38
APRIL 2012 DATA&IT, SBU C-UPS, PM/SR PRODUCT PRESENTATION PROTECT D.6000 / D.10000

Transcript of Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC...

Page 1: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

APRIL 2012DATA&IT, SBUC-UPS,PM/SR

PRODUCT PRESENTATIONPROTECT D.6000 / D.10000

Page 2: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

2

CONTENTS

A CLASSIFICATION 3

AVAILIBILTY 8

PRODUCT HIGHLIGHTS 12

SUMMARY 37

B

C

D

Page 3: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

CLASSIFICATION ACC. TO

- AEG΄S UPS PRODUCT PORTFOLIO

- IT΄S APPLICATION ORIENTED USE

- UPS PRODUCT NORM IEC 62040-3

A-CLASSIFICATION

Page 4: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

4

CLASSIFICATION ACC. TOAEG´S UPS PRODUCT PORTFOLIO

CLA

SSIFICATIO

N E

nergy Efficiency S

olutions

”Industrial” UPS

Rectifier + Transokraft30 / 50 / 80 / 120 / 170 [kVA]

3-phase OutputOn-Line / VFI - technology

PROTECT 8.3110/20/30/40/60/80/100/120 [kVA]

1-phase OutputOn-Line / VFI - technology

PROTECT 8.3310/20/30/40/60/80/100/120 [kVA]

3-phase OutputOn-Line / VFI - technology

PROTECT 8.33 „high power” 160 / 220 / 300 / 400 / 500 [kVA]

3-phase OutputOn-Line / VFI - technology

Rectifier + PROTECT 8. INV 110/20/30/40/60 [kVA]

1-phase OutputOn-Line / VFI - technology

Rectifier + PROTECT 8. INV 325/40/60/80/100/120 [kVA]

3-phase OutputOn-Line / VFI - technology

”All-round” UPS

PROTECT 3.3110 / 20 / 30 / 40 / 60 [kVA]

1-phase OutputOn-Line / VFI - technology

PROTECT 3.3310/20/30/40/60/80/100/120 [kVA]

3-phase OutputOn-Line / VFI - technology

PROTECT BLUE.250 / 500 / 750 / 1000 / 1250 [kVA]

3-phase OutputOn-Line / VFI - technology

PROTECT STS100 / 200 / 400 / 600 / 800 / 1200 [A]

3-pole ( 4-pole on request )Static Transfer Switch

PROTECT 3.M 2.020/40/60/80/100/120 [kVA]

3-phase OutputOn-Line modular / VFI - technology

PROTECT 2.33 2.010/15/20/30/40/60/80 [kVA]

3-phase OutputOn-Line / VFI - technology

”Compact” UPS

PROTECT B. / PROTECT B.PRO750 (+B.) / 1000 (+B.) / 1400 / 1800 / 2300 / 3000 [VA]

1-phase OutputLine-Interactive / VI - technology

PROTECT HOME. / PROTECT A.500 / 600 (HOME.) / 700 / 1000 / 1400 [VA]

1-phase OutputVFD (PROTECT HOME.) / VI - technology

PROTECT C.(S) / PROTECT C. R(S)1000 / 2000 / 3000 (+R/+RS) / 6000 / 10000 [VA]

1-phase OutputOn-Line / VFI - technology

PROTECT 1.10000 / 15000 / 20000 [VA]

1-phase OutputOn-Line / VFI - technology

PROTECT D.1000 / 1500 / 2000 / 3000 / 6000 / 10000 [VA]

1-phase OutputOn-Line / VFI - technology

PROTECT 1.Mscalable: 4000 up to 24000 [VA]

1-phase OutputOn-Line modular / VFI - technology

Page 5: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

5

CLASSIFICATION ACC. TOAEG´S COMPACT- UPS PRODUCT PORTFOLIO

CLA

SSIFICATIO

N E

nergy Efficiency S

olutions

0.7 1 2 3 4 6 10 12 168 20Power [ kVA ]

PROTECT 1.

PROTECT C.

PROTECT A.

PROTECT B.

