Page 1: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

PRODUCT LIST

Page 2: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

SECTION A

ELECTRICITY TRANSMISSION EQUIPMENT

Page 3: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

1) WOODEN TREATED POLES – FENCING AND TRANSMISSION

We are able to supply the market with poles of lengths diameters and sizes. We produce international standard poles

and will treat them with either CCA or Creosote. Its up to you to choose.

CCA

Creosote

Avaibalve Lengths:

1.8m, 2.1m, 2.4m, 2.7m, 3.0m, 3.6m, 4.2m, 4.8m, 5.4m, 6.0m, 6.6m, 7.2m, 9.0m, 10.0m, 11.0m, 12.0m

Available Diameters:

25-50mm

50-75mm

75-100mm

125-150mm

160-180mm

180-200mm

Soecifications Applicable:

SABS

SAZ

Page 4: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

2) STEEL UTILITY POLES

Page 5: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

3) CONCRETE TRANSMISSION POLES

Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry Inspection Box Strength Planting Depth M mm mm t mm mm kN m 4.5 115 183 0.210 150 x 75 465 x 145 2.5 1.00 4.5 130 198 0.237 150 x 75 465 x 145 2.5 1.00 6.0 115 205 0.307 150 x 75 465 x 145 2.5 1.20 6.0 130 220 0.346 150 x 75 465 x 145 2.5 1.20 7.5 115 228 0.419 150 x 75 465 x 145 2.5 1.35 7.5 130 243 0.473 150 x 75 465 x 145 2.5 1.35 8.0 130 250 0.522 150 x 75 465 x 145 2.5 1.40 9.0 130 265 0.617 150 x 75 465 x 145 2.5 or 5.5 1.50 10.0 130 280 0.720 150 x 75 465 x 145 5.5 1.60 11.0 130 295 0.828 150 x 75 465 x 145 5.5 1.70 12.0 130 310 0.967 150 x 75 465 x 145 5.5 1.80 13.0 130 325 1.066 150 x 75 465 x 145 5.5 1.90

Reticulation Length Tip Butt Mass Strength Planting Depth M mm mm kg kN m 7.0 130 235 434 3.5 1.3

Page 6: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

9.0 160 295 646 5.5 1.5 9.0 160 295 807 8.5 1.5 9.0 190 325 950 12.0 1.5 10.0 160 310 866 5.5 1.6 10.0 190 340 1095 12.0 1.6 11.0 160 325 1074 8.5 1.7 11.0 190 355 1287 15.0 1.7 12.0 160 340 1051 8.5 1.8 13.0 160 355 1261 5.5 1.9 13.0 190 385 1449 8.0 1.9 14.0 192 402 1770 10.0 2.0

Transmission & Distribution Length Tip Butt Mass Strength Planting Depth m mm mm kg kN m 15.6 264 498 2872 15.0 2.20 15.6 264 498 2954 25.0 2.20 15.6 264 498 2984 30.0 2.20 16.8 228 480 2825 18.0 2.30 16.8 228 480 3034 32.0 2.30 16.8 300 552 4140 50.0 2.30 16.8 300 552 4424 55.0 2.30 18.0 228 498 3076 15.0 2.40 18.0 228 498 3250 28.0 2.40 18.0 228 498 3328 36.0 2.40 18.0 300 570 4822 50.0 2.40 19.2 264 552 4242 25.0 2.50 19.2 300 588 4856 36.0 2.50 19.2 300 588 4989 50.0 2.50 19.2 372 660 6003 65.0 2.50 21.0 300 615 4960 21.0 2.70 21.0 300 615 5084 32.0 2.70 21.0 300 615 5343 50.0 2.70 24.0 300 660 6140 32.0 3.00 24.0 300 660 6510 40.0 3.00 24.0 300 660 6532 50.0 3.00

Jointed Sections Length Tip Butt Mass Strength Planting Depth m mm mm kg kN m 26.4 300 696 9038 50.0 3.20 28.8 300 732 10413 50.0 3.50 31.2 300 768 11680 50.0 3.70 33.6 300 804 13347 50.0 4.00 36.0 300 804 15040 50.0 4.20

