Jumo Instrument Co. Ltd. Jumo Process Control Inc.36035 Fulda, Germany Temple Bank, Riverway 735 Fox ChasePhone (0661) 6003 - 0 Harlow, Essex CM20 2TT Coatesville, PA 19320Fax (0661) 6003 - 607 Phone (01279) 63 55 33 Phone 610 - 380 - 8002Telex 49 701 juf d Fax (01279) 63 52 62 800 - 554 JUMOemail [email protected] Fax 610 - 380 - 8009
Data Sheet 20.2900 Page 1/21
Reference electrodes❑ For use in pH measurement together with a glass electrode (e.g. 2G-2-U)❑ For use in redox measurement together with a metal electrode (e.g. 2M-2-Pt)❑ For use in pH measurement together with an antimony electrode (e.g. 2MP-2-Sb)❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Other fitting lengths (e.g. 160 x 12 mm, 225 x 12 mm) have to be specified in plain text when ordering❑ Customized styles on request❑ With ceramic diaphragm 1mm dia.❑ Ag/AgCl conductive system in cartridge style❑ Gel- or KCl-filled, free of silver ions
Ex-stock standard electrode(can be supplied within 3 working days)
Sales No. Type20/00083865 2B-2-G
Types
2B- Reference electrode
Type of electrode head1- cap N2- cap N with thread Pg 13.5
ElectrolyteG gel-filled operating temperature -5 to +990oC pressure-resistant up to 10 barKCl KCl-filled operating temperature -5 to +100oC unpressurized applications
Type designation for your order:
2B-
Style notes:
2B-2
-G
cartridge
ceramicdiaphragm
Product line 202902
8.98 / 00073065
Data Sheet 20.2900 Page 2/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany
pH glass electrodes❑ For pH measurement together with a reference electrode (e.g. 2B-2-G)❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Other fitting lengths (e.g. 160 x 12 mm, 225 x 12 mm) have to be specified in plain text when ordering❑ Customized styles on request❑ Pressure-resistant up to 10 bar
Ex-stock standard electrode(can be supplied within 3 working days)
Sales No. Type20/00083302 2G-2-U
Types
2G- pH glass electrode
Type of electrode head1-2-
cap Ncap N with thread Pg 13.5
Membrane glassUC
HT
universal glass (standard) operating temp. -5 to +80oC, pH 0-12 (14)glass C(fluoride-resistant up to 500 mg/I HF)
operating temp. 0 to +80oC, pH 0-11
high-temperature glass(also suitable for highly alkaline applications)
operating temp.- 0 to +130oC, pH 1-14
Type designation for your order:
2G-
2G-2
-U
spherical membrane
Style notes:
Product line 202901
8.98 / 00073065
Data Sheet 20.2900 Page 3/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany
Gel-filled pH combination electrodeswith glass shaft❑ Standard electrode for general pH measurement❑ Salt reservoir for longer operational life as standard❑ Versions with PTFE ring diaphragm are particularly suitable for hostile environment
e.g. sewage-treatment plants, oily and heavily contaminated media❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Other fitting lengths (e.g. 160 x 12 mm, 225 x 12 mm) have to be specified in plain text when ordering❑ Integral Pt100 possible (version with cap SMEK threaded Pg 13.5)❑ Customized styles on request❑ Pressure-resistant up to 10 bar❑ Ag/AgCl conductive system in cartridge style❑ Gel filling free of silver ions❑ Special frost-resistant reference electrolyte on low-temperature electrode (3 x ceramic diaphragm is recommended)
Ex- stock standard electrode(can be supplied within 3 working days)
Sales No. Type20/00303348 2GE-1-G-U-120/00300151 2GE-2-G-U-120/00300169 2GE-2-G-HT-120/00321035 2GE-2-G-U-T
Types
2GE- Combination glass electrode
Type of electrode head1- cap N2-9-
cap N threaded Pg 13.5cap SMEK threaded Pg 13.5(on version with integral temperature sensor)
FillingG- gel-filled (filler closed with tubing )
Membrane glassU-HT-
K-C-
TT-
universal glass (standard) operating temp. -5 to +80oC, pH 0-12 (14)high-temperature glass(suitable for highly alkaline applications)
operating temp.- 0 to +90oC, pH 0-14
rounded glass for rounded membrane operating temp. -5 to +80oC, pH 0-12 (14)glass C(fluoride-reistant up to 500mg/I HF)
