 75

6" 3,17 X 152,4 311,14 99,09 83,6 120 W150 ≥ 150 75

The highlighted items are the most used.

Shrink tubes for high voltage• Tracking high resistance• Material = flexible polyolefin• Use temperature = -55 ºC to 125 ºC

• Shrink Temperature = starts at 90 °C• Provided in black and red

Heat blowersThe heat blowers assist in carrying out various tasks in which heat is required, as in thecase of shrink use.

HL 1800 HL 1500 HL 2100

REF(35 kV)

Internal Øexpanded (D)

Internal Ø after max.

recovery (d)(mm)

Wall thicknessafter máx. recovery

(W)(mm)

Equivalentrange Ø (mm) Width of the

flattenedtube (mm)

ExpandedPerímeter

(mm)M / Spool

(mm) (pol) Mín. Máx

WB-20-35kV 20 3/4 9 4 9,91 16 31,4 62,8 15

WB-30-35kV 30 13 4 14,31 24 49,48 94,2 15

WB-50-35kV 50 2 20 4,5 22,02 40 80,11 157 15

WB-80-35kV 80 3 32 4,5 35,23 64 125,66 251,2 15

WB-100-35kV 100 4 40 4,5 44,03 80 157,08 314 15

WB-120-35kV 120 5 48 5 52,84 96 188,49 376,8 15

WB-180-35kV 180 70 5,5 77,06 144 282,74 565,2 15

REFPotency

Temperature (ºC) Temperature Control Weight (Kg)110V 220V

HL1800 1500 1800 100 a 600 Continuous (back wheel) 0,65

HL1500 1400 1400 300 a 500 E1 e E2 (switch) 0,7

HL2100 1500 2000 100 a 600 Digital (buttons “+” e “-”) 0,7

Page 26: Products Catalog - FRONTEC

50 51

Heat Shrinkables

Measure of busbar Perimeter EquivalentDiameter

Equivalent Φranger (mm) Tubes

options (codes)

Diameter (D)mm

Inch (mm) Summingthe sides (mm)

