ProduCt Catalogue - · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 -...

50
www.kabex.com.au Ph: 02 9675 7616 • IndustrIal Cables • Hazardous area equIPment • Cable termInatIon ProduCt Catalogue 2011 Ver 1.1

Transcript of ProduCt Catalogue - · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 -...

Page 1: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

www.kabex.com.au • Ph: 02 9675 7616

• IndustrIal Cables

• Hazardous area equIPment

• Cable termInatIon

ProduCt Catalogue

2011 Ver 1.1

Page 2: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

KabEx Australia is a leading company specializing

in the supply of cables, hazardous area equipment

and associated goods.

By bringing together the best of relationships with

both overseas factories and local suppliers KabEx

offers a complete range of cables with particular

emphasis on flexible power cables, instrumentation

cables, low and medium voltage cables.

We offer a custom manufacture service to meet

any specification of specialty cables with very

competitive pricing which includes fast lead times

and low minimum order quantities.

KabEx Australia is also the sole Australian importer

of OSCG cable glands and accessories for both

Hazardous & Industrial Area.

Our extensive experience includes exporting to

major projects throughout the Asia, Pacific and

Middle East regions. We also offer nationwide

coverage with particular strengths in servicing the

entire Eastern Seaboard of Australia and remote

areas.

All products supplied by KabEx meet our strict

quality criteria and are made to the highest

standard in ISO9001 certified factories.

Page 3: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

Instrumentation Cable 2 - 10

Overall Screened Pairs 3Ind & Overall Screened Pairs 4Overall Screened SWA Pairs 5Ind & Overall Screened SWA Pairs 6Overall Screened Triples 7Ind & Overall Screened Triples 8Overall Screened SWA Triples 9Ind & Overall Screened SWA Triples 10

Flexible Cables PVC 11 - 17

Clear Sheath Flexible EMC Cable 11XLPE Insulated, UV Stabalised, Flexible EMC Cable 12PVC Flexible Control Cable 14

Flexible Cables Rubber 18 - 23

Single Core 110Deg 3.3kV Flexible 18 Ozoflex Rubber 20

Hi Temperature 24 - 28

Halogen Free Single Core 125Deg Flexible 24Sinotherm High Temperature Cables 26

Siemens Speciality Cables 29

OSCG Hazardous & Industrial Area 30 - 39

OSGP Hazardous Area Enclosures 30OSNJA2F Hazardous Gland for Unarmoured Cables 31OSSP Hazardous Area Stopping Plug 32OSRA Hazardous Area Reducer 33OSAJ Hazardous Area Adaptor 34OSAE Hazardous Area Elbow 35OSNJ Industrial Metal Cable Gland 36OSNJ-CW Industrial Gland for SWA Cables 37OSPG PG Thread Cable Glands 38Earth Tags, Lock Nuts, Washers 39

Cable Termination Accessories 40 - 46

Stainless Steel Cable Tie 40Nylon Cable Tie 41Nylon Cable Gland, Slotted Duct 42Bootlace Ferruls 43Copper Lugs, Bellmouth Lugs, Crimp Links 44K Type Cable Markers 46

Contents

Page 4: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

2

APPLICATIONUsed in data processing and process control. Suitable for fixed installations in damp locations and open spaces. The electrostatic screen protects against outer interference fields.

DesIgNLSZH (Low Smoke Zero Halogen) Instrumentation cable consisting of bare copper conductors, black & white twisted pairs or black, white & red twisted triples with continuous number sequence.

Cables are manufactured strictly in accordance of UL as well as relevant Australian Standards. VOLTAge RATINgRated Voltage Max. 300V a.cNominal Voltage A.C/D.C 110/150VTest Voltage In process spark test – 4500V and AC withstand voltage test – 1500V

TeChNICAL DATA 0.5mm 1.5mmMaximum Capacitance Conductor to Conductor 145pF/m 200pF/m Conductor to Screen 240pF/m 300pF/mMaximum Conductor Resistance @ 20 C 38.4Ω/km 13.8Ω/kmInsulation Resistance @ 20 C 40MΩ/km 140MΩ/kmCross Talk Attentuation Between Pairs @ 1kHz 300Ω 150ΩInductance @ 1kHz 1.00mH/km 0.95mH/kmL/R Ratio @ 1kHz 13.7µH/Ω 36.5µH/Ω

OPeRATINg TemPeRATuReMinimum continuous operating temperature -25°CMaximum continuous operating temperature 75°CMaximum conductor operating temperature 90°CMinimum short circuit temperature 160°C (for 5 sec)

BeNDINg RADIIThe following minimum bending radius should be observed to ensure operating reliabilityunarmoured: 9 x cable outer diameter (during installation) 6 x cable outer diameter (after installation)

Armoured: 18 x cable outer diameter (during installation) 12 x cable outer diameter (after installation)

TeNsILe sTReNgThCable maximum pulling tension (approximate) is limited to 65-70 N/mm² of the total cross-sectional area of conductor.Example:3pairs 1.5 total cross sectional area 3x 2x1.5=9mm² 9mm² x 70Nmm² =630N (0.63kn)

For pulling by armour, the pulling tension should be limited to 130 N/mm² of the total cross-sectional of steel wire.

INSTRUMENTATION CABLE

Page 5: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

3

INSTRUMENTATION CABLEOverall Screened Cable LSZH

0.5mm²

Part No Pairs Conductor No/Dia (mm)

Insulation thickness

(mm)

Nom. Overall Diameter (mm)

Conductor Resistance @ 20c Ohm/km

Approximate weight (kg/km)

0.5MM1PR 1 7/0.30 0.4 5 38.4 28

0.5MM2PR 2 7/0.30 0.4 7.3 38.4 51

0.5MM3PR 3 7/0.30 0.4 8.1 38.4 71

0.5MM4PR 4 7/0.30 0.4 8.7 38.4 86

0.5MM6PR 6 7/0.30 0.4 10.5 38.4 124

0.5MM8PR 8 7/0.30 0.4 11.7 38.4 166

0.5MM10PR 10 7/0.30 0.4 13.9 38.4 210

0.5MM12PR 12 7/0.30 0.4 14.3 38.4 239

0.5MM16PR 16 7/0.30 0.4 16.3 38.4 317

0.5MM20PR 20 7/0.30 0.4 17.9 38.4 396

0.5MM24PR 24 7/0.30 0.4 20.5 38.4 477

0.5MM36PR 36 7/0.30 0.4 23.5 38.4 675

1.5mm²

Part No Pairs Conductor No/Dia (mm)

Insulation thickness

(mm)

Overall Diameter (mm)

Conductor Resistance @ 20c Ohm/km

Approximate weight (kg/km)

1.5MM1PR 1 7/0.50 0.4 6.1 13.8 53

1.5MM2PR 2 7/0.50 0.4 11 13.8 103

1.5MM3PR 3 7/0.50 0.4 12.2 13.8 145

1.5MM4PR 4 7/0.50 0.4 13 13.8 183

1.5MM6PR 6 7/0.50 0.4 14 13.8 266

1.5MM8PR 8 7/0.50 0.4 15.2 13.8 349

1.5MM10PR 10 7/0.50 0.4 18.2 13.8 430

1.5MM12PR 12 7/0.50 0.4 19 13.8 506

1.5MM16PR 16 7/0.50 0.4 21.3 13.8 658

1.5MM20PR 20 7/0.50 0.4 23.4 13.8 809

1.5MM24PR 24 7/0.50 0.4 27 13.8 974

1.5MM36PR 36 7/0.50 0.4 29.7 13.8 1403

Intrinsically safe version – add BLue to part number

Intrinsically safe version – add BLue to part number

CONsTRuCTION CONsIsTINg Of:Bare copper conductors to AS1125Flame retardant FR-V90 Insulation to UL style 1569Overall screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wireBlack outer sheath with flame retardant V90 LSZH UL style 2462 (Blue Intrinsically Safe option avail)

Page 6: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

4

INSTRUMENTATION CABLEIndividual & Overall Screened Cable LSZH

0.5mm²

Part No Pairs Conductor No/Dia (mm)

Insulation thickness

(mm)

Nom. Overall Diameter (mm)

Conductor Resistance @ 20c Ohm/km

Approximate weight (kg/km)

0.5MM2PRES 2 7/0.30 0.4 8.8 38.4 58

0.5MM4PRES 4 7/0.30 0.4 9.3 38.4 100

0.5MM6PRES 6 7/0.30 0.4 11.3 38.4 145

0.5MM8PRES 8 7/0.30 0.4 12.6 38.4 193

0.5MM10PRES 10 7/0.30 0.4 14.9 38.4 244

0.5MM12PRES 12 7/0.30 0.4 15.4 38.4 279

0.5MM16PRES 16 7/0.30 0.4 17.5 38.4 370

0.5MM20PRES 20 7/0.30 0.4 19.3 38.4 462

0.5MM24PRES 24 7/0.30 0.4 22.1 38.4 558

0.5MM36PRES 36 7/0.30 0.4 25.3 38.4 792

1.5mm²

Part No Pairs Conductor No/Dia (mm)

Insulation thickness

(mm)

Nom. Overall Diameter (mm)

Conductor Resistance @ 20c Ohm/km

Approximate weight (kg/km)

1.5MM2PRES 2 7/0.50 0.4 11.1 13.8 113

1.5MM4PRES 4 7/0.50 0.4 12.1 13.8 199

1.5MM6PRES 6 7/0.50 0.4 14.6 13.8 290

1.5MM8PRES 8 7/0.50 0.4 16.2 13.8 381

1.5MM10PRES 10 7/0.50 0.4 19 13.8 470

1.5MM12PRES 12 7/0.50 0.4 21.1 13.8 570

1.5MM16PRES 16 7/0.50 0.4 22.2 13.8 717

1.5MM20PRES 20 7/0.50 0.4 24.2 13.8 884

1.5MM24PRES 24 7/0.50 0.4 27.8 13.8 1064

1.5MM36PRES 36 7/0.50 0.4 31.9 13.8 1535

Intrinsically safe version – add BLue to part number

Intrinsically safe version – add BLue to part number

CONsTRuCTION CONsIsTINg Of:Bare copper conductors to AS1125Flame retardant FR-V90 Insulation to UL style 1569Individual screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wireOverall screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wireBlack outer sheath with flame retardant V90 LSZH UL style 2462 (Blue Intrinsically Safe option avail)

Page 7: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

5

INSTRUMENTATION CABLEOverall Screened SWA Cable LSZH

0.5mm²

Part No Pairs Conductor No/Dia

(mm)

Insulation thickness

(mm)

Overall diameter

over bedding

(mm)

steel wire Amour

diameter (mm)

Overall diameter

over armour

(mm)

Overall Diameter

(mm)

Conductor Resistance @ 20c Ohm/km

Approximate weight (kg/

km)

0.5MM1PRSWA 1 7/0.30 0.4 5.6 0.9 7.4 10.4 38.4 225

0.5MM2PRSWA 2 7/0.30 0.4 8.6 0.9 10.4 12.5 38.4 298

0.5MM4PRSWA 4 7/0.30 0.4 9.8 0.9 11.6 14.5 38.4 358

0.5MM6PRSWA 6 7/0.30 0.4 10.6 0.9 12.4 15.5 38.4 440

0.5MM8PRSWA 8 7/0.30 0.4 11.4 0.9 13.2 16.7 38.4 507

0.5MM10PRSWA 10 7/0.30 0.4 13.3 0.9 15.1 18.7 38.4 592

0.5MM12PRSWA 12 7/0.30 0.4 13.7 0.9 15.5 19.1 38.4 632

0.5MM16PRSWA 16 7/0.30 0.4 15.4 0.9 17.2 21.3 38.4 763

0.5MM20PRSWA 20 7/0.30 0.4 16.6 1.25 19.1 23.2 38.4 1006

0.5MM24PRSWA 24 7/0.30 0.4 18.9 1.25 21.4 25.6 38.4 1150

0.5MM36PRSWA 36 7/0.30 0.4 21.8 1.25 24.3 28.8 38.4 1449

1.5mm²

Part No Pairs Conductor No/Dia

(mm)

Insulation thickness

(mm)

Overall diameter

over bedding

(mm)

steel wire Amour

diameter (mm)

Overall diameter

over armour

(mm)

Overall Diameter

(mm)

Conductor Resistance @ 20c Ohm/km

Approximate weight (kg/

km)

1.5MM1PRSWA 1 7/0.50 0.4 6.7 0.9 8.5 11.5 13.8 278

1.5MM2PRSWA 2 7/0.50 0.4 10.4 0.9 12.2 15.3 13.8 390

1.5MM4PRSWA 4 7/0.50 0.4 11.9 0.9 13.7 17.8 13.8 498

1.5MM6PRSWA 6 7/0.50 0.4 13.2 0.9 15 18.3 13.8 651

1.5MM8PRSWA 8 7/0.50 0.4 14.2 0.9 16 19.2 13.8 749

1.5MM10PRSWA 10 7/0.50 0.4 16.7 1.25 19.2 22.5 13.8 1043

1.5MM12PRSWA 12 7/0.50 0.4 17.3 1.25 19.8 23.8 13.8 1150

1.5MM16PRSWA 16 7/0.50 0.4 19.4 1.25 21.9 26 13.8 1370

1.5MM20PRSWA 20 7/0.50 0.4 21.3 1.25 23.8 28.1 13.8 1591

1.5MM24PRSWA 24 7/0.50 0.4 24.3 1.6 26.8 32.1 13.8 1856

1.5MM36PRSWA 36 7/0.50 0.4 27.9 1.6 31.1 35 13.8 2645

Intrinsically safe version – add BLue to part number

Intrinsically safe version – add BLue to part number

CONsTRuCTION CONsIsTINg Of:Bare copper conductors to AS1125Flame retardant FR-V90 Insulation to UL style 1569Overall screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wireBlack flame retardant FR-V90 inner sheath to UL style 2464Steel wire armourBlack outer sheath with flame retardant V90 LSZH UL style 2462 (Blue Intrinsically Safe option avail)

Page 8: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

6

0.5mm²

Part No. Pairs Conductor No/Dia

(mm)

Insulation thickness

(mm)

Overall diameter

over bedding

(mm)

steel wire Amour

diameter (mm)

Overall diameter

over armour

(mm)

Overall Diameter

(mm)

Conductor Resistance @ 20c Ohm/km

Approximate weight (kg/

km)

0.5MM2PRSWAES 2 7/0.30 0.4 9.2 0.9 11 14 38.4 318

0.5MM4PRSWAES 4 7/0.30 0.4 9.9 0.9 11.7 14.8 38.4 387

0.5MM6PRSWAES 6 7/0.30 0.4 11.3 0.9 13.1 16.3 38.4 480

0.5MM8PRSWAES 8 7/0.30 0.4 12.2 0.9 14 17.6 38.4 555

0.5MM10PRSWAES 10 7/0.30 0.4 14.3 0.9 16.1 19.7 38.4 651

0.5MM12PRSWAES 12 7/0.30 0.4 14.8 0.9 16.6 20.2 38.4 699

0.5MM16PRSWAES 16 7/0.30 0.4 16.6 0.9 19.1 22.8 38.4 995

0.5MM20PRSWAES 20 7/0.30 0.4 17.9 1.25 20.4 24.6 38.4 1113

0.5MM24PRSWAES 24 7/0.30 0.4 20.5 1.25 23 27.2 38.4 1277

0.5MM36PRSWAES 36 7/0.30 0.4 23.6 1.25 26.1 30.6 38.4 1622

1.5mm²

Part No. Pairs Conductor No/Dia

(mm)

Insulation thickness

(mm)

Overall diameter

over bedding

(mm)

steel wire Amour

diameter (mm)

Overall diameter

over armour

(mm)

Overall Diameter

(mm)

Conductor Resistance @ 20c Ohm/km

Approximate weight (kg/

km)