Double Poles Length Tip Butt Mass Strength Planting Depth m mm mm kg kN m 19.2 372 660 12006 206 2.50 21.0 300 615 10686 156 2.70 24.0 300 660 13064 156 3.00

Page 7: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

SECTION B

TREATING CHEMICAL

Page 8: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

Creosote Chemical

5Litre Containers

20 Litre Containers

200 Litre Container

Page 9: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

SECTION C

ELECTRICAL NETWORK PRODUCTS

Page 10: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

4) Electrical Products and Networks

i) Fuse cut-outs: "Dropout Type" Mv

Page 11: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

Cat N° NSN N° Masse (kg) NCX 11/22 kV _ 7.26 NCX 33 kV _ _

Available in 11kV, 22kV, 33kV

Can take fuse elements form 1A to 100A

Fuse tube can be removed and a solid disconnect blade inserted converting the unit to a 300A disconnect switch

Higher amp ratings available on request

ii) Strain clamps

House Service Strain Clamp PA 25/4 Type

Used for 2x16 - 2x35 also for 4x16 - 4x25

Adjustment on wire bail allows easy sag adjustment

UV stabilized thermo-plastic body and wedge

LV Strain Clamp PA 1500 Type

Page 12: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

Suitable for insulated neutral 54.6 and 70mm

Black wedge and wire bail to identify insulated neutral clamp

Wedge means no tools are required to install

Minimum breaking load 1500 kgs

M16 Pigtail must be ordered separately

Cat N° NSN N° Insulated Neutral (mm²) Weight (kg)

PA 1500 5975-70-009-6939 54.6-70 0.45

Lightning arrestors JOSLYN MV from 3 to 765KV

Page 13: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

iii) Porcelain housed from 3kV to 765kV iv) Unique centre vent metal oxide block allows fault current up to 80kA v) Polymer housed up to 192kV ensures lightweight single stack design which is explosion proof. IEC class 2 & 3

available vi) Heavy duty metal oxide valve elements ensure low discharge characteristics

Page 14: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

Lightning arrestors JOSLYN MT from 3 to 36KV

Available in porcelain and polymer housing

All distribution class arresters fitted with automatic ground lead disconnectors

Gapless metal oxide and gapped silicon carbide available

Reference Body Class (kV) Approximate Mass (kg)

8134C0003J011 Porcelain 3 2.16

8134C0006J011 Porcelain 6 2.62

8134C0012J011 Porcelain 12 4.20

8134C0024J011 Porcelain 24 6.94

8134C0036J011 Porcelain 36 10.28

8154C0012J005 Polymer 12 2.8

8154C0024J005 Polymer 24 4.14

Page 15: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

5) Insulators

Porcelain insulator

Line post 4kN capless

Line post 12.5kN metal cap

Long rod 40kN

Cat N° Type kN Weight (kg)

932006 Line Post 4 6.52

932004 Line Post 12.5 6.66

932002 Line Post 40 6.62

Page 16: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

Ceramic Insulators

Porcelain Guy Strain

Page 17: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

Used in normal lightning areas

Different sizes for LV and HV applications

Cat N° NSN N° D-DT N° Weight (kg)

EBM1075 5970-70-010-8276 3144/1 0.374

EBM522 5970-70-404-0113 3144/2 1.320

6) Lightning Arrestors

Lightning arrestors JOSLYN MV from 3 to 765KV

Porcelain housed from 3kV to 765kV

Unique centre vent metal oxide block allows fault current up to 80kA

Polymer housed up to 192kV ensures lightweight single stack design which is explosion proof. IEC class 2 & 3 available

Heavy duty metal oxide valve elements ensure low discharge characteristics

Reference Body Class (kV)

