PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf ·...

108
Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual Edition December 2012

Transcript of PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf ·...

Page 1: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

Operating Manual - English

PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

Edition December 2012

Page 2: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

Copyright and Trademarks

Comments… Suggestions… Corrections…The User Documentation Department would like toknow your opinion of this manual. Your feedback helpsus optimize our documentation to suit your individual needs.

Feel free to send us your comments by e-mail to [email protected].

Certified documentation according to DIN EN ISO 9001:2008To ensure a consistently high quality standard anduser-friendliness, this documentation was created tomeet the regulations of a quality management system which complies with the requirements of the standardDIN EN ISO 9001:2008.

cognitas. Gesellschaft für Technik-Dokumentation mbHwww.cognitas.de

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

63-0

01.fm

Copyright 2012 FUJITSU LIMITED

All rights reserved.Delivery subject to availability; right of technical modifications reserved.

All hardware and software names used are trademarks of their respective manufacturers.

– The contents of this manual may be revised without prior notice.

– Fujitsu assumes no liability for damages to third party copyrights or other rights arising fromthe use of any information in this manual.

– No part of this manual may be reproduced in any without the prior written permission ofFujitsu.

Microsoft, Windows, Windows Server, and Hyper V are trademarks or registered trademarks of Microsoft Corporation in the USA and other countries.

Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the USA and other countries.

Page 3: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual

Before reading this manual

For your safety

This manual contains important information for safely and correctly using this product.

Carefully read the manual before using this product. Pay particular attention to the accompanying manual "Safety Notes and Regulations" and ensure these safety notes are understood before using the product. Keep this manual and the manual "Safety Notes and Regulations" in a safe place for easy reference while using this product.

Radio interference

This product is a "Class A" ITE (Information Technology Equipment). In a domestic environment this product may cause radio interference, in which case the user may be required to take appropriate measures. VCCI-A

Aluminum electrolytic capacitors

The aluminum electrolytic capacitors used in the product's printed circuit board assemblies and in the mouse and keyboard are limited-life components. Use of these components beyond their operating life may result in electrolyte leakage or depletion, potentially causing emission of foul odor or smoke.

As a guideline, in a normal office environment (25°C) operating life is not expected to be reached within the maintenance support period (5 years). However, operating life may be reached more quickly if, for example, the product is used in a hot environment. The customer shall bear the cost of replacing replaceable components which have exceeded their operating life. Note that these are only guidelines, and do not constitute a guarantee of trouble-free operation during the maintenance support period.

High safety use

This product has been designed and manufactured to be used in commercial and/or industrial areas as a server.

When used as visual display workplace, it must not be placed in the direct field of view to avoid incommoding reflections (applies only to TX server systems).

The device has not been designed or manufactured for uses which demand an extremely high level of safety and carry a direct and serious risk of life or body if such safety cannot be assured.

Page 4: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

Operating Manual BX900S2

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

63-0

01.fm

These uses include control of nuclear reactions in nuclear power plants, automatic airplane flight control, air traffic control, traffic control in mass transport systems, medical devices for life support, and missile guidance control in weapons systems (hereafter, "high safety use"). Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use. Please consult the sales staff of Fujitsu if intending to use this product for high safety use.

Measures against momentary voltage drop

This product may be affected by a momentary voltage drop in the power supply caused by lightning. To prevent a momentary voltage drop, use of an AC uninterruptible power supply is recommended.

(This notice follows the guidelines of Voltage Dip Immunity of Personal Computer issued by JEITA, the Japan Electronics and Information Technology Industries Association.)

Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan

Documents produced by Fujitsu may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan. Documents which contain such technology should not be exported from Japan or transferred to non-residents of Japan without first obtaining authorization in accordance with the above law.

Harmonic Current Standards

This product conforms to harmonic current standard JIS C 61000-3-2.