1.5MM2PRSWAES 2 7/0.50 0.4 11 0.9 12.8 15.9 13.8 413

1.5MM4PRSWAES 4 7/0.50 0.4 12.1 0.9 13.9 17 13.8 532

1.5MM6PRSWAES 6 7/0.50 0.4 14.1 0.9 15.9 18.6 13.8 699

1.5MM8PRSWAES 8 7/0.50 0.4 15.2 0.9 17 20.2 13.8 805

1.5MM10PRSWAES 10 7/0.50 0.4 18.2 1.25 20.7 24 13.8 1136

1.5MM12PRSWAES 12 7/0.50 0.4 18.8 1.25 21.3 25.1 13.8 1252

1.5MM16PRSWAES 16 7/0.50 0.4 20.9 1.25 23.4 27.5 13.8 1477

1.5MM20PRSWAES 20 7/0.50 0.4 22.9 1.25 25.4 29.7 13.8 1718

1.5MM24PRSWAES 24 7/0.50 0.4 26.2 1.6 29.4 34 13.8 2236

1.5MM36PRSWAES 36 7/0.50 0.4 30.1 1.6 33.3 38.1 13.8 2864

INSTRUMENTATION CABLEIndividual & Overall Screened SWA Cable LSZH

Intrinsically safe version – add BLue to part number

Intrinsically safe version – add BLue to part number

CONsTRuCTION CONsIsTINg Of:Bare copper conductors to AS1125Flame retardant FR-V90 Insulation to UL style 1569Individual screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wireOverall screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wireBlack flame retardant FR-V90 inner sheath to UL style 2464Steel wire armourBlack outer sheath with flame retardant V90 LSZH UL style 2462 (Blue Intrinsically Safe option avail)

Page 9: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

7

0.5mm²

Part No. Pairs Conductor No/Dia

(mm)

Insulation thickness

(mm)

Overall diameter

over bedding

(mm)

steel wire Amour

diameter (mm)

Overall diameter

over armour

(mm)

Overall Diameter

(mm)

Conductor Resistance @ 20c Ohm/km

Approximate weight (kg/

km)

0.5MM2PRSWAES 2 7/0.30 0.4 9.2 0.9 11 14 38.4 318

0.5MM4PRSWAES 4 7/0.30 0.4 9.9 0.9 11.7 14.8 38.4 387

0.5MM6PRSWAES 6 7/0.30 0.4 11.3 0.9 13.1 16.3 38.4 480

0.5MM8PRSWAES 8 7/0.30 0.4 12.2 0.9 14 17.6 38.4 555

0.5MM10PRSWAES 10 7/0.30 0.4 14.3 0.9 16.1 19.7 38.4 651

0.5MM12PRSWAES 12 7/0.30 0.4 14.8 0.9 16.6 20.2 38.4 699

0.5MM16PRSWAES 16 7/0.30 0.4 16.6 0.9 19.1 22.8 38.4 995

0.5MM20PRSWAES 20 7/0.30 0.4 17.9 1.25 20.4 24.6 38.4 1113

0.5MM24PRSWAES 24 7/0.30 0.4 20.5 1.25 23 27.2 38.4 1277

0.5MM36PRSWAES 36 7/0.30 0.4 23.6 1.25 26.1 30.6 38.4 1622

1.5mm²

Part No. Pairs Conductor No/Dia

(mm)

Insulation thickness

(mm)

Overall diameter

over bedding

(mm)

steel wire Amour

diameter (mm)

Overall diameter

over armour

(mm)

Overall Diameter

(mm)

Conductor Resistance @ 20c Ohm/km

Approximate weight (kg/

km)

1.5MM2PRSWAES 2 7/0.50 0.4 11 0.9 12.8 15.9 13.8 413

1.5MM4PRSWAES 4 7/0.50 0.4 12.1 0.9 13.9 17 13.8 532

1.5MM6PRSWAES 6 7/0.50 0.4 14.1 0.9 15.9 18.6 13.8 699

1.5MM8PRSWAES 8 7/0.50 0.4 15.2 0.9 17 20.2 13.8 805

1.5MM10PRSWAES 10 7/0.50 0.4 18.2 1.25 20.7 24 13.8 1136

1.5MM12PRSWAES 12 7/0.50 0.4 18.8 1.25 21.3 25.1 13.8 1252

1.5MM16PRSWAES 16 7/0.50 0.4 20.9 1.25 23.4 27.5 13.8 1477

1.5MM20PRSWAES 20 7/0.50 0.4 22.9 1.25 25.4 29.7 13.8 1718

1.5MM24PRSWAES 24 7/0.50 0.4 26.2 1.6 29.4 34 13.8 2236

1.5MM36PRSWAES 36 7/0.50 0.4 30.1 1.6 33.3 38.1 13.8 2864

INSTRUMENTATION CABLEOverall Screened Triad Cable LSZH

0.5mm²

Part No Triples Conductor No/Dia (mm)

Insulation thickness

(mm)

Nom. Overall Diameter (mm)

Conductor Resistance @ 20c Ohm/km

Approximate weight (kg/km)

0.5MM1TR 1 7/0.30 0.4 5.2 38.4 36

0.5MM2TR 2 7/0.30 0.4 7.8 38.4 70

0.5MM3TR 3 7/0.30 0.4 8.9 38.4 84

0.5MM4TR 4 7/0.30 0.4 9.2 38.4 120

0.5MM6TR 6 7/0.30 0.4 11.3 38.4 179

0.5MM8TR 8 7/0.30 0.4 12.2 38.4 225

0.5MM10TR 10 7/0.30 0.4 14.6 38.4 290

0.5MM12TR 12 7/0.30 0.4 15.5 38.4 348

0.5MM16TR 16 7/0.30 0.4 17.1 38.4 442

0.5MM20TR 20 7/0.30 0.4 18.6 38.4 543

0.5MM24TR 24 7/0.30 0.4 21.3 38.4 653

0.5MM36TR 36 7/0.30 0.4 24.4 38.4 936

1.5mm²

Part No Triples Conductor No/Dia (mm)

Insulation thickness

(mm)

Nom. Overall Diameter (mm)

Conductor Resistance @ 20c Ohm/km

Approximate weight (kg/km)

1.5MM1TR 1 7/0.50 0.4 6.5 13.8 67

1.5MM2TR 2 7/0.50 0.4 10 13.8 135

1.5MM3TR 3 7/0.50 0.4 10.9 13.8 201

1.5MM4TR 4 7/0.50 0.4 11.8 13.8 237

1.5MM6TR 6 7/0.50 0.4 14.5 13.8 352

1.5MM8TR 8 7/0.50 0.4 16 13.8 463

1.5MM10TR 10 7/0.50 0.4 19.1 13.8 589

1.5MM12TR 12 7/0.50 0.4 19.7 13.8 683

1.5MM16TR 16 7/0.50 0.4 22.5 13.8 946

1.5MM20TR 20 7/0.50 0.4 24.3 13.8 1153

1.5MM24TR 24 7/0.50 0.4 27.7 13.8 1374

1.5MM36TR 36 7/0.50 0.4 32 13.8 2014

Intrinsically safe version – add BLue to part number

Intrinsically safe version – add BLue to part number

CONsTRuCTION CONsIsTINg Of:Bare copper conductors to AS1125Flame retardant FR-V90 Insulation to UL style 1569Overall screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wireBlack outer sheath with flame retardant V90 LSZH UL style 2462 (Blue Intrinsically Safe option avail)

Page 10: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

8

INSTRUMENTATION CABLEIndividual & Overall Screened Triad Cable LSZH

0.5mm²

Part No Triples Conductor No/Dia (mm)

Insulation thickness

(mm)

Nom. Overall Diameter (mm)

Conductor Resistance @ 20c Ohm/km

Approximate weight (kg/km)

0.5MM2TRES 2 7/0.30 0.4 8.3 38.4 78

0.5MM3TRES 3 7/0.30 0.4 8.8 38.4 103

0.5MM4TRES 4 7/0.30 0.4 9.8 38.4 135

0.5MM6TRES 6 7/0.30 0.4 12.1 38.4 201

0.5MM8TRES 8 7/0.30 0.4 13.3 38.4 259

0.5MM10TRES 10 7/0.30 0.4 15.7 38.4 326

0.5MM12TRES 12 7/0.30 0.4 16.2 38.4 377

0.5MM16TRES 16 7/0.30 0.4 18.3 38.4 498

0.5MM20TRES 20 7/0.30 0.4 19.3 38.4 599

0.5MM24TRES 24 7/0.30 0.4 23.1 38.4 748

0.5MM36TRES 36 7/0.30 0.4 26.3 38.4 1058

1.5mm²

Part No Triples Conductor No/Dia (mm)

Insulation thickness

(mm)

Nom. Overall Diameter (mm)

Conductor Resistance @ 20c Ohm/km

Approximate weight (kg/km)

1.5MM2TRES 2 7/0.50 0.4 10.9 13.8 152

1.5MM3TRES 3 7/0.50 0.4 11.8 13.8 212

1.5MM4TRES 4 7/0.50 0.4 12.9 13.8 269

1.5MM6TRES 6 7/0.50 0.4 15.8 13.8 399

1.5MM8TRES 8 7/0.50 0.4 17.5 13.8 525

1.5MM10TRES 10 7/0.50 0.4 20.9 13.8 668

1.5MM12TRES 12 7/0.50 0.4 21.5 13.8 776

1.5MM16TRES 16 7/0.50 0.4 24.1 13.8 1011

1.5MM20TRES 20 7/0.50 0.4 26 13.8 1233

1.5MM24TRES 24 7/0.50 0.4 29.7 13.8 1470

1.5MM36TRES 36 7/0.50 0.4 34.4 13.8 2154

Intrinsically safe version – add BLue to part number

Intrinsically safe version – add BLue to part number

CONsTRuCTION CONsIsTINg Of:Bare copper conductors to AS1125Flame retardant FR-V90 Insulation to UL style 1569Individual screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wireOverall screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wireBlack outer sheath with flame retardant V90 LSZH UL style 2462 (Blue Intrinsically Safe option avail)

Page 11: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

9

INSTRUMENTATION CABLEOverall Screened SWA Triad Cable LSZH

0.5mm²

Part No Triples Conductor No/Dia

(mm)

Insulation thickness

(mm)

Overall diameter

over bedding

(mm)

steel wire Amour

diameter (mm)

Overall diameter

over armour

(mm)

Overall Diameter

(mm)

Conductor Resistance @ 20c Ohm/km

Approximate weight (kg/

km)

0.5MM1TRSWA 1 7/0.30 0.4 5.9 0.9 7.7 10.6 38.4 239

0.5MM2TRSWA 2 7/0.30 0.4 8.1 0.9 9.9 12.8 38.4 329

0.5MM3TRSWA 3 7/0.30 0.4 8.5 0.9 10.3 13.2 38.4 356

0.5MM4TRSWA 4 7/0.30 0.4 9.3 0.9 10.5 14 38.4 399

0.5MM6TRSWA 6 7/0.30 0.4 11.4 0.9 11.1 16.3 38.4 517

0.5MM8TRSWA 8 7/0.30 0.4 12.3 0.9 13.2 17.2 38.4 585

0.5MM10TRSWA 10 7/0.30 0.4 14.3 0.9 14.1 19.4 38.4 697

0.5MM12TRSWA 12 7/0.30 0.4 14.8 0.9 16.1 20.3 38.4 770

0.5MM16TRSWA 16 7/0.30 0.4 16.4 0.9 18.2 21.9 38.4 903

0.5MM20TRSWA 20 7/0.30 0.4 17.7 0.9 19.5 23.2 38.4 1028

0.5MM24TRSWA 24 7/0.30 0.4 20.2 1.25 22.7 26.4 38.4 1363

0.5MM36TRSWA 36 7/0.30 0.4 23.5 1.25 26 30.1 38.4 1785

1.5mm²

Part No Triples Conductor No/Dia

(mm)

Insulation thickness

(mm)

Overall diameter

over bedding

(mm)

steel wire Amour

diameter (mm)

Overall diameter

over armour

(mm)

Overall Diameter

(mm)

Conductor Resistance @ 20c Ohm/km

Approximate weight (kg/

km)

1.5MM1TRSWA 1 7/0.50 0.4 7 0.9 8.8 11.7 13.8 303

1.5MM2TRSWA 2 7/0.50 0.4 9.9 0.9 11.7 14.6 13.8 437

1.5MM3TRSWA 3 7/0.50 0.4 10.9 0.9 12.8 15.8 13.8 520

1.5MM4TRSWA 4 7/0.50 0.4 11.9 0.9 13.7 16.8 13.8 609

1.5MM6TRSWA 6 7/0.50 0.4 14.2 0.9 16 19.3 13.8 784

1.5MM8TRSWA 8 7/0.50 0.4 15.3 0.9 17.1 20.8 13.8 935

1.5MM10TRSWA 10 7/0.50 0.4 18 1.25 20.5 24.2 13.8 1119

1.5MM12TRSWA 12 7/0.50 0.4 18.6 1.25 21.1 24.8 13.8 1401

1.5MM16TRSWA 16 7/0.50 0.4 20.7 1.25 23.2 27 13.8 1680

1.5MM20TRSWA 20 7/0.50 0.4 22.9 1.25 25.4 29.3 13.8 1986

1.5MM24TRSWA 24 7/0.50 0.4 26.4 1.6 29.6 33.7 13.8 2577

1.5MM36TRSWA 36 7/0.50 0.4 30.2 1.6 33.4 37.9 13.8 3379

Intrinsically safe version – add BLue to part number

Intrinsically safe version – add BLue to part number

CONsTRuCTION CONsIsTINg Of:Bare copper conductors to AS1125Flame retardant FR-V90 Insulation to UL style 1569Overall screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wireBlack flame retardant FR-V90 inner sheath to UL style 2464Steel wire armourBlack outer sheath with flame retardant V90 LSZH UL style 2462 (Blue Intrinsically Safe option avail)

Page 12: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

10

INSTRUMENTATION CABLEIndividual & Overall Screened SWA Triad Cable LSZH

0.5mm²

Part No Triples Conductor No/Dia

(mm)

Insulation thickness

(mm)

Overall diameter

over bedding

(mm)

steel wire Amour

diameter (mm)

Overall diameter

over armour

(mm)

Overall Diameter

(mm)

Conductor Resistance @ 20c Ohm/km

Approximate weight (kg/

km)

0.5MM2TRSWAES 2 7/0.30 0.4 8.6 0.9 10.4 13.3 38.4 344

0.5MM3TRSWAES 3 7/0.30 0.4 9.1 0.9 10.9 13.8 38.4 382

0.5MM4TRSWAES 4 7/0.30 0.4 9.9 0.9 11.7 14.6 38.4 429

0.5MM6TRSWAES 6 7/0.30 0.4 12 0.9 13.8 16.9 38.4 548

0.5MM8TRSWAES 8 7/0.30 0.4 13.2 0.9 15 18.1 38.4 635

0.5MM10TRSWAES 10 7/0.30 0.4 15.4 0.9 17.2 20.7 38.4 768

0.5MM12TRSWAES 12 7/0.30 0.4 15.9 0.9 17.7 21.9 38.4 830

0.5MM16TRSWAES 16 7/0.30 0.4 17.6 0.9 19.4 23.1 38.4 989

0.5MM20TRSWAES 20 7/0.30 0.4 19.1 0.9 20.9 25.7 38.4 1130

0.5MM24TRSWAES 24 7/0.30 0.4 21.8 1.25 24.3 29.5 38.4 1507

0.5MM36TRSWAES 36 7/0.30 0.4 25.4 1.25 27.9 34.9 38.4 1949

1.5mm²

Part No Triples Conductor No/Dia

(mm)

Insulation thickness

(mm)

Overall diameter

over bedding

(mm)

steel wire Amour

diameter (mm)

Overall diameter

over armour

(mm)

Overall Diameter

(mm)

Conductor Resistance @ 20c Ohm/km

Approximate weight (kg/

km)

1.5MM2TRSWAES 2 7/0.50 0.4 10.8 0.9 12.6 15.5 13.8 463

1.5MM3TRSWAES 3 7/0.50 0.4 11.7 0.9 13.5 16.6 13.8 551

1.5MM4TRSWAES 4 7/0.50 0.4 13 0.9 14.8 17.9 13.8 646

1.5MM6TRSWAES 6 7/0.50 0.4 15.5 0.9 17.3 20.6 13.8 834

1.5MM8TRSWAES 8 7/0.50 0.4 16.8 0.9 18.6 22.3 13.8 996

1.5MM10TRSWAES 10 7/0.50 0.4 19.8 0.9 21.6 25.3 13.8 1195

1.5MM12TRSWAES 12 7/0.50 0.4 20.4 1.25 22.9 26.6 13.8 1493

1.5MM16TRSWAES 16 7/0.50 0.4 22.8 1.25 25.3 29.2 13.8 1799

1.5MM20TRSWAES 20 7/0.50 0.4 25.1 1.25 27.6 31.5 13.8 2118

1.5MM24TRSWAES 24 7/0.50 0.4 29 1.6 32.3 36.3 13.8 2748

1.5MM36TRSWAES 36 7/0.50 0.4 33.3 1.6 38.3 42.8 13.8 4356

Intrinsically safe version – add BLue to part number

Intrinsically safe version – add BLue to part number

CONsTRuCTION CONsIsTINg Of:Bare copper conductors to AS1125Flame retardant FR-V90 Insulation to UL style 1569Individual screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wireOverall screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wireBlack flame retardant FR-V90 inner sheath to UL style 2464Steel wire armourBlack outer sheath with flame retardant V90 LSZH UL style 2462 (Blue Intrinsically Safe option avail)

Page 13: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

11

APPLICATIONSpecifically designed low capacitance screened cable for connection between AC variable speed drives and motors. Suitable for fixed installation and occasional freely flexing applications in dry damp and wet conditions.