Perimeter÷ 3,14 (π) Mín. Máx Normal Shrinkable

1/4” X

1/4" 6,35 X 6,35 25,4 8,09 5,5 8,4 W10 10,5 5

7,15 10,8 W13 13,5 6,5

3/8" 6,35 X 9,52 31,74 10,11 8,8 13,6 W16 16,5 89,9 15,2 W18 19 9

1/2" 6,35 X 12,7 38,1 12,13 8,8 13,6 W16 16,5 89,9 15,2 W18 19 911 17,6 W20 21 10

5/8" 6,35 X 15,87 44,44 14,15

9,9 15,2 W18 19 911 17,6 W20 21 10

12,1 19,2 W22 23 1113,75 20,8 W25 26 12,5

3/4" 6,35 X 19,05 50,78 16,17

11 17,6 W20 21 1012,1 19,2 W22 23 11

13,75 20,8 W25 26 12,515,4 23,2 W28 29 14

7/8" 6,35 X 22,22 57,14 18,20

12,1 19,2 W22 23 1112,1 19,2 W22 23 11

13,75 20,8 W25 26 12,515,4 23,2 W28 29 14

1" 6,35 X 25,4 63,5 20,22 15,4 23,2 W28 29 1416,5 25,2 W30 31,5 15

1.1/4" 6,35 X 31,75 76,2 24,27 16,5 25,2 W30 31,5 15

19,25 29,2 W35 36,5 17,5

1.1/2" 6,35 X 38,1 88,9 28,31

19,25 29,2 W35 36,5 17,522 33,2 W40 41,5 20

27,5 40,8 W50 ≥ 50 2524,75 36,8 W45 46,5 22,5

1.3/4" 6,35 X 44,45 101,6 32,36 24,75 36,8 W45 46,5 22,527,5 40,8 W50 ≥ 50 25

2" 6,35 X 50,8 114,3 36,40 27,5 40,8 W50 ≥ 50 2534,1 48 W60 ≥ 60 31

2.1/4" 6,35 X 57,15 127 40,45 34,1 48 W60 ≥ 60 3139,6 56 W70 ≥ 70 36

2.1/2" 6,35 X 63,5 139,7 44,49 34,1 48 W60 ≥ 60 3139,6 56 W70 ≥ 70 36

2.3/4" 6,35 X 69,85 152,4 48,54 39,6 56 W70 ≥ 70 3645,1 64 W80 ≥ 80 41

3" 6,35 X 76,2 165,1 52,58 39,6 56 W70 ≥ 70 3645,1 64 W80 ≥ 80 4150,6 72 W90 ≥ 90 46

3.1/4" 6,35 X 82,55 177,8 56,62 45,1 64 W80 ≥ 80 4150,6 72 W90 ≥ 90 4656,1 80 W100 ≥ 100 51

3.1/2" 6,35 X 88,9 190,5 60,67 45,1 64 W80 ≥ 80 4150,6 72 W90 ≥ 90 4656,1 80 W100 ≥ 100 51

3.3/4" 6,35 X 95,25 203,2 64,71 50,6 72 W90 ≥ 90 4656,1 80 W100 ≥ 100 51

4" 6,35 X 101,6 215,9 68,76 50,6 72 W90 ≥ 90 4656,1 80 W100 ≥ 100 51

4.1/2" 6,35 X 114,3 241,3 76,85 56,1 80 W100 ≥ 100 5167,1 96 W120 ≥ 120 60

5" 6,35 X 127 266,7 84,94 67,1 96 W120 ≥ 120 60

5.1/2" 6,35 X 139,7 292,1 93,03 67,1 96 W120 ≥ 120 6083,6 120 W150 ≥ 150 75

6" 6,35 X 152,4 317,5 101,11 83,6 120 W150 ≥ 150 75

Shrink for busbars with a thicknessof 1/4 inch

The highlighted items are the most used.

Shrink for busbars with a thicknessof 3/16 inch

Measure of busbar Perimeter EquivalentDiameter

Equivalent Φranger (mm) Tubes

options (codes)

Diameter (D)mm

Inch (mm) Summingthe sides (mm)

