ProCash 2050xe ENG

download ProCash 2050xe ENG

of 158

Transcript of ProCash 2050xe ENG

  • 7/24/2019 ProCash 2050xe ENG

    1/158

    Installation Guide

    ProCash 2050xe

    Self-S

    ervice

    S y s t em s

  • 7/24/2019 ProCash 2050xe ENG

    2/158

    Questions and suggestions

    ProCash 2050xe - Installation Guide 017500583

    Do you have ...

    ... any questions or suggestions regarding ... any technical questions or problems?this manual?

    Please contact the following address giving Please contact the Wincor Nixdorfthe order number of this manual in your Customer Care Center:message:

    E-mail:[email protected]:Wincor Nixdorf International GmbHHandbuchredaktion BD P34

    33094 PaderbornGermany

    Fax: +49 (0) 52 51 693-62 09

    E-mail:[email protected]

  • 7/24/2019 ProCash 2050xe ENG

    3/158

    ProCash 2050xe

    Installation Guide

    Edition August 2003

  • 7/24/2019 ProCash 2050xe ENG

    4/158

    Copyright Information and trademarks

    ProCash 2050xe - Installation Guide 017500583

    Wincor Nixdorf International GmbH 2003

    All rights, including rights of translation andrights of reproduction by reprinting, copyingor similar methods, even of parts, are

    reserved.Any violations give rise to a claim fordamages.

    All rights, including rights created by patentgrants or registration of a utility model ordesign, are reserved. Delivery subject toavailability; right of technical modificationsreserved.

    All names of hardware and software

    products mentioned in this manual aretrade names and/or trademarks of theirrespective manufacturers.

    This manual wasproduced using papertreated with chlorine-freebleach.

  • 7/24/2019 ProCash 2050xe ENG

    5/158

    01750058390 B ProCash 2050xe - Installation Guide

    Contents

    Introduction ................................................................................................................Symbols used in this guide...........................................................................................Important safety precautions .......................................................................................

    Installation notes ....................................................................................................General safety precautions .....................................................................................

    Abbreviations................................................................................................................

    Planning the Installation............................................................................................Device dimensions (tunnel width 35 mm - 1.38") ........................................................

    ProCash 2050xe with 4-cassette dispenser ...........................................................Device without illuminated signage ...................................................................Device with illuminated signage .........................................................................

    ProCash 2050xe with 6-cassette dispenser ............................................................Device without illuminated signage ...................................................................Device with illuminated signage .........................................................................

    Device dimensions (tunnel width 60 mm - 2.36") ........................................................ProCash 2050xe with 4-cassette dispenser ............................................................

    Device without illuminated signage ...................................................................Device with illuminated signage .........................................................................

    ProCash 2050xe with 6-cassette dispenser ............................................................Device without illuminated signage ...................................................................Device with illuminated signage .........................................................................

    Installation options........................................................................................................Device view (tunnel width 35 mm - 1.38") ...............................................................

    Without illuminated signage ..............................................................................With illuminated signage ....................................................................................

    Device view (tunnel width 60 mm - 2.36") ...............................................................Without illuminated signage ..............................................................................With illuminated signage ....................................................................................

    Wall opening 4-cassette dispenser .........................................................................Wall opening 6-cassette dispenser .........................................................................

    Vents ............................................................................................................................Storage if construction work is not yet complete .........................................................Space required for operation and maintenance ..........................................................Installation options........................................................................................................

    Installation options 4-cassette dispenser ................................................................Installation option 6-cassette dispenser ..................................................................

  • 7/24/2019 ProCash 2050xe ENG

    6/158

    Conte

    ProCash 2050xe - Installation Guide 017500583

    Installation site requirements............................................................................................Load carrying capacity.................................................................................................Protection from removal by force in compliance with EN and VdS guidelines............

    Installation frame 25 mm (0.98") ......................................................................................General.......................................................................................................................

    Securing the installation frames ..................................................................................Standard frame with hole dimensions ...................................................................Standard frame with cable lead-in dimensions ......................................................CEN frame with hole dimensions ...........................................................................CEN frame with cable lead-in dimensions .............................................................

    Calculating the base height ........................................................................................Installation frame 222 mm (8.74") ....................................................................................

    General.......................................................................................................................Securing the installation frames ..................................................................................

    Standard frame with hole dimensions ...................................................................Standard frame with cable lead-in dimensions ......................................................

    CEN frame with hole dimensions ...........................................................................CEN frame with cable lead-in dimensions .............................................................

    Height-adjustable installation rack ....................................................................................General.......................................................................................................................Securing the installation frames ..................................................................................

    Standard rack .........................................................................................................CEN rack ...............................................................................................................

    Finding the required installation rack ...........................................................................Tear-off sensor .................................................................................................................Drilling diagrams ..............................................................................................................

    Drilling diagram for 25 mm (0.98") installation frame ..................................................

    Drilling diagram for 222 mm (8.74") installation frame ................................................Drilling diagram for the installation rack ......................................................................Standard rack .........................................................................................................CEN rack ...............................................................................................................

    Power and data cables .....................................................................................................General information.....................................................................................................Power supply ...............................................................................................................Remote status indicator...............................................................................................

    Logo..................................................................................................................................Transport path requirements ............................................................................................

    Transport measurements for ProCash 2050xe ...........................................................

    Installation.......................................................................................................................Removing the packaging .................................................................................................Removing the shipping crate ............................................................................................

    General information.....................................................................................................Removing the shipping crate ......................................................................................

    Mounting sets ...................................................................................................................Mounting set 01750051579 for installation frame or installation rack .........................

  • 7/24/2019 ProCash 2050xe ENG

    7/158

    Contents

    01750058390 B ProCash 2050xe - Installation Guide

    Mounting set for safe on 25 mm (0.98") installation frame......................................Mounting set for safe on 222 mm (8.74") installation frame or installation rack ....

    Overview of installation options ....................................................................................Installation with 25 mm (0.98") installation frame ........................................................

    Installing the installation frame ................................................................................

    Mounting the device on the installation frame ........................................................Installation with 222 mm (8.74") installation frame .......................................................

    Installing the installation frame ................................................................................Mounting the device on the installation frame ........................................................

    Installation with height-adjustable installation rack ......................................................Preparing the installation rack .................................................................................

    Overview ...........................................................................................................Calculating the rack height.................................................................................Calculating the rack setting height .....................................................................

    Mounting the installation rack ..................................................................................Mounting the device on the installation rack ...........................................................

    Installing the tunnel frame ............................................................................................Start-up.........................................................................................................................

    Installing the Remote Status Indicator.....................................................................Delivery package ..........................................................................................................Installation ...................................................................................................................Shortening the cable ends............................................................................................

    Adapting the cable length at the relay end ..............................................................Adapting the cable length at the remote status indicator end .................................

    Appendix .....................................................................................................................

    Check list for installation preparations for self-service systems..................................General information.................................................................................................Preparations ...........................................................................................................

    Construction work ..............................................................................................Power and data cables......................................................................................Organizational preparations ..............................................................................Delivery and installation .....................................................................................Flooring materials on the path of transport ........................................................

    Notes concerning installation preparation ...............................................................Technical data .............................................................................................................

    General installation conditions ................................................................................

    Electrical characteristics of the supply network.................................................Device conditions ..............................................................................................Installation specifications ...................................................................................Environmental conditions ...................................................................................

    Compliance with standards and certifications ........................................................Standards met....................................................................................................Conformity..........................................................................................................Notes concerning radio interference suppression and electrical safety.............

  • 7/24/2019 ProCash 2050xe ENG

    8/158

    Conte

    ProCash 2050xe - Installation Guide 017500583

    FCC rules and Canadian standard ICES - 003 .....................................................Certification for data transmission.........................................................................

    Environmental protection.................................................................................................Environmentally friendly product design and development ........................................Saving energy.............................................................................................................

    Disposing of used consumables.................................................................................Labels on plastic case parts .......................................................................................Returning, recycling and disposing of used units and consumables ..........................Further information .....................................................................................................

    Scale drawings ................................................................................................................ProCash 2050xe with 4-cassette dispenser (tunnel width 35 mm (1.38")).................

    Device without illuminated signage .......................................................................Device with illuminated signage ............................................................................

    ProCash 2050xe with 4-cassette dispenser (tunnel width 60 mm (2.36")).................Device without illuminated signage .......................................................................Device with illuminated signage ............................................................................

    ProCash 2050xe with 6-cassette dispenser (tunnel width 35 mm (1.38")).................Device without illuminated signage .......................................................................Device with illuminated signage ............................................................................

    ProCash 2050xe with 6-cassette dispenser (tunnel width 60 mm (2.36")).................Device without illuminated signage .......................................................................Device with illuminated signage ............................................................................

    Space required for operation and maintenance .........................................................Tunnel width 35 mm (1.38") ..................................................................................Tunnel width 60 mm (2.36") ..................................................................................

    Transport ....................................................................................................................

  • 7/24/2019 ProCash 2050xe ENG

    9/158

    01750058390 B ProCash 2050xe - Installation Guide

    Introduction

    This installation guide provides all the information you require to plan and prepareinstallation and to set up the device.