0.5

PROTECT 1.M

1 ph ~ / 1 ph ~

3 ph ~ / 1 ph ~

1.5

PROTECT C.R

PROTECT HOME.

24

Explanations :

PROTECT D.

PROTECT B. PRO

VI technology( line-interactive )

VFI technology( double-conversion )

VFD technology( offline )

Compact UPS

PROTECT B. / PROTECT B.PRO750 (+B.) / 1000 (+B.) / 1400 / 1800 / 2300 / 3000 [VA]

1-phase OutputLine-Interactive / VI - technology

PROTECT Home. / PROTECT A.500 / 600 (HOME.) / 700 / 1000 / 1400 [VA]

1-phase OutputVFD (PROTECT HOME.) / VI - technology

PROTECT C.(S) / PROTECT C.R(S)1000 / 2000 / 3000 (+R/+RS) / 6000 / 10000 [VA]

1-phase OutputOn-Line / VFI - technology

PROTECT 1.10000 / 15000 / 20000 [VA]

1-phase OutputOn-Line / VFI - technology

PROTECT D.1000 / 1500 / 2000 / 3000 / 6000 / 10000 [VA]

1-phase OutputOn-Line / VFI - technology

PROTECT 1.Mscalable: 4000 up to 24000 [VA]

1-phase OutputOn-Line modular / VFI - technology

Page 6: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

6

CLASSIFICATION ACC. TOIT´S APPLICATION ORIENTED USE

CLA

SSIFICATIO

N E

nergy Efficiency S

olutions

PROTECT 1.10 to 20 kVAFor small datacentres,protectionof cash tillsystems,buildingtechnology.

Hom

e, S

oHo

Offi

ce, S

oHo,

IT s

egm

ent

Dat

a C

entre

Indu

stry

Com

pact

UP

SM

ediu

m H

igh

Pow

er U

PS

PROTECT A.500 to 1400 VAProtects PCs, workstationsand phone systems.

PROTECT HOME.600 VAComprehensive protectionfor all Multimedia equipment.

PROTECT C.1000 to 10000 VARack or tower for sensitivenetworks, small computercentres, Intranet and Internetservers.

PROTECT 1.M4 to 24 kVAScaleable, modularhigh-performanceUPS-systemfor theIT sector.

PROTECT 2.33 2.010 to 80 kVAHost computers,file servers,Workstations andcomputer centresas well as complexnetworks inindustrialcompanies.

PROTECT 1.10000 to 20000 VAFor small data centres,protection of cash tillsystems, buildingtechnology.

PROTECT B./B.PRO750 to 3000 VARack or tower for server andnetwork components withsinusoidal output.

PROTECT 3.M 2.020 to 120 kVA (scalelable)Computer centres, Internetnodes, banks &insurancecompanies.

PROTECT D.1000 to 10000 VARack or tower for sensitivenetworks, small computercentres, Intranet and Internetservers.

PROTECT BLUE.250 to 1000 kVABuilding control systems,data centres,internet nodes, banks, suitablefor all criticalapplicationsin this spectrum.

Page 7: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

7

CLASSIFICATION ACC. TOUPS PRODUCT NORM IEC 62040- 3

CLA

SSIFICATIO

N E

nergy Efficiency S

olutions

Voltage Phenomenon Time e.g. IEC UPS Arrester62040-3 solution solution

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

Outage - blackouts

Sags / brownouts

Dynamic overvoltage

Undervoltage

Overvoltage

Transients (Surge)

Frequency variations

Voltage distortion (Burst)

Voltage harmonics

Lightning

> 10 ms

continuous

continuous

< 4 ms

sporadic

periodic

continuous

sporadic

VFDVoltage +

FrequencyDependent

VIVoltage

Independent

VFI

Voltage +Frequency

Independent

Classification 3

Offline

Classification 2

Line-Interactive

Classification 1

(true) Online

real Double-Conversion

Surge- and Over-voltage protection(IEC 60364-5-534)

see as well 10.

Limited protection via UPS

(extended protectionrecommended (10.))

PROT

ECT

D.