operating temp. 0 to +80oC, pH 0-11
low-temperature glass operating temp.-30 to +30oC, pH 0-11Diaphragm1 1 x ceramic diaphragm, 1 mm dia.3 3 x ceramic diaphragm, 1 mm dia.T PTFE ring diaphragm
Type designation for your order:
2GE- G-
2GE
-2-G
-U-1
Style notes:
spherical membrane
PTFEring diaphragm
ceramicdiaphragm
rounded membrane
ceramicdiaphragm
spherical membrane
Product line 202903
8.98 / 00073065
Data Sheet 20.2900 Page 4/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany
Gel-filled sealed pH combination electrodeswith glass shaft❑ Standard electrode for general pH measurement❑ Versions with PTFE ring diaphragm are particularly suitable for hostile environment
e.g. sewage-treatment plants, oily and heavily contaminated media.❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Other fitting lengths (e.g. 160 x 12 mm, 225 x 12 mm) have to be specified in plain text when ordering❑ Integral Pt100 possible (version with cap SMEK threaded Pg 13.5)❑ Customized styles on request❑ Pressure-resistant up to 0.5 bar❑ Ag/AgCl conductive system in cartridge style❑ Gel filling free of silver ions
Ex-stock standard electrode(can be supplied within 3 working days)
Sales No. Type20/00300147 2GE-1-GV-U-120/00300148 2GE-2-GV-U-1
Types
2GE- Combination glass electrode
Type of electrode head1- cap N2-9-
cap N threaded Pg 13.5cap SMEK threaded Pg 13.5(only on version with integral temperature sensor)
FillingGV- gel-sealed
Membrane glassU- universal glass (standard) operating temp. -5 to +80oC, pH 0-12 (14)HT- high-temperature glass
(suitable for highly alkaline applications)operating temp. -0 to +90oC, pH 0-14
K- rounded glass (for rounded membrane) operating temp. -5 to +80oC, pH 0-12 (14)C- glass C
(fluoride-resistant up to 500mg /l HF)operating temp.- 0 to +80oC, pH 0-11
Diaphragm1 1 x ceramic diaphragm, 1 mm dia.T PTFE ring diaphragm
Type designation for your order:
2GE- GV-
2GE
-2-G
V-U
-1
Style notes:
spherical membrane
PTFEring diaphragm
ceramicdiaphragm
rounded membrane
ceramicdiaphragm
spherical membrane
Product line 202903
8.98 / 00073065
Data Sheet 20.2900 Page 5/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany
Gel-filled, sealed pH combination electrodeswith plastic shaft❑ Standard electrode for general pH measurement❑ Fracture-resistant shaft material made of high-quality plastic which is resistant to acidic and caustic solutions❑ In 2-chamber version suitable for media which poison the reference system, e.g. heavy metals❑ KCI reservoir as standard, for longer operational life (on Doka version)❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Other fitting lengths (e.g. 160 x 12 mm, 225 x 12 mm) have to be specified in plain text when ordering❑ Integral Pt100 possible (version cap SMEK threaded Pg 13.5)❑ Customized styles on request❑ Pressure-resistant up to 10 bar❑ With glass silk diaphragm ❑ Ag/AgCl conductive system in cartridge style❑ Gel filling free of silver ions
Ex-stock standard electrode(can be supplied within 3 working days)
Sales No. Type20/00303398 2GEP-2-GV-Doka-U-S
Types:
2GEP- Combination glass electrode with plastic shaft
Type of electrode head1- cap N2-9-
cap N threaded Pg 13.5cap SMEK Pg 13.5(only on version with integrated temperatur sensor)
FillingGV- gel-sealedGV-Doka- gel-sealed in 2-chamber version
Membrane glassU- universal glass (standard) operating temp. -5 to +80oC, pH 0-12 (14)HT- high-temperature glass
(suitable for highly alkaline applications)operating temp.- 0 to +80oC, pH 0-14
C- glass C(fluoride-resistant up to 500mg/l HF)
operating temp. -0 to +80oC, pH 0-11
Protective basketS with protective basketO without protective basket
Type designation for your order:
2GEP-
2GE
P-2
-GV
-U-0
spherical membrane
glass silk
Style notes:
diaphragm
without protective basket
Product line 202903
spherical membrane
glass silkdiaphragm
with protective basket
8.98 / 00073065