Perimeter÷ 3,14 (π) Mín. Máx Normal Shrinkable

3/16” X

1/4" 4,76 X 6,35 22,22 7,08 4,4 6,8 W8 8,5 4

4,95 7,6 W9 9,5 4,55,5 8,4 W10 10,5 5

3/8" 4,76 X 9,52 28,56 9,10 5,5 8,4 W10 10,5 5

7,15 10,8 W13 13,5 6,5

1/2" 4,76 X 12,7 34,92 11,12 8,8 13,6 W16 16,5 89,9 15,2 W18 19 9

5/8" 4,76 X 15,87 41,26 13,14 9,9 15,2 W18 19 911 17,6 W20 21 10

12,1 19,2 W22 23 11

3/4" 4,76 X 19,05 47,62 15,17 11 17,6 W20 21 10

12,1 19,2 W22 23 1113,75 20,8 W25 26 12,5

7/8" 4,76 X 22,22 53,96 17,18 12,1 19,2 W22 23 11

13,75 20,8 W25 26 12,515,4 23,2 W28 29 14

1" 4,76 X 25,4 60,32 19,21 15,4 23,2 W28 29 1416,5 25,2 W30 31,5 15

1.1/4" 4,76 X 31,75 73,02 23,25 16,5 25,2 W30 31,5 15

19,25 29,2 W35 36,5 17,5

1.1/2" 4,76 X 38,1 85,72 27,30 19,25 29,2 W35 36,5 17,5

22 33,2 W40 41,5 2024,75 36,8 W45 46,5 22,5

1.3/4" 4,76 X 44,45 98,42 31,34 22 33,2 W40 41,5 20

24,75 36,8 W45 46,5 22,527,5 40,8 W50 ≥ 50 25

2" 4,76 X 50,8 111,12 35,39 27,5 40,8 W50 ≥ 50 2534,1 48 W60 ≥ 60 31

2.1/4" 4,76 X 57,15 123,82 39,43 34,1 48 W60 ≥ 60 3139,6 56 W70 ≥ 70 36

2.1/2" 4,76 X 63,5 136,52 43,48 34,1 48 W60 ≥ 60 3139,6 56 W70 ≥ 70 36

2.3/4" 4,76 X 69,85 149,22 47,52 39,6 56 W70 ≥ 70 3645,1 64 W80 ≥ 80 41

3" 4,76 X 76,2 161,92 51,57 39,6 56 W70 ≥ 70 3645,1 64 W80 ≥ 80 4150,6 72 W90 ≥ 90 46

3.1/4" 4,76 X 82,55 174,62 55,61 45,1 64 W80 ≥ 80 4150,6 72 W90 ≥ 90 4656,1 80 W100 ≥ 100 51

3.1/2" 4,76 X 88,9 187,32 59,66 45,1 64 W80 ≥ 80 4150,6 72 W90 ≥ 90 4656,1 80 W100 ≥ 100 51

3.3/4" 4,76 X 95,25 200,02 63,70 50,6 72 W90 ≥ 90 4656,1 80 W100 ≥ 100 51

4" 4,76 X 101,6 212,72 67,75 50,6 72 W90 ≥ 90 4656,1 80 W100 ≥ 100 51

4.1/2" 4,76 X 114,3 238,12 75,83 56,1 80 W100 ≥ 100 5167,1 96 W120 ≥ 120 60

5" 4,76 X 127 263,52 83,92 67,1 96 W120 ≥ 120 60

5.1/2" 4,76 X 139,7 288,92 92,01 67,1 96 W120 ≥ 120 6083,6 120 W150 ≥ 150 75

6" 4,76 X 152,4 314,32 100,10 83,6 120 W150 ≥ 150 75

The highlighted items are the most used.

Page 27: Products Catalog - FRONTEC

52 53

Heat Shrinkables

Measure of busbar Perimeter EquivalentDiameter

Equivalent Φranger (mm) Tubes

options (codes)

Diameter (D)mm

Inch (mm) Summingthe sides (mm)

Perimeter÷ 3,14 (π) Mín. Máx Normal Shrinkable

3/8” X

1/4" 9,52 X 6,35 31,74 10,11 8,8 13,6 W16 16,5 89,9 15,2 W18 19 9

3/8" 9,52 X 9,52 38,08 12,13 8,8 13,6 W16 16,5 89,9 15,2 W18 19 911 17,6 W20 21 10

1/2" 9,52 X 12,7 44,44 14,15

9,9 15,2 W18 19 911 17,6 W20 21 10

12,1 19,2 W22 23 1113,75 20,8 W25 26 12,5

5/8" 9,52 X 15,87 50,78 16,17

11 17,6 W20 21 1012,1 19,2 W22 23 11

13,75 20,8 W25 26 12,515,4 23,2 W28 29 14

3/4" 9,52 X 19,05 57,14 18,20

12,1 19,2 W22 23 1113,75 20,8 W25 26 12,515,4 23,2 W28 29 1416,5 25,2 W30 31,5 15

7/8" 9,52 X 22,22 63,48 20,22 15,4 23,2 W28 29 1416,5 25,2 W30 31,5 15

1" 9,52 X 25,4 69,84 22,24 16,5 25,2 W30 31,5 15

19,25 29,2 W35 36,5 17,5

1.1/4" 9,52 X 31,75 82,54 26,29 19,25 29,2 W35 36,5 17,5

22 33,2 W40 41,5 2024,75 36,8 W45 46,5 22,5

1.1/2" 9,52 X 38,1 95,24 30,33 22 33,2 W40 41,5 20

24,75 36,8 W45 46,5 22,527,5 40,8 W50 ≥ 50 25

1.3/4" 9,52 X 44,45 107,94 34,38 24,75 36,8 W45 46,5 22,527,5 40,8 W50 ≥ 50 25

2" 9,52 X 50,8 120,64 38,42 27,5 40,8 W50 ≥ 50 2534,1 48 W60 ≥ 60 31

2.1/4" 9,52 X 57,15 133,34 42,46 34,1 48 W60 ≥ 60 3139,6 56 W70 ≥ 70 36

2.1/2" 9,52 X 63,5 146,04 46,51 34,1 48 W60 ≥ 60 3139,6 56 W70 ≥ 70 36

2.3/4" 9,52 X 69,85 158,74 50,55 39,6 56 W70 ≥ 70 3645,1 64 W80 ≥ 80 41

3" 9,52 X 76,2 171,44 54,60 39,6 56 W70 ≥ 70 3645,1 64 W80 ≥ 80 4150,6 72 W90 ≥ 90 46

3.1/4" 9,52 X 82,55 184,14 58,64 45,1 64 W80 ≥ 80 4150,6 72 W90 ≥ 90 4656,1 80 W100 ≥ 100 51

3.1/2" 9,52 X 88,9 196,84 62,69 45,1 64 W80 ≥ 80 4150,6 72 W90 ≥ 90 4656,1 80 W100 ≥ 100 51

3.3/4" 9,52 X 95,52 209,54 66,73 50,6 72 W90 ≥ 90 4656,1 80 W100 ≥ 100 51

4" 9,52 X 101,6 222,24 70,78 56,1 80 W100 ≥ 100 5167,1 96 W120 ≥ 120 60

4.1/2" 9,52 X 114,3 247,64 78,87 56,1 80 W100 ≥ 100 5167,1 96 W120 ≥ 120 60

5" 9,52 X 127 273,04 86,96 67,1 96 W120 ≥ 120 605.1/2" 9,52 X 139,7 298,44 95,04 83,6 120 W150 ≥ 150 75

6" 9,52 X 152,4 323,84 103,13 83,6 120 W150 ≥ 150 75

Shrink for busbars with a thicknessof 3/8 inch

The highlighted items are the most used.

