Strength in Technology
Product Guide 2009
www.fortis-technologies.com Tel: +44 151 336 2266
Fortis PhilosophyHere at Fortis Technologies we take pride in understanding the needs of our customers, levels of technical service are of the highest standard and all of our products are developed in close consultation with customers to ensure that their needs are met.We believe in making method development as simple as possible, so our innovative phase chemistries offer the ability for resolution, efficiency, speed and sensitivity; all of the variables that are needed in today’s high speed evolving world.
If you have any questions please feel free to contact me on : [email protected]
Mark Woodruff Director
Table of Contents2.1µm Fortis C18™ 3-4
2.1µm Fortis Phenyl™ 5
2.1µm Fortis C8™ 6
2.1µm Fortis Cyano™ 7
2.5µm Fortis C18™ 8
Method Development Options 9-10
Fortis C18™ 11-14
Fortis Phenyl™ 15-16
Fortis H2o™ 17
Fortis C8™ 18
Fortis Cyano™ 19
Fortis HILIC™ 20
Fortis Pace™ 21-22
Fortis Prep™ Options 23
Guards and Filters 24
QC, Reproducibility 25
Applications 26-31
www.fortis-technologies.com Tel: +44 151 336 2266
NewProducts
2.1µm Fortis™
Fortis C18™
Fortis Phenyl™
New
Pro
duct
s
2
– Ideal for Ultra High Pressure LC (UHPLC)- Available C18, Di-phenyl, C8, Cyano– Operate to 15,000psi– Fully Scalable analytical to prep
– Superior Peak Shapes- Low, Mid and High pH 1-12– Based upon Ultra Pure Silica– Fully Scalable
– Unique di-phenyl selectivity- Separate Positional Isomers– Aromatic retention and selectivity– Enhanced Polar Retention
Fortis C18pH12pH6pH1
www.fortis-technologies.com Tel: +44 151 336 2266
2.1µm Fortis C18 (2)™
– High Efficiency– Robust Particles– Operate to 15,000psi– Fully Scalable to analytical and prep size
Fortis 2.1µm particles are designed to provide characteristics, which will aid in increased productivity within ultra high pressure chromatography (UHPLC). Designed to be robust, reproducible and fully scalable.Fortis 2.1µm particles will operate both on traditional LC systems, providing increased efficiency, and also on the latest UHPLC systems.
Increased Efficiency
Scalability and Sensitivity
Critically important to the analyst is the ability to have a fully scalable separation. Fortis C18 can be scaled from 2.1µm all the way through analytical 3 and 5µm particles to prep size without any change in retention profile.
By moving from a 3µm particle size to 2.1µm Fortis C18 sensitivity can be increased. In this example peak height goes up by over 27%
2.1µm Fortis C18 provides increased efficiency over 3µm and 5µm particles. This gives the opportunity to increase resolution or speed of analysis.
A wider linear flow range means that more resolution and peak capacity can be achieved for a given separation. By staying above 2µm particle size, Fortis 2.1µm C18 ensures pressure is reduced whilst no loss in efficiency is seen.
– Lower back pressure– Higher Efficiency– Greater Resolution– Increased Sensitivity
Minutes0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
90
100
110
0
100
200
300
400
0.32
51.
3913
584
0.58
51.
2044
615
0.86
51.
0960
717
1.52
00.
9485
516
2.24
30.
9388
708 5µm Fortis C18
2.1µm Fortis C18
3µm Fortis C18
N = 180,564
N = 130,191
N = 88,708
- All columns 50x2.1mm
2.1µm Fortis C18
3µm Fortis C18
Diode ArrayRange: 4.631e+1
Minutes 4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 20.0 22.0
Diode ArrayRange: 3.628e+1
4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 20.0 22.0
Minutes
3
Fortis 2.1µm
www.fortis-technologies.com Tel: +44 151 336 2266
Method Development
Increase Speed
Greater speed can be achieved by moving to smaller particles, whilst still obtaining full baseline resolution.
2.1µm Fortis C18 will operate at higher linear flow rates whilst providing lower backpressure than sub 2µm particles.
To move to smaller particles and smaller columns, without affecting selectivity, use the scaling equations to optimise your UHPLC parameters: e-mail us for the spreadsheet,[email protected]
0
1.23
4438
31.
45
2.64
9136
11.
15
4.03
8756
51.
09
7.26
9225
01.
03
10.9
987
249
1.00
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
3.0x2.1mm 2.1µm
Minutes 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0
0.9ml/min
3.0x2.1mm 2.1µm 0.3ml/min
150x4.6mm 5µm 1.0ml/min
Increase Resolution
Greater resolution can be achieved by maintaining the column length and diameter but moving to a smaller particle size.
2.1µm Fortis C18 will provide very high efficiency and therefore peak capacity and resolution if used with longer column lengths.Columns can be coupled in series to provide extreme resolution capability
Minutes 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0
Minutes0 1 2 3 4 5 6 7 8 9 10
0 1 2 3 4 5 6 7 8 9 10
Increase ResolutionIncrease Resolution
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0Minutes
Rs - 2.14
Rs - 2.58
100x4.6mm 5µm 1.2ml/min
100x2.1mm 2.1µm 0.2ml/min1. Cefadroxil2. Cefachlor3. Cefalexin4. Cefradine
2.1µm Fortis C18 (2) Column Length
30 50 100 150
2.1 F28-020202 F28-020302 F28-020502 F28-020702
Column Diameter 3.0 F28-030202 F28-030302 F28-030502 -
4.6 F28-050202 F28-050302 - -
4
Forti
s 2.1
µm
www.fortis-technologies.com Tel: +44 151 336 2266
2.1µm Fortis Phenyl– High Efficiency– Robust Particles– Operate to 15,000psi– Fully Scalable to analytical and prep size
Fortis 2.1µm particles are designed to provide characteristics which will aid in increased productivity within ultra high pressure chromatography (UHPLC). Designed to be robust, reproducible and fully scalable.Fortis 2.1µm particles will operate both on traditional LC systems, providing increased efficiency, and also on the latest UHPLC systems.
2.1µm Fortis Phenyl(2) Column Length
30 50 100 150
2.1 F2PH-020202 F2PH-020302 F2PH-020502 F2PH-020702
Column Diameter 3.0 F2PH-030202 F2PH-030302 F2PH-030502 -
4.6 F2PH-050202 F2PH-050302 - -
2.1µm Fortis Phenyl™
– High Efficiency and Alternative Selectivity– Unique di-phenyl Chemistry– Operate to 15,000psi– Fully Scalable to analytical and prep size
Providing an alternate selectivity to traditional C18 and C8 chemistries, Fortis Phenyl’s unique di-phenyl structure allows ease of separation. Now the high efficiency of small particles can be combined with selectivity to ensure that resolution is optimised in ultra high pressure chromatography (UHPLC).Fortis 2.1µm particles will operate both on traditional LC systems, providing increased efficiency, and also on the latest UHPLC systems.
5
Fortis 2.1µm
Alternative Selectivity - High Efficiency
Column: Fortis Phenyl 50x2.1mm 2.1µ
p/n: F2PH-020302
Mobile Phase: 80:20 H2O : ACN + 0.1% Formic acid
Flow: 0.8ml/min
Temp: 25°C
Wavelength: 254nm
1. Gliclazide
Particularly adept at separating closely related species Fortis Phenyl is also able to provide retention and separation of many species type whether polar or non-polar.
Where alternate selectivity is required from C18 and C8 then Fortis Phenyl is the key choice.
– Higher Efficiencies– Greater Reproducibility– Resolution enhanced
Minutes0 1 2 3 4 5 6
0
100
200
300
400
0
100
200
300
400
0.3
82
1.4
42
16
2
0.6
85
2.0
70
0.8
43
5.1
91
44
75
9
1.6
75
1.4
96
07
30
To learn more about the unique structure and separating power of Fortis Phenyl turn to page 15.
