PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT...

120
PRODUCT CATALOGUE A UTC Fire & Security Company ZOOM PRINT EXIT PAGE 1/120 www.kfp.co.uk CONTENTS

Transcript of PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT...

Page 1: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

P R O D U C T C A T A L O G U E

A UTC Fire & Security Company

ZOOM PRINT EXITPAGE 1/120 www.kfp.co.uk CONTENTS

Page 2: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 2 3

Kidde Fire Protection is a leading brand within Kidde Products. Kidde Products are part of UTC Fire & Security, which provides fire safety and security solutions to more than one million customers around the world. Headquartered in Connecticut, U.S., UTC Fire & Security is a business unit of United Technologies Corp., which provides high technology products and services to the building and aerospace industries worldwide.

Kidde Fire Protection manufactures fire detection, and fire suppression systems in the UK providing product sales and customer support from our office in Thame, Oxfordshire. We do business in over one hundred countries throughout Europe, Africa, the Arbabian Gulf, Asia, South America and the Caribbean through an extensive network of over two hundred distributors. We also have local representation through Kidde sales offices around the world.

Our Investor in People accreditation demonstrates that its high standards of quality are reflected not only in the excellence of its products, but also in the skills and motivation of people throughout the organisation. Many of our technical staff are acknowledged experts in their fields and are members of national and international standards committees such as NFPA, CEN and ISO.

UTC Fire & Security maintains its position at the forefront of fire protection technology through continuous investment in research and development. Quality Management Systems which fully comply with the requirements of BS EN ISO 9001:2000 ensure that finished products will perform consistently and reliably. Sound practices at all Kidde Fire Protection manufacturing plants are designed to minimise environmental impact, by energy, raw materials and waste management.

Kidde Fire Protection is a proud and active member of the Fire Industry Association (FIA).

KIDDE FIRE PROTECTION

ZOOM PRINT EXITPAGE 2/120 www.kfp.co.uk HOME CONTENTS

Page 3: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 2 3

CONTROL PANELS

Intelligent Addressable Fire Alarm Panels 10Vega Networking Systems 16Autroprime 22Custom Design Control Panels 25Conventional Fire Alarm Panels 26Extinguishing Control Systems 29FireBeta Status Indicators 31

DETECTION AND ALARM

Detector types 38Discovery Intelligent Fire Detection 40XP95 Intelligent Fire Detection 44Intelligent Audio/Visual Signalling 49Standard Interfaces with Isolators 52Mini Interfaces 54Din-Rail Interfaces 55Orbis Conventional Fire Detection 58Mounting Accessories 62Test Equipment 64Conventional Audio/Visual Signalling 67Conventional Manual Call Points 71Door Release Equipment 72Sealed Lead Acid Batteries 73XP95 Intrinsically Safe Detectors 74Orbis IS Detector range 77Intrinsically Safe Audio/Visual Signalling 79

ASPIRATING SMOKE DETECTION

Where to use High Sensitivty Smoke Detection 84How High Sensitivty Smoke Detection works 86SENATOR High Sensitivty Smoke Detection 88HART High Sensitivty Smoke Detection 98Sniffer Pipe 103

ALARMLINE LINEAR HEAT DETECTION

Where to use Alarmline Linear Heat detection 108Alarmline Analogue 110Alarmline Digital Cable 112Alarmline Fixing Accessories 114

ZOOM PRINT EXITPAGE 3/120 www.kfp.co.uk HOME CONTENTS

CONTENTSKidde Fire Protection 2 United Technologies 4UTC Fire and Security 6

Page 4: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 4 5

United Technologies Corporation, based in Hartford, Connecticut, USA, is a diversified industrial company, with 225000 employees in more than 4000 locations worldwide, which serves the commercial building and aerospace industries. UTC’s business units comprise:

CarrierHeating, ventilation, air-conditioning and refrigeration systems; sustainable building solutions for residential, commercial, industrial and transportation applications.

Hamilton SundstrandElectrical power and distribution systems, flight control systems, pilot controls, propulsion systems, environmental control systems and fire protection products for aircraft and military ground vehicles.

OtisDesign, manufacture, installation, and service of elevators, escalators and moving walkways for commercial and residential buildings, multipurpose malls, educational institutions and urban transportation systems.

UNITED TECHNOLOGIES

Pratt & WhitneyEngines for commercial and military aircraft and helicopters; regional, business and light jets. Land-based gas turbine and geothermal power solutions for industrial and utility markets.

SikorskyMilitary and commercial helicopters; fixed-wing aircraft; spare parts and maintenance, repair and overhaul services for helicopters and fixed-wing aircraft.

UTC Fire & SecurityElectronic security and fire safety systems, software and services; design, integration, installation and servicing of access control, intruder alarm, video surveillance, and fire detection and suppression systems; monitoring, response and security personnel services.

UTC PowerFuel cell systems for on-site power applications and transportation.2008

ZOOM PRINT EXITPAGE 4/120 www.kfp.co.uk HOME CONTENTS

Page 5: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 4 5ZOOM PRINT EXITPAGE 5/120 www.kfp.co.uk HOME CONTENTS

Page 6: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 6 7

A global leader in fire safety and security, UTC Fire & Security (UTCFS) delivers peace of mind to individuals and businesses throughout the world.

In fire safety, UTCFS comprises a diverse portfolio of businesses, including residential and commercial portable fire extinguishers, detection & alarm, fire suppression, fire fighting equipment, specialty detection and combustion control.

In electronic security, our companies provide systems integration, installation and service of intruder alarms, access control system, digital video surveillance and recording devices.

UTCFS companies serve a variety of customer segments including education, entertainment, financial services, government, healthcare, petrochemical oil and gas, telecommunications and utilities, marine and many others.

UTC FIRE & SECURITY

Our brands include such well-known names as Angus Fire, Autronica, Chemetron, Det-tronics, Onity, Fenwal, Marioff, Red Hawk, Sicli, and many others. Some of the world’s most discriminating customers rely on UTCFS products, including the Eiffel Tower in Paris; and the historic Waldorf Astoria Hotel, 7 World Trade Center and Statue of Liberty in New York City; Westminster Abbey in London and the Beijing Olympic stadium in China.

ZOOM PRINT EXITPAGE 6/120 www.kfp.co.uk HOME CONTENTS

Page 7: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 6 7ZOOM PRINT EXITPAGE 7/120 www.kfp.co.uk HOME CONTENTS

Page 8: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 8 9

CONTROL PANELS

ZOOM PRINT EXITPAGE 8/120 www.kfp.co.uk HOME CONTENTS

Page 9: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 8 9

Conventional panels:

A simple and cost effective solution for small area applications which require minimal cause and effect, i.e. shops, clinics, schools etc.

Conventional panels operate using zonal principles where detection devices are allocated to a dedicated circuit which will cover a specific area identified as a detection zone.

A fire alarm control panel is the core part of any fire detection system, monitoring detection devices for alarm signals and activating the required sequence of events to ensure safe evacuation, notification to emergency services or operation of fire suppression equipment. Therefore it is important whichever system you select it provides the functionality, flexibility and reliability to ensure optimum performance. Kidde’s range of control panels are designed to meet the highest standards in fire protection.

Intelligent Addressable control panels:

Microprocessor based distributed intelligence enables systems to be tailored to the exact requirements of a wide range of system configurations.

Intelligent addressable control panels operate using detection loops distributed throughout the protected building. Each loop device is provided with a unique address enabling accurate location of a fire.

Extinguishing control panels:

Based around a conventional control panel it is provided with additional features and functionality to control the safe operation of fire suppression systems.

ZOOM PRINT EXITPAGE 9/120 www.kfp.co.uk HOME CONTENTS

Page 10: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

INTELLIGENT ADDRESSABLE FIRE ALARM PANELS

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 10 11

VEGA INTELLIGENT ADDRESSABLE CONTROL PANEL

Vega is an open protocol control panel which is compatible with Apollo XP95/Discovery and Hochiki ESP devices. The Vega panel is expandable from 1 to 16 loops in single loop increments. An 8 line 40 Character LCD allows ease of on site programmability, with clear information relating to fire and fault conditions.

Zonal LED indications for fire and fault support the information provided on the LCD, with the panel available in 24, 56, 88 or 120 zone versions.

Vega incorporates many control features through the keys provided on the front membrane – Silence Buzzer, Silence Alarms, Reset, Delay override, Evacuate and numeric keys 0-9.Three password protected access levels restrict operation and programming of the system to the relevant authorised personnel. A range of software features are provided to minimise the possibility of false alarms including day mode, programmable time delays and investigation timers which allow the user time to investigate the incident before a full alarm is raised.

Monitored sounder outputs and volt free relay outputs are provided on the control panel, the number will vary depending on the number of loops.

Vega supports an extensive range of options including printer facility, repeater panels, plug-in option cards and networking capabilities.

INTELLIGENT ADDRESSABLEFire Alarm PanelsKidde Fire Protections range of addressable control panels represent the ultimate in detection and alarm technology.

Microprocessor based distributed intelligence enables systems to be tailored to the exact requirements of a wide range of system configurations. Offering flexibility in design and operation, Kidde panels are ideal for installation in many applications:

• Hotels• Office complexes• Manufacturing sites• Hospitals• Schools• Residential complexes• Commercial complexes

ZOOM PRINT EXITPAGE 10/120 www.kfp.co.uk HOME CONTENTS

Page 11: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 10 11

Engineer features:

• Forward and reverse loop scan enables easy location of open or short circuit faults• Autolearn allows new loop configurations to be recognised• Panel test enables visual and audible indications to be tested• Device test enables electronic testing of individual loop devices • Output group test enables verification of output programming• Alarm simulation test combines the device and output group test options, to check alarm

cause and effects• Device fault codes assist with fault finding from panel location• Event log stores a maximum of 512 events

The Vega range is provided in a number of standard panel configurations, although the modular configuration of the Vega enables unique panel specifications to be created on request.

Technical specification

No. of detection loops 1-16 Loops, Max current per loop 220mA

Display 8 x 40 Character LCD, backlit with adjustable viewing

Indications 14 Status indications defined by EN45 part 2 Zonal fire and fault indications, 24, 56, 88 and 120 zone options. 64 Plant LED indications (Optional)

Sounder outputs Programmable sounder outputs rated 1 Amp @ 17 to 28.5 Volts dc 1-4 Loop panel – 4 x Sounder circuits 5-8 Loop panel – 8 x Sounder circuits 9-12 Loop panel – 12 Sounder circuits 13-16 Loop panel – 16 Sounder circuits Optional 8 way sounder card available for expansion

Relay outputs Programmable volt free changeover relay contacts rated 1A @ 30V dc 1-4 Loop panel – 4 x Relay contacts 5-8 Loop panel – 8 x Relay contacts 9-12 Loop panel – 12 x Relay contacts 13-16 Loop panel – 16 x Relay contacts Optional 8 way relay card available for expansion

Repeater output Optional repeater card available, RS485 communication

Power supply 110 – 270V ac mains input voltage sensing Temperature monitored battery charging 2.5 Amp, 4 Amp or 8 Amp power supplies available

Current consumption 1 loop control panel - Quiescent: 350mA Alarm: 730mA 4 Loop control panel - Quiescent : 570mA Alarm: 940mA 8 Loop control panel - Quiescent: 800mA Alarm: 1100mA 16 Loop control panel - Quiescent: 1800mA Alarm: 2400mA

Service port RS232 DIN socket for connecting to PC

Physical dimensions 1-4 Loop panel: 500W x 400H x 155D 5-8 Loop panel: 500W x 550H x 225D 9-16 Loop panel: 1000W x 550H x 225D

Enclosure Mild steel, surface mount, Semi gloss ash grey BS4800 00A01 IP rating: 30 20mm pre-formed knockouts top and bottom

ZOOM PRINT EXITPAGE 11/120 www.kfp.co.uk HOME CONTENTS

Page 12: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

INTELLIGENT ADDRESSABLE FIRE ALARM PANELS

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 12 13

Standard panel part numbers:

Vega panel part numbers are a sequence of numbers and letters which detail the panel configuration e.g.

V01/1/024/*/2 1 Loop Vega, 24 Zone, 2.5 Amp power supply

V06/2/056/A/4/P

Denotes the number of loops i.e. V06 is a 6 loop Vega, V02 is a 2 loop Vega etc.

Denotes box size1 = 400 x 500 x 1552 = 550 x 500 x 1553 = 550 x 500 x 2254 = 550 x 1000 x 225

Denotes the panel is fitted with a Thermal Event Printer

Denotes PSU size.2 = 2.5A PSU4 = 4A PSU8 = 8A PSU

Denotes panel protocolA = Apollo XP95/DiscoveryE = Hochiki ESP

Denotes number of Zone indications.024 = 24 Zone indications056 = 56 Zone indications088 = 88 Zone indications120 = 120 Zone indications

Standard panel range

Note: Add ‘A’ for Apollo or ‘E’ for Hochiki ESP in place of the * in the part number.

V01/1/024/*/2/P 1 Loop Vega, 24 Zone, 2.5 Amp power supply, Printer

V01/1/024/*/4 1 Loop Vega, 24 Zone, 4 Amp power supply

V01/1/024/*/4/P 1 Loop Vega, 24 Zone, 4 Amp power supply, Printer

V02/1/024/*/2 2 Loop Vega, 24 Zone, 2.5 Amp power supply

V02/1/024/*/2/P 2 Loop Vega, 24 Zone, 2.5 Amp power supply, Printer

V02/1/024/*/4 2 Loop Vega, 24 Zone, 4 Amp power supply

V02/1/024/*/4/P 2 Loop Vega, 24 Zone, 4 Amp power supply, Printer

V03/1/024/*/2 3 Loop Vega, 24 Zone, 2.5 Amp power supply

V03/1/024/*/2/P 3 Loop Vega, 24 Zone, 2.5 Amp power supply, Printer

V03/1/024/*/4 3 Loop Vega, 24 Zone, 4 Amp power supply

V03/1/024/*/4/P 3 Loop Vega, 24 Zone, 4 Amp power supply, Printer

V04/1/024/*/2 4 Loop Vega, 24 Zone, 2.5 Amp power supply

V04/1/024/*/2/P 4 Loop Vega, 24 Zone, 2.5 Amp power supply, Printer

V04/1/024/*/4 4 Loop Vega, 24 Zone, 4 Amp power supply

V04/1/024/*/4/P 4 Loop Vega, 24 Zone, 4 Amp power supply, Printer

V04/2/056/*/4/P 4 Loop Vega, 56 Zone, 4 Amp power supply, Printer

V05/3/056/*/4/P 5 Loop Vega, 56 Zone, 4 Amp power supply, Printer

V06/3/056/*/4/P 6 Loop Vega, 56 Zone, 4 Amp power supply, Printer

V07/3/056/*/4/P 7 Loop Vega, 56 Zone, 4 Amp power supply, Printer

V08/3/056/*/4/P 8 Loop Vega, 56 Zone, 4 Amp power supply, Printer

V12/4/088/*/8/P 12 Loop Vega, 88 Zone, 8 Amp power supply, Printer

V16/4/120/*/8/P 16 Loop Vega, 120 Zone, 8 Amp power supply, Printer

ZOOM PRINT EXITPAGE 12/120 www.kfp.co.uk HOME CONTENTS

Page 13: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 12 13

VEGA LT

Vega LT intelligent addressable fire alarm control panel provides the same system functionality as the standard Vega panel in a cost-effective package for smaller fire system configurations. Developed using the existing hardware and software platforms of the highly successful Vega range, Vega LT delivers high performance at a competitive price for users who require a one or two loop intelligent addressable panel.

Features• Single loop panel – upgradeable to Two loops• Supports Apollo XP95/Discovery and Hochiki ESP protocols• 8 Line 40 Character display, back lit• 16 Zonal indications• Programmable Alarm and Relay outputs• Compatible with VR3000 repeater panel

Technical specificationNo. of detection loops 1 loop, additional loop can be added

Display 8 x 40 Character LCD, backlit with adjustable viewing

Indications Status indications defined by EN54 part 2, 16 x Zone indications

Sounder outputs 2 x Programmable sounder outputs rated 1 Amp @ 24 Volts dc nominal Relay outputs 2 x Programmable volt free changeover relay contacts rated 1A @ 24V dc

Repeater output Optional repeater card available, RS485 communication

Power supply 2.5 Amp @ 24V dc 110 – 270V ac mains input voltage sensing Temperature monitored battery charging

Current consumption Quiescent: 350mA Alarm: 730mA

Service port RS232 DIN socket for connecting to PC

LT2000 Single loop control panel – Apollo protocol

LT2001 Single loop control panel – Hochiki protocol

VEGA OPTION CARDMOTHERBOARD

Vega motherboards can be installed within the Vega control panel or located remotely in a Vega interface enclosure. Each motherboard allows up to 4 plug-in option cards to be connected to the Vega control panel. Up to 4 motherboards can be connected to a single Vega control panel providing slots for up to 16 plug-in option cards in total.

44782-K091 Vega option card motherboard

44782-K092 Vega 8 way relay output card

VEGA 8 WAY RELAY OUTPUT CARD

This card provides additional programmable volt free relay outputs on the Vega control panel. Volt free relay contacts can be used to either operate other equipment i.e. to close fire dampers etc or provide alarm signalling to other systems such as a BMS.

Relay outputs are rated 1 Amp @ 30V dc and can be individually configured as normally open or normally closed in operation.

VEGA 8 WAY MONITORED OUTPUT CARD

This card provides an additional 8 individually programmable monitored outputs which can be used for operating audible and visual devices, as well as solenoid devices. Each output is individually fused and rated 1 amp at 28 volts dc.

44782-K093 Vega 8 way monitored output card

ZOOM PRINT EXITPAGE 13/120 www.kfp.co.uk HOME CONTENTS

Page 14: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

INTELLIGENT ADDRESSABLE FIRE ALARM PANELS

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 14 15

VEGA REPEATER PANELS

To complement the Vega control panels, a versatile range of repeaters are available which will allow remote indication and operation of the fire alarm system.

Repeaters are provided with an 8 line 40 character LCD and with or without zonal indications. They can be configured as passive (without user controls) or Active (with user controls) a maximum of 64 repeaters can be connected to a single Vega control panel of which 15 can be active and 49 can be passive.

Note: Controlling Vega panel must be fitted with repeater output card.

Features:• 24, 56, 88 and 120 zone indication variants• Integral power supply• Alarm sounder output• Volt free changeover relay contacts for Fire and Fault conditions• Internal panel buzzer• Status indications• Active repeater controls: Silence, Reset, Delay Override, Silence

Alarms, Evacuate, Scroll, Numeric keys, Cursor keys

• Optional event printer

Technical specificationDisplay 8 x 40 Character LCD, backlit with adjustable viewing

Indications 14 Status indications defined by ENS4 part 2 Zonal fire and fault indications, 24, 56, 88 and 120 zone options.

Sounder outputs 1 x Sounder output rated 1 Amp @ 17 to 28.5 Volts dc

Relay outputs Fire and Fault volt free changeover relay contacts rated 1A @ 30V dc

Power supply 2.5 Amp power supply 110v – 270v ac mains input, voltage sensing

VEGA 16 WAY NON-MONITORED INPUT CARD

This card provides 16 individually programmable non-monitored inputs. These inputs provide the facility for monitoring the operation of switched contacts either from a relay or a keyswitch. Each input of the card requires a 0 volt to be either applied or removed for activation, this can be selected individually for each input using DIL switches on the PCB.

44782-K094 Vega 16 way non-monitored input card

44782-K095 Vega 16 way non-monitored output card

VEGA 16 WAY NON-MONITORED OUTPUT CARD

This card provides 16 individually programmable open collector outputs. Commonly used for driving LED’s on a mimic panel, they can also be used to trigger the switching of relays. Each output of the card provides 0-volt signal on activation.

VEGA 8 WAY MONITORED INTPUT CARD

This card provides 8 individually programmable monitored inputs. The inputs can be used for monitoring zones of conventional detectors as well as any devices which provide a volt free switched output.

44782-K096 Vega 8 way monitored input card

ZOOM PRINT EXITPAGE 14/120 www.kfp.co.uk HOME CONTENTS

Page 15: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 14 15

VR3120 Repeater LCD 120 Zonal indications

VR3120P Repeater LCD 120 Zonal indications with printer

VEGA OPTIONAL ACCESSORIES

VEGA INTERFACE BOXESTwo interface boxes are available which can be used to house Vega motherboards and plug-in option cards. This allows the boards to be installed up to 1km from the Vega control panel.The interface boxes are provided in two sizes accommodating either 2 or 4 Vega motherboards.

Dimensions: 500W x 400H x 155D 500W x 550H x 225D

VN4155 Vega Interface box c/w space for 2 x Motherboards

VEGA FLUSH MOUNTING BEZELSA range of flush mounting bezels are available to fit Vega control panels, repeaters and interface enclosures. The bezels allow the enclosures to be recessed into a wall providing an aesthetically pleasing installation for reception areas, foyers etc.

Bezels are manufactured from mild steel, paint colour is semi gloss ash grey to match the enclosures.

35100-K099 Flush mounting bezel to fit enclosure 500W x 550H

Current LCD only repeater - Quiescent 90mA Alarm 120mA Zonal repeater - Quiescent 120mA Alarm 170mA

Physical dimensions LCD only repeater- 550W x 280H x 140D 24 Zone repeater - 500W x 400H x 140D 56 Zone repeater - 500W x 550H x 140D 88 Zone repeater - 500W x 700H x 140D 120 Zone repeater - 500W x 850H x 155D

Enclosure Mild steel, surface mount, Semi gloss ash grey BS4800 00A01 IP rating: 30 20mm pre-formed knockouts top and bottom

VR3088 Repeater LCD 88 Zonal indications

VR3088P Repeater LCD 88 Zonal indications with printer

VR3056 Repeater LCD 56 Zonal indications

VR3056P Repeater LCD 56 Zonal indications with printer

VR3024 Repeater LCD 24 Zonal indications

VR3024P Repeater LCD 24 Zonal indications with printer

VR3000 Repeater LCD Only

VR3000P Repeater LCD Only with printer

VN5225 Vega Interface box c/w space for 4 x Motherboards

35100-K080 Flush mounting bezel to fit enclosure 500W x 400H

35100-K098 Flush mounting bezel to fit enclosure 500W x 250H

VEGA REPEATER OUTPUT CARD

To enable the Vega repeaters to communicate with the Vega control panels a repeater output card is required. This card plugs into the Vega Master Basic Loop Controller and provides the RS485 communications to the repeater panels.

44782-K076 Vega Repeater Output card

ZOOM PRINT EXITPAGE 15/120 www.kfp.co.uk HOME CONTENTS

Page 16: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

INTELLIGENT ADDRESSABLE FIRE ALARM PANELS

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 16 17

VEGA Networking SystemsWhere a fire system or site installation demands the use of more than one Kidde Vega panel, a communication network link can provide the tailor made engineering solution for most applications, from a simple two panel system to a multi-panel networked site-wide installation.

Kidde offers two types of network to compliment its Vega range:

• Common Zone Networking (CZN)• VegaNET

VEGA CONFIGURATION SOFTWARE

Viper is a software programme required for configuring the Vega control panel. A number of versions are available depending on the version of processor software installed in the Vega panel. All panels are despatched with a CD containing the current Viper software. It is recommended before using Viper to check with our technical department that you have the correct version to suit your control panel.