Measure of busbar Perimeter EquivalentDiameter

Equivalent Φranger (mm) Tubes

options (codes)

Diameter (D)mm

Inch (mm) Summingthe sides (mm)

Perimeter÷ 3,14 (π) Mín. Máx Normal Shrinkable

5/16” X

1/4" 7,93 X 6,35 28,56 9,10 5,5 8,4 W10 10,5 5

7,15 10,8 W13 13,5 6,5

3/8" 7,93 X 9,52 34,9 11,11 8,8 13,6 W16 16,5 8

9,9 15,2 W18 19 9

1/2" 7,93 X 12,7 41,26 13,14

9,9 15,2 W18 19 9

11 17,6 W20 21 10

12,1 19,2 W22 23 11

5/8" 7,93 X 15,87 47,6 15,16

11 17,6 W20 21 10

12,1 19,2 W22 23 11

13,75 20,8 W25 26 12,5

3/4" 7,93 X 19,05 53,96 17,18

12,1 19,2 W22 23 11

13,75 20,8 W25 26 12,5

15,4 23,2 W28 29 14

7/8" 7,93 X 22,22 60,32 19,21 15,4 23,2 W28 29 14

16,5 25,2 W30 31,5 15

1" 7,93 X 25,4 66,66 21,23 16,5 25,2 W30 31,5 15

19,25 29,2 W35 36,5 17,5

1.1/4" 7,93 X 31,75 79,36 25,27

16,5 25,2 W30 31,5 15

19,25 29,2 W35 36,5 17,5

22 33,2 W40 41,5 20

1.1/2" 7,93 X 38,1 92,06 29,32

22 33,2 W40 41,5 20

24,75 36,8 W45 46,5 22,5

27,5 40,8 W50 ≥ 50 25

1.3/4" 7,93 X 44,45 104,76 33,36 24,75 36,8 W45 46,5 22,5

27,5 40,8 W50 ≥ 50 25

2" 7,93 X 50,8 117,46 37,41 27,5 40,8 W50 ≥ 50 25

34,1 48 W60 ≥ 60 31

2.1/4" 7,93 X 57,15 130,16 41,45 34,1 48 W60 ≥ 60 31

39,6 56 W70 ≥ 70 36

2.1/2" 7,93 X 63,5 142,86 45,50 34,1 48 W60 ≥ 60 31

39,6 56 W70 ≥ 70 36

2.3/4" 7,93 X 69,85 155,56 49,54 39,6 56 W70 ≥ 70 36

45,1 64 W80 ≥ 80 41

3" 7,93 X 76,2 168,26 53,59

39,6 56 W70 ≥ 70 36

45,1 64 W80 ≥ 80 41

50,6 72 W90 ≥ 90 46

3.1/4" 7,93 X 82,55 180,96 57,63

45,1 64 W80 ≥ 80 41

50,6 72 W90 ≥ 90 46

56,1 80 W100 ≥ 100 51

3.1/2" 7,93 X 88,9 193,66 61,68

45,1 64 W80 ≥ 80 41

50,6 72 W90 ≥ 90 46

56,1 80 W100 ≥ 100 51

3.3/4" 7,93 X 95,25 206,36 65,72 50,6 72 W90 ≥ 90 46

56,1 80 W100 ≥ 100 51

4" 7,93 X 101,6 219,06 69,76 50,6 72 W90 ≥ 90 46

56,1 80 W100 ≥ 100 51

4.1/2" 7,93 X 114,3 244,46 77,85 56,1 80 W100 ≥ 100 51

67,1 96 W120 ≥ 120 60

5" 7,93 X 127 269,86 85,94 67,1 96 W120 ≥ 120 60

5.1/2" 7,93 X 139,7 295,26 94,03 67,1 96 W120 ≥ 120 60

83,6 120 W150 ≥ 150 75

6" 7,93 X 152,4 320,66 102,12 83,6 120 W150 ≥ 150 75

Shrink for busbars with a thicknessof 5/16 inch

The highlighted items are the most used.