DesIgNElectromagnetic compatibility (EMC) is the ability of electrical or electronic equipment to function normally in an environment without being affected by electromagnetic (EMI) and radio frequency interferences (RFI) or in turn disturbing the environment by transmitting EMI or RFI.

VOLTAge RATINgRated AC voltage: Uo/U = 0.6kV/1kV

PROTOFLEX EMC Clear sheath EMC cable

No. of

cores

x

Conductor

size

mm²

Part No. Approx. No.

of strands

x

max. strand

diameter

mm

Nominal

diameter

over

screen

mm

max

outer

diameter

mm

min

bending

radii

fixed

mm

min

bending

radii

flexing

mm

Net

weight

kg/km

unenclosed

Touching

A

3 x 1.5 5emC 3015 24 x 0.31 8.4 10.8 54 108 173 15

3 x 2.5 5emC 3025 40 x 0.31 9.9 12.5 63 125 240 22

4 x 1.5 5emC 4015 24 x 0.31 11.2 13.00 69 92 203 18

4 x 2.5 5emC 4025 40 x 0.31 13.3 14.00 100 125 288 26

4 x 4 5emC 4040 48 x 0.31 14.7 15.50 124 155 373 34

3 x 6 + 3 x 1.5 5emC 4060 72 x 0.31 17.4 17.40 136 170 532 44

3 x 10 + 3 x 1.5 5emC 4100 76 x 0.41 19.6 19.60 156 195 720 61

3 x 16 + 3 x 2.5 5emC 4160 117 x 0.41 22.6 23.10 168 210 1006 82

3 x 25 + 3 x 4 5emC 4250 180 x 0.41 26.4 27.00 196 245 1454 108

Selection and ordering data

* For larger conductor sizes, refer Protoflex - EMV - FC

Page 14: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

12

PROTOFLEX - EMV - FCXLPE insulated, UV stabalised EMC Cable

APPLICATIONSpecifically designed low capacitance screened cable for connection between AC variable speed drives and motors. Suitable for fixed installation and occasional freely flexing applications in dry damp and wet conditions. U.V stabilised for outdoor use.Not suitable for direct installation into the ground or submersion in water.DesIgNElectromagnetic compatibility (EMC) is the ability of electrical or electronic equipment to function normally in an environment without being effected by (EMI) electromagnetic and (RFI) radio frequency interferences or in turn disturbing the environment by transmitting EMI or RFI. The Siemens PROTOFLEX -EMV screened power cable consists of finely stranded copper conductors with Cross Linked Poly Ethylene (XLPE) insulation covered with a tinned copper braided screen and a PVC orange, transparent sheath. For cable cross sections 16mm² or greater the earth conductor is divided evenly into 3 seperate cores and uniformally located in the intersticial gaps around the power cores. This achieves a truly concentric design in accordance with the EMC standards.The overall tinned copper braid screen is specifically designed for optimum Electromagnetic Compatibility (EMC) by taking into account the percentage coverage, braid fan angle, and wire gauge which all results in a very low transfer resistance. The screen offers a low DC resistance affording protection from low frequency interference such as AC harmonics.The cable is in accordance with AS 1125 for the conductors and AS 1347 for the sheath. Fire performance is according to IEC 06332- 1

OPERATING TEMPERATURE• Minimum permissible ambient temperature -40°C• Maximum permissible conductor temperature 90°C• Maximum permissible short circuit temperature 250°C• Minimum ambient temperature for optimum fully flexible operation -5°C

CuRReNT CARRYINg CAPACITYCurrent ratings are based on continuous operation at an ambient temperature of 40°C. At other temperatures these values must be converted using the following table.

mINImum BeNDINg RADIIFor recommended bending radii refer to the selection and ordering data tables.

CORe COLOuR IDeNTIfICATION4 core - brown, blue, black, green/yellow

VOLTAge RATINgRated AC voltage: Uo/U = 0.6kV/1kVRated DC voltage: Uo/U = 0.9/1.8kVAC test voltage: = 5kV

°C 15 20 25 30 35 40 45 50 55 60 65 70 75 80 Factor 1.26 1.20 1.15 1.12 1.05 1. 0.94 0.88 0.81 0.73 0.65 0.57 0.47 0.34

Page 15: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

13

No. of

cores

and

conductor

rated

cross-section

mm²

Part No. Conductor

design

approx. No. of

strands

x max. strand

diameter

mm

Operating

capacitance

nf/Km

Nominal

diameter

over

screen

mm

max

outer

diameter

mm

min

bending

radii

fixed

mm

min

bending

radii

flexing

mm

Net

weight

kg/km

unenclosed

Touching

A

4 x 1.5 5De6 600 28 x 0.25 130 8.4 11.5 69 92 150 21

4 x 2.5 5De6 601 46 x 0.25 145 9.4 13.0 100 125 205 27

4 x 4 5De6 602 5 x 0.30 145 11.6 15.5 124 155 320 37

4 x 6 5De6 603 77 x 0.30 160 12.8 17.0 136 170 410 48

4 x 10 5De6 604 78 x 0.39 185 15.3 19.5 156 195 600 67

3 x 16 + 3 x 2.5 5De6 605 26 x 0.39 235 16.2 21.0 168 210 770 90

3 x 25 + 3 x 4 5De6 606 96 x 0.39 245 19.8 24.5 196 245 1110 119

3 x 35 + 3 x 16/3 5De6 607 27 x 0.39 270 22.5 28.0 224 280 1510 147

3 x 50 + 3 x 25/3 5De6 608 388 x 0.39 270 26.7 33.0 264 330 2140 184

3 x 70 + 3 x 35/3 5De6 610 553 x 0.39 295 30.6 37.0 296 370 2860 228

3 x 95 + 3 x 50/3 5De6 611 729 x 0.39 300 35.1 42.0 336 420 3740 274

3 x 120 + 3 x 50/3 5De6 612 932 x 0.39 312 39.6 46.5 372 465 4810 320

3 x 150 + 3 x 70/3 5De6 613 66 x 0.39 315 44.3 51.5 412 515 5850 368

3 x 185 + 3 x 95/3 5De6 614 425 x 0.39 315 48.9 57.0 456 570 7100 420

3 x 240 + 3 x 120/3 5De6 615 887 x 0.39 320 55.8 64.5 516 645 9400 498

3 x 300 + 3 x 150/3 5De6 616 2350 x 0.39 330 62.9 72.0 576 720 11680 576

Selection and ordering data

PROTOFLEX - EMV - FC XLPE insulated, UV stabalised EMC Cable

Page 16: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

14

APPLICATION

PROTOFLEX® PVC control cables are specially suitable for use as flexible control cables.• Fans and air-conditioning systems• Machine tools• Production and processing machines• Industrial robots

DesIgNPROTOFLEX® PVC control cables consist of finely stranded copper conductors with V75 PVC insulation. The high grade PVC sheath is resistant to oil, grease and chemicals. Designed for moderate mechanical loading, in dry, damp and wet areas and in hazardous areas. Outdoor use is possible, provided that the cables are protected from direct sunlight and are permanently installed.

sPeCIAL feATuRessuitable for use Burning behavior in accordance with DINin hazardous areas VDE 0472 Part 804, Test B (IEC 332-1)Voltages 300/500 V Rated voltage 318/550 V HIghest permissible operating voltage - 3 phase and single phase operation - in DC operation 2 kV Test voltageCertifi cation VDE Reg. No. 7042standards Based on DIN VDE 0281-13

TeChNICAL INfORmATIONCable construction is based on DIN VDE 0281-13• Finely-stranded bare copper conductors according to VDE 0295 Class 5• Insulation of special polyvinyl chloride (PVC)• PVC inner sheath over laid-up cores in shielded versions• Grey PVC outer sheath, largely resistant to oil and chemicals

CONTINuOus TeNsILe LOADThe maximum allowable tensile stress for operation of cables with mobile equipment is 15 N per mm².The maximum allowable tensile stress is 50 N mm² for fixed installations.

PeRmIssIBLe TemPeRATuReAt conductor: free-flexing +5°C to + 70°C fixed - 40°C to + 70°CBending radii: fixed 4 d free-flexing 7.5 d d= outer diameter of cable

CuRReNT CARRYINg CAPACITYThe current carrying capacities are based on a continuous operating temperature of 40°C. At other temperatures these values must be converted using the following factors

VOLTAge RATINg• Rated voltage:: Uo/U = 300/500V• AC test voltage: = 2kV

*The cable is designated 300/500V in accordance with VDE/IEC and meets the Australian standard for the stated voltage rating AS 1125, AS 3147.

CORe COLOuR IDeNTIfICATIONAll control cores are black, sequentially numbered and include a green/yellow earth core.

°C 15 20 25 30 35 40 45 50 55 60 65 70 75 80 Factor 1.26 1.20 1.15 1.12 1.05 1.00. 0.94 0.88 0.81 0.73 0.65 0.57 0.47 0.34

PROTOFLEX PVCPVC control cables

Page 17: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

15

Selection and ordering data

No. of

cores

x

Conductor

cross-section

mm²

Part No. Approx. No.

of strands

x

max. strand

diameter

mm

Cable

overall

diameter

mm

unenclosed

Touching

A

2 x 0.5 5De7 026 16 x 0.21 4.8 8

3 x 0.5 5De7 001 16 x 0.21 5.1 8

4 x 0.5 5De7 002 16 x 0.21 5.6 8

5 x 0.5 5De7 003 16 x 0.21 6.2 8

7 x 0.5 5De7 004 16 x 0.21 6.8 8

12 x 0.5 5De7 005 16 x 0.21 9.2 8

18 x 0.5 5De7 010 16 x 0.21 10.8 8

25 x 0.5 5De7 012 16 x 0.21 13.1 8

32 x 0.5 5De7 014 16 x 0.21 14.2 8

40 x 0.5 5De7 016 16 x 0.21 16.1 8

52 x 0.5 5De7 027 16 x 0.21 17.7 8

No. of

cores

x

Conductor

cross-section

mm²

Part No. Approx. No.

of strands

x

max. strand

diameter

mm

Cable

overall

diameter

mm

unenclosed

Touching

A

2 x 0.75 5De7 040 24 x 0.21 5.2 10

3 x 0.75 5De7 041 24 x 0.21 5.6 10

4 x 0.75 5De7 042 24 x 0.21 6.2 10

5 x 0.75 5De7 043 24 x 0.21 6.8 10

7 x 0.75 5De7 044 24 x 0.21 7.5 10

12 x 0.75 5De7 045 24 x 0.21 10.0 10

18 x 0.75 5De7 050 24 x 0.21 12.0 10

25 x 0.75 5De7 052 24 x 0.21 14.5 10

34 x 0.75 5De7 055 24 x 0.21 16.5 10

42 x 0.75 5De7 057 24 x 0.21 17.9 10

50 x 0.75 5De7 058 24 x 0.21 19.6 10

PROTOFLEX PVCPVC control cables

Page 18: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

16

PROTOFLEX PVCPVC control cables

Selection and ordering data

No. of

cores

x

Conductor

cross-section

mm²

Part No. Approx. No.

of strands

x

max. strand

diameter

mm

Cable

overall

diameter

mm

unenclosed

Touching

A

2 x 1.0 5De7 080 32 x 0.21 5.7 13

3 x 1.0 5De7 081 32 x 0.21 6.1 13

4 x 1.0 5De7 082 32 x 0.21 6.7 13

5 x 1.0 5De7 083 32 x 0.21 7.4 13

7 x 1.0 5De7 084 32 x 0.21 8.3 13

12 x 1.0 5De7 085 32 x 0.21 10.9 13

18 x 1.0 5De7 090 32 x 0.21 13.1 13

25 x 1.0 5De7 093 32 x 0.21 15.9 13

34 x 1.0 5De7 096 32 x 0.21 18.1 13

41 x 1.0 5De7 098 32 x 0.21 19.6 13

50 x 1.0 5De7 102 32 x 0.21 21.5 13

No. of

cores

x

Conductor

cross-section

mm²

Part No. Approx. No.

of strands

x

max. strand

diameter

mm

Cable

overall

diameter

mm

unenclosed

Touching

A

2 x 1.5 5De7 120 28 x 0.26 6.3 16

3 x 1.5 5De7 121 28 x 0.26 6.7 16

4 x 1.5 5De7 122 28 x 0.26 7.4 16

5 x 1.5 5De7 123 28 x 0.26 8.3 16

7 x 1.5 5De7 124 28 x 0.26 9.1 16

12 x 1.5 5De7 125 28 x 0.26 12.1 16

18 x 1.5 5De7 128 28 x 0.26 14.5 16

25 x 1.5 5De7 133 28 x 0.26 17.7 16

34 x 1.5 5De7 135 28 x 0.26 19.9 16

42 x 1.5 5De7 136 28 x 0.26 21.6 16

50 x 1.5 5De7 137 28 x 0.26 23.8 16

Page 19: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

17

PROTOFLEX PVCPVC control cables

Selection and ordering data

No. of

cores

x

Conductor

cross-section

mm²

Part No. Approx. No.

of strands

x

max. strand

diameter

mm

Cable

overall

diameter

mm

unenclosed

Touching

A

2 x 2.5 5De7 160 48 x 0.26 7.7 23

3 x 2.5 5De7 161 48 x 0.26 8.3 23

4 x 2.5 5De7 162 48 x 0.26 9.2 23

5 x 2.5 5De7 163 48 x 0.26 10.1 23

7 x 2.5 5De7 164 48 x 0.26 11.2 23

12 x 2.5 5De7 165 48 x 0.26 15.2 23

18 x 2.5 5De7 170 48 x 0.26 18.1 23

25 x 2.5 5De7 172 48 x 0.26 22.1 23

34 x 2.5 5De7 175 48 x 0.26 25.0 23

50 x 2.5 5De7 178 48 x 0.26 30.0 23

Page 20: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

18

SINGLE CORE 3.3kV 110° FLEXHighly flexible, single core rubber cables

APPLICATION• Internal switchboard cabling• Sub-mains• Electrical traction vehicles• Battery bank connections• Machine & equipment cabling• Steelworks, cranes & hoists• Stacker & reclaimer cabling• DC wiring• 415/ 1000V installations

• Submersible to 100 metres

DesIgNlSingle core 3.3kV flex cables consist of extra finely stranded tinned copper conductors laid up to provide an extremely flexible design. The Protolon R-EP-110 elastomer insulation is rated at 3.3kV with an oil resistant, flame retardant PCP sheath completing the construction.

The cable is in accordance with AS1125, AS3116 and VDE0250 part 602. for NSGAFoeu.

Permissable thermal short-circuit currents for 1 s duration (conductor temperature at start of short-circuit: 110°C):

Permissible short-circuit currents for other durations are available.

The thermal as well as the dynamic short-circuit strength must be taken into account. The cables must in particular be firmly fixed to protect them from the effects of peak short-circuit currents.OPeRATINg TemPeRATuRe• Minimum permissible ambient temperature -40°C• Maximum permissible conductor temperature 110°C• Maximum permissible short circuit temperature 250°C• Minimum ambient temperature for optimum fully flexible operation -25°C

mINImum BeNDINg RADIIThe following minimum bending radii should be observed to ensure operating reliability. For fixed installation 6 x cable diameter When freely flexing 8 x cable diameter CuRReNT CARRYINg CAPACITYCurrent ratings are based on continuous operation at an ambient temperature of 40°C. At other temperatures these values must be converted using the following table.