Fortis Phenyl page 15
Anti-Diabetic
www.fortis-technologies.com Tel: +44 151 336 2266
2.1µm Fortis C8– High Efficiency– Robust Particles– Operate to 15,000psi– Fully Scalable to analytical and prep size
Fortis 2.1µm particles are designed to provide characteristics which will aid in increased productivity within ultra high pressure chromatography (UHPLC). Designed to be robust, reproducible and fully scalable.Fortis 2.1µm particles will operate both on traditional LC systems, providing increased efficiency, and also on the latest UHPLC systems.
2.1µm Fortis C8(2) Column Length
30 50 100 150
2.1 F208-020202 F208-020302 F208-020502 F208-020702
Column Diameter 3.0 F208-030202 F208-030302 F208-030502 -
4.6 F208-050202 F208-050302 - -
2.1µm Fortis C8™
– High Efficiency– Robust Particles– Operate to 15,000psi– Fully Scalable to analytical and prep size
Fortis C8 2.1µm particles will provide an advantage where the hydrophobicity of a C18 is not required. C8 is also often used as the first choice in method development. Fortis C8 2.1µm particles are designed to provide characteristics which will aid in increased productivity within ultra high pressure chromatography (UHPLC). Designed to be robust, reproducible and fully scalable.
6
Forti
s 2.1
µm
Hydrophobicity - High Efficiency
Column: Fortis C8 50x2.1mm 2.1µ
p/n: F208-020302
Mobile Phase: A - H2O + 0.1% Formic acid B - ACN + 0.1% Formic acid
Gradient: 10 - 90% in 15min
Flow: 0.4ml/min
Temp: 20°C
Wavelength: 254nm
1. Telmisartan
Whatever the compound functionality Fortis C8 provides excellent performance. The high bonding density of C8 ligands can also provide resolving power different to that of C18 ligands.
Hydrophobicity is reduced from that of a C18 ligand, allowing steroids and other lipophilic species to be analysed more quickly.
– Higher Efficiencies– Greater Reproducibility– Reduced hydrophobicity over C18
Minutes0 2 4 6 8 10 12 14
0
200
400
600
800
1000
0
200
400
600
800
1000
1.7
17
1.5
83
95
77
2.5
47
0.5
61
21
10
4
2.7
10
1.1
52
44
35
5
4.3
03
1.5
91
31
17
10
Fortis Phenyl page 15
Hypertension
www.fortis-technologies.com Tel: +44 151 336 2266
2.1µm Fortis Cyano™
– High Efficiency– Robust Particles– Operate to 15,000psi– Fully Scalable to analytical and prep size
Fortis Cyano 2.1µm particles are designed to provide alternative selectivity. Along with the other functionalities available on the Fortis 2.1µm particles this provides selectivity as well as increased efficiency for UHPLC analysis. Designed to be robust, reproducible and fully scalable, Fortis Cyano can be operated in normal phase as well reverse phase conditions.
2.1µm Fortis Cyano(2) Column Length
30 50 100 150
2.1 F2CN-020202 F2CN-020302 F2CN-020502 F2CN-020702
Column Diameter 3.0 F2CN-030202 F2CN-030302 F2CN-030502 -
4.6 F2CN-050202 F2CN-050302 - -
7
Fortis 2.1µm
Alternative Selectivity - High Efficiency
Column: Fortis Cyano 50x2.1mm 2.1µ
p/n: F2CN-020302
Mobile Phase: Heptane : THF : MeOH 90:5:5
Flow: 1ml/minTemp: 25°C
Wavelength: 254nm
1. Progesterone
2. 17αHydroxyprogesterone
3. 11αHydroxyprogesterone
4. Hydroxy-21-acetate
5. Cortisone
6. Prednisone
7. Prednisolone
Fortis Cyano works for all types of compounds either in normal phase or reversed phase solvents. Peak shapes and efficiency will be of the highest order.
Normal phase conditions will allow the retention of very polar analytes.
– Higher Efficiencies– Greater Reproducibility– Resolution enhanced
Minutes0 1 2 3 4 5 6
120
140
160
180
200
120
140
160
180
200
To learn more about the separating power of Fortis Cyano turn to page 19.
Fortis Cyano page 19
Steroids
www.fortis-technologies.com Tel: +44 151 336 2266
2.5µm Fortis C18 Column Length
30 50 100 150
2.1 F18-020202 F18-020302 F18-020502 F18-020702
Column Diameter 3.0 F18-030202 F18-030302 F18-030502 F18-030702
4.6 F18-050202 F18-050302 F18-050502 F18-050702
2.5µm Fortis C18™
– Over 20% more efficiency than 3µm– Lower backpressure than UHPLC columns– Operate in 400bar or 1000bar systems– Fully Scalable to analytical and prep size
Fortis 2.5µm particles are designed to be the next step in improving both resolution and speed. Allowing the analyst to move towards ultra high pressure chromatography (UHPLC) whilst still operating on traditional 400bar LC systems. Combined with the companies innovative PACE™ column design, 2.5µm particles offer speed and efficiency without compromising loadability and scalability. The optimised C18 bonding maintains the phases ability to be stable from pH 1-12.
8
Forti
s 2.5
µm
Optimised Resolution
Column: Fortis C18 100x4.6mm 2.5µ
p/n: F18-050502
Mobile Phase: A - H2O + 0.1% Formic acid B - ACN + 0.1% Formic acid
Gradient: 25 - 40% in 10min
Flow: 1ml/min
Temp: 20°C
Wavelength: 254nm
1. Protriptyline
2. Nortriptyline
3. Amitriptyline
4. Trimipramine
Resolution of closely related species can be achieved by the use of 2.5µm particles and the optimised peak shapes afforded by Fortis C18 stationary phase.Basic, Acidic and Neutral analyte performance is first class across the pH spectrum.
– Higher Efficiencies– Greater Reproducibility– Resolution enhanced
Minutes0 1 2 3 4 5 6 7 8 9 10
Fortis Cyano page 19
To learn more about the stability and peak shapes of Fortis C18 turn to page 11.
Fortis C18 page 11
1.0e6
1.5e6
2.0e6
2.5e6
3.0e6
3.5e6
4.0e6
4.5e6
5.0e6
5.5e6
0.0
Tricyclic antidepressants
www.fortis-technologies.com Tel: +44 151 336 2266
Fortis C18™
- General HPLC use- Method dev. from pH 1-12- Acids, Bases and Neutral
Fortis Phenyl™
- Unique di-phenyl structure- Separate Positional Isomers- Metabolite profiling
Fortis H2o™
- Polar endcapped C18- Increased polar retention- Organic acids- Catecholamines
Fortis C8™
- Reduced Hydrophobicity- Lipids- Steroids
Fortis Cyano™
- Cyano functionality- RP or NP use- Explosives- Pesticides
Fortis HILIC™
- High Polar Retention- Highly Pure Silica- Carboxylic acids - Nucleotides
Fortis Method Development Options– Choice of Stationary phase functionality– Based on Ultra pure silica– Reversed Phase (RP) and Normal Phase (NP) options
9
Method D
ev
www.fortis-technologies.com Tel: +44 151 336 2266
Fortis Phenyl™
- Unique di-phenyl structure- Separate Positional Isomers- Metabolite profiling
Fortis C8™
- Reduced Hydrophobicity- Lipids- Steroids
10
Met
hod
Dev
Minutes0 1 2 3 4 5 6 7 8 9 10
mA
U
0
50
100
150
200
250
mA
U
0
50
100
150
200
250
0.04
20
.00
0
0.1
981.
05
197
0.9
601.
323
1901
1.85
81.
046
9867
2.78
80.
986
9056
4.9
800.
967
6211
6.53
31.
271
3662
7.4
98
0.9
774
047
M inutes0 1 2 3 4 5 6 7 8 9 10
mA
U
0
50
100
150
200
250m
AU
0
50
100
150
200
250
0.88
81.
262
3337
1.59
71.
125
7634
2.4
601.
066
3404
4.1
451
.02
8057
1
6.23
81.
018
3630
M inutes0 1 2 3 4 5 6 7 8 9 10
mA
U
0
50
100
150
200
250
mA
U
0
50
100
150
200
250
0.0
43
1.0
749
9
1.0
83
1.2
630
145
1.97
51
.12
6333
0
2.5
271.