Page 8: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

B-Availability

Page 9: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

9

AVAILA

BILITY E

nergy Efficiency S

olutions

AVAILABILITY/ PRODUCT D. EXTENSION

- PROTECT D.1000 / D.1500 / D.2000 / D.3000 (all 2U, always equipped with integr. batteries)

- PROTECT D.1000BP / D.1500BP / D.2030BP(Battery extension, always 2U)

- PROTECT D.6000 (3U)(incl. integr. battery system and manual bypass)

- PROTECT D.6000BP / D.10000BP(battery extension, always 3U)

- PROTECT D.10000 (5U)(incl. integr. battery system and manual bypass)Battery cover can be removed separately

ex s

tock

-ite

ms

are

subj

ectt

opr

iors

ales

-

Page 10: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

10

AVAILA

BILITY E

nergy Efficiency S

olutions

TRANSFER PROCESS IN DETAILMARKET INTRODUCTION

PROTECT C.6000R / PROTECT D.6000 / D.10000

…2011 - 2012 10 1211 01 03 06 07 111005 12

2011

PROTECT C.6000R / PROTECT C.6000RBP

PROTECT D.6000 / D.6000BP / D.10000 / D.10000BP

6 months

e.g. PROTECT D.6000incl. battery system

Parallel operation for PROTECT D. 6k & 10k

2012

02 08 0904

Page 11: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

11

AVAILA

BILITY E

nergy Efficiency S

olutions

TRANSFER PROCESS IN DETAILMARKET INTRODUCTION

PROTECT C.6000R PROTECT C.6000RBP

PROTECT C.R seriesTransfer process starting end of 01 / 2012 >>>

PROTECT C.6000R / C.6000RBP1

PROTECT D.6000 / D.6000BPD.10000 / D.10000 BP

2

Transfer solution starting 08 / 2012 >>>

PROTECT D.6000 / D.6000BPD.10000 / D.10000BP

1

Starting autumn 2012 :Parallel operation PROTECT D.6000 / D.10000

2

Page 12: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

C-PRODUCT HIGHLIGHTS

Page 13: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

13

PERFORMANCE – MORE POWERFUL SERIESPOWER RATING AT PF=0.9LAG. FOR ALL PROTECT D. MODELS

PRO

DU

CT H

IGH

LIGH

TS –PER

FOR

MA

NC

E

6000 VA/ 5400 W 10000 VA/ 9000 W

more power for modern SPS loadswith PFC correction

6000 VA / 4200 W

Power extension to 10kVA

Page 14: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

14

PERFORMANCE – POWER BANDWIDTHABLE TO COVER THE COMPLETE POWER FACTOR SPECTRUM

PRO

DU

CT H

IGH

LIGH

TS –PER

FOR

MA

NC

E

able to handlepure lagging load

able to handlepure leading load

00.90.8 0.90.7 0.8 0.7 0.60.60.5 0.50 0.1 0.2 0.3 0.4 00.4 0.3 0.2 0.1

leading load (pf=... cap.)lagging load (pf =... lag.)

active load (pf =1)

full power

Page 15: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

15

PERFORMANCE – POWER BANDWITHABLE TO OPERATE 100% NON-LINEAR LOAD

PRO

DU

CT H

IGH

LIGH

TS –PER

FOR

MA

NC

E

Cleaner power( ≥0.99 THDi < 5% )

Input voltage (mains)Input current (mains)

UPS output voltageCurrent (UPS load)

