PRODUCT BROCHURE
2012
PRODUCT LIST
PRODUCT BROCHURE
2012
SECTION A
ELECTRICITY TRANSMISSION EQUIPMENT
PRODUCT BROCHURE
2012
1) WOODEN TREATED POLES – FENCING AND TRANSMISSION
We are able to supply the market with poles of lengths diameters and sizes. We produce international standard poles
and will treat them with either CCA or Creosote. Its up to you to choose.
CCA
Creosote
Avaibalve Lengths:
1.8m, 2.1m, 2.4m, 2.7m, 3.0m, 3.6m, 4.2m, 4.8m, 5.4m, 6.0m, 6.6m, 7.2m, 9.0m, 10.0m, 11.0m, 12.0m
Available Diameters:
25-50mm
50-75mm
75-100mm
125-150mm
160-180mm
180-200mm
Soecifications Applicable:
SABS
SAZ
PRODUCT BROCHURE
2012
2) STEEL UTILITY POLES
PRODUCT BROCHURE
2012
3) CONCRETE TRANSMISSION POLES
Spun Concrete Poles Pole Size Length Tip Butt Mass Cable Entry Inspection Box Strength Planting Depth M mm mm t mm mm kN m 4.5 115 183 0.210 150 x 75 465 x 145 2.5 1.00 4.5 130 198 0.237 150 x 75 465 x 145 2.5 1.00 6.0 115 205 0.307 150 x 75 465 x 145 2.5 1.20 6.0 130 220 0.346 150 x 75 465 x 145 2.5 1.20 7.5 115 228 0.419 150 x 75 465 x 145 2.5 1.35 7.5 130 243 0.473 150 x 75 465 x 145 2.5 1.35 8.0 130 250 0.522 150 x 75 465 x 145 2.5 1.40 9.0 130 265 0.617 150 x 75 465 x 145 2.5 or 5.5 1.50 10.0 130 280 0.720 150 x 75 465 x 145 5.5 1.60 11.0 130 295 0.828 150 x 75 465 x 145 5.5 1.70 12.0 130 310 0.967 150 x 75 465 x 145 5.5 1.80 13.0 130 325 1.066 150 x 75 465 x 145 5.5 1.90
Reticulation Length Tip Butt Mass Strength Planting Depth M mm mm kg kN m 7.0 130 235 434 3.5 1.3
PRODUCT BROCHURE
2012
9.0 160 295 646 5.5 1.5 9.0 160 295 807 8.5 1.5 9.0 190 325 950 12.0 1.5 10.0 160 310 866 5.5 1.6 10.0 190 340 1095 12.0 1.6 11.0 160 325 1074 8.5 1.7 11.0 190 355 1287 15.0 1.7 12.0 160 340 1051 8.5 1.8 13.0 160 355 1261 5.5 1.9 13.0 190 385 1449 8.0 1.9 14.0 192 402 1770 10.0 2.0
Transmission & Distribution Length Tip Butt Mass Strength Planting Depth m mm mm kg kN m 15.6 264 498 2872 15.0 2.20 15.6 264 498 2954 25.0 2.20 15.6 264 498 2984 30.0 2.20 16.8 228 480 2825 18.0 2.30 16.8 228 480 3034 32.0 2.30 16.8 300 552 4140 50.0 2.30 16.8 300 552 4424 55.0 2.30 18.0 228 498 3076 15.0 2.40 18.0 228 498 3250 28.0 2.40 18.0 228 498 3328 36.0 2.40 18.0 300 570 4822 50.0 2.40 19.2 264 552 4242 25.0 2.50 19.2 300 588 4856 36.0 2.50 19.2 300 588 4989 50.0 2.50 19.2 372 660 6003 65.0 2.50 21.0 300 615 4960 21.0 2.70 21.0 300 615 5084 32.0 2.70 21.0 300 615 5343 50.0 2.70 24.0 300 660 6140 32.0 3.00 24.0 300 660 6510 40.0 3.00 24.0 300 660 6532 50.0 3.00
Jointed Sections Length Tip Butt Mass Strength Planting Depth m mm mm kg kN m 26.4 300 696 9038 50.0 3.20 28.8 300 732 10413 50.0 3.50 31.2 300 768 11680 50.0 3.70 33.6 300 804 13347 50.0 4.00 36.0 300 804 15040 50.0 4.20
Double Poles Length Tip Butt Mass Strength Planting Depth m mm mm kg kN m 19.2 372 660 12006 206 2.50 21.0 300 615 10686 156 2.70 24.0 300 660 13064 156 3.00
PRODUCT BROCHURE
2012
SECTION B