Current ratings are based on AS/NZS 3008.1.1:1998. Table 8 Current- Carrying Capacities of Three Single-Core 0.6/1kV Sheathed and Unsheathed non-armoured cables R-E-110TeNsILe sTReNgThThe maximum allowable tensile stress is 15N/mm². This ensures no conductor damage will occur in operation.VOLTAge RATINg• Rated voltage: 0.6/1kV to 3.3kV AC• Maximum operating voltages in: 3 phase AC operation Uo/U = 2.1/3.6kV DC operation Uo/U = 2.7/5.4kV• AC test voltage = 6kVCuRReNT CARRYINg CAPACITYThe core insulation is white.

[mm²] 4 6 10 16 25 35 50 70 95 120 150 185 .... 240

[kA] ..0.488 0.732 1.22 1.95 3.05 4.27. 6.10 8.54 11.6 14.6 18.3 ....22.6 ... 29.3

°C 15 20 25 30 35 40 45 50 55 60 65 70 75 80 Factor 1.26 1.20 1.15 1.12 1.05 1.00. 0.94 0.88 0.81 0.73 0.65 0.57 0.47 0.34

Page 21: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

19

SINGLE CORE 3.3kV 110° FLEXHighly flexible, single core rubber cables

Selection and ordering data

No. of cores

x conductor

mm²

Part No. Approx No.

of strand

x max.

mm

Diameter

of bare

conductor

stand

mm

Cable

overall

diameter

min max

mm mm

Cable

weight

kg/km

Current carrying capacity when installed

unenclosed

spaced

A

unenclosed

spaced from

surface

A

unenclosed

Touching

A

enclosed

A

1x1.5 5Df2 043 28 x 0.26 1.5 5.7 6.2 47 31 27 25 22

1x2.5 5Df2 053 45 x 0.26 1.9 6.1 6.6 60 43 38 36 32

1 x 4 5Df2 063 51 x 0.31 2.5 6.6 7.1 77 57 50 47 41

1 x 6 5Df2 073 75 x 0.31 3.2 7.1 7.6 97 73 63 59 51

1 x 10 5Df2 103 77 x 0.41 4.1 8.6 9.1 153 99 86 81 71

1 x 16 5Df2 123 123 x .041 6.5 10.0 10.8 213 130 115 105 93

1 x 25 5Df2 133 190 x 0.41 6.8 12.0 12.8 328 175 155 145 125

1 x 35 5Df2 143 268 x 0.41 8.1 13.1 13.9 421 220 190 175 150

1 x 50 5Df2 153 384 x 0.41 9.6 14.5 15.3 562 265 230 215 180

1 x 70 5Df2 163 545 x 0.41 11.2 16.3 17.3 750 340 290 270 235

1 x 95 5Df2 173 724 x 0.41 13.2 16.6 19.6 997 420 365 340 285

1 x 120 5Df2 183 926 x 0.41 14.9 20.7 21.7 1259 490 420 395 335

1 x 150 5Df2 203 1154 x 0.41 16.6 22.7 23.7 1534 570 485 455 380

1 x 185 5Df2 213 1407 x 0.41 18.0 24.7 25.7 1853 660 560 530 450

1 x 240 5Df2 223 1866 x 0.41 21.2 27.9 29.4 2428 790 670 630 550

1 x 300 5Df2 233 1551 x 0.51 23.6 31.0 32.5 3006 910 780 730 630

1 x 400 5Df2 243 1995 x 0.51 27.2 32.5 39.5 4332 1070 910 850 720

Page 22: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

20

OZOFLEXHeavy duty EPR/CSP rubber flexible cables

APPLICATIONHeavy duty construction site leads for drills, pumps, • saws, kangosCranes, hoists & festoon systems• Stage & theatre power & lighting • Portable motors, generators & power supplies• Submersible to 100 metres plus•

DesIgNOZOFLEX is designed as a heavy duty flexible for dry, damp and wet environments, areas of stress caused by vibration or impact and is resistant to abrasion, exposure to radiated heat and chemical contamination. Because of the black, flame retardant CSP sheath OZOFLEX is suitable for areas subject to fire hazard and hazardous locations.

OZOFLEX cables consist of finely stranded copper conductors laid up to provide a flexible design. R-EP-90 elastomer insulation provides improved current capacities.

Cables above 16mm² and all control cables have an elastomer inner sheath. The CSP elastomer sheath (Hypalon) is oil resistant and flame retardant in accordance with VDE 0472.

The construction is in accordance with the Australian Standards AS 1125, AS 3191, AS 3116 and DIN/VDE 0282 IEC332-1 and CENELEC standards for O7RN.

OZOFLEX cables, covered by the Prescribed Items Act mandatory approval for flexible leads, are accordingly covered by Approval Certificate No. 11551.

OPeRATINg TemPeRATuReMinimum permissible ambient temperature -40°C• Maximum permissible short circuit temperature • 250°CMinimum ambient temperature for optimum fully • flexible operation -25°C

mINImum BeNDINg RADIIThe following minimum bending radii should be observed to ensure operating reliability.

For fixed installation 4 x cable diameter• When freely flexing 5 x cable diameter•

CuRReNT CARRYINg CAPACITYCurrent ratings are based on continuous operation at an ambient temperature of 40°C. At other temperatures these values must be converted using the following table.

When installed on spring operated reelers the following de-rating factors are to be applied:1 layer on real 0.80 2 layers 0.61 3 layers 0.49VOLTAge RATINg

Rated voltage: Uo/U = 0.6/1kV• Maximum operating voltages in: •

3 phase AC operation Uo/U = 0.7/1.15kV DC operation Uo/U = 0.9/1.73kV

AC test voltage = 2.5kV•

*The cable is designated 450/750V with EI1 insulation compound in accordance with VDE/IEC and meets or exceeds the Australian Standard AS 3116 for the voltage rating of 0.6/1kV, R-EP-90.

CORe COLOuR IDeNTIfICATIONSingle Core black3 Core blue, brown, green/yellow4 Core brown, black, green/yellow, grey5 Core blue, brown, black, green/yellow, greyMulti core black insulation sequentially numbered including a green/yellow earth core.TeNsILe sTReNgThThe maximum allowable tensile stress is 15N/mm2. This ensures no conductor damage will occur in operation.

°C 15 20 25 30 35 40 45 50 55 60 65 70 75 80 Factor 1.26 1.20 1.15 1.1 1.05 1 0.94 0.88 0.81 0.73 0.65 0.57 0.47 0.34

Page 23: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

21

OZOFLEXHeavy duty EPR/CSP rubber flexible cables

Number of Cores x

Conductor size

mm²

Part No. Approx. No of strands x

max. strand

Diameter

mm

Diameter of bare

conductor

mm

Cable Overall Diameter

min mm max mm

Cable Weight

kg/km

unenclosed Touch

A

Without a green/

Yellow earth

2 x 1.5 5Dh2 204-5 30 x 0.26 1.5 9.0 11.5 135 20

2 x 2.5 5Dh2 205-5 50 x 0.26 1.9 10.5 13.5 195 28

2 x 4 5Dh2 206-5 56 x 0.31 2.5 12.0 15.0 270 37

OZOfLeX including

a green/yellow

earth core

3g1 5Dh2 303-5 32 x 0.21 1.2 8.6 10.5 130 14

3g1.5 5Dh2 304-5 30 x 0.26 1.5 9.6 11.0 165 19

3g2.5 5Dh2 305-5 50 x 0.26 1.9 11.5 13.0 235 26

3g4 5Dh2 306-5 56 x 0.31 2.5 13.0 15.0 320 35

3g6 5Dh2 307-5 84 x 0.31 3.2 14.5 16.5 495 45

3g10 5Dh2 310-5 80 x 0.41 4.1 20.0 22.5 880 62

3g16 5Dh2 312-5 126 x 0.41 5.7 22.5 26.5 1090 83

4g1 5Dh2 403-5 32 x 0.21 1.2 9.8 10.2 140 14

4g1.5 5Dh2 404-5 30 x 0.26 1.5 10.5 12.5 192 19

4g2.5 5Dh2 405-5 50 x 0.26 1.9 12.5 14.0 290 26

4g4 5Dh2 406-5 56 x 0.31 2.5 14.5 16.5 395 35

OZOfLeX

Aust. Core

Colours

R,W,B,B,g/Y

5g2.5 5Dh2 505-6 50 x 0.26 1.9 13.5 15.8 345 26

5g4 5Dh2 506-6 56 x 0.31 2.5 16.0 18.8 485 35

5g6 5Dh2 907-6 84 x 0.31 3.2 18.0 22.0 760 45

5g10 5Dh2 510-6 80 x 0.41 4.1 24.0 27.0 1300 62

5g16 5Dh2 512-6 126 x 0.41 5.7 27.0 32.5 1680 83

5g25 5Dh2 513-6 196 x 0.41 6.9 32.5 37.0 2470 110

5g35 5Dh2 514-6 296 x 0.41 8.1 37.5 41.5 3306 135

OZOfLeX

including a

green/yellow

earth core

7g1.5 5Dh2 580-5 30 x 0.26 1.5 14.0 17.5 355 19

10g1.5 5Dh2 938-4 30 x 0.26 1.5 18.5 20.5 610 19

12g1.5 5Dh2 583-5 30 x 0.26 1.5 19.2 20.2 520 19

7g2.5 5Dh2 590-5 50 x 0.26 1.9 16.5 20.0 505 19

8g2.5 5Dh2 591-5 50 x 0.26 1.9 18.0 21.5 570 26

12g2.5 5Dh2 593-5 50 x 0.26 1.9 18.5 26.5 755 26

18g2.5 5Dh2 595-5 50 x 0.26 1.9 25.0 31.5 1100 26

24g2.5 5Dh2 596-5 50 x 0.26 1.9 28.5 35.0 1380 26

Selection and ordering data

Page 24: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

22

OZOFLEX (PLUS)Flexible cables for submersion in polluted liquids

APPLICATIONSewage treatment plants• Waste water pumps - effluent aerators• Abattoirs (high temp chemical cleaning)• Dairy industry• Mining - de-watering• Chemical plants & steelworks• Hygenic cleaning in breweries, food processing • plants etc.Water depth approx. 10m in waste water, up • to 500m in all other types

DesIgNOZOFLEX (PLUS) cables consist of finely stranded copper conductors laid up to provide a flexible design. R-EP-90 elastomer insulation provides improved current capacities. Cables above 16mm2 and all control cables include an additional elastomer inner sheath and all cables up to 6mm2 have tinned conductors. The specially compounded heavy duty CPE Elastomer sheath (Hypalon) is oil resistant and flame retardant and resists the effects of water absorption.

The construction is in accordance with the Australian Standards AS 1125, AS 3191, AS 3116 and DIN/VDE 282 and CENELEC STANDARDS for 07RN, IEC 60332-1.

OPeRATINg TemPeRATuReMinimum permissible ambient temperature -40°C• Maximum permissible short circuit temperature • 250°CMinimum ambient temperature for optimum fully • flexible operation -25°C

mINImum BeNDINg RADII

The following minimum bending radii should be observed to ensure operating reliability.

For fixed installation 4 x cable diameter• When freely flexing 5 x cable diameter •

CuRReNT CARRYINg CAPACITYCurrent ratings are based on continuous operation at an ambient temperature of 40°C. At other temperatures these values must be converted using the following table.

VOLTAge RATINgRated voltage: Uo/U = 0.6/1kV• Maximum operating voltages in: •

3 phase AC operation Uo/U = 0.7/1.15kV DC operation Uo/U = 0.9/1.73kV

AC test voltage = 2.5kV•

* The cable is designated 450/750V with EI1 insulation

compound in accordance with VDE/IEC and meets or exceeds the Australian Standard AS 3116 for the voltage rating of 0.6/1kV, R-EP-90.

CORe COLOuR IDeNTIfICATIONSingle Core black3 Core blue, brown, green/yellow4 Core brown, black, green/yellow, grey5 Core blue, brown, black, green/yellow, greyMulti core black insulation sequentially numbered including a green/yellow earth core.

TeNsILe sTReNgThThe maximum allowable tensile stress is 15N/mm². This ensures no conductor damage will occur in operation.

°C 15 20 25 30 35 40 45 50 55 60 65 70 75 80 Factor 1.26 1.20 1.15 1.1 1.05 1 0.94 0.88 0.81 0.73 0.65 0.57 0.47 0.34

Page 25: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

23

OZOFLEX (PLUS)Flexible cables for submersion in polluted liquids

Number of Cores x

Conductor size

mm²

Part No. Approx. No of

strands x max.

strand Diameter

mm

Diameter of bare

conductor

mm

Cable Overall Diameter

min mm max mm

Cable Weight

kg/km

unenclosed Touch

A

OZOfLeX (PLus)

including a green/

yellow earth core

4g1.5 5Dh1 021 27 x 0.26 1.8 10.5 12.0 192 19

4g2.5 5Dh1 022 45 x 0.26 2.6 12.5 14.0 279 26

4g4 5Dh1 023 50 x 0.31 3.2 14.5 16.1 388 35

4g6 5Dh2 901 75 x 0.31 3.9 16.5 18.6 530 45

4g10 5Dh1 025 78 x 0.41 5.1 22.2 24.2 940 62

4g16 5Dh1 026 124 x 0.41 6.3 26.1 29.1 1310 83

4g25 5Dh1 027 192 x 0.41 7.8 29.8 33.8 1890 110

4g35 5Dh1 028 271 x 0.41 9.2 34.6 37.6 2460 135

4g50 5Dh1 030 388 x 0.41 11.0 40.3 43.3 3390 170

4g70 5Dh1 031 551 x 0.41 11.3 43.0 48.5 4450 215

4g95 5Dh1 032 733 x 0.41 13.2 49.0 55.0 5830 265

4g120 5Dh1 033 938 x 0.41 15.0 53.0 60.0 7140 305

OZOfLeX (PLus)

with pilots

4g1.5 + 2 x 1.5 5Dh1 069 28 x 0.26 1.5 14.0 16.0 310 19

4g2.5 + 2 x 1.5 5Dh1 070 45 x 0.26 1.9 16.0 18.5 420 26

4g4 + 2 x 1.5 5Dh1 071 51 x 0.31 2.5 19.0 21.5 570 35

4g6 + 2 x 1.5 5Dh1 072 75 x 0.31 3.2 21.0 23.5 720 45

4g10 + 2 x 1.5 5Dh1 073 77 x 0.26 4.1 26.5 30.0 1170 62

4g16 + 2 x 1.5 5Dh1 275 123 x 0.41 5.6 26.5 30.0 1310 83

4g25 + 2 x 1.5 5Dh1 075 190 x 0.41 6.8 31.5 35.0 1910 110

4g35 + 2 x 1.5 5Dh1 076 268 x 0.41 8.1 35.0 38.5 2460 135

Selection and ordering data

Page 26: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

24

APPLICATION• Switchboard cabling• Coil & transformer wiring• High thermal stress resistant• Chemical & ceramic industry• Steelworks

DesIgNEVA 125 is a flexible elastomer insulated cable with improved thermal characteristics due to special cross linking together with an excellent resistance to oils, chemicals, abrasion and mechanical damage.

EVA 125 Flex cables consist of finely stranded tinned copper conductors laid up to provide a flexible design with a specially compounded R-EVA-125 synthetic rubber insulation for operation in elevated ambient temperatures. The cable is in accordance with the Australian Standards AS 1125, AS/NZS 5001-1 and DIN VDE 0282 pt 501 for H07G

The special Ethylene Vinyl Acetate compound is halogen free and exhibits low smoke generation in the event of fire and has a high resistance to absorption of oils and grease.

OPeRATINg TemPeRATuRe• Minimum and maximum permissible ambient temperature -40°C to +110°C• Maximum permissible conductor temperature 120°C• Maximum permissible short circuit temperature 250°C

mINImum BeNDINg RADIIThe following minimum recommended bending radii should be observed to ensure operating reliability.• For fixed installation 4 x cable diameter• When freely flexing 5 x cable diameter

CuRReNT CARRYINg CAPACITYCurrent ratings are based on a continuous operating ambient temperature of 40°C. At other temperatures these values must be converted using the following table.

TeNsILe sTReNgThThe maximum allowable tensile stress on the conductors is 15N/mm². This ensures no conductor damage will occur in operation.