    The ProCash 2050xe is available in the following versions:

    ProCash 2050xe with a tunnel width of 35 mm (1.38") ProCash 2050xe with a tunnel width of 60 mm (2.36")

    ProCash 2050xe without illuminated signage ProCash 2050xe with illuminated signage

    ProCash 2050xe with 4-cassette dispenser ProCash 2050xe with 6-cassette dispenser

    Symbols used in this guide

    Text following this mark represents an item in a list.

    " " Text in quotation marks contains references to other chapters or sections in thisdocument.

    Paragraphs following this symbol are actions to be performed in the specified ord

    Text following this symbol have to be given special attention in order to avoiddamage or injury.

    This symbol identifies paragraphs which contain general notes to facilitate uthe device and help avoid operating errors.

  • 7/24/2019 ProCash 2050xe ENG

    10/158

    Important safety precautions Introduc

    2 ProCash 2050xe - Installation Guide 017500583

    Important safety precautions

    Please read the following notes carefully before doing any work on the device.

    Installation notes

    When installing the device and/or doing any work on it, make sure that it isdisconnected from power.

    General safety precautions

    This device complies with the relevant safety regulations for information processingequipment.

    When moving the device from a cold to a warm environment, do not operate it for aleast two hours to prevent possible damage caused by condensation.

    Only use the original packaging material to transport the device.

    Note the warning and information labels on the device.

    The device is equipped with a safety-tested power cable, which must be connectedonly to a suitable grounded outlet.

    Only replace the fluorescent tubes of the logo / customer panel lighting when thedevice is turned off.

    Always hold the plug when removing the power cable. Never pull the cable itself.

    Install cables in such a way that they will not be stepped on or tripped over or damagor crushed in any way.

    Have damaged power cables replaced immediately.

    Make sure that there is always free access to the sockets used or to the electricalcircuit-breakers of the house installation.

  • 7/24/2019 ProCash 2050xe ENG

    11/158

    Introduction Important safety precau

    01750058390 B ProCash 2050xe - Installation Guide

    In case of an emergency (e.g. damaged cabinets, controls or power cables, liquidforeign objects in the device) take the following steps:

    Deactivate the device immediately by:

    Switching off the automatic circuit-breaker or removing the fuse inset from theholder in the distribution box of the building installation;Disconnecting the plug connector of the power supply cable from the groundesocket in the building installation;Switching off the ON/OFF switch on the power distributor.Interrupting the power connection between the UPS (uninterruptible power supand device (see section "General power interrupt" in the operating manual);

    Inform the customer service responsible for you.

    During a thunderstorm, data transmission lines must not be connected or

    disconnected.

    Always keep the device's vents free from obstruction to ensure proper air circulatand to prevent malfunctions resulting from overheating.

    Only use accessories and extension components that have been approved by usNonobservance can result in damage to the device or violations of regulationsconcerning safety, radio interference and ergonomical requirements.

    Note that there are only safety extra-low voltage circuits (SELV circuits) if you wanfeed voltage from an external source into prepared cables to install additionalelectronics (e.g. connection for an intruder alarm system).

    To clean the device only use cleaning agents approved by W incor Nixdorf InternaGmbH (see chapter "Appendix", section "Approved cleaning materials" in the opemanual).

  • 7/24/2019 ProCash 2050xe ENG

    12/158

    Important safety precautions Introduc

    4 ProCash 2050xe - Installation Guide 017500583

    Repairs

    Repair work may only be carried out by authorized personnel.

    Unauthorized opening of the device or repair work carried out improperly could

    result in considerable danger to the user.

    In case of noncompliance, W incor Nixdorf International GmbH excludes allliability.

    Lithium batteries

    There is danger of fire or explosion if the batteries are handled improperly. It istherefore important to note the following points:

    Avoid short circuits.Never recharge the battery.

    Avoid temperatures above 100 C.

    Do not try to open the battery by force.

    Do not allow the battery to come into contact with water or fire.

    Only replace it by the same or an equivalent type recommended by WincorNixdorf International GmbH (see chapter "Appendix", section "Consumables" inthe operating manual).

    Dispose of used batteries in compliance with national regulations and the

    manufacturer's specifications.

  • 7/24/2019 ProCash 2050xe ENG

    13/158

    Introduction Abbrevia

    01750058390 B ProCash 2050xe - Installation Guide

    Abbreviations

    CCDM Cheque / cash deposit module

    CCFL Cold-cathode fluorescent light

    CE Communaut Europenne(European Community) Declaration of Conformity

    CEN European Committee for Standardization

    CIM Card identification module

    CMD-V4 Cash media dispenser version 4

    CSA Canadian Standards Association

    DIN German Institute for Standardization

    DT Data transmission

    EC European Community

    EDM Encryption / decryption module

    EEC European Economic Community

    EMA Intruder alarm system

    EMC Electromagnetic compatibility

    EN European standard

    FCC Federal Communications Commission

    ICES Interference Causing Equipment Standards

    IEC International Electrotechnical Commission

    IP International protection

    ISO International Organization for Standardization

    L N PE Line neutral protective earthMM Modular marker of the ID card (evaluation by means of security

    modules like MM box or CIM 86)

    SELV Safety extra-low voltage

    TN network Power supply network in acc. with EN 60950

    UL Underwriters Laboratories

    UPS Uninterruptible power supply

    VdS Association of German Property Insurers

  • 7/24/2019 ProCash 2050xe ENG

    14/158

    Abbreviations Introduc

    6 ProCash 2050xe - Installation Guide 017500583

  • 7/24/2019 ProCash 2050xe ENG

    15/158

    01750058390 B ProCash 2050xe - Installation Guide

    Planning the Installation

    This chapter provides you with all the information you need to prepare the installation

    Device dimensions (tunnel width 35 mm - 1.38")

    All dimensions are specified in millimeters (inches). The views of the device

    not drawn to scale.

    All device edges have a radius of 3 mm (0.12").

    A front view, side view, top view, rear view and a view of the maintenance spon a scale of 1:20 can be found in the appendix.

  • 7/24/2019 ProCash 2050xe ENG

    16/158

    Device dimensions (tunnel width 35 mm - 1.38") Planning the Installa

    8 ProCash 2050xe - Installation Guide 017500583

    ProCash 2050xe with 4-cassette dispenser

    Device without illuminated signage

    15

    00(59.0

    6")

    13.5

    634 (24.96")

    500

    600 (23.62") 848 (33.39")

    1500(59.0

    6")

    1890(74.4

    1")

    885(34.8

    4")

    614(24.1

    7")

    668(26.3

    ")

    667(26.2

    6")

    658(25.9

    1")

    677(26.6

    5")

    1405

    (55.3

    1")

    72/43*

    1208 (47.56")

    1243 (48.94")

    215 (8.46")

    35(1.38")

    (1.69"/ 2.83" *)

    (0.53")

    (19.69")

    * Standard lock: 43 mm (1.69")Customer-specific lock: 72 mm (2.83")

  • 7/24/2019 ProCash 2050xe ENG

    17/158

    Planning the Installation Device dimensions (tunnel width 35 mm -

    01750058390 B ProCash 2050xe - Installation Guide

    Device with illuminated signage

    13.5

    634 (24.96")

    600 (23.62")

    500

    848 (33.39")

    1500(59.0

    6")

    1890(74.4

    1")

    885(34.8

    4")

    614(24.1

    7")

    668(26.3

    ")

    667(26.2

    6")

    658(25.9

    1")

    677(26.6

    5")

    72/43*

    1208 (47.56")

    1243 (48.94")

    215 (8.46")

    50 (1.97")

    35

    484 (19.06")

    1616(63.6

    2")

    (0.53")

    (19.69")

    (1.69" / 28.3" *)

    (1.38")

    * Standard lock: 43 mm (1.69")Customer-specific lock: 72 mm (2.83")

  • 7/24/2019 ProCash 2050xe ENG

    18/158

    Device dimensions (tunnel width 35 mm - 1.38") Planning the Installa

    10 ProCash 2050xe - Installation Guide 017500583

    ProCash 2050xe with 6-cassette dispenser

    Device without illuminated signage

    13.5

    634 (24.96")

    500

    600 (23.62")

    1760

    (69.2

    9")

    848 (33.39")

    1760(69

    .29")

    2150(84.6

    5")

    1145(45.0

    8")

    874(34.4

    1")

    928(36.5

    4")

    667(26.2

    6")

    918(36.1

    4")

    677(26.6

    5")

    1665(65.5

    5")

    72/43*

    1208 (47.56")

    1243 (48.94")

    215 (8.46")

    35

    (1.69" / 2.83" *)

    (0.53")

    (19.69")

    (1.38")

    * Standard lock: 43 mm (1.69")Customer-specific lock: 72 mm (2.83")

  • 7/24/2019 ProCash 2050xe ENG

    19/158

    Planning the Installation Device dimensions (tunnel width 35 mm -

    01750058390 B ProCash 2050xe - Installation Guide

    Device with illuminated signage

    13.5

    634 (24.96")

    600 (23.62")

    500

    484 (19.06")

    1876(73.8

    6")

    848 (33.39")

    1760(69.2

    9")

    2150(84.6

    5")

    1145(45.08")

    874(34.4

    1")

    928(36.5

    4")

    667(26.2

    6")

    918(36.1

    4")

    677(26.6

    5")

    1 8 7 6 ( 7 3 8 6 " )

    72/43*

    1208 (47.56")

    1243 (48.94")

    215 (8.46")

    50 (1.97")

    35(1.38")

    (1.69" / 2.83" *)

    (0.53")

    (19.69")

    * Standard lock: 43 mm (1.69")Customer-specific lock: 72 mm (2.83")

  • 7/24/2019 ProCash 2050xe ENG

    20/158

    Device dimensions (tunnel width 60 mm - 2.36") Planning the Installa

    12 ProCash 2050xe - Installation Guide 017500583

    Device dimensions (tunnel width 60 mm - 2.36")

    All dimensions are specified in millimeters (inches). The views of the device arnot drawn to scale.