Less power pollution Suitable for all kind of loads

Page 16: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

EFFICIENCY

Page 17: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

17

PERFORMANCE – EFFICIENCYSHORT-TERM AMORTIZATION – LESS COOLING

PRO

DU

CT H

IGH

LIGH

TS –PER

FOR

MA

NC

E

6000 VA / 4200 W > 88%

6000 VA / 5400 W 92%

> 96% ECOat the weekend

Consumption at 90% load (3780W)Losses at 8760h/year = 4515 kWh

Consumption at 3780WLosses = 2879 kWh

2063 kWh less lossesSaving/year: ~412 €*

1636 kWh less losses / Saving per year: ~ 327 €*

double-conversion( VFI ) mode

* calculation basicsEUR 0.20 per kWh

Page 18: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

18

PRO

DU

CT H

IGH

LIGH

TS –FO

OTPR

INT

6000 VA / 4200 W 6000 VA / 5400 W

3U

only 3 U height … and manual bypassPROTECT D.6000incl. battery system

FOOTPRINT– LESS RACK SPACE REQUIRED

Page 19: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

19

PRO

DU

CT H

IGH

LIGH

TS –M

AIN

TENA

NC

E

INSTALLATION/ MAINTENANCE

Removable connection unitfor easy connection and most effective maintenance procedure

Using the manual bypass switchautomatically the load will be transferred the bypass mains

Subsidiary distributionfor direct connection of the load, respectively other PDU´s

Outlets with innovative lock mechanismto avoid blackouts by removing the load cable accidentially

e.g. rear view D.6000

Page 20: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

20

PACKAGING

PRO

DU

CT IN

FO –

PAC

KA

GIN

G

ONE package for all componentsof PROTECT D.6000 / D.10000

ONE article-no.to simplify the logistics

Easy handling on siteas each component providesa weight of less than 30kg

Safe shipmentacc. to disconnected batteries

Page 21: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

21

PRO

DU

CT IN

FO –

UN

PAC

KA

GIN

G

UNPACKAGING – E.G. PROTECT D.6000

Page 22: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

22

PRO

DU

CT IN

FO –

SHIPM

ENT

SHIPMENT – PROTECT D.6000

PROTECT D.6000

Main parts UPS unit

6000 VA / 5400 W Connection unit

with subsidiary distributionand integrated manual bypass Battery system

as slide-in module Printed Safety and

Operating Instructionsincl. installation description

Accessories (included) Rail slider kit incl. brackets

for max. post distance of 1200mm Glands ( PG29 - 3pcs.) Output cable ( IEC320-C20 > IEC320-C19) Communication cables ( RS232 & USB) Shutdown- and Management Software

“CompuWatch” incl. fivefold network licence Registration card

for extended warranty of 36months

Page 23: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

23

PRO

DU

CT IN

FO –

SHIPM

ENT

SHIPMENT – PROTECT D.10000

PROTECT D.10000

Main parts UPS unit

10000 VA / 9000 W Connection unit

with subsidiary distributionand integrated manual bypass Battery system

as slide-in modules ( 2 pcs.) Printed Safety and

Operating Instructionsincl. installation description

Accessories (included) Rail slider kit incl. brackets

for max. post distance of 1200mm Glands ( PG36 - 3pcs.) Output cable ( IEC320-C20 > IEC320-C19) Communication cables ( RS232 & USB) Shutdown- and Management Software

“CompuWatch” incl. fivefold network licence Registration card

for extended warranty of 36months

PROTECT D.10000

Page 24: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

24

PRO

DU

CT H

IGH

LIGH

TS –IN

STALLATIO

N

INSTALLATION – E.G. PROTECT D.10000

Single INPUT Dual INPUT

Cable entry eitherfrom the back or the top

Page 25: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

25

PRO

DU

CT IN

FO –

CO

NN

ECTIO

NS

REAR VIEW – CONNECTIONS PROTECT D.6000

2 pcs. IEC320 C13 & 1pc. IEC320 C19with automatic locking mechanism

Maintenance Bypasswith undetachable screws

Terminals insideDual or Single Input

RS232Port

Fuses forsub-distribution

USB Port

Parallelport

Programmable potential-free contact

Communication slot

EmergencyPower Off

Solid screwfor direct earthing

Pre-punched holesGlands can be installedeither on top or on back

GLN & S/N Serial-number also

provided on the display

Intelligentfan speed control

Page 26: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

26

PRO

DU

CT IN

FO –

CO

NN

ECTIO

NS

REAR VIEW – CONNECTIONS PROTECT D.10000

4 pcs.lockable IEC320 C19

Rectifier OutputBypass

Terminals inside

USBPort

Fuses for each pair

of receptacles

RS232Port

RJ11(battery detection)