Only for the Japanese market:

I Although described in this manual, some sections do not apply to the Japanese market. These options and routines include:

– CSS (Customer Self Service)

Page 5: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual

Contents

1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

1.1 Concept and target groups for this manual . . . . . . . . . . 7

1.2 Documentation overview . . . . . . . . . . . . . . . . . . . . 8

1.3 Notational conventions . . . . . . . . . . . . . . . . . . . . 10

2 Functional overview . . . . . . . . . . . . . . . . . . . . . . 11

2.1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

2.2 System unit specification . . . . . . . . . . . . . . . . . . . 29

3 Installation steps, overview . . . . . . . . . . . . . . . . . . 33

4 Important information . . . . . . . . . . . . . . . . . . . . . 35

4.1 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . 35

4.2 CE conformity . . . . . . . . . . . . . . . . . . . . . . . . . 43

4.3 FCC Class A Compliance Statement . . . . . . . . . . . . . 43

4.4 Environmental protection . . . . . . . . . . . . . . . . . . . 45

5 Hardware installation . . . . . . . . . . . . . . . . . . . . . . 47

5.1 Unpacking the system unit . . . . . . . . . . . . . . . . . . 48

5.2 Installing/removing the system unit . . . . . . . . . . . . . . 495.2.1 Installation in PRIMECENTER/DataCenter rack . . . . . . . . . 515.2.2 Installing/removing the system unit . . . . . . . . . . . . . . . 57

5.3 Connecting devices to the system unit . . . . . . . . . . . . 605.3.1 Cable routing . . . . . . . . . . . . . . . . . . . . . . . . . . 61

5.4 Connecting the system unit to the mains . . . . . . . . . . 615.4.1 Using cable ties . . . . . . . . . . . . . . . . . . . . . . . . . 64

5.5 Notes on connecting/disconnecting cables . . . . . . . . . 65

Page 6: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

Operating Manual BX900S2

Contents

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

64-0

01.fm

6 Starting up and operation . . . . . . . . . . . . . . . . . . . . 67

6.1 Control and display elements . . . . . . . . . . . . . . . . . 676.1.1 Front of system . . . . . . . . . . . . . . . . . . . . . . . . . . 676.1.1.1 Control elements . . . . . . . . . . . . . . . . . . . . . . . 706.1.1.2 LEDs on the control panel . . . . . . . . . . . . . . . . . . . 706.1.1.3 ID card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 726.1.2 Back of system . . . . . . . . . . . . . . . . . . . . . . . . . . 736.1.2.1 Control and display elements on the management blade . . . 736.1.2.2 Indicators on the hot-plug power supply units . . . . . . . . . 766.1.2.3 Indicators on the hot-plug fans . . . . . . . . . . . . . . . . 776.1.3 Indicators and connectors of the connection blades . . . . . . . 786.1.3.1 Connection Blade GbE Switch/IBP 18/6 (SB6) . . . . . . . . 786.1.3.2 Connection Blade GbE Switch/IBP 36/12 (SB11A) . . . . . . 796.1.3.3 Connection Blade GbE Switch/IBP 36/8+2 (SB11) . . . . . . 816.1.3.4 Connection Blade 10 GbE Switch/IBP 18/8 . . . . . . . . . . 836.1.3.5 Connection Blade Ethernet Pass Thru 10Gb 18/18 . . . . . . 856.1.3.6 Connection Blade 8Gb FC Switch 18/8 . . . . . . . . . . . . 866.1.3.7 Connection Blade 8Gb FC Pass Thru 18/18 . . . . . . . . . 876.1.3.8 Connection Blade DCB SW 10Gb 18/6+6 . . . . . . . . . . . 886.1.3.9 Connection Blade FEX B22F 10Gb (Cisco) . . . . . . . . . . 906.1.3.10 Connection Blade Infiniband Switch 40 Gb 18/18 . . . . . . 916.1.3.11 Connection Blade Infiniband Switch 56 Gb 18/18 FDR . . . . 926.1.3.12 Connection Blade SAS Switch 6 Gb 18/6 . . . . . . . . . . . 93