    All device edges have a radius of 3 mm (0.12").

    A front view, side view, top view, rear view and a view of the maintenance spacon a scale of 1:20 can be found in the appendix.

  • 7/24/2019 ProCash 2050xe ENG

    21/158

    Planning the Installation Device dimensions (tunnel width 60 mm -

    01750058390 B ProCash 2050xe - Installation Guide

    ProCash 2050xe with 4-cassette dispenser

    Device without illuminated signage

    1500(59.0

    6")

    13.5

    634 (24.96")

    500

    600 (23.62") 848 (33.39")

    1500

    (59.0

    6")

    1890(74.4

    1")

    885(34.8

    4")

    614(24.1

    7")

    668(26.3

    ")

    6

    67(26.2

    6")

    658(25.9

    1")

    6

    77(26.6

    5")

    1 4 1 6 ( 5

    5 7 5 " )

    72/43*

    1183 (46.57")

    1243 (48.94")

    215 (8.46")

    60

    (2.36")

    (0.53")

    (1.69" / 2.83"*)

    (19.69")

    * Standard lock: 43 mm (1.69")Customer-specific lock: 72 mm (2.83")

  • 7/24/2019 ProCash 2050xe ENG

    22/158

    Device dimensions (tunnel width 60 mm - 2.36") Planning the Installa

    14 ProCash 2050xe - Installation Guide 017500583

    Device with illuminated signage

    13.5

    634 (24.96")

    600 (23.62")

    500

    484 (19.06")

    1630(64.1

    7")

    848 (33.39")

    1500(59.0

    6")

    1890(74.4

    1")

    885(34.8

    4")

    614(24.1

    7")

    668(26.3

    ")

    667(26.2

    6")

    658(25.9

    1")

    677(26.6

    5")

    1630(64.1

    7")

    72/43*

    1183 (46.57")

    1243 (48.94")

    215 (8.46")

    60(2.36")

    (1.69" / 2.83" *)

    (0.53")

    (19.69")

    * Standard lock: 43 mm (1.69")Customer-specific lock: 72 mm (2.83")

  • 7/24/2019 ProCash 2050xe ENG

    23/158

    Planning the Installation Device dimensions (tunnel width 60 mm -

    01750058390 B ProCash 2050xe - Installation Guide

    ProCash 2050xe with 6-cassette dispenser

    Device without illuminated signage

    1145(45.0

    8")

    1760(69.2

    9")

    2150(84.6

    5")

    215 (8.46")

    1687

    (66.42

    ")

    874

    (34.4

    1")

    928(36.5

    4")

    918

    (36.1

    4")

    600 (23.62") 848 (33.39")

    1183 (46.57")

    60 (2.36")

    677(26.6

    5")

    667

    (26.2

    6")

    43 / 72 *

    13.5

    634 (24.96")

    500

    (1.69" / 2.83" *)

    (19.69")

    (0.53")

    * Standard lock: 43 mm (1.69")Customer-specific lock: 72 mm (2.83")

  • 7/24/2019 ProCash 2050xe ENG

    24/158

    Device dimensions (tunnel width 60 mm - 2.36") Planning the Installa

    16 ProCash 2050xe - Installation Guide 017500583

    Device with illuminated signage

    13.5

    634 (24.96")

    500

    1145(45.0

    8")

    1760

    (69.2

    9")

    2150

    (84.6

    5")

    215 (8.46")

    1891

    (74.4

    5")

    677

    (26.6

    5")

    928(36.5

    4")

    667(26.2

    6")

    918(36.1

    4")

    1

    891(74.4

    5")

    874

    (34.4

    1")

    848 (33.39")

    60

    75 (2.95")

    1183 (46.57")

    600 (23.62")

    484 (19.06")

    43 / 72 *

    (2.36")

    (1.69" / 2.83" *)

    (0.53")

    (19.69")

    * Standard lock: 43 mm (1.69")Customer-specific lock: 72 mm (2.83")

  • 7/24/2019 ProCash 2050xe ENG

    25/158

    Planning the Installation Installation op

    01750058390 B ProCash 2050xe - Installation Guide

    Installation options

    The ProCash 2050xe can only be installed through a wall opening.

    The following table gives a list of installation options depending on the floor heights ocustomer panel side and on the device side.

    The installation options apply to the 35 mm (1.38") as well as the 60 mm (2.36") tunnwidth.

    Installation options Same floorheight

    Different fheight

    Installation with 25 mm (0.98") installation frame

    (ProCash 2050xe with 6-cassette dispenser) yes no

    Installation with 25 mm (0.98") installation frameon a concrete base yes yes

    Installation with 222 mm (8.74") installation frame yes no

    Installation with height-adjustable installation rack no yes

    Observe the necessary operation and maintenance space for the various typinstallation (see section "Space required for operation and maintenance").

  • 7/24/2019 ProCash 2050xe ENG

    26/158

    Installation options Planning the Installa

    18 ProCash 2050xe - Installation Guide 017500583

    Device view (tunnel width 35 mm - 1.38")

    Without illuminated signage

  • 7/24/2019 ProCash 2050xe ENG

    27/158

    Planning the Installation Installation op

    01750058390 B ProCash 2050xe - Installation Guide

    With illuminated signage

  • 7/24/2019 ProCash 2050xe ENG

    28/158

    Installation options Planning the Installa

    20 ProCash 2050xe - Installation Guide 017500583

    Device view (tunnel width 60 mm - 2.36")

    Without illuminated signage

  • 7/24/2019 ProCash 2050xe ENG

    29/158

    Planning the Installation Installation op

    01750058390 B ProCash 2050xe - Installation Guide

    With illuminated signage

  • 7/24/2019 ProCash 2050xe ENG

    30/158

    Installation options Planning the Installa

    22 ProCash 2050xe - Installation Guide 017500583

    Wall opening 4-cassette dispenser

    The specified measurements for the wall opening (device version with 4-cassedispenser) are the ergonomic measurements which are measured at the outsid

    of the wall.

    1 Outside wall 2 Inside wall (device side)

    W *: Wall thickness for 35 mm (1.38") tunnel width: max. 360 mm (14.17")Wall thickness for 60 mm (2.36") tunnel width: max. 335 mm (13.19")

  • 7/24/2019 ProCash 2050xe ENG

    31/158

    Planning the Installation Installation op

    01750058390 B ProCash 2050xe - Installation Guide

    Wall opening 6-cassette dispenser

    The specified measurements for the wall opening (device version with 6-casdispenser) are the ergonomic measurements which are measured at the out

    of the wall.

    1 Outside wall 2 Inside wall (device side)

    W *: Wall thickness for 35 mm (1.38") tunnel width: max. 360 mm (14.17")Wall thickness for 60 mm (2.36") tunnel width: max. 335 mm (13.19")

  • 7/24/2019 ProCash 2050xe ENG

    32/158

    Vents Planning the Installa

    24 ProCash 2050xe - Installation Guide 017500583

    Vents

    The device features forced air ventilation on the right side of the top part by means of abuilt-in fan. Additionally, there are vents on the left and on the rear of the top part. Make

    sure that the distance between these vents and the wall is always at least 50 mm (1.97

    1

    1 Vents

    Storage if construction work is not yet complete

    If the system is installed while interior construction is still underway, be sure toprotect it against dirt and dust from the construction. You may use the plasticpacking of the system for this purpose.

  • 7/24/2019 ProCash 2050xe ENG

    33/158

    Planning the Installation Space required for operation and mainte

    01750058390 B ProCash 2050xe - Installation Guide

    Space required for operation and maintenance

    The following two illustrations show the necessary operation and maintenance space35 mm (1.38") tunnel width and for 60 mm (2.36") tunnel width.

    Ventilation space

    Additional operation and maintenance space, right or left

    Operation and maintenance space

    Additional space required for the installation (for reaching the fastening scin the safe).