This software is compatible with Windows versions up to Windows Xp.

D28300-3xx Viper software

D28320-1xx Viper software for Vega CZN panels

Note: xx would be replaced by the version number

VEGA COMMON ZONE NETWORKING (CZN)

Common Zone Network (CZN) enables up to 32 Vega stand alone systems to be connected together providing site wide fire alarm monitoring for small, medium and large sized establishments or multi-building sites.

CZN supports the full range of Vega control panels providing a flexible approach to system design that can address the many different alarm reporting, and evacuation strategies required for buildings of today.

CZN integrated solution, provides the site fire team or designated personnel with instantaneous location of fire alarm incidents saving valuable search and response time.

CZN concept is based upon a shared common zone principle, where the maximum number of geographical fire compartment zones does not exceed 120. The system configuration can be programmed to conform to two basic operating applications.

ZOOM PRINT EXITPAGE 16/120 www.kfp.co.uk HOME CONTENTS

Page 17: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 16 17

VEGA CZN NETWORK OPTION

Vega panels can easily be upgraded on site to provide a CZN network by installation of the Vega CZN network option. This consists of a ‘527’ network card including latest software EPROM, mounting plate, cable harnesses and upgrade software EPROM’s for the panel Main Control Processor.

VN2105 Vega CZN network option – Vega

VN2108 Vega CZN network option – Vega LT

• Master\Slave – satellite panels display local information and transmit alarm data to master panels, which display site wide alarm information.

• Multi-Master – each satellite panel displays site wide alarm information.

Features• Up to 32 Vega panels form a site network• 120 site wide ‘Fire’ zones incorporating zone offset facility• 64 site wide ‘Plant’ indications• BGU override and co-incidence voting between panels• Comprehensive site wide cause and effect control• Isolate zones and common output groups from any panel on the network• RS422 Communications allow up to 1 Km between control panels

CZN EXAMPLE

ZOOM PRINT EXITPAGE 17/120 www.kfp.co.uk HOME CONTENTS

Page 18: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

INTELLIGENT ADDRESSABLE FIRE ALARM PANELS

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 18 19

VEGANET DISPLAY SYSTEM

VegaNET Display System is a PC Windows™ based application designed primarily for the monitoring of fire alarm systems. VegaNET provides the user with a means to view the entire system enabling rapid recognition, identification of source and extent of each event, particularly during multiple alarm conditions. The presentation of alarm information is provided in a simple, standard text or graphical format, giving operators the right information on which to make appropriate decisions.

VegaNET Display System is designed specifically for connecting to the Kidde range of fire detection panels providing full interrogation of sophisticated features. Powerful network cards located within each fire control panel enable up to 32 remote panels to be supervised. This provides the operator with an instantaneous overview of all systems with immediate access to detailed information as required. Alternatively, using network outstations incorporated within the system design, monitoring of third party equipment via discrete digital inputs can be achieved.

VegaNET Display System provides central control and monitoring for remote sector nodes using full-duplex transfer of information, status and commands over a networked system.The system allows each alarm device or input to be allocated a priority, which ensures that the operator is presented with the most urgent high priority alarms, followed by those of lesser importance. Monitoring of non fire related events such as plant, security, and process are also catered for by the system.

Features• Available as Text or Graphic versions• Prominent user controls with attractive appearance• Print graphical pages with automatic event logging• Multi-level password protection• Unlimited number of graphical pages• Language text translations• Up to 32 (Nodes) Vega panels or outstations per network• Up to 6 computers running VegaNET connected to network• Up to 6 network repeaters and geographic mimics• Can connect 6 networks together providing 192 node capability

VEGANET EXAMPLE

ZOOM PRINT EXITPAGE 18/120 www.kfp.co.uk HOME CONTENTS

Page 19: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 18 19

VEGANET IN ACTION

VN3000 VegaNET Display system package – Text reporting

VN3001 VegaNET Display system package – Graphics reporting

VEGANET DISPLAY SYSTEMS TERMINALS

A complete package containing everything needed to provide a VegaNET text or graphic reporting terminal.This package includes:

• Computer pre-installed with VegaNET Text or Graphics reporting softwarePC minimum specification: Intel Pentium 4, 3Ghz processor, 1GB 533Mhz DDR2SDRAM memory, 160Gb Hard Disk Drive, 17” Flat panel monitor, DVD +/-RW drive, USB keyboard and mouse, Serial and Parallel ports & PS2 adaptor, Windows XP operating system

• Text or Graphic reporting system application CD and run time module• Deskjet printer• Network Control Unit

Note: The specification of the PC and its ancillaries are subject to change without notification

VegaNET software can be purchased separately

VN2000 VegaNET text reporting software

VN2101 VegaNET graphics reporting software

Overview pageShowing location of building in alarm

Level 1 pageShowing building floor level in alarm

Level 2 pageDefining location of detector in alarm

Text message windowProvides device location user intervention details

Sector interrogate facilityEnables user to control remote sector panels

ZOOM PRINT EXITPAGE 19/120 www.kfp.co.uk HOME CONTENTS

Page 20: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

INTELLIGENT ADDRESSABLE FIRE ALARM PANELS

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 20 21

VEGANET NETWORK OPTION

Vega panels can easily be upgraded on site to provide a VegaNET network by installation of the VegaNET network option. This consists of a ‘527’ network card including latest software EPROM, mounting plate, cable harnesses and upgrade software EPROM’s for the panel main control processor.

VN2107 VegaNET Network option – VEGA LT

VN2109 VegaNET Network repeater

VEGANET NETWORK REPEATER

Network repeaters provide simple, high priority alarm text messages for an entire VegaNet network of fire alarm panels or outstations. Up to 6 network repeaters can be connected to the VegaNet network system. The repeaters can be extended to support open collector outputs for LED mimic displays. The Network repeater can be configured with or without user controls and has an optional printer.

Technical specificationDisplay 8 Line 40 Character LCD

Sounder circuits 4 x Common sounder circuits, rated 1 Amp @ 24V dc will activate on any alarm

Relay outputs 4 x Volt free changeover contacts, rated 1 Amp @ 24V dc will activate on any alarm

Power supply 2.5 Amp @ 24V dc 110 – 270V ac mains input voltage sensing Temperature monitored battery charging

Enclosure Surface mount mild steel, Semi gloss ash grey, IP30

Dimensions 500W x 400H x 155D

VN2109P VegaNET Network repeater with printer

VEGANET NETWORK CONTROL UNIT

For each PC running VegaNET software a Network Control Unit is required to interface the PC to the Vega panel network.

Technical specificationPower supply input 85-264Vac, 47-440Hz

Enclosure Surface mount mild steel, Semi gloss ash grey

Dimensions 440W x 226H x 115D

VN2100 VegaNET Network Control Unit

VN2104 VegaNET Network option – VEGA

ZOOM PRINT EXITPAGE 20/120 www.kfp.co.uk HOME CONTENTS

Page 21: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 20 21

VN2103 VegaNET Radial Expander

VEGANET RADIAL EXPANDER

The Radial Expander has been designed to enable network communications to be spurred allowing site cabling to be reduced. This unit can also be used as a line booster to increase the communication cable distance between network cards by a further 1km. There is no limit to the quantity of Radial Expander units that can be accommodated within one system design. The Radial expander allows a single network input to be spurred into 4 network outputs.

Power supply 2.5 Amp @ 24V dc 110 – 270V ac mains input voltage sensing Temperature monitored battery charging

Enclosure Surface mount mild steel, Semi gloss ash grey, IP30

Dimensions 440W x 266H x 115D

VEGANET NETWORK OUTSTATION

It is possible to monitor third party equipment via discrete digital inputs across a VegaNET network. The network outstation is an interface enclosure containing a network card Vega Motherboard and either monitored or non-monitored input cards. Signals can be monitored via the input cards and transmitted across the VegaNET network.

VegaNET network outstations are custom built on request.

ZOOM PRINT EXITPAGE 21/120 www.kfp.co.uk HOME CONTENTS

Page 22: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

INTELLIGENT ADDRESSABLE FIRE ALARM PANELS

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 22 23

AUTROPRIME

The Fire Alarm Control Panel supports 2 detection loops and most Autrosafe detectors, several types of I/O devices for monitored outputs, open collector outputs, galvanic isolated inputs and monitored inputs. All loop units can be mixed freely and connected at any point on the same detection loop. A maximum of 8 additional panels can be freely mixed and connected to the Fire Alarm Control Panel via the RS-485 panel bus, including Repeater Panels, Information Panels, Fire Brigade Panels and Mimic Drivers.

The panel is menu operated on an 8-line display, with 40 characters per line.The Operator Panel, which is an integrated part of the Autroprime panel, can also be mounted separately outside the cabinet.

Autroprime complies with C.E.N. EN 54 regulations, FM regulations (Factory Mutual).

Features• SelfVerify function for automatic testing of detectors• Automatic setup• Automatic addressing of detectors• Two loops• USB for data transfer to/from memory stick• User-friendly display and operator controls• Back-lit operating buttons. Text display suitable for night-time operation• Surface mounting• Designed to meet EN 54 requirements and conforms to CE standards• Complies with environmental conditions of IEC-721-3-3 class 3k5

Autroprime Interactive Fire Detection System is a stand-alone fire detection system for small-to-medium sized applications. Autroprime brings simplicity, quality, cost-effectiveness and extensive functionality in one integrated system.

Plug and playAutroprime is provided to the user in a pre-configured state. In this state the panel is set to automatically recognise detectors and other loop units connected to the detection loops and the availability of routing equipment, etc. As such, the system is fully functional and ready-to-use after a few minutes, simply by turning the power ON. Further site-specific configuration can easily be performed if necessary.

The system uses SelfVerify functionality to ensure that the system will work according to regulations every single day. Furthermore, the system will inform the user when detectors need maintenance, ensuring optimised life-cycle cost. BUR-200 Autroprime Mimic Driver

BU-210 Autroprime Fire Brigade Panel

BV-210 Autroprime Information Panel

BS-200 Autroprime Fire Control Panel

BS-211 Autroprime Repeater Panel

®

ZOOM PRINT EXITPAGE 22/120 www.kfp.co.uk HOME CONTENTS

Page 23: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 22 23

AUTROPRIME LOOP INTERFACES

BN-201 Monitoring input unit

BN-300 Fire Alarm input unit with self verify

BN-310 Relay output unit with self verify

BNA-320/02 Interface board for BN310

BN-320 I/O unit with self verify

BN320/2 Door control unit with self verify

BN-320/4 Monitoring and control unit with self verify

BN-320/5 Sprinkler control system with self verify

BN-330 Interface for conventional detection loops with self verify

BN-500/EX Input unit for Zone 0, 1 & 2 with self verify

BN-40A/3 Loop interface unit for Autrobeam 100 with self verify

BNA-320-01 Interface board for BN-40A/3

BNB-300/32 Interface module

BW-200 Disable unit with push buttons

BW-201 Disable unit with timer input

BU-200 Remote alarm control unit

BZ-500 Ex-barrier unit, Exia IIC

AUTROPRIME DETECTORS

BDH-200 Heat detector

BDH-300 Heat detector with self verify

BDH-500 Heat detector, Self verify, IP44D, environmentally sealed

BD-501 Heat detector inc. base, Self verify, IP56

BDH-500/EX Heat detector, Self verify, IP44D for use in Ex areas, environmentally sealed

BHH-200 Optical smoke detector

BHH-300 Optical smoke detector with Self verify

BHH-500 Optical smoke detector with Self verify, High risk version

BHH-500/EX Optical smoke detector with Self verify, Exi version

BHH-220 Multisensor detector

BHH-320 Multisensor detector with self verify

BHH-520 Multisensor detector with self verify, High risk version

BHH-520/EX Multisensor detector with self verify, Exi version

BHH-502/N Multisensor detector with self verify, Ex zone 2 use only

ZOOM PRINT EXITPAGE 23/120 www.kfp.co.uk HOME CONTENTS

Page 24: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

INTELLIGENT ADDRESSABLE FIRE ALARM PANELS

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 24 25

AUTROPRIME MANUAL CALL POINTS

BF-300 Manual Call Point with self verify

BF-300M/N Manual Call Point with self verify, Ex zone 2

BF-500/EX Manual Call Point with self verify, Exi version

BF-501 Manual Call Point with self verify, IP66, without LED

BF-501/EX Manual Call Point with self verify, IP66, Exi version

BF-501/N Manual Call Point, IP66, Ex zone 2

BF-502 Manual Call Point with self verify, IP66

BF-502/EX Manual Call Point with self verify, IP66, Exi version

BF-502/N Manual Call Point with self verify, IP66, Ex zone 2

AUTROPRIME ADDRESSABLE AUDIO/VISUAL DEVICES

BBR-130 Base sounder, Red, 90dBA

BBR-230 Sounder, Red, 100dBA

BBR-230/IP Sounder, Red, IP65, 100dBA

BBQ-130 Base sounder with beacon, 90dBA

BBQ-230 Sounder/Beacon, Red, I00dBA

BBQ-230/IP Sounder/Beacon, Red, IP65, 100dBA

AUTROPRIME INSTALLATION ACCESSORIES

BWA-101 Detector base with microswitch

WBW-100 Coupling unit for detector base

WBW-101 Detector mounting plate for false ceiling

BWP-145 Detector base with heat element

BWP-100/20 Conduit box 4 x M20

BWP-100/25 Conduit box 4 x M25

BPW-143/150 Canal adaptor 150mm inc. socket

BPW-143/300 Canal adaptor 300mm inc. socket

BPW-143/550 Canal adaptor 550mm inc. socket

ZOOM PRINT EXITPAGE 24/120 www.kfp.co.uk HOME CONTENTS

Page 25: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 24 25

CUSTOM DESIGNControl panelsMeeting our customers requirements is imperative when it comes to fire alarm systems. For over 15 years Kidde have supplied custom design panels based around our standard range of equipment.

3 x Custom built Vega control panels in a 2m high 19” rack type cabinet. Each panel has 16 detection loops, 120 detection zones, 4 x 8 way sounder cards, 4 x 8 way relay cards and event printer. Designed for a Power Station project.

Custom designed panels supplied on previous projects include:

• Special colour control panels• Geographic LED mimics• 19” Rack mount panels• Floor standing enclosures incorporating fire and gas detection control systems• Combined fire detection and multi –area suppression control panels

If you have a special requirement, then it will be necessary to contact your sales representative who will be more than happy to discuss your requirements with you.

ZOOM PRINT EXITPAGE 25/120 www.kfp.co.uk HOME CONTENTS

Page 26: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

INTELLIGENT ADDRESSABLE FIRE ALARM PANELS

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 26 27

CONVENTIONALFire Alarm PanelsConventional Fire Alarm control panels provide cost effective fire engineering solutions for small area applications which require minimal cause and effect:

Shops, Clinics, Schools, Telecommunications

Conventional systems are wired as circuits or ‘zones’ with a zone being an area of maximum 2000m2, panels are supplied with a varying number of detection zones.

Detection devices connected to the detection zone circuits operate on a simple two state basis, either ‘on’ or ‘off’ i.e. ‘Alarm’ or ‘No alarm’. The conventional control panel monitors the state of these devices, determines whether the device is in alarm and provides a general alarm signal to operate visual and audible warning devices to notify personnel within the building. The Kidde Sirius II conventional fire alarm control panel has been designed with simplicity of operation and attractive appearance in mind. Sirius II is compatible with a wide range of detectors making it ideal for retro-installations.

Features:

• Integral zone detector removal with short and open circuit monitoring (no AEOL device)• Code access (No keys to lose)• Wide range of detectors supported i.e. Apollo, Hochiki and Nittan• A wide range of warning devices supported e.g. electronic sounders, bells, beacons etc.• Each zone supports up to 32 detectors and unlimited number of call points• 2 x alarm circuits as standard, rated 1 A @ 28 V dc• Fire and Fault relay outputs• 1 x Monitored Fire Output with disable function rated 0.5 A @28 V dc*• Integral 2.5A Switch Mode Power Supply incorporating intelligent battery monitoring• One man walk test• Zone disable function• Programmable zone co-incidence• Programmable sounder functions• Real time clock /alarm counter• RS485 Repeater network*

* not available on 2 zone variant

SIRIUS II CONVENTIONAL FIRE ALARM CONTROL PANEL

A cost effective fire alarm control panel approved to EN54 parts 2 and 4. The Sirius II is available in 2, 4 or 8 Zone options. User friendly operation allows the panel to be configured through the membrane keys. LED indications and an LCD provides clear information regarding the panel status. The Sirius II has a range of accessories including repeaters and option cards to provide flexibility in system design.

SE8000 Sirius II 8000 - 8 Zone panel

SE4000 Sirius II 4000 - 4 Zone panel

SE2000 Sirius II 2000 - 2 Zone panel

ZOOM PRINT EXITPAGE 26/120 www.kfp.co.uk HOME CONTENTS

Page 27: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Features:

• 8 Zonal fire indications• RS485 communication with control panel• Common Fire and Fault relay outputs• 18-28V dc supply• Power Supply Monitor fault input• Switched 0v Zonal outputs• User controls – Silence/Resound Alarms, Panel Reset, Silence Buzzer, Delay Override,

Panel access

SIRIUS II REPEATER PANEL

Sirius II Repeater panel provides remote indication and controls for the Sirius II, 4 and 8 zone conventional fire alarm panels. Repeater panels can be configured as passive (indication only) or active (Indication and minimal controls), up to 7 active and 7 passive repeaters can be connected to a Sirius II control panel.

SR8500 Sirius II Repeater panel

• 8 monitored outputs• RS485 Communications• Up to seven boards connected to a single panel• Fault relay output

SIRIUS II 8-WAY SOUNDER OUTPUT BOARD

Sirius II 8-Way Sounder Output board provides the facility to expand the number of sounder circuits on a Sirius II control panel. The Sounder board is compatible with the 4 and 8 zone variants only. Each sounder circuit is rated at 250mA, and is provided with an LED indication to show operation.

44782-K173 Sirius II 8-Way Sounder Output board

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 26 27ZOOM PRINT EXITPAGE 27/120 www.kfp.co.uk HOME CONTENTS

Page 28: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

INTELLIGENT ADDRESSABLE FIRE ALARM PANELS

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 28 29

The relay outputs can be configured for various panel conditions:

Zonal FireZonal Fault – Non latchingZonal Fault – LatchingZone DisabledPanel outputsClear processor fault

When configured for panel outputs the relays will be individually allocated to indicate the following status conditions:

Output 1 - General FireOutput 2 - General FaultOutput 3 – General TestOutput 4 – General DisablementOutput 5 – Silence AlarmsOutput 6 – System resetOutput 7 – EvacuateOutput 8 – Class change

• 8 Relay outputs, rated 1A• RS485 Communications• Up to 7 boards can be connected to a single panel• Fault relay output

SIRIUS II 8-WAY RELAY OUTPUT BOARD

Sirius II 8-Way Relay Output board provides the facility to expand the number of relay outputs on a Sirius II control panel. The relay output board is compatible with the 4 and 8 zone variants only.

44782-K174 Sirius II 8-Way Relay Output board

• RS485 Communications• Fault relay output • Output relays, rated 1A

SIRIUS II INPUT/OUTPUT BOARD

Sirius II Input/Output board provides eight monitored inputs and eight corresponding volt free relay outputs. The inputs can be used to monitor the status of other equipment within the site, on receiving a signal from the monitored circuit the corresponding output can be operated which can be used for signalling or operation of other equipment.

The outputs can be set to operate in either of two modes, Mode 1 – On input circuit active, Mode 2 – On input circuit fault. LED’s are provided to indicate the status of the individual inputs and outputs.

44782-K175 Sirius II Input/Output board

ZOOM PRINT EXITPAGE 28/120 www.kfp.co.uk HOME CONTENTS

Page 29: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

EXTINGUISHINGControl SystemsThe FireBeta XT, XT+ and ECU are the latest range of extinguishing control systems from Kidde. The range covers single area and multi-area extinguishing systems with the following:

FireBeta XT Compliant to EN12094-1 provides three detection zones with single area extinguishing controls.

FireBeta XT+ Is a modular system consisting of a detection module approved to EN54 parts 2 and 4 and up to 4 extinguishing modules compliant to EN12094-1.

FireBeta XT+ ECU Is a single area extinguishing module compliant to EN12094-1 which can be connected to an already installed conventional or addressable fire alarm control panel providing the controls for an extinguishing system.

Along with the range of FireBeta XT status indicators and the FireBeta XT Ancillary board they provide a wide selection of options for many different applications.

All extinguishing control systems are suitable for use with the full range of Kidde engineered fire suppression systems incorporating 3M™ Novec™ 1230 Fire Protection Fluid, FM-200®, Argonite® inert gas and Carbon Dioxide.

Technical specification

Mains supply 230V ac, 50Hz +10% - 15% (100 Watt maximum)Power supply rating 3 Amp total including battery charge 28vBattery capacity 2 x 12v 7ah SLA batteriesSounder outputs 21 to 28V dc, 500mA electronic fuse – Detection sounders S1 & S2, 2nd stage sounder.Relay outputs 5 to 30V dc, 1 Amp maximum – Common fault, local fire, fire, 1st stage alarm, 2nd stage alarm and extract outputs.Remote inputs switched 0v inputs – Silence, Reset, Alarm and FaultExtinguishing output 1 Amp maximum load for 5 minutes, voltage reversing dcDimensions 385W x 310H x 90D

FIREBETA XT 3+1

FireBeta XT 3+1 is a single area extinguishing control panel. Three detection zones and one extinguishant release area can be configured to activate from any single zone, any two zones from three or activation of all three zones.

An LED display is provided to enable easy configuration, the display also provides visual indication of the time remaining until extinguishant release.

The FireBeta XT provides monitored circuits for low pressure switch, release pressure switch, manual release, hold, and mode select features.

Relay outputs are provided for transmitting alarms and fault, additional status relays can be provided using the ancillary output PCB.

Mode select keyswitch and manual release controls are provided on the fascia panel.

Up to seven ancillary output boards and seven status indicator units can be connected to the FireBeta using RS485 communications.

The FireBeta XT can be easily configured for use with intrinsically safe detection and alarm devices.

23911-K069 FireBeta XT 3+1

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 28 29ZOOM PRINT EXITPAGE 29/120 www.kfp.co.uk HOME CONTENTS

Page 30: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

INTELLIGENT ADDRESSABLE FIRE ALARM PANELS

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 30 31

23911-K087 FireBeta XT+ (4+1) - 4 detection zones, 1 extinguishing area

23911-K085 FireBeta XT+ (4+2) - 4 detection zones, 2 extinguishing areas

23911-K088 FireBeta XT+ (8+2) - 8 detection zones, 2 extinguishing areas

23911-K089 FireBeta XT+ (8+3) - 8 detection zones, 3 extinguishing areas

23911-K090 FireBeta XT+ (8+4) - 8 detection zones, 4 extinguishing areas

Technical specification

Mains supply 230V ac, 50Hz +10% - 15% (100 Watt maximum)Power supply rating 2 area units - 3 Amp total including battery charge 28v 3 & 4 area units – 4 Amp total including battery charge 28vBattery capacity 2 x 12v 12ah SLA batteriesSounder outputs 21 to 28V dc, 500mA electronic fuse – Detection module sounders S1

& S2, Extinguishing module sounders 1st stage & 2nd stage alarm.Relay outputs 5 to 30VDC, 1 Amp maximum – Common fault, local fire, fire, 1st stage alarm, 2nd stage alarm, Released, Aborted and extract outputs.Remote inputs switched 0v inputs – Silence, Reset, Alarm and FaultExtinguishing output 2 x outputs - 1 Amp load for 5 minutes or 3 Amps for 20 millisecondsDimensions 1 & 2 area units 385W x 520H x 110D 3 & 4 area units 385W x 700H x 110D

FIREBETA XT+

FireBeta XT+ is a range of multi area extinguishing control panels. The FireBeta XT+ consists of a detection module with 4 or 8 detection zones and up to 4 individual extinguishing release modules.