ZIP0012-1231 Polymer 12

Page 18: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

ZIP0024-1231 Polymer 24

ZIP0036-1231 Polymer 36

ZIP0060-1231 Polymer 60

ZIP0072-1231 Polymer 72

ZIP0120-1231 Polymer 120

8110D000IJ012 Porcelain 12

8110D000IJ024 Porcelain 24

8110D000IJ036 Porcelain 36

Lightning arrestors JOSLYN MT from 3 to 36KV

Available in porcelain and polymer housing

All distribution class arresters fitted with automatic ground lead disconnectors

Gapless metal oxide and gapped silicon carbide available

Reference Body Class (kV) Approximate Mass (kg)

8134C0003J011 Porcelain 3 2.16

8134C0006J011 Porcelain 6 2.62

8134C0012J011 Porcelain 12 4.20

8134C0024J011 Porcelain 24 6.94

8134C0036J011 Porcelain 36 10.28

8154C0012J005 Polymer 12 2.8

8154C0024J005 Polymer 24 4.14

Page 19: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

7) Insulation piercing connectors

Insulation piercing connector - PC1WP1F Type

EBM type connector for street lighting and small consumers house connections up to 10mm²

Suitable for live line tapping into aerial bundle conductor Al-Al or Al-Cu

Water tight connection withstanding 6kV flashover in water

Shear head

Single bolt wide range connector

Cat N° Main conductor Tap conductor

PC1WP1F 16mm²-95mm² 1.5mm²-10mm²

Page 20: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

Insulation piercing connector - PC 2-1 Type

EBM type connector

Suitable for live line tapping into aerial bundle conductor Al-Al or Al-Cu

Water-tight connector withstanding 6kV flashover in water

Single shear head bolt A/F 13mm

Cat N° Main conductor Tap conductor

PC 2-1 25mm²-95mm² 4mm²-35mm²

Page 21: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

Insulation piercing connector - PC3WP2F Type

EBM type connector for heavy duty full line current applications

Suitable for live line tapping into aerial bundle conductor Al-Al or Al-Cu

Water tight connection withstanding 6kV flashover in water

Double bolts shear head with four contact plates

Separate caps balance the connector geometry and a low stable contact resistance

Tap conductor may leave either side

Double bolt with torque shear head nuts

Cat N° Main conductor Tap conductor

PC3WP2F 25mm²-95mm² 25mm²-95mm²

Page 22: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

8) Street Lighting

i) Apollo

A new range of high performance, cost effective streetlights.

Main features

Efficient reflector system, the back reflector has a shaped center portion to reduce “shine back “ into the lamp

High impact acrylic bowl with three stainless steel clips with an IP rating of 65 in the lamp compartment

Gear cover lid held in place with two stainless steel clips, with an IP rating of 43 in the gear compartment

Removable gear tray

Provision for nema base and/or MCB

Adjustable spigot entry suitable for 32mm to 42mm

Available in the following Wattage

Lamp type Power (Watts)

Mercury vapour 80W; 125W

High pressure sodium 70W; 100W; 150W

Fluorescent 2 x 26W PL

Incandescent No gear tray, E27 or E40 lampholder

Page 23: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

Skylight MK IV

An improved version of the skylight range of streetlights.

Main features

Efficient reflector system, the back reflector has a shaped center to reduce “shine back“ into the lamp

High impact acrylic bowl with three stainless stell clips with an IP rating of 55 in the lamp compartment

Gear cover lid held in place with two stainless steel clips with an IP rating of 43 in the gear compartment

Removable gear tray

Provision for nema base and/or MCB

Adjustable spigot entry suitable for 32mm to 45mm

Available in the following Wattage

Lamp type Power (Watts)