Data Sheet 20.2900 Page 6/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany
KCl-filled pH combination electrodeswith glass shaft❑ Standard electrode for general pH measurement❑ Version with HT-membrane glass usable up to 130oC❑ Possibility of re-filling liquid KCI via the filler on the shaft,
via the tubing nipple or the pressure head❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Other fitting lengths (e.g. 160 x 12 mm, 225 x 12 mm) have to be specified in plain text when ordering❑ Customized styles on request❑ Pressure-resistant up to 0.5 bar❑ Pressure-resistant up to 10 bar on version 2GE-2-D-... and when suitably pressurized❑ Ag/AgCl conductive system in cartridge style❑ KCl filling free of silver ions
Available accessory:Pressure head Type 2991-0-0025Sales No. 20/00315791
Types
2GE- Combination glass electrode
Type of electrode head1- cap N1-Pg- cap N, nipple and thread Pg 13.5 cemented on2-D- cap N threaded Pg 13.5,
prepared for measurements with Type 2991-0-0025 pressure head (also see page 7)
FillingKCl- KCl filling
Membrane glassU- universal glass (standard) operating temp. -5 to +080oC, pH 0-12 (14)HT- high-temperature glass
(suitable for highly alkaline applications)operating temp.- 0 to +130oC, pH 0-14
K- rounded glass (for rounded membrane) operating temp. -5 to +080oC, pH 0-12 (14)C- glass C
(fluoride-resistant up to 500mg/l HF)operating temp.- 0 to +080oC, pH 0-11
CM- insertion version operating temp. -5 to +080oC, pH 0-12 (14)DS- glass DS (suitable for steam
sterilisation, sterile media)operating temp. 0 to +135oC, pH 1-14
Diaphragm1 1 x ceramic diaphragm, 1 mm dia.2 2 x ceramic diaphragm
(standard on insertion version), 1 mm dia.T PTFE ring diaphragm (for gel filling and glass shaft only)Schliff ground diaphragm
Type designation for your order:
2GE- KCl-
2GE
-1-P
g-K
CL-
HT
-1
roundeddiaphragmring diaphragm
Style notes:
ceramicdiaphragmceramic
PTFEspherical
grounddiaphragm
Product line 202903
spherical
insertionversion
spherical
diaphragmceramic
membrane membrane membrane membrane
8.98 / 00073065
Data Sheet 20.2900 Page 7/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany
sealing cap
Electrodeswith tubing nipple
Electrodes
nipplefor topping up
diaphragmring diaphragm
Style notes:
ceramicdiaphragmceramic
PTFE
with mountedpressure head
thread Pgcemented on
tubeconnection(pressurization,connection of a KClreservoir, etc.)
pressure head
Electrode,preparedforpressure head
spherical rounded membrane spherical membrane
grounddiaphragm
e.g.2GE-2-D-KCl-U-1
spherical membrane
electrolyte
membrane
pressure headType 2991-0-0025
8.98 / 00073065
Data Sheet 20.2900 Page 8/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany
pH combination electrodeswith attached cable connection❑ Standard electrode for general pH measurement❑ Version with CM membrane glass
(insertion electrode) suitable for pH measurementsin semi-solid media (earth, meat, fruit etc.)spear tip 6 mm dia.
❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Other fitting length (e.g. 160 x 12 mm, 225 x 12 mm)
have to be specified in plain text when ordering❑ Customized styles on request
Types
Combination glass electrode2GE- with glass shaft2GEP- with plastic shaft
Type of electrode head3- rubber cap for 3 mm cable diameter, black4- plastic cap for 3mm cable diameter, black
FillingG- gel filling (filler closed with tubing)GV- gel-sealedKCl- KCl filling (filler closed with tubing)
Membrane glassU- universal glass (standard) Einsatz-Temperatur -5...+080oC, pH 0-12 (14)HT- high-temperature glass
(also for highly alkaline applications)Einsatz-Temperatur -5...+130oC, pH 1-14(bei Gel-Füllung -5...+080oC)
K- rounded glass (for rounded membrane) Einsatz-Temperatur -5...+080oC, pH 0-12 (14)C- glass C
(fluoride-resistant up to 500mg /l HF)Einsatz-Temperatur -5...+080oC, pH 0-12 (14)
CM- insertion version Einsatz-Temperatur -5...+080oC, pH 0-12 (14)
Diaphragm1- 1 x ceramic diaphragm, 1 mm dia.
