Is the SEC Covering Up Wall Street Crimes Rolling Stone Magazine
Product Manual - Long Span III Panel - Wall Covering
Transcript of Product Manual - Long Span III Panel - Wall Covering
Product Manual - Long Span III Panel - Wall Covering
EA37/AB, Outside Closure Installation at EaveRA01/AB, Panel Closure Detail at RakeWC05/AB, Fastener LayoutWC06/AB, Wall Panel EndlapWC08/AB, Pre-Drilling for Fastener LocationsWC20/AB, Typical Corner Detail at PanelsWC21/AB, Corner Flashing Detail (Outside)WC21B/AB, Corner Flashing Detail (Outside) at Open Wall TransitionWC26/AB, Corner Flashing Detail (Inside)WC26B/AB, Corner Flashing Detail (Inside) At Open Wall TransitionWC40/AB, Partially Open Wall Base Trim at Girt With Flush PanelWC41/AB, Partially Open Wall Base Trim at Girt, Panel Extends 1 1/2"WC61/AB, Basic Parts and PiecesWC64/AB, Wall Panel InstallationWC75/AB, Panel BacklappingWC80/AB, Transverse Expansion Joint Detail at SidewallWWC20/AB, Typical Corner Detail at PanelsWWC21/AB, Corner Flashing Detail (Outside)WWC21B/AB, Corner Flashing Detail (Outside) at Open WallWWC26B/AB, Corner Flashing Detail (Inside) At Open Wall TiWWC40/AB, Partially Open Wall Base Trim at Girt With Flush PanelWWC41/AB, Partially Open Wall Base Trim at Girt, Panel Ex
2/17/2021
RODUCT ANUALLONG SPAN III WALL PANEL
P M
Revised 04.01.2018
Outside Closure Installation at Eave
Long Span III Wall
EA37/AB
To Section Index
Download the DWG file by clicking here.
RODUCT ANUALLONG SPAN III WALL PANEL
P M
Revised 8/31/2018
Fastener Layout
Long Span III Wall
WC05/AB
To Section Index
Download the DWG file by clicking here.
RODUCT ANUALLONG SPAN III WALL PANEL
P M
Revised 8/31/2018
Wall Panel Endlap
Architectural III, Architectural "V" Rib or Long Span III Walls
WC06/AB
To Section Index
Download the DWG file by clicking here.
RODUCT ANUALLONG SPAN III WALL PANEL
P M
Issued 9/28/2016
Pre-Drilling for Fastener Locations
Long Span III Wall
WC08/AB
To Section Index
Download the DWG file by clicking here.
RODUCT ANUALLONG SPAN III WALL PANEL
P M
Revised: 11-15-2019 (MR2019.12)
Typical Corner Detail at Panels
Long Span III Wall
WC20/AB
To Section Index
Download the DWG file by clicking here.
DO NOT USE AN AEROSOL TYPE PAINT FOR TOUCH UP.
4. USE TOUCH UP PAINT WITH AN ARTIST TYPE BRUSH.
FASTENERS.
3. PANEL SIDELAPS STITCHED 2'-0" ON CENTER WITH #14 WALL
2. PANELS MUST BE INSTALLED SQUARE WITH BUILDING FRAME.
MAINTAIN 3'-0" COVERAGE PER PANEL.
1. CROWD OR STRETCH PANELS SLIGHTLY AS NECESSARY TO
GENERAL NOTES:
OF PANELS AT SCREW LOCATIONS.FAILURE TO MAINTAIN VERTICAL GIRT FLANGES WILL CAUSE DIMPLING
5. GIRTS ARE TO BE BLOCKED TO MAINTAIN VERTICAL GIRT FLANGES.
6. USE #12X2 FASTENER(S) w/ 6" INSULATION
(GIRTS TOED UP SHOWN, TOED DOWN SIMILAR)
RODUCT ANUALLONG SPAN III WALL PANEL
P M
Revised 8/31/2018
Corner Flashing Detail (Outside)
Long Span III Wall
WC21/AB
To Section Index
Download the DWG file by clicking here.
RODUCT ANUALLONG SPAN III WALL PANEL
P M
Revised 8/31/2018
Corner Flashing Detail (Outside) at Open Wall Transition
Long Span III Wall
WC21B/AB
To Section Index
Download the DWG file by clicking here.