    1 Wall

  • 7/24/2019 ProCash 2050xe ENG

    34/158

    Space required for operation and maintenance Planning the Installa

    26 ProCash 2050xe - Installation Guide 017500583

    Tunnel width 35 mm (1.38")

    1

    150(5.91")

    350(13.78")

    700(27.56")

    850(33.4

    6")

    848(33.3

    9")

    780(30.7

    1")

    620(24.4

    1")

    1100(43.31")

    350

    (13.78")

    980(38.5

    8")

    50(1.97")13.5

    (0.53")

    50(1.97")

    350(13.78")

  • 7/24/2019 ProCash 2050xe ENG

    35/158

    Planning the Installation Space required for operation and mainte

    01750058390 B ProCash 2050xe - Installation Guide

    Tunnel width 60 mm (2.36")

    875(34.4

    5")

    1100(43.31")

    350

    (13.78")

    150(5.91")

    620(24.4

    1")

    780(30.7

    1")

    980(38.5

    8")

    848(33.3

    9")

    50(1.97")13.5

    (0.53")

    50(1.97")

    350(13.78")

    700(27.56")

    350(13.78")

  • 7/24/2019 ProCash 2050xe ENG

    36/158

    Installation options Planning the Installa

    28 ProCash 2050xe - Installation Guide 017500583

    Installation options

    The installation options are described for the ProCash 2050xe with 35 mm (1.38") tunnwidth by way of example. The specified heights also apply to the ProCash 2050xe vers

    with 60 mm (2.36") tunnel width.

    Installation options 4-cassette dispenser

    The ProCash 2050xe can be installed through the wall with floors the same height on thinside and on the outside, with a higher floor on the outside or with a higher floor on theinside.

    Possible versions

    The illustration below shows a higher floor level on the outside. The descriptionalso apply if the floor level is higher on the inside and if the floor is on the samelevel on the inside and outside.

    The three different versions I (height-adjustable installation rack), II (222 mm(8.74") installation frame) and III (25 mm (0.98") installation frame) are shown othe right side in the following picture.

  • 7/24/2019 ProCash 2050xe ENG

    37/158

    Planning the Installation Installation op

    01750058390 B ProCash 2050xe - Installation Guide

    1

    2

    2

    3

    4

    615(24.2

    1")

    6

    48

    710(27.9

    5")

    870(34.2

    5")

    935*(36.81"*)

    1890(74.4

    1")

    x1

    x2

    W**

    I:

    1

    3

    x3

    x4

    III :

    1

    3

    x5

    25

    II:

    1

    3

    222

    (8.7

    4")

    (25.5

    1")

    (0.9

    8")

    1 Device 8 Installation frame 25 mm (0.98")

    2 Wall 9 Concrete base provided by customer

    3 Floor inside X1 Height of wall opening (Xwall)

    4 Floor outside X2 Adjustable height (Xheight )

    5 Installation rack, upper part X3 Adjustable height of installation rack

    6 Installation rack, lower part (Xvariable)

    7 Installation frame 222 mm X4 Rack height (Xrack)(8.74") X5 Height of base (Xbase)

    * Height of customer panel keypad

    W ** Wall thickness for 35 mm (1.38") tunnel width: max. 360 mm (14.17")Wall thickness for 60 mm (2.36") tunnel width: max. 335 mm (13.19")

  • 7/24/2019 ProCash 2050xe ENG

    38/158

    Installation options Planning the Installa

    30 ProCash 2050xe - Installation Guide 017500583

    Version I: The height-adjustable installation rack is needed if the ProCash 2050xe to be installed on the floor and the inside and outside floor heights aredifferent (see section "Height-adjustable installation rack").

    Version II: The 222 mm (8.74") installation frame is needed if the ProCash 2050xe to be installed on the floor through the specified wall opening and the flooheight is the same inside and outside (see section "Wall opening 4cassette dispenser").

    Version III: As an alternative, the device can be installed using the 25 mm (0.98")installation frame on a fixed base supplied by the customer (see thesection "Installation frame 25 mm (0.98")) if floor heights are the same odifferent.

    Not any difference in floor level can be compensated by the installation versiondescribed. Therefore, the following limit values apply for XWall:

    CEN / UL safeOption I: min. 778 mm (30.63"), max. 968 mm (38.11")Option III: min. 673 mm (26.5")

  • 7/24/2019 ProCash 2050xe ENG

    39/158

    Planning the Installation Installation op

    01750058390 B ProCash 2050xe - Installation Guide

    Installation option 6-cassette dispenser

    Standard installation of the ProCash 2050xe with the same floor height on thinside and the outside is with the 25 mm (0.98") installation frame.

    1 2

    3 4

    615(24.2

    1")

    908(35.7

    5")

    710(27.9

    5")

    933(36.7

    3")

    988*(38.9

    "*)

    2150(84.6

    5")

    W**

    5

    1 Device 4 Floor outside

    2 Wall 5 Installation frame 25 mm (0.98")

    3 Floor inside

    * Height of customer panel keypad

    W ** Wall thickness for 35 mm (1.38") tunnel width: max. 360 mm (14.17")Wall thickness for 60 mm (2.36") tunnel width: max. 335 mm (13.19")

  • 7/24/2019 ProCash 2050xe ENG

    40/158

    Installation site requirements Planning the Installa

    32 ProCash 2050xe - Installation Guide 017500583

    Installation site requirements

    The installation area (floor or fixed base) must be horizontal. Any differences in floorheight in the installation area must be leveled out with rustproof shims, for example. Th

    is not part of the installation procedure, but must be done by a contractor.

    When choosing the installation site, make sure that

    bright ceiling light, light reflections and direct sunlight shining on the screen areavoided,

    the requirements concerning ambient conditions can be met (see chapter "Appendixsection "Technical data"),

    existing underfloor heating, energy and/or communication cables, etc., are notdamaged when drilling the mounting holes.

    If necessary, appropriate arrangements must be made.

    Load carrying capacity

    Ensure that the installation site has the required load-carrying capacity. You will find therelevant device weight in the section "Installation specifications" in the chapter "Append

  • 7/24/2019 ProCash 2050xe ENG

    41/158

    Planning the Installation Installation site requirem

    01750058390 B ProCash 2050xe - Installation Guide

    Protection from removal by force in compliance with EN and VdSguidelines

    In accordance with the applicable guidelines VdS 2527, VdS 2527-S1, EN 1

    and EN 1143 - 1 prAl safe and installation frame or rack form a unit.For this reason CEN safes may only be mounted with the certified and approinstallation frames or installation racks.

    The device must be screwed to the load-bearing substructure of the installation site mounted on a suitable base.

    Using the prescribed mounting materials, the following values relating to resistance tremoval of the safe from the installation frame are reached:

    Resistance level Minimum force required

    III 50 kN

    IV, V 100 kN

    The operator must provide a suitable base to protect it from removal by force. Werecommend reinforced concrete B35 (EN206 C30/37) or a higher-quality concrete.

  • 7/24/2019 ProCash 2050xe ENG

    42/158

    Installation frame 25 mm (0.98") Planning the Installa

    34 ProCash 2050xe - Installation Guide 017500583

    Installation frame 25 mm (0.98")

    General

    The 25 mm (0.98") installation frame has to be used if you want to install the ProCash2050xe with 4-cassette dispenser on a base (provided by customer) or if you want toinstall the ProCash 2050xe with 6-cassette dispenser on the floor.

    The installation frame can be either a standard installation frame or a CEN frame(identified by the 'CEN' sticker).

    The installation frame is secured to the base at the attachment points (see sections"Drilling diagram for 25 mm (0.98") installation frame"). Then the device is screwed to tinstallation frame.

    Openings which are not used have to be closed by putting in the filling pieces.

    For mounting material see section "Mounting sets" in the chapter "Installation".

    Securing the installation frames

    How the installation frame is secured depends on the resistance level (UL, CEN III or

    CEN IV/V) of the safe. The label showing the resistance level is located on the inside othe safe door.

    For a safe with resistance level III (CEN III) and UL, it is mandatory to secure theinstallation frame at the positions marked 2 withfourscrews.Positions 3 serve as alternative attachment points (see next illustrations).

    For a safe with resistance level IV/V (CEN IV/V), it is mandatory to secure the CEN framto the positions marked 2 and 3 with eightscrews (see next illustrations).

  • 7/24/2019 ProCash 2050xe ENG

    43/158

    Planning the Installation Installation frame 25 mm (

    01750058390 B ProCash 2050xe - Installation Guide

    Standard frame with hole dimensions

    104(4.09")

    2

    3

    2

    1

    4

    1

    3

    179(7.05")

    147

    (5.7

    9")

    185(7.2

    8")

    275(10.8

    3")

    575(22.6

    4")

    665(26.1

    8")

    687(27.0

    5")

    8

    2(33.1

    5")

    468.5(18.44")479(18.86")

    539(21.22")594(23.39")

    5

    6

    1 Attachment points of CEN / UL safe 4 Attachment point of tear-off se

    2 Attachment points of installation frame 5 Customer panel side3 Alternative attachment points 6 This side must always point

    of installation frame with CEN / UL safe to the side with the safe door

    on the standard frame

  • 7/24/2019 ProCash 2050xe ENG

    44/158

    Installation frame 25 mm (0.98") Planning the Installa

    36 ProCash 2050xe - Installation Guide 017500583

    Standard frame with cable lead-in dimensions

    222.5(8.76")

    344(13.54")

    390(15.35")

    1

    2

    3

    4

    420.5(16.56")

    35(1.3

    8")

    53.5

    (2.1

    1")

    111.5

    (4.3

    9")

    7

    6.5

    (30.5

    ")

    467.5(18.41")

    482.5(19.00")

    528.5(20.81")