TREATING CHEMICAL
PRODUCT BROCHURE
2012
Creosote Chemical
5Litre Containers
20 Litre Containers
200 Litre Container
PRODUCT BROCHURE
2012
SECTION C
ELECTRICAL NETWORK PRODUCTS
PRODUCT BROCHURE
2012
4) Electrical Products and Networks
i) Fuse cut-outs: "Dropout Type" Mv
PRODUCT BROCHURE
2012
Cat N° NSN N° Masse (kg) NCX 11/22 kV _ 7.26 NCX 33 kV _ _
Available in 11kV, 22kV, 33kV
Can take fuse elements form 1A to 100A
Fuse tube can be removed and a solid disconnect blade inserted converting the unit to a 300A disconnect switch
Higher amp ratings available on request
ii) Strain clamps
House Service Strain Clamp PA 25/4 Type
Used for 2x16 - 2x35 also for 4x16 - 4x25
Adjustment on wire bail allows easy sag adjustment
UV stabilized thermo-plastic body and wedge
LV Strain Clamp PA 1500 Type
PRODUCT BROCHURE
2012
Suitable for insulated neutral 54.6 and 70mm
Black wedge and wire bail to identify insulated neutral clamp
Wedge means no tools are required to install
Minimum breaking load 1500 kgs
M16 Pigtail must be ordered separately
Cat N° NSN N° Insulated Neutral (mm²) Weight (kg)
PA 1500 5975-70-009-6939 54.6-70 0.45
Lightning arrestors JOSLYN MV from 3 to 765KV
PRODUCT BROCHURE
2012
iii) Porcelain housed from 3kV to 765kV iv) Unique centre vent metal oxide block allows fault current up to 80kA v) Polymer housed up to 192kV ensures lightweight single stack design which is explosion proof. IEC class 2 & 3
available vi) Heavy duty metal oxide valve elements ensure low discharge characteristics
PRODUCT BROCHURE
2012
Lightning arrestors JOSLYN MT from 3 to 36KV
Available in porcelain and polymer housing
All distribution class arresters fitted with automatic ground lead disconnectors
Gapless metal oxide and gapped silicon carbide available
Reference Body Class (kV) Approximate Mass (kg)
8134C0003J011 Porcelain 3 2.16
8134C0006J011 Porcelain 6 2.62
8134C0012J011 Porcelain 12 4.20
8134C0024J011 Porcelain 24 6.94
8134C0036J011 Porcelain 36 10.28
8154C0012J005 Polymer 12 2.8
8154C0024J005 Polymer 24 4.14
PRODUCT BROCHURE
2012
5) Insulators
Porcelain insulator
Line post 4kN capless
Line post 12.5kN metal cap
Long rod 40kN
Cat N° Type kN Weight (kg)
932006 Line Post 4 6.52
932004 Line Post 12.5 6.66
932002 Line Post 40 6.62
PRODUCT BROCHURE
2012
Ceramic Insulators
Porcelain Guy Strain
PRODUCT BROCHURE
2012
Used in normal lightning areas
Different sizes for LV and HV applications
Cat N° NSN N° D-DT N° Weight (kg)
EBM1075 5970-70-010-8276 3144/1 0.374
EBM522 5970-70-404-0113 3144/2 1.320
6) Lightning Arrestors
Lightning arrestors JOSLYN MV from 3 to 765KV
Porcelain housed from 3kV to 765kV
Unique centre vent metal oxide block allows fault current up to 80kA
Polymer housed up to 192kV ensures lightweight single stack design which is explosion proof. IEC class 2 & 3 available
Heavy duty metal oxide valve elements ensure low discharge characteristics
Reference Body Class (kV)