6.2 Switching the system unit on/off . . . . . . . . . . . . . . . . 94

6.3 Configuring management blades . . . . . . . . . . . . . . . . 96

6.4 Cleaning the system unit . . . . . . . . . . . . . . . . . . . 102

7 Property and data protection . . . . . . . . . . . . . . . . . 103

8 Troubleshooting and tips . . . . . . . . . . . . . . . . . . . 105

8.1 System power indicator does not light up . . . . . . . . . . 105

8.2 Front or back error LED flashes orange . . . . . . . . . . . 106

8.3 System switches itself off . . . . . . . . . . . . . . . . . . . 107

Page 7: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 7

1 IntroductionThe PRIMERGY BX900 S2 system unit is a highly compact, energy-saving and scalable server system for installation in a 19-inch rack. The BX900 S2 system unit has space for up to 18 server and storage blades.

With its advanced infrastructure modules, the BX900 S2 system unit offers the server blades a high level of connectivity and availability. These include hot-plug connection blades, redundant management blades and power supply units, the server management of the ServerView suite, Prefailure Detection and Analyzing (PDA), and Automatic Server Reconfiguration and Restart (ASR&R).

Security functions in the BIOS-Setup of the server blades and on the system boards protect the data on the blade server from manipulation. Additional security is provided by the lockable rack door.

The BX900 S2 system unit takes up 10 height units (U) in the rack.

1.1 Concept and target groups for this manual

This operating manual describes how to install, set up and operate your system unit.

This operating manual is intended for those responsible for installing the hardware and ensuring that the system runs smoothly. It contains all the information you need to put your PRIMERGY BX900 S2 system unit into operation.

To understand the various expansion options, you will need to be familiar with the fields of hardware and data transmission and you will require a basic knowledge of the underlying operating system.

Page 8: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

8 Operating Manual BX900S2

Introduction

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

65-0

01.fm

1.2 Documentation overview

More information on your PRIMERGY BX900 S2 system unit can be found in the following documents:

– "Quick Start Hardware - PRIMERGY BX900 S2 Blade Server" leaflet " はじめにお読みください -PRIMERGY BX900 S2 Blade Server" for the Japanese market(only included as a printed copy)

– "Quick Start Software - Quick Installation Guide" DVD booklet (only included with the ServerView Suite as a printed copy)

– "Safety Notes and Regulations" manual" 安全上のご注意 " for the Japanese market

– "Warranty" manual" 保証書 " for the Japanese market

– "Returning used devices" manual and "Service Desk" leaflet" サポート&サービス " for the Japanese market

– "PRIMERGY BX900 S2 System Unit Operating Manual"

– "PRIMERGY BX900 S2 System Unit Upgrade and Maintenance Manual"

– “PRIMERGY BX900 Blade Server Systems ServerView Management Blade S1" User Interface Description

Page 9: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 9

Introduction

I PRIMERGY manuals are available in PDF format on the ServerView Suite DVD 2. The ServerView Suite DVD 2 is part of the ServerView Suite supplied with every server.

If you no longer have the ServerView Suite DVDs, you can obtain the relevant current versions using the order number U15000-C289 (the order number for the Japanese market: please refer to the configurator of the server http://jp.fujitsu.com/platform/server/primergy/system/).

The PDF files of the manuals can also be downloaded free of charge from the Internet. The overview page showing the online documentation available on the Internet can be found using the URL (for EMEA market): http://manuals.ts.fujitsu.com. The PRIMERGY server documentation can be accessed using the Industry standard servers navigation option.