    5

    6

    3

    1 Filling piece 4 Area for cables2 Cable feed opening 5 Customer panel side

    3 Cable exit opening underneath 6 This side must always point

    installation frame to the side with the safe door

  • 7/24/2019 ProCash 2050xe ENG

    45/158

    Planning the Installation Installation frame 25 mm (

    01750058390 B ProCash 2050xe - Installation Guide

    CEN frame with hole dimensions

    104(4.09")

    2

    3

    2

    1

    4

    1

    3

    179(7.05")

    147

    (5.7

    9")

    185(7.2

    8")

    275(10.8

    3")

    575(22.6

    4")

    665(26.1

    8")

    687(27.0

    5")

    8

    2(33.1

    5")

    468.5(18.44")479(18.86")

    539(21.22")594(23.39")

    5

    6

    1 Attachment points of CEN safe 4 Attachment point of tear-off se

    2 Attachment points of installation frame 5 Customer panel side3 Additional attachment points for 6 This side must always point

    CEN IV/V safe or alternative to the side with the safe door

    attachment points for CEN III

  • 7/24/2019 ProCash 2050xe ENG

    46/158

    Installation frame 25 mm (0.98") Planning the Installa

    38 ProCash 2050xe - Installation Guide 017500583

    CEN frame with cable lead-in dimensions

    1

    2

    3

    4

    5

    2

    222.5(8.76")

    420.5(16.56")

    467.5(18.41")

    482.5(19.00")

    528.5(20.81")

    35(1.3

    8")

    53.5

    (2.1

    1")

    111.5

    (4.3

    9")

    6.5

    (30.5

    ")

    344(13.54")

    390(15.35")

    1 Filling piece 4 Customer panel side2 Cable exit opening underneath 5 This side must always point

    installation frame to the side with the safe door

    3 Area for cables

  • 7/24/2019 ProCash 2050xe ENG

    47/158

    Planning the Installation Installation frame 25 mm (

    01750058390 B ProCash 2050xe - Installation Guide

    Calculating the base height

    If you want to set the ProCash 2050xe on a concrete base, calculate the base heighusing the following formula (see also the illustration in the section "Installation option

    cassette dispenser"):

    Xbase= Xwall 648 mm (25.51") 25 mm (0.98")(installation frame)

  • 7/24/2019 ProCash 2050xe ENG

    48/158

    Installation frame 222 mm (8.74") Planning the Installa

    40 ProCash 2050xe - Installation Guide 017500583

    Installation frame 222 mm (8.74")

    General

    The 222 mm (8.74") installation frame has to be used if you want to install the ProCash2050xe with 4cassette dispenser in the specified wall opening and with the same floorheight on both sides of the wall.

    The installation frame can be either a standard installation frame or a CEN frame(identified by the 'CEN' sticker).

    The installation frame is secured to the floor at the attachment points (see sections"Drilling diagram for 222 mm (8.74") installation frame"). Then the device is screwed tothe installation frame.

    Openings which are not used have to be closed by putting in the filling pieces.

    For mounting material see section "Mounting sets" in the chapter "Installation".

    Securing the installation frames

    How the installation frame is secured depends on the resistance level (UL, CEN III or

    CEN IV/V) of the safe. The label showing the resistance level is located on the inside othe safe door.

    For a safe with resistance level III (CEN III) and UL, it is mandatory to secure theinstallation frame at the positions marked 2 withfourscrews.Positions 3 serve as alternative attachment points (see next illustrations).

    For a safe with resistance level IV/V (CEN IV/V), it is mandatory to secure the CEN framto the positions marked 2 and 3 with eightscrews (see next illustrations).

  • 7/24/2019 ProCash 2050xe ENG

    49/158

    Planning the Installation Installation frame 222 mm (

    01750058390 B ProCash 2050xe - Installation Guide

    Standard frame with hole dimensions

    2

    3

    3

    21

    4

    1

    237(9.33")

    179(7.05")

    147

    (5.7

    9")

    194(7.6

    4")

    274(10.7

    9")

    599(23.5

    8")

    679(26.7

    3")

    687(27.0

    5")

    842(33.1

    5")

    469(18.46")481(18.94")

    539(21.22")594(23.39")

    5

    6

    1 Attachment points of CEN / UL safe 4 Attachment point of tear-off se

    2 Attachment points of installation frame 5 Customer panel side3 Alternative attachment points 6 This side must always point

    of installation frame with CEN / UL safe to the side with the safe door

    on the standard frame

  • 7/24/2019 ProCash 2050xe ENG

    50/158

    Installation frame 222 mm (8.74") Planning the Installa

    42 ProCash 2050xe - Installation Guide 017500583

    Standard frame with cable lead-in dimensions

    38.5

    (1.5

    2")

    55(2.1

    7")

    382(15.0

    3")

    462(18.1

    9")

    803(31.6

    1")

    483.7(19.04")

    530.3(20.88")

    55

    (2.17")

    151(5.94")

    265(10.43")

    453(17.83")

    1

    1

    2

    3

    3

    3

    4

    2

    5

    6

    1 Filling piece 4 Area for cables2 Cable feed opening 5 Customer panel side

    3 Cable exit opening underneath 6 This side must always point

    installation frame to the side with the safe door

  • 7/24/2019 ProCash 2050xe ENG

    51/158

    Planning the Installation Installation frame 222 mm (

    01750058390 B ProCash 2050xe - Installation Guide

    CEN frame with hole dimensions

    2

    3

    3

    2

    1

    4

    1

    5

    6

    237(9.33")

    179(7.05")

    469(18.46")481(18.94")

    539(21.22")

    594(23.39")

    147

    (5.7

    9")

    194(7.6

    4")

    274(10.7

    9")

    599(23.5

    8")

    679(26.7

    3")

    687(27.0

    5")

    8

    2(33.1

    5")

    1 Attachment points of CEN safe 4 Attachment point of tear-off se

    2 Attachment points of installation frame 5 Customer panel side3 Additional attachment points for 6 This side must always point

    CEN IV/V safe or alternative to the side with the safe door

    attachment points for CEN III

  • 7/24/2019 ProCash 2050xe ENG

    52/158

    Installation frame 222 mm (8.74") Planning the Installa

    44 ProCash 2050xe - Installation Guide 017500583

    CEN frame with cable lead-in dimensions

    159(6.2

    6")

    309

    (12.1

    7")

    599(23.5

    8")

    749(29.4

    9")

    787(30.9

    8")

    1

    1

    2

    3

    3

    3

    4

    2

    5

    6

    483.7(19.04")

    530.3(20.88")

    55(2.17")

    151(5.94")

    265(10.43")

    453(17.83")

    38.5

    (1.5

    2")

    55(2.1

    7")

    382(15.0

    3")

    462(18.1

    9")

    803(31.6

    1")

    1 Filling piece 4 Area for cables

    2 Cable feed opening 5 Customer panel side

    3 Cable exit opening underneath 6 This side must always point

    installation frame to the side with the safe door

  • 7/24/2019 ProCash 2050xe ENG

    53/158

    Planning the Installation Height-adjustable installation

    01750058390 B ProCash 2050xe - Installation Guide

    Height-adjustable installation rack

    General

    The installation rack has to be used if you want to install the ProCash 2050xe with 4-cassette dispenser in an existing wall opening and with different floor heights on the and outside. It consists of an upper and a lower part.

    The installation rack can be either a standard rack or a CEN rack (identified by the 'Csticker).

    The installation rack is secured to the floor at the attachment points (see section "Drdiagram for installation rack").Then the device is screwed to the installation rack.

    Openings which are not used have to be closed by putting in the filling pieces.

    For mounting material see section "Mounting sets" in the chapter "Installatio

    Securing the installation frames

    How the installation rack is secured depends on the resistance level (UL, CEN III or

    IV/V) of the safe. The label showing the resistance level is located on the inside of thsafe door.

    For a safe with resistance level III (CEN III) and UL, it is mandatory to secure theinstallation rack at the positions marked 1 with fourscrews.Positions 2 serve as alternative attachment points (see next illustrations).

    For a safe with resistance level IV/V (CEN IV/V), it is mandatory to secure the CEN rto the positions marked 1 and 2 with eightscrews (see next illustrations).