RODUCT ANUALLONG SPAN III WALL PANEL
P M
Revised 8/31/2018
Corner Flashing Detail (Inside)
Long Span III Wall
WC26/AB
To Section Index
Download the DWG file by clicking here.
RODUCT ANUALLONG SPAN III WALL PANEL
P M
Revised 8/31/2018
Corner Flashing Detail (Inside) At Open Wall Transition
Long Span III Wall
WC26B/AB
To Section Index
Download the DWG file by clicking here.
RODUCT ANUALLONG SPAN III WALL PANEL
P M
Revised: 11-15-2019 (MR2019.12)
Partially Open Wall Base Trim at Girt With Flush Panel
Architectural III, Architectural "V" Rib or Long Span III Walls
WC40/AB
To Section Index
Download the DWG file by clicking here.
PARTIALLY OPEN WALL BASE TRIM AT GIRT WITH FLUSH PANEL ARCHITECTURAL III, ARCHITECTURAL "V" RIB OR LONG SPAN III WALLS
WC40
AB
VFF7
FPEC1-10.2
BLIND RIVET
WALL PANEL
WALL MAIN FASTENER(S)#12X1 1/4 (SEE NOTE)1'-0" O.C.
1/8" RIVET
1'-0" O.C.
NOTE: #12X2 FASTENERS w/ 6" INSULATION.
GIRT (TOED UP SHOWN/
TOED DOWN SIMILAR)
RODUCT ANUALLONG SPAN III WALL PANEL
P M
Revised: 11-15-2019 (MR2019.12)
Partially Open Wall Base Trim at Girt, Panel Extends 1 1/2"
Architectural III, Architectural "V" Rib or Long Span III Walls
WC41/AB
To Section Index
Download the DWG file by clicking here.
PARTIALLY OPEN WALL BASE TRIM AT GIRT, PANEL EXTENDS 1 1/2" ARCHITECTURAL III, ARCHITECTURAL "V" RIB OR LONG SPAN III WALLS
WC41
AB
VFF7
FPEC1-10.2
BLIND RIVET
WALL PANEL
1 1/2"
WALL MAIN FASTENER(S)
1'-0" O.C.
1/8 RIVET
1'-0" O.C.
#12X1 1/4 (SEE NOTE)
NOTE: #12X2 FASTENERS w/ 6" INSULATION.
GIRT (TOED UP SHOWN/
TOED DOWN SIMILAR)
RODUCT ANUALLONG SPAN III WALL PANEL
P M
Revised 8/31/2018
Wall Panel Installation
Architectural III, Architectural "V" Rib or Long Span III Walls
WC64/AB
To Section Index
Download the DWG file by clicking here.
RODUCT ANUALLONG SPAN III WALL PANEL
P M
Issued 9/28/2016
Panel Backlapping
Architectural III, Architectural "V" Rib or Long Span III Walls
WC75/AB
To Section Index
Download the DWG file by clicking here.
RODUCT ANUALLONG SPAN III WALL PANEL
P M
Issued 9/28/2016
Transverse Expansion Joint Detail at Sidewall
Long Span III Wall
WC80/AB
To Section Index
Download the DWG file by clicking here.
RODUCT ANUALLONG SPAN III WALL PANEL
P M
Revised 11/15/2019 (MR2019.12)
Typical Corner Detail at Panels
Long Span III Wall
WWC20/AB
To Section Index
Download the DWG file by clicking here.
FBC-1BASE ANGLE CORNER
REQUIRED IF ORDERED
OUTSIDE CLOSURE
GABLE MEMBER
CORNER FLASHING
LONG SPAN III WALL PANELS
TYPICAL CORNER DETAIL AT PANELS
GENERAL NOTES:
BASE ANGLE
AB
WWC20
1'-0 O.C.
1'-0" O.C. AT PANEL RIBS
GIRT
RAKE FLASHING
LONG SPAN III PANELS
WOOD BLOCKING(BY OTHERS)
(SEE NOTE 5)
BA-20
WALL MAIN FASTENER(S)
WALL TRIM FASTENER(S)#14X3/4
#14 X 3/4 WALL TRIM FASTENER(S)
2'-0" O.C. AT PANEL SIDELAPS
EAVE STRUT
#14X3/4 1'-0" O.C. AT PANEL RIBS
WALL TRIM FASTENER(S)
EAVE SUPPORTFLASHING
EAVE CLOSURE FLASHING
RA01
AB
OCA01
DO NOT STEP, SIT OR CLIMB ON WALL
GIRTS OR EAVE STRUTS. FAILURE TO ADHERE
SAFETY PRECAUTION:
TO THIS PRECAUTION MAY RESULT IN ASERIOUS INJURY.