ZIP0012-1231 Polymer 12
PRODUCT BROCHURE
2012
ZIP0024-1231 Polymer 24
ZIP0036-1231 Polymer 36
ZIP0060-1231 Polymer 60
ZIP0072-1231 Polymer 72
ZIP0120-1231 Polymer 120
8110D000IJ012 Porcelain 12
8110D000IJ024 Porcelain 24
8110D000IJ036 Porcelain 36
Lightning arrestors JOSLYN MT from 3 to 36KV
Available in porcelain and polymer housing
All distribution class arresters fitted with automatic ground lead disconnectors
Gapless metal oxide and gapped silicon carbide available
Reference Body Class (kV) Approximate Mass (kg)
8134C0003J011 Porcelain 3 2.16
8134C0006J011 Porcelain 6 2.62
8134C0012J011 Porcelain 12 4.20
8134C0024J011 Porcelain 24 6.94
8134C0036J011 Porcelain 36 10.28
8154C0012J005 Polymer 12 2.8
8154C0024J005 Polymer 24 4.14
PRODUCT BROCHURE
2012
7) Insulation piercing connectors
Insulation piercing connector - PC1WP1F Type
EBM type connector for street lighting and small consumers house connections up to 10mm²
Suitable for live line tapping into aerial bundle conductor Al-Al or Al-Cu
Water tight connection withstanding 6kV flashover in water
Shear head
Single bolt wide range connector
Cat N° Main conductor Tap conductor
PC1WP1F 16mm²-95mm² 1.5mm²-10mm²
PRODUCT BROCHURE
2012
Insulation piercing connector - PC 2-1 Type
EBM type connector
Suitable for live line tapping into aerial bundle conductor Al-Al or Al-Cu
Water-tight connector withstanding 6kV flashover in water
Single shear head bolt A/F 13mm
Cat N° Main conductor Tap conductor
PC 2-1 25mm²-95mm² 4mm²-35mm²
PRODUCT BROCHURE
2012
Insulation piercing connector - PC3WP2F Type
EBM type connector for heavy duty full line current applications
Suitable for live line tapping into aerial bundle conductor Al-Al or Al-Cu
Water tight connection withstanding 6kV flashover in water
Double bolts shear head with four contact plates
Separate caps balance the connector geometry and a low stable contact resistance
Tap conductor may leave either side
Double bolt with torque shear head nuts
Cat N° Main conductor Tap conductor
PC3WP2F 25mm²-95mm² 25mm²-95mm²
PRODUCT BROCHURE
2012
8) Street Lighting
i) Apollo
A new range of high performance, cost effective streetlights.
Main features
Efficient reflector system, the back reflector has a shaped center portion to reduce “shine back “ into the lamp
High impact acrylic bowl with three stainless steel clips with an IP rating of 65 in the lamp compartment
Gear cover lid held in place with two stainless steel clips, with an IP rating of 43 in the gear compartment
Removable gear tray
Provision for nema base and/or MCB
Adjustable spigot entry suitable for 32mm to 42mm
Available in the following Wattage
Lamp type Power (Watts)
Mercury vapour 80W; 125W
High pressure sodium 70W; 100W; 150W
Fluorescent 2 x 26W PL
Incandescent No gear tray, E27 or E40 lampholder
PRODUCT BROCHURE
2012
Skylight MK IV
An improved version of the skylight range of streetlights.