  • 7/24/2019 ProCash 2050xe ENG

    54/158

    Height-adjustable installation rack Planning the Installa

    46 ProCash 2050xe - Installation Guide 017500583

    Standard rack

    Lower part

    138(5.43")

    1

    1

    2

    2

    3

    4

    188(7.40")

    144

    (5.6

    7")

    1

    78(7.0

    1")

    288

    (11.3

    4")

    588(23.1

    5")

    638(25.1

    2")

    836(32.9

    1")

    400(15.75")

    450(17.72")

    466(18.35")588(23.15")

    5

    6

    1 Attachment points of installation rack 4 Area for cables

    2 Alternative attachment points 5 Customer panel side

    of installation rack with CEN / UL safe 6 This side must always point

    on the standard rack to the side with the safe door

    3 Attachment point of tear-off sensor

  • 7/24/2019 ProCash 2050xe ENG

    55/158

    Planning the Installation Height-adjustable installation

    01750058390 B ProCash 2050xe - Installation Guide

    Upper part

    182(7.17")

    3

    3

    4

    5

    1

    1

    2

    2

    3

    150

    (5.9

    1")

    690(27.1

    7")

    8

    8(33.3

    9")

    472(18.58")

    542(21.34")

    600(23.62")

    6

    7

    1 Filling piece 5 Area for cables

    2 Cable feed opening 6 Customer panel side3 Attachment points of CEN / UL safe 7 This side must always point

    4 Hole for tear-off sensor to the side with the safe door

  • 7/24/2019 ProCash 2050xe ENG

    56/158

    Height-adjustable installation rack Planning the Installa

    48 ProCash 2050xe - Installation Guide 017500583

    CEN rack

    Lower part

    2

    1

    4

    3

    1

    2

    574(22.6

    0")

    133

    (5.2

    4")

    207.5

    (8.1

    7")

    257.5

    (10.1

    4")

    624(24.5

    7")

    814(32.0

    5")

    566(22.28")455(17.91")

    439(17.28")389(15.31")

    177(6.97")

    127(5.00")

    5

    6

    1 Attachment points of installation rack 4 Area for cables

    2 Additional attachment points for 5 Customer panel side

    CEN IV/V safe or alternative 6 This side must always point

    attachment points for CEN III to the side with the safe door

    3 Attachment point of tear-off sensor

  • 7/24/2019 ProCash 2050xe ENG

    57/158

    Planning the Installation Height-adjustable installation

    01750058390 B ProCash 2050xe - Installation Guide

    Upper part

    179(7.05")

    3

    3

    4

    5

    1

    1

    2

    2

    3

    147

    (5.7

    9")

    687(27.0

    5")

    842(33.1

    5")

    469(18.46")539(21.22")

    594(23.39")

    6

    7

    1 Filling piece 5 Area for cables

    2 Cable feed opening 6 Customer panel side

    3 Attachment points of CEN / UL safe 7 This side must always point

    4 Hole for tear-off sensor to the side with the safe door

  • 7/24/2019 ProCash 2050xe ENG

    58/158

    Height-adjustable installation rack Planning the Installa

    50 ProCash 2050xe - Installation Guide 017500583

    Finding the required installation rack

    Three different installation racks are available to compensate any existing heightdifference between the floor outside and inside.

    Use the following formula to determine the required rack height (see also illustrationthe section "Installation options 4-cassette dispenser"):

    Xheight= Xwall 648 mm (25.51")

    Compare the result with the values in the first column of the following table. Therequired rack height Xrackis listed in the right column.

    Adjustable height Xheight Required rack height Xrack

    from 130 mm (5.12") to 190 mm (7.48") 93 mm (3.66")from 190 mm (7.48") to 320 mm (12.6") 152 mm (5.98")

    from 310 mm (12.2") to 530 mm (20.87") 270 mm (10.63")

  • 7/24/2019 ProCash 2050xe ENG

    59/158

    Planning the Installation Tear-off s

    01750058390 B ProCash 2050xe - Installation Guide

    Tear-off sensor

    All safes, installation frames and installation racks have holes for mounting aoff sensor.

    To ensure that the tear-off sensor can be mounted after the device has been installehole for the tear-off sensor has to be drilled at the time the installation frame or theinstallation rack is mounted.

    To be able to mount the tear-off sensor, the hole has to be cleaned with a vacuum cland an anchor bolt (e.g. UPAT multicone, Fischer resin cartridge R M) has to be inse

    Thus the alarm technician will be able to mount the tear-off sensor in the safe easily the device is installed (see also illustration "Mounting structure with CEN III, CEN IV

    safe" or "Mounting structure with UL safe" in the corresponding sections of the chapt"Installation").

    Ask your alarm technician about the size of the hole and the cartridge. The mountingmaterial (threaded rod, cartridge) is to be provided by the alarm technician. The lengthe threaded rod depends on the installation frame or the installation rack you use (schapter "Installation").

    Drilling diagrams

    The following figures specify the distance from the edge of the device (safe) of the dholes that are used to secure ProCash 2050xe to the installation frame or installation

  • 7/24/2019 ProCash 2050xe ENG

    60/158

    Drilling diagrams Planning the Installa

    52 ProCash 2050xe - Installation Guide 017500583

    Drilling diagram for 25 mm (0.98") installation frame

    The illustration shows the standard installation frame.

    The hole sizes and/or the drilling diagram for the CEN frame are identical.

    The installation frame is 3 mm (0.12") smaller than the safe all around.

    107(4.21")

    471.5(18.56")

    150

    (5.9

    1")

    188

    (7.4

    0")

    278

    (10.9

    4")

    578(22.7

    6")

    668(26.3

    0")

    482(18.98")

    Drilling depth:

    Holes for installation frame: at least 180 mm (7.09"), at least 125 mm (4.92") of wh

    in the concrete, for diameter see the operating manuasupplied with the mounting set.

    Hole for tear-off sensor: at least 40 mm (1.57") in concrete.Ask your alarm technician about the hole diameter andthe cartridge to be used.

  • 7/24/2019 ProCash 2050xe ENG

    61/158

    Planning the Installation Drilling diag

    01750058390 B ProCash 2050xe - Installation Guide

    Drilling diagram for 222 mm (8.74") installation frame

    The illustration shows the standard installation frame.

    The hole sizes and/or the drilling diagram for the CEN frame are identical.

    The installation frame is 3 mm (0.12") smaller than the safe all around.

    240(9.45")

    472(18.58")

    150

    (5.9

    1")

    197

    (7.7

    6")

    277

    (10.9

    1")

    599(23.5

    8")

    682(26.8

    5")

    484 (19.06")

    Drilling depth:

    Holes for installation frame: at least 180 mm (7.09"), at least 125 mm (4.92") of wh

    the concrete, for diameter see the operating manualsupplied with the mounting set.

    Hole for tear-off sensor: at least 40 mm (1.57") in concrete.Ask your alarm technician about the hole diameter andcartridge to be used.

  • 7/24/2019 ProCash 2050xe ENG

    62/158

    Drilling diagrams Planning the Installa

    54 ProCash 2050xe - Installation Guide 017500583

    Drilling diagram for the installation rack

    Standard rack

    The lower part of the installation rack is 6 mm (0.12") smaller than the safe allaround.

    144(5.67")

    194(7.64")

    406(15.98")

    456(17.95")

    150(5.9

    1")

    184(7.2

    4")

    294(11.5

    7")

    594(23.3

    9")

    644(25.3

    5")

    472(18.58")

    Drilling depth:

    Holes for installation frame: at least 180 mm (7.09"), at least 125 mm (4.92") ofwhich in the concrete, for diameter see the operatinmanual supplied with the mounting set.

    Hole for tear-off sensor: at least 40 mm (1.57") in concrete.Ask your alarm technician about the hole diameter athe cartridge to be used.

  • 7/24/2019 ProCash 2050xe ENG

    63/158

    Planning the Installation Drilling diag

    01750058390 B ProCash 2050xe - Installation Guide

    CEN rack

    The lower part of the installation rack is 17 mm (0.67") smaller than the safearound.

    591(23.2

    7")

    641(25.2

    4")

    144(5.67")

    194(7.64")

    406(15.98")

    456(17.95")

    472(18.58")

    150(5.9

    1")

    224.5

    (8.8

    4")

    274.5

    (10.8

    1")

    Drilling depth:

    Holes for installation frame: at least 180 mm (7.09"), at least 125 mm (4.92") o

    which in the concrete, for diameter see the operatimanual supplied with the mounting set.

    Hole for tear-off sensor: at least 40 mm (1.57") in concrete.Ask your alarm technician about the hole diameterthe cartridge to be used.

  • 7/24/2019 ProCash 2050xe ENG

    64/158

    Power and data cables Planning the Installa

    56 ProCash 2050xe - Installation Guide 017500583

    Power and data cables

    General information

    When the cables enter the device from below, make sure that the cables cannobe sheared off when the system is moved.

    To connect the device, power and data cables are required. In standard deliveries, theconnections for all the device's power and data cables are situated near the cable feedopening of the safe. The additional power cable that is provided has a standard length o2.5 m (8.2 ft). Other ready-to-use lengths of power and data cables can be ordered ifneeded via the hardware configurator or must be provided by the customer. Please refeto the corresponding illustrations in this guide for the positioning of the cables.

    To lay the cables inside the installation frame or rack and in the safe, filling pieces mayremoved so that cable sets can be inserted in the cable feed openings (see drawing).These filling pieces must then be replaced after the cables have been installed. The caexit points in the floor must be kept clear to ensure that the cables are not bent ordamaged.

    Make sure that the cables provided on-site are long enough to be laid through tinstallation frame or through the installation rack into the safe.

    1

    1 Cable feed opening

    You will also find details of the position of cable routing for the device in thesections "Installation frame 25 mm (0.98")" or "Installation frame 222 mm (8.74or "Height-adjustable installation rack".

  • 7/24/2019 ProCash 2050xe ENG

    65/158

    Planning the Installation Power and data c

    01750058390 B ProCash 2050xe - Installation Guide

    Power supply

    The device must only be connected to a TN system. In addition to the power supply the device, grounding outlets must be provided by the customer for supplementary

    equipment such as a modem.

    L N P E

    2

    3

    4

    1

    1 Fuse or automatic circuit-breaker 3 Modem connection

    2 ProCash 2050xe connection 4 Connection of miscellaneous equip

    (incl. optional heating)

    Remote status indicator

    The optional remote status indicator comes with a 50 m (164.1 ft) connecting cable.During planning, the position for installation and cable routing must be defined (see achapter "Installing the remote status indicator").