145
8531
3.40
21.
037
6994
4.3
371
.01
8026
8
Minutes0 1 2 3 4 5 6 7 8 9 10
mAU
0
50
100
150
200
250
0
50
100
150
200
250
Minutes0 1 2 3 4 5 6 7 8 9 10
mA
U
0
50
100
150
200
250
mA
U
0
50
100
150
200
250
0.9
63
1.3
324
885
1.8
701
.19
6902
5
2.70
51.
147
3634
4.3
881.
08
888
78
6.1
171
.05
8907
9
Fortis C8™
Fortis C18™
Fortis Phenyl™Fortis H2o™
Fortis Cyano™
Getting Started :Method development typically starts with a C18 or C8 column, both provide Hydrophobic retention with good peak shapes for neutral, acidic and basic analytes. Generally if retention of polar molecules is also needed then a polar endcapped stationary phase such as Fortis H2o is a good starting choice.If selectivity is insufficient then Phenyl or Cyano stationary phases are a good alternative, they will change selectivity and even elution order since they work on dipole characteristics as opposed to just hydrophobicity.Fortis Cyano is good in normal phase (NP) conditions for polar analytes with COOH, NH2, NHR2 or NR2 groups. If small polar molecules still do not retain then HILIC chromatography is a suitable alternative.
Acidic, Neutral & basic analytes- Fortis C18- Fortis C8- Fortis Phenyl
Polar basic molecules- Fortis C18 operated at high pH- Fortis Phenyl- Fortis H2o
Polar acidic molecules- Fortis H2o- Fortis HILIC- Fortis Cyano in NP mode
Alternate Selectivity- Fortis Phenyl- Fortis Cyano
Extra PolarRetention
ExtraSelectivity
LowerHydrophobicity
ChangeSelectivity
www.fortis-technologies.com Tel: +44 151 336 2266
Fortis C18™
– Superior Peak Shapes– pH Range 1-12– Based on Ultra Pure Silica – Fully Scalable
Fortis C18 is a pure silica based stationary phase with unique high and low pH performance. Whether carrying out simple compound screens or complex metabolite identification Fortis C18 will provide the best in peak shape, resolution and extended pH range for method development flexibility.
Optimised Peak Shape
L1380m
2/g
17%
C18
2.5µ
3µ
5µ 1
0µ
Column: Fortis C18 100x4.6mm 3µ
p/n: F18-050503
Mobile Phase: A - H2O + 0.1% Formic acid B - ACN + 0.1% Formic acid
Gradient: 25 - 40% in 10min
Flow: 1ml/min
Temp: 20°C
Wavelength: 254nm
1. Protriptyline
2. Nortriptyline
3. Amitriptyline
4. Trimipramine
Whatever the compound functionality the optimised hydrophobic bonding of Fortis C18 leads to peak symmetries being near perfect whatever the analyte type.
Basic, Acidic and Neutral analyte performance is first class across the pH spectrum.
– Superior Peak Shapes- Higher Efficiencies– Greater Reproducibility
Minutes0 1 2 3 4 5 6 7 8 9 10
Extreme pH range
Fortis C18 has the ability to not only operate at low pH like other silica based phases, but also to operate at high pH to aid with basic analyte retention and performance.
The ability to quickly equilibrate from formic acid or TFA into ammonia or bicarbonate aids in method development. Mass transfer, loadability and precision of a silica matrix are all maintained.
– Higher Efficiency than Hybrids- Greater Reproducibility– Retain polar basic analytes
High pH ComparisonHigh pH Comparison
50
100
150
200
250
300
350
Minutes0 2 4 6 8 10 12 1450
100
150
200
250
300
350
Columns: 150x4.6mm 3μ Mobile Phase: 50:50 0.1% NH3 : MeCN Flow: 1.0ml/min Temp: 25°C Wavelength: 230nm
Fortis C18™
Hybrid C18
Asy - 0.97N - 112,225Rs - 2.28
Asy - 1.22N- 71,865Rs - 1.51
11
Fortis PhenylFortis C
18
www.fortis-technologies.com Tel: +44 151 336 2266
Columns: 150x4.6mm 3μ Mobile Phase: 50:50 0.1% NH3 : MeCN Flow: 1.0ml/min Temp: 25°C Wavelength: 230nm
pH 1
pH 6
pH 12
0 2 4 6 8 10 12 14
-0.02
0.00
0.02
0.04
0.06
7.61
0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2
Minutes
12
Forti
s Phe
nyl
Forti
s C18
Minutes0 2 4 6 8 10 12 14
Minutes0 1 2 3 4 5 6 7 8 9 10
Column: Fortis C18 100x4.6mm 3µ
p/n: F18-050503
Mobile Phase: A - H2O + 0.1% Formic acid B - ACN + 0.1% Formic acid
Gradient: 10 - 50% in 10min
Flow: 1ml/min
Temp: 20°C
Wavelength: 254nm
1. Dexamethasone
2. Neomycin Sulphate
3. Acetic acid
Column: Fortis C18 50x4.6mm 5µ
p/n: F18-050305
Mobile Phase: A - 50mM NH4OAc B - ACN
Gradient: 10 - 40% in 10min
Flow: 1ml/min
Temp: 20°C
Wavelength: 254nm
1. Quetiapine
Column: Fortis C18 50x3.0mm 3µ
p/n: F18-030303
Mobile Phase: 30:70 H2O + 10mM ammonium bicarbonate : MeOH
Flow: 0.4ml/min
Temp: 25°C
Wavelength: MS Detection
Raloxifene Glucuronides
Data Courtesy of : Pharmaceutical company, USA
Extended pH RangeInflammation and Infection
Antipsychotic
Selective Estrogen Modulator
www.fortis-technologies.com Tel: +44 151 336 2266
Optimised Resolution
Only by optimising all factors of stationary phase design can the analyst be assured of the best possible chromatography.
Fortis C18’s unique bonded character ensures that not only is reproducibility and robustness assured, but also that resolution is of the highest level. Only by obtaining sharp peak shapes for many analyte types can this sort of resolution be achieved.
Analysed here are 135 transitions of pesticide residues. Good LC resolution leads to excellent sensitivity in MS detection.
XIC of +MRM (135 pairs): 184.0/143.0 amu from Sample 17 (Coltest_017) of DataColtest.wiff (Turbo Spray) Max. 9.2e4 cps.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24Time, min
0.0
5.0e4
1.0e5
1.5e5
2.0e5
2.5e5
3.0e5
3.5e5
4.0e5
4.5e5
5.0e5
5.5e5
6.0e5
3.16
7.696.064.822.85
Minutes0 5 10 15 20 25
Data Courtesy of : Central Science Laboratories, UK
Column: Fortis C18 150x2.1mm 3μ
13
Fortis C18
High pH Stability
The unique bonding of Fortis C18 enables stability at extremes of pH to be maintained.
Run continuously in 0.1% ammonia Fortis C18 shows no deterioration in efficiency over a 90 day period.
Fortis C18™
135 Pesticide Transitions
www.fortis-technologies.com Tel: +44 151 336 2266
Fortis C18 Guards Length
10
Column Diameter 2.1 F18-0200xxG
4.6 F18-0500xxG
Fortis C18 Column Length
50 100 150 250
2.1 F18-0203xx F18-0205xx F18-0207xx -
Column Diameter 3.0 F18-0303xx F18-0305xx F18-0307xx -
4.6 F18-0503xx F18-0505xx F18-0507xx F18-0509xx
Replace xx - 02 for 2.5µm - 03 for 3µm - 05 for 5µm - 10 for 10µm
Hydrophobicity
Fortis C18 high surface area combined with the optimised C18 ligand bonding provides high retention for compounds.This is advantageous in a number of ways:
- Higher retention of analytes, more organic modifier can be used to elute, therefore greater MS sensitivity.
- Higher retention of analytes, more organic leads to shorter ‘dry-down’ in fraction collection.