(only with Type 2GE-...)2- 2 x ceramic diaphragm (standard on insertion version)T- PTFE ring diaphragm (only with gel filling and glass shaft)Schliff- ground diaphragmGS- glass silk diaphragm (Type 2GEP-... only)
Cable length. . . . specified in metres
Plug connectionohne no plugBNC with BNC plugDIN with DIN plugLemo with Lemosa plug
Type designation for your order:
spher.membrane
diaphragm
Style notes:
diaphragmceramic
spher.membrane
grounddiaphragm
Product line 202903
2GE
-3-K
Cl-
CM
-2-B
NC
diaphragmceramic
insertionversion
ring diaphragmPTFE
spher.membraneroundedmembrane
spher.membrane
glass silkdiaphragm
+ prot. basket
8.98 / 00073065
Data Sheet 20.2900 Page 9/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany
Metal electrodes for redox measurement❑ In conjunction with a reference electrode (e.g. 2B-2-G) for redox measurement❑ Active platinum element (pin or rounded tip)
for use in e.g. chromate reduction, nitrite oxidation, swimming pool monitoring❑ Active gold element (available only as pin)
for use in e.g. cyanide oxidation❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Other fitting lengths (e.g. 160 x 12 mm, 225 x 12 mm) have to be specified in plain text when ordering❑ Customized styles on request❑ Pressure-resistant up to 10 bar
Types
2M- Metal electrode
Type of electrode head1- cap N2- cap N threaded Pg 13.5
ActiveelementPt platinum pin 1 mm dia. length = 8 mm operating temp. -10 to +130oCPtK platinum tip 5.5 mm dia. operating temp. -10 to +130oCAu gold pin 1 mm dia. length = 8 mm operating temp. -10 to +130oC
Type designation for your order:
2M-
2M-1
-PtK
Au- or Pt-pin
Style notes:
Pt-tip
Product line 202904
8.98 / 00073065
Data Sheet 20.2900 Page 10/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany
Gel-filled metal combination electrodeswith glass shaft for redox measurement❑ Standard electrode with active platinum element for redox measurement
e.g. for chromate reduction, nitrite oxidation, swimming pool monitoring❑ Standard electrode with active gold element for redox measurement
e.g. for cyanide oxidation❑ General laboratory measurements❑ With salt reservoir as standard for longer operational life❑ Versions with PTFE ring diaphragm particularly suitable for hostile environments,
such as sewage-treatment plants, oily and heavily polluted media❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Other fitting lengths (e.g. 160 x 12 mm, 225 x 12 mm) have to be specified in plain text when ordering❑ Customized styles on request❑ Pressure-resistant up to 10 bar (version GV pressure-resistant up to 0.5 bar)❑ Ag/AgCl conductive system in cartridge style❑ Gel filling free of silver ions
Ex-stock standard electrode(can be supplied within 3 working days)
Sales No. Type20/00300394 2ME-1-G-PtK-120/00300397 2ME-2-G-PtK-1
Types
2ME- Metal combination electrode
Type of electrode head1- cap N2- cap N threaded Pg 13.5
FillingG- gel filling (filler closed with tubing)GV- gel filling sealed
ActiveelementPt- platinum pin 1 mm dia. length = 8 mm operating temp. -10 to +90oCPtK- platinum tip 5.5 mm dia. operating temp. -10 to +90oCAu- gold pin 1 mm dia. length = 8 mm operating temp. -10 to +90oC
Diaphragm1 1 x ceramic diaphragm 1 mm dia.T PTFE ring diaphragm (only with gel filling and glass shaft)
Type designation for your order:
2ME-
Styles notes:
2ME
-2-G
-PtK
-1
Au- or Pt-pin Pt-tip
ceramic diaphragmceramic diaphragm
ringdiaphragm
Pt-tip
Product line 202905
PTFE
8.98 / 00073065
Data Sheet 20.2900 Page 11/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany
Gel-filled, sealed metal combination electrodeswith plastic shaft for redox measurement❑ Standard electrode with active platinum element for redox measurement
e.g. for chromate reduction, nitrite oxidation, swimming pool monitoring❑ Standard electrode with active gold element for redox measurement
e.g. for cyanide oxidation❑ Fracture-resistant shaft material of high-quality plastic, resistant against acidic and caustic solutions❑ In 2-chamber version suitable for media which poison the reference system
e.g. heavy metals, sulfur compounds etc.❑ KCI reservoir as standard for longer life (on Doka version)❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Other fitting lengths (e.g. 160 x 12 mm, 225 x 12 mm) have to be specified in plan text when ordering❑ Customized styles on request❑ Pressure-resistant up to 10 bar❑ With glass silk diaphragm❑ Ag/AgCl conductive system in cartridge style❑ Gel filling free of silver ions
Ex-stock standard electrode(can be supplied within 3 working days)