The detection module provides all the controls and indications required for fire detection, including outputs for common fire, fault, and common sounder outputs. The detection module communicates with the extinguishing release modules using RS485 communications allowing the detection zones to be configured to activate individual release modules.

Each extinguishing module is provided with an LCD giving clear information relating to status and enables easy configuration.

The extinguishing modules each provide monitored circuits for low pressure switch, release pressure switch, manual release, hold, and mode select features.

Relay outputs are provided for transmitting alarms and fault, additional status relays can be provided using the ancillary output PCB.

Two actuator outputs are provided on each extinguishant module which can be configured for common mode or main and reserve operation.

A mode select keyswitch and manual release controls are provided on each release module.

Up to seven ancillary output boards and seven status indicator units can be connected to the FireBeta using RS485 communications.

The FireBeta XT+ can be easily configured for use with intrinsically safe detection and alarm devices.

ZOOM PRINT EXITPAGE 30/120 www.kfp.co.uk HOME CONTENTS

Page 31: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Technical specification

Mains supply 230V ac, 50Hz +10% - 15% (100 Watt maximum)Power supply rating 4 Amp total including battery charge 28vBattery capacity 2 x 12v 7ah SLA batteriesSounder outputs 21 to 28V dc, 500mA electronic fuse - 1st stage & 2nd stage alarm.Relay outputs 5 to 30VDC, 1 Amp maximum – Fault, 1st stage alarm, 2nd stage alarm, Released, Aborted and Extract outputs.Remote inputs switched 0v inputs – Silence, Reset, Alarm and FaultExtinguishing output 2 x outputs - 1 Amp load for 5 minutes or 3 Amps for 20 millisecondsDimensions 385W x 310H x 90D

FIREBETA XT ECU

FireBeta XT ECU is a single area extinguishant release module which can be connected to a conventional or addressable control panel to provide an extinguishing control system. The ECU is provided with two fully monitored inputs which can monitor outputs from a control panel used to trigger the extinguishing release module. ECU is provided with an integral 4 Amp PSU and space for 2 x 12v 7Ah SLA batteries. Relay outputs provided for common fire, fault, 1st and 2nd stage alarm. Sounder outputs provided for common, 1st and 2nd stage alarms. Dual extinguishing outputs are provided for main and reserve operation.

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 30 31

FIREBETA Status Indicators

To complement the FireBeta XT, XT+ and ECU control units, a range of System Status Indicators are available. Up to seven Status Indicators can be connected to each extinguishing area, through a serial bus connection. Status Indicators are fully supervised and fault conditions will be indicated on the associated control panel should any unit become disconnected.

The status indicators are available with the following options:

• Indicator only• Indicators and Auto/Manual keyswitch• Indicators, Auto/Manual keyswitch and Manual Release

pushbutton• Flush Mounting options• Weatherproof options

23911-K086 FireBeta XT ECU

ZOOM PRINT EXITPAGE 31/120 www.kfp.co.uk HOME CONTENTS

Page 32: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

INTELLIGENT ADDRESSABLE FIRE ALARM PANELS

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 32 33

23911-K073 Status Indicator - 6 LEDs & mode select key switch, surface mount 186W x 132H x 50D

STATUS INDICATORINDICATORS AND MODE KEYSWITCH

As well as the 6 status LED’s and the 7 segment LED display this unit is provided with a Mode keyswitch which allows the user to select between Auto/Manual or Manually only extinguishing modes. In auto/manual mode extinguishing release can be activated by the automatic smoke detection or the manual operation of a release unit. Manual only mode will allow extinguishing release by manual operation of a release unit only.

The unit is available as either surface or flush mounting.

23911-K074 Status Indicator - 6 LEDs & mode select key switch, flush mount 210W x 156H x 50D

23911-K075 Status Indicator - 6 LEDs, mode select key switch and manual release, surface mount 186W x 132H x 50D

STATUS INDICATORINDICATORS, MODE KEYSWITCHAND MANUAL RELEASE

As well as the indicators and the mode keyswitch this unit is provided with a Manual Release pushbutton which allows the user to manually activate the release of the extinguishing gas remotely. The manual pushbutton is two stage operation, a pull down plastic flap reveals the pushbutton. The unit is available as either surface or flush mounting.

23911-K076 Status Indicator - 6 LEDs, mode select key switch and manual release, flush mount 210W x 156H x 50D

23911-K071 Status Indicator - 6 LEDs, surface mount 186W x 132H x 50D

23911-K072 Status Indicator - 6 LEDs, flush mount 210W x 156H x 50D

STATUS INDICATOR INDICATION ONLY

The indication only status indicator provides 6 LED’s for remote indication of the following functions:

• Auto/Manual mode• Manual mode• Hold activated• Disabled• Gas release imminent• Gas released

A seven segment LED display is also provided to show the time remaining until gas release.The unit is available as either surface or flush mounting.

ZOOM PRINT EXITPAGE 32/120 www.kfp.co.uk HOME CONTENTS

Page 33: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

STATUS INDICATOR10 LEDs, MODE KEYSWITCH AND MANUAL RELEASE

This status indicator is only compatible with the FireBeta XT (3+1) extinguishing control panel. 4 additional LED’s are provided on the status indicator for indicating the alarm status of the three detection zones as well as a common fault indication.

23911-K077 Status Indicator - 10 LEDs, mode select key switch and manual release, surface mount 186W x 132H x 50D

23911-K078 Status Indicator - 10 LEDs, mode select key switch and manual release, flush mount 210W x 156H x 50D

WEATHERPROOFSTATUS INDICATOR

The range of status indicators are also available in an IP65 weatherproof enclosure.

23911-K081 Weatherproof Status Indicator - 6 LEDs & mode select key switch and manual release, surface mount IP65 - 256W x 169H x 76D

23911-K082 Weatherproof Status Indicator - 10 LEDs & mode select key switch and manual release, surface mount IP65 - 256W x 169H x 76D

23911-K079 Weatherproof Status Indicator - 6 LEDs, surface mount IP65 - 256W x 169H x 76D

23911-K080 Weatherproof Status Indicator - 6 LEDs & mode select key switch, surface mount IP65 - 256W x 169H x 76D

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 32 33

FIREBETA XT ANCILLARY BOARD

Compatible with the FireBeta XT, XT+ and ECU control units the Ancillary Board fulfils the requirements to extend signals from the extinguishing system for additional plant control or other signaling applications, such as BMS system interface or house fire alarm systems.

Up to seven Ancillary Boards can be connected to the same serial bus as the status indicators providing distributed control and signalling at multiple locations if required. Each output of the Ancillary Board has an LED which indicates operation.

The FireBeta XT Ancillary Board contains volt-free changeover contacts for signalling the following:

• Zone 1 fire• Zone 2 fire• Zone 3 fire• Manual only mode• Disablement active• Released• Activated• Manual release operated• Extract fan operated• Hold activated

Dimensions: 155W x 136H

23911-K070 FiteBeta XT Ancillary board

ZOOM PRINT EXITPAGE 33/120 www.kfp.co.uk HOME CONTENTS

Page 34: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

INTELLIGENT ADDRESSABLE FIRE ALARM PANELS

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 34 35

ABORT SWITCH

The Abort switch is a latching push button that can be connected to the monitored hold circuit of the FireBeta XT, XT+ or ECU. When operated the switch will remain in the on position until physically released. The Abort button allows the operator to prevent the release of extinguishing gas in the event of accidental activation of the system. The system can be reset before the Abort button is physically released.

• Dimensions: 108W x 108H x 85D• 35mm red, mushroom type push button, configured as a latching switch with two sets of single pole single throw contacts rated 5A @ 30 V dc• The screw type terminals can accept conductors up to 4mm• The contacts house a 100 ohm alarm resistor which is introduced into the circuit when the switch is operated

53836-K180 Abort Switch53836-K179 Hold Switch

HOLD SWITCH

The Hold Switch is a non-latching push button that can be connected to the monitored Hold circuit on the extinguishing control panel. When the extinguishing system is in alarm and gas release is imminent the Hold switch can be pressed to stop the extinguishing release sequence. The release sequence will be delayed as long as the Hold switch remains pressed allowing all personnel to evacuate before extinguishing gas is released into the area. When the Hold switch is released the extinguishing sequence re-starts and the extinguishing gas will be released into the risk area.

• Dimensions: 108W x 108H x 85D• 35mm red, mushroom type push button, configured as a non latching switch with two sets of single pole single throw contacts rated 5A @ 30V dc• The screw type terminals can accept conductors up to 4mm• The contacts house a 100 ohm alarm resistor which is introduced into the circuit when the switch is operated

2

2

ZOOM PRINT EXITPAGE 34/120 www.kfp.co.uk HOME CONTENTS

Page 35: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 34 35ZOOM PRINT EXITPAGE 35/120 www.kfp.co.uk HOME CONTENTS

Page 36: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 36

DETECTION AND ALARM

ZOOM PRINT EXITPAGE 36/120 www.kfp.co.uk HOME CONTENTS

Page 37: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

The Kidde Discovery and XP95 ranges offer a wide selection of intelligent detectors, manual call points, interface modules and audio/visual devices compatible with the Vega Analogue Addressable control panel.

Conventional devices are connected to a control panel as a zone in the case of detection devices, or as a circuit in the case of audio/visual devices. Conventional systems do not have the capability of identifying individual

devices but only identify the zone or a circuit as a whole therefore in an alarm condition the search area for a conventional detection zone can be large (up to 2000m2).

The Kidde Orbis and Series 65 range of detectors are compatible with the Sirius II conventional control panel and also the FireBeta XT and XT+ range of extinguishing control panels.

37

Detection and Alarm devices can be separated into two main categories “Intelligent” and “Conventional”.

Intelligent devices have unique addresses and are connected to control panels in a loop configuration. Intelligent detectors give advanced warning of a developing hazard and can pinpoint the individual device raising alarm. Intelligent audio/visual devices can be independently programmed and controlled allowing for extensive cause and effects such as phased evacuation.

ZOOM PRINT EXITPAGE 37/120 www.kfp.co.uk HOME CONTENTS

Page 38: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Detector types

Ionisation Smoke Detectors detect smoke by using a small ionising radiation source. Ionisation detectors respond well to fast-burning (flaming) fires and are widely used for property protection.

Optical Smoke Detectors detect smoke by using an LED light source and photodiode. Optical detectors respond particularly well to slow-burning, smouldering fires and are widely used for life protection

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 38 39

DETECTION AND ALARM

Heat Detectors are available in two types: fixed temperature and rate-of-rise. Rate-of–rise detectors monitor for rapid increases in the temperature within the area, but also have a fixed temperature limit which will trigger an alarm if the rate of temperature rise has been too slow. Fixed temperature heat detectors are designed to alarm at a set temperature value. Heat detectors are more suitable in environments where conditions would lead to false alarms with smoke detectors, e.g. kitchens, boiler rooms etc. However a heat detector will respond only when a fire is well established and generating high heat output.

ZOOM PRINT EXITPAGE 38/120 www.kfp.co.uk HOME CONTENTS

Page 39: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 38 39

Multisensor Detectors are a combined optical and heat detector allowing flexibility in the detection of fires. Using the combined detection method a fire condition can be confirmed if both heat and smoke sensors operate. Multisensor detectors are general purpose detectors which respond well to a wide range of fires.

Carbon Monoxide (CO) Detectors detect poisonous carbon monoxide gas produced by combustion. The detector contains an electromechanical cell which reacts to the presence of CO in the air. The CO detector will not detect smoke or any other products of combustion. Carbon Monoxide detectors are particularly effective at detecting deep-seated smouldering fires.

Beam Detectors consist of three main parts: The transmitter, which projects a beam of infra-red light; the receiver, which registers the light and produces an electrical signal; and the interface, which processes the signal and generates an alarm or fault. When a fire develops, smoke particles obstruct the infra red beam and once a preset threshold has been exceeded, the detector will go into alarm. Beam detectors are designed to protect large open spaces such as atria, warehouses, museums, and churches.

Flame Detectors are designed to detect either ultraviolet (UV) or infra red (IR) radiation emitted by a fire. A number of different types of flame detectors from UV, IR, UV/IR, dual, triple and multispectrum detectors are available for various different applications . Flame detectors are designed to protect areas where flaming fires may be expected such as aircraft hangars, power plants, oil refineries and paper manufacturing.

ZOOM PRINT EXITPAGE 39/120 www.kfp.co.uk HOME CONTENTS

Page 40: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

DETECTION AND ALARM – INTELLIGENT FIRE DETECTION

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 40 41

Discovery Intelligent Fire Detection

Discovery is a range of high-specification, intelligent fire detectors developed to meet the requirements of sophisticated systems while providing engineers with an additional dimension in fire protection capability. Discovery has a ‘distributed intelligence system’ where decisions are made in the detector head as well as at the control panel. Drift compensation is also incorporated into the detector, allowing it to adapt to dirty or dusty environments reducing false alarms.

Key features of Discovery include:

• Rejection of transient signals

• Flashing LED option

• Five response modes for ease of optimisation to changing environments

• Drift compensation to ensure constant sensitivity

• Four bytes of non-volatile memory for user data

• Alarm flag for fast alarm reporting

• Conventional alarm facility during control panel processor fault

• 360° visibility in alarm

• Compatible with XP95 systems

• Insect resistant

Intelligent Fire Detection

There are two types of intelligent detection system those with ‘distributed intelligence’ and those with ‘centralised intelligence’.

In systems with distributed intelligence the detectors incorporate processors, which can determine whether the alarm levels of smoke or heat exist and can initiate action accordingly.

Detectors in systems with centralised intelligence monitor the air around them for smoke or heat and transmit the data to the control panel on interrogation. The processor in the panel compares the values with stored values and determines whether a pre-alarm or alarm should be signalled.

The advantages of distributed intelligence are local adaptation to environment and reduction of traffic on the supply and data wires. The advantage of centralised intelligence is the ability to upgrade a system very quickly and easily by upgrading the control panel.

ZOOM PRINT EXITPAGE 40/120 www.kfp.co.uk HOME CONTENTS

Page 41: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

23900-K143 Discovery Multisensor Detector

The Discovery Heat Detector, distinguishable by the low airflow resistant case, uses a single thermistor to sense the air temperature around the detector.

DISCOVERY HEAT DETECTOR

23900-K144 Discovery Heat Detector

The Discovery Multisensor Detector comprises optical smoke and thermistor temperature sensors whose outputs are combined to give the final analogue value. As a result, the multisensor is useful over a wide range of applications and is highly immune to false alarms.

DISCOVERY MULTISENSOR DETECTOR

• Ideal in environments that are dirty or smokey under normal conditions

• Well suited for warehouses, loading bays and car parks

• Unaffected by wind or atmospheric pressure

• Remote test feature

• Ideal for a wide range of applications• Highly immune to false alarms• Well suited for environments such as hotel bedrooms • Unaffected by wind or atmospheric pressure • Well suited for sensitive environments• Heat only, optical only modes • Remote test feature

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 40 41

The Discovery Ionisation Smoke Detector uses a low activity radioactive foil to irradiate the air in the smoke chamber causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm.

DISCOVERY IONISATION SMOKE DETECTOR

23900-K141 Discovery Ionisation Smoke Detector

23900-K142 Discovery Optical Smoke Detector

The Discovery Optical Smoke Detector works using the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely.

DISCOVERY OPTICAL SMOKE DETECTOR

• Responds well to fast-burning, flaming fires • Designed to operate in a variety of environments • Remote test feature

• Responds well to slow-burning, smouldering fires • Well suited for bedrooms and escape routes• Unaffected by wind or atmospheric pressure• Remote test feature

ZOOM PRINT EXITPAGE 41/120 www.kfp.co.uk HOME CONTENTS

Page 42: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

DETECTION AND ALARM – INTELLIGENT FIRE DETECTION

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 42 43

The Discovery Carbon Monoxide (CO) Detector is good at detecting deep-seated fires.Please note that CO detectors do not detect smoke particles or heat and are not universal replacements for smoke detectors.

DISCOVERY CARBON MONOXIDE DETECTOR

23900-K147 Discovery Carbon Monoxide Detector

23900-H05 Discovery/XP95 mounting base c/w Xpert card

All detectors in the Discovery range fit the Intelligent Mounting Base. The Mounting Base is a low insertion force base with stainless steel contacts for the detector terminals.XPERT cards are supplied with all bases.

DISCOVERY/XP95 MOUNTING BASE C/W XPERT CARD

• Enhanced detection capability

• Early response to hot fires

• Ideal for smouldering fires

• Less susceptible to false alarms caused by steam than smoke alarms

• Five response modes

• XPERT addressing

• One way fit • Locking feature to prevent unauthorised removal

23900-K203 Discovery/XP95 Isolating base

The Intelligent Deep Base is a mounting base for Discovery products which has an increased depth allowing for cables to be inserted into the side of the product.

DISCOVERY/XP95 DEEP MOUNTING BASE

23900-K204 Discovery/XP95 Deep mounting base

The new Isolating Base senses and detects short circuit faults on Discovery/XP95 loops and spurs.

DISCOVERY/XP95 ISOLATING BASE

• Enables surface wiring

• XPERT Addressing

• One way fit

• Locking feature to prevent unauthorised removal

• Up to 20 devices may be installed between isolating bases

ZOOM PRINT EXITPAGE 42/120 www.kfp.co.uk HOME CONTENTS

Page 43: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 42 43

The Discovery Manual Call Point is compliant with EN54-11. The Call Point can be addressed at the commissioning stage by means of a seven-segment DIL switch. When operated, the manual call point interrupts the polling cycle for a fast response.

DISCOVERY MANUAL CALL POINT

23900-K195 Discovery Manual Call Point (surface)

• Flashing LED option

• Plug and play terminal connections for fast wiring

• Allows wiring continuity testing before fitting

• Isolated version available

• Reports an alarm in under 0.2 seconds

• Resettable element

23900-K196 Discovery Manual Call Point with Isolator (surface)

The Waterproof Manual Call Point has been designed for use outdoors and in places where moisture can occur. It is compliant with EN54-11 and can be used with the Discovery range.

DISCOVERY WEATHERPROOF MANUAL CALL POINT

23900-K197 Discovery Weatherproof Manual Call Point

• Plug and play terminal connections for fast wiring

• Allows wiring continuity testing before fitting

• Resettable element

• IP 67

The MiniDisc Remote Indicator is a light-weight, compact indicator for use in fire Protection systems. The remote indicator can be wired to detectors which are not visible, i.e. in ceiling/floor voids. This allows identification of the operated device.

MINIDISC REMOTE INDICATOR

23900-K095 MiniDisc Remote Indicator

• Can be used across the entire Apollo range• Small and discrete• Anti-tamper screw to protect against unauthorized removal.

A universal address card supplied with all Discovery/XP95 bases. Using a coding guide pips are removed to set the address of the inserted detector.

BLANK XPERT CARD

23900-H09 Blank XPERT card

• Simplifies and speeds up installation and commissioning

• Uses patented, proven technology

• Address remains the same, no matter how often detectors are replaced

• Flexibility to create any address

ZOOM PRINT EXITPAGE 43/120 www.kfp.co.uk HOME CONTENTS

Page 44: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

DETECTION AND ALARM – INTELLIGENT FIRE DETECTION

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 44 45

XP95 Intelligent Fire DetectionThe XP95 range of intelligent fire detectors is advanced in design, improved in performance and has unique features that benefit the installer and end user.

The range features smoke detectors (ionisation and optical), standard and high temperature heat detectors and a multisensor. Beam detectors, flame detectors, manual call points, audio visual signalling devices, interface units and isolators complete the range. XP95 is a ‘central intelligence’ system where all the decisions are made by the control panel.

Key features of XP95 include:

• Alarm Flag for fast alarm reporting

• Alarm Address for fast location of alarm

• XPERT card addressing

• Electronics-free base

• Easy installation

• Elegant design

• Insect resistant

The XP95 Ionisation Smoke Detector uses a low activity radioactive foil to irradiate the air in the smoke chamber causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm.

XP95 IONISATION SMOKE DETECTOR

23900-K040 XP95 Ionisation Smoke Detector

23900-K041 XP95 Optical Smoke Detector

The XP95 Optical Smoke Detector works using the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely.

XP95 OPTICAL SMOKE DETECTOR

• Responds well to fast-burning, flaming fires

• Designed to operate in a variety of environments

• Minimal effects from temperature, humidity, atmospheric pressure

• Well protected against electromagnetic interference over a wide frequency range

• Responds well to slow-burning, smouldering fires

• Well suited for bedrooms and escape routes

• Unaffected by wind or atmospheric pressure

ZOOM PRINT EXITPAGE 44/120 www.kfp.co.uk HOME CONTENTS

Page 45: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 44 45

The XP95 Heat Detector monitors temperature by using a single thermistor network which provides a count output proportional to the external air temperature. The XP95 range features two Heat Detectors, standard and high temperature. The standard heat detector is classified as an A2S device and will report an alarm at 55°C. The high temperature detector, classified as a CS device, will report an alarm at 90°C.

XP95 HEAT DETECTOR

23900-K042 XP95 Heat Detector Standard

• Ideal in environments that are dirty or smoky under normal conditions

• Well suited for warehouses, loading bays and car parks

• Unaffected by wind or atmospheric pressure

23900-K050 XP95 Heat Detector High Temperature

23900-K130 XP95 Multisensor Detector

The XP95 Multisensor Detector contains an optical smoke sensor and a thermistor temperature sensor whose outputs are combined to give the final analogue value.

XP95 MULTISENSOR DETECTOR

• Sensitive to a wide range of fires

• Well suited for environments such as hotel bedrooms

• Unaffected by wind or atmospheric pressure

23900-K161 XP95 Isolator

The XP95 Isolator is placed at intervals on the loop and ensures that, in the case of a short circuit, only the section between the isolators will be affected. When the short circuit is removed, the isolators automatically restore power and data to the isolated section.

XP95 ISOLATOR

• Detects wiring short circuits using patented technology

• Minimises disruption from short circuits

• Automatic de-isolation on short circuit removal

• Up to 20 devices may be installed between isolators

The XP95 Isolating base is unique and designed only to accept the XP95 Isolator.

XP95 ISOLATOR BASE

23900-H09 XP95 Isolator base

ZOOM PRINT EXITPAGE 45/120 www.kfp.co.uk HOME CONTENTS

Page 46: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

DETECTION AND ALARM – INTELLIGENT FIRE DETECTION

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 46 47

23900-H05 Discovery/XP95 Mounting base

All detectors in the XP95 range fit the Intelligent Mounting Base. The Mounting Base is a low insertion force base with stainless steel contacts for the detector terminals.XPERT cards are supplied with all bases.