VOLTAge RATINg• Rated voltage:: Uo/U = 0.6/1kV • Maximum operating voltages in: 3 phase AC operation Uo/U = 0.7/1.15kV DC operation Uo/U = 0.9/1.73kV• AC test voltage:: Uo/U = 2.5kVThe cable is designated 450/750V in accordance with VDE/IEC and meets or exceeds the Australian Standard AS3116 for the voltage rating 0.6/1kV

CORe COLOuR IDeNTIfICATIONThe cable is available in either black or orange as standard. Variations are available subject to manufacture length.

EVA 125 FLEXHigh temperature 125°c flame retardant halogen free flexible cables

°C 15 20 25 30 35 40 45 50 55 60 65 70 75 80 Factor 1.26 1.20 1.15 1.1 1.05 1 0.94 0.88 0.81 0.73 0.65 0.57 0.47 0.34

Page 27: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

25

EVA 125 FLEXHigh temperature 125°c flame retardant halogen free flexible cables

Number of Cores x Conductor size mm²

Insulation colour

Part No. Approx. No of

strands x max.

strand Diameter

mm

Diameter of bare

conductor

mm

Cable Overall Diameter

min mm max mm

Cable Weight

kg/km

unenclosed Touch

A

1 x 0.75 black 5DR7 051-5 24 x 0.21 1.3 2.5 3.2 15 18

1 x 1 black 5DR7 052-5 32 x 0.21 1.5 2.6 3.4 20 20

1 x 1.5 black 5DR7 053-5 30 x 0.26 1.8 2.9 3.7 25 25

1 x 2.5 black 5DR7 054-5 50 x 0.26 2.6 3.5 4.4 40 35

1 x 4 black 5DR7 055-5 56 x 0.31 3.2 4.2 5.5 60 47

1 x 6 black 5DR7 056-5 84 x 0.31 3.9 4.8 6.3 80 59

1 x 10 black 5DR7 057-5 80 x 0.41 5.1 6.0 7.9 130 81

1 x 16 black 5DR7 060-5 126 x 0.41 6.3 7.2 9.0 210 105

1 x 25 black 5DR7 061-5 196 x 0.41 7.8 8.7 11.0 320 145

1 x 35 black 5DR7 062-5 276 x 0.41 9.2 10.0 12.4 420 175

1 x 50 black 5DR7 063-5 396 x 0.41 11.0 11.8 15.4 595 215

1 x 70 black 5DR7 064-5 360 x 13.9 13.9 15.6 18.0 850 271

1 x 95 black 5DR7 065-5 475 x 0.51 15.1 16.5 19.1 985 340

Selection and ordering data

Page 28: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

26

APPLICATION• Switchboard & cubical wiring• Transformer and capacitor cabling• High output floodlights• Chemical & ceramic industry• Injection moulding & extruders• Steelworks / hot strip rolling mills• Foundries & cooking plants• Heating appliances• Motor rewinders

DesIgNSINOTHERM cables consist of fine stranded copper conductors laid up to provide a flexible design.Silicone insulation offers high resistance to increased ambient temperatures, however with a low mechanical resistance to cuts and tearing.

OPeRATINg TemPeRATuRe• Minimum and maximum permissible -55°C ambient temperature +180°C• Maximum permissible conductor temperature 180°C• Maximum permissible short circuit temperature 350°C• Minimum ambient temperature for optimum fully flexible operation -40°C

ResIsTANCe TO ChemICALsOccasional slight exposure to oil and grease is permitted but the cables must not lie continually in oil or grease. They must be protected against fuels and solvents by suitable insulation. In accordance with AS 3178 the single core 0.6/1kV SINOTHERM carries the SECV Approval No.89516V.

mINImum BeNDINg RADIIThe following minimum bending radii must be observed to ensure operating reliability.These are applicable for both sub-zero and elevated temperatures.• Fixed installation 4 x cable diameter• When freely flexing 5 x cable diameter

CuRReNT CARRYINg CAPACITYCurrent ratings are based on continuous operation at an ambient temperature of 150°C per the following table when installed unenclosed and touching.

CuRReNT CARRYINg CAPACITYCurrent ratings are based on continuous operation at an ambient temperature of 150°C per the following table when installed unenclosed and touching.

At other temperatures these values must be converted using the following table.

Current ratings are based on continuous operation at an ambient temperature of 40°C per the following table when installed unenclosed and touching.

At other temperatures these values must be converted using the following table.

VOLTAge RATINg• Rated voltage:: • Single core Uo/U = 0.6/1kV• Multi core & glass braided: Uo/U = 300/500V

SINOTHERMHigh temperature 180°c silicone flexible cables

Conductor Size 0.75 1.0 1.5 2.5 4 6 10 16 25 35 50 70 95

Amps 15 19 24 32 42 54 73 98 129 158 198 245 292

Ambient temp. up to °C 150 155 160 165 170 175 180

Current capacity as a % of values above 100 91 82 71 58 41 23

Conductor Size 0.75 1.0 1.5 2.5 4 6 10 16 25 35 50 70 95

Amps 18 21 27 38 51 65 92 123 163 202 294 364 433

°C 40 45 50 55 60 65 70 75

Factor 1.0 0.98 0.95 0.93 0.90 0.88 0.85 0.83

Page 29: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

27

SINOTHERMHigh temperature 180°c silicone flexible cables

No. ofcoresxConductorsize

mm2

Part No. Approx.No. of

strands xmax. strand

diameter

mm

Diameterof bare

conductor

Cableoverall

diameter

min maxmm mm

Cableweight

kg/km

1 x 1.5 5DR3 514 30 x 0.26 1.8 2.9 3.9 20

1 x 2.5 5DR3515 50 x 0.26 2.6 3.5 4.6 30

1 x 4 5DR3 516 56 x 0.31 3.2 4.2 5.2 50

1 x 6 5DR3 517 84 x 0.31 3.9 4.8 6.7 65

1 x 10 5DR3 518 80 x 0.41 5.1 6.2 8.0 115

1 x 16 5DR3 520 126 x 0.41 6.3 7.2 9.3 180

1 x 25 5DR3 521 196 x 0.41 7.8 8.7 11.4 275

1 x 35 5DR3 522 276 x 0.41 9.2 10.0 13.4 365

1 x 50 5DR3 523 396 x 0.41 11.0 11.8 15.4 520

1 x 70 5DR3 524 360 x 0.51 13.1 13.5 17.9 710

1 x 95 5DR3 525 475 x 0.51 15.1 15.4 20.0 930

No. ofcoresxConductorsize

mm2

Part No. Approx.No. of

strands xmax. strand

diameter

mm

Diameterof bare

conductor

Cableoverall

diameter

min maxmm mm

Cableweight

kg/km

1 x 1 5DR4 031-5 32 x 0.21 1.4 2.7 3.8 20

1 x 1.5 5DR4 041-5 30 x 0.26 1.7 3.2 4.3 27

1 x 2.5 5DR4 051-5 50 x 0.26 2.2 3.8 5.0 39

1 x 4 5DR4 061-5 56 x 0.31 3.1 4.3 5.6 54

1 x 6 5DR4 071-5 84 x 0.31 3.8 4.8 6.2 75

1 x 10 5DR4 101-5 80 x 0.41 5.0 6.0 8.2 130

1 x 16 5DR4 121-5 126 x 0.41 6.3 8.1 9.6 200

1 x 25 5DR4 131-4 196 x 0.41 8.0 9.7 12.0 305

1 x 35 5DR4 141-4 276 x 0.41 9.2 11.6 13.0 420

1 x 50 5DR4 151-4 396 x 0.41 11.0 13.5 16.0 595

single Core Insulated sinotherm

single Core sinotherm with glass fibre Braid (500V)

Page 30: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

28

SINOTHERMHigh temperature 180°c silicone flexible cables

No. ofcoresxConductorsize

mm²

Part No. Approx.No. of

strands xmax. strand

diameter

mm

Diameterof bare

conductor

Cableoverall

diameter

min maxmm mm

Cableweight

kg/km

3 x 0.75 5DR5 328-4 24 x 0.21 1.2 6.6 7.8 62

3 x 1.5 5DR5 348-4 30 x 0.26 1.7 8.0 9.6 98

4 x 1.5 5DR5 448-4 30 x 0.26 1.7 9.0 10.5 125

4 x 2.5 5DR5 458-4 50 x 0.26 2.2 10.5 12.5 185

5 x 1.5 5DR5 548-4 30 x 0.26 1.7 9.8 11.5 155

multicore sinotherm flexible Cables (500)

CORe COLOuR IDeNTIfICATION2 core - blue, brown3 core - blue, brown, green/yellow4 core - blue, brown, black, green/yellow5 core - blue, brown, black, green/yellow, blackA single core 660V is available in a range of colours for control wiring in black, red, pink, green/yellow, blue, orange, brown, white and grey.

Coloured Sinotherm Conductors tinned to AS 1125.

Page 31: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

29

CRANe, ReeLINg & hOIsT CABLes

Planoflex – Flat festoon crane cable. R-EP-90 elastomer insulation, HD-PCP-90 sheath, 90DegC rated, flame retardant, oil resistant.

Cordaflex (SMK) – Cable reelers, festoon systems and force guided applications where high dynamic and static forces are induced into the cable.

sPeCIAL PuRPOse eLAsTOmeR CABLes

Hydrofirm – Designed and approved for use in drinking water. For fresh, salt and lightly polluted water (60°C). Round version suitable for depths up to 2000mt.

Protomont HD – Heavy duty flexible for aggressive environments. Designed for use in open cut mining and quarries, industry and construction sites as well as agriculture use where heavy mechanical stresses occur.

mININg & hIgh VOLTAge ReeLINg CABLes

Protomont XHD – Extra heavy duty flexible mining cables. Combine flexibility with toughness to provide long service life in aggressive operating conditions.

Protolon – High voltage reeling & trailing cables. Designed to withstand the forces of reeling and force guidance systems on today’s mobile equipment. A range of designs available to suit all applications including stackers, reclaimers, shiploaders, cranes, shovels, dredges, electric drills and draglines.

120DegC sOLAR CABLes:Cable - Connectors – LeadsHalogen Free, Flame Retardant, Resistant to Oils & Grease, Ozone and UV Resistant, 120Deg rated.Can be used indoor, outdoor and in explosion hazardous areas.Meets guidelines for green star points on building projects endorsed for government rebates.

KabEx Australia is a authorised reseller of Siemens specialty cables. We can offer custom advice to suit any industrial application.

SIEMENS SPECIALTY CABLES

Page 32: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

30

APPLICATIONThe OSGP GRP junction boxes have proven their use in many sectors of industry. The OSGP GRP enclosure comprise 5 sizes ofenclosure manufactured in Glass Fibre Reinforced Polyester (GRP). This material is highly resistant to contamination fromoils, fats, aliphatic and also is suitable for LSOH (low smoke zero halogen) applications.Polyester gives excellent mechanical strength and life expectancy.The OSGP enclosures are suitable for use with in hazardous areas and can be supplied certificates, such as ATEX and IECEx

TeChNICAL INfORmATION / sPeCIfICATIONsMaterial : Glass Fibre Reinforced Polyester (GRP)Area Classification : Zone 1, Zone 2, Zone 21 and Zone 22Ingress Protection : IP66, IP67 -EN/IEC 60529Wide Operating Temperature : -70 ~ +130Certificate : ATEX Eex e , IECEx eImpact Resistance : 7Nm (EN50014)Color : RAL9005 BlackToxicity : Low Smoke Halogen-FreeV-0 Self Extinguishing, UL94Gasket : Silicon rubberMounting : Integral 4.5mm clearance holesmoulded into the bodyEarthing : Optional M6 internal/external earth stud,brass or stainless steelSurface Insulation Resistance : 106Ohm ≤black≤109Ohm,

CeRTIfICATION:IECEx. ATEX

TYPe DesIgNATION:The COMPLETE MODEL No is as follows :OSGP1 4 M O T 1

mODeL TYPe

GRP Junction BoxesOSGP Type

(** Terminal block is WDu series or equivalent products.)

(** T+B : Top+Bottom, L+R: Left+Right)

Individual product data sheets available from www.oscgglands.com.au

1 2 3 4 5 6

Type

W(width)*h(height)*D(depthWeight

empty(g) Pack Qty

W H D

OsgP1 122 120 90 750g 100

OsgP2 220 120 90 1060g

OsgP3 160 160 90 1060g 100

OsgP4 260 160 90 23 pcs 100

OsgP5 360 160 90 2150g

OsgP1 OsgP2 OsgP3 OsgP4 OsgP5

WDu2.5 1*12 1*30 1*20 1*36 1*52

WDu4 1*11 1*28 1*18 1*33 1*48

WDu6 1*11 1*22 1*13 1*27 1*40

No. DesCRIPTION sYmBOL DeTAIL

1

BAsIC mODe OsgP1 122*120*90(mm)

OsgP2 220*120*90(mm)

OsgP3 160*160*90(mm)

OsgP4 260*160*90(mm)

OsgP5 360*160*90(mm)

2

TB sIZe(sQ) 2.5 2.5sQ

04 4sQ

06 6sQ

10 10sQ

16 16sQ

35 35sQ

3eNTRY m meTRIC

ThReAD TYPe NPT NPT

4

eNTRY sIZe 0 m16 OR NPT 1/2"

1 m20 OR NPT 1/2"

2 m25 OR NPT 3/4"

3 m32 OR NPT 1"

5

eNTRY sIZe T TOP sIDe

B BOTTOm sIDe

L LefT sIDe

R ReghT sIDe

6

Q'TY Of 01 1eA

eNTRY(eA) 02 2eA

03 3eA

- --

52 52eA

OsgB1 OsgB2 OsgB3 OsgB4 OsgB5

T + B L+R T + B L+R T + B L+R T + B L+R T + B L+R

m20/

NPT1/2"4 2 6 2 8 6 14 6 20 6

m25/

NPT3/4"2 1 5 1 3 2 6 2 9 2

m32/

NPT1"1 1 3 1 2 1 4 1 6 1

Page 33: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

31

fLAmePROOf & INCReAseD sAfeTY

APPLICATIONFor use with Non armoured cable in hazardous area. Single compression for outer jacket of cable.

PROTeCTION: Exd IIC/Exe II/ExtD A21, IP67Suitable for use in Zone1, 2, 21 and 22.