Sales No. Type20/00084009 2MEP-2-GV-Doka-Pt-O20/00084011 2MEP-2-GV-Doka-PtK-O
Types
2MEP- Metal combination electrode with plastic shaft
Type of electrode head1-2-
cap N cap N threaded Pg 13.5
FillingGV- gel-sealedGV-Doka- gel-sealed in 2-chamber version
ActiveelementPt- platinum pin 1 mm dia. length = 8 mm operating temp. -10 to +90oCPtK- platinum tip 5.5 mm dia. operating temp. -10 to +90oCAu- gold pin 1 mm dia. length = 8 mm operating temp. -10 to +90oC
Protective basketO without protective
basket
Type designation for your order:
2MEP- O
Style notes:
2ME
P-2
-GV
-PtK
-0
glass silkdiaphragm
Pt-or Au-pin
glass silkdiaphragm
Pt-tip
Product line 202905
8.98 / 00073065
Data Sheet 20.2900 Page 12/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany
Metal combination electrodeswith attached cable connection❑ Standard electrode for general redox measurement❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Other fitting lengths (e.g. 160 x 12 mm, 225 x 12 mm)
have to be specified in plain text when ordering❑ Customized styles on request
Types
Metal combination electrode2ME- with glass shaft2MEP- with plastic shaft
Type of electrode head3- rubber cap for cable dia. 3 and 5 mm, black
(also 3 mm in white)4- plastic cap for cable dia. 3 and 5 mm, black
FillingG- gel filling (filler closed with tubing)GV- gel-sealedKCl- KCl filling (filler closed with tubing)
ActiveelementPt- platinum pin 1 mm dia. length = 8 mm operating temp. -10 to +90oCPtK- platinum cap 5.5 mm dia. operating temp. -10 to +90oCAu- gold pin 1 mm dia. length= 8 mm operating temp. -10 to +90oC
Diaphragm1- 1 x ceramic diaphragm, 1 mm dia.
(with plastic shaft, diaphragm material: glass fibre)T- PTFE ring diaphragm (only with gel filling and glass shaft)GS- glass silk diaphragm (Type 2MEP-... only)
Cable length. . . . specified in metres
Plug connectionohne without plugBNC with BNC plugDIN with DIN plugLemo mit Lemosa plug
Type designation for your order:
Product line 202905
2ME
P-3
-GV
-PtK
-GS
-BN
C
Styles notes:
glass silkdiaphragm
Pt-or Au-pin
glass silkdiaphragm
Pt-tipAu- or Pt-pin
ceramic
Pt-tip
ceramicringdiaphragm
Pt-tip
PTFE
diaphragm diaphragm
8.98 / 00073065
Data Sheet 20.2900 Page 13/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany
Style notes:
Twin metal electrodesfor redox measurement❑ For use in e.g. titration and amperometric redox potential measurements❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Other fitting lengths (e.g. 160 x 12 mm, 225 x 12 mm) have to be specified in plain text when ordering❑ Customized styles on request❑ Operating temperatures up to 130oC❑ Pressure-resistant up to 10 bar
Types
2MD- Twin metal electrode
Type of electrode head1- cap N2- cap N threaded Pg 13.5
ActiveelementPt-Au platinum pin and gold pin 1 mm dia. length 8 mmPt-Pt platinum pin and
platinum pin1 mm dia. length 8 mm
Type designation for your order:
2MD-
2MD
-2-P
t-A
u
Pt-Au orPt-Pt pin
Product line 202906
8.98 / 00073065
Data Sheet 20.2900 Page 14/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany
Style notes:
Metal electrode for pH measurement (antimony electrode)❑ In conjunction with a reference electrode (e.g. 2B-2-G)
and an electrolyte bridge for pH measurement, e.g. in media containing hydrofluoric acid❑ NOTE: transmitter must have an antimony input
(e.g. 2P1-transmitter to Data Sheet 20.2770 with extra Code /40)❑ Fracture-resistant high-quality plastic shaft material, resistant to acidic and caustic solutions❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Other fitting lengths (e.g. 160 x 12 mm, 225 x 12 mm) have to be specified in plain text when ordering❑ Customized styles on request❑ Pressure-resistant up to 10 bar
Types
2MP- Metal electrode for pH measurement with plastic shaft
Type of electrode head2- cap N threaded Pg 13.5
ActiveelementSb antimony operating temp. -10 to +80oC
Type designation for your order:
2MP- 2- Sb
2MP
-2-S
b
antimonycylinder
Product line 202904
8.98 / 00073065
Data Sheet 20.2900 Page 15/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany
Diaphragm tubes❑ For constructing an electrolyte bridge❑ Diaphragm tubes are used in conjuction with a pH glass electrode in a suitable fitting
(e.g. 2TA-PP-63 to Data Sheet 20.2810) for pH measurement in critical media.They form the diaphragm of a reference electrode in the measurement medium which is inside a separate vessel(e.g. KCl reservoir). This prevents the poisoning of the reference system.In addition, the blocking of the diaphragm (due to the larger surface) is delayed in time.