- Higher retention of analytes, more chance of resolution
9.75 10.00 10.25 10.50 10.75 11.00 11.25 11.50 11.75 12.00
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.1
208.15 (1.00)194.15 (1.00)180.15 (2.51)150.15 (1.00)136.15 (1.83)
MD
EA
/11.2
00
MD
MA
Ecsta
sy/1
0.6
67
MD
A/1
0.0
00
Me
tha
mpheta
min
e/1
0.9
17
Am
pheta
min
e/1
0.2
17
10 10.5 11.0 11.5 12.0
Minutes
14
Forti
s C18
Column: Fortis C18 150x3.0mm 3µ
p/n: F18-030703
Mobile Phase: A - H2O + 0.1% ammonia B - MeOH + 0.1% ammonia
Gradient:
Flow: 0.4ml/min
Temp: 20°C
Wavelength: MS Detection
1. MDA (3,4-Methylenedioxyamphetamine)
2. Amphetamine
3. MDMA (Ecstasy)
4. Methaphetamine
5. MDEA (3,4-Methylenedioxy-N-ethylamphetamine)
Drugs of Abuse
Data Courtesy of : Forensic Laboratory, UK
Fortis C18™
www.fortis-technologies.com Tel: +44 151 336 2266
Fortis Phenyl™
– Unique Selectivity– Separate Positional Isomers– No “MS bleed”, stable hydrophobic ligand– Enhanced Polar Retention
Fortis Phenyl is designed to provide characteristics which will enhance selectivity. It provides the analyst with extra retention of compounds containing aromatic functionality. Extra selectivity and retention can be found for polar substrates, along with metabolite profiling.
Unique Functionality
Fortis Phenyl is based upon a unique di-phenyl functionality. Three controlled mechanisms of interaction can occur.
This allows for unique resolution of closely related species, and metabolites. No complex mobile phases are necessary simplifying method development.
– π-π High Selectivity– Resolution enhanced– Sharp Peak Shapes- Highly Stable phenyl ligand
L11380m
2/g
13%
Diphenyl
2.5µ
3µ
5µ 1
0µ
Separate Positional Isomers
Column: Fortis Phenyl 150x4.6mm 5µ
p/n: FPH-050705
Mobile Phase: 40:60 H2O : MeOH
Flow: 1ml/min
Temp: 20°C
Wavelength: 210nm
1. 4-Hydroxyestradiol (mw=288.38)
2. 2-Hydroxyestradiol (mw=288.38)
Selectivity of compounds normally difficult to resolve on a hydrophobic alkyl chain stationary phase is simplified by the π-π interactions provided by the phenyl functionality.
In this application two hydroxyestradiol steroids exhibit resolution from each other, which is not achievable on alkyl chain phases. No complex mobile phases are necessary.
– High Selectivity– Resolution enhanced– Sharp Peak Shapes
Minutes
50
75
100
125
150
175
200
50
75
100
125
150
175
200OH
OH
CH3
OH
H
H
H
OH
CH3
OH
H
H
H
OH
0 2 4 6 8 10 12 14
15
Fortis Phenyl
Hydrophobicity(alkyl chain)
Steric Selectivity(diphenyl arrangement)
π-π(phenyl rings)
www.fortis-technologies.com Tel: +44 151 336 2266
Fortis Phenyl Guards Length
10
Column Diameter 2.1 FPH-0200xxG
4.6 FPH-0500xxG
Fortis Phenyl Column Length
50 100 150 250
2.1 FPH-0203xx FPH-0205xx FPH-0207xx -
Column Diameter 3.0 FPH-0303xx FPH-0305xx FPH-0307xx -
4.6 FPH-0503xx FPH-0505xx FPH-0507xx FPH-0509xx
Replace xx - 02 for 2.5µm - 03 for 3µm - 05 for 5µm - 10 for 10µm
PET Tracer - PK11195
Column: Fortis Phenyl 150x4.6mm 5µ
p/n: FPH-050705
Mobile Phase: 40 : 60 H2O : ACN
Flow: 1ml/min
Temp: 25°C
Wavelength: MS Detection
1. Dechlorinated PK111952. PK11195
Antiarrhythmic
Column: Fortis Phenyl 150x4.6mm 5µ
p/n: FPH-050705
Mobile Phase: 70 : 30 H2O + 0.1% formic acid MeOH
Flow: 1ml/min
Temp: 25°C
Wavelength: 235nm
1. Quinidine
2. Dihydroquinidine• Column : • p/n : • Mobile Phase:
• Flow : • Temp : •
0.0 2.5 5.0 7.5 10.0 12.5 15.0
319.00 (1.00)353.00 (1.00)
Minutes
• Column : • p/n : • Mobile Phase:
• Flow : • Temp : •
Minutes0 2 4 6 8 10 12 14 16 18 20
60
80
100
120
140
160
180
Minutes
0 2.5 5.0 7.5 10 12.5 15
Data Courtesy of : Wolfson Molecular Imaging Centre
353.00 (1.00)319.00 (1.00)
0 2 4 6 8 10 12 14 16 18 20
16
Forti
s Phe
nyl
2.1µm Fortis Phenyl page 5
Di-phenyl vs C18
Selectivity of the Fortis di-phenyl is radically different to that of a C18 stationary phase.
In this pharmaceutical mixture we can see an increase in retention of the parent drug, whilst the degradents are all eluted quickly, removing them from co-elution with the parent.
Selectivity such as this can be extremely useful, combined with the ability to separate closely related species such as metabolites and positional isomers.
Minutes
50
75
100
125
150
14
60
80
100
120
140
160
180
200
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
Fortis™ Phenyl
Fortis™ C18
Data Courtesy of : Major Pharmaceutical company, USA
www.fortis-technologies.com Tel: +44 151 336 2266
0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
6.0
6.5
(x1,000)
73.00 (1.00)91.00 (1.00)117.00 (1.00)
0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75
0.25
0.50
0.75
1.00
1.25
1.50
1.75
2.00
(x10,000)
73.00 (1.00)91.00 (1.00)117.00 (1.00)
Fortis H2o’s unique bonded character ensures that not only is reproducibility and robustness assured, but also that resolution is of the highest level.
Fortis H2o is optimised not only to help retain and resolve polar analytes, but also to be complimentary in resolution to Fortis C18.
– Hydrophilic as well as Hydrophobic interaction’s– Alternative Selectivity– No MS bleed
Fortis H2o™
– Retention of Polars– Enhanced Resolution– 100% Aqueous Compatible– Fully Scalable
Fortis H2o is designed to aid in the separation and retention of polar analytes. Complex mobile phase systems can be bypassed if sufficient retention can be provided by the stationary phase chemistry. Fortis H2o is designed to supply additional interaction with polar molecules which allows their successful retention.
Alternative Selectivity - Organic acids
Retention of Polar analytes
Column : Fortis H2o 150x4.6mm 5µ
p/n : FHO-050705
Mobile Phase: H2O + 0.1% Formic acid
Flow : 0.8ml/min
Temp : 20°C
Wavelength: 270nm
1. Dopamine
2. Serotonin
3. DOPAC
4. 5-HIAA
Column: Fortis H2o 150x2.1mm 3µ
p/n: FHO-020703
Mobile Phase: 5mM Ammonium Formate + 0.5% Formic acid
Flow: 0.4ml/min
Temp: 60°C
Wavelength: MS Detection
Minutes
L1380m
2/g
18%
3µ 5
µ 10
µ
Polar Endcapping
0 1 2 3 4 5 6 7 8 9 10
17
Fortis H2o
Methylmalonic acid
Succinic acid
Neurotransmitters
www.fortis-technologies.com Tel: +44 151 336 2266
Fortis C8™
– Reduced Hydrophobicity over C18– Excellent Peak Shapes– Fully Scalable
Fortis C8 is designed to provide characteristics similar to Fortis C18 but specifically for situations where less hydrophobicity is required. The same gains in peak shape, efficiency, resolution and scalability are available providing increased productivity to the analyst.
Optimised Peak Shape
L7380m
2/g
13%
C8
2.1µ
3µ
5µ 1
0µ
Column: Fortis C8 150x4.6mm 5µ
p/n: F08-050705
Mobile Phase: A - H2O + 0.1% Formic acid B - MeOH + 0.1% Formic acid
Gradient: 10 - 90% in 10min
Flow: 1ml/min
Temp: 25°C
Wavelength: 254nm
1. Lamotrigine
Fortis C8 is optimised to provide the best possible peak shapes and efficiency.