For the Japanese market:

Please refer to the following URL for the latest product manuals:http://jp.fujitsu.com/platform/server/primergy/manual/

Before using the product, please check for additional information that may be available under the following URL:http://jp.fujitsu.com/platform/server/primergy/products/note/

Further sources of information:

– ServerView Suite Glossary on the ServerView Suite DVD 2– Manual for the monitor– Documentation for the boards and drives– Operating system documentation– Information files in your operating system

Page 10: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

10 Operating Manual BX900S2

Introduction

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

65-0

01.fm

1.3 Notational conventions

The following notational conventions are used in this manual:

Text in italics indicates commands or menu items."Quotation marks" indicate names of chapters and terms that are being

emphasized.Ê describes activities that must be performed in the order

shown.V CAUTION! pay particular attention to texts marked with this symbol.

Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data.

I indicates additional information, notes and tips.

Page 11: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 11

2 Functional overviewThis section provides information on the features and technical data of the PRIMERGY BX900 S2 system unit.

2.1 Features

Customer Self Service (CSS)

The PRIMERGY Customer Self Service (CSS) concept enables you to identify and replace the affected component yourself in the case of certain error scenarios.

In the CSS concept, you can replace the following components yourself in the event of an error:

– Hot-plug power supply units

– System fans

For information on replacing these components, see the "PRIMERGY BX900 S2 Upgrade and Maintenance Manual".

CSS indicators on the control panel and on the back of the PRIMERGY server provide you with information if a CSS event arises.

The ServerView Local Service Display for Blade enables you to identify the type of component affected by the error directly on the server.

In addition, CSS errors are displayed in the management blade web interface and in the ServerView Operations Manager, the server management software from Fujitsu.

In the event of errors, the ServerView Operations Manager refers you directly to the affected component and its order information in the Illustrated Spares catalog of the server in question. (This feature is not available for the Japanese market.)

I For the latest information on optional products provided for the BX900 S2 system unit see the configurator of the system unit:

http://ts.fujitsu.com/products/standard_servers/index.html (for the EMEA market)

Page 12: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

12 Operating Manual BX900S2

Functional overview

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

66-0

01.fm

http://jp.fujitsu.com/platform/server/primergy/system/ (for the Japanese market)

Server blades

The PRIMERGY BX900 S2 system unit has 18 half height or 9 full height bays on the front for server or storage blades.

Figure 1: Numbering of the server blade slots

1 2 3 4 17 5 6 7 8

9 10 11 12 18 13 14 15 16

Page 13: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 13

Functional overview

The following server blades are available for the BX900 S2 system unit.

PRIMERGY BX920 S2 server bladeProcessor type Intel® Xeon® 5500 or 5600 seriesProcessor quantity 1 - 2Max. per system unit 18Memory slots 9Maximum memory capacity 144 GB

PRIMERGY BX920 S3 server bladeProcessor type Intel® Xeon® processor E5-2400

familyProcessor quantity 1 - 2Max. per system unit 18Memory slots 12Maximum memory capacity 384 GB

PRIMERGY BX922 S2 server bladeProcessor type Intel® Xeon® 5500 or 5600 seriesProcessor quantity 1 - 2Max. per system unit 18Memory slots 12Maximum memory capacity 192 GB

PRIMERGY BX924 S2 server bladeProcessor type Intel® Xeon® 5500 or 5600 seriesProcessor quantity 1 - 2Max. per system unit 18Memory slots 18Maximum memory capacity 288 GB

Page 14: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

14 Operating Manual BX900S2

Functional overview

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

66-0

01.fm

I The maximum number of installable server blades depends on the number of power supply units and fan modules fitted in the system unit, the available mains voltage and the redundant power supply requirements, see the "PRIMERGY BX900 S2 System Unit Upgrade and Maintenance Manual".

For further information on the server blades, see the relevant operating manuals.

PRIMERGY BX924 S3 server bladeProcessor type Intel® Xeon® processor E5-2600

familyProcessor quantity 1 - 2Max. per system unit 18Memory slots 24Maximum memory capacity 768 GB

PRIMERGY BX960 S1 server bladeProcessor type Intel® Xeon® 7500 seriesProcessor quantity 2 - 4Max. per system unit 9Memory slots 32Maximum memory capacity 512 GB

Page 15: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 15

Functional overview

Storage blades

Storage blades can be used to extend the internal storage capacity of the server blades.