❑ Applications: emulsions, varnish, paint, photochemicals, liquids which poison the reference system,media containing sulfide, part-aqueous and non-aqueous media miscible or immiscible in water.
❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Customized styles on request.❑ Pressure-resistant to 6 bar when using a pressure-resistant KCl reservoir❑ With PTFE diaphragm 5 mm dia.❑ Supplied together with 3 spare PTFE diaphragms❑ With tubing clamp fitting
for connecting a connection tube of 6 x 1.5 mm cross-section to the KCl reservoir
Available accessory
Sales No.20/00304567 10 spare PTFE diaphragms
Types
2908- Diaphragm tubes
Shaft material16 PP temperature -10 to +080oC26 PVDF temperature -10 to +135oC
Type designation for your order:
2908-
2908
-16
connecting cablee.g. 2992-2(5)-0
immersionfitting2TA-PP-63-3/52
transmitter/controllere.g. 262501(Data Sheet 20.2501) e.g.
liquidKClfillingKCl
reservoir
diaphragm tubee.g. 2908-16
ref.electrodee.g. 2B-2-G
e.g. glass,metal orantimonyelectrode
connecting cablee.g. 2992-2(5)-0
transmitter/controllere.g. 262501(Data Sheet 20.2501)
pH coaxial cablee.g. 2992-2(5)-0
diaphragm tubee.g. 2908-16
flow-through fitting2DA-G½-PP(Data Sheet 20.2810)
KCI
(for wallmounting)
e.g.liquidKClfilling
ref.electrodee.g. 2B-2-G
tubing
reservoir
Construction example: Flow-through measurement Construction example: Measurement in vessel
Product line 202908
glass electrodee.g. 2G-2-HT(or antimony electrode)
8.98 / 00073065
Data Sheet 20.2900 Page 16/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany
Glass conductivity cells❑ For conductivy measurements in acqueous solutions❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Other fitting lengths (e.g. 160 x 12 mm, 225 x 12 mm) have to be specified in plain text when ordering❑ Customized styles on request❑ Cell constant: K = 1 +/- 10%❑ Integral Pt100 possible (version with cap SMEK threaded Pg 13.5)❑ Pressure-resistant to 10 bar
Types
Ex-stock standard electrode(can be supplied within 3 working days)
Sales No. Type20/00303396 2LF-2-Pt
2LF- Conductivity cell
Type of electrode head1- cap N2-9-
cap N threaded Pg 13.5cap SMEK threaded Pg 13.5(only on version with integrated Pt100)
ActiveelementPt platinum platinised operating temp. -10 to +160oC max. range 0—100mS/cmPtU platinum unplatinised operating temp. -10 to +160oC max. range 0—001mS/cm
Type designation for your order:
2LF-
2LF
-2-P
t
Product line 202907
8.98 / 00073065
Data Sheet 20.2900 Page 17/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany
Compensation thermometers❑ For temperature measurement and automatic temperature compensation in pH and conductivity measurement❑ Standard dimensions 120 x 12 mm (DIN 19 263)❑ Other fitting lengths (e.g. 160 x 12 mm, 225 x 12 mm) have to be specified in plain text when ordering❑ Sensor to DIN 43 760 Class B (Pt100)❑ Pressure-resistant to 10 bar❑ Time constant: T0.5 = 0.8sec; T0.9 = 4sec (Pt100)❑ Customized styles on request❑ Operating temperature -10 to +135oC
Ex-stock standard electrode(can be supplied within 3 working days)
Sales No. Type20/00300443 2K-2
2K- Compensation thermometer
Type of electrode head01 cap N; Pt10002 cap N threaded Pg 13.5; Pt10011 cap N; Pt100021 cap N threaded Pg 13.5; Pt100003 twin Pt100; attached cable 3 m; Pg 13.5 cemented on
Type designation for your order:
2K-
2K-2
attached cableL = 3m
Type 2K-3
Type L Ø
2K-115 4.5-0.5
2K-2
2K-1124 2.8-0.5
2K-21
2K-3 22 4.5-0.5
Product line 202920
8.98 / 00073065
Data Sheet 20.2900 Page 18/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany
Connection cables and plugs for electrodes
Ex-stock standard cables(can be supplied within 3 working days)