External battery connector

Parallelport

Programmable potential-free contact

Communicationslot

EmergencyPower Off

Dual or Single Input

Solid screwsfor directearthing

Pre-punchedholes

Glands can be installedeither on topor on back

Glands are partof delivery

GLN & S/N Serial-numberalso providedon the display

Maintenance Bypasswith undetachable screws

Page 27: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

27

PRO

DU

CT IN

FO –

OPER

ATION

UPS OPERATION – LCD DISPLAY

Display for UPS status, Control,Settings, Measurements, Event Log, Identification

Real time clock( synchronized automatically )

Data logger for 127 events

For more details refer to the PROTECT D. presentationin the range from 1 to 3kVA

Graphical LCD display( 128 x 64 pixel )

Multilingual >> 5 languages( EN / DE / FR / ES / RU )

2.8 "Viewing area:59.65 x 39.02 mm

Page 28: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

28

PRO

DU

CT IN

FO –

BATTERY EXTEN

SION

EXTERNAL BATTERY PACKS

PROTECT D.6000 Front connection Automatic detection Process

hot – swappable Connection

with fixed polarity

PROTECT D.10000 Rear connection Automatic detection Process

hot – swappable Connection

with fixed polarity

Page 29: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

29

PRO

DU

CT IN

FO –

AU

TON

OM

Y DATA ( I )

AUTONOMY TIME DATA – PROTECT D.6000

Full load / half loadat pf = 0.9 lag. at pf = 0.7 lag.

with integrated batteries3 / 9.5 5 / 13

with 1 additional battery pack11 / 27 15 / 39

with 2 additional battery packs20 / 46 26 / 67

with 3 additional battery packs30 / 68 38 / 98

with 4 additional battery packs40 / 91 51 / 132

3U

3U

3U

3U

3U

Page 30: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

30

PRO

DU

CT IN

FO –

AU

TON

OM

Y DATA ( II )

AUTONOMY TIME DATA – PROTECT D.10000

PROTECT D.10000BP

PROTECT D.10000BP

PROTECT D.10000BP

PROTECT D.10000BP

PROTECT D.10000

5U

3U

3U

3U

3U

Full load / half loadat pf = 0.9 lag. at pf = 0.7 lag.

with integrated batteries4 / 7.5 5,5 / 10,5

with 1 additional battery pack9 / 18 12 / 25

with 2 additional battery packs15 / 30 20 / 41

with 3 additional battery packs21 / 43 28 / 59

with 4 additional battery packs27 / 57 36 / 78

Page 31: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

31

PRO

DU

CT IN

FO –

AU

TON

OM

Y DATA ( III )

AUTONOMY TIME DATA IN DETAILAT PART LOAD ( PF = 0.9 LAGGING )

PROTECT D. (Rack model)at part load

< < < A u t o n o m y t i m e a t p f = 0.9 l a g g i n g > > >

10% load 25% load 50% load 75% load 100% load

PROTECT D.6000 [ 6 kVA ] = 540 W = 1350 W = 2700 W = 4050 W = 5400 W

with integrated battery system 65 min. 23 min. 9.5 min. 5.5 min. 3 min.

with 1 x PROTECT D.6000BP 182 min. 66 min. 27 min. 16 min. 11 min.

with 2 x PROTECT D.6000BP 315 min. 114 min. 46 min. 28 min. 20 min.

with 3 x PROTECT D.6000BP 461 min. 168 min. 68 min. 41 min. 30 min.

with 4 x PROTECT D.6000BP 616 min. 225 min. 91 min. 54 min. 40 min.

PROTECT D.10000 [ 10 kVA ] = 900 W = 2250 W = 4500 W = 6750 W = 9000 W

with integrated battery system 54 min. 17.5 min. 7.5 min. 5.5 min. 4 min.

with 1 x PROTECT D.10000BP 128 min. 41 min. 18 min. 13 min. 9 min.

with 2 x PROTECT D.10000BP 212 min. 68 min. 30 min. 21 min. 15 min.

with 3 x PROTECT D.10000BP 310 min. 97 min. 43 min. 29 min. 21 min.

with 4 x PROTECT D.10000BP 399 min. 128 min. 57 min. 38 min. 27 min.