Page 28: Products Catalog - FRONTEC

54 55

Heat Shrinkables

Measure of busbar Perimeter EquivalentDiameter

Equivalent Φranger (mm) Tubes

options (codes)

Diameter (D)mm

Inch (mm) Summingthe sides (mm)

Perimeter÷ 3,14 (π) Mín. Máx Normal Shrinkable

1/2” X

1/4" 12,7 X 6,35 38,1 12,13 8,8 13,6 W16 16,5 89,9 15,2 W18 19 911 17,6 W20 21 10

3/8" 12,7 X 9,52 44,44 14,15

9,9 15,2 W18 19 911 17,6 W20 21 10

12,1 19,2 W22 23 1113,75 20,8 W25 26 12,5

1/2" 12,7 X 12,7 50,78 16,17

11 17,6 W20 21 1012,1 19,2 W22 23 11

13,75 20,8 W25 26 12,515,4 23,2 W28 29 14

5/8" 12,7 X 15,87 57,14 18,20

12,1 19,2 W22 23 1113,75 20,8 W25 26 12,515,4 23,2 W28 29 1416,5 25,2 W30 31,5 15

3/4" 12,7 X 19,05 63,5 20,22 15,4 23,2 W28 29 1416,5 25,2 W30 31,5 15

7/8" 12,7 X 22,22 69,84 22,24 16,5 25,2 W30 31,5 15

19,25 29,2 W35 36,5 17,519,25 29,2 W35 36,5 17,5

1" 12,7 X 25,4 76,2 24,27 16,5 25,2 W30 31,5 15

19,25 29,2 W35 36,5 17,5

1.1/4" 12,7 X 31,75 88,9 28,31

19,25 29,2 W35 36,5 17,522 33,2 W40 41,5 20

24,75 36,8 W45 46,5 22,527,5 40,8 W50 ≥ 50 25

1.1/2" 12,7 X 38,1 101,6 32,36 24,75 36,8 W45 46,5 22,527,5 40,8 W50 ≥ 50 25

1.3/4" 12,7 X 44,45 114,3 36,40 27,5 40,8 W50 ≥ 50 2534,1 48 W60 ≥ 60 31

2" 12,7 X 50,8 127 40,45 34,1 48 W60 ≥ 60 3139,6 56 W70 ≥ 70 36

2.1/4" 12,7 X 57,15 139,7 44,49 34,1 48 W60 ≥ 60 3139,6 56 W70 ≥ 70 36

2.1/2" 12,7 X 63,5 152,4 48,54 39,6 56 W70 ≥ 70 3645,1 64 W80 ≥ 80 41

2.3/4" 12,7 X 69,85 165,1 52,58 39,6 56 W70 ≥ 70 3645,1 64 W80 ≥ 80 4150,6 72 W90 ≥ 90 46

3" 12,7 X 76,2 177,8 56,62 45,1 64 W80 ≥ 80 4150,6 72 W90 ≥ 90 46

3.1/4" 12,7 X 82,55 190,5 60,67 45,1 64 W80 ≥ 80 4150,6 72 W90 ≥ 90 4656,1 80 W100 ≥ 100 51

3.1/2" 12,7 X 88,9 203,2 64,71 50,6 72 W90 ≥ 90 4656,1 80 W100 ≥ 100 51

3.3/4" 12,7 X 95,25 215,9 68,76 56,1 80 W100 ≥ 100 5167,1 96 W120 ≥ 120 60

4" 12,7 X 101,6 228,6 72,80 56,1 80 W100 ≥ 100 5167,1 96 W120 ≥ 120 60

4.1/2" 12,7 X 114,3 254 80,89 67,1 96 W120 ≥ 120 60

5" 12,7 X 127 279,4 88,98 67,1 96 W120 ≥ 120 6083,6 120 W150 ≥ 150 75

5.1/2" 12,7 X 139,7 304,8 97,07 83,6 120 W150 ≥ 150 75

6" 12,7 X 152,4 330,2 105,16 83,6 120 W150 ≥ 150 75

100,1 144 W180 ≥ 180 90

Shrink for busbars with a thicknessof 1/2 inch

The highlighted items are the most used.