Main features
Efficient reflector system, the back reflector has a shaped center to reduce “shine back“ into the lamp
High impact acrylic bowl with three stainless stell clips with an IP rating of 55 in the lamp compartment
Gear cover lid held in place with two stainless steel clips with an IP rating of 43 in the gear compartment
Removable gear tray
Provision for nema base and/or MCB
Adjustable spigot entry suitable for 32mm to 45mm
Available in the following Wattage
Lamp type Power (Watts)
Mercury vapour 250W; 400W
High pressure sodium 150W; 250W; 400W
Incandescent No gear tray, E27 or E40 lampholder
PRODUCT BROCHURE
2012
8. Outdoor architectural lighting
Drive over Sparks Ring
Flat Flat Quadrata Bowl
Prado
Walk over Compact Tonda Compact Quadra
Plano Linear Microled
Micro Sparks Led Zip Led RGB Zip Led Quadrata
Zip Tonda Zip Quadrata
PRODUCT BROCHURE
2012
Wall recesse
EOS Strip Diapason
Brique Tonda Brique Quadra Brique
Flat Ring Sparks
Prado MicroPlug MicroLed
Downlighters
Focus Zip Down Tonda Zip Down Quadra
PRODUCT BROCHURE
2012
Flat Down Prado Down Slot
Bollards
Column Testa Piatta Column Testa Tonda Jet
Minireef Miniriff Paletto Reef
Reef Paletto Reef Paletto Music EOS Palo
Strip Palo Airone Scherma
Wall mounted
Linear Blitz Lift Quadra
PRODUCT BROCHURE
2012
Lift Rect Slot Vedo Tonda
Vedo Ovale Scherma Bul
Plafo Wip Applique
Floodlights
Focus Techno Spot Techno Rect Flood
Techno Rect Spot Wip Ibiza
Urban lighting
Slot Palogold Minislot Dis Minislot Avant-Garde
PRODUCT BROCHURE
2012
Minislot Avant-Garde Slot Vela Slot Vela Doppio
Techno Power Slot for Pole
Submersion
Sub
9. Flameproof lighting
Fluorescent Polyester Zone 1 - Hazardous Area
Fluorescent GRP luminaire, with G13 lampholders for use with standard 2 pin lamps.
Main features
2x18W ; 2x36W ; 2x58W
Electronic ballast
50-60Hz ; 230V
Temperature class T4
Gas group II
PRODUCT BROCHURE
2012
Fluorescent Stainless steel Zone 1 - Hazardous Area
Fluorescent stainless steel luminaire with G13 lampholders for use with standard 2 pin lamps.
Main features
Electronic ballast
2x18W ; 2x36W ; 2x58W
50-60Hz ; 230V
Temperature class T4
Gas group II
Cast iron pendant fitting for mines or surface Zone 1 - Hazardous Area
Cast iron pendant fitting, for zone 1 (Explosive atmosphere under normal operating conditions).
Applications
For use in fiery mines and sSurface industries
Main features
Hydrogen: Not suitable for hydrogen atmospheres
Conformes SABS 314
The enclosure is rated for gas groups I, II A, II B: B
Aluminium pendants for Zone 1 - Hazardous Area
Pendants for use in locations where the atmosphere is likely to be potentially explosive under normal operating conditions ie. zone 1.
PRODUCT BROCHURE
2012
Applications
Surface only
Main features
Suitable for Hydrogen
Conforms to SABS 314
Gas group II, zone 1
E27 lamp holder, 200W maximum
Aluminium bulkhead for Zone 1 - Hazardous Area
Surface only bulhead light (not for mines).
Main features
Increased safety bulkhead
E27 lamp holder
Maximum power 100W
Gas group IIIC
PTB no III B/E-24 746
PRODUCT BROCHURE
2012
10. Flameproof control stations
Padlockable emergency stop station Zone 1 - Hazardous Area
Cast iron or aluminium flameproof stop station, with padlockable stainless steel button.
Main features
Zone 1
Gas groups I, IIA, IIB, IIC
IEC 60079-1
Upon request:
Stainless steel enclosure
Special paint
Other configurations on request
Emergency stop station Zone 1 - Hazardous Area
Flameproof steel emergency stop station.
PRODUCT BROCHURE
2012
Main features
Zone 1
Gas Group I, IIA, II B + Hydrogen
IEC 60079-1
Upon request:
Stainless steel enclosure
Special paint
Cadmium plating
Other configurations on request
Stop-Start station Zone 1 - Hazardous Area
Steel flameproof enclosure, with stop start buttons.
Main features
Zone 1
Gas Group I, IIA, II B + Hydrogen
IEC 60079-1
Upon request:
Stainless steel enclosure
Special paint
Cadmium plating
Other configurations on request
PRODUCT BROCHURE
2012
Direct online starter Zone 1 - Hazardous Area
Flameproof steel D.O.L. starter.