DISCOVERY/XP95 MOUNTING BASE C/W XPERT CARD

• XPERT addressing

• One way fit • Locking feature to prevent unauthorised removal

The Intelligent Deep Base is a mounting base for Discovery products which has an increased depth allowing for cables to be inserted into the side of the product.

DISCOVERY/XP95 DEEP MOUNTING BASE

23900-K204 Discovery/XP95 Deep mounting base

• Enables surface wiring The Low Power Relay Base incorporates a low power relay to control field equipment such as automatic door closers.

INTELLIGENT LOW POWER RELAY BASE

23900-K196 Intelligent Low Power Relay Base

• Gives a set of voltage free contacts controlled by the remote output of a detector

• Draws negligible current

• Capable of switching up to 30V at 1A

23900-K203 Discovery/XP95 Isolating base

The Isolating Base senses and detects short circuit faults on Discovery/XP95 loops and spurs.

DISCOVERY/XP95 ISOLATING BASE

• Up to 20 devices may be installed between isolating bases

ZOOM PRINT EXITPAGE 46/120 www.kfp.co.uk HOME CONTENTS

Page 47: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 46 47

The XP95 Base Adaptor is designed to allow XP95 detectors to be fitted to an existing Series 90 base. The adaptor eliminates the need to re-wire an existing Apollo intelligent system.

SERIES 90 TO XP95 BASE ADAPTOR

23900-K226 Series 90 to XP95 Base Adaptor

• Allows an existing range to be updated with ease

• Eliminates the need for re-wiring

A universal address card supplied with all Discovery/XP95 bases. Using a coding guide pips are removed to set the address of the inserted detector.

BLANK XPERT CARD

23900-H09 Blank XPERT card

• Simplifies and speeds up installation and commissioning

• Uses patented, proven technology

• Address remains the same, no matter how often detectors are replaced

• Flexibility to create any address

The XP95 Manual Call Point is compliant with EN54-11. The address of each call point is set at the commissioning stage by means of a seven-segment DIL switch. The device features plug and play terminal connections and a resettable element.

XP95 MANUAL CALL POINT

• Plug and play terminal connections for fast wiring

• Allows wiring continuity testing before fitting

• Reports an alarm in under 0.2 seconds

• Resettable element

23900-K192 Manual Call Point with Isolator (surface)

The intelligent Dual Infra-Red (IR2) Flame Detector is designed for use in areas where flaming fires may be expected. The detector has two sensors which respond to different IR wavelengths to discriminate between flames and spurious sources of radiation. Applications include aircraft hangars, coal handling, paper manufacturing plants and woodworking environments.

DUAL IR FLAME DETECTOR

• Sensitive to flickering IR radiation

• Detects through films of oil, dust, water and ice

• Responds to flickering flames, including those invisible to the naked eye

• Compatible with XP95 and Discovery protocols

• Remote optical self test function

• 90o field of view

• Up to 40m coverage

23900-K092 XP95 Dual IR Fire detector

23900-K091 Flame detector mounting bracket

23900-K090 Flame detector weathershield

ZOOM PRINT EXITPAGE 47/120 www.kfp.co.uk HOME CONTENTS

Page 48: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

DETECTION AND ALARM – INTELLIGENT AUDIO VISUAL SIGNALLING

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 48 49

The Optical Beam Detector is made up of three main parts: the transmitter, which projects a beam of infra-red light, the receiver, which registers the light and produces an electrical signal, and the interface, which processes the signal and generates an alarm or fault.

OPTICAL BEAM DETECTOR

• Loop powered

• Compatible with Discovery and XP95 protocols

• Four selectable sensitivity levels

• Drift compensation

• Remote interface

• Simple wiring and alignment

23900-K087 XP95 Optical beam detector

23900-K088 Beam detector reflector

The MiniDisc Remote Indicator is a light-weight, compact indicator for use in fire Protection systems. The remote indicator can be wired to detectors which are not visible, i.e. in ceiling/floor voids. This allows identification of the operated device.

MINIDISC REMOTE INDICATOR

23900-K095 MiniDisc Remote Indicator

• Can be used across the entire Apollo range• Small and discrete• Anti-tamper screw to protect against unauthorized removal.

ZOOM PRINT EXITPAGE 48/120 www.kfp.co.uk HOME CONTENTS

Page 49: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 48 49

Intelligent Audio/VisualSignalling

Kidde offers a wide range of Intelligent audio/visual signalling devices for use with Analogue addressable control panels to meet the requirements of the DDA.

The intelligent audio/visual signalling devices are compatible with both XP95 and Discovery protocols.

The Intelligent Open-Area Sounder has been designed for use in open areas and can be connected to any Discovery or XP95 system. Sound output of 100dB(A) at 90° +/- 3dB(A).

INTELLIGENT OPEN-AREA SOUNDER (SONOS)

23900-K222 Intelligent Open-Area Sounder, Red (Sonos)

23900-K221 100dB (A) Weatherproof Sounder Red

The 100dB (A) Weatherproof Sounder is designed for use in open areas and can be connected to any Discovery or XP95 system. The sounder comprises a backbox and sounder unit supplied together.

100dB (A) WEATHERPROOFLOOP POWERED SOUNDER

• Self-test fault monitoring

• Choice of tones • Synchronisation of alarm • Weatherproof IP65 • Comes with Isolating Base as standard • Loop powered

• IP 66 (immune to the affects of wind and precipitation)

• Output is 100dB (A) at 90°

• Current consumption of 5.0mA

• Can be synchronised

• Loop powered

• Wall mounted

ZOOM PRINT EXITPAGE 49/120 www.kfp.co.uk HOME CONTENTS

Page 50: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

DETECTION AND ALARM – INTELLIGENT AUDIO VISUAL SIGNALLING

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 50 51

The Beacon Base is a loop-powered beacon combined with a standard Intelligent Mounting Base. It is used to signal a fire alarm in enclosed areas. The beacon base can be used with either a detector fitted or with a cap as a stand-alone alarm device.

LOOP-POWERED BEACON BASE

23900-K218 Loop-Powered Beacon base with Standard Flash

23900-K217 Discovery Open-Area Sounder beacon Red Lens

The Discovery Open-Area Sounder Beacon makes full use of the Discovery protocol and has been designed for use indoors and outdoors. When the fire system is being commissioned a Magnetic Wand can be used to adjust and test each sounder locally.

Magnetic wand is an optional item, ordered seperately.

DISCOVERY OPEN-AREA SOUNDER BEACON

• Beacon flash rate of once per second

• Synchronisation of beacon flash

• Unique beacon self-test

• Loop powered

• Isolator option

• Loop powered

• Tones can be used for other purposes in addition to warning of fire, ideal for schools

• Soft start option, ideal for hospitals and nursing homes

The Integrated Base Sounder comprises a loop powered sounder within an intelligent mounting base and is for use with Discovery or XP95 ranges. It is designed for use in enclosed areas.

INTEGRATED LOOP POWERED SOUNDER BASE

23900-K220 Integrated Loop powered sounder base

23900-K219 Intelligent Open-Area Beacon, Red Lense Sonos

The Intelligent Open-Area Beacon has been developed for use in situations where there is a risk sounders may not be heard.

INTELLIGENT OPEN-AREA BEACON SONOS

• Two tone ranges

• Synchronisation of ‘alert’ and ‘evacuate’ tones

• Unique acoustic self-test

• Integrated base

• Self-test fault monitoring

• Weatherproof IP65

• Synchronisation of alarm

• Comes with Isolating Base as standard

• Loop powered

ZOOM PRINT EXITPAGE 50/120 www.kfp.co.uk HOME CONTENTS

Page 51: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 50 51

The sounder beacon base is a loop-powered sounder and beacon combined with a standard intelligent mounting base. It is used to signal a fire alarm in enclosed areas. The sounder beacon base can be used either with a detector fitted or with a cap for operation as a stand-alone alarm device.

XP95 SOUNDER BEACON BASE

23900-K216 XP95 Sounder Beacon Base

• Two volume ranges 55-75dB(A) and 75-91dB(A)

• Beacon flash rate of once per second

• Synchronisation of ‘alert’ and ‘evacuate’ tones

• Synchronisation of beacon flash

• Unique acoustic and beacon self test

• Enables DDA compliance

ZOOM PRINT EXITPAGE 51/120 www.kfp.co.uk HOME CONTENTS

Page 52: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

DETECTION AND ALARM – INTERFACE MODULES

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 52 53

Interface Modules

Kidde supply a range of addressable interface modules which are compatible with the Kidde Vega intelligent control panel. The interfaces provide various types of input, output and combined input and output units, which allow other equipment to be monitored and controlled by the Intelligent Fire System through the detection loop.

Interface module range includes:

• Standard interfaces with isolators• Mini interfaces• DIN-Rail interface

Standard Interfaces with Isolators

Standard Interfaces with Isolators are fitted with bi-directional short-circuitisolators so that they are unaffected by a single short circuit on either loop input or output. However, the Input/Output Unit and Output Unit with isolator are exceptions to this. The removal of loop power to these interfaces will cause a‘set’ relay to ‘reset’.

Key features of Interfaces:

• Easy to install

• Well protected

• Modular design

• A neat solution

ZOOM PRINT EXITPAGE 52/120 www.kfp.co.uk HOME CONTENTS

Page 53: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 52 53

The Input/Output unit with isolator provides a voltage free single pole, change-over relay output, a single monitored switch input and an unmonitored non-polarised opto-coupled input.

Dimensions 150W x 90H x 48D

INPUT/OUTPUT UNIT WITH ISOLATOR

23900-K132 Input/Output Unit with Isolator

23900-K133 Output Unit with Isolator

The Output Unit with Isolator provides two voltage free single pole, change-over relay outputs. It is a simplified version of the Input/Output unit without circuitry for monitoring inputs.

Dimensions 150W x 90H x 48D

OUTPUT UNIT WITH ISOLATOR

• It can report fault, switch open and switch closed levels

• Four status LEDs

• Loop powered

• Voltage free

• Capable of switching up to 30V at 1A

• Two status LEDs

• Capable of switching up to 30V at 1A

The XP95 Sounder Control Unit with isolator is used to control the operation of a Zone of conventional sounders and report their status to the control panel.

Dimensions 150W x 90H x 48D

SOUNDER CONTROL UNIT WITH ISOLATOR

23900-K137 Sounder Control Unit with Isolator

23900-K134 Switch Monitor with Isolator

The Switch Monitor with Isolator is designed to monitor the state of one or more single pole, volt free contacts connected on a single pair of cables reporting the status to Apollo compatible analogue control equipment.

Dimensions 150W x 90H x 48D

SWITCH MONITOR WITH ISOLATOR

• Requires external PSU 9–32vdc

• Allows sounders to be operated continuously or pulsed, 1 second on 1 second off

• May be synchronized when in pulsed operation

• Three status LEDs

• Output rated 1A @ 30vdc

• Four input states - ’normal’, ’fault’, ’pre-alarm’ and ’alarm’

• Three status LEDs

• Loop powered

ZOOM PRINT EXITPAGE 53/120 www.kfp.co.uk HOME CONTENTS

Page 54: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

DETECTION AND ALARM – INTERFACE MODULES

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 54 55

SWITCH MONITOR PLUS WITH ISOLATOR

D23900-K135 Switch Monitor Plus with Isolator

23900-K136 Zone Monitor with Isolator

The Zone Monitor with Isolator powers and controls the operation of a zone of up to 20 Apollo Series 65 or Orbis fire detectors from a Discovery or XP95 Loop.

Dimensions 150W x 90H x 48D

ZONE MONITOR WITH ISOLATOR

• Selectable alarm delay for monitoring flow switches

• Output for resetting a remote detector

• Four input states - ’normal’, ’fault’, ’pre-alarm’ and ’alarm’

• Three status LEDs

• Loop powered

• Two status LEDs• Loop powered

Mini Interfaces use very compact enclosures for installation into other equipment.

Mini Interfaces

23900-K205 Mini Switch Monitor

The Mini Switch Monitor is designed to monitor the state of one or more single pole, volt free contacts connected on a single pair of cables reporting the status to Apollo compatible control analogue equipment.

Designed to be fitted on a standard 35mm DIN-Rail or mounted within an enclosure, its compact size allows it to be installed where space is limited.

Dimensions 39W x 39H x 20D

MINI SWITCH MONITOR

• Loop powered

• Isolated as standard

• Interrupt/non interrupt in one unit

• ‘Pre-alarm’ status available

• Three, coloured LEDs, giving clear status indication

The Switch Monitor Plus with Isolator is designed to monitor the state of one or more single pole, volt free contacts connected on a single pair of cables reporting the status to Apollo compatible analogue control equipment.

Dimensions 150W x 90H x 48D

ZOOM PRINT EXITPAGE 54/120 www.kfp.co.uk HOME CONTENTS

Page 55: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 54 55

DIN-RAIL INPUT/OUTPUT UNIT

23900-K069 DIN-Rail Input/Output Unit

23900-K070 DIN-Rail output unit

The DIN-Rail Output Unit provides a voltage-free single pole, change-over relay output. It is a simplified version of the Input/Output unit without circuitry for monitoring inputs.

Dimensions 110W x 107H x 20D

DIN-RAIL OUTPUT UNIT

• It can report fault, switch open and switch closed levels

• Three status LEDs

• Loop powered

• Capable of switching up to 30V at 1A

• Single status LED

• Loop powered

• Capable of switching up to 30V at 1A

DIN-RailInterfaces

DIN-Rail Interfaces feature enclosures that clip to standard 35mmDIN-Rails or are screwed to the base of a larger enclosure. Theyenable fire system designers to determine the functions requiredand create multi-purpose interfaces for individual sites.

The DIN-Rail Input/Output Unit provides a voltage free single pole, change-over relay output, a single monitored switch input and an unmonitored non-polarised opto-coupled input.

Dimensions 110W x 107H x 20D

ZOOM PRINT EXITPAGE 55/120 www.kfp.co.uk HOME CONTENTS

Page 56: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

DETECTION AND ALARM – INTERFACE MODULES

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 56 57

The DIN-Rail Switch Monitor Plus is designed to monitor the state of one or more single pole, volt free contacts connected on a single pair of cables reporting the status to Apollo compatible analogue equipment.

Dimensions 110W x 107H x 20D

DIN-RAIL SWITCH MONITOR PLUS

23900-K072 DIN-Rail Switch Monitor Plus

23900-K073 DIN-Rail Zone Monitor with Isolator

The Zone Monitor powers and controls the operation of a zone of up to 20 Apollo Series 65 or Orbis fire detectors from a Discovery or XP95 Loop.

Dimensions 110W x 107H x 20D

DIN-RAIL ZONE MONITOR WITH ISOLATOR

• Output for resetting a remote detector

• Four input states – ‘normal’, ‘fault’, ‘pre-alarm’ and ‘alarm’

• Selectable alarm delay for monitoring flow switches

• Two status LEDs

• Loop powered

• Built in short cicuit isolator

• Two status LEDs

• Loop powered

DIN-RAIL SOUNDER CONTROL UNIT

23900-K074 DIN-Rail sounder control unit

23900-K071 DIN-Rail switch monitor

The DIN-Rail Switch Monitor is designed to monitor the state of one or more single pole, volt free contacts connected on a single pair of cables and to report the status to Apollo compatible analogue control equipment.

Dimensions 110W x 107H x 20D

DIN-RAIL SWITCH MONITOR

• Requires external PSU 9 – 50 vdc

• Allows sounders to be operated continuously or pulsed, 1 second on, 1 second off

• May be synchronized when in pulsed operation

• Two status LEDs

• Four input states – ‘normal’, ‘fault’, ‘pre-alarm’ and ‘alarm’

• Two status LEDs

• Loop powered

The DIN-Rail Sounder Control Unit is used to control the operation of a zone of Conventional sounders and report their status to the control panel.

Dimensions 110W x 107H x 20D

ZOOM PRINT EXITPAGE 56/120 www.kfp.co.uk HOME CONTENTS

Page 57: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 56 57

The DIN-Rail Dual Isolator provides two independent Isolators which sense and isolate short circuits on Discovery or XP95 loops and spurs.

DIN-RAIL DUAL ISOLATOR

23900-K075 DIN-Rail Dual Isolator

• Polarity sensitive

• Up to 20 detectors can be installed between isolators

• Two status LEDs

• Loop powered

ZOOM PRINT EXITPAGE 57/120 www.kfp.co.uk HOME CONTENTS

Page 58: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

DETECTION AND ALARM – CONVENTIONAL FIRE DETECTION

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 58 59

Conventional Fire Detection

In conventional systems the detectors are wired as a circuit or zone. They signal fire conditions to the control panel by changing from a high to low impedance. The panel detects this impedance change by current monitoring and identifies the zone where the alarm has been raised.

Compatible with the Kidde Sirius II and FireBeta XT and XT+ range of extinguishing control panels they are an ideal cost effective detection system for small area applications.

ORBIS Conventional Fire Detection

Orbis is a range of conventional detectors which has been developed with sophisticated technology previously only found in intelligent detectors. Orbis is a range with modern styling and incorporates a mounting base wihich saves installation time.

Key features of Orbis:

• Automatic drift compensation with DirtAlert® warning

• Patented FasTest® which reduces the time taken to test detectors

• SensAlert® uses a flashing LED to indicate that the sensor is not operating correctly

• StartUp™ for fast commissioning

• Attractive and compact design

• Electrically compatible with Series 60 and Series 65

• Wide voltage and operating temperature ranges

• Algorithms for transient rejection

• 360° visibility of LEDs

• Insect Resistant

ZOOM PRINT EXITPAGE 58/120 www.kfp.co.uk HOME CONTENTS

Page 59: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 58 59

The Orbis Optical Smoke Detector works using the well established light scatter principle, however, the sensing technology is radically different in design from previous optical detectors and significantly reduces false alarms.

ORBIS OPTICAL SMOKE DETECTOR

23900-K178 ORBIS Optical Smoke Detector

23900-K179 ORBIS Multisensor Detector

The Orbis Multisensor detector benefits from the same false alarm reduction technology as the optical detector. It is a thermally enhanced smoke detector and so will not give an alarm from heat alone.

ORBIS MULTISENSOR DETECTOR

• Responds well to slow-burning, smouldering fires

• Performs well in black and white smoke

• Extra confirmation of smoke before alarm signal is given

• Reduced incidence of false alarms

• Sensing chamber keeps out dust and other airborne contaminants

• Operates over a broad range of voltages at extremes of temperature

• Responds well to fast-burning, flaming fires

• Reduced incidence of false alarms

• Increased reliability of detection

• Sensing chamber keeps out dust and other airborne contaminants

• Operates over a broad range of voltages at extremes of temperature

ORBIS HEAT DETECTOR

The Orbis Heat Detector monitors temperature by using a single thermistor network which provides a voltage output proportional to the external air temperature. There are seven classes of heat detectors in the Orbis range designed to suit a wide variety of operating conditions.

ORBIS HEAT DETECTOR

• Can be used for applications where smoke detectors are unsuitable

• Ideal in environments that are dirty or smoky under normal conditions

• Reduced incidence of false alarms

• Increased reliability of detection

23900-K180 Rate-of-Rise MAT 50 C A1R - Standard

23900-K181 Static MAT 50 C A2S - Standard

23900-K182 Rate-of-Rise MAT 65 C BR - Standard

23900-K183 Static MAT 65 C BS - Standard

23900-K184 Rate-of-Rise MAT 80 C CR - Standard

23900-K185 Static MAT 80 C CS - Standard

MAT (Maximum Application Temperature)

ZOOM PRINT EXITPAGE 59/120 www.kfp.co.uk HOME CONTENTS

Page 60: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

DETECTION AND ALARM – CONVENTIONAL FIRE DETECTION

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 60 61

The TimeSaver Base® is a completely new design that provides installers with an open working area with fixing holes shaped to allow a simple mounting procedure.

TIMESAVER BASE

23900-K186 TimeSaver Base

23900-K187 TimeSaver Diode Base

The TimeSaver Diode Base has the same design as the standard TimeSaver Base® with the addition of a diode. It is used in systems which house active EOL monitoring for head removal.

TIMESAVER DIODE BASE

• Grouped terminals to make wiring easy

• Two fixing centres

• LED alignment mark

• Cable stripping guide

• Detector locking mechanism

• Grouped terminals to make wiring easy

• Two fixing centres

• LED alignment mark

• Cable stripping guide

• Continuity link for voltage testing of zone wiring prior to commissioning

• Detector locking mechanism

• Other devices continue to work during unauthorised removal of detectors

The TimeSaver Relay Base incorporates a single pole voltage free change-over contact for switching external equipment. When the detector changes to the alarm state, the relay is energised causing the contact to change state. The contact will remain in this condition until the detector is reset.

TIMESAVER RELAY BASE

23900-K188 TimeSaver Relay Base

• Grouped terminals to make wiring easy

• Two fixing centres

• LED alignment mark

• Cable stripping guide

• Continuity link for voltage testing of zone wiring prior to commissioning

• Detector locking mechanism

• Capable of switching up to 30V at 1A

The TimeSaver Deep Base is a mounting base for Orbis products which has an increased depth allowing for cables to be inserted into the side of the base.

TIMESAVER DEEP BASE

23900-K225 TimeSaver Relay Base

• Enables surface wiring

ZOOM PRINT EXITPAGE 60/120 www.kfp.co.uk HOME CONTENTS

Page 61: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 60 61

The Orbis Adaptor is designed to allow Orbis detectors to be fitted to an existing Series 60 or Series 65 base. The adaptor eliminates the need to rewire an existing Apollo conventional system.

SERIES 65 TO ORBIS BASE ADAPTOR

• Allows an existing range to be updated with ease

• Eliminates the need for re-wiring

23900-K224 Series 65 to Orbis Base Adaptor

The MiniDisk Remote Indicator is a light-weight, compact indicator for use in fire Protection systems. The remote indicator can be wired to detectors which are not visible, i.e. in ceiling/floor voids. This allows identification of the operated device.

MINIDISC REMOTE INDICATOR

23900-K095 MiniDisc Remote Indicator

• Can be used across the entire Apollo range• Small and discrete• Anti-tamper screw to protect against unauthorized removal.

ZOOM PRINT EXITPAGE 61/120 www.kfp.co.uk HOME CONTENTS

Page 62: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

DETECTION AND ALARM – MOUNTING ACCESSORIES

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 62 63

MountingAccessories

The Conduit Box is a versatile accessory for surface mounting Apollo bases. The box has knockouts to accept PG16 or M20 cable glands and conduit or minitrunking. Self-tapping screws are included to fit the detector base to the conduit box.

CONDUIT BOX

23900-K126 Conduit Box

Deckhead Mounting Boxes are robust units which can be used with various Apollo bases to protect against the ingress of water or other contaminants through the rear of the base.

DECKHEAD MOUNTING BOXES

• Easy to install

• Aesthetically pleasing

• Protects against water ingress

• Improved performance

• Available in polycarbonate or metal

23900-K201 Polycarbonate Deckhead Mounting Box

23900-K202 Metal Deckhead Mounting Box (has access ports threaded to fit M20 components)

A range of mounting accessories to supplement the Apollo detection range.

Accessories are compatible with all Apollo detector ranges.

ZOOM PRINT EXITPAGE 62/120 www.kfp.co.uk HOME CONTENTS

Page 63: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 62 63

The Ceiling Tile Mounting Box has been designed to make the installation of detectors and sounders quick and easy prior to the fitting of a false ceiling. Detector and sounder bases can be fitted, wired and, if necessary, tested and commissioned before the installation of the false ceiling.