  • 7/24/2019 ProCash 2050xe ENG

    66/158

    Logo Planning the Installa

    58 ProCash 2050xe - Installation Guide 017500583

    Logo

    If the ProCash 2050xe was ordered without a logo, the logo has to be providedthe customer. The illustration shows the visible surface. The actual dimensionsare 465 mm x 171 mm (18.31" x 6.73").

  • 7/24/2019 ProCash 2050xe ENG

    67/158

    Planning the Installation Transport path requirem

    01750058390 B ProCash 2050xe - Installation Guide

    Transport path requirements

    The device is equipped with a shipping crate and can be transported with a pallet lift The forks of the truck must be pushed as far as possible underneath the device from

    side of the safe door.

    The entire transportation route, like the installation site, must be checked for load caand, if necessary, strengthened as appropriate before the installation date. Observe ambient condition requirements in the chapter "Appendix", section "Technical data" ftransportation and storage.

    Due to the shipping crate some dimensions are different (see illustrations below).

  • 7/24/2019 ProCash 2050xe ENG

    68/158

    Transport path requirements Planning the Installa

    60 ProCash 2050xe - Installation Guide 017500583

    Transport measurements for ProCash 2050xe

    ProCash 2050xe with 4-cassette dispenser

    848 (33.39")72/43*

    1208 (47.56")

    796(31.3

    4")

    145(5.7

    1")

    1645(64.7

    6")

    580 (22.83")

    690 (27.17")

    145(5.7

    1")

    (1.69" / 2.83" *)

    1 Shipping crate

    * Standard lock: 43 mm (1.69")Customer-specific lock: 72 mm (2.83")

  • 7/24/2019 ProCash 2050xe ENG

    69/158

    Planning the Installation Transport path requirem

    01750058390 B ProCash 2050xe - Installation Guide

    ProCash 2050xe with 6-cassette dispenser

    1905(75")

    580 (22.83")

    690 (27.17")

    145(5.7

    1")

    848 (33.39")72/43*

    1208 (47.56")

    1 0 5 6 ( 4 1

    5 7 " )

    145(5.7

    1")

    (1.69"/2.83"*)

    1 Shipping crate

    * Standard lock: 43 mm (1.69")Customer-specific lock: 72 mm (2.83")

  • 7/24/2019 ProCash 2050xe ENG

    70/158

    Transport path requirements Planning the Installa

    62 ProCash 2050xe - Installation Guide 017500583

    Check beforehand if there is enough space to move the device through doors hallways.

    The following illustration (scale 1:20) should help you determine if the space issufficient. It shows the device on a standard lift truck.

    With the help of the grid (100 mm x 100 mm (3.94" x 3.94")) you can draw theactual dimensions of the door and the hallway to find out if there is enough spafor transportation. Refer to the next page for an example.

    In the appendix there is a drawing of the device with a lift truck on a scale of 1which may serve as a template.

    1580(62.20")

    1350(53.15")

    520(20.4

    7")

    690(27.1

    7")

  • 7/24/2019 ProCash 2050xe ENG

    71/158

    Planning the Installation Transport path requirem

    01750058390 B ProCash 2050xe - Installation Guide

    Example with minimum transport path measurements

    740(29.13")

    1900(74.8

    0")

    1580(62.20")

    1350(53.15")

    520(20.4

    7")

    690(27.1

    7")

  • 7/24/2019 ProCash 2050xe ENG

    72/158

    Transport path requirements Planning the Installa

    64 ProCash 2050xe - Installation Guide 017500583

  • 7/24/2019 ProCash 2050xe ENG

    73/158

    01750058390 B ProCash 2050xe - Installation Guide

    Installation

    This chapter describes the individual steps to be taken to install the device.

    All dimensions are specified in millimeters (inches). The diagrams are not drto scale.

    Contact the person in charge of planning the installation to verify that allpreparations have been performed completely and professionally and that n

    the required power and data cables are missing.

    Removing the packaging

    Remove the packing material of the ProCash 2050xe.

    Dispose of the packaging which is no longer needed according to the regulationsyour country.

  • 7/24/2019 ProCash 2050xe ENG

    74/158

    Removing the shipping crate Installa

    66 ProCash 2050xe - Installation Guide 017500583

    Removing the shipping crate

    General information

    For transportation the device is equipped with a shipping crate which must be removedprior to the installation.

    To move the device only push against the sides of the safe as shown in theillustration below.

    Removing the shipping crate

    Proceed as follows to remove the shipping crate:

    Lift the device.

    Remove the screws of the shipping crate fromunderneath.

    Remove the shipping crate from theProCash 2050xe (1).

    Please return the shipping crate which is no longer needed to Wincor NixdorfInternational GmbH. Please contact your vendor, if necessary.

  • 7/24/2019 ProCash 2050xe ENG

    75/158

    Installation Mountin

    01750058390 B ProCash 2050xe - Installation Guide

    Mounting sets

    The mounting sets are supplied with the installation frame or the installation of the ProCash 2050.

    The mounting set for the tear-off sensor is not supplied with the device.

    Mounting set 01750051579 for installation frame or installation r

    For a CEN IV/V safe two mounting sets 01750051579 are supplied.

    Item Quantity requiredCEN III/UL safe

    Quantity requCEN IV/V safe

    Caulking cartridgeA caulking gun for the cartridge isnotincluded in the shipment.

    1 2

    Threaded rod M16 x 200(DIN 976, property class 10.9)

    4 8

    Hexagon nut M16 (DIN 971-1) 4 8

    Washer A 17 DIN 125-St 4 8

    Mounting set for safe on 25 mm (0.98") installation frame

    Item Quantity requ

    Pan head screw M16 x 40(DIN 912, property class 10.9)

    4

    Washer A 17 DIN 125-St 4

    Mounting set for safe on 222 mm (8.74") installation frame orinstallation rack

    Item Quantity requ

    Pan head screw M16 x 60(DIN 912, property class 10.9)

    4

    Washer A 17 DIN 125-St 4

  • 7/24/2019 ProCash 2050xe ENG

    76/158

    Overview of installation options Installa

    68 ProCash 2050xe - Installation Guide 017500583

    Overview of installation options

    Installation options Same floorheight

    Different flooheight

    Installation with 25 mm (0.98") installation frame(Pro Cash 2050xe with 6cassette dispenser)

    (see p.69) yes no

    Installation with 25 mm (0.98") installation frame on

    a concrete base (see p.69) yes yes

    Installation with 222 (8.74") installation frame(see p.77)

    yes no

    Installation with height-adjustable installation

    rack (see p.86) no yes

  • 7/24/2019 ProCash 2050xe ENG

    77/158

    Installation Installation with 25 mm (0.98") installation

    01750058390 B ProCash 2050xe - Installation Guide

    Installation with 25 mm (0.98") installation frame

    Installing the installation frame

    Observe the required maintenance space when positioning the device and thinstallation frame (see chapter "Planning the Installation", section "Requiredoperation and maintenance space").

    Make sure that the clearance between the vents and the wall is at least50 m(1.97") (53 mm(2.09") in relation to the installation frame).

    Align the installation frame and mark the holes for mounting the installation frame

    illustrations below).

    When using the CEN frame for CEN safes:

    How the CEN frame is secured depends on the resistance level (III or IV/the safe (see also the note accompanying the illustration "Position of themm (0.98") CEN frame").

    The security level is noted on the inside of the safe door.

    If a tear-off sensor is to be installed as agreed with the financial institutio

    the alarm technician, also mark the holes for the tear-off sensor (seeillustration below).

  • 7/24/2019 ProCash 2050xe ENG

    78/158

    Installation with 25 mm (0.98") installation frame Installa

    70 ProCash 2050xe - Installation Guide 017500583

    Position of the 25 mm (0.98") standard frame

    The standard frame is secured withfourscrews in the places marked 2.

    13.5 (0.53")9

    8

    10

    12 12

    2

    3

    21

    283.5(11.16")

    310.5(12.22")

    550 (21.65")

    4

    56

    6

    7

    7

    1

    3

    11

    1 Attachment points of CEN/UL safe 6 Area for cables

    2 Attachment points of installation 7 Cable feed opening underneath

    frame Installation frame

    3 Alternative attachment points of 8 Center of standard frame

    installation frame for CEN/UL 9 Center of wall opening

    safe on standard frame 10 Side with customer panel

    4 Attachment point of tear-off sensor 11 This side must always point

    5 Opening to feed cables into the

    installation

    towards the safe door

    frame 12 Wall

    W * Wall thickness for 35 mm (1.38") tunnel width: max. 360 mm (14.17")

    Wall thickness for 60 mm (2.36") tunnel width: max. 335 mm (13.19")

    P * Position of the installation frame for 35 mm (1.38") tunnel width: 368 5 mm(14.49" 0.2")

  • 7/24/2019 ProCash 2050xe ENG

    79/158

    Installation Installation with 25 mm (0.98") installation

    01750058390 B ProCash 2050xe - Installation Guide

    Position of the installation frame for 60 mm (2.36") tunnel width: 343 5 mm(13.5" 0.2")

    Position of the 25 mm (0.98") CEN frame

    For a CEN III safe it is mandatory to secure it in the places marked 2 with foscrews. For a CEN IV/V safe it is mandatory to secure it in the places markeand 3 witheightscrews (see following illustration).