CeRTIfICATION:IECEx, Atex Nemko, GOST R

mATeRIAL:Brass with Nickle platedFor Stainless Steel add /SS to part number

Non Armoured Cable Gland Exd IIC/Exe II/ExtD A21OSNJ-A2F Type

Part No. entry Thread size

Cable Outer Diameter

Thread Length

entry hole size

hexagon Dimensions 'h'

shroud size

OSNJA2F-16AM16 M16 3 - 7.5 15 17 H24 X 26 OSSH-16(B)

OSNJA2F-16BM16 M16 6.1 - 10 15 17 H24 X 26 OSSH-16(B)

OSNJA2F-16AM20 M20 3 - 7.5 15 17 H24 X 26 OSSH-16(B)

OSNJA2F-16BM20 M20 6.1 - 10 15 17 H24 X 26 OSSH-16(B)

OSNJA2F-20AM20 M20 10.1 - 13 15 21 H27 X 29 OSSH-20(B)

OSNJA2F-20BM20 M20 13.1 - 15 15 21 H27 X 29 OSSH-20(B)

OSNJA2F-25A M25 14 - 17.5 15 26 H32 X 34 OSSH-25(B)

OSNJA2F-25B M25 16.1 - 19.5 15 26 H32 X 34 OSSH-25(B)

OSNJA2F-32A M32 18.1 - 22 15 33 H39 X 41.5 OSSH-32(B)

OSNJA2F-32B M32 21 - 26 15 33 H39 X 41.5 OSSH-32(B)

OSNJA2F-40A M40 24 - 28 15 41 H48 X 51 OSSH-40(B)

OSNJA2F-40B M40 27 - 32 15 41 H48 X 51 OSSH-40(B)

OSNJA2F-50A M50 32.1 - 34 15 51 H58 X 62 OSSH-50(B)

OSNJA2F-50B M50 34.1 - 40 15 51 H58 X 62 OSSH-50(B)

OSNJA2F-63A M63 38 - 44 15 64 H73 X 78 OSSH-63(B)

OSNJA2F-63B M63 43 - 50 15 64 H73 X 78 OSSH-63(B)

OSNJA2F-63C M63 49 - 54 15 64 H73 X 78 OSSH-63(B)

OSNJA2F-75A M75 52 - 56 20 76 H85 X 90 OSSH-75(B)

OSNJA2F-75B M75 55 - 60 20 76 H85 X 90 OSSH-75(B)

OSNJA2F-75C M75 59 - 62 20 76 H85 X 90 OSSH-75(B)

OSNJA2F-75D M75 62.1 - 66 20 76 H85 X 90 OSSH-75(B)

OSNJA2F-90A M90 63 - 70 20 91 H103 X 113 OSSH-90(B)

OSNJA2F-90B M90 68 - 76 20 91 H103 X 113 OSSH-90(B)

OSNJA2F-100A M100 76.1 - 81 20 101 H112 X 120 OSSH-100(B)

OSNJA2F-100B M100 81.1 - 85 20 101 H112 X 120 OSSH-100(B)

NPT threads available upon request

No. DesCRIPTION sYmBOL DeTAIL

1

BAsIC mODe OsgP1 122*120*90(mm)

OsgP2 220*120*90(mm)

OsgP3 160*160*90(mm)

OsgP4 260*160*90(mm)

OsgP5 360*160*90(mm)

2

TB sIZe(sQ) 2.5 2.5sQ

04 4sQ

06 6sQ

10 10sQ

16 16sQ

35 35sQ

3eNTRY m meTRIC

ThReAD TYPe NPT NPT

4

eNTRY sIZe 0 m16 OR NPT 1/2"

1 m20 OR NPT 1/2"

2 m25 OR NPT 3/4"

3 m32 OR NPT 1"

5

eNTRY sIZe T TOP sIDe

B BOTTOm sIDe

L LefT sIDe

R ReghT sIDe

6

Q'TY Of 01 1eA

eNTRY(eA) 02 2eA

03 3eA

- --

52 52eA

Page 34: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

32

fLAmePROOf & INCReAseD sAfeTY

APPLICATION:To close unused cable gland entries and maintain the flameproof and increased safety integrity of the equipment

PROTeCTION: Exd IIC/Exe II/ExtD A21, IP66/67Suitable for use in Zone1, 2, 21 and 22.

CeRTIfICATION:IECEx, Atex Nemko, GOST R

mATeRIAL:Brass with Nickle PlatedFor Stainless Steel add /SS to part number

Stopping Plug Exd IIC/Exe II/ExtD A21OSSP-R & OSSP-H Type

hexagonal head replace R with h to part number

stopping Plug

metric Part Number

Thread

size

Thread

Length

Diameter

OSSP-R101/M16 M16 15 26

OSSP-R102/M20 M20 15 29

OSSP-R103/M25 M25 15 33

OSSP-R104/M32 M32 15 41

OSSP-R105/M40 M40 15 49

OSSP-R106/M50 M50 15 60

OSSP-R107/M63 M63 15 76

OSSP-R108/M75 M75 15 88

OSSP-R109/M90 M90 20 105

OSSP-R110/M100 M100 20 116

stopping Plug

NPT Part Number

Thread

size

Thread

Length

Diameter

OSSP-R102/NPT1/2 1/2"NPT 15 29

OSSP-R103/NPT3/4 3/4"NPT 16 33

OSSP-R104/NPT1 1"NPT 18 41

OSSP-R105/NPT11/4 1 1/4"NPT 19 49

OSSP-R106/NPT11/2 1 1/2"NPT 21 60

OSSP-R107/NPT2 2"NPT 24 76

OSSP-R108/NPT21/2 2 1/2"NPT 27 88

OSSP-R109/NPT3 3"NPT 30 105

OSSP-R109/NPT31/2 3 1/2"NPT 32 116

stopping Plug

Pg Part Number

Thread

size

Thread

Length

Diameter

OSSP-R101/PG7 PG7 6 18

OSSP-R101/PG9 PG9 7 22

OSSP-R101/PG11 PG11 7 27

OSSP-R102/PG13.5 PG13.5 7 28

OSSP-R103/PG16 PG16 7 30

OSSP-R104/PG21 PG21 8 35

OSSP-R105/PG29 PG29 8 46

OSSP-R106/PG36 PG36 9 58

OSSP-R107/PG42 PG42 10 65

OSSP-R108/PG48 PG48 10 71

Page 35: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

33

fLAmePROOf & INCReAseD sAfeTY

APPLICATION:Provides a means of connection between cable entry devices andequipment having dissimilar threads.

PROTeCTION: Exd IIC/Exe II/ExtD A21, IP66/67Suitable for use in Zone1, 2, 21 and 22

CeRTIfICATION:IECEx, Atex Nemko, GOST R

mATeRIAL:Brass with Nickle PlatedFor Stainless Steel add /SS to part number

Reducer Exd IIC/Exe II/ExtD A21OSRA Type

Other sizes available upon request

Reducer

Part Number

entry Thread size Dimensions

male female

OSRA-101/M1 M20 M16 H25 X 27

OSRA-102/M1 M25 M16 H30 X 33

OSRA-102/M2 M25 M20 H30 X 33

OSRA-103/M1 M32 M16 H38 X 41

OSRA-103/M2 M32 M20 H38 X 41

OSRA-103/M3 M32 M25 H38 X 41

OSRA-104/M1 M40 M20 H45 X 48

OSRA-104/M2 M40 M25 H45 X 48

OSRA-104/M3 M40 M32 H45 X 48

OSRA-105/M1 M50 M25 H55 X 59

OSRA-105/M2 M50 M32 H55 X 59

OSRA-105/M3 M50 M40 H55 X 59

OSRA-106/M1 M63 M32 H68 X 72

OSRA-106/M2 M63 M40 H68 X 72

OSRA-106/M3 M63 M50 H68 X 72

OSRA-107/M1 M75 M40 H82 X 88

OSRA-107/M2 M75 M50 H82 X 88

OSRA-107/M3 M75 M63 H82 X 88

OSRA-101/PM21 PG11 M16 H21 X 23

OSRA-101/PM11 PG13.5 M20 H25 X 27

OSRA-102/PM1 PG16 M16 H25 X 29

OSRA-102/PM2 PG16 M20 H25 X 29

OSRA-103/PM1 PG21 M20 H34 X 37

OSRA-103/PM2 PG21 M25 H34 X 37

OSRA-104/PM1 PG29 M20 H43 X 46

OSRA-104/PM2 PG29 M25 H43 X 46

OSRA-104/PM3 PG29 M32 H43 X 46

Reducer

Part Number

entry Thread size Dimensions

male female

OSRA-102/NM0 1/2"NPT M16 H30 X 33

OSRA-103/NM1 3/4"NPT M20 H38 X 41

OSRA-104/NM1 1"NPT M20 H45 X 48

OSRA-104/NM2 1"NPT M25 H45 X 48

OSRA-105/NM1 1 1/4"NPT M20 H55 X 59

OSRA-105/NM2 1 1/4"NPT M25 H55 X 59

OSRA-105/NM3 1 1/4"NPT M32 H55 X 59

OSRA-106/NM1 1 1/2"NPT M20 H68 X 72

OSRA-106/NM2 1 1/2"NPT M25 H68 X 72

OSRA-106/NM3 1 1/2"NPT M32 H68 X 72

OSRA-106/NM4 1 1/2"NPT M40 H68 X 72

OSRA-107/NM2 2"NPT M25 H82 X 88

OSRA-107/NM3 2"NPT M32 H82 X 88

OSRA-107/NM4 2"NPT M40 H82 X 88

OSRA-107/NM5 2"NPT M50 H82 X 88

OSRA-103/N1 3/4"NPT 1/2"NPT H38 X 41

OSRA-104/N1 1"NPT 1/2"NPT H45 X 48

OSRA-104/N2 1"NPT 3/4"NPT H45 X 48

OSRA-105/N1 1 1/4"NPT 1/2"NPT H55 X 59

OSRA-105/N2 1 1/4"NPT 3/4"NPT H55 X 59

OSRA-105/N3 1 1/4"NPT 1"NPT H55 X 59

OSRA-106/N1 1 1/2"NPT 3/4"NPT H68 X 72

OSRA-106/N2 1 1/2"NPT 1"NPT H68 X 72

OSRA-106/N3 1 1/2"NPT 1 1/4"NPT H68 X 72

OSRA-107/N1 2"NPT 1"NPT H82 X 88

OSRA-107/N2 2"NPT 1 1/4"NPT H82 X 88

OSRA-107/N3 2"NPT 1 1/2"NPT H82 X 88

stopping Plug

Pg Part Number

Thread

size

Thread

Length

Diameter

OSSP-R101/PG7 PG7 6 18

OSSP-R101/PG9 PG9 7 22

OSSP-R101/PG11 PG11 7 27

OSSP-R102/PG13.5 PG13.5 7 28

OSSP-R103/PG16 PG16 7 30

OSSP-R104/PG21 PG21 8 35

OSSP-R105/PG29 PG29 8 46

OSSP-R106/PG36 PG36 9 58

OSSP-R107/PG42 PG42 10 65

OSSP-R108/PG48 PG48 10 71

Page 36: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

34

fLAmePROOf & INCReAseD sAfeTY

APPLICATION:Provides a means of connection between cable entry devices and equipment having dissimilar threads.

PROTeCTION: Exd IIC/Exe II/ExtD A21, IP66/67Suitable for use in Zone1, 2, 21 and 22.

CeRTIfICATION:IECEx, Atex Nemko, GOST R

mATeRIAL:Brass with Nickle PlatedFor Stainless Steel add /SS to part number

Adaptor Exd IIC/Exe/ExtD A21OSAJ Type

Other sizes available upon request

Reducer

Part Number

entry Thread size Dimensions

male female

OSAJ-101/M1 M16 M20 H25 X 27

OSAJ-102/M1 M16 M25 H30 X 33

OSAJ-102/M2 M20 M25 H30 X 33

OSAJ-103/M1 M16 M32 H37 X 40

OSAJ-103/M2 M20 M32 H37 X 40

OSAJ-103/M3 M25 M32 H37 X 40

OSAJ-104/M1 M20 M40 H46 X 50

OSAJ-104/M2 M25 M40 H46 X 50

OSAJ-104/M3 M32 M40 H46 X 50

OSAJ-105/M1 M25 M50 H57 X 61

OSAJ-105/M2 M32 M50 H57 X 61

OSAJ-105/M3 M40 M50 H57 X 61

OSAJ-106/M1 M32 M63 H70 X 75

OSAJ-106/M2 M40 M63 H70 X 75

OSAJ-106/M3 M50 M63 H70 X 75

OSAJ-107/M1 M40 M75 H82 X 89

OSAJ-107/M2 M50 M75 H82 X 89

OSAJ-107/M3 M63 M75 H82 X 89

OSAJ-101/PM1 PG7 M20 H21 X 23

OSAJ-101/PM2 PG9 M20 H21 X 23

OSAJ-102/PM1 PG9 M25 H27 X 30

OSAJ-102/PM2 PG11 M25 H27 X 30

OSAJ-102/PM3 PG13.5 M25 H27 X 30

OSAJ-103/PM1 PG9 M32 H34 X 37

OSAJ-103/PM2 PG11 M32 H34 X 37

OSAJ-103/PM3 PG13.5 M32 H34 X 37

OSAJ-103/PM4 PG16 M32 H34 X 37

Reducer

Part Number

entry Thread size Dimensions

male female

OSAJ-101/NM1 1/2"NPT M20 H25 X 27

OSAJ-102/MN1 M20 1/2"NPT H25 X 27

OSAJ-101/NM1 1/2"NPT M20 H25 X 27

OSAJ-103/NM2 3/4"NPT M25 H30 X 33

OSAJ-103/NM3 3/4"NPT M32 H38 X 41

OSAJ-104/NM3 1"NPT M32 H38 X 41

OSAJ-105/NM4 1 1/4"NPT M40 H48 X 52

OSAJ-106/NM5 1 1/2"NPT M50 H55 X 59

OSAJ-107/NM6 2"NPT M63 H68 X 73

OSAJ-102/N1 1/2"NPT 3/4"NPT H30 X 33

OSAJ-103/N1 1/2"NPT 1"NPT H38 X 41

OSAJ-103/N2 3/4"NPT 1"NPT H38 X 41

OSAJ-104/N1 3/4"NPT 1 1/4"NPT H48 X 52

OSAJ-104/N2 1"NPT 1 1/4"NPT H48 X 52

OSAJ-105/N1 1"NPT 1 1/2"NPT H55 X 59

OSAJ-105/N2 1 1/4"NPT 1 1/2"NPT H55 X 59

OSAJ-106/N1 1 1/4"NPT 2"NPT H68 X 73

OSAJ-106/N2 1 1/2"NPT 2"NPT H68 X 73

OSAJ-107/N1 1 1/2"NPT 2 1/2"NPT H82 X 88

OSAJ-107/N2 2"NPT 2 1/2"NPT H82 X 88

Page 37: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

35

APPLICATIONFor application in installation areas with small amounts of space. Lock nut in any position.

PROTeCTION: Exd IIC/Exe II/ExtD A21, IP67Suitable for use in Zone1, 2, 21 and 22.

CeRTIfICATION:IECEx

mATeRIAL:Brass with Nickle platedFor Stainless Steel add /SS to part number

Elbow Exd IIC/Exe II/ExtD A21OSAE Types

Ordering Code examples

OSAE-M20(F)XM20(F) M20 Female to M20 Female

OSAE-M20(M)XM20(F) M20 Male to M20 Female

OSAE-M20(M)XM20(M) M20 Male to M20 Male

OSAE-M20(M)XNPT1/2(F) M20 Male to NPT 1/2" Female

OSAE-NPT1/2(M)XM20(F) NPT 1/2" Male to M20 Female

OSAE-NPT1/2(M)XNPT1/2(M) NPT 1/2" Male to NPT 1/2" Male

Phone for all other ordering code combinations as listed in above table

Round Type/

siz e

entry Thread size (m)D d s

L1L2 L

metric NPT OsAe-m OsAe-f OsAe-mf

OSAE-16 M16 1/2" 24 10.3 32 15 20 20 15 43

OSAE-20 M20 1/2" 27 15.2 34.5 16 20 20 16 43

OSAE-25 M25 3/4" 32 19.8 37 16 20 20 16 50

OSAE-32 M32 1" 39 26 43 18 20 20 18 62

OSAE-40 M40 1 1/4" 48 33 50 19 20 20 19 73

OSAE-50 M50 1 1/2" 58 43 57 21 25 25 21 85

OSAE-63 M63 2" 73 55 70 24 25 25 24 107

OSAE-75 M75 2 1/2" 85 68 76 24 25 25 24 118

Page 38: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

36

APPLICATIONOutdoor & Indoor. Industrial cable gland for use with non armoured cables.

PROTeCTION: IP67

ReguLATION:According to BS, IEC

mATeRIAL:Brass with Nickle PlatedFor Stainless Steel add /SS to part number

Metal Non Armoured Cable GlandOSNJ Type

Part No. entry Thread size Cable Outer Diameter

Thread Length entry hole size

hexagon Dimensions 'h'

shroud size

OSNJ-16AM16 M16 3 - 7.5 15 17 H24 X 26 OSSH-16(B)

OSNJ-16BM16 M16 6.1 - 10 15 17 H24 X 26 OSSH-16(B)

OSNJ-16AM20 M20 3 - 7.5 15 17 H24 X 26 OSSH-16(B)

OSNJ-16BM20 M20 6.1 - 10 15 17 H24 X 26 OSSH-16(B)

OSNJ-20AM20 M20 10.1 - 13 15 21 H27 X 29 OSSH-20(B)

OSNJ-20BM20 M20 13.1 - 15 15 21 H27 X 29 OSSH-20(B)

OSNJ-25A M25 14 - 17.5 15 26 H32 X 34 OSSH-25(B)

OSNJ-25B M25 16.1 - 19.5 15 26 H32 X 34 OSSH-25(B)

OSNJ-32A M32 18.1 - 22 15 33 H39 X 41.5 OSSH-32(B)

OSNJ-32B M32 21 - 26 15 33 H39 X 41.5 OSSH-32(B)

OSNJ-40A M40 24 - 28 15 41 H48 X 51 OSSH-40(B)

OSNJ-40B M40 27 - 32 15 41 H48 X 51 OSSH-40(B)

OSNJ-50A M50 32.1 - 34 15 51 H58 X 62 OSSH-50(B)

OSNJ-50B M50 34.1 - 40 15 51 H58 X 62 OSSH-50(B)

OSNJ-63A M63 38 - 44 15 64 H73 X 78 OSSH-63(B)

OSNJ-63B M63 43 - 50 15 64 H73 X 78 OSSH-63(B)

OSNJ-63C M63 49 - 54 15 64 H73 X 78 OSSH-63(B)

OSNJ-75A M75 52 - 56 20 76 H85 X 90 OSSH-75(B)

OSNJ-75B M75 55 - 60 20 76 H85 X 90 OSSH-75(B)

OSNJ-75C M75 59 - 62 20 76 H85 X 90 OSSH-75(B)

OSNJ-75D M75 62.1 - 66 20 76 H85 X 90 OSSH-75(B)

OSNJ-90A M90 63 - 70 20 91 H103 X 113 OSSH-90(B)

OSNJ-90B M90 68 - 76 20 91 H103 X 113 OSSH-90(B)

OSNJ-100A M100 76.1 - 81 20 101 H112 X 120 OSSH-100(B)

OSNJ-100B M100 81.1 - 85 20 101 H112 X 120 OSSH-100(B)

NPT threads available upon request

Page 39: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

37

APPLICATIONOutdoor & Indoor.For use with steel wire armoured cable.Single compression for outer jacket of cable.