Main features
Zone 1
Gas Group I, IIA, II B + Hydrogen
IEC 60079-1
Upon request:
Stainless steel enclosure
Special paint
Cadmium plating
Other configurations on request
Control Panel Zone 1 - Hazardous Area
Control panel for conveyor belt and pump.
Main features
Zone 1
Gas Group I
3P+N 90 KVA, 1000V
IEC 60079-1
Other configurations on request
PRODUCT BROCHURE
2012
Control Panel for oil refinery Zone 1 - Hazardous Area
Control Panel for ENGEN oil refinery in Durban (South Africa) using a combination of flameproof and increased safety technologies: (EXe and EXd).
Main features
Stainless Steel enclosures
Gas group II B
EC 60079-1
11. Flameproof control panels
PRODUCT BROCHURE
2012
12. Flame Proof Lighting
Fluorescent Polyester Zone 1 - Hazardous Area
Fluorescent GRP luminaire, with G13 lampholders for use with standard 2 pin lamps.
Main features
2x18W ; 2x36W ; 2x58W
Electronic ballast
50-60Hz ; 230V
Temperature class T4
Gas group II
Fluorescent Stainless steel Zone 1 - Hazardous Area
Fluorescent stainless steel luminaire with G13 lampholders for use with standard 2 pin lamps.
Main features
Electronic ballast
2x18W ; 2x36W ; 2x58W
50-60Hz ; 230V
Temperature class T4
Gas group II
PRODUCT BROCHURE
2012
Cast iron pendant fitting for mines or surface Zone 1 - Hazardous Area
Cast iron pendant fitting, for zone 1 (Explosive atmosphere under normal operating conditions).
Applications
For use in fiery mines and sSurface industries
Main features
Hydrogen: Not suitable for hydrogen atmospheres
Conformes SABS 314
The enclosure is rated for gas groups I, II A, II B: B
Aluminium pendants for Zone 1 - Hazardous Area
Pendants for use in locations where the atmosphere is likely to be potentially explosive under normal operating conditions ie. zone 1.
Applications
Surface only
Main features
Suitable for Hydrogen
Conforms to SABS 314
Gas group II, zone 1
E27 lamp holder, 200W maximum
PRODUCT BROCHURE
2012
Aluminium bulkhead for Zone 1 - Hazardous Area
Surface only bulhead light (not for mines).
Main features
Increased safety bulkhead
E27 lamp holder
Maximum power 100W
Gas group IIIC
PTB no III B/E-24 746
12. Energy Meters
repayment meter : Ecolec 570
Miniature meters : Ecolec 100 Series Compact Rail-Mounted Meter
Ecolec 100 Series Compact Rail-Mounted Meter
IEC 61036 Class 2 electricity meters
Single, dual and three phase alternatives
Fits all Mini and Din rail distribution boards
7 digit indication of energy consumed to 1/10 kWh
Dual colour lamp shows rate of consumption and/or confirms presence of incoming supply
Supplied with anti-tamper terminal protection plugs
Also available in 120V/60HzCompteurs électriques Classe 2 suivant IEC 61036
PRODUCT BROCHURE
2012
Key benefits
Compact size drastically reduces enclosure costs
Low burden and superior sensitivity for low usage consumers
Extended operating ranges for rural reticulation extremes
Absence of electronic storage eliminates meter data corruption
Reverse connected meter measures consumption correctly
Built-in self test, warning or failure indication on dual colour LED
Electronic pulse output or serial data stream via SLMS port
Withstands 10kV lightning and 1kV DC insulation testing voltages
Tamper proof terminal covers with optional grommets, reduce losses
Pulse output indicator confirms availability of supply when load disconnected
Nominal Voltage (Un) 120V or 230V AC
Operational Frequency Range 54 to 66Hz or 45 to 55Hz
Operational Voltage Range 60 to 180V or 100 to 360V
Over Voltage Withstand 600V AC for 48 hours
DC Voltage Withstand 1000V DC for 1 minute
Impulse Voltage Withstand 10kV differential mode
ESD Withstand 15kV air discharge
Basic Current (Ib) 5 Amps
Maximum Rated Current (Imax) 65 Amps
Operational Current Range 20mA to 90 Amps
Overcurrent Withstand 120 Amps for 48 hours
180 Amps for 1 minute
Fault Current Withstand 5kA for 10mS
Voltage Circuit Burden 0.2 Watts and 4 VA
LED Output Flash Rate 1000 impulses per kWh
Declared Accuracy at 0.1A ±5%
Accuracy Class Class 2
Protection Class Class 2, double insulated
Operating Temperature Storage Temperature -100C to 600C
Storage temperature -250C to 800C
PRODUCT BROCHURE
2012
SECTION D
ELECTRICAL CABLES
PRODUCT BROCHURE
2012
Types of Cables
Building Cables:
Communication and Telecommunication Cables:
Sourced from the most respected manufacturers, there are a wide variety of high quality solutions available designed to meet the demands of industry standards such as RS484, RS 232 and RS 422.