Measure of busbar Perimeter EquivalentDiameter

Equivalent Φranger (mm) Tubes

options (codes)

Diameter (D)mm

Inch (mm) Summingthe sides (mm)

Perimeter÷ 3,14 (π) Mín. Máx Normal Shrinkable

5/8” X

1/4" 15,87 X 6,35 44,44 14,15

9,9 15,2 W18 19 911 17,6 W20 21 10

12,1 19,2 W22 23 1113,75 20,8 W25 26 12,5

3/8" 15,87 X 9,52 50,78 16,17

11 17,6 W20 21 1012,1 19,2 W22 23 11

13,75 20,8 W25 26 12,515,4 23,2 W28 29 14

1/2" 15,87 X 12,7 57,14 18,20

12,1 19,2 W22 23 1113,75 20,8 W25 26 12,515,4 23,2 W28 29 1416,5 25,2 W30 31,5 15

5/8" 15,87 X 15,87 63,48 20,22 15,4 23,2 W28 29 1416,5 25,2 W30 31,5 15

3/4" 15,87 X 19,05 69,84 22,24 16,5 25,2 W30 31,5 15

19,25 29,2 W35 36,5 17,5

7/8" 15,87 X 22,22 76,18 24,26 16,5 25,2 W30 31,5 15

19,25 29,2 W35 36,5 17,5

1" 15,87 X 25,4 82,54 26,29 19,25 29,2 W35 36,5 17,5

22 33,2 W40 41,5 2024,75 36,8 W45 46,5 22,5

1.1/4" 15,87 X 31,75 95,24 30,33 22 33,2 W40 41,5 20

24,75 36,8 W45 46,5 22,527,5 40,8 W50 ≥ 50 25

1.1/2" 15,87 X 38,1 107,94 34,38 24,75 36,8 W45 46,5 22,527,5 40,8 W50 ≥ 50 25

1.3/4" 15,87 X 44,45 120,64 38,42 27,5 40,8 W50 ≥ 50 2534,1 48 W60 ≥ 60 31

2" 15,87 X 50,8 133,34 42,46 34,1 48 W60 ≥ 60 3139,6 56 W70 ≥ 70 36

2.1/4" 15,87 X 57,15 146,04 46,51 34,1 48 W60 ≥ 60 3139,6 56 W70 ≥ 70 36

2.1/2" 15,87 X 63,5 158,74 50,55 39,6 56 W70 ≥ 70 3645,1 64 W80 ≥ 80 41

2.3/4" 15,87 X 69,85 171,44 54,60 39,6 56 W70 ≥ 70 3645,1 64 W80 ≥ 80 4150,6 72 W90 ≥ 90 46

3" 15,87 X 76,2 184,14 58,64 45,1 64 W80 ≥ 80 4150,6 72 W90 ≥ 90 4656,1 80 W100 ≥ 100 51

3.1/4" 15,87 X 82,55 196,84 62,69 45,1 64 W80 ≥ 80 4150,6 72 W90 ≥ 90 4656,1 80 W100 ≥ 100 51

3.1/2" 15,87 X 88,9 209,54 66,73 50,6 72 W90 ≥ 90 4656,1 80 W100 ≥ 100 51

3.3/4" 15,87 X 95,25 222,24 70,78 56,1 80 W100 ≥ 100 5167,1 96 W120 ≥ 120 60

4" 15,87 X 101,6 234,94 74,82 56,1 80 W100 ≥ 100 5167,1 96 W120 ≥ 120 60

4.1/2" 15,87 X 114,3 260,34 82,91 67,1 96 W120 ≥ 120 60

5" 15,87 X 127 285,74 91,00 67,1 96 W120 ≥ 120 6083,6 120 W150 ≥ 150 75

5.1/2" 15,87 X 139,7 311,14 99,09 83,6 120 W150 ≥ 150 75

6" 15,87 X 152,4 336,54 107,18 83,6 120 W150 ≥ 150 75

100,1 144 W180 ≥ 180 90

Shrink for busbars with a thicknessof 5/8 inch

The highlighted items are the most used.