ReguLATION:According to BS, IEC

PROTeCTION: IP66

mATeRIAL:Brass with Nickle platedFor Stainless Steel add /SS to part number

Armoured Cable GlandOSNJ-CW Type

Part No. entry Thread size

Cable Outer Diameter

Thread Length

entry hole size

Armour Range hexagon Dimensions

'h'

OSNJ-CW-16AM16 M16 8 - 13 15 17 0.9/1.25 H25 X 27

OSNJ-CW-16BM16 M16 12 - 15.1 15 17 0.9/1.25 H25 X 27

OSNJ-CW-16AM20 M20 8 - 13 15 17 0.9/1.25 H25 X 27

OSNJ-CW-16BM20 M20 12 - 15.1 15 17 0.9/1.25 H25 X 27

OSNJ-CW-20AM20 M20 13 - 17.6 15 21 0.9/1.25 H31 X 33

OSNJ-CW-20BM20 M20 16 - 19.6 15 21 0.9/1.25 H31 X 33

OSNJ-CW-25A M25 17.5 - 22 15 26 1.25/1.6 H36 X 39

OSNJ-CW-25B M25 21 - 26 15 26 1.25/1.6 H36 X 39

OSNJ-CW-32A M32 22 - 28 15 33 1.6/2.0 H45 X 49

OSNJ-CW-32B M32 27 - 32 15 33 1.6/2.0 H45 X 49

OSNJ-CW-40A M40 30 - 35 15 41 1.6/2.0 H55 X 59

OSNJ-CW-40B M40 35.1 - 40 15 41 1.6/2.0 H55 X 59

OSNJ-CW-50A M50 38 - 45 15 51 1.8/2.5 H68 X 73

OSNJ-CW-50B M50 43 - 50 15 51 1.8/2.5 H68 X 73

OSNJ-CW-63A M63 48 - 53 15 64 1.8/2.5 H82 X 88

OSNJ-CW-63B M63 51 - 56 15 64 1.8/2.5 H82 X 88

OSNJ-CW-63C M63 55 - 60 15 64 1.8/2.5 H82 X 88

OSNJ-CW-75A M75 56 - 62 15 76 1.8/2.5 H98 X106

OSNJ-CW-75B M75 62.1 - 66 15 76 1.8/2.5 H98 X106

OSNJ-CW-75C M75 66.1 - 70 15 76 1.8/2.5 H98 X106

OSNJ-CW-75D M75 68 - 75 15 76 1.8/2.5 H98 X106

OSNJ-CW-90A M90 74 - 83 20 91 1.8/3.0 H110 X 120

OSNJ-CW-90B M90 82 - 90 20 91 1.8/3.0 H110 X 120

OSNJ-CW-100A M100 89 - 94 20 101 1.8/3.0 H120 X 130

OSNJ-CW-100B M100 93 - 98 20 101 1.8/3.0 H120 X 130

NPT threads available upon request

Page 40: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

38

APPLICATIONCable Glands according toDIN Standard

mATeRIAL:Brass with Nickle Plated

APPLICATIONFor fitting over cable glands Glandsin inside or outside applications

mATeRIAL:EPDM CR70

mATeRIAL:for Armoured Cable glands for Non-Armoured Cable

OSSH-16(A)OSSH-20(A)OSSH-25(A)OSSH-32(A)OSSH-40(A)OSSH-50(A)OSSH-63(A)OSSH-75(A)

OSSH-16(A)OSSH-20(A)OSSH-25(A)OSSH-32(A)OSSH-40(A)OSSH-50(A)OSSH-63(A)OSSH-75(A)

Metal PG Thread Cable GlandOSPG Type DIN Standard

ShroudsOSSH TypeDIN Standard

Part No. entry Thread size

Cable Outer Diameter

Thread Length hexagon Dimensions 'h'

Length 'L'

metric Pg

OSPG-9 PG9 .7 - 8. 15 7 H19 X 22 20

OSPG-11 PG11 .9 - 11. 15 7 H23 X 27 21

OSPG-13.5 PG13.5 .9 - 11. 15 7 H24 X 28 22

OSPG-16 PG16 .12 - 14. 15 7 H26 X 30 24

OSPG-21 PG21 15 - 17 15 8 H31 X 35 25

OSPG-29 PG29 19 - 23 15 8 H42 X 46 26

OSPG-36 PG36 25 - 31 15 9 H52 X 58 30

OSPG-42 PG42 33 - 37 15 10 H60 X 65 36

OSPG-48 PG48 39 - 43 20 10 H66 X 71 37

Page 41: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

39

for stainless steel add /ss to part number

for stainless steel add /ss to part number

earth Tagmetric Part No. Description

OSET-101/M16 M16 Earth Tag

OSET-102/M20 M20 Earth Tag

OSET-103/M25 M25 Earth Tag

OSET-104/M32 M32 Earth Tag

OSET-105/M40 M40 Earth Tag

OSET-106/M50 M50 Earth Tag

OSET-107/M63 M63 Earth Tag

OSET-108/M75 M75 Earth Tag

OSET-109/M90 M90 Earth Tag

Teflon sealing Washer Description

OSSR-M16 M16 Sealing Washer

OSSR-M20 M20 Sealing Washer

OSSR-M25 M25 Sealing Washer

OSSR-M32 M32 Sealing Washer

OSSR-M40 M40 Sealing Washer

OSSR-M50 M50 Sealing Washer

OSSR-M63 M63 Sealing Washer

OSSR-M75 M75 Sealing Washer

OSSR-M90 M90 Sealing Washer

serrated Teeth Washer Description

OSTW-M16 M16 Stainless Steel Serrated Washer

OSTW-M20 M20 Stainless Steel Serrated Washer

OSTW-M25 M25 Stainless Steel Serrated Washer

OSTW-M32 M32 Stainless Steel Serrated Washer

OSTW-M40 M40 Stainless Steel Serrated Washer

OSTW-M50 M50 Stainless Steel Serrated Washer

OSTW-M63 M63 Stainless Steel Serrated Washer

OSTW-M75 M75 Stainless Steel Serrated Washer

OSTW-M90 M90 Stainless Steel Serrated Washer

metal Lock Nutmetric Part No. Description

OSLN-M16 M16 Metal Lock Nut

OSLN-M20 M20 Metal Lock Nut

OSLN-M25 M25 Metal Lock Nut

OSLN-M32 M32 Metal Lock Nut

OSLN-M40 M40 Metal Lock Nut

OSLN-M50 M50 Metal Lock Nut

OSLN-M63 M63 Metal Lock Nut

OSLN-M75 M75 Metal Lock Nut

OSLN-M90 M90 Metal Lock Nut

Page 42: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

40

KABEX Stainless Steel Cable Ties are Grade 316 Stainless and available in coated or uncoated versions, Standard widths of 4.6 mm or 7.9 mm and available in various lengths.

This tie is of a roller-ball design which is self locking and fast & easy to install. It can be tightened by hand or with a special tool.The normal operating range for the roller ball uncoated ties version is -80C to +538C approximately. For coated version normal operating range is -80C to +150C.

Fully coated roller ball tie (Patent Pending) is recommended for extreme cold conditions and offshore applications. Coating is non toxic halogen free Polyester. It is available in wide choice of colours.

Part Number Description Length

mm

Width

mm

max Bundle Dia

mm

sT125 125 x 4.6mm stainless steel uncoated 100 4.6 16

sT150 150 x 4.6mm stainless steel uncoated 150 4.6 32

sT200 200 x 4.6mm stainless steel uncoated 150 4.6 50

sT360 360 x 4.6mm stainless steel uncoated 360 4.6 100

sT520 520 x 4.6mm stainless steel uncoated 520 4.6 150

sT200h 200 x 7.9mm stainless steel uncoated 200 7.9 50

sT360h 360 x 7.9mm stainless steel uncoated 360 7.9 100

sT520h 520 x 7.9mm stainless steel uncoated 520 7.9 150

sT680h 680 x 7.9mm stainless steel uncoated 680 7.9 200

sT1000h 1000 x 7.9mm stainless steel uncoated 1000 7.9 300

sT200C 200 x 4.6mm stainless steel Coated 520 4.6 150

sT360C 360 x 4.6mm stainless steel Coated 680 4.6 200

sT200hC 200 x 7.9mm stainless steel Coated 520 7.9 150

sT360hC 360 x 7.9mm stainless steel Coated 680 7.9 200

Other sizes available for Coated Versions upon request

minimum Loop Tensile strength:4.6 mm width Un-coated (44.5 kg) 100 lbs 7.9 mm width Un-coated (111.2 kg) 250 lbs 4.6 mm width Coated (44.5 kg) 100 lbs 7.9 mm width Coated (55 kg) 120 lbs

stainless steel Cable TiesType: Roller Ballgrade : ss316

Cable Termination AccessoriesStainless Steel Cable Ties

Page 43: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

41

material specification:Made from U.L. approved nylon 6/6. Operating Temperature -40 to 85DegC Flambility rating: UL 94V-2. Black Weather Resistant Nylon with Carbonate "A" added for greater resistance to ultra violet in outdoor application.

specification:Made to comply with mil-spec drawing no. MS-3367 tensile strength meet or exceed MIL-S-23190E standard.

Approvals:UL approvedDVN approvedVDE approvedGL approvedLloyds Register approvedROHS Compliant

Cable Ties - Natural

Cable Ties - Black uV Resistant

Cable Ties - Light Duty

Part Number Description max. Bundle min. Loop Tensile strength

Dia (mm) Lbs Kg NewtonsCT100NT-100 CABLe TIe 100mm X 2.5mm NATuRAL 22 18 8 80

CT150NT-100 CABLe TIe 150mm X 3.6mm NATuRAL 36 40 18 178

CT200NT-100 CABLe TIe 203mm X 4.8mm NATuRAL 52 50 22 222

CT250NT-100 CABLe TIe 100mm X 2.5mm NATuRAL 68 50 22 222

CT300NT-100 CABLe TIe 300mm X 4.8mm NATuRAL 83 50 22 222

CT370NT-100 CABLe TIe 368mm X 4.8mm NATuRAL 105 50 22 222

CT380NThD CABLe TIe 380mm X 7.6mm NATuRAL 105 120 55 533

Part Number Description max. Bundle min. Loop Tensile strength

Dia (mm) Lbs Kg NewtonsCT100NT-100 CABLe TIe 100mm X 2.5mm BLACK 22 18 8 80

CT150NT-100 CABLe TIe 150mm X 3.6mm BLACK 36 40 18 178

CT200NT-100 CABLe TIe 203mm X 4.8mm BLACK 52 50 22 222

CT250NT-100 CABLe TIe 100mm X 2.5mm BLACK 68 50 22 222

CT300NT-100 CABLe TIe 300mm X 4.8mm BLACK 83 50 22 222

CT370NT-100 CABLe TIe 100mm X 2.5mm BLACK 105 50 22 222

CT380NThD CABLe TIe 380mm X 7.6mm BLACK 105 120 55 533

Cable Termination AccessoriesNylon Cable Ties

Part Number Description max. Bundle min. Loop Tensile strength

Dia (mm) Lbs Kg NewtonsCT200LDNT CABLe TIe 203mm X 2.5mm NATuRAL 55 18 8 80

CT200mDNT CABLe TIe 203mm X 3.6mm NATuRAL 53 40 18 178

CT200LDBK CABLe TIe 203mm X 2.5mm BLACK 55 18 8 80

CT200mDBK CABLe TIe 203mm X 3.6mm BLACK 53 40 18 178

Page 44: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

42

UL Approved Nylon 66, 94V-2IP68 RatingHalogen FreeROHS Compliant

Part Number Thread Cable OD:

(mm)

std Pack

mg12 m12 3 - 6.5 50

mg16 m16 5 - 10 50

mg20 m20 10 - 14 30

mg25 m25 13 - 18 16

mg32 m32 18 - 25 12

mg40 m40 22 - 32 6

mg50 m50 30 - 38 3

mg63 m63 34 - 44 2

Part No. W X h (mm) length

sD1525 15 X 25

2m

sD2525 25 X 25

sD2545 25 X 45

sD4545 45 X 45

sD6545 65 X 45

sD6565 65 X 65

sD70100 70 X 100

sD10075 100 X 75

sD100100 100 X 100

sD150100 150 X 100

Cable Termination AccessoriesIP68 NYLON CABLE GLAND

OPEN SLOTTED DUCTHigh impact, self extinguishing, warp proof 94V-0 PVCMax. Service Temperature: 85°CStandard colour: GreyBlue Intrinsically Safe version add BLUE to Part Number.

Page 45: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

43

Twin Bootlace Ferrules

Part Number Wire size

(mm²)

Dimensions (mm) Colour Pack size

L W TBLP025/100 0.25 10 6 0.75 Violet 100

BLP034/100 0.34 10 6 0.8 Pink 100

BLP050/100 0.5 14 8 1 White 100

BLP075/100 0.75 14 8 1.2 Blue 100

BLP100/100 1 14 8 1.4 Red 100

BLP150/100 1.5 14 8 1.7 Black 100

BLP250/100 2.5 14 8 2.2 grey 100

BLP400/100 4 17 10 2.8 Orange 100

BLP600/50 6 20 12 3.5 green 50

BLP1000/25 10 22 12 4.5 Brown 25

BLP1600/25 16 24 12 5.8 Ivory 25

BLP2500/10 25 28 16 7.3 Black 10

BLP3500/10 35 30 16 8.3 Red 10

BLP5000/10 50 36 20 10.3 Blue 10

BLP7000/5 70 37 21 13.5 Yellow 5

BLP9500/3 90 44 25 14.7 Red 3

BLP12000/3 120 48 27 16.7 Blue 3

BLP15000/3 150 58 32 19.5 Yellow 3

Part Number Wire size

(mm²)

Dimensions (mm) Colour Pack size

L W TBLPT050/100 2 x 0.5 15 8 1.5 White 100

BLPT075/100 2 x 0.75 15 8 1.5 grey 100

BLPT100/100 2 x 1 15 8 2.05 Red 100

BLPT150/100 2 x 1.5 16 8 2.3 Black 100

BLPT250/100 2 x 2.5 18.5 10 2.8 Blue 100

BLPT400/50 2 x 4 23 12 3.7 grey 50

BLPT600/25 2 x 6 26 14 4.8 Yellow 25

BLPT1000/10 2 x 10 26.5 14 6.4 Red 10

BLPT1600/10 2 x 16 31.5 14 8.3 Blue 10

D

L

L1

Cable Termination AccessoriesBootlace Ferrules

Page 46: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

44

Part No.

standard

Part No.