The company's extensive portfolio includes high performance Cat 5 and Cat 6 cables designed to support a frequency range of up to 100 MHz with transmission speeds of up to 1 Gigabit per second.
Rail and Transport
Electricity Transmission Cables:
PRODUCT BROCHURE
2012
PRODUCT DETAILS:
BS125 BS 215 BS 4066
BS 2E21 BS 5308 BS 5467
BS 6004 BS 6007 BS 6121
BS 6141 BS 6195 BS 6231
PRODUCT BROCHURE
2012
BS 6346 BS 6360 BS 6469
BS 6480 BS 6500 BS 6622
BS 6724 BS 6883 BS 60228
BS 638 BS 7211 BS 7629
PRODUCT BROCHURE
2012
BS 7835 BS 7870 BS 7884
BS 7919 BS 6004 BS 6500
BS 6622 CSA 22.23 DIN VDE 250
DIN VDE 262 DIN VDE 266 DIN VDE 271
PRODUCT BROCHURE
2012
DIN VDE 276 DIN VDE 277 DIN VDE 281
EIA RS 232 H03VV-F H05BN4-F
UL 758 H05VV-F H07BN4-F
H07V-K TIA/EIA 568 RS 422
PRODUCT BROCHURE
2012
USES AND SPECIFICATIONS
1. BS 125 Electric conductors, copper and copper-cadmium, for overhead transmission 2. BS 215 Electric conductors, aluminium and steel- cored aluminium 3. BS 4066 Electric cables, tests under fire conditions 4 BS 2 E 21 Pren type electric cables for aircraft. 5. BS 5308 Part 1 Insulated cables, instrumentation, intrinsically safe 6. BS 5308 Part 2 Insulated cables, instrumentation, intrinsically safe 7. BS 5467 Power cables, armoured thermosetting-polymer insulated, for electricity supply 8. BS 6004 Insulated cables PVC insulated, non armoured 9. BS 6007 : 2006 Electric cables. Single core unsheathed heat resisting cables for voltages up to and including
450/750V, for internal wiring 10. BS 6121 Mechanical cable glands 11. BS 6141 Flexible conductors, for high temperature zones; this standard has been withdrawn and replaced
by tables in BS 6004:2000, BS 6007:2000, BS6500:2000 and BS 7919:2001 12. BS 6195 : 2006 Electric cables. Rubber or silicone rubber insulated flexible cables and cords for coil end leads 13. BS 6231:2006 Electric cables. Single core PVC insulated flexible cables of rated voltage 600/1000V for switchgear
and control gear wiring 14. BS 6346 : 1997 Electric cables, PVC insulated, armoured cables for voltages of 600/1000V and 1900/3300V 15. BS 6360 : 1991 Specification for conductors in insulated cables and cords. This standard is obsolete and will be
replaced by BS EN 60228. 16. BS 6469: section 99.1:
1992 Insulating , sheathing materials of electric cables, non electrical tests
17 BS 6480 Specification for impregnated paper- insulated lead or lead alloy sheathed electric cables of rated voltages up to and including 33000V
18. BS 6500:2000 Electric cables. Flexible cords rated up to 300/500V, for use with appliances and equipment intended for domestic, office and similar environments
19. BS 6622:1999 Cables with extruded cross linked polyethylene or ethylene propylene rubber insulation 3.8/6.6kV to 19/33kV
20. BS 6724:1997 600/1000V, 1900/3300V armoured electric cable with thermosetting insulation and low emission smoke, gases
21. BS 6883:1999 Elastomer insulated cables for fixed wiring in ships 22. BS 60228:2005 Conductors of insulated cables 23. BS 638:Part4:1996 Arc welding power sources, equipment and accessories. Specification for welding cables 24. BS 7211:1998 Thermosetting insulated cables, non armoured, with low smoke and gas 25. BS 7629 Part 1 Specification for 300/500V fire resistant electric cable having low emission of smoke and corrosive