Mercury vapour 250W; 400W

High pressure sodium 150W; 250W; 400W

Incandescent No gear tray, E27 or E40 lampholder

Page 24: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

8. Outdoor architectural lighting

Drive over Sparks Ring

Flat Flat Quadrata Bowl

Prado

Walk over Compact Tonda Compact Quadra

Plano Linear Microled

Micro Sparks Led Zip Led RGB Zip Led Quadrata

Zip Tonda Zip Quadrata

Page 25: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

Wall recesse

EOS Strip Diapason

Brique Tonda Brique Quadra Brique

Flat Ring Sparks

Prado MicroPlug MicroLed

Downlighters

Focus Zip Down Tonda Zip Down Quadra

Page 26: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

Flat Down Prado Down Slot

Bollards

Column Testa Piatta Column Testa Tonda Jet

Minireef Miniriff Paletto Reef

Reef Paletto Reef Paletto Music EOS Palo

Strip Palo Airone Scherma

Wall mounted

Linear Blitz Lift Quadra

Page 27: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

Lift Rect Slot Vedo Tonda

Vedo Ovale Scherma Bul

Plafo Wip Applique

Floodlights

Focus Techno Spot Techno Rect Flood

Techno Rect Spot Wip Ibiza

Urban lighting

Slot Palogold Minislot Dis Minislot Avant-Garde

Page 28: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

Minislot Avant-Garde Slot Vela Slot Vela Doppio

Techno Power Slot for Pole

Submersion

Sub

9. Flameproof lighting

Fluorescent Polyester Zone 1 - Hazardous Area

Fluorescent GRP luminaire, with G13 lampholders for use with standard 2 pin lamps.

Main features

2x18W ; 2x36W ; 2x58W

Electronic ballast

50-60Hz ; 230V

Temperature class T4

Gas group II

Page 29: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

Fluorescent Stainless steel Zone 1 - Hazardous Area

Fluorescent stainless steel luminaire with G13 lampholders for use with standard 2 pin lamps.

Main features

Electronic ballast

2x18W ; 2x36W ; 2x58W

50-60Hz ; 230V

Temperature class T4

Gas group II

Cast iron pendant fitting for mines or surface Zone 1 - Hazardous Area

Cast iron pendant fitting, for zone 1 (Explosive atmosphere under normal operating conditions).

Applications

For use in fiery mines and sSurface industries

Main features

Hydrogen: Not suitable for hydrogen atmospheres

Conformes SABS 314

The enclosure is rated for gas groups I, II A, II B: B

Aluminium pendants for Zone 1 - Hazardous Area

Pendants for use in locations where the atmosphere is likely to be potentially explosive under normal operating conditions ie. zone 1.

Page 30: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

Applications

Surface only

Main features

Suitable for Hydrogen

Conforms to SABS 314

Gas group II, zone 1

E27 lamp holder, 200W maximum

Aluminium bulkhead for Zone 1 - Hazardous Area

Surface only bulhead light (not for mines).

Main features

Increased safety bulkhead

E27 lamp holder

Maximum power 100W

Gas group IIIC

PTB no III B/E-24 746

Page 31: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

10. Flameproof control stations

Padlockable emergency stop station Zone 1 - Hazardous Area

Cast iron or aluminium flameproof stop station, with padlockable stainless steel button.

Main features

Zone 1

Gas groups I, IIA, IIB, IIC

IEC 60079-1

Upon request:

Stainless steel enclosure

Special paint

Other configurations on request

Emergency stop station Zone 1 - Hazardous Area

Flameproof steel emergency stop station.

Page 32: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

Main features

Zone 1

Gas Group I, IIA, II B + Hydrogen

IEC 60079-1

Upon request:

Stainless steel enclosure

Special paint

Cadmium plating

Other configurations on request

Stop-Start station Zone 1 - Hazardous Area

Steel flameproof enclosure, with stop start buttons.

Main features

Zone 1

Gas Group I, IIA, II B + Hydrogen

IEC 60079-1

Upon request:

Stainless steel enclosure

Special paint

Cadmium plating

Other configurations on request

Page 33: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

Direct online starter Zone 1 - Hazardous Area

Flameproof steel D.O.L. starter.

Main features

Zone 1

Gas Group I, IIA, II B + Hydrogen

IEC 60079-1

Upon request:

Stainless steel enclosure

Special paint

Cadmium plating

Other configurations on request

Control Panel Zone 1 - Hazardous Area

Control panel for conveyor belt and pump.