Page 32: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

32

PRO

DU

CT IN

FO –

AU

TON

OM

Y DATA ( IV )

AUTONOMY TIME DATA IN DETAILAT PART LOAD ( PF = 0.7 LAGGING )

PROTECT D. (Rack model)at part load

< < < A u t o n o m y t i m e a t p f = 0.7 l a g g i n g > > >

10% load 25% load 50% load 75% load 100% load

PROTECT D.6000 [ 6 kVA ] = 420 W = 1050 W = 2100 W = 3150 W = 4200 W

with integrated battery system 76 min. 34 min. 13 min. 8 min. 5 min.

with 1 x PROTECT D.6000BP 208 min. 91 min. 39 min. 22 min. 15 min.

with 2 x PROTECT D.6000BP 360 min. 156 min. 67 min. 39 min. 26 min.

with 3 x PROTECT D.6000BP 524 min. 226 min. 98 min. 57 min. 38 min.

with 4 x PROTECT D.6000BP 700 min. 301 min. 132 min. 77 min. 51 min.

PROTECT D.10000 [ 10 kVA ] = 700 W = 1750 W = 3500 W = 5250 W = 7000 W

with integrated battery system 74 min. 24 min. 10.5 min. 7.5 min. 5.5 min.

with 1 x PROTECT D.10000BP 175 min. 56 min. 25 min. 17 min. 12 min.

with 2 x PROTECT D.10000BP 290 min. 93 min. 41 min. 28 min. 20 min.

with 3 x PROTECT D.10000BP 413 min. 133 min. 59 min. 39 min. 28 min.

with 4 x PROTECT D.10000BP 545 min. 175 min. 78 min. 51 min. 36 min.

Page 33: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

33

PRO

DU

CT IN

FO –

BATTERY R

EPLAC

EMEN

T

BATTERY REPLACEMENT – PROTECT D.6000

Page 34: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

34

PRO

DU

CT IN

FO –

BATTERY R

EPLAC

EMEN

T

BATTERY REPLACEMENT – PROTECT D.10000

Page 35: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

35

PARALLEL OPERATION (STARTING AUTUMN 2012 )

Parallel operation of 2 units to

achieve active redundancy

increase power

PRO

DU

CT IN

FO –

PAR

ALLEL O

PERATIO

N ( I )

Parallel field / external central bypassplus UPS sub-distributor

Low voltage main distributor( UPS (mains rectifier & bypass))

Page 36: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

36

UPS PARALLEL FIELD ”PDB 20000” AS OPTION

PRO

DU

CT IN

FO –

PAR

ALLEL O

PERATIO

N ( II )Parallel field in 19" rackmount design

Space requirement 3U

Front accessible operating elements

Foolproof manual bypass switchby using additional UPS info

LEDs for clear signallingof current operating mode

Covered control elementsto avoid mistakenly fuse operation

Schematic circuit diagramfor quick and easy guidance

Page 37: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

D-SUMMARY

Page 38: Product presentation PROTECT D.6000 / D - AEG PS · PDF file · 2014-07-18with PFC correction 6000 VA / 4200 W Power extension to 10kVA. 14 ... ABLE TO COVER THE COMPLETE POWER FACTOR

38

CO

NC

LUSIO

N

COMPETITIVENESS – CONCLUSION

More real power( pf of 0.9 lagging, suitable for all kind of critical loads )

Compact size, modern solid look with aluminium front( incl. battery, removable sub-distribution and manual bypass )

Easiest and most flexible installationacc. to mounting (especially weight) and electrical installation

Opportunity to feed the UPS by separate inputs( DUAL or SINGLE input )

Prepared for parallel operationto achieve active redundancy or higher output power

Further on most highlights of the smaller PROTECT D. products( refer to the separate presentation of PROTECT D. 1 to 3 kVA )