gases when affected by fire multicore cables 26. BS 7629 Part 2 Specification for 300/500V fire resistant electric cable having low emission of smoke and corrosive
gases when affected by fire multipair cables 27. BS 7835 Specification for armoured cables with extruded cross-linked polyethylene or ethylene propylene
rubber insulation for rated voltages from 3.8/6.6kV up to 19/33kV having low emission of smoke and corrosive gases when affected by fire
28. BS 7870 LV and MV polymeric insulated cables for use by distribution and generation utilities. General 29. BS 7884:1997 Specification for copper and copper- cadmium stranded conductors for overhead electric traction
and power transmission systems. 30. BS 7919:2001 Electric cables. Flexible cables rated up to 450/750V, for use with appliances and equipment
intended for industrial and similar environments 31. Generally to
BS 6004 Insulated cables, PVC insulated, non armoured
32. Generally to BS 6500
Flexible cables, insulated cords and cables
33. CSA 22.23 No 127 Type TEW
Equipment and Lead Wires
34. CW 1128 Specification CW 1128 for cable polyethylene twin and polyethylene twin - screened 35. DIN VDE 250 Part 1 to
part 819 Cables, wires and flexible cords for power installation
PRODUCT BROCHURE
2012
36. DIN VDE 262 XLPE insulated and PVC sheathed installation cable up to0.6/1kV 37. DIN VDE 266 Part 3 and
4 Halogen free cables with improved characteristics in the case of fire- nominal voltages 6 to 30kV
38. DIN VDE 271 PVC insulated cables rated voltages up to and including 3.6/6(7.2)kV 39. DIN VDE 276 Part 603 Distribution cables of nominal voltages Uo/U 0.6/1kV 40. DIN VDE 276 Part 604 Power cables of nominal voltages Uo/U 0.6/1kV with special fire performance for use in power
stations 41. DIN VDE 276 Part
604/605 Additional test methods
42. DIN VDE 276 Part 620 Distribution cables of nominal voltages Uo/U 3.6kV to 20.8/36kV 43. DIN VDE 277 Airport lighting 44. DIN VDE 281 part 1 to
part 404 PVC cables, wires and flexible cords for power installation
45. DIN VDE 282 Part 1 to Part 808
Rubber cables and flexible cords for power installation, heat resistant silicone rubber insulated cable, halogen free insulated cable, arc welding cable, rubber insulated lift cable, rubber sheathed flexible cables
46. EIA RS 232 TIA/EIA standard for serial transmission between computers and peripheral devices 47. H03VV-F Circular, PVC insulation/PVC sheathed 300/300V, to BS 6500 48. H05BN4-F Single Core, Rubber insulated, HOFR sheathed, 450/750V 49. H05V-K Single core, PVC insulated only, 300/300V 50. H05VV-F PVC insulated and sheathed, 300/500V 51. H07BN4-F Single core, Rubber insulated, HOFR sheathed, 450/750V 52. H07V-K Single core, PVC insulated only, 450/750V, Flexible conductor 53. H07V-R Single core, PVC insulated only, 450/750V, Stranded conductor 54. H07V-R Single core, PVC insulated only, 450/750V, Stranded conductor 55. IEC 60598-1 Luminaries- General requirements and tests 56. RS 422 Electrical characteristics of the balanced voltage digital interface circuit 57. TIA/EIA 568 Commercial Building Telecommunications Wiring Standard Part 1 : General Requirements 58. UL 758 Appliance wiring Material