Basic, Acidic and Neutral analyte performance is first class.
– Higher Efficiencies– Greater Reproducibility– Symmetrical peak shapes- Lower Hydrophobicity
Minutes0 1 2 3 4 5 6 7 8 9 10
Minutes0 1 2 3 4 5 6 7 8 9 10
200
400
600
800
1000
Minutes0 1 2 3 4 5 6 7 8 9 10
100
150
200
250
300
Minutes0 1 2 3 4 5 6 7 8 9 10
Anticonvulsant
Minutes0 1 2 3 4 5 6 7 8 9 10 11 12
60
80
100
120
140
160
1.39
80.
7829
51
2.66
21.
2158
942
6.08
81.
1686
411
Minutes 0 1 2 3 4 5 6 7 8 9 10 11 12
Antiplatelet
Column: Fortis C8 150x4.6mm 5µ
p/n: F08-050705
Mobile Phase: 40 : 60 H2O + 0.1% formic acid ACN
Flow: 1ml/minTemp: 25°C
Wavelength: 220nm
1. Valproate Semisodium
Column: Fortis C8 150x4.6mm 5µ
p/n: F08-050705
Mobile Phase: 25 : 75 H2O : ACN
Flow: 1ml/minTemp: 25°C
Wavelength: 254nm
1. Clopidogrel
18
Forti
s C8
Bipolar disorders
www.fortis-technologies.com Tel: +44 151 336 2266
Fortis Cyano™
– Retention of Polars– Alternative Selectivity– Normal Phase or Reverse Phase system– Rapid Equilibration
Fortis Cyano allows the use of aqueous reversed phase conditions to provide less retention for compounds too heavily retained on C18 functionality. However, it can also be used in normal phase solvent systems to retain and separate polar analyte species.Cyano columns are particularly useful for polar species, Fortis Cyano is now also available in 2.1µm particle size for UHPLC work.
L10380m
2/g
7%
2.1µ
3µ
5µ
Cyano
Fortis Cyano Guards Length
10
Column Diameter 2.1 FCN-0200xxG
4.6 FCN-0500xxG
Fortis Cyano Column Length
50 100 150 250
2.1 FCN-0203xx FCN-0205xx FCN-0207xx -
Column Diameter 3.0 FCN-0303xx FCN-0305xx FCN-0307xx -
4.6 FCN-0503xx FCN-0505xx FCN-0507xx F18-0509xx
Replace xx - 02 for 2.1µm - 03 for 3µm - 05 for 5µm
19
Fortis Cyano
Fortis Cyano is optimised not only to help retain and resolve polar analytes, but also to be complimentary in resolution to other Fortis phases.
– Normal phase as well as Reversed phase use– Alternative Selectivity– Rapid Equilibration
Herbicides
Column : Fortis Cyano 50x2.1mm 3µ
p/n : FCN-020303
Mobile Phase: 80:20 H2O : ACN + 0.2% Acetic acid
Flow : 0.2ml/min
Temp : 20°C
Wavelength: 280nm
1. Banvel
2. Int Std
3. 2,4-D
4. MCPA
5. PCOC
6. 2,4-DCP
7. 2,4-DP
8. CMPP
9. 2,4-DB
10. MCPB
Minutes
0
50
100
150
200
250
300
350
0
50
100
150
200
250
300
350
0.6
77
1.2
03
74
44
1.4
70
0.7
43
30
24
1.7
70
1.3
41
61
06
4
2.0
00
1.5
80
3.0
13
1.0
22
18
29
8
3.2
17
1.2
43
36
50
4
4.6
28
0.8
51
93
67
1
5.2
42
0.9
12
28
95
2
5.8
58
0.9
12
60
62
0
6.2
10
1.0
92
72
05
4
6.7
53
0.9
32
33
99
9
7.5
35
0.9
42
50
18
3
12
.9
80
0.0
02
12
99
5
13
.5
63
0.0
02
33
48
9
0 2 4 6 8 10 12 14
To see more applications on Fortis Cyano turn to page 26. To learn more about Fortis Cyano 2.1µm see page 7.
Herbicides
www.fortis-technologies.com Tel: +44 151 336 2266
Fortis HILIC™
– Retention of Polars– Increased MS sensitivity– Alternate selectivity– Reduced extraction (SPE) and dry down times.
Fortis HILIC (Hydrophilic Interaction Chromatography) is designed to aid in the separation and retention of very polar analytes. Extended retention is afforded by the partitioning, ion-exchange and hydrogen bonding that can occur on a HILIC stationary phase. Fortis HILIC can increase sensitivity in MS analysis and provide alternate selectivity to that achieved with reversed phase C18.
L3380m
2/g
na
3µ, 5
µ
HILIC
Fortis HILIC Guards Length
10
Column Diameter 2.1 FHI-0200xxG
4.6 FHI-0500xxG
Fortis HILIC Column Length
50 100 150 250
2.1 FHI-0203xx FHI-0205xx FHI-0207xx -
Column Diameter 3.0 FHI-0303xx FHI-0305xx FHI-0307xx -
4.6 FHI-0503xx FHI-0505xx FHI-0507xx FHI-0509xx
Replace xx - 03 for 3µm - 05 for 5µm - 10 for 10µm
20
Forti
s HIL
IC
Fortis HILIC is optimised to help retain and resolve polar analytes. By use of high concentrations of organic solvent polar analytes partition with the stationary phase.
– Polar Retention– Alternative Selectivity– Rapid Equilibration
Nucleosides
Column : Fortis HILIC 50x4.6mm 5µ
p/n : FHI-050305
Mobile Phase: 95:5 ACN : 100mM NH3OAc
Flow : 1ml/min
Temp : 20°C
Wavelength: 254nm
1. Uracil
2. Uridine
3. Cytosine
4. Guanosine
Minutes
10
20
30
40
10
20
30
400
.6
10
.85
14
00
1.2
10
.8
52
21
7
4.8
91
.1
42
62
7
6.8
41
.18
29
85
0 1 2 3 4 5 6 7 8 9 10
Hydrophilic Interaction Chromatography (HILIC) works in a similar way to normal phase chromatography. A polar surface combined with a non-polar mobile phase, typically ACN, allows for partition of the polar analytes and hence retention and separation. Water is used in low concentration as the strong solvent in order to elute the compounds.
60 70 80 90% organic
Adenine
Theobromine
Uracil
Toluene8
6
4
2
10
k’
Nucleoside’s
www.fortis-technologies.com Tel: +44 151 336 2266
Fortis – LC-MS Optimised Hardware– 20mm and 30mm lengths- High Throughput– High Efficiency and Resolution
Fortis Pace™ columns are designed with High Throughput Screening (HTS) applications in mind. Optimised for use in LC-MS to provide greatest sensitivity by achieving sharp peak shapes combined with excellent resolution and retention. Any Fortis stationary phase can be supplied in this hardware.
Optimised Hardware
Fortis stationary phases have been proven to exhibit excellent peak shapes and efficiency, packed in Pace hardware allows speed and resolution to be achieved without the need for UHPLC systems.
Providing highly retentive and selective phases allows strong retention properties, enabling high concentrations of organic modifier to be utilised optimising the MS ionisation process.
Gains are also made in:
- Reduced analysis time- Increased productivity- Lower solvent consumption
Column: Fortis Pace C18 30x2.1mm 5µ
p/n: F18-020205
Mobile Phase: A - H2O + 0.1% Formic acid B - ACN + 0.1% Formic acid
Gradient: 60 - 90% in 2min
Flow: 1ml/min
Temp: 25°C
Wavelength: 254nm
1. Alkyl Benzenes
Column: Fortis Pace C18 30x2.1mm 5µ
p/n: F18-020205
Mobile Phase: 75:25 H2O:ACN + 0.1% Formic acid
Flow: 0.4ml/min
Temp: 25°C
Wavelength: 254nm
1. Rosuvastatin
2. Atorvastatin
Fortis Pace column hardware is specifically designed for HTS, whether isocratic or by ballistic gradients. Optimised packing density in this low volume hardware leads to ultra sharp peak shapes combined with maximum efficiency.