Sales No. Type20/00082672 2992-2(3)-020/00082673 2992-2(5)-020/00082674 2992-2(8)-020/00085976 2992-2(100)-0
Instrument plug(can be supplied within 3 working days)
Sales No. Type20/00058082 2990-00-1 plug to DIN 19 262 for 5 mm cable dia.20/00058327 2990-00-21 BNC plug, 3 mm cable dia.20/00059253 2990-00-22 BNC plug, 5 mm cable dia.20/00064222 2990-00-23 BNC angle plug, 5 mm cable dia.20/00082463 2990-00-3 banana plug, red20/00082464 2990-00-3 banana plug, black20/00061202 2990-00-4 plug N, 5 mm20/00057350 2991-00-0 cable socket N, 5 mm
For pH / redox and conductivity measurementCable end 12990- no plug connection2992- cable socket Type N, rotating2994- cable socket Type SMEK
Cable type01 low-noise coaxial cable diameter: 3 mm, black temperature -25 to +170oC02 low-noise coaxial cable diameter: 5 mm, black temperature -25 to +170oC03 low-noise coaxial cable diameter: 3 mm, black temperature -20 to +130oC04 low-noise coaxial cable diameter: 5 mm, black temperature -20 to +130oC05 stranded wire temperature -20 to +170oC06 stranded wire temperature -50 to +180oC07 low-noise coaxial cable 2 x copper screen (triax cable)
diameter: 5 mm, black temperature -25 to +170oC08 special cable, 2-core, screened (for conductivity)
diameter: 5 mm, grey temperature -05 to +180oC09 special cable, 4-core, screened (for conductivity)
diameter: 5 mm, grey temperature -05 to +180oC10 coaxial cable (SMEK) + 3 stranded wires and screen
diameter: 5.5 mm, black temperature -05 to +180oC
Cable length( . . . ) specify cable length in metres (e.g. 1 = 1 m cable)
Cable end 2-00 no plug connection-01 plug to DIN 19 262-21 BNC plug for 3 mm cable dia.-22 BNC plug for 5 mm cable dia.-23 BNC angle plug for 5 mm cable dia.-03 banana plug-04 plug N for 5 mm cable dia.-06 AMP plug 6.3 mm-07 5-pole diode plug-08 angle connector for 2EL6- (for cables 8 and 9 only)-09 Lemosa plug for 3 mm cable dia.-13 Shieldkon connector with 2AMP plug 6.3 mm
(for 5 mm coaxial cable dia. only)-14 Cinch plug
Type designation for your order:
( . . . )
2992-2(...)-0
Sta
ndar
d c
able
pH
/red
ox
Product line 202990
8.98 / 00073065
Data Sheet 20.2900 Page 19/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany
1- cap N
Type of electrode head
2- cap N threaded Pg13.5
3- attached cable with rubber cap
4- attached cable with plastic cap
9- SMEK cap (multi-pole connector))
(compatible with most other caps S8 or GSA)
(compatible with most other caps e.g. S7)
with Pg13.5 thread
Material Noryl
Material Perbunan
Electrodeconnectionheads
Connection cables and plugs for electrodes
no plug connection -6 AMP plug6.3 mm-0
-1 -75-polediode plug
-21
-22
-8angle plugfor 2EL6-(for cables 8 and 9 only)
-23-9 Lemosa plug
for 3 mmcable dia.
-3
-13Banana plug
-4 -14Plug N for5 mm cable dia.
Cinch plug
Cable socket Type N, 2992-..., rotating (can be fitted in factory only)
instrument plug to
BNC plug for
BNC plug for
3 mm cable dia.
5 mm cable dia.
BNC angle plug for5 mm cable dia.
Shieldkonconnector with AMP plug 6.3mm(for 5 mm coaxial cable dia. only)
DIN 19 262
8.98 / 00073065
Data Sheet 20.2900 Page 20/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany
Buffer solutions to DIN 19 267❑ Technical buffer solutions to DIN 19 267 are used for calibrating pH electrodes
and have proved very successful, particularly for use in industry and industrial laboratories,because they are relatively unaffected by dilution (high buffering capacity).
❑ The effect of the temperature on the pH values of the buffer solution is shown in the tableon the bottle label.The accuracy is ± 0.02 pH units
❑ The buffer solutions indicate the batch no. and the max. recommended use-by date.❑ The bottle tops are coloured, for identification.