CEILING TILE MOUNTING BOX

23900-K199 Detector Ceiling Tile Mounting Box

DIN-Rail Interface Enclosures are available in two sizes and can be used for housing intrinsically safe (IS) barriers or DIN-rail mounted interfaces. A multipurpose label that features a section for use with IS systems is supplied. For non-IS systems, the part referring to IS can simply be removed.

DIN-RAIL INTERFACE ENCLOSURES

• No need for separate backbox

• Can be used with tiles up to 25mm thick

• Quick and easy installation

• Allows multiple interfaces to be housed together

23900-K200 Sounder Ceiling Tile Mounting Box

23900-K227 DIN-Rail Interface Enclosure (4 units)

23900-K228 DIN-Rail Interface Enclosure (10 units)

The duct detector enclosure is designed to allow intelligent or conventional smoke detectors to provide detection of smoke within heating and ventilation (HVAC) ducts in commercial and industrial premises.

The enclosure is supplied with either Discovery/XP95 or Orbis detector bases (Detectors must be ordered separately), a sampling tube and exhaust tube. This allows the air from the duct to pass from the duct through the detector enclosure and back into the duct without contaminating the surrounding area.

DUCT DETECTOR ENCLOSURE

23900-H26 Duct Detector Enclosure including Discovery/XP95 mounting base and 360mm sample tube

• Operates in air speeds of 0.5m/s to 20m/s

• Transparent cover to view detector LED

• Integral smoke test port

• Optional sampling tube lengths

TBA Duct Detector Enclosure including Orbis mounting base and 360mm sample tube

23900-K168 Duct sample tube 762mm

23900-K169 Duct sample tube 1524mm

23900-K170 Duct sample tube 3048mm

ZOOM PRINT EXITPAGE 63/120 www.kfp.co.uk HOME CONTENTS

Page 64: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

DETECTION AND ALARM – TEST EQUIPMENT

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 64 65

The flame detector mounting bracket is an optional accessory for the XP95 Dual IR flame detector, part no. 23900-K092. The bracket is manufactured from stainless steel and is adjustable in two axis.

FLAME DETECTOR MOUNTING BRACKET

23900-K091 Flame Detector mounting bracket

• Allows flame detector to be moved to desired position

TestEquipmentTo keep a fire detection system in good working order, it should be subject to a routine maintenance program in accordance with locally applicable regulations. Over the course of a year every detector in the system should be functionally tested at least once, using recommended equipment. The Kidde range of test equipment enables the testing of both intelligent and conventional fire detection systems.

ZOOM PRINT EXITPAGE 64/120 www.kfp.co.uk HOME CONTENTS

Page 65: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 64 65

A self contained portable test unit capable of providing a number of useful functions in relation to individual detectors, ancillary devices or complete circuits of analogue addressable devices in the XP95 range. The test set helps the engineer guarantee correct loop configuration before an active panel is installed.

XP95 TEST SET

• User friendly LCD

• Speedy commissioning

• Reduces unnecessary site visits

NSANC50 XP95 test set, excluding printer and carry case

Designed to give a thorough on-site check of series 60/65 conventional fire detectors. Each test set is supplied with a link head, mains adaptor and carrying case with shoulder strap.

SERIES 60/65 TEST SET

23900-K010 Series 60/65 test set

• Easy to use

• 2 button select/accept options

• LCD for clear display

The detector extraction/insertion tool allows removal or installation of detectors by using two rotating heads to grip and hold the detector. The detector can be safely removed or installed from floor level, removing the need for working at height. The product should be used with the telescopic or single extension poles.

DETECTOR EXTRACTION/INSERTION TOOL

• Universal design - suits most detectors

• Suitable for use on angled ceilings

• Lightweight

23900-K012 Detector extraction/insertion tool

The smoke detector test tool allows functional testing of smoke detectors. The tool consists of a large cup which is placed over the detector to be tested creating a chamber around the device, test smoke can then be sprayed into the chamber activating the detector.

SMOKE DETECTOR TEST TOOL

23900-K049 Smoke detector test tool (test gas not included)

• Test smoke not directed at detector preventing smoke saturation

• Clear cup allows visibility of detector LED

• Suitable for use on angled ceilings

ZOOM PRINT EXITPAGE 65/120 www.kfp.co.uk HOME CONTENTS

Page 66: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

DETECTION AND ALARM – TEST EQUIPMENT

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 66 67

The heat detector test tool allows functional testing of heat detectors. The tool consists of a large cup which is placed over the detector to be tested creating a chamber around the device, the air in the chamber is then heated to the temperature required to activate the detector.

HEAT DETECTOR TEST TOOL

23900-K016 Heat detector test tool 240V

• Suitable for fixed temperature and rate of rise detectors

• Sets detectors into alarm within seconds

• Safe for use at low levels or height

• Suitable for use on angled ceilings

A 1.13m long pole for use with the detector extraction/insertion, smoke detector test and heat detector test tools.

SINGLE EXTENSION POLE

23900-K015 Carrying bag

• Toughened fibreglass

• Lightweight

• Allows access to detectors fitted up to

2.5m high

23900-K013 Telescopic extension pole

A telescopic extension pole for use with the detector extraction/insertion, smoke detector test and heat detector test tools. The pole extends from 1.26m to 4.5m enabling access to detectors fitted up to 6m high.

TELESCOPIC POLE

23900-K014 Telescopic extension pole

• Toughened fibreglass

• Lightweight

• Allows access to detectors fitted up to 6m high

23900-K015 Carrying bag

ZOOM PRINT EXITPAGE 66/120 www.kfp.co.uk HOME CONTENTS

Page 67: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 66 67

A general purpose sounder certified to EN54. The sounder provides audibility up to 106 dB(A) at 1 metre with a choice of 32 switch selectable tones including all the major international standards. The sounder is constructed from flame retardant polycarbonate, with a deep base providing weatherproof protection to IP65.

GENERAL PURPOSE SONOS ELECTRONIC SOUNDER

• Simple ‘First Fix’ installation

• Synchronised alarm tones

• Volume control 20dB

• Quick connect and disconnect

• Weatherproof – IP65

• Operating temperature -25oC to +70oC

23906-H02 Sonos electronic sounder

A general purpose low current LED beacon with a full faced, translucent case that provides a larger lens area and greater spread of light.The beacon is constructed from flame retardant polycarbonate, with a deep base providing weatherproof protection to IP65.

GENERAL PURPOSE SONOS LED BEACON

23906-K004 Sonos LED beacon – Amber

• Simple ‘First Fix’ installation

• Available with Red or Amber lens

• High efficiency LED beacon consumes less than 5mA

• Quick connect and disconnect

• Weatherproof – IP65

• Operating temperature -25oC to +70oC

ConventionalAudio/Visual SignallingKidde offers a wide range of Audio/Visual signalling devices that can be connected to conventional sounder circuits on their Vega, Sirius II, FireBeta XT and FireBeta XT+ control panels.

The Audio/Visual devices are separated into the following sections:

• General purpose• Bells• Industrial• Voice sounders

23906-K005 Sonos LED beacon – Red

ZOOM PRINT EXITPAGE 67/120 www.kfp.co.uk HOME CONTENTS

Page 68: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

DETECTION AND ALARM – CONVENTIONAL AUDIO/VISUAL SIGNALLING

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 68 69

A general purpose sounder beacon certified to ENS4 part 3. The sounder beacon provides audibility up to 106 dB(A) at 1 metre with a choice of 32 switch selectable tones including all the major international standards. The sounder uses a low current LED beacon with a full faced, translucent case that provides a larger lens area and greater spread of light. The sounder beacon is constructed from flame retardant polycarbonate, with a deep base providing weatherproof protection to IP65.

SONOS ELECTRONIC SOUNDER BEACON – RED

23905-K009 Sonos electronic sounder beacon – Red

• Simple ‘First Fix’ installation

• Sounder and Beacon can be controlled independently

• High efficiency LED beacon consumes less than 5mA

• Volume control 20dB

• Quick connect and disconnect

• Weatherproof – IP65

• Operating temperature -25oC to +70oC

The motorised bell is designed for fire alarm applications and is approved to ENS4 part 3. Designed for ease of installation, it features a robust steel gong available in two sizes 6” or 8”. The motorised bell is available in weatherproof version.

MOTORISED BELL

23905-H03 Motorised bell 8”

• Low current consumption – 20mA

• Universally recognisable sound

• Diode polarised

• 6” or 8” gong

• Operating temperature -10oC to +55oC

23905-H02 Motorised bell 6”

A high output, low current consumption ENS4 part 3 approved sounder suitable for industrial applications it provides audibility up to 110dB(A) at 1 metre. 64 switch selectable tones are available including all the major international standards The IP66 construction makes it suitable for almost any location.

NEXUS INDUSTRIAL SOUNDER

23906-K006 Nexus Industrial Sounder, 110dB(A)

• ‘First fix’ wire to base technology

• Volume control 20dB

• Three Alarm stages

• Operating temperature -25oC to +70oC

23905-K020 Weatherproof motorised bell 8”

23905-K019 Weatherproof motorised bell 6”

A combined sounder beacon device which utilises the high output, low current consumption sounder with a high efficiency red LED beacon suitable for industrial applications. The sounder provides audibility up to 110dB(A) at 1 metre with a choice of 64 switch selectable tones including all the major international standards. The IP66 construction makes it suitable for almost any location.

Approved to ENS4 part 3.

NEXUS INDUSTRIAL SOUNDER BEACON

23906-K023 Nexus Industrial Sounder, Beacon, Red lens

• First fix’ wire to base technology

• Volume control 20dB

• Three Alarm stages

• Low in-rush current

• Static/flashing beacon mode

• Operating temperature -25oC to +70oC

ZOOM PRINT EXITPAGE 68/120 www.kfp.co.uk HOME CONTENTS

Page 69: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 68 69

Combines normal sounder signals with a clear, synchronised voice message to help reduce confusion and distress during an alarm. Provided with 3 pre-programmed messages as standard it can also transmit a further 4 messages when used with an interface control unit. The sounder is constructed from flame retardant polycarbonate, with a deep base providing weatherproof protection to IP65.

SONOS VOICE SOUNDER

• Automatic synchronisation

• 106dB(A) tone and 80dB(A) message output

• Easy retrofit to existing installations

23906-K009 Sonos voice sounder

The voice sounder beacon provides all the features of the voice sounder combined with a red high efficiency LED beacon. Provided with 3 pre-programmed messages as standard it can also transmit a further 4 messages when used with an interface control unit. The sounder is constructed from flame retardant polycarbonate, with a deep base providing weatherproof protection to IP65.

SONOS VOICE SOUNDER BEACON

23906-K009 Sonos voice sounder beacon, red lens

• Automatic synchronisation

• 106dB(A) tone and 80dB(A) message output

• Full faced, translucent case gives larger lens area for greater spread of light

• Easy retrofit to existing installations

Designed to be used in conjunction with Sonos voice sounders the fire alarm interface control unit monitors the status of the sounder circuits on the fire alarm control panel, and relays the appropriate signal to the voice sounders. The interface control unit is constructed from flame retardant polycarbonate, with protection to IP65.

FIRE ALARM INTERFACE CONTROL UNIT

• Alert, evacuate, test and all clear messages for each stage of alarm

• No additional wiring

• Fully synchronised voice messages

• System status indicators

• Simple operation

53836-K265 Fire Alarm Interface control unit

Designed to be used in conjunction with Sonos voice sounders and the Nexus voice sounder beacon (gas extinguishing). The gas extinguishing interface control unit monitors the status of 1st and 2nd stage sounder circuits on the extinguishing control panel, and relays the appropriate signal to the voice sounders. The interface control unit is constructed from flame retardant polycarbonate, with protection to IP65.

GAS EXTINGUISHING INTERFACE CONTROL UNIT

53836-K264 Gas extinguishing interface control unit

• Alert, gas release imminent, gas released and gas hold messages for each stage of alarm

• No additional wiring

• Fully synchronised voice messages

• System status indicators

• Simple operation

ZOOM PRINT EXITPAGE 69/120 www.kfp.co.uk HOME CONTENTS

Page 70: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

DETECTION AND ALARM – CONVENTIONAL AUDIO/VISUAL SIGNALLING

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 70 71

Combines normal sounder signals with a clear, synchronised voice message to help reduce confusion and distress during an alarm. The sounder is provided with 4 pre-programmed fire alarm messages as standard, alternative messages can be selected from an extensive message library. A USB port is provided on the sounder allowing custom messages in WAV format to be downloaded from a PC. The sounder is constructed from flame retardant polycarbonate, with a deep base providing weatherproof protection to IP66.

NEXUS INDUSTRIAL VOICE SOUNDER

23906-K010 Nexus industrial voice sounder

• Automatic synchronisation

• Choice of up to 7 messages via three volt free contacts

• 110dB(A) tone and 90dB(A) message output

• Download messages in-house via built-in USB port

• Easy retrofit to existing installations

The Nexus Industrial voice sounder beacon provides all the features of the Nexus Industrial voice sounder combined with a red high efficiency LED beacon. Provided with 4 pre-programmed messages as standard, alternative messages can be selected from an extensive message library. The sounder is constructed from flame retardant polycarbonate, with a deep base providing weatherproof protection to IP66.

NEXUS INDUSTRIAL VOICE SOUNDER BEACON – FIRE ALARM

• Automatic synchronisation

• Choice of up to 7 messages via three volt free contacts

• 110dB(A) tone and 90dB(A) message output

• High efficiency LED beacon

• Easy retrofit to existing installations

This device is used in conjunction with the Gas extinguishing Interface Control unit, the interface control unit monitors the 1st and 2nd stage sounder outputs and on action selects the message the sounder plays. Provided with 4 pre-programmed messages as standard, alternative messages can be selected from an extensive message library. The sounder is constructed from flame retardant polycarbonate, providing weatherproof protection to IP66.

NEXUS INDUSTRIAL VOICE SOUNDER BEACON – GAS EXTINGUISHING

23906-K023 Nexus industrial sounder beacon, Gas Extinguishing

• Automatic synchronisation

• Choice of up to 7 messages via three volt free contacts

• 110dB(A) tone and 90dB(A) message output

• High efficiency LED beacon

• Easy retrofit to existing installations

23906-K011 Nexus industrial voice sounder beacon, Fire Alarm

ZOOM PRINT EXITPAGE 70/120 www.kfp.co.uk HOME CONTENTS

Page 71: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 70 71

Red colour surface mount manual call point used for manually activating the alarm condition on a fire alarm system. The call point can be fitted with either a break glass element or flexible operating element. The call point comes fitted with a 470Ω alarm resistor, compatible with the Kidde conventional control panel range.

STANDARD MANUAL CALL POINT

• Unique ‘plug & play’ installation concept

• Anti-Tamper facility

• Enhanced aesthetics

• Available with English/Arabic text

23908-H01 Manual Call Point, Red, surface mount

The Weatherproof Manual Call Point is an IP67 sealed version of the standard manual call point. The enhanced environmental protection allows the unit to be installed in many external environments where water and dirt are likely to be present.

WEATHERPROOF MANUAL CALL POINT

• Unique ‘plug & play’ installation concept

• Anti-Tamper facility

• Enhanced aesthetics

• Available with English/Arabic text

ConventionalManual call pointsKidde offers a wide range of Manual Call Points that can be connected to their, Sirius II, FireBeta XT and FireBeta XT+ control panels.

The range of call points includes:

• Standard• Weatherproof• Extinguishing release

23908-K026 Manual Call Point, Red, surface mount, English/Arabic text

23908-H02 Weatherproof Manual Call Point, Red

23908-K025 Weatherproof Manual Call Point, Red, English/Arabic text

ZOOM PRINT EXITPAGE 71/120 www.kfp.co.uk HOME CONTENTS

Page 72: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

DETECTION AND ALARM – DOOR RELEASE AND BATTERIES

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 72 73

For use with the Kidde FireBeta XT/XT+ extinguishing control panels the call point provides the facility to manual activate the extinguishing release sequence. The call point is yellow with identifying text ‘Extinguishing release’ and comes fitted with a 470Ω alarm resistor.

EXTINGUISHING RELEASE MANUAL CALL POINT

23908-H03 Extinguishing release manual call point

• Unique ‘plug & play’ installation concept

• Anti-Tamper facility

• Enhanced aesthetics

MCP ACCESSORIES

23908-H05 Spare test keys, pack of 10

23900-K215 Replacement flexible operating elements

23908-K027 Replacement glass elements, English/Arabic text, pack of 5

23908-H04 Replacement glass elements, English text, pack of 5

Door releaseEquipmentIn many buildings emergency fire doors are held in the open position using electromagnetic devices until the fire alarm sounds. On an alarm condition the control panel will initiate the release of these electromagnetic devices allowing the doors to close limiting the spread of smoke and fire through the building.

Applications include:

HospitalsLarge office buildingsHotels

ZOOM PRINT EXITPAGE 72/120 www.kfp.co.uk HOME CONTENTS

Page 73: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 72 73

Surface mounting door release unit with a holding force of 40kg, a release button is provided for manual release of the electromagnetic device. The unit also requires a floor mounted bracket.

ELECTROMAGNETIC DOOR RELEASE UNIT

• 24 Vdc 75mA

• 40Kg holding force

• Manual release button

• Spring ejector

• Door plate supplied

23911-H12 Magnetic door release unit

A range of sealed lead acid batteries that can be used with the Kidde range of control panels, each Kidde panel would require 2 x 12v batteries. Kidde panels are designed with space to install back-up batteries, if battery space is insufficient for the calculated battery requirements a separate battery enclosure would be required. Battery calculations are the responsibility of the system designer based on the panel loadings and battery back-up requirements determined by the specification. Dimensions of batteries are shown in brackets (H x W x L).

SEALED LEAD ACID BATTERIES

23911-H02 Floor bracket for magnetic door release unit

23911-K001 3Ah SLA batteries (134 x 67 x 60.5)

23911-H09 7Ah SLA batteries (151 x 65 x 94)

23911-H10 12Ah SLA batteries (151 x 98 x 95)

23911-H11 17Ah SLA batteries (181.5 x 77 x 167.5)

23911-K003 24Ah SLA batteries (166.5 x 176 x 112)

23911-K004 40Ah SLA batteries (197 x 165 x 170)

Sealed Lead AcidBatteriesKidde provide a range of rechargeable sealed lead acid batteries to provide back-up battery supplies for their range of control equipment.

ZOOM PRINT EXITPAGE 73/120 www.kfp.co.uk HOME CONTENTS

Page 74: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

DETECTION AND ALARM – INTRINSICALLY SAFE DETECTORS

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 74 75

IntrinsicallySafe Detectors

There are many places where an explosive mixture of air, gas or vapour is, or may be present either continuously, intermittently or as a result of an accident. These are defined as hazardous areas by BS EN 60079, the code of practice for installation and maintenance of electrical apparatus in potentially explosive atmospheres.

Hazardous areas are common in petroleum and chemical engineering plants and in factories processing and storing gases, solvents, paints and other volatile substances.

Electrical equipment for use in these areas needs to be designed so that it cannot ignite an explosive mixture, not only in normal operation but also in fault conditions. There are a number of methods available to achieve this but one of the most common is intrinsic safety.

Kidde offers both convential and intelligent smoke and heat detector ranges designed to be intrinsically safe, as they meet the requirements of the ATEX directive.

XP95 IS Intrinsically Safe DetectorsXP95 Intrinsically Safe (IS) detectors are a development of the well established intelligent XP95 range from Kidde. XP95 IS detectors feature all the benefits of the standard range, but are developed specifically for use in hazardous areas. The addresses of XP95 IS detectors are set by means of the patented XPERT card.

ZOOM PRINT EXITPAGE 74/120 www.kfp.co.uk HOME CONTENTS

Page 75: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 74 75

The XP95 IS Ionisation Smoke Detector uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers and causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm.

XP95 IS IONISATION SMOKE DETECTOR

• Responds well to fast-burning, flaming fires

• Designed to operate in a variety of environments

• Minimal effects from temperature, humidity atmospheric pressure and wind

23900-K046 XP95 IS Ionisation Smoke Detector

The XP95 IS Optical Smoke Detector works using the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely.

XP95 IS OPTICAL SMOKE DETECTOR

23900-K045 XP95 IS Optical Smoke Detector

• Responds well to slow-burning, smouldering fires

• Well suited for escape routes

• Unaffected by wind or atmospheric pressure

The XP95 IS Heat Detector operates by measuring temperature levels with a single thermistor network which gives a count output proportional to the external air temperature.

XP95 IS HEAT DETECTOR

• Ideal for environments that are dirty or smoky under normal conditions.

• Unaffected by wind or atmospheric pressure

23900-K047 XP95 IS Heat Detector

The XP95 IS Manual Call Point is based on the standard weatherproof model. It features an ‘interrupt’ facility to provide fast response to an alarm.

XP95 IS MANUAL CALL POINT – STANDARD TYPE

• Reports an alarm in under 0.2 seconds

• IP66 rated enclosure

23900-K048 XP95 IS Manual Call Point Standard without flap – Red

ZOOM PRINT EXITPAGE 75/120 www.kfp.co.uk HOME CONTENTS

Page 76: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

DETECTION AND ALARM – INTRINSICALLY SAFE DETECTORS

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 76 77

The MEDC style Manual Call Point is recommended for heavy duty applications. This model is made of glass-reinforced polyester.

XP95 IS MANUAL CALL POINT – MEDC STYLE

23900-K206 XP95 IS Manual Call Point MEDC Style – Break Glass – Red

The Protocol Translator and Galvanic Barrier are installed in the safe area ensuring integrity of communication between control equipment and field devices and safety within the limits of BASEEFA approvals.

PROTOCOL TRANSLATOR AND GALVANIC BARRIER

• Reports address in under 0.2 seconds

• IP66 rated enclosure

• Robust design

• Loop powered

• Translates voltage levels from a loop driver to be compatible with IS requirements.

23900-K139 XP95 Protocol Translator (single channel)

23900-K140 XP95 Protocol Translator (dual channel)

23900-K082 Galvanic Barrier

The Xp95 IS Mounting Base has been designed to accept only IS products. This ensures that standard detectors cannot inadvertently be fitted into an intrinsically safe system. EXPERT cards are supplied with all bases.

XP95 IS MOUNTING BASE

23900-K138 XP95 IS Mounting Base

• XPERT addressing

• One way fit

• Only accepts IS detectors

ZOOM PRINT EXITPAGE 76/120 www.kfp.co.uk HOME CONTENTS

Page 77: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 76 77

ORBIS IS Detector rangeOrbis IS is a range of conventional detectors which have been developed from the standard Orbis smoke and heat detectors Orbis IS is a range with modern styling and is electronically compatible with Apollo series 60 intrinsically safe conventional detectors.

Features include:

• Timesaver base®

• Patented FasTest® enabling functional testing in four seconds

• DirtAlert® indicates limit of drift compensation

• Tolerates extreme operating conditions: -40oC to +70oC

• False alarm reduction

The Orbis IS Multisensor Detector benefits from the same false alarm technology as the Optical Detector. It is a thermally enhanced smoke detector so will not give an alarm from heat alone.