– Reduced peak widths– Higher Efficiency– Resolution enhanced
Minutes 0.0 0.5 1.0 1.5 2.0 2.5 3.0
Minutes0.0 0.2 0.4 0.6 0.8
Complimentary Stationary Phases
Strength in Technology
Alkyl Benzenes• Column : Fortis C18 30x2.1mm 5• p/n : F18-020205• Mobile Phase:
A – H2O + 0.1% Formic acidB – ACN + 0.1% Formic acid
• Gradient: 60 – 90% in 2min
• Flow : 1 ml/min• Temp : 25oC• : 254nm
1. Alkyl Benzenes
Minutes0.0 0.5 1.0 1.5 2.0 2.5 3.0
Vol
ts
Vol
ts
0.000
0.002
0.004
0.006
0.008ACS
Strength in Technology
Alkyl Benzenes• Column : Fortis C18 30x2.1mm 5• p/n : F18-020205• Mobile Phase:
A – H2O + 0.1% Formic acidB – ACN + 0.1% Formic acid
• Gradient: 60 – 90% in 2min
• Flow : 1 ml/min• Temp : 25oC• : 254nm
1. Alkyl Benzenes
Minutes0.0 0.5 1.0 1.5 2.0 2.5 3.0
Vol
ts
Vol
ts
0.000
0.002
0.004
0.006
0.008ACS
Strength in Technology
Statins• Column : Fortis C18 30x2.1mm 5• p/n : F18-020205• Mobile Phase:
75:25 ACN:H20+ 0.1% Formic acid
• Flow : 0.4 ml/min• Temp : 25oC• : 254nm
1. Rosuvastatin2. Atorvastatin
Minutes0.0 0.2 0.4 0.6 0.8
0.18
71.3
7671
9
Retention TimeAsymmetry (10%)Theoretical plates / meter
21
Fortis PaceStatins
www.fortis-technologies.com Tel: +44 151 336 2266
Applications
SSRI Antidepressant
Column: Fortis Pace H2o 30x2.1mm 3µ
p/n: FHO-020203
Mobile Phase: 70:30 H2O : ACN + 0.1% Formic acid
Flow: 0.6ml/min
Temp: 25°C
Wavelength: 200nm
1. Paroxetine
Benzodiazepines
Column: Fortis Pace H2o 30x2.1mm 3µ
p/n: FHO-020203
Mobile Phase: 50:50 ACN : H2O
Flow: 0.7ml/min
Temp: 25°C
Wavelength: 220nm
1. Lorazepam
2. Temazepam
3. Diazepam
Antidepressant
1. Mirtazapine
Sulfa Drugs
Column: Fortis Pace H2o 30x2.1mm 3µ
p/n: FHO-020203
Mobile Phase: 70:30 H2O : ACN + 0.1% Formic acid
Flow: 0.2ml/min
Temp: 25°C
Wavelength: 254nm
1. Sulfathiazole
2. Sulfamerazine
3. Sulfamethoxazole
Column: Fortis Pace C18 30x2.1mm 5µ
p/n: F18-020205
Mobile Phase: 80:20 H2O : MeOH + 0.1% Formic acid
Flow: 0.7ml/min
Temp: 25°C
Wavelength: 254nm
Strength in Technology
Paroxetine• Column : Fortis H2o 30x2.1mm 3• p/n : FHO-020203• Mobile Phase:
70:30 H2O:ACN+ 0.1% Formic acid
• Flow : 0.6 ml/min• Temp : 25oC• : 200nm
1. Paroxetine
Minutes0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
0
2
4
6
0.06
70.0
00
0.66
21.4
5 473
03
Retention TimeAsymmetry (10%)Theoretical plates / meter
Minutes
Strength in Technology
Mirtazepine• Column : Fortis C18 30x2.1mm 5• p/n : F18-020205• Mobile Phase:
80:20 H20 : MeOH+0.1% Formic acid
• Flow : 0.7 ml/min• Temp : 25oC• : 254nm
1. Mirtazepine
Minutes0.0 0.5 1.0 1.5 2.0 2.5 3.0
Vol
ts
0.000
Vol
ts
0.000
0.001
0.002
0.003
1.55
0 ACS
Minutes
Strength in Technology
Sulfa Drugs• Column : Fortis H2o 30x2.1mm 3• p/n : FHO-020203• Mobile Phase:
70:30 H20 : ACN+0.1% Formic acid
• Flow : 0.2 ml/min• Temp : 25oC• : 254nm
1. Sulfathiazole2. Sulfamerazine3. Sulfamethoxazole
Minutes0.0 0.5 1.0 1.5 2.0 2.5 3.0
Vol
ts
0.00
0.01
0.02
0.03
0.04
0.44
81.4
9 244
44
0.56
01.5
9345
01
1.06
01.3
8669
79
Retention TimeAsymmetry (10%)Theoretical plates / meter
Minutes
Strength in Technology
Benzodiazepines• Column : Fortis H2o 30x2.1mm 3• p/n : FHO-020203• Mobile Phase:
50:50 ACN:H20
• Flow : 0.7 ml/min• Temp : 25oC• : 220nm
1. Lorazepam2. Temazepam3. Diazepam
Minutes0.2 0.6 1.0 1.4 1.8
Vol
ts
0.00
0.01
0.02
0.03
0.04
2049
5052
2.6
10.2
ACS30x2-1 3um 07ml min Run3
Area
Minutes 0.2 0.6 1.0 1.4 1.8 0.2 0.6 1.0 1.4 1.8
0.0 0.5 1.0 1.5 2.0 2.5 3.0 0.0 0.5 1.0 1.5 2.0 2.5 3.0
Fortis Pace 3µ Column Length
20 30
2.1 Fxx-020103 Fxx-020203
Column Diameter 3.0 - Fxx-030203
4.6 Fxx-050203
Fortis Pace 5µ Column Length
20 30
2.1 Fxx-020105 Fxx-020205
Column Diameter 3.0 - Fxx-030205
4.6 - Fxx-050205
Replace xx with: 18 for Fortis C18; OH for Fortis H2o; PH for Fortis Phenyl; 08 for Fortis C8; CN for Fortis Cyano;
22
Forti
s Pac
e
www.fortis-technologies.com Tel: +44 151 336 226623
Fortis Prep
Fortis Prep™
– 5µm and 10µm particles– High Loadability– Optimised Packing Efficiency– Narrow peak profile, High Efficiency and Resolution
Fortis Prep columns are designed for high sample loading, high throughput applications. The optimised packed bed (OPB) process ensures excellent peak shapes and efficiency, whilst the lifetime of the column is increased.
Columns & BulkFortis Prep columns come in sizes from 30mm to 250mm in length and from 10mm in diameter all the way up to 50mm (2” i.d.).Pre-packed columns are advised for < 2” i.d. after this Bulk material can be supplied for those wishing to pack DAC (Dynamic Axial Compression) columns.
If preparative columns are packed with the identical media to their analytical counterpart then the ability to scale up with the theoretical calculations will be accurate.
- 10mm, 21.2mm, 30mm and 50mm i.d.- 5µm and 10µm particles- 100g to multi Kg bulk available
Contact us for more information on availability of prep options/bulk packings, or to discuss your application and the ability to scale up. Our technical experts will be happy to discuss your needs with you.
www.fortis-technologies.com Tel: +44 151 336 2266 24
Forti
s Gua
rds
Filter & Guard Options– Guard system for all 3µm, 5µm and 10µm phases– Low volume in-line filters for LC and UHPLC– Maintain chromatographic integrity
Fortis Guards and filters are designed to ensure that erroneous materials do not find there way onto the more important and expensive analytical column. Guards are available in sizes to match all analytical and preparative column dimensions. Filters are particularly suitable for short fast LC/MS (Pace™) columns and UHPLC columns.