BellmouthNom

Cond.stud

size

DImeNsION AusTRALIAN TYPe

A B C D e f g

KL1.5-4 KL1.5-4Bm 1.5 4 2 8 1 4 5 7.5 18.5

KL1.5-5 KL1.5-5Bm 1.5 5 2 8 1 4 5 7.5 18.5

KL1.5-6 KL1.5-6Bm 1.5 6 2 10 0.8 4 6 7.5 19.5

KL2.5-4 KL2.5-4Bm 2.5 4 2.5 8 1 4 5 8 19

KL2.5-5 KL2.5-5Bm 2.5 5 2.5 10 0.8 5 6 8 20

KL2.5-6 KL2.5-6Bm 2.5 6 2.5 10 0.8 5 6 8 20

KL2.5-8 KL2.5-8Bm 2.5 8 2.5 11 0.7 6 9 8 26

KL4-5 KL4-5Bm 4 5 3.3 10 1 5 6 9 22

KL4-6 KL4-6Bm 4 6 3.3 10 1 5 6 9 22

KL4-8 KL4-8Bm 4 8 3.3 12 0.8 6 9 9 26

KL4-10 KL4-10Bm 4 10 3.3 15 0.8 8 11 9 32

KL6-5 KL6-5Bm 6 5 3.8 10 1.2 5 6 10 23

KL6-6 KL6-6Bm 6 6 3.8 12 1 6 9 10 27

KL6-8 KL6-8Bm 6 8 3.8 12 1 6 9 10 27

KL6-10 KL6-10Bm 6 10 3.8 15 0.8 8 11 10 32

KL10-5 KL10-5Bm 10 5 4.7 12 1.8 6 7 10 27

KL10-6 KL10-6Bm 10 6 4.7 12 1.8 6 7 10 27

KL10-8 KL10-8Bm 10 8 4.7 14 1.6 7 8 10 29

KL10-10 KL10-10Bm 10 10 4.7 15 1.5 8 10 10 32

KL10-12 KL10-12Bm 10 12 4.7 18 1 10 12 10 38

KL16-6 KL16-6Bm 16 6 5.5 11 2.4 7 9 19 39

KL16-8 KL16-8Bm 16 8 5.5 14 1.7 7 9 19 39

KL16-10 KL16-10Bm 16 10 5.5 16 1.5 8 10 19 41

KL16-12 KL16-12Bm 16 12 5.5 18 1.2 10 13 19 46

KL25-6 KL25-6Bm 25 6 7.1 13.5 2.4 7 9 21 41

KL25-8 KL25-8Bm 25 8 7.1 13.5 2.4 7 9 21 41

KL25-10 KL25-10Bm 25 10 7.1 16 1.9 9 10 21 44

KL25-12 KL25-12Bm 25 12 7.1 18 1.6 10 13 21 48

KL35-6 KL35-6Bm 35 6 8.4 16 3 9 10 21 45

KL35-8 KL35-8Bm 35 8 8.4 16 3 9 10 21 45

KL35-10 KL35-10Bm 35 10 8.4 185 2.6 9 10 21 45

KL35-12 KL35-12Bm 35 12 8.4 20 2.2 11 13 22 51

KL50-6 KL50-6Bm 50 6 9.5 18 3.3 8 10 22 46

KL50-8 KL50-8Bm 50 8 9.5 18 3.3 8 10 22 46

KL50-10 KL50-10Bm 50 10 9.5 18 3.3 8 10 22 46

KL50-12 KL50-12Bm 50 12 9.5 21 2.7 11 13 22 52

KL70-6 KL70-6Bm 70 6 11.3 21 3.5 11 13 24 54

KL70-8 KL70-8Bm 70 8 11.3 21 3.5 11 13 24 54

KL70-10 KL70-10Bm 70 10 11.3 21 3.5 11 13 24 54

KL70-12 KL70-12Bm 70 12 11.3 21 3.5 11 13 24 54

KL70-16 KL70-16Bm 70 16 11.3 26 3 14 16 24 61

KL95-8 KL95-8Bm 95 8 13.5 25 4 12 14 27 60

KL95-10 KL95-10Bm 95 10 13.5 25 4 12 14 27 60

KL95-12 KL95-12Bm 95 12 13.5 25 4 12 14 27 60

A

B

D E F

G

C

Cable Termination AccessoriesCopper Lugs

Page 47: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

45

Part No.

standard

Part No.

BellmouthNom

Cond.stud

size

DImeNsION AusTRALIAN TYPe

A B C D e f g

KL95-16 KL95-16Bm 95 16 13.5 25 3.5 14 16 27 61

KL120-8 KL120-8Bm 120 8 15.6 30 5 12 14 30 64

KL120-10 KL120-10Bm 120 10 15.6 30 5 12 14 30 64

KL120-12 KL120-12Bm 120 12 15.6 30 5 12 14 30 64

KL120-16 KL120-16Bm 120 16 15.6 30 5 16 16 30 72

KL150-10 KL150-10Bm 150 10 16.7 32 5.8 16 16 30 71

KL150-12 KL150-12Bm 150 12 16.7 32 5.8 18 18 30 75

KL150-16 KL150-16Bm 150 16 16.7 32 5.8 18 18 30 75

KL185-10 KL185-10Bm 185 10 18.4 36 5.8 16 16 32 74

KL185-12 KL185-12Bm 185 12 18.4 36 5.8 18 18 32 79

KL185-16 KL185-16Bm 185 16 18.4 36 5.8 18 18 32 79

KL240 KL240Bm 240 - 21.2 41 7 21 21 38 92

KL240-10 KL240-10Bm 240 10 21.2 41 7 21 21 38 92

KL240-12 KL240-12Bm 240 12 21.2 41 7 21 21 38 92

KL240-16 KL240-16Bm 240 16 21.2 41 7 21 21 38 92

KL300 KL300Bm 300 - 23.8 46 7.8 23 23 42 101

KL300-12 KL300-12Bm 300 12 23.8 46 7.8 23 23 42 101

KL300-16 KL300-16Bm 300 16 23.8 46 7.8 23 23 42 101

KL400 KL400Bm 400 - 26.8 50 8 24 24 44 107

KL500 KL500Bm 500 - 30 56 9 27 27 50 119

KL630 KL630Bm 630 - 34 64.4 11 32 32 58 139

Copper Crimp Links

Part No. Nom Cond. Overall Length I.D.

KC2.5 2.5 22.2 2.5

KC4 4 22.2 3.3

KC6 6 22.2 3.7

KC10 10 22.2 4.7

KC16 16 44.4 5.5

KC25 25 47.6 7.1

KC35 35 47.6 8.4

KC50 50 47.6 9.5

KC70 70 50.8 11

KC95 95 54 13.4

KC120 120 65.1 15.5

KC150 150 65.1 16.3

KC185 185 65.1 18.4

KC240 240 88.9 21.2

KC300 300 88.9 23.8

KC400 400 88.9 26.8

KC500 500 114.3 30

KC630 630 114.3 33.5

Cable Termination AccessoriesCopper Lugs

Part No.

standard

Part No.

BellmouthNom

Cond.stud

size

DImeNsION AusTRALIAN TYPe

A B C D e f g

KL1.5-4 KL1.5-4Bm 1.5 4 2 8 1 4 5 7.5 18.5

KL1.5-5 KL1.5-5Bm 1.5 5 2 8 1 4 5 7.5 18.5

KL1.5-6 KL1.5-6Bm 1.5 6 2 10 0.8 4 6 7.5 19.5

KL2.5-4 KL2.5-4Bm 2.5 4 2.5 8 1 4 5 8 19

KL2.5-5 KL2.5-5Bm 2.5 5 2.5 10 0.8 5 6 8 20

KL2.5-6 KL2.5-6Bm 2.5 6 2.5 10 0.8 5 6 8 20

KL2.5-8 KL2.5-8Bm 2.5 8 2.5 11 0.7 6 9 8 26

KL4-5 KL4-5Bm 4 5 3.3 10 1 5 6 9 22

KL4-6 KL4-6Bm 4 6 3.3 10 1 5 6 9 22

KL4-8 KL4-8Bm 4 8 3.3 12 0.8 6 9 9 26

KL4-10 KL4-10Bm 4 10 3.3 15 0.8 8 11 9 32

KL6-5 KL6-5Bm 6 5 3.8 10 1.2 5 6 10 23

KL6-6 KL6-6Bm 6 6 3.8 12 1 6 9 10 27

KL6-8 KL6-8Bm 6 8 3.8 12 1 6 9 10 27

KL6-10 KL6-10Bm 6 10 3.8 15 0.8 8 11 10 32

KL10-5 KL10-5Bm 10 5 4.7 12 1.8 6 7 10 27

KL10-6 KL10-6Bm 10 6 4.7 12 1.8 6 7 10 27

KL10-8 KL10-8Bm 10 8 4.7 14 1.6 7 8 10 29

KL10-10 KL10-10Bm 10 10 4.7 15 1.5 8 10 10 32

KL10-12 KL10-12Bm 10 12 4.7 18 1 10 12 10 38

KL16-6 KL16-6Bm 16 6 5.5 11 2.4 7 9 19 39

KL16-8 KL16-8Bm 16 8 5.5 14 1.7 7 9 19 39

KL16-10 KL16-10Bm 16 10 5.5 16 1.5 8 10 19 41

KL16-12 KL16-12Bm 16 12 5.5 18 1.2 10 13 19 46

KL25-6 KL25-6Bm 25 6 7.1 13.5 2.4 7 9 21 41

KL25-8 KL25-8Bm 25 8 7.1 13.5 2.4 7 9 21 41

KL25-10 KL25-10Bm 25 10 7.1 16 1.9 9 10 21 44

KL25-12 KL25-12Bm 25 12 7.1 18 1.6 10 13 21 48

KL35-6 KL35-6Bm 35 6 8.4 16 3 9 10 21 45

KL35-8 KL35-8Bm 35 8 8.4 16 3 9 10 21 45

KL35-10 KL35-10Bm 35 10 8.4 185 2.6 9 10 21 45

KL35-12 KL35-12Bm 35 12 8.4 20 2.2 11 13 22 51

KL50-6 KL50-6Bm 50 6 9.5 18 3.3 8 10 22 46

KL50-8 KL50-8Bm 50 8 9.5 18 3.3 8 10 22 46

KL50-10 KL50-10Bm 50 10 9.5 18 3.3 8 10 22 46

KL50-12 KL50-12Bm 50 12 9.5 21 2.7 11 13 22 52

KL70-6 KL70-6Bm 70 6 11.3 21 3.5 11 13 24 54

KL70-8 KL70-8Bm 70 8 11.3 21 3.5 11 13 24 54

KL70-10 KL70-10Bm 70 10 11.3 21 3.5 11 13 24 54

KL70-12 KL70-12Bm 70 12 11.3 21 3.5 11 13 24 54

KL70-16 KL70-16Bm 70 16 11.3 26 3 14 16 24 61

KL95-8 KL95-8Bm 95 8 13.5 25 4 12 14 27 60

KL95-10 KL95-10Bm 95 10 13.5 25 4 12 14 27 60

KL95-12 KL95-12Bm 95 12 13.5 25 4 12 14 27 60

Page 48: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

ww

w.k

abex

.com

.au

• P

h: 0

2 9

67

5 7

61

6

46

KABEX KM65 Cable Markers are a versatile cable marking system for labelling small and large cables, conduits and pipes. Cable Markers with their unique oval shape can slip directly over small cables before termination or slip onto Carrier Strips to suit larger cable or cable bundles.

Cable markersMade of the finest soft grade, strong, durable PVC . KABEX KM65 Cable Markers are resistant to oil, grease and other material erosion.

Part Number marking suitable

Range

(mm)

Width

(mm)

Pack Qty

Km65-A A 3.5 - 7 5 500

Km65-B B 3.5 - 7 5 500

Km65-C C 3.5 - 7 5 500

Km65-D D 3.5 - 7 5 500

Km65-e e 3.5 - 7 5 500

Km65-f f 3.5 - 7 5 500

Km65-g g 3.5 - 7 5 500

Km65-h h 3.5 - 7 5 500

Km65-I I 3.5 - 7 5 500

Km65-J J 3.5 - 7 5 500

Km65-K K 3.5 - 7 5 500

Km65-L L 3.5 - 7 5 500

Km65-m m 3.5 - 7 5 500

Km65-N N 3.5 - 7 5 500

Km65-O O 3.5 - 7 5 500

Km65-P P 3.5 - 7 5 500

Km65-Q Q 3.5 - 7 5 500

Km65-R R 3.5 - 7 5 500

Km65-s s 3.5 - 7 5 500

Km65-T T 3.5 - 7 5 500

Km65-u u 3.5 - 7 5 500

Km65-V V 3.5 - 7 5 500

Part Number marking suitable

Range

(mm)

Width

(mm)

Pack Qty

Km65-W W 3.5 - 7 5 500

Km65-X X 3.5 - 7 5 500

Km65-Y Y 3.5 - 7 5 500

Km65-Z Z 3.5 - 7 5 500

Km65-0 0 3.5 - 7 5 500

Km65-1 1 3.5 - 7 5 500

Km65-2 2 3.5 - 7 5 500

Km65-3 3 3.5 - 7 5 500

Km65-4 4 3.5 - 7 5 500

Km65-5 5 3.5 - 7 5 500

Km65-6 6 3.5 - 7 5 500

Km65-7 7 3.5 - 7 5 500

Km65-8 8 3.5 - 7 5 500

Km65-9 9 3.5 - 7 5 500

Km65-11 / 3.5 - 7 5 500

Km65-12 + 3.5 - 7 5 500

Km65-13 - 3.5 - 7 5 500

Km65-14 . 3.5 - 7 5 500

Km65-16 eARTh 3.5 - 7 5 500

Km65-17 BLANK 3.5 - 7 5 500

Carrier stripsUL Approved Nylon 66 (Black) with flammability rating 94V-2. Cable tie fastening holes to accomodate marker pieces for easy identification of cable runs.

Part Number Dimensions (mm) Capacity

(max. Km65

markers)

Pack Qty

L W TKm65-65 65 9 6.7 9 pcs 100

Km65-100 100 9 6.95 16 pcs 100

Km65-135 135 9 7 23 pcs 100

Km65-135L 135 9 13 21 pcs 100

L

W

T

Cable Termination AccessoriesKM65 Cable Markers

Page 49: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

Thread Dimensions

American NPT

Thread

Approx Hole Size

Protection against solids Protection against liquids

1st Figure Protection 2nd Figure Protection

0 No specific protection 0 No specific protection

1 Protected against solid objects equal

to or greater than 50mm diameter

(eg. accidental contact with hand)

1 Protected against drops of water falling

vertically

2 Protected against solid objects equal

to or greater than 12.5mm diameter

(eg. contact with finger)

2 Protected against drops of water falling at

up to 15 degrees from the vertical

3 Protected against solid objects equal

to or greater than 2.5mm diameter

(eg. tools and wires)

3 Protected against spraying water at up to

60 degrees from the vertical

4 Protected against solid objects equal

to or greater than 1mm diameter (eg.

fine tools and wires)

4 Protected against splashing water from all

directions

5 Protected against quantities of dust

that could intefere with satisfactory

operation

5 Protected against jets of water from all

directions

6 Completely protected against dust 6 Protected against jets of water of similar

force to heavy seas

Example:Identifying letters IP65Completely protected against dust,Protected against jets of water from all directions

7 Protected against the effects of tempory

immersion

8 Protected against the effects of

continuous immersion

American NPT

Thread

Approx

Hole Size

NPT 1/2" 22mm

NPT 3/4" 26mm

NPT 1" 34mm

NPT 1-1/4" 43mm

NPT 1-1/2" 50mm

NPT 2" 62mm

NPT 2-1/2" 74mm

NPT 3" 90mm

NPT 3-1/2" 102mm

NPT 4" 114mm

German

PG Thread

Approx Hole

Size

PG7 13mm

PG9 15.7mm

PG11 19mm

PG13.5 21mm

PG16 23mm

PG21 28.8mm

PG29 37.5mm

PG36 47.5mm

PG42 54.5mm

PG48 59.8mm

ISO

Metric Thread

Approx Hole

Size

M12 12.5mm

M16 16.5mm

M20 20.5mm

M25 25.5mm

M32 32.5mm

M40 40.5mm

M50 50.5mm

M63 64.0mm

International Protection Ratings

Page 50: ProduCt Catalogue -  · PDF fileProduCt Catalogue 2011 Ver 1.1. ... Instrumentation Cable 2 - 10 ... Hi Temperature 24 - 28 Halogen Free Single Core 125Deg Flexible 24

9/155 Glendenning Rd, Glendenning NSW 2761Ph: 02 9675 7616 | Fax: 02 9675 6992

www.kabex.com.au