Main features

Zone 1

Gas Group I

3P+N 90 KVA, 1000V

IEC 60079-1

Other configurations on request

Page 34: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

Control Panel for oil refinery Zone 1 - Hazardous Area

Control Panel for ENGEN oil refinery in Durban (South Africa) using a combination of flameproof and increased safety technologies: (EXe and EXd).

Main features

Stainless Steel enclosures

Gas group II B

EC 60079-1

11. Flameproof control panels

Page 35: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

12. Flame Proof Lighting

Fluorescent Polyester Zone 1 - Hazardous Area

Fluorescent GRP luminaire, with G13 lampholders for use with standard 2 pin lamps.

Main features

2x18W ; 2x36W ; 2x58W

Electronic ballast

50-60Hz ; 230V

Temperature class T4

Gas group II

Fluorescent Stainless steel Zone 1 - Hazardous Area

Fluorescent stainless steel luminaire with G13 lampholders for use with standard 2 pin lamps.

Main features

Electronic ballast

2x18W ; 2x36W ; 2x58W

50-60Hz ; 230V

Temperature class T4

Gas group II

Page 36: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

Cast iron pendant fitting for mines or surface Zone 1 - Hazardous Area

Cast iron pendant fitting, for zone 1 (Explosive atmosphere under normal operating conditions).

Applications

For use in fiery mines and sSurface industries

Main features

Hydrogen: Not suitable for hydrogen atmospheres

Conformes SABS 314

The enclosure is rated for gas groups I, II A, II B: B

Aluminium pendants for Zone 1 - Hazardous Area

Pendants for use in locations where the atmosphere is likely to be potentially explosive under normal operating conditions ie. zone 1.

Applications

Surface only

Main features

Suitable for Hydrogen

Conforms to SABS 314

Gas group II, zone 1

E27 lamp holder, 200W maximum

Page 37: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

Aluminium bulkhead for Zone 1 - Hazardous Area

Surface only bulhead light (not for mines).

Main features

Increased safety bulkhead

E27 lamp holder

Maximum power 100W

Gas group IIIC

PTB no III B/E-24 746

12. Energy Meters

repayment meter : Ecolec 570

Miniature meters : Ecolec 100 Series Compact Rail-Mounted Meter

Ecolec 100 Series Compact Rail-Mounted Meter

IEC 61036 Class 2 electricity meters

Single, dual and three phase alternatives

Fits all Mini and Din rail distribution boards

7 digit indication of energy consumed to 1/10 kWh

Dual colour lamp shows rate of consumption and/or confirms presence of incoming supply

Supplied with anti-tamper terminal protection plugs

Also available in 120V/60HzCompteurs électriques Classe 2 suivant IEC 61036

Page 38: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

Key benefits

Compact size drastically reduces enclosure costs

Low burden and superior sensitivity for low usage consumers

Extended operating ranges for rural reticulation extremes

Absence of electronic storage eliminates meter data corruption

Reverse connected meter measures consumption correctly

Built-in self test, warning or failure indication on dual colour LED

Electronic pulse output or serial data stream via SLMS port

Withstands 10kV lightning and 1kV DC insulation testing voltages

Tamper proof terminal covers with optional grommets, reduce losses

Pulse output indicator confirms availability of supply when load disconnected

Nominal Voltage (Un) 120V or 230V AC

Operational Frequency Range 54 to 66Hz or 45 to 55Hz

Operational Voltage Range 60 to 180V or 100 to 360V

Over Voltage Withstand 600V AC for 48 hours

DC Voltage Withstand 1000V DC for 1 minute

Impulse Voltage Withstand 10kV differential mode

ESD Withstand 15kV air discharge

Basic Current (Ib) 5 Amps

Maximum Rated Current (Imax) 65 Amps

Operational Current Range 20mA to 90 Amps

Overcurrent Withstand 120 Amps for 48 hours

180 Amps for 1 minute

Fault Current Withstand 5kA for 10mS

Voltage Circuit Burden 0.2 Watts and 4 VA

LED Output Flash Rate 1000 impulses per kWh

Declared Accuracy at 0.1A ±5%

Accuracy Class Class 2

Protection Class Class 2, double insulated

Operating Temperature Storage Temperature -100C to 600C

Storage temperature -250C to 800C

Page 39: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

SECTION D

ELECTRICAL CABLES

Page 40: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

Types of Cables

Building Cables:

Communication and Telecommunication Cables:

Sourced from the most respected manufacturers, there are a wide variety of high quality solutions available designed to meet the demands of industry standards such as RS484, RS 232 and RS 422.