ORBIS IS MULTISENSOR SMOKE DETECTOR

23900-K213 Orbis IS Multisensor Smoke Detector

• Reduces false alarms

• Sensitive to fast burning, flaming fires

• Improved sensitivity to black smoke

• Compensation for slow changes in sensitivity

• Algorithms for reliability of alarm

The Orbis IS Optical smoke detector works using the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely.

ORBIS IS OPTICAL SMOKE DETECTOR

• Reduces false alarms

• Recommended for early warning of fire in most areas

• Improved sensitivity to black smoke

• Compensation for slow changes in sensitivity

• Algorithms for reliability of alarm

23900-K214 Orbis IS Optical Smoke Detector

ZOOM PRINT EXITPAGE 77/120 www.kfp.co.uk HOME CONTENTS

Page 78: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

DETECTION AND ALARM – INTRINSICALLY SAFE DETECTORS

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 78 79

The Orbis IS Heat Detector monitors temperature by using a single thermistor network which provides a voltage output proportional to the external air temperature. The Orbis IS range incorporates seven heat detector classes to suit a wide range of operating conditions.

ORBIS IS HEAT DETECTOR

• Can be used for applications where smoke detectors are unsuitable.

• Ideal for environments that are dirty or smoky under normal conditions

• Reduced incidences of false alarms

• Increased reliability of detection

ORBIS IS HEAT DETECTOR

23900-K207 Rate-of-Rise MAT 50 C A1R - Standard

23900-K208 Static MAT 50 C A2S - Standard

23900-K209 Rate-of-Rise MAT 65 C BR - Standard

23900-K210 Static MAT 65 C BS - Standard

23900-K211 Rate-of-Rise MAT 80 C CR - Standard

23900-K212 Static MAT 80 C CS - Standard

MAT (Maximum Application Temperature)

The IS TimeSaver® Base is a completely new design that provides installers with an open working area with fixing holes shaped to allow a simple mounting procedure.

ORBIS IS TIMESAVER BASE

23900-K223 Orbis IS TimeSaver Base

• Grouped terminals to make wiring easy

• Two fixing centres

• LED alignment mark

• Detector locking mechanism

The dual channel galvanic isolator is essential when connecting IS devices to the zone circuit of a conventional fire alarm panel. The Galvanic isolator provides protection between the safe area where the panel is located and the hazardous area where the detectors are located. One dual channel galvanic isolator will protect up to two conventional detection zones.

DUAL CHANNEL GALVANIC ISOLATOR

23911-K055 Dual Channel Galvanic Isolator

• Straightforward ‘clip-on’ DIN-rail mounting

• Simplified installation and maintenance using plug-in connectors

ZOOM PRINT EXITPAGE 78/120 www.kfp.co.uk HOME CONTENTS

Page 79: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 78 79

Intrinsically Safe Audio/Visual SignallingA range of intrinsically safe sounders, beacons and sounder beacon combination units compatible with the Kidde range of control panels for use in hazardous environments.

An intrinsically safe beacon containing 6 high intensity LEDs and a prismatic lens for effective visual warning in hazardous area applications. The beacon is constructed from high impact ABS flame retardant material, weatherproof to IP65.

Important! The IS sounder must be used with a certified galvanic isolator or zener barrier.

SYREX IS BEACON – RED

23906-K008 Syrex IS beacon

• Rated for category 1 use

• ATEX approved

• Ex II 1G EExia IIC T4

A low current intrinsically safe sounder with audibility up to 100dB(A) at 1 metre and 49 switch selectable tones. The sounder is constructed from high impact ABS flame retardant material, weatherproof to IP65.

Important! The IS sounder must be used with a certified galvanic isolator or zener barrier.

SYREX IS SOUNDER

• Rated for category 1 use

• ATEX approved

• Ex II 1G EExia IIC T4

• Auto synchronised sound output

• Volume control

23906-K007 Syrex IS sounder 100dB(A)

ZOOM PRINT EXITPAGE 79/120 www.kfp.co.uk HOME CONTENTS

Page 80: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

DETECTION AND ALARM – INTRINSICALLY SAFE DETECTORS

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 80 81

A combination unit consisting of a sounder with audibility up to 100dB(A) at 1 metre, 49 switch selectable tones and high intensity LED beacon. The sounder beacon is constructed from high impact ABS flame retardant material, weatherproof to IP65.

SYREX IS-SB SOUNDER BEACON – RED LENS

23905-K022 Syrex IS-SB Sounder beacon, 100dB(A), Red lens

• Rated for category 1 use

• ATEX approved

• Ex II 1G EExia IIC T4

• Array of 6 high intensity LEDs

• Auto synchronised sound output

• Volume control

The shunt diode safety barrier is required when intrinsically safe sounders or beacons are connected to the sounder circuits on the Kidde range of control panels. The barrier provides protection between the safe area where the panel is located and the hazardous area where the sounders or beacons are located.

SHUNT DIODE SAFETY BARRIER

TBA Shunt diode safety barrier

• Straightforward ‘clip-on’ DIN-rail mounting

• Simplified installation and maintenance using plug-in connectors

ZOOM PRINT EXITPAGE 80/120 www.kfp.co.uk HOME CONTENTS

Page 81: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 80 81ZOOM PRINT EXITPAGE 81/120 www.kfp.co.uk HOME CONTENTS

Page 82: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 82 83

ASPIRATING SMOKE DETECTION

ZOOM PRINT EXITPAGE 82/120 www.kfp.co.uk HOME CONTENTS

Page 83: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Protecting assets worldwide

Developed in 1988, Kidde HSSD was the world’s first laser-based detector. They are in use worldwide, protecting valuable assets for institutions and companies as diverse as Windsor Castle, London Underground, BP and HSBC bank.

Protecting your investment

There are major benefits from a very early indication of incipient fire. The incident can be dealt with through local corrective measures such as powering down equipment or the use of hand extinguishers, avoiding unnecessary evacuation or suppressant release. Kidde HSSD systems can also be integrated into the main fire protection system, providing the first stage alert in an alarm organisation, with subsequent stages of alarm being set for suppressant release or evacuation.

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 82 83

Kidde High Sensitivity Smoke Detection systems (HSSD) are Aspirating Smoke Detection systems (ASD) designed to give very early indication of an incipient fire condition. This pre-emptive warning – before the transition into the flaming and heat stages – provides the time necessary to take corrective action and avoid the danger, damage and disruption to operations that a fire can cause. The Kidde HSSD equipment is simple to install, commission, operate and service. They have the highest levels of performance and reliability.

ZOOM PRINT EXITPAGE 83/120 www.kfp.co.uk HOME CONTENTS

Page 84: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

ASPIRATING SMOKE DETECTION

Where to use High Sensitivity Smoke Detection

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 84 85ZOOM PRINT EXITPAGE 84/120 www.kfp.co.uk HOME CONTENTS

Page 85: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Where appearances are important and preservation of priceless objects is a priority:

• Modern offices• Heritage buildings• Cathedrals• Museums• Libraries

Kidde HSSD provides total protection in critical applications:

• When downtime must be minimised• Where smoke is difficult to detect• In extreme environmental conditions• Where appearances are important• When extra time is necessary

In extreme environments that pose a problem to point type smoke detection:

• Power stations• Mines

• Offshore

Where smoke is difficult to detect in areas with high ceilings or high air flow:

• Atria• Warehouses• Cold storage• Indoor stadiums

When downtime must be minimized with high cost equipment:

• Clean rooms• Computer rooms• Telecommunications• Broadcast facilities

When extra time is necessary to effect safe and orderly evacuation:

• Airports• Underground railway systems• Hospitals• Theatres• Cinemas

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 84 85ZOOM PRINT EXITPAGE 85/120 www.kfp.co.uk HOME CONTENTS

Page 86: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

ASPIRATING SMOKE DETECTION

How High SensitivitySmoke Detection works

Stages of fire

Most fires start with some form of overheating. In this incipient stage, fine particles are released as the combustion process begins. The particles released atthe incipient stage of a fire may not be detected by point type smoke or heat detectors. In fact smouldering can continue for minutes, hours or even days before being detected by point type detectors. The incipient stage of smouldering fires provides the widest window of opportunity to detect and control the spread of fire.

The HSSD unit will go through various alarm thresholds in these early stages, long before point type smoke detectors will respond to the fire. Point type smoke detectors are designed to detect smoke at a level which

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 86 87

allows sufficient time for occupants to evacuate the area or building, although possibly not enough time to prevent damage to equipment. At this level there may also be an increased risk to anyone attempting to extinguish the fire.

HSSD units can be programmed to be up to 1000 times more sensitive than point type smoke detectors. Alarm levels can be set as high as 0.0025% obscuration per metre for clean areas and lower sensitivity for less controlled environments. This increased sensitivity allows the HSSD unit to detect and report an incident at the earliest possible stage, providing the time needed to help minimise or prevent fire damage.

ZOOM PRINT EXITPAGE 86/120 www.kfp.co.uk HOME CONTENTS

Page 87: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Aspirating detection

The HSSD detector is mounted either inside or outside the area. It draws air from the protected area using anaspirating fan which is housed in the detection unit. The pipe network contains sampling holes at predetermined locations through which the air is drawn.

HSSD detectors can protect areas up to 2000 square metres to BS5839, or between 500 to 750 square metres to BS6266, in high air flow conditions. The pipework is configured in various ways according to the application.Typically it will comprise of a pipe network with sampling points at intervals similar to point detection. It can also, for example, be arranged to monitor across air handling units or in ducts.

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 86 87

FACTORY

ELECTRONIC DATA PROCESSING

ZOOM PRINT EXITPAGE 87/120 www.kfp.co.uk HOME CONTENTS

Page 88: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

ASPIRATING SMOKE DETECTION

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 88 89

SENATORHigh SensitivitySmoke Detection

Senator High Sensitivity Smoke Detection embodies innovative features which depart from the accepted techniques for detectors operating at high sensitivity.

An extensive range of detection units and accessories make the Senator HSSD system one of the most flexible on the market.

The most important feature of the Senator range of detectors is the patented ‘artificial intelligence’ known as ClassiFire-3D.

Classifire-3DClassifire-3D is a process which controls all aspects of the system, ensuring the maximum safe sensitivity regardless of ambient conditions.

During an initial Fastlearn process, the detector samples the environment once each second and produces a histogram representing the ambient pollution level. The histogram fits a standard deviation curve, allowing statistical analysis of the data. Any normal curve can be divided into 3 equal width strips called a standard deviation with a known probability of a random event falling into each category. Classifire-3D uses this information to automatically set the correct sensitivity and alarm thresholds, determined by an acceptable frequency of false alarms.

After 24 hours ClassiFire-3D has sufficient data to set the alarm position at its best safe sensitivity. ClassiFire-3D continues to update the histogram for the entire lifetime of the detector.

Senator 25High sensitivity, small area detection unit

Senator 100High sensitivity, Medium area detection unit

Senator 200High sensitivity, large area detection unit

Senator ExHazardous area detection unit

Features• Wide range of detector types • High sensitivity provided by laser based forward light scatter for reliable early warning• Unique Classifire-3D perceptive artificial intelligence system• Laser Dust Discrimination (LDD) with a patented dust management and separator system • RS485 communications built into detector as standard for networking and remote communications• Addressable Protocol Interface card APICTM for connecting detector to Apollo protocol control panels• SenseNET network of 127 detectors • Command module available for central monitoring and display

ZOOM PRINT EXITPAGE 88/120 www.kfp.co.uk HOME CONTENTS

Page 89: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

SENATOR 25

30671-KID SENATOR 25 including docking station

SENATOR 100

30760-KID SENATOR 25 including docking station and relay/input card

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 88 89

Senator 25 High Sensitivity Smoke Detector provides cost effective, very early warning smoke detection in small area applications. A single sampling pipe of 50m maximum length can be connected to the detector unit.

Senator 25 is supplied in a docking station allowing easy first fix installation of sampling pipes and cables. Volt free change over relays provide the facility to interface the Senator 25 into the site fire alarm system. Programmable options such as alarm levels and delays, latching or non-latching alarms, high and low airflow levels are available when using a PC and the Senator Remote programming software. The Senator 25 is compatible with the SenseNET network and Command modules. Approved to EN54.20.

Technical specification Dimensions 140W x 200H x 85DWeight 1.85Kg Enclosure rating IP50Operating temperature -10 to 60oCOperating humidity 0 to 90% RH, non condensingVoltage requirements 21.6 to 26.4V dcQuiescent current 250mAIndications Fire, Fault and OKRelay outputs 2 x 500mA @ 30V dc – Alarm, Fault (energised) Additional relays available when using Relay/Input card Inputs RS485 for network connections APIC address terminals for addressable loop (Requires APIC addressable interface card)Sensitivity range Min 25%, Max 0.02% ob/m

Senator 100 High Sensitivity Smoke Detector provides cost effective, very early warning smoke detection in medium size applications. Two 50m sampling pipes or a single pipe of 100m maximum length can be connected to the detector unit.

Senator 100 is supplied in a docking station allowing easy first fix installation of sampling pipes and cables. Volt free change over relays provide the facility to interface the Senator 100 into the site fire alarm system. Programmable options such as alarm levels and delays, latching or non-latching alarms, high and low airflow levels are available when using a PC and the Senator Remote programming software. The Senator 100 is compatible with the SenseNET network and Command modules. Approved to EN54.20.

Technical specification

Dimensions 300W x 220H x 90DWeight 3.8Kg Enclosure rating IP50Operating temperature -10 to 60oCOperating humidity 0 to 90% RH, non condensingVoltage requirements 21.6 to 26.4V dcQuiescent current 400mAIndications Fire, Fault and OKRelay outputs 2 x 500mA @ 30V dc – Alarm, Fault (energised) Additional relays available when using Relay/Input cardInputs RS485 for network connections APIC address terminals for addressable loop (Requires APIC addressable interface card)Sensitivity range Min 25%, Max 0.02% ob/m

30672-KID SENATOR 100 including docking station

30764-KID SENATOR 100 including docking station and relay/input card

ZOOM PRINT EXITPAGE 89/120 www.kfp.co.uk HOME CONTENTS

Page 90: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

ASPIRATING SMOKE DETECTION

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 90 91

SENATOR 200

30621-KID SENATOR 200 detector

SENATOR 200WITH COMMAND MODULE

The Senator 200 High Sensitivity Smoke Detector provides cost effective, very early warning smoke detection in large area applications. Four sampling pipes of 50m maximum length each or two sampling pipes of 100m maximum length each can be connected to the detector unit.LCD display and cursor controls are provided which allow programming of the unit without any additional programmers or PC. Volt free change over relays provide the facility to interface the Senator 200 into the site fire alarm system. Programmable options such as alarm levels and delays, latching or non-latching alarms, airflow normalisation, high and low airflow levels and automatic sensitivity setup are available in the programming options. The Senator 200 is available in a number of variants and is compatible with the SenseNET network.Approved to EN54.20.

Technical specification Dimensions 427W x 372H x 95DWeight 5.2Kg Enclosure rating IP50Operating temperature -10 to 60oCOperating humidity 0 to 90% RH, non condensingVoltage requirements 21.6 to 26.4V dcQuiescent current 300mA (Fan speed 1), 470mA (Fan speed 8), 750mA (Fan speed 16)Indications LCD status display LEDs : Aux Alarm, Pre-Alarm, Fire Alarm, Fire 2, Fault, OK, 26 segment bargraphRelay outputs 5 x 500mA @ 30V dc – Fire 1, Fire 2, Pre-alarm, Aux alarm, Fault (energised)Inputs RS485 for network connections APIC address terminals for addressable loop (Requires APIC interface card)Sensitivity range Min 25%, Max 0.02% ob/m

This variant of the Senator 200 detector unit is provided with a built in command module, allowing it to provide single location display, control and interfacing options for up to 127 networked Senator detectors.

A larger LCD display is provided to display more information relating to the SenseNET network. Approved to EN54.20.

Technical specification

Dimensions 427W x 372H x 95DWeight 5.3Kg Enclosure rating IP50Operating temperature -10 to 60oCOperating humidity 0 to 90% RH, non condensingVoltage requirements 21.6 to 26.4V dcQuiescent current 750mA (Fan speed 1), 920mA (Fan speed 8), 1.5A (Fan speed 16)Indications LCD status display LEDs : Aux Alarm, Pre-Alarm, Fire Alarm, Fire 2, Fault, OK, 26 segment bargraphRelay outputs 5 x 500mA @ 30V dc – Fire 1, Fire 2, Pre-alarm, Aux alarm, Fault (energised)Inputs RS485 for network connections APIC address terminals for addressable loop (Requires APIC interface card)Sensitivity range Min 25%, Max 0.02% ob/m

30620-KID SENATOR 200 detector with Command Module

ZOOM PRINT EXITPAGE 90/120 www.kfp.co.uk HOME CONTENTS

Page 91: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

SENATOR 200STEEL ENCLOSURE

30706-KID SENATOR 200 detector – steel enclosure

SENATOR 200WITH MINIMUM DISPLAY

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 90 91

Identical to 30621-KID the rugged sheet steel enclosure provides added protection for the Senator 200 detector in harsh environments. Approved to EN54.20.

This is an economy version of the Senator 200 detector provided in a rugged sheet steel enclosure. The unit provides basic LED indications for alarm, fault and normal status. Programming is available through RS485 serial connection or Command Module.Approved to EN54.20

Technical specification Dimensions 427W x 372H x 95DWeight 5.3Kg Enclosure rating IP50Operating temperature -10 to 60oCOperating humidity 0 to 90% RH, non condensingVoltage requirements 21.6 to 26.4V dcQuiescent current 450mA @ 24V dc at fan speed 8Indications LED indications “OK”, “Fault” and “Fire”Relay outputs 5 x 500mA @ 30V dc – Fire 1, Fire 2, Pre-alarm, Aux alarm, Fault (energised)Inputs RS485 for network connections APIC address terminals for addressable loop (Requires APIC addressable interface card)Sensitivity range Min 25%, Max 0.02% ob/m

30710-KID SENATOR 200 with minimum display

SENATOR 200WITH COMMAND MODULE STEEL ENCLOSURE

30707-KID SENATOR 200 detector with Command Module – steel enclosure

Identical to 30620-KID the rugged sheet steel enclosure provides added protection for the Senator 200 detector with Command Module in harsh environments. Approved to EN54.20.

ZOOM PRINT EXITPAGE 91/120 www.kfp.co.uk HOME CONTENTS

Page 92: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

ASPIRATING SMOKE DETECTION

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 92 93

SENATOR EX

30731-KID SENATOR Ex

SENATOR STAND ALONECOMMAND MODULE

Senator Ex is a reliable very high sensitivity smoke detector for use in Hazarduous areas. The detector is supplied in either a cast aluminium or stainless steel enclosure. Approvals: ATEX rated EEx d IIB +H2 T3, equipment group 2 (Zones 1, 2 and 3), group gases A and B + Hydrogen.An external particle filter is provided allowing ease of maintenance without declassifying the area.Upgradeable Fire and Fault relay outputs are available for interfacing to other fire alarm equipment.

Technical specification Dimensions 400W x 200H x 165D inc. flame arrestorsWeight 8.5Kg Enclosure rating IP65Operating temperature -10 to 60oCOperating humidity 0 to 90% RH, non condensingVoltage requirements 21.6 to 26.4V dcQuiescent current 1.1A @ 24V dcIndications LED indications “OK”, “Fault” and “Fire”Relay outputs 2 x 500mA @ 30V dc – Fire, Fault (energised)Inputs RS485 for network connections APIC address terminals for addressable loop (Requires APIC addressable interface card)Sensitivity range Min 25%, Max 0.0015% ob/m

Senator Command Module provides a single location display, control and interfacing option for systems of up to 127 detectors. The Command module allows global programming of all detector functions simultaneously.

An internal bargraph automatically displays the status of the detector with the highest alarm level. The Command Module is provided with an integral serial interface programmable for TAP text messages/Paging or BACnet BMS communications. Available with or without an internal power supply.

Technical specification Dimensions 427W x 372H x 95DWeight 6.2Kg (10.1Kg with batteries) Enclosure rating IP50Operating temperature -10 to 60oCOperating humidity 0 to 90% RH, non condensingVoltage requirements without PSU - 21.6 to 26.4V dc with PSU – 230V input, mains fuse 3A Quiescent current 250mA @ 24V dcIndications LCD status display LEDs : Aux Alarm, Pre-Alarm, Fire Alarm, Fire 2, Fault, OK, 26 segment bargraph Relay outputs 5 x 500mA @ 30V dc – Fire 1, Fire 2, Pre-alarm, Aux alarm, Fault (energised)Inputs RS485 for network connections APIC address terminals for addressable loop (Requires APIC addressable interface card)

30623-KID SENATOR Command Module with PSU

30732-KID SENATOR Ex – stainless steel enclosure 30624-KID SENATOR Command Module without PSU

ZOOM PRINT EXITPAGE 92/120 www.kfp.co.uk HOME CONTENTS

Page 93: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

SENATOR STAND ALONECOMMAND MODULE STEEL ENCLOSURE

30708-KID SENATOR Command Module with PSU – steel enclosure

SENATOR REMOTE DISPLAY UNIT (RDU)

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 92 93

Identical to 30623-KID and 30624-KID the rugged sheet steel enclosure provides added protection for the Senator Command Module in harsh environments.

The Senator remote display unit connects to the Senator range of detectors using the RS485 data bus and mimics the LED status indications of the detector. The RDU monitors the status of a single detector.

More than one RDU can be allocated to a single detector. The RDU can be mounted in either a single wall mounted enclosure or a 19” rack enclosure. Up to 8 RDUs can be mounted in a single 19” sub frame. An optional relay board is available for use with the RDU.

Technical specification Dimensions 3U HighOperating temperature -10 to 60oCOperating humidity 0 to 90% RH, non condensingVoltage requirements Nominal 24V dc, range 18-30V dc Quiescent current 40mAIndication LEDs : Aux Alarm, Pre-Alarm, Fire 1, Fire 2, Fault, OK, 26 segment bargraph

30802-KID SENATOR Remote Display Unit (RDU)

SENATOR 19”RACK MOUNT COMMAND MODULE

30814-KID SENATOR 19” Rack mount Command Module

Senator command module which is designed to be installed in a 19” rack type enclosure.

Technical specification

Dimensions 3U High x 80mm deepOperating temperature -10 to 60oCOperating humidity 0 to 90% RH, non condensingVoltage requirements Nominal 24Vdc, range 18-30V DC Quiescent current 40mA

30709-KID SENATOR Command Module without PSU – steel enclosure

ZOOM PRINT EXITPAGE 93/120 www.kfp.co.uk HOME CONTENTS

Page 94: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

ASPIRATING SMOKE DETECTION

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 94 95

SENATOR REMOTE DISPLAY UNITRELAY BOARD

30803-KID SENATOR Remote Display Unit Relay board

SENATOR RDU ENCLOSUREExample fitted with 24 RDUs

This is an optional relay board which can be used with the Senator RDU to provide Volt Free Changeover Contacts for signalling to other equipment. Five relays are provided for Fire 1, Fire 2, Pre-alarm, Aux Alarm and Fault (energised).

Technical specification

Maximum switching voltage 200 Volts dcMaximum switching current 0.5 Amp

A low profile 150mm deep, 9U high enclosure with a glazed lockable outer door and space for installing up to 24 RDUs and relay cards. A suitable 24 Vdc power supply is required.