Page 29: Products Catalog - FRONTEC

5756

Measure of busbar Perimeter EquivalentDiameter

Equivalent Φranger (mm) Tubes

options (codes)

Diameter (D)mm

Inch (mm) Summingthe sides (mm)

Perimeter÷ 3,14 (π) Mín. Máx Normal Shrinkable

1/16” X

1/4” 1,59 X 6,35 15,88 5,06 3,85 6 W7 7 3,54,4 6,8 W8 8,5 4

4,95 7,6 W9 9,5 4,5

3/8” 1,59 X 9,52 22,22 7,08 4,95 7,6 W9 9,5 4,55,5 8,4 W10 10,5 5

1/2” 1,59 X 12,7 28,58 9,10 7,15 10,8 W13 13 6,58,8 13,6 W16 16,5 8

5/8” 1,59 X 15,87 34,92 11,12 8,8 13,6 W16 16,5 89,9 15,2 W18 19 9

3/4” 1,59 X 19,05 41,28 13,15 9,9 15,2 W18 19 911 17,6 W20 21 10

12,1 19,2 W22 23 11

7/8” 1,59 X 22,22 47,62 15,17 11 17,6 W20 21 10

12,1 19,2 W22 23 1113,75 20,8 W25 26 12,5

1” 1,59 X 25,4 53,98 17,19

12,1 19,2 W22 23 1113,75 20,8 W25 26 12,515,4 23,2 W28 29 1416,5 25,2 W30 31,5 15

1.1/4” 1,59 X 31,75 66,68 21,24 15,4 23,2 W28 29 1416,5 25,2 W30 31,5 15

19,25 29,2 W35 36,5 17,5

1.1/2” 1,59 X 38,1 79,38 25,28 19,25 29,2 W35 36,5 17,5

22 33,2 W40 41,5 2024,75 36,8 W45 46,5 22,5

1.3/4” 1,59 X 44,45 92,08 29,32 22 33,2 W40 41,5 20

24,75 36,8 W45 46,5 22,527,5 40,8 W50 ≥ 50 25

2” 1,59 X 50,8 104,78 33,37 24,75 36,8 W45 46,5 22,527,5 40,8 W50 ≥ 50 25

2.1/4” 1,59 X 57,15 117,48 37,41 27,5 40,8 W50 ≥ 50 2534,1 48 W60 ≥ 60 31

2.1/2” 1,59 X 63,5 130,18 41,46 34,1 48 W60 ≥ 60 3139,6 56 W70 ≥ 70 36

2.3/4” 1,59 X 69,85 142,88 45,50 34,1 48 W60 ≥ 60 3139,6 56 W70 ≥ 70 36

3” 1,59 X 76,2 155,58 49,55 39,6 56 W70 ≥ 70 3645,1 64 W80 ≥ 80 41

3.1/4” 1,59 X 82,55 168,28 53,59 39,6 56 W70 ≥ 70 3645,1 64 W80 ≥ 80 4150,6 72 W90 ≥ 90 46

3.1/2” 1,59 X 88,9 180,98 57,64 45,1 64 W80 ≥ 80 4150,6 72 W90 ≥ 90 4656,1 80 W100 ≥ 100 51

3.3/4” 1,59 X 92,25 187,68 59,77 45,1 64 W80 ≥ 80 4150,6 72 W90 ≥ 90 4656,1 80 W100 ≥ 100 51

4” 1,59 X 101,6 206,38 65,73 50,6 72 W90 ≥ 90 4656,1 80 W100 ≥ 100 51

4.1/2” 1,59 X 114,3 231,78 73,82 56,1 80 W100 ≥ 100 5167,1 96 W120 ≥ 120 60

5” 1,59 X 127 257,18 81,90 67,1 96 W120 ≥ 120 60

5.1/2” 1,59 X 139,7 282,58 89,99 67,1 96 W120 ≥ 120 6083,6 120 W150 ≥ 150 75

6” 1,59 X 152,4 307,98 99,09 83,6 120 W150 ≥ 150 75

Shrink for busbars with a thicknessof 1/16 Inch

The highlighted items are the most used.

Connectorsand Terminals

Page 30: Products Catalog - FRONTEC

58 59

Connectors and Terminals

ConectoresMaterial: PA 66 (Nylon 66)Use temperature: -40°C a 85°CFlammability: UL94 V2

F2009

Connector 1 way forlong male terminal 6.3

F3032

Connector 2 ways withfixation for blade fuse holder

F2014

Connector 1 way forfemale terminal without lock 6.3

F2631

Connector for alternator

F2090

Connector 1 way forterminal flag 6.3

F2619

Connector 3 ways formale terminal 6.3

F2615

Connector 2 ways formale terminal 6.3

F2642

Connector 5 ways withfixative relay

F2011

Connector 1 way forshort male terminal 6.3

F3039

Connector 2 ways for bladefuse holder

F1970

Connector 1 way forfemale terminal 2.8

F2015

Connector 3 ways forvehicule headlight

F2100

Connector 1 way forterminal flag 4.8

F2621

Connector 4 ways forfemale terminal 6.3

F2616

Connector 2 ways in“ T “for female terminal 6.3

F2630

Connector 5 ways for relay

F2013

Connector 1 way forfemale terminal lockable 6.3

F3038

Connector 2 ways for bladefuse holder “MAX”