The company's extensive portfolio includes high performance Cat 5 and Cat 6 cables designed to support a frequency range of up to 100 MHz with transmission speeds of up to 1 Gigabit per second.

Rail and Transport

Electricity Transmission Cables:

Page 41: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

PRODUCT DETAILS:

BS125 BS 215 BS 4066

BS 2E21 BS 5308 BS 5467

BS 6004 BS 6007 BS 6121

BS 6141 BS 6195 BS 6231

Page 42: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

BS 6346 BS 6360 BS 6469

BS 6480 BS 6500 BS 6622

BS 6724 BS 6883 BS 60228

BS 638 BS 7211 BS 7629

Page 43: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

BS 7835 BS 7870 BS 7884

BS 7919 BS 6004 BS 6500

BS 6622 CSA 22.23 DIN VDE 250

DIN VDE 262 DIN VDE 266 DIN VDE 271

Page 44: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

DIN VDE 276 DIN VDE 277 DIN VDE 281

EIA RS 232 H03VV-F H05BN4-F

UL 758 H05VV-F H07BN4-F

H07V-K TIA/EIA 568 RS 422

Page 45: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

USES AND SPECIFICATIONS

1. BS 125 Electric conductors, copper and copper-cadmium, for overhead transmission 2. BS 215 Electric conductors, aluminium and steel- cored aluminium 3. BS 4066 Electric cables, tests under fire conditions 4 BS 2 E 21 Pren type electric cables for aircraft. 5. BS 5308 Part 1 Insulated cables, instrumentation, intrinsically safe 6. BS 5308 Part 2 Insulated cables, instrumentation, intrinsically safe 7. BS 5467 Power cables, armoured thermosetting-polymer insulated, for electricity supply 8. BS 6004 Insulated cables PVC insulated, non armoured 9. BS 6007 : 2006 Electric cables. Single core unsheathed heat resisting cables for voltages up to and including

450/750V, for internal wiring 10. BS 6121 Mechanical cable glands 11. BS 6141 Flexible conductors, for high temperature zones; this standard has been withdrawn and replaced

by tables in BS 6004:2000, BS 6007:2000, BS6500:2000 and BS 7919:2001 12. BS 6195 : 2006 Electric cables. Rubber or silicone rubber insulated flexible cables and cords for coil end leads 13. BS 6231:2006 Electric cables. Single core PVC insulated flexible cables of rated voltage 600/1000V for switchgear

and control gear wiring 14. BS 6346 : 1997 Electric cables, PVC insulated, armoured cables for voltages of 600/1000V and 1900/3300V 15. BS 6360 : 1991 Specification for conductors in insulated cables and cords. This standard is obsolete and will be

replaced by BS EN 60228. 16. BS 6469: section 99.1:

1992 Insulating , sheathing materials of electric cables, non electrical tests

17 BS 6480 Specification for impregnated paper- insulated lead or lead alloy sheathed electric cables of rated voltages up to and including 33000V

18. BS 6500:2000 Electric cables. Flexible cords rated up to 300/500V, for use with appliances and equipment intended for domestic, office and similar environments

19. BS 6622:1999 Cables with extruded cross linked polyethylene or ethylene propylene rubber insulation 3.8/6.6kV to 19/33kV

20. BS 6724:1997 600/1000V, 1900/3300V armoured electric cable with thermosetting insulation and low emission smoke, gases