SENATOR RDU WALL MOUNTING ENCLOSURE

30817-KID SENATOR RDU wall mounting enclosure

Small steel enclosure for wall mounting a single Senator Remote Display Unit and optional relay board.

Technical specification

Dimensions 80W x 150H x 60D

30824-KID SENATOR RDU enclosure

30812-KID Blank In-fill plates for spare slots

30813-KID In-fill plate with RS232 port for PC interface

30823-KID SENATOR RDU enclosure including Command Module

30812-KID Blank In-fill plates for spare slots

30813-KID In-fill plate with RS232 port for PC interface

SENATOR RDU ENCLOSUREINCLUDING COMMAND MODULEExample fitted with 16 RDUs

A low profile 150mm deep, 9U high enclosure with a glazed lockable outer door containing a Senator Command Module and space for installing up to 16 RDUs and relay cards. A suitable 24 Vdc power supply is required.

ZOOM PRINT EXITPAGE 94/120 www.kfp.co.uk HOME CONTENTS

Page 95: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

SENATOR RELAY/INPUT CARD

30436-KID SENATOR Relay/Input card

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 94 95

The Senator Relay/Input card can be fitted into the Senator 25 and 100 detectors to provide an additional five relay outputs for signalling to other equipment. Three inputs are provided on the card that can be programmed for remote reset, isolate, classifire override or PSU fault monitoring.

APIC – APOLLO ADDRESSABLE INTERFACE CARD

30430-KID APIC – Apollo card

The APIC – Apollo Addressable Interface card can be fitted internally to any Senator detector unit or Command Module and allows connection to the addressable loop of any Apollo protocol control panel. A single APIC may be used in Multi Address mode when installed inside a command module for signalling up to 127 detectors onto the addressable loop reducing costs on larger systems.

RDU 19” SUB FRAME

30814-KID RDU 19” sub frame

A low profile 3U high sub rack with space for mounting up to 8 RDUs and relay cards. A suitable 24v power supply is required.

SENSENET CONTROL UNIT

30805-KID SenseNET Contact monitor

The SenseNET control unit interfaces the SenseNET detector network with the PC serial port. The control unit comes complete with connecting cables, power supply and PC software.

30812-KID Blank In-fill plates for spare slots

30804-KID SenseNET control unit

SENSENET CONTACT MONITOR

The SenseNET contact monitor allows monitoring of up to 7 clean contacts from other systems through the SenseNET network.

Technical specification

Maximum input voltage 18 – 30 VdcMaximum operating current 20mAOperating temperature -10 to +60oCOperating humidity 0 – 90% RH Non condensing

ZOOM PRINT EXITPAGE 95/120 www.kfp.co.uk HOME CONTENTS

Page 96: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

ASPIRATING SMOKE DETECTION

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 96 97

SENSENET (RS485/RS232 CAT5 CONVERTER)

30811-KID SenseNET (RS485/RS232 CAT5 converter

PS25 INTELLIGENT 2.5 AMP POWER SUPPLY – EN54-4 COMPLIANT

This unit allows the SenseNET network to connect to and send data across a CAT5 Local Area Network (LAN).

The PS25 power supply is designed to provide a versatile solution for powering aspirating smoke detectors. A high capacity 2.5 Amp power supply provides current for ‘day to day’ system operation while charging back-up batteries. The PS25 is capable of providing 24hr mains fail battery back-up using industry standard sealed lead acid batteries. A relay output is provided for remote monitoring of mains fail and battery faults.

Technical specification

Enclosure Steel, neutral colourDimensions 383W x 408H x 97DWeight 6Kg Input voltage 200 to 250V AC 50/60HzMax current consumption 0.9A @ 200V ACOperating temperature -5 to 40oCOperating humidity 0 to 90% RHOutput voltage 27V dc +/- 1%Output current Maximum 2.5ABattery capacity 2 x 12V 17Ah

PC INTERFACE

30816-KID PC interface

This is the interface module only part of the SenseNET control unit, part no. 30804-KID No software or dongle included.

30826-KID PS25 Power Supply

30419-KID Senator serial cable

SENATOR SERIAL CABLESENATOR BUS ISOLATOR

30754-KID Senator bus isolator

Provides SenseNET network short circuit isolation for unprotected devices.

For use in conjunction with the Senator remote software. The serial cable provides connection between the Senator detector or command module and a PC.

ZOOM PRINT EXITPAGE 96/120 www.kfp.co.uk HOME CONTENTS

Page 97: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

SENSENET SOFTWARE CD AND DONGLE

30250-KID Software CD and dongle

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 96 97

Software provides central indication and control for the SenseNET network.

SENATOR AIR HEATER BOX

30422-KID Senator air heater box

For use with Senator detectors, where the sampling points are installed in low temperature applications i.e. cold stores. The heater box warms the air before it reaches the detector unit.

Technical specification

Enclosure Sheet SteelHeating element Self regulating 230 VAC, 60/200 watts

WIRE BURN TEST RIG

The test rig is used to commission systems designed to meet the requirements of BS6266.

WIRE BURN TEST WIRE

21888-K030 Smoke pellets

10 x 0.1mm PVC coated wire (white) supplied on a 100m reel. This is used in conjunction with the wire burn test rig.

30051-KID Wire burn test rig

21888-K033 Wire burn test wire

SMOKE PELLETS

PH standard smoke pellets ideal for testing large pipework systems to the requirements of BS5839 part-1. Each tube contains 6 x 13g pellets with a 40 sec burn time.

ASPIRATOR WITH THERMOSTAT

30425-KID Aspirator with thermastat

This is used in conjunction with the Senator air heater box, part no. 30422-KID and allows monitoring of the heater element. The aspirator with thermostat is designed to replace the existing fan in the Senator 200. A volt free contact on the aspirator can be wired in series with the Senator 200 fault relay.

ZOOM PRINT EXITPAGE 97/120 www.kfp.co.uk HOME CONTENTS

Page 98: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

ASPIRATING SMOKE DETECTION

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 98 99

HART High SensitivitySmoke Detection

The HART High Sensitivity Smoke Detection (HSSD) system is optimised in terms of performance, capability, reliability and serviceability. Featuring simplicity in both system configuration and operation, HART has a clean, aesthetic design and is compact and lightweight.

HART MiniDesigned to provide area coverage up to 800m2. Top and bottom pipe entry options are available, and a single LED provides status indication.

HART XLDesigned to provide area coverage up to 2000m2, HART XL offers complete flexibility – just four sub units provide all the configuration options.

Individual particle countingHART HSSD operates on a laser-based particle counting principle. The smoke particles pass through a focussed laser beam with scattered light from individual particles being picked up by a photodiode sensor and converted to an electrical pulse. The pulse rate is electronically counted and measured against alert and alarm thresholds. Information regarding smoke levels and alarm thresholds can be presented on a Hart XL LCD. Alarm and fault signals can easily be transmitted to a Fire Alarm control panel or BMS through volt free relays. Since the sensing process takes place in the beam in the centre of the sampling chamber, the detection performance is unaffected by any build up of particulate on the walls of the chamber over time. For this reason air filtering is unnecessary, which is an important maintenance benefit.

Features• Laser based particle counting • Elegant, compact, lightweight design• No particle filters required for electronic data processing applications• No recalibration during lifetime of detector• Complete flexibility – four basic sub units provide installation options• On site sensitivity selection 0.0025%/m to 1%/m• LaserNet networking options• Modular design for fast and easy servicing• Configurable for integral or remote display options• Attachable power supply and battery back up unit• Individual pre-alarm and alarm levels• Optical Self-Test (OST) which positively checks the condition

of the detector• Range of worldwide product approvals

Benefits• High immunity smoke discrimination• Simple, low-cost maintenance• High reliability• High immunity to unwanted alarms• Long term stability• No recalibration required

HART XL with optional display module and power supply

ZOOM PRINT EXITPAGE 98/120 www.kfp.co.uk HOME CONTENTS

Page 99: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 98 99

The HART mini High Sensitivity Smoke Detector provides cost effective, very early warning smoke detection in small areas up to 800m2. Single tri-colour LED provides indication of the detector status. Single pushbutton provides isolation and reset controls. The HART mini is supplied in two variants for top or bottom pipe entry to suit the installation. Volt free change over relays provide the facility to interface the HART mini into the site fire alarm system. Programmable options such as alarm levels and delays, latching or non-latching alarms, airflow normalisation, high and low airflow levels and automatic sensitivity setup are available when using a PC and the LaserNET programming software.

Technical specification Enclosure Light grey polycarbonate with steel mounting plateDimensions 222W x 226H x 81DWeight 2.2Kg Enclosure rating IP31 (NEMA-1)Operating temperature 0 to 49oCOperating humidity 10 to 93% RH, non condensing at 40oCVoltage requirements 18 to 30V dc (24V dc nominal)Quiescent current 230mAAlarm current 246mAIndications Tri-colour LED – Alarm, Pre-alarm, Fault, IsolatedControls Push button – Reset, IsolateRelay outputs 3 x 2A @30V dc – Pre-alarm, Alarm, Fault (energised)Inputs Remote reset, RS485 networkSensitivity range 0.0025 to 1.0% obscuration per metreAir inlet ¾” threaded NPT (3/4” to 25mm adaptor supplied)

HART MINI DETECTOR

53836-K205K-00 HART Mini - bottom pipe entry

The HART XL High Sensitivity Smoke Detector provides very early warning smoke detection in areas up to 2000m2 in area. Single tri-colour LED provides indication of the detector status, no user controls are provided in the HART XL detector although an optional display module is available. Volt free change over relays provide the facility to interface the HART XL into the site fire alarm system. Programmable options such as alarm levels and delays, latching or non-latching alarms, airflow normalisation, high and low airflow levels and automatic sensitivity setup are available when using a PC and the LaserNET programming software. The HART XL can be mounted either way up allowing top or bottom pipe entry and is provided with the necessary adaptors for fixing an exhaust pipe.

Technical specification Enclosure Light grey polycarbonate with steel mounting plateDimensions 320W x 228H x 108DWeight 3.4Kg Enclosure rating IP31 (NEMA-1)Operating temperature 0 to 52oCOperating humidity 10 to 93% RH, non condensing at 40oCVoltage requirements 18 to 30V dc (24V DC nominal)Quiescent current 315mAAlarm current 380mAIndications Tri-colour LED – Alarm, Pre-alarm, Fault, Isolated, Optional Display ModuleControls Optional Display ModuleRelay outputs 6 x 2A @30V dc – Pre-alarm 1, Pre-alarm 2, Alarm 1, Alarm 2, Isolate, Fault (energised)Inputs RS485 networkSensitivity range 0.0025 to 1.0% obscuration per metreAir inlet ¾” threaded NPT (3/4” to 25mm adaptor supplied)Air exhaust 1” threaded NPT (1” to 25mm adaptor supplied)

HART XL DETECTOR

53836-K183 HART XL detector53836-K205K-01 HART Mini - top pipe entry

ZOOM PRINT EXITPAGE 99/120 www.kfp.co.uk HOME CONTENTS

Page 100: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

ASPIRATING SMOKE DETECTION

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 100 101

The HART XL self contained power supply can power a single detector, with or without a display. The PSU housing can fit 2 x 12v 2.0Ah batteries (Yuasa NP2-12) which will provide up to 4hrs standby power.

Technical specification Enclosure Light grey polycarbonate with steel backboxDimensions 317W x 114H x 105DWeight 3.1Kg Input voltage 90 to 260 V AC 50/60HzMax input current 1AOperating temperature 0 to 52oC with no de-ratingOperating humidity 10 to 95% RH, non condensingOutput voltage 28.75V dcOutput current Maximum 1AFault relay Normally closed contact 1 Amp @ 28V dcBattery capacity 2 x 12V 2.0Ah (Yuasa NP2-12)

HART XL SELF CONTAINED POWER SUPPLY

53836-K185 HART XL Self Contained Power Supply

23911-K051 12V 2.0AH Battery (2 required)

The PS25 power supply is designed to provide a versatile solution for powering aspirating smoke detectors. A high capacity 2.5 Amp power supply provides current for ‘day to day’ system operation while charging back-up batteries. The PS25 is capable of providing 24hr mains fail battery back-up using industry standard sealed lead acid batteries. A relay output is provided for remote monitoring of mains fail and battery faults

Technical specification Enclosure Steel, neutral colourDimensions 383W x 408H x 97DWeight 6Kg Input voltage 200 to 250V AC 50/60HzMax current consumption 0.9A @ 200V ACOperating temperature -5 to 40oCOperating humidity 0 to 90% RHOutput voltage 27V dc +/- 1%Output current Maximum 2.5ABattery capacity 2 x 12V 17Ah

PS25 INTELLIGENT 2.5 AMP POWER SUPPLYEN54-4 APPROVED

30826-KID PS25 Power Supply

The HART XL Display module provides the display of status information and functional controls for the HART XL detector. The Display Module can be mounted within the detector unit or remotely up to 1km away. Clear information regarding the detector status and settings are provided on the Large LCD. Pushbutton controls are provided for basic operations with password restricted access. Language variants are available.

Technical specification Enclosure Light grey polycarbonate with steel mounting plateDimensions 122W x 145H x 38DWeight 0.5Kg Enclosure rating IP31 (NEMA-1)Operating temperature 0 to 52oCOperating humidity 10 to 95% RH, non condensing at 40oCVoltage requirements 18-36V dc - supplied from detector unitQuiescent current 30mA normal (100mA with backlight on)Indications Large LCD Tri-colour LED – Alarm, Pre-alarm, Fault, IsolatedControls 4 x Cursor keys, 1 x Enter keyCommunications RS485

HART XL DISPLAY MODULE

53836-K182 HART XL Display Module

ZOOM PRINT EXITPAGE 100/120 www.kfp.co.uk HOME CONTENTS

Page 101: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 100 101

All HART HSSD detectors are programmed using LaserNet software and the HART programming lead. Each HART Detector is shipped with a CD containing this software but the programming lead must be purchased separately. The software enables the user to monitor interrogate, configure and download system data.

LASERNET PROGRAMMING SOFTWARE

36215-K228 HART CD

53800-H08 HART Programming Lead

The HART XL Apollo interface card can be installed within the HART XL detector enabling it to interface to any Apollo protocol control panel providing Pre-alarm, Alarm and Fault levels. When interfaced to the Kidde Vega control panel additional monitoring functions are available.

Technical specification Connections Loop in +ve/-ve, Loop out +ve/-veAddress 8 way DIL switchLoop current 2mAIndications Power on LED Loop comms OK LEDOperating temperature 0 to 52oCOperating humidity 10 to 95% RH, non condensing at 40oC

HART XL APOLLO INTERFACE CARD

44782-K167 HART XL Apollo Interface Card

The Remote interface card provides the facility to monitor and control the operation of the HART XL detector without the use of LaserNET programming software or Display Module. A monitored input allows the monitoring of external Reset, Silence and Isolate switches. The Remote interface plugs directly into the termination board within the HART XL detector

Technical specification Inputs Monitored inputOutputs 4-20mA output for smoke and airflow signals 0-12mA output for smoke and airflow signals Airflow fault relay – 2A @ 30V dc Quiescent current 50mAMax current 90mAOperating temperature 0 to 52oCOperating humidity 10 to 95% RH, non condensing at 40oC

HART REMOTE INTERFACE CARD

44782-K165 HART XL Remote Interface Card

ZOOM PRINT EXITPAGE101/120 www.kfp.co.uk HOME CONTENTS

Page 102: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

ASPIRATING SMOKE DETECTION

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 102 103

ASD detector range: potential market sectors

Senator 25 Senator 100 Senator 200 Senator Ex Hart XL Hart Mini

Prison Cells ● ● Heritage Buildings ● ● ●Retail Outlet ● ●Ceiling Voids ● ● ● ● ●Atrium (10m) ●Atrium (10m+) ● ● ● ● ●

Telephone Exchange ● ● ● ● ● EDP Room ● ● ● ● Clean Room ● ● ● ● ●Small Comms Room ● ● ●Plant Room

Cabinets ● ● ●Trains ● ● ● ● Wind Generators ● ●

Cold Stores ● ● ● ● ●Wash Down Areas ● ● ● ● ●Factory ● ● ● ● ● WareHouse ● ● ●Under Mezzanine Area ● ● ● ● ●

Explosion Risk (Gas) ●

ASD Detector Range

Senator 25 Senator 100 Senator 200 Senator Ex Hart XL Hart Mini

Pipe Length (total) 50m 100m 250m 50m 2x100 or 4x50m 80m (2x50m capable)Qty Pipes 1 2 4 1 1+multiple 1+2 branches branchesQty Holes: Class A 10 20 20 10 40 40Qty Holes: Class B 10 20 40 10 40 40Qty Holes: Class C 10 20 100 10 100 100Sensitivity: obsc/m 0.03%-25% 0.03%-25% 0.03%-25% 0.03%-25%l 0.025%-1% 0.025%-1%

RS485 Comms ● ● ● ● ● Addressable interface Card ❉ ❉ ❉ ❉ ❉

Firmware Upgradeable ● ●Configure with PC ● ● ● ● ● ●Configure without PC ❉

Fix ClassiFire ClassiFire Override ❉ ❉ ● ❉ Remote Reset ❉ ❉ ● ❉ ❉ ●

Outputs: Fire1 ● ● ● ● ● Outputs: Fire2 ❉ ❉ ● ❉ ● ●Outputs: Prelarm ❉ ❉ ● ❉ ● ● Outputs: Aux ❉ ❉ ● ❉ ●Outputs: Fault ● ● ● ● ● ●

❉ via optional card

ZOOM PRINT EXITPAGE 102/120 www.kfp.co.uk HOME CONTENTS

Page 103: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 102 103

SnifferPipeSnifferPipe is a comprehensive range of high quality pipe, fittings and accessories for the Senator and HART aspirating smoke detection systems.

SnifferPipe and fittings are manufactured from red Acrylonitrile Butadiene Styrene (ABS). The physical properties of ABS make the pipe and fittings ideal for aspirating pipework systems:

• Robust construction to reduce mechanical damage

• Smooth bore to facilitate air flow to the detector

• Lightweight and easy to install• High resistance to chemicals and

weathering• Suitable for use over a wide

temperature range. - 40 to +80° C

The red colour and clear markings ensure the air sampling pipe network is easily identifiable from other services.

The SnifferPipe range is based on pipework with standard metric outside diameter of 25mm.

AIR SAMPLING PIPE 25mm O.D. 3 METRE LENGTH

21888-K016 Air sampling pipe 25mm O.D. 3 metre length

STRAIGHT SOCKET

21888-K020 Straight Socket

90° ELBOW

21888-K017 90° Elbow

45° ELBOW

21888-K018 45° Elbow

EQUAL TEE

21888-K018 Equal Tee

END CAP

21888-K021 End Cap

UNION SOCKET

21888-K024 Union Socket

PIPE CLIP

21888-K025 Pipe Clip

ZOOM PRINT EXITPAGE 103/120 www.kfp.co.uk HOME CONTENTS

Page 104: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

ASPIRATING SMOKE DETECTION

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 104 105

PARTICLE SEPARATOR

21888-K063 Particle Separator

FLUSH AIR SAMPLING POINT CAPILLARY KIT

DISCRETE 10mm CAPILLARY SAMPLING POINT

21888-K068 Discrete 10mm Capillary Sampling Point

10mm NYLON CAPILLARY TUBE

21888-K062 10mm Nylon Capillary tube

25mm/10mm COMPRESSION ADAPTOR

TBA 25mm/10mm Compression adaptor

The particle separator can assist with keeping the detector clean when installed in dirty and dusty environments. The unit is supplied with two 25mm union sockets to allow installation into the sampling pipe. Foam elements inside the detector can easily be replaced as necessary.

CONICAL AIR SAMPLING POINT CAPILLARY KIT

21888-K065 Conical Air Sampling Point Capillary Kit

The conical air sampling point capillary kit can be used where discrete detection is required. The capillary kit can be connected to sampling pipe which is installed in a ceiling void out of view with the conical sample point fixed through the ceiling to sample from the protected area. The capillary tube is supplied 2m in length but can be cut accordingly on site. A 25mm compression adaptor allows it to be used with standard pipework fittings i.e. Elbow, Equal Tee, or Socket.

21888-K064 Replacement Foam Elements for Particle Separator

21888-K066 Flush Air Sampling Point Capillary Kit

The flush air sampling point capillary kit can be used where discrete detection is required. The capillary kit can be connected to sampling pipe which is installed in a ceiling void out of view with the flush sample point fixed through the ceiling to sample from the protected area. The capillary tube is supplied 2m in length but can be cut accordingly on site. A 25mm compression adaptor allows it to be used with standard pipework fittings i.e. Elbow, Equal Tee, or Socket

The discrete 10mm capillary sampling point can be used where discrete detection is required. The capillary sample point will fit on the end of the nylon capillary tube and can then be drilled with the correct sample hole size.

SAMPLING TEST POINT

21888-K067 Sampling test point

The sampling test point can be used where access to the sampling points for testing is difficult or restricted. The test point can be installed at an accessible location to allow easy smoke testing of the system during its service.

Provided in a 30 metre reel the nylon capillary tube allows customers to create their own capillary sample kits, where existing kits aren’t suitable.Colour: Natural

The compression adaptor allows 10mm capillary tube to be connected into standard 25mm fittings i.e. Elbow, Equal Tee and Sockets.

ZOOM PRINT EXITPAGE 104/120 www.kfp.co.uk HOME CONTENTS

Page 105: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 104 105

PIPE CUTTERS

21888-K028 Pipe Cutters

Ratchet action cutters for plastic pipe, can cut pipe up to 42mm in diameter.

PIPE WARNING LABEL

39155-H11 Pipe warning label

PIPE SAMPLING POINT LABEL

36215-K326 Pipe sampling point label

The pipe warning label is used to identify pipework as aspirating pipework to prevent damage to the system, supplied as a 100 label roll.

The pipe sampling point label is used to identify the location of sampling points drilled into the sampling pipework.

ZOOM PRINT EXITPAGE 105/120 www.kfp.co.uk HOME CONTENTS

Page 106: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 106 107

ALARMLINE LINEAR HEAT DETECTION

ZOOM PRINT EXITPAGE 106/120 www.kfp.co.uk HOME CONTENTS

Page 107: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 106 107

Kidde Linear Heat Detection (LHD) Systems are cable based systems that provide economical temperature monitoring at the precise point of risk. The system is reliable, flexible and has the ability to detect abnormal temperature variances before it develops into a fire situation. Kidde Fire Protection’s comprehensive LHD portfolio allows a vast range of both commercial and industrial fire and overheat risks to be protected, in ambient temperatures of – 40°C to + 200°C. Alarmline sensor cables may be installed within hazardous environments using approved I.S. barriers for simple apparatus. All Alarmline cables supplied in increments of 100m up to 1000m.

Benefits

• Detection at point of risk.• Continuous operation within the most adverse environmental conditions.• Electrical and mechanical flexibility.• Internationally proven “in service” experience.• Integration with all types of central control systems.

ZOOM PRINT EXITPAGE 107/120 www.kfp.co.uk HOME CONTENTS

Page 108: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

ALARMLINE LINEAR HEAT DETECTION

Where to use Alarmline Linear Heat Detection

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 108 109ZOOM PRINT EXITPAGE 108/120 www.kfp.co.uk HOME CONTENTS

Page 109: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Floating Roof TanksThe petrochemical industry requires that tank fires caused by the ignition of combustible gases are extinguished in a short time frame. A rim seal Alarmline detection system provides a fast extinguishant response.