Sales No. Description20/00309747 250 ml buffer solution pH 03.07 to DIN 19267 at 20oC20/00344977 250 ml buffer solution pH 04.00 to DIN 19267 at 20oC20/00301070 250 ml buffer solution pH 04.65 to DIN 19267 at 20oC20/00301071 250 ml buffer solution pH 06.80 to DIN 19267 at 20oC20/00338371 250 ml buffer solution pH 07.00 to DIN 19267 at 20oC20/00301072 250 ml buffer solution pH 09.27 to DIN 19267 at 20oC20/00345027 250 ml buffer solution pH 10.00 to DIN 19267 at 20oC
20/00301073 250 ml redox-potential test solution +468mV (at 25oC)
Minimum ordering quantity: 5 units
Cleaners
Sales No. Description20/00307586 250 ml diaphragm cleaner (thiourea solution)20/00307114 250 ml electrode cleaner (pepsin hydrochloric acid solution, protein remover)
Minimum ordering quantity: 5 units
Auxiliary electrolytes
Sales No. Description20/00306215 250 ml 3-molar KCl solution without AgCl (free of silver ions)20/00307585 250 ml 3-molar KCl solution with AgCl (for electrodes with wire conductor in the reference system)
Minimum ordering quantity: 5 units
Conductivity test-solutions
Sales No. Description20/00346056 250 ml KCl 0.01 mol/l001.41 mS/cm20/00346058 250 ml KCl 0.10 mol/l012.88 mS/cm20/00346060 250 ml KCl 1.00 mol/l111.80 mS/cm
Minimum ordering quantity: 5 units
Product line 202950
8.98 / 00073065
Data Sheet 20.2900 Page 21/21M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany
Simulators❑ Simulators are connected to the transmitter in place of an electrode or measuring cell,
to test connection cables and/or transmitters/controllers (installation test, commissioning etc).❑ Simulation of conductive 2-electrode measuring cells (2H-SLF-1).❑ 2 temperatures, switchable to check temperature compensation (2H-SLF-1).
pH simulatorType 2H-SpH-1Range0—14pH,with selector switch in 1pH stepsOutput signal+414mV to 0 to -414mV,in 59mV steps,corresponding to 0—14pHCalibration accuracy±1% of selected pH valueReference temperature25oCOutput resistance1kOhm (direct) or 1000MOhm (1000M),depending on switch positionSupply 9V block battery (included in delivery)integrated battery check
Conductivity simulator (conductive)Type 2H-SLF-1
Simulation rangewith cell constant C =0.01 to 10.0:conductivity in steps from 2mS/cm to800mS/cm (switchable, see table)
Possible simulations
R / C 0.01 0.1 1.0 3.0 10.0
12.5 V 800 mS 8 mS 80 mS 240 mS 800 mS
25 V 400 mS 4 mS 40 mS 120 mS 400 mS
50 V 200 mS 2 mS 20 mS 60 mS 200 mS
125 V 80 mS 800 mS 8 mS 24 mS 80 mS
250 V 40 mS 400 mS 4 mS 12 mS 40 mS
500 V 20 mS 200 mS 2 mS 6 mS 20 mS
1200 V 8 mS 80 mS 800 mS 2,4 mS 8 mS
2500 V 4 mS 40 mS 400 mS 1,2 mS 4 mS
5000 V 2 mS 20 mS 200 mS 600 mS 2 mS
12.5 kV 800 nS 8 mS 80 mS 240 mS 800 mS
25 kV 400 nS 4 mS 40 mS 120 mS 400 mS
50 kV 200 nS 2 mS 20 mS 60 mS 200 mS
125 kV 80 nS 800 nS 8 mS 24 mS 80 mS
250 kV 40 nS 400 nS 4 mS 12 mS 40 mS
• V 0 0 0 0 0
1000MOhm circuitto check installed pH connection cables for faultsConnectionBNC socket and socket for separate reference electrodePermitted ambient temperature range0 to 50oCCasealuminiumSize70 x 120 x 45 mm
Available connection cablesSales No. Description20/00082906 22-2(1,1)-22,
adapter cable (Fig. 2)BNC/BNC, length 1.1 m
20/00082908 22-2(1,1)-4,adapter cable (Fig. 1)BNC/N plug, length 1.1 m
Calibration accuracy±1% of selected resistancePt100 simulation:25 °C and 75 °C ±1 °Cin 2- wire and 3-wire circuitPermitted ambient temperature0 to 50 °CCasealuminiumSize70 x 120 x 45 mmConnection5-pole diode socket
Available connection cablesSales No. Description20/00082901 7-9(1,1)-0
adapter cable (Fig. 4)diode plug/bare tailslength 1.10 m
20/00082902 7-9(1,1)-6adapter cable (Fig. 3)diode plug/AMP plug6.3 mm, length 1.10 m
(Fig. 1) (Fig. 2)
(Fig. 3) (Fig. 4)
Product line 202711