21. BS 6883:1999 Elastomer insulated cables for fixed wiring in ships 22. BS 60228:2005 Conductors of insulated cables 23. BS 638:Part4:1996 Arc welding power sources, equipment and accessories. Specification for welding cables 24. BS 7211:1998 Thermosetting insulated cables, non armoured, with low smoke and gas 25. BS 7629 Part 1 Specification for 300/500V fire resistant electric cable having low emission of smoke and corrosive

gases when affected by fire multicore cables 26. BS 7629 Part 2 Specification for 300/500V fire resistant electric cable having low emission of smoke and corrosive

gases when affected by fire multipair cables 27. BS 7835 Specification for armoured cables with extruded cross-linked polyethylene or ethylene propylene

rubber insulation for rated voltages from 3.8/6.6kV up to 19/33kV having low emission of smoke and corrosive gases when affected by fire

28. BS 7870 LV and MV polymeric insulated cables for use by distribution and generation utilities. General 29. BS 7884:1997 Specification for copper and copper- cadmium stranded conductors for overhead electric traction

and power transmission systems. 30. BS 7919:2001 Electric cables. Flexible cables rated up to 450/750V, for use with appliances and equipment

intended for industrial and similar environments 31. Generally to

BS 6004 Insulated cables, PVC insulated, non armoured

32. Generally to BS 6500

Flexible cables, insulated cords and cables

33. CSA 22.23 No 127 Type TEW

Equipment and Lead Wires

34. CW 1128 Specification CW 1128 for cable polyethylene twin and polyethylene twin - screened 35. DIN VDE 250 Part 1 to

part 819 Cables, wires and flexible cords for power installation

Page 46: PRODUCT LISTimgusr.tradekey.com/.../uploadedimages/brochures/2/...PRODUCT BROCHURE 2012 3) CONCRETE TRANSMISSION POLES Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry

PRODUCT BROCHURE

2012

36. DIN VDE 262 XLPE insulated and PVC sheathed installation cable up to0.6/1kV 37. DIN VDE 266 Part 3 and

4 Halogen free cables with improved characteristics in the case of fire- nominal voltages 6 to 30kV

38. DIN VDE 271 PVC insulated cables rated voltages up to and including 3.6/6(7.2)kV 39. DIN VDE 276 Part 603 Distribution cables of nominal voltages Uo/U 0.6/1kV 40. DIN VDE 276 Part 604 Power cables of nominal voltages Uo/U 0.6/1kV with special fire performance for use in power

stations 41. DIN VDE 276 Part

604/605 Additional test methods

42. DIN VDE 276 Part 620 Distribution cables of nominal voltages Uo/U 3.6kV to 20.8/36kV 43. DIN VDE 277 Airport lighting 44. DIN VDE 281 part 1 to

part 404 PVC cables, wires and flexible cords for power installation

45. DIN VDE 282 Part 1 to Part 808

Rubber cables and flexible cords for power installation, heat resistant silicone rubber insulated cable, halogen free insulated cable, arc welding cable, rubber insulated lift cable, rubber sheathed flexible cables

46. EIA RS 232 TIA/EIA standard for serial transmission between computers and peripheral devices 47. H03VV-F Circular, PVC insulation/PVC sheathed 300/300V, to BS 6500 48. H05BN4-F Single Core, Rubber insulated, HOFR sheathed, 450/750V 49. H05V-K Single core, PVC insulated only, 300/300V 50. H05VV-F PVC insulated and sheathed, 300/500V 51. H07BN4-F Single core, Rubber insulated, HOFR sheathed, 450/750V 52. H07V-K Single core, PVC insulated only, 450/750V, Flexible conductor 53. H07V-R Single core, PVC insulated only, 450/750V, Stranded conductor 54. H07V-R Single core, PVC insulated only, 450/750V, Stranded conductor 55. IEC 60598-1 Luminaries- General requirements and tests 56. RS 422 Electrical characteristics of the balanced voltage digital interface circuit 57. TIA/EIA 568 Commercial Building Telecommunications Wiring Standard Part 1 : General Requirements 58. UL 758 Appliance wiring Material