product news field module. AS-i Safety at Work Safe signal detection and triggering of the locking mechanism. Connection of fail-safe inductive sensors to EN 954-1 / category 4. 1 safe input for ifm sensors, 1 switching output for actuators. Up to 8 fail-safe inductive sensors can be connected via M12 sockets. Module with standardised EMS interface for AS-i and 24 V. Data transmission on the AS-i bus approved by TÜV and BIA. Protective cover on a laser unit Introduction The ClassicLine Safety at Work module connects fail- safe inductive sensors to AS-interface. Evaluation to the Safety at Work protocol is carried out with one of the four available AS-i safety monitors. The safe data transmission on the AS-i bus has already been approved by TÜV and BIA and is suitable for the transfer of signals up to the highest category 4 to EN 954-1. Powerful LEDs on the front panel indicate switching states of the inputs and outputs, voltage supply and faults at the module, if any. The safe AS-interface input module AC016S is approved for up to category 4 to EN 954-1. ClassicLine Bus systems bus, identification and control systems position sensors and object detection fluid sensors and diagnostic systems

Transcript of product news AS-i Safety at Work field module. · approved by TÜV and BIA. Protective cover on a...

Page 1: product news AS-i Safety at Work field module. · approved by TÜV and BIA. Protective cover on a laser unit Introduction The ClassicLine Safety at Work module connects fail-safe

product news

field module.AS-i Safety at Work

Safe signal detectionand triggeringof the locking mechanism.

Connection of fail-safe inductive sensorsto EN 954-1 / category 4.

1 safe input for ifm sensors,1 switching output for actuators.

Up to 8 fail-safe inductive sensors can beconnected via M12 sockets.

Module with standardised EMS interfacefor AS-i and 24 V.

Data transmission on the AS-i busapproved by TÜV and BIA.

Protective cover on a laser unit

IntroductionThe ClassicLine Safety at Work module connects fail-safe inductive sensors to AS-interface. Evaluation to theSafety at Work protocol is carried out with one of thefour available AS-i safety monitors.The safe data transmission on the AS-i bus has alreadybeen approved by TÜV and BIA and is suitable for thetransfer of signals up to the highest category 4 toEN 954-1.Powerful LEDs on the front panel indicate switchingstates of the inputs and outputs, voltage supply andfaults at the module, if any.The safe AS-interface input module AC016S is approvedfor up to category 4 to EN 954-1.

ClassicLine

Bu

s sy

stem

s

bus,identification

and control systems

positionsensors

and objectdetection

fluid sensorsand diagnostic

systems

Page 2: product news AS-i Safety at Work field module. · approved by TÜV and BIA. Protective cover on a laser unit Introduction The ClassicLine Safety at Work module connects fail-safe

The new input module AC016S allows the connectionof fail-safe inductive sensors of ifm electronic up to cat-egory 4 to EN 954-1. This input module enables the con-nection of up to 8 safety-related inductive sensorswithout integrated AS-i interface to the AS-interfacesystem.In addition to the safe input these units also feature aswitching output for actuators which allows magneticguard locking controlled by AS-i.

Advantages and customer benefits

• Diagnosis and self-testThe safe ClassicLine slave carries out a periodic inter-nal self-test after power on. It is transferred as thesafe state to the master (triggered = code sequence“0000”). After power on and successful function testthe Safety at Work protocol is started (not triggered =cyclical transmission of the code table). The safe inputis now ready for operation.During operation the redundantly designed module ispermanently monitored. The input is monitored forcross faults. In case of a fault a red fault LED indicatesthe fault. In addition an AS-i peripheral fault is gener-ated.

• The Safety at Work systemIn principle, the AS-i safety technology consists of twocomponents: Of one safe input slave for connection ofthe safety devices and the safety monitor as a moni-toring element with positively-driven relays for thesafe switch-off of the drives or actuators. The otherAS-i standard components, like master and currentsupply, remain unchanged.

• AddressingAddressing is done before mounting via the adapterintegrated into the addressing unit or after mountingby means of a module lower part with addressingsocket and an addressing cable with a jack plug.Using the ifm controller e addressing is even moreconvenient. The large graphic display gives the user anoptimum overview.

ApplicationThe fail-safe AS-i ClassicLine module can be used in awide range of different applications. It is suitable wheredecentralised I /O, modular design and simplicity of thesystem are important and a high protection ratingagainst environmental influence is required.

Technical data

Operating voltage (AS-i) [V DC] 26.5...31.6

Housing material PBT (Pocan)

Protection rating IP 67

Operating temperature [°C] -25...55

Error indication LED red

Indication AS-i power LED green

Indication FAULT / ALARM LED red

Indication switching status inputs LED yellow

Total current consumption [mA] ≤ 250

Control category to EN 954-1 4

Safe inputs pcs. 1

Transistor outputs pcs. 1

Current rating per output [mA] 500

AS-i reverse polarity protection •

AS-i profile S-7.B.E

ClassicLine Safety at Work moduleAC016S

Products

Designation Orderno.

ClassicLine safety module 1SI 1DO T AC016S

Safety monitor 1-channel, 1SO R AC001S

Safety monitor 2-channel, 2SO R AC002S

Safety monitor, extended, 2-channel AC004S

Safety monitor, extended, 1-channel AC003S

Serial interface cable SUB-D9 / RJ45 E7001S

AC5003

Configuration software for safety monitor E7020S

FC-E coupling module

T-piece for series connection of fail-safe inductive sensors E11569

90

LEDM12 x1

44

80

Dimensions

Bu

s sy

stem

s

Bus system AS-interface

For further technical data please go to: www.ifm-electronic.com

ifm a

rtic

le n

o. 7

5111

03 ·

Prin

ted

in G

erm

any

on n

on-c

hlor

ine

pape

r. ·

We

rese

rve

the

right

to

mak

e te

chni

cal a

ltera

tions

with

out

prio

r no

tice.

· 10

.200

5

AC016S