– Guard system for all 3µm, 5µm and 10µm phases– Quick replacement cartridges- Highly Cost Effective
– Preparative guard system 10mm & 21.2mm– Quick replacement cartridges- Highly Cost Effective
– Filter for all LC columns– Low volume in-line filters– Change over time - seconds not minutes
Fortis in-line filters are fingertight direct connect design, fitting in between the column and the conventional peek fitting to filter out particulate matter, it contains low dead volume and pressure. In-line filters are ideal for very short fast columns such as Fortis Pace™ LC/MS columns where extra packed bed from a guard would be detrimental. In-line filters are also available in UHPLC format, capable of withstanding the elevated pressures involved.
3µm Fortis C18 Cartridges
F18-040003G/2 10x4mm Fortis C18 3µm Guard pk 2
F18-040003G/4 10x4mm Fortis C18 3µm Guard pk 4
F18-020003G/2 10x2mm Fortis C18 3µm Guard pk 2
F18-020003G/4 10x2mm Fortis C18 3µm Guard pk 4
5µm Fortis C18 Cartridges
F18-040005G/2 10x4mm Fortis C18 5µm Guard pk 2
F18-040005G/4 10x4mm Fortis C18 5µm Guard pk 4
F18-020005G/2 10x2mm Fortis C18 5µm Guard pk 2
F18-020005G/4 10x2mm Fortis C18 5µm Guard pk 4
In-line Filters
2-SAV5 2µm In-line filter pk 5
2-SAV10 2µm In-line filter pk 10
UHPSAV2 UHPLC In-line filter pk 2
UHPSAV4 UHPLC In-line filter pk 4
www.fortis-technologies.com Tel: +44 151 336 226625
Fortis QC
QC Reproducibility– Robust column bondings– Assured Peak shapes– 20% lower asymmetry specification– 10% Higher Efficiency
Fortis HPLC columns are tested using the industries most rigorous QC test, utilising basic analyte probes as well as neutral efficiency markers ensures that the column reproducibility is first class. Fortis columns are also subject to a 20% lower peak shape specification than other manufacturers columns.
Fortis stationary phases have been proven to exhibit excellent peak shapes and efficiency for the full range of analyte species.
By employing a QC mix that accurately probes silanol activity (the measure of good peak shape) the analyst can be assured of quality time and time again.
Gains are also made in:
- Sample carry over- Increased Resolution- Increased Sensitivity
Column: Fortis C18 100x4.6mm 5µ
p/n: F18-050505
Mobile Phase: 60:40 ACN:H2O
Flow: 1.0ml/min
Temp: 25°C
Wavelength: 254nm
1. Uracil
2. Phenol
3. 4-Ethylaniline
4. N,N-Dimethylaniline
5. Napthalene
Minutes0 1 2 3 4 5 6 7 8 9 10
QC Test
0 1 2 3 4 5 6 7 8 9 100.0
0.1
0.2
0.3
0.4
0.5
0.0
0.1
0.2
0.3
0.4
0.5
0.84
813
618
1.10
1.67
878
110
1.20
2.54
591
605
1.11
4.63
010
7875
1.04
7.00
210
4571
1.03
QC HP1050
Fortis columns are subject to tight specification using basic analytes in an unbuffered mobile phase system.If there were residual uncovered hydroxyl groups present then these basic probes would highlight this fact.
Fortis Technologies unique bondings combined with the ultra pure silica matrix ensure that the peak shapes achieved are first class.
Column Asymmetry Reproducibility
Asymmetry
500+ columns
www.fortis-technologies.com Tel: +44 151 336 2266
Casein Tryptic Digest
Minutes0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30
Column: 2.1µm Fortis C18(2) 100x2.1mm
p/n: F28-020502
Mobile Phase: A - H2O + 0.1% Formic acid B - ACN + 0.1% Formic acid
Gradient: 0min 5% B
5min 5% B
30min 20% B
35min 50% B
Flow: 0.25 ml/min
Temp: 35°C
Wavelength: 200nm
1. Casein
Antipsychotic
Column: Fortis Phenyl 150x4.6mm 5µ
p/n: FPH-050705
Mobile Phase: 35:65 H2O + 0.1% Formic acid : MeOH
Flow: 1ml/min
Temp: 25°C
Wavelength: 254nm
1. Prochlorperazine Maleate
Antimalarial
Column: Fortis Phenyl 50x4.6mm 5µ
p/n: FPH-050305
Mobile Phase: A: H2O + 0.1% formic acid B: MeOH + 0.1% formic acidGradient: 10 - 90% in 10mins
Flow: 1ml/min
Temp: 25°C
Wavelength: 254nm
1. Proguanil
Stemetil• Column : • p/n : • Mobile Phase:
• Flow : • Temp : •
Minutes0 1 2 3 4 5 6 7 8 9 10
50
60
70
80
90
Minutes
Paludrine• Column : • p/n : • Mobile Phase:
• Gradient:
• Flow : • Temp : •
Minutes1 2 3 4 5 6 7 8 9 10
100
200
300
400
500
600
700
800
Minutes0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10
Applications
26
App
licat
ions
www.fortis-technologies.com Tel: +44 151 336 2266
Applications
Opioid analgesic
Column: Fortis C18 50x2.1mm 5µ
p/n: F18-020305
Mobile Phase: A: H2O + 0.1% NH3
B: ACN + 0.1% NH3
Gradient: 10 - 100% in 5minsFlow: 0.2ml/min
Temp: Ambient
Wavelength: 220nm
1. Tramadol
Antibiotic
Column: Fortis C18 50x4.6mm 5µ
p/n: F18-050305
Mobile Phase: A: H2O + 0.1% formic acid B: ACN + 0.1% formic acidGradient: 10 - 100% in 10mins
Flow: 1ml/min
Temp: 25°C
Wavelength: 254nm
1. Phenoxymethylpenicilin
Vitamin
1. Vitamin C
Antibiotic
Column: Fortis Phenyl 150x4.6mm 5µ
p/n: FPH-050705
Mobile Phase: A: H2O + 0.1% formic acid B: MeOH + 0.1% formic acidGradient: 10 - 90% in 10mins
Flow: 1ml/min
Temp: 25°C
Wavelength: 254nm
1. Ciprofloxacin
Column: Fortis Phenyl 150x4.6mm 5µ
p/n: FPH-050705
Mobile Phase: 100% H2O + 0.1% Formic acid
Flow: 0.8ml/min
Temp: 25°C
Wavelength: 254nm
0.33
0
ACS1050 10-2-06 Run 2
Retention Time
Tramadol
Minutes
Vitamin C• Column : • p/n : • Mobile Phase:
• Flow : • Temp : •
Minutes0 1 2 3 4 5 6 7 8 9 10
0
2
4
6
8
10
12
14
Minutes
Ciprofloxacin• Column : • p/n : • Mobile Phase:
• Gradient:
• Flow : • Temp : •
Minutes0 1 2 3 4 5 6 7 8 9 10
200
400
600
800
1000
1200
6.84
3411
881.
30
8.41
00.
00
8.74
00.
00
9.06
00.
00
9.77
00.