Cable TunnelsHigh power cable installations at power stations, airport terminals, railway stations and any installations requiring substantial power requirements can be protected by Alarmline sensor cables. Alarmline cable is suitable for use in harsh environments.

ConveyorsOverheating bearings on conveyor support rollers can be a common cause of conveyor belt fires. Alarmline systems can detect these overheat conditions. Additional protection can be provided above and below the conveyor belt against spillage and the transportation of ignited material.

Bulk StorageAlarmline “In rack“ protection at multiple levels ensures rapid fire detection. As part of a pre action sprinkler system, an advance warning of imminent sprinkler operation may avoid unnecessary water damage to stored goods.

Car ParksThe combustible materials used in the manufacture of modern passenger vehicles results in fires that burn more intensely and generate higher temperatures than ever before. That’s why early detection of fire conditions is essential in enclosed over and underground car parks. Alarmline installed at the ceiling achieves this by detecting significant rises in temperature not just at localised “hot spots” but over the entire length of cable.

EscalatorsAlarmline system provides for the total protection of escalators with coverage provided at all potential fire risk areas i.e. drive motors , return roller bearings dust collection trays and truss rollers. Alarmline can be used to give fire alarm indication and also to initiate a sprinkler system.

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 108 109ZOOM PRINT EXITPAGE 109/120 www.kfp.co.uk HOME CONTENTS

Page 110: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

ALARMLINE LINEAR HEAT DETECTION

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 110 111

ALARMLINEAnalogueAlarmline Analogue cable senses temperature variations by continuously monitoring the resistance of the specially doped Negative Temperature Coefficient (NTC) polymeric insulation. A change in temperature produces a relative change in resistance which is monitored by a dedicated Alarmline controller.

Suitable for Hazardous Area applications when used with approved Zener Barriers.

ALARMLINE LHD4 CONTROLLER

53836-K253 LHD4 Controller, conventional zone 2 wire connection (non CE)

53836-K256 LHD4 Controller, fire and fault relay outputs (fault relay energised) (No CE) FM approved

This unit is used to monitor alarmline analogue cable and actuate an alarm signal at a pre determined level. The integrating effect of Alarmline sensor cable enables it to detect either a hot spot or a lower level of temperature increase along its total length.

Technical specification Enclosure Polycarbonate, IP 54 rated, 130W X 178H X 99 D Colour RAL 7035, Weight 0.81KgSupply Voltage 8 to 30 VdcQuiescent Current Consumption 60 to 180 µA depending on alarm trip settingFire Alarm Current Consumption 15 to 70 mA preset by means of internal resistorFault Alarm Current Consumption 180 µA maximumMaximum length of detection cable 1000m

Series 4LHD with Fire and Fault RelaysQuiescent Current Consumption 20 mAFire Alarm Current Consumption 85 mAFault Alarm Current Consumption 16 mA

IndicatorsFire Alarm Front panel mounted continuous Red Fault Alarm Front panel mounted flashing yellow LEDOperating Temperature Range -25°C to + 52°C

53836-K255 LHD4 Controller, fire and fault relay outputs (fault relay energised)

53836-K257 LHD4 fire and fault relay outputs (fault relay de-energised)

53836-K254 LHD4 Controller, conventional zone 2 wire connection

ZOOM PRINT EXITPAGE 110/120 www.kfp.co.uk HOME CONTENTS

Page 111: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

LWM1 ALARMLINE CONTROLLER(EN54 Pt5 approved)

53836-K248 LWM1 Alarmline controller

ALARMLINE ANALOGUE CABLE (FM APPROVED)

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 110 111

The LWM1 controller monitors alarmline analogue sensor cable combining both fixed temperature (Max–alarm) and rate of rise temperature (Diff-alarm) detection.

The control unit reports temperature differences by the permanent supervision of the resistance of the sensor cable. The Max – alarm is triggered if the adjustable static alarm temperature of the sensor cable is reached or exceeded. The rate of rise alarm (Dif-alarm) is triggered by the adjustable integration of time and temperature change.

Technical specification Enclosure ABS IP 65 rated 200W x 120H x 80D Colour RAL 7035 Weight 0.55KgSupply Voltage 10 to 30 VdcQuiescent Current Consumption 25 mADiff-alarm or Max-Alarm Current Consumption 25 mAFault alarm Current Consumption 15 mA Operating Temperature Range -20°C to + 50°C

Approved to EN54 PART 5 when used with cable part numbers K82017, K82021 and K98166 (max 300m).

Recommended for environments ranging from clean and dry to moderate dust and moisture.Not for external use or for installations where corrosive agents or damage to cable may occur.

Ext. Dia. 3.25mmWeight 3.2 Kg (200m)

Typical installationsCable Trays Ceiling and Floor Voids Electrical Switch Gear Service Ducts Tunnels

K82017 Alarmline, blue PVC outer sheath

K82021 Alarmline black nylon outer sheath

ALARMLINE ANALOGUE CABLE (FM APPROVED)

Recommended for hostile environments, Petrochemical, Cold Storage, and general external use.Can also be used in areas where more rigidity or discreet installations are required.

Ext. Dia. 4.25mmWeight 4.3 Kg (200m)

Typical installationsFloating Roof Tanks Cold Stores Car Parks Paint Spray Booths Silos and DriersAreas subject to chemical contamination.

ZOOM PRINT EXITPAGE 111/120 www.kfp.co.uk HOME CONTENTS

Page 112: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

ALARMLINE LINEAR HEAT DETECTION

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 112 113

ALARMLINE ANALOGUE CABLE (FM APPROVED)

Recommended for areas which have a high risk of friction or mechanical damage.

Ext. Dia. 4.25mmWeight 8.3 Kg (200m)

Typical installationsConveyors Travelators Escalators Elevators Thatched Roofs

K82078 Alarmline PVC and Bronze Braided outer sheath

K98166 Alarmline Nylon, Stainless Steel Braided Sensor

ALARMLINE ANALOGUE CABLE (FM APPROVED)

Recommended for areas where a high level of chemical and mechanical damage is likely.

Ext. Dia. 5.5mmWeight 10 Kg (200m)

Typical installations

Mines Offshore Installations

ALARMLINEDigital Cable(ALL FM APPROVED)

Alarmline Digital is a twin conductor switching cable with temperature sensitive insulation, protected by a special braid, PVC or high temperature, chemical resistant polymer outer sheath to meet specific application requirements. Alarmline Digital cable operates by melting of the internal insulation between the conductors, at a predetermined temperature. This results in a short circuit which provides a fire alarm signal. Fire and fault conditions are provided by continuously monitoring for a short circuit (Fire) or open circuit (Fault) state by the fire alarm panel.

Suitable for Hazardous Area applications when used with approved Zener Barriers or Galvanic Isolators.

Conductors Tinned copper-covered steelMax conductor resistance 100 ohms per km at 20°CVoltage rating 110 VdcPulling force 50N maxBend radius 50mm minimum

ZOOM PRINT EXITPAGE 112/120 www.kfp.co.uk HOME CONTENTS

Page 113: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 112 113

63-70°C ALARM (67°C NOMINAL) CABLE TYPE H8040 MAX AMBIENT TEMPERATURE 45°C

Min operating temperature -40°CDiameter 3.7mmWeight 16.8 Kg/Km

Polythene braid outer covering red/green identification, suitable for internal use. In areas where corrosive agents are not present.

D5387-068

63-70°C ALARM (67°C NOMINAL) CABLE TYPE H8040N MAX AMBIENT TEMPERATURE 45°C

Min operating temperature -40°CDiameter 3.35mmWeight 15.85 Kg/Km

Nylon outer sheath, suitable for external use or in areas where corrosive agents could be present.

D5387-368

79-95°C ALARM (67°C NOMINAL) CABLE TYPE H8045 MAX AMBIENT TEMPERATURE 45°C

Min operating temperature -40°CDiameter 3.1mmWeight 16.8 Kg/Km

Polythene braid outer sheath, red/black identification, suitable for internal use in areas where corrosive agents are not present.

D5387-085

79-95°C ALARM (67°C NOMINAL) CABLE TYPE H8040N MAX AMBIENT TEMPERATURE 45°C

Min operating temperature -40°CDiameter 3.35mmWeight 15.85 Kg/Km

Nylon outer sheath, suitable for external use and in areas where corrosive agents could be present.

D5387-385

101-108°C ALARM (105°C NOMINAL) CABLE TYPE H8028 MAX AMBIENT TEMPERATURE 70°C

Min operating temperature -30°CDiameter 4.25mmWeight 22.7 Kg/Km

Black PVC covering suitable for internal and external applications. Excluding areas contaminated by chemical agents which could affect the PVC outer sheath.

D5387-105

177-189°C ALARM (183°C NOMINAL) CABLE TYPE H8069 MAX AMBIENT TEMPERATURE 105°C

Min operating temperature -40°CDiameter 4.35mmWeight 18.85 Kg/Km

Red PVC covering suitable for internal and external applications. Not suitable for areas with long exposure to direct sunlight.

D5387-174

ZOOM PRINT EXITPAGE 113/120 www.kfp.co.uk HOME CONTENTS

Page 114: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

ALARMLINE LINEAR HEAT DETECTION

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 114 115

229-251°C ALARM (240°C NOMINAL) CABLE TYPE H9650 MAX AMBIENT TEMPERATURE 200°C

Min operating temperature -50°CDiameter 3.5mmWeight 21.8 Kg/Km

Fluropolymer covering suitable for external applications where high ambient temperatures are expected or where protection against chemical agents is required. Suitable for use in direct sunlight.

D5387-227

ALARMLINEFixing Accessories

EDGE CLIP

Edge clips are used as a quick and easy way to install Alarmline cable, used on girders, steel sections, floating roof storage tank rim seals and foam dams, etc. Clips are generally installed at 1 metre spacing.

Material: Heat treated spring steel with a multi layer zinc phosphate coating

B6782-003 Suitable for steel thickness 2–3mm

B6782-024 Suitable for steel thickness 3–8mm

B6782-025 Suitable for steel thickness 8–14mm

B6782-026 Suitable for steel thickness 14–20mm

B6782-008 Neoprene Sleeve

B6782-121 Cable Tie

Also shown in picture

Kidde offer a wide range of mounting accessories to enable ease of installation for Alarmline Analogue and Alarmline digital cables.

The fixings available allow the Alarmline cables to be attached to walls, cable trays, girders, pipework etc. to suit the majority of applications.

B6782-195 Suitable for steel thickness 3-8mm Stainless Steel version

ZOOM PRINT EXITPAGE 114/120 www.kfp.co.uk HOME CONTENTS

Page 115: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 114 115

T CLIP

“T” Clip is used to fix all Alarmline cables (except K98166 Stainless Steel) to surfaces that are suitable for drilling i.e. wood and concrete. Recommended spacing 1 per metre.

Material: Plastic Upper Temperature Limit + 85°C Lower Temperature Limit - 50°C Material Degrades at + 120°C

B6782-004 T clip

V CLIP

“V” Clip specifically designed to fit Admiralty standard cable tray at 1 metre spacing.

Material: Spring Steel with spray coated finish. Clip comes complete with protective neoprene pad. Recommended spacing 1 per metre.

B6782-023 V clip

NEOPRENE SLEEVE

40 mm split sleeve is used to protect Alarmline cables from being crushed or damaged when attached to fixing clips.The sleeve also acts as an insulator to prevent the transfer of heat through metal fixing clips. Fire resistant.

B6782-008 Neoprene sleeve

CABLE TIE

U.V. Stabilised cable tie 100mm long x 2.5 mm wide.Used to secure Alarmline cable to fixing clips where necessary.

B6782-121 Cable tie

PIPE CLIP

Stainless Steel 304

Pipe clip is universal and will fit any diameter pipe (pipe strapping or cable tie required) Recommended spacing 1 per metre.

B6782-121 Cable tie

B6782-008 Neoprene sleeve

B6782-005 Pipe clip

B6782-121 Cable tie

B6782-121 Cable tie (Required if V clip is inverted)

Also shown in picture

Also shown in picture

ZOOM PRINT EXITPAGE 115/120 www.kfp.co.uk HOME CONTENTS

Page 116: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

ALARMLINE LINEAR HEAT DETECTION

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 116 117

CHANNEL BRACKET

Channel Bracket is designed to secure Alarmline cable onto horizontal metal surfaces where there is no return edge available to fix a bracket or clip. Mainly used on fixed Roof Storage Tanks. It is secured using a two part chemical anchoring system.

Material Stainless Steel 304

B6782-142 Channel bracket

CHANNEL BRACKET CHEMICAL ANCHORING SYSTEM

Used for fixing Channel Brackets to Fixed Roof Tanks

380ml Cartridge containing two part chemical anchoring system, based on a polyester resin. Each cartridge is suitable for 25 applications in single continuous operation. Each cartridge is supplied with one self mixing nozzle. Additional nozzles are available.

This product has a 12 month shelf life. COSHH statement is available.

A6782-201 Combined Resin and Hardener

L BRACKET C/W STRAIN RELIEF BUSH

“L” Bracket designed to support Alarmline cable above risk area i.e. Top run of cable tray. Recommended spacing 1 per metre.

Material Stainless Steel 304 Dimensions 150 mm x 20 mm x 20 mm

B6782-154 L bracket c/w strain relief bush

DISTANCE PIECE

Distance Piece can be used with edge brackets to extend the positioning of Alarmline cable. Spacing 1 per metre.

Material Mild Steel Zinc PlatedDimensions 200 mm x 20mm

B6782-120 Distance piece

B6782-008 Neoprene sleeve

B6782-143 Replacement Nozzle

B6782-008 Neoprene Sleeve

B6782-121 Cable tie

B6782-121 Cable tie

B6782-144 Heavy Duty Applicator GunAlso shown in picture

Also shown in picture

ZOOM PRINT EXITPAGE 116/120 www.kfp.co.uk HOME CONTENTS

Page 117: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 116 117

RETRACTABLE CABLES

Retractable cables are designed to provide electrical connection from tank roof to tank top on floating roof tanks, reducing the risk of cable being caught and snapped during the normal rising and falling movement of the tank roof.

Number of cores 4Core Colours 1 Blue 2 Brown 3 Black 4 YellowCore Size 0.75 mm 2Core Insulation Hytrel

(Used with Cable Collector B6782-032)

B6782-036 Retractable cable 10m

L BRACKET

“L” Bracket designed to fit with edge clip around floating roof storage tanks. The brackets are fixed to the foam dam using an edge clip. Spacing 1 per metre Used where the foam dam plate is vertical or has a 90 degree return edge.

Material Stainless Steel 304

B6782-194 L bracket

B6782-037 Retractable cable 11mB6782-008 Neoprene Sleeve

B6782-121 Cable tie

B6782-XXX Edge clip (xxx – denotes web thickness)35100-K254 M6 x 15mm Hex Bolt Stainless Steel35100-K253 M6 Full Nut Stainless Steel21176-K007 M6 Flat Washer Stainless Steel

B6782-038 Retractable cable 12m

B6782-039 Retractable cable 13m

B6782-040 Retractable cable 14m

B6782-030 Retractable cable 15m

B6782-041 Retractable cable 16m

B6782-042 Retractable cable 17m

B6782-043 Retractable cable 18m

B6782-044 Retractable cable 19m

B6782-045 Retractable cable 20m

B6782-046 Retractable cable 21m

B6782-047 Retractable cable 22m

B6782-048 Retractable cable 23m

B6782-049 Retractable cable 24m

B6782-050 Retractable cable 25m

B6782-170 Retractable cable 30m

Inner Sheath PolyurethaneOuter Sheath HytrelCable OD 10 mmCoil OD 230 mm Nom.Tails 1500 mm & 5000 mm

Also shown in picture

ZOOM PRINT EXITPAGE 117/120 www.kfp.co.uk HOME CONTENTS

Page 118: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

ALARMLINE LINEAR HEAT DETECTION

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 118 119

AUTOMATIC CABLE REELER

53836-K241 Automatic Cable Reeler with EX Polycarbonate Junction Box EX 112G EExe 11 PTB 01 ATEX 1014u

CABLE COLLECTOR

Designed to be fixed to a floating roof for collecting the retractable cables. The cable collector rises and falls with the movement of the roof, uncoiling the cable when the roof lowers, and collecting the cable when the roof rises. The collector is supplied with drainage holes.

Material: Stainless Steel 304

B6782-032 Cable collector

53836-K247 Automatic Cable Reeler with EX Stainless Steel Junction Box

B6782-000 Retractable Cable (select cable length)

B6782-189 FLP Junction Box for Tank Top

B6782-190 FLP Junction Box for Tank Roof

Cable:4 conductors 1mmFlame retardantExternal coating: SantopreneResistant to chemical agentsOperating temperature: -40 to + 70°CResistance: 19.5 ohm /kmCapacitance spec: 80nF/kmInductance spec: 0.9mH/kmInsulation resistance: 100 Mohm/km

2

The Kidde Automatic Reeler is an alternative system to using the retractable cable and cable collector. It is installed on the top rim of the tank body. The cable is connected to a junction box (part number B6782-190) located on the tank roof. The automatic cable reeler follows the movement of the roof, uncoiling the cable as the roof lowers, and winding the cable in when the roof rises. Maximum drop 25 metres

If the area that the equipment is installed in is classed as Hazardous, electrical connection must be via suitable safety barriers.

Materials:Box: Stainless steel 304Internal spring: Carbon steelInternal devices: ABS/ Fibre glass

ZOOM PRINT EXITPAGE 118/120 www.kfp.co.uk HOME CONTENTS

Page 119: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Tel: +44 (0)1844 265003 E-mail: [email protected] Web: www.kfp.co.uk 118 119

JUNCTION BOX TANK ROOF

EExe junction box to be mounted on the roof of the floating roof storage tank. Allows electrical connection between retractable cable and Alarmline detection cable..

Technical Data.• Increased safety EExe• Suitable for use in Zone 1, Zone 2, Zone 21 and Zone 22• Ingress protection to IP66• Size: 120W x 120H x 73.5D• 4 x 7mm dia fixing holes at 102mm sq CRS• Weight: 0.8kg• Operating temperature range: -60°c to +75°c• Temperature class and ambient: T6 40°c• Material: GRP, Natural black finish• Flame Retardant to IEC 92.1 Clause 2.38• Terminals 4 x 2.5mm. 1 x Earth 4mm• Cable glands Ex d IP66 3 x M20 Brass

B6782-190 Junction Box Tank Roof

JUNCTION BOX TANK TOP

EExe junction box to be mounted at the top of the floating roof storage tank. Allows electrical connection from site cabling to retractable cable.

Technical Data.• Increased safety EExe• Suitable for use in Zone 1, Zone 2, Zone 21 and Zone 22• Ingress protection to IP66• Size: 120W x 120H x 73.5D• 4 x 7mm dia fixing holes at 102mm sq CRS• Weight: 0.8kg• Operating temperature range: -60°c to +75°c• Temperature class and ambient: T6 40°c• Material: GRP, Natural black finish• Flame Retardant to IEC 92.1 Clause 2.38• Supplied with Steel Earth Continuity Plate• Terminals 6 x 2.5mm. 1 x Earth 4mm• Cable glands Ex d IP66 1 x M25 Brass 1 x M20 Brass

B6782-189 Junction Box Tank top

ZOOM PRINT EXITPAGE 119/120 www.kfp.co.uk HOME CONTENTS

Page 120: PRODUCT CATALOGUE - Pacific Sensepacificsense.com.hk/products/kidde/Elec_catalogue.pdf · PRODUCT CATALOGUE A UTC Fire ... Detector types 38 Discovery Intelligent Fire Detection 40

Kidde Fire ProtectionThame Park RoadThameOxfordshireOX9 3RTUnited Kingdom

Tel: +44 1844 265 003Fax: +44 1844 265 156Email: [email protected] Web: www.kfp.co.uk

A UTC Fire & Security Company

Designed and produced by Right Angle • www.rightangle.co.uk

EUROPE

Kidde DenmarkIndustriholmen 17-19DK-2650 HvidovreDENMARK

Tel: +45 36 86 9600Fax: +45 36 86 9611Email: [email protected]: www.ginge-kerr.dk

Kidde Eesti A/SLaki 11BTallinnESTONIA

Tel: +372 651 7010Fax: +372 651 7011Email: [email protected]: www.kidde.ee

Kidde FinlandBox 46Tiilenpolttajankuja 6SF 01720 VantaaFINLAND

Tel : +358 96 158 701Fax : +358 96 158 7285Email : [email protected] : www.kidde.fi

Kidde Brand-und Explosionsschutz GmbHSteinerne Furt 7886167 AugsburgGERMANY

Tel: +49 8217 48295 22Fax: +49 8217 48295 10Email: [email protected]: www.kidde.de

Kidde LietuvaLakunu Str 30LT 09131 VilniusLITHUANIA

Tel : +370 5 26 30040Fax : +370 5 26 30031Email : [email protected] : www.kidde.lt

UFS Russia and CISLyusinovskaya str.36Bld 1, 10 floor115093MoscowRUSSIA

Tel: +7 495 937 1891Fax: +7 495 937 1890Email: [email protected]

Kidde Sweden ABBox 90120Virkesvagen 12120 21 StockholmSWEDEN

Tel: +46 08 615 9900Fax: +46 08 615 9999Email: [email protected]: www.kidde.se

ASIA PACIFIC

Kidde Australia Pty Ltd314 Boundary RoadDingley, VIC 3172AUSTRALIA

Tel: +61 (3) 9518 5588Fax: +61 (3) 9518 5577Email: [email protected]: www.kidde.com.au

Shanghai Kidde Fire Protection Trading Co LtdC, 2/F Sun Tong Infoport Plaza55 Hau Hai Road (West)Shanghai 200030CHINA

Tel: +86 21 616 11 800Fax: +86 21 616 11 808Email: [email protected]: www.utcfireandsecurity.com

Kidde ChinaRoom 304, 3/F Guardforce Centre3 Hok Yuen Street EastHung HomKowloonHONG KONG

Tel: +852 2195 3688Fax: +852 2370 8381Email: [email protected] [email protected]

Kidde India LimitedEL 205, TTC Industrial AreaMahape, Navi Mumbai400 710 – INDIA

Tel : +91 22 6780 3131Fax: +91 22 2761 8444Email: [email protected]: www.kiddeindia.com

Kidde Asia Pty Ltd70 Bendemeer RoadLuzerne #02-02SINGAPORE 339940

Tel: +65 642 47 970Email: [email protected]: www.kiddeasia.com

SOUTH AMERICA

Kidde Resmat ParschRua Parsch 755Distrito Industrial – 132800-000Vinhedo-SPBRASIL

Tel: +55 19 2101 8456Fax: +55 19 2101 8424Email: [email protected]: www.kidde.com.br

MIDDLE EAST

Kidde LimitedOffice 201, Bu Ameem Building 2KaramaDubaiPO Box 30791UNITED ARAB EMIRATES Tel: +00971 433 72498Fax: +00971 433 75088Email: [email protected]

“Kidde Fire Protection operates a continuous programme of product development. The right is therefore reserved to modify any specification without prior notice.”

© Kidde Fire Protection 6586/1 04.09

ZOOM PRINT EXITPAGE 120/120 www.kfp.co.uk HOME CONTENTS