F2340

Connector 1 way forfemale terminal 4.8

F2618

Connector 3 ways forfemale terminal 6.3

F2614

Connector 2 ways forfemae terminal 6.3

F2622

Connector 4 ways formale terminal 6.3

F2617

Connector 2 ways in “T”for male terminal 6.3

F2625

Connector 6 ways formale terminal 6.3

F1113

F1182

F1113

F1182

F1112

F1184

F1182

F1182

F1182

F1113

F1113

F1182

F1113

F1180 F1186 F1185

F1183 F1108

F1113 F1182

F1182 F1182 F1184

F1182

Page 31: Products Catalog - FRONTEC

60 61

Connectors and Terminals

Kit – Connector with terminals

Fuse holders

Socket

F2623

Connector 6 ways forfemale terminal 6.3

F2626

Connector 8 ways forfemale terminal 6.3

F2627

Connector 8 ways formale terminal 6.3

F2702

Kit connector 2 ways in “T”(male and female) with4 brass terminals

F2705

Kit connector 5 ways with5 terminals (for relay)

F2703

Kit connector 3 ways (male and female) with 6 brass terminals

F2706

Kit connector 6 ways (male and female) with 12 brass terminals

F2704

Kit connector 4 ways (male and female) with 8 brass terminals

F2708

Kit connector 8 ways (male and female) with 16 brass terminals

FM3032

Fuse holder with tabsfor fixing

Cable of 1,5 mm²

FM2015

Vehicle headlamp(cable of 1,5 mm²)

FD3032

Kit fuse holder

(1 connector with tabsand 2 female terminals 6.3)

F3041

Universal for vehicle headlamps 1 pole- cable 1,0 mm²- Nylon 66 socket- Operating temperature: -40ºC a 85ºC

F3040

Universal for vehicle headlamps 2 poles- cable1,0 mm²- Nylon 66 socket- Operating temperature: -40ºC a 85ºC

FM3039

Fuse holder

Cable of 1,5 mm²

FD2015

Kit for vehicle headlamp(1 connector and 3 terminals)

FD3038

Kit fuse holder “MAX”

(1 connector and 2 terminalsflag 6.3)

FM3038

Fuse holder “ MAX”

Cable of 4,0 mm²

FM2018

Veicle headlamp (Lamp H7)

F1182 F1182 F1113

Page 32: Products Catalog - FRONTEC

62 63

Connectors and Terminals

TerminalsMaterial: brassThe terminal images are in the real size.

F1112

Short male 6.3

F1115

Male without lock 2.8

F1182

Female lockable 6.3

F1186

Female without lock 2.8

F1113

Long male 6.3 lockable

F1180

Female without lock 6.3

F1182BG

Female lockable 6.3(big barrel)

F1186CT

Female lockable 2.8

F1114

Male lockable 2.8

F1181

Female lockable 9.7 (big)

F1185

Female lockable 4.8

F1188

Hermaphrodite 6.3

F1183

Flag without lock 6.3

F1102

Eye bolt 3 mm

F1132

Eye bolt 3/16”

F1143

Eye bolt 8 mm

F1184

Flag lockable 7.2(farol de veículos)

F1124

Eye bolt 1/8”

F1133

Eye bolt 3/16”

F1141

Eye bolt ¼”(for cables 2,5 a 6 mm)

F1108

Flag without lock 4.8

F1126

Eye bolt 5/32”

F1142

Eye bolt 6 mm

F1144

Eye bolt ¼”(for cables 1,5 a 4 mm)

Page 33: Products Catalog - FRONTEC

64

Battery Grips

F1178

Eye bolt 8,5 mm

F1135

Fork 3/16”

F1160

Eye bolt 3/8”(thickness 0,6 mm)

F1151

Fork ¼”

F1162

Eye bolt 3/8”(thickness1,0 mm)

F2003

Galvanized steel to 150 A

F2004

Galvanized steel to 100 A

F2005

Galvanized steel withbrass ferrule to 150 A

Page 34: Products Catalog - FRONTEC

51 3201.2477Estrada do Socorro, 380

Arroio da ManteigaSão Leopoldo - RS

93135.390SAC: 0800.7042477

www.frontec.com.br

2015

| 2

a Edi

ção

MADE TO MAKE IT WELL DONE.