DO NOT USE AN AEROSOL TYPE PAINT FOR TOUCH UP.
4. USE TOUCH UP PAINT WITH AN ARTIST TYPE BRUSH.
FASTENERS.
3. PANEL SIDELAPS STITCHED 2'-0" ON CENTER WITH #14 WALL
2. PANELS MUST BE INSTALLED SQUARE WITH BUILDING FRAME.
MAINTAIN 3'-0" COVERAGE PER PANEL.
1. CROWD OR STRETCH PANELS SLIGHTLY AS NECESSARY TO
OF PANELS AT SCREW LOCATIONS.FAILURE TO MAINTAIN VERTICAL GIRT FLANGES WILL CAUSE DIMPLING
5. GIRTS ARE TO BE BLOCKED TO MAINTAIN VERTICAL GIRT FLANGES.
#12X1 1/4 (SEE NOTE 6)
6. USE #12X2 FASTENER(S) w/ 6" INSULATION
(GIRTS SHOWN TOED UP, TOED DOWN SIMILAR)
RODUCT ANUALLONG SPAN III WALL PANEL
P M
Issued 12/14/2018
Corner Flashing Detail (Outside)
Long Span III Wall
WWC21/AB
To Section Index
Download the DWG file by clicking here.
CORNER FLASHING DETAIL (OUTSIDE)
LONG SPAN III WALLS
WWC21AB
STRUCTURAL LINEGIRT LINE OR
(6) PER FLASHING LAP
BLIND RIVET TYPICAL1/8 RIVET
LONG SPAN III PANEL
CORNER FLASHINGOCA01
1'-0" O.C.
#14X3/4 2'-0" O.C.
WALL TRIM FASTENER(S)
NOTES:
1. FIELD TRIM PANELS AS REQUIRED AT CORNERS.
WALL MAIN FASTENER(S)
#12X1 1/4 (SEE NOTE 2)
2. USE #12X2 FASTENER(S) w/ 6" INSULATION
RODUCT ANUALLONG SPAN III WALL PANEL
P M
Revised 11-15-2019 (MR2019.12)
Partially Open Wall Base Trim at Girt With Flush Panel
Architectural III, Architectural "V" Rib or Long Span III Walls
WWC40/AB
To Section Index
Download the DWG file by clicking here.
PARTIALLY OPEN WALL BASE TRIM AT GIRT WITH FLUSH PANEL ARCHITECTURAL III, ARCHITECTURAL "V" RIB OR LONG SPAN III WALLS
WWC40
AB
FPEC1-10.2
BLIIND RIVET
WALL PANEL
1'-0" O.C.
1/8" RIVET
1'-0" O.C.
DRIP FLASHING
BSD02
WALL MAIN FASTENER(S)
#12X1 1/4 (SEE NOTE)
NOTE:
USE #12X2 FASTENER(S) w/ 6" INSULATION
GIRT (TOED UP SHOWN/
TOED DOWN SIMILAR)
RODUCT ANUALLONG SPAN III WALL PANEL
P M
Revised 11-15-2019 (MR2019.12)
Partially Open Wall Base Trim at Girt, Panel Extends 1 1/2"
Architectural III, Architectural "V" Rib or Long Span III Walls
WWC41/AB
To Section Index
Download the DWG file by clicking here.
PARTIALLY OPEN WALL BASE TRIM AT GIRT, PANEL EXTENDS 1 1/2" ARCHITECTURAL III, ARCHITECTURAL "V" RIB OR LONG SPAN III WALLS
WWC41
AB
FPEC1-10.2
BLIIND RIVET
WALL PANEL
1 1/2"
1'-0" O.C.
1/8 RIVET
1'-0" O.C.
BSD02DRIP FLASHING
WALL MAIN FASTENER(S)
#12X1 1/4 (SEE NOTE)
NOTE:
USE #12X2 FASTENER(S) w/ 6" INSULATION
GIRT (TOED UP SHOWN/