    9

    8

    10

    11

    12 12

    2

    3

    2

    1

    283.5(11.16")

    310.5(12.22")

    550 (21.65")

    4

    56

    7

    6

    1

    3

    1 Attachment points of CEN safe 6 Cable feed opening undernea

    2 Attachment points of installation Installation frame

    frame 7 Area for cables

    3 Additional attachment points of 8 Center of standard frame

    CEN IV/V safe or alternative 9 Center of wall opening

    attachment points of CEN III safe 10 Side with customer panel

    4 Attachment point of tear-off sensor 11 This side must always point

    5 Opening to feed cables into theinstallation

    towards the safe door

    frame 12 Wall

    W * Wall thickness for 35 mm (1.38") tunnel width: max. 360 mm (14.17")

    Wall thickness for 60 mm (2.36") tunnel width: max. 335 mm (13.19")

  • 7/24/2019 ProCash 2050xe ENG

    80/158

    Installation with 25 mm (0.98") installation frame Installa

    72 ProCash 2050xe - Installation Guide 017500583

    P * Position of the installation frame for 35 mm (1.38") tunnel width: 368 5 mm(14.49" 0.2")

    Position of the installation frame for 60 mm (2.36") tunnel width: 343 5 mm(13.5" 0.2")

    Drill the four and/or eight required holes and the hole for the tear-off sensor (see thefollowing illustrations).

    To ensure that the safe does not become detached, the threaded rods of thinstallation frame must be fastened in the concrete foundation.

    The drilled holes in the concrete foundation must have a depth of at least 1mm (4.92") for the installation frame (see illustrations below).For the hole diameter please refer to the instructions shipped with themounting set.

    The drilled hole in the concrete foundation must have a depth of at least 40mm (1.57") for the tear-off sensor (see illustrations below). Consult your alatechnician about the size of the hole and the cartridge.

  • 7/24/2019 ProCash 2050xe ENG

    81/158

    Installation Installation with 25 mm (0.98") installation

    01750058390 B ProCash 2050xe - Installation Guide

    Mounting structure with CEN III, CEN IV/V safe

    1

    2 3 54

    8

    7 6

    25

    (0.9

    8")

    180*(7.0

    9")

    min.

    125

    min.

    40

    (min.

    1.5

    7")

    (min.

    4.9

    2")

    Mounting structure with UL safe

    7 6

    1

    2 3 4 5

    25(0.9

    8")

    180*(7.0

    9")

    min.

    125

    min.

    40

    (min.

    157")

    (min.

    4.9

    2")

    1 Safe 5 Mounting set for installation frame

    2 Mounting set for safe 6 Concrete

    3 Tear-off sensor 7 Screed

    4 Installation frame 8 Top surface of finished floor

    * This distance depends on the screed height. The threaded rod included in themounting set must either be adapted or replaced.

  • 7/24/2019 ProCash 2050xe ENG

    82/158

    Installation with 25 mm (0.98") installation frame Installa

    74 ProCash 2050xe - Installation Guide 017500583

    Clean the drill holes as specified in the instructions delivered with the mounting set.

    Secure the threaded rods in the concrete foundation as specified in the instructionsdelivered with the mounting set.

    Insert the cartridge for the tear-off sensor if required.

    Screw the installation frame to the pedestal (for material see section "Mounting setsIf applicable, note the hardening times of the mounting material.

    Mounting the device on the installation frame

    Remove the appropriate filling pieces from the cable lead-in (position 5 in theillustrations "Position of the 25 mm (0.98") standard frame" (see p. 70)or "Position othe 25 mm (0.98") CEN frame" (see p. 71)).

    If the connecting cables on the site are nolocated on the safe door side:

    Insert the data cables and the power cablethrough the cable lead-ins and if necessarythrough the cable openings behind the safedoor side (11) of the installation frame, as in example shown here.

  • 7/24/2019 ProCash 2050xe ENG

    83/158

    Installation Installation with 25 mm (0.98") installation

    01750058390 B ProCash 2050xe - Installation Guide

    Push the device onto the installation frame. Ensure that no cables are damaged iprocess.

    Open the safe door (see chapter "Basic Operation", section "Opening / closing th

    door (with factory setting)" or "Opening / closing the safe door (with customized loin the operating manual).

    If it is necessary for the installation remove those parts inside the unit which secucomponents during transportation (see enclosed information sheet).

    Pull out the CMD-V4 (see chapter "Basic Operation" in the operating manual).

    2

    Put the two track stops (1) (to be found in tsafe) in place as shown in the illustration.

    Remove the securing screw (2) at the endthe pull-out track, one each on the right anthe left side.

    Remove the uppermost cash-out cassette(see chapter "Cash Media Dispenser (CMDV4)" in the operating manual).

    Swing the CMD-V4 (1) up until the hole (2)above the pull-out tracks is visible. Push thlocking axle (3) (to be found in the safe) in the grooves are in line with the side panelsthe CMD-V4 rack.

    Check the firm fit of the CMD-V4 by movingslightly back and forth.

    When mounting the locking axle enthat no cables are damaged in theprocess.

    2

    Check the CMD-V4 for a secure fit.locking axle must be firmly in place

  • 7/24/2019 ProCash 2050xe ENG

    84/158

    Installation with 25 mm (0.98") installation frame Installa

    76 ProCash 2050xe - Installation Guide 017500583

    Place the device on the installation frame andalign it (for attachment points (1) and (2) plearefer to the illustration) and fasten the safe tothe installation frame using screws (for matersee section "Mounting sets"). First tighten the

    rear screws (2) and then the front screws (1) the safe.

    Lift the CMD-V4 slightly and pull out the locking axle. Carefully lower the CMD-V4.

    When lifting or lowering the CMD-V4 make sure that the connecting cablesthe rear side of the CMD-V4 controller are not damaged and that they are nmoved around!

    Mount both securing screws.

    Remove the two track locks and push the CMD-V4 back in.

    Re-insert the uppermost cash-out cassette.

    Remove the filling piece of the safe.

    Feed the data cables and the power cable into the safe.

    Replace the filling piece of the installation frame (position 5) and the filling piece of tsafe.

    Close the device.

    If the tunnel frame is to be installed immediately afterwards release the custompanel (see chapter "Basic Operation", section "Pulling out / pushing in thecustomer panel" in the operating manual).

  • 7/24/2019 ProCash 2050xe ENG

    85/158

    Installation Installation with 222 mm (8.74") installation

    01750058390 B ProCash 2050xe - Installation Guide

    Installation with 222 mm (8.74") installation frame

    Installing the installation frame

    Observe the required maintenance space when positioning the device and thinstallation frame (see chapter "Planning the Installation", section "Requiredoperation and maintenance space").

    Make sure that the clearance between the vents and the wall is at least50 m(1.97") (53 mm(2.09") in relation to the installation frame).

    Align the installation frame and mark the holes for mounting the installation frame

    illustrations below).

    When using the CEN frame for CEN safes:

    How the CEN frame is secured depends on the resistance level (III or IV/the safe (see also the note accompanying the illustration "Position of the222 mm (8.74") CEN frame").

    The security level is noted on the inside of the safe door.

    If a tear-off sensor is to be installed as agreed with the financial institutio

    the alarm technician, also mark the holes for the tear-off sensor (seeillustration below).

  • 7/24/2019 ProCash 2050xe ENG

    86/158

    Installation with 222 mm (8.74") installation frame Installa

    78 ProCash 2050xe - Installation Guide 017500583

    Position of the 222 mm (8.74") standard frame

    The standard frame is secured withfourscrews in the places marked 2.

    13.5 (0.53")9

    810

    11

    12 12

    2

    2

    3

    3

    1

    283.5

    (11.16")

    310.5

    (12.22")

    550 (21.65")

    4

    5

    5

    6

    6

    6

    7

    7

    7

    1

    1 Attachment points of CEN/UL safe 7 Cable feed opening underneath

    2 Attachment points of installation frame installation frame

    3 Alternative attachment points of 8 Center of standard frame

    installation frame for CEN/UL 9 Center of wall opening

    safe on standard frame 10 Side with customer panel

    4 Attachment point of tear-off sensor 11 This side must always point

    5 Opening to feed cables into the towards the safe door

    installation frame 12 Wall

    6 Area for cablesW * Wall thickness for 35 mm (1.38") tunnel width: max. 360 mm (14.17")

    Wall thickness for 60 mm (2.36") tunnel width: max. 335 mm (13.19")

    P * Position of the installation frame for 35 mm (1.38") tunnel width: 368 5 mm(14.49" 0.2")

    Position of the installation frame for 60 mm (2.36") tunnel width: 343 5 mm(13.5" 0.2")

  • 7/24/2019 ProCash 2050xe ENG

    87/158

    Installation Installation with 222 mm (8.74") installation

    01750058390 B ProCash 2050xe - Installation Guide

    Position of the 222 mm (8.74") CEN frame

    For a CEN III safe it is mandatory to secure it in the places marked 2 with fos