00
Minutes
0 1 2 3 4 5 6 7 8 9 10Minutes
0 1 2 3 4 5 6 7 8 9 10 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10
27
Applications
www.fortis-technologies.com Tel: +44 151 336 2266
Applications
Adrenergic alpha-antagonist
Column: Fortis Phenyl 150x4.6mm 5µ
p/n: FPH-050705
Mobile Phase: 30:60 H2O + 0.1% Formic acid : MeOH
Flow: 1ml/min
Temp: 25°C
Wavelength: 254nm
1. Doxazosin
Explosives
Column: Fortis Cyano 50x2.1mm 3µ
p/n: FCN-020303
Mobile Phase: A: 80:20 H2O : MeOH B: ACN 90 : 10 Isocratic
Flow: 0.2ml/min
Temp: Ambient
Wavelength: 254nm
1. 4-Nitroaniline
2. 2-Nitroaniline
3. Nitrobenzene
4. 2,6-Dinitrotoluene
Stereoisomers
1. Isoascorbic acid
2. Ascorbic acid
Decongestant
Column: Fortis C18 100x4.6mm 3µ
p/n: F18-050503
Mobile Phase: 90 : 10 H2O : MeOH + 0.1% NH3
Flow: 1.2ml/min
Temp: 25°C
Wavelength: 210nm
1. Phenylephrine
Column: Fortis HILIC 50x4.6mm 5µ
p/n: FHI-050305
Mobile Phase: 90 : 10 ACN : NH3OAc
Flow: 1ml/min
Temp: 25°C
Wavelength: 254nm
• Column : • p/n : • Mobile Phase:
• Flow : • Temp : •
Minutes0.0 1.0 2.0 3.0 4.0 5.0 6.0
60
80
100
120
140
Minutes
0
2
4
6
8
0
2
4
6
8
0.2
31
.79
22
9
3.3
51
.08
28
80
Minutes
50
Minutes
0
10
20
30
40
0
10
20
30
40
1.0
80
1.4
16
86
78
2.6
05
1.1
61
97
75
8
2.8
97
1.1
92
22
03
9
3.2
08
1.2
72
29
54
4
4.9
38
1.1
52
61
38
0
Minutes0 1 2 3 4 5 6 7 8 9 10
0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9
28
App
licat
ions
0 1.0 2.0 3.0 4.0 5.0 6.0
www.fortis-technologies.com Tel: +44 151 336 2266
Applications
Proton Pump Inhibitor
Column: Fortis C18 100x4.6mm 3µ
p/n: F18-050503
Mobile Phase: A: H2O + 0.1% Formic acid B: ACN + 0.1% Formic acidGradient: 10 - 100% in 10minsFlow: 1.0ml/min
Temp: 25°C
Wavelength: 254nm
1. Omeprazole
Antiretroviral - HIV
Column: Fortis C18 150x4.6mm 5µ
p/n: F18-050705
Mobile Phase: A: H2O + Buffer B: MeOH + ACN
Flow: 1.0ml/min
Temp: 25°C
Wavelength: 215nm
Amprenavir
Non Steroid Anti-Inflammatory
1. Diclofenac Sodium
Anticonvulsant
Column: Fortis C8 150x4.6mm 5µ
p/n: F08-050705
Mobile Phase: A: H2O + 0.1% formic acid B: MeOH + 0.1% formic acidGradient: 10 - 90% in 10mins
Flow: 1.0ml/min
Temp: 25°C
Wavelength: 254nm
1. Lamotrigine
Column: Fortis C18 100x4.6mm 5µ
p/n: F18-050505
Mobile Phase: A: H2O + 0.1% Formic acid B: ACN + 0.1% Formic acidGradient: 50 - 100% in 10minsFlow: 1.0ml/min
Temp: Ambient
Wavelength: 254nm
0.04
0.06
0.08
0.10
0.12
0.14
0.04
Minutes
Minutes0 1 2 3 4 5 6 7 8 9 10
200
400
600
800
1000
Minutes
Minutes0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10
0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10
29
Applications
Saquinavir
Nelfinavir
Atazanavir
Ritonavir
Lopinvir
IS
www.fortis-technologies.com Tel: +44 151 336 2266
Applications
Antihistamine
Column: Fortis C18 100x4.6mm 5µ
p/n: F18-050505
Mobile Phase: A: H2O + 0.1% Formic acid B: ACN + 0.1% Formic acidGradient: 10 - 100% in 10minsFlow: 1.0ml/min
Temp: 22°C
Wavelength: 254nm
1. Loratadine
Antipsychotic
Column: Fortis C18 50x4.6mm 5µ
p/n: F18-050305
Mobile Phase: A: H2O + 0.1% formic acid B: ACN + 0.1% formic acidGradient: 10 - 100% in 5mins
Flow: 1.0ml/min
Temp: 25°C
Wavelength: 254nm
1. Haloperidol
Hypertension
1. Diltiazem
Antidepressant
Column: Fortis C18 50x4.6mm 3µ
p/n: F18-050303
Mobile Phase: A: H2O + 0.1% formic acid
B: ACN + 0.1% formic acidGradient: 10 - 100% in 10mins
Flow: 1.0ml/min
Temp: 20°C
Wavelength: 254nm
1. Fluoxetine
Column: Fortis H2o 50x4.6mm 5µ
p/n: FHO-050305
Mobile Phase: A: H2O + 0.1% formic acid B: ACN + 0.1% formic acidGradient: 10 - 100% in 10mins
Flow: 1.0ml/min
Temp: 25°C
Wavelength: 254nm
0.05
0.10
0.15
0.20
0.25
0.05
0.10
0.15
0.20
0.25
Minutes
0.01
0.02
0.03
0.04
0.05
0.01
0.02
0.03
Minutes Minutes
0 1 2 3 4 5 6 7 8 9 10
0.05
0.06
0.07
0.08
0.09
0.05
Minutes0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 10
30
App
licat
ions
45 Coalbrookdale RoadClayhill Industrial ParkNeston Cheshire, UKCH64 3UG
t: +44 151 336 2266f: +44 151 336 2669 www.fortis-technologies.com e: [email protected]
Applications Index
For technical support or applications contact :
For more information VISIT :
www.fortis-technologies.com
11αHydroxyprogesterone 817αHydroxyprogesterone 82,4-D 202,4-DB 202,4-DCP 202,4-DP 202,6-Dinitrotoluene 292-Hydroxyestradiol 162-Nitroaniline 294-Ethylaniline 264-Hydroxyestradiol 164-Nitroaniline 295-HIAA 18Acetic acid 13Adenine 21Alkyl Benzenes 22Amitriptyline 9, 12, 32Amphetamine 15Amprenavir 30Ascorbic acid 29Atazanavir 30Atorvastatin 22Banvel 20Casein Tryptic Digest 27Cefachlor 5Cefadroxil 5Cefalexin 5Cefradine 5Ciprofloxacin 28Clopidogrel 19CMPP 20Cortisone 8Cytosine 21Dexamethasone 13Diazepam 23
Diclofenac Sodium 30Dihydroquinidine 17Diltiazem 31DOPAC 18Dopamine 18Doxazosin 29Ecstasy 15Fluoxetine 31Gliclazide 6Guanosine 21Haloperidol 31Hydroxy-21-acetate 8Isoascorbic acid 29Lamotrigine 19, 30Lopinavir 30Loratadine 31Lorazepam 23MCPA 20MCPB 20MDA (3,4-Methylenedioxyamphetamine) 15MDEA (3,4-Methylenedioxy-N-ethylamphetamine) 15MDMA (Ecstasy) 15Methaphetamine 15Methylmalonic acid 18Mirtazapine 23N,N-Dimethylaniline 26Napthalene 26Nelfinavir 30Neomycin Sulphate 13Nitrobenzene 29Nortriptyline 9, 12Omeprazole 30Organic acids 18Paroxetine 23PCOC 20
Pesticide 14PET Tracer 17Phenol 26Phenoxymethylpenicillin 28Phenylephrine 29PK11195 17Prednisolone 8Prednisone 8Prochlorperazine Maleate 27Progesterone 8Proguanil 27Protriptyline 9, 12Quetiapine 13Quinidine 17Raloxifene Glucuronides 13Ritonavir 30Rosuvastatin 22Saquinavir 30Serotonin 18Succinic acid 18Sulfamerazine 23Sulfamethoxazole 23Sulfathiazole 23Telmisartan 7Temazepam 23Theobromine 21Toluene 21Tramadol 28Trimipramine 9, 12Uracil 21, 26Uridine 21Valproate Semisodium 19Vitamin C 28
Fortis C18™, Fortis Phenyl™, Fortis H2o™, Fortis C8™, Fortis Cyano™, Fortis HILIC™, Fortis Pace™ are trademarks of Fortis™ Technologies Ltd.Sunfire® and Xterra® are registered trademarks of Waters Corporation. Luna®, Gemini® and Synergi® are registered trademarks of Phenomenex. Zorbax® Eclipse XDB® is a registered trademark of Agilent Technologies. ACE® is a registered trademark of ACT. Fortis is not associated with these companies. Comparative separations may not be representative of all applications. All columns are original manufacturers own. ©2008-2009 Fortis Technologies Ltd. All rights reserved.