PRIMERGY SX910 S1 storage bladeStorage media LTO tape driveTape slots quantity 1Max. per system unit 6Installable in slots 2 - 17 - 7 - 10 - 18 - 15Connected to server blade in the adjacent slot to

the left or to the right

PRIMERGY SX940 S1 storage bladeStorage media 2.5 inch HDD or SSD modulesDisk slots quantity 4Max. per system unit 6Installable in slots 2 - 17 - 7 - 10 - 18 - 15Connected to server blade in the adjacent slot to

the left or to the right

PRIMERGY SX960 S1 storage bladeStorage media 2.5 inch HDD or SSD modulesDisk slots quantity 10Max. per system unit 2Installable in slots 7/8 - 15/16Connected to server blade in the adjacent slot to

the left

Page 16: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

16 Operating Manual BX900S2

Functional overview

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

66-0

01.fm

PRIMERGY SX980 S1 storage bladeStorage media 2.5 inch HDD or SSD modulesDisk slots quantity 10Max. per system unit 3Installable in slots 1/2 - 3/4 - 5/6 - 7/8 - 9/10 - 11/12 -

13/14 - 15/16Connected to server blades with SAS

mezzanine card via SAS connection blade

PRIMERGY SX980 S2 storage bladeStorage media 2.5 inch HDD or SSD modulesDisk slots quantity 10Max. per system unit 3Installable in slots 1/2 - 3/4 - 5/6 - 7/8 - 9/10 - 11/12 -

13/14 - 15/16Connected to server blades with SAS

mezzanine card via SAS connection blade

I This storage blade provides dual port / redundant SAS connections to the SAS drives.

Page 17: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 17

Functional overview

Connection blades

The PRIMERGY BX900 S2 system unit has eight slots for connection blades on the back. Connection blades provide the installed server blades with connections to the Ethernet LAN as well as to SAN environments and SAS storage environments.

The connection blade slots of the BX900 S2 system unit are numbered as follows.

Figure 2: Connection blade slots

CB1

CB3

CB5

CB7

CB2

CB4

CB6

CB8

Fabric 1

Fabric 2

Fabric 3

Fabric 4

Page 18: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

18 Operating Manual BX900S2

Functional overview

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

66-0

01.fm

Each pair of adjacent connection blade slots forms a so-called fabric. The following table shows how you can fill the fabrics and which network components of the server blades they are connected to:

V CAUTION!

● The downlink ports of connection blades DCB SW 10Gb and FEX B22F 10Gb (Cisco) operate only at 10 Gb link speed.

● The two connection blades within a fabric must have the same technology, i.e. either Ethernet, Fibre Channel, SAS or Infiniband.

System unit Server blade

Connection blade slots

Fabric 1

CB1: 1Gb Ethernet or CB2: 1Gb Ethernet or

10 Gb Ethernet or 10 Gb Ethernet or Onboard LAN controller /

DCB SW 10Gb or DCB SW 10Gb or Onboard CNA controller

FEX B22F 10Gb (Cisco)

FEX B22F 10Gb (Cisco)

Fabric 2

CB3: 1Gb Ethernet or CB4: 1Gb Ethernet or

Mezzanine card 1

10 Gb Ethernet or 10 Gb Ethernet or

DCB SW 10Gb or DCB SW 10Gb or

FEX B22F 10Gb (Cisco) or

FEX B22F 10Gb (Cisco) or

Fibre Channel or Fibre Channel or

Infiniband (CB3/4)

Fabric 3

CB5: 1Gb Ethernet or CB6: 1Gb Ethernet or

Mezzanine card 2

10 Gb Ethernet or 10 Gb Ethernet or

DCB SW 10Gb or DCB SW 10Gb or

FEX B22F 10Gb (Cisco) or

FEX B22F 10Gb (Cisco) or

Fibre Channel or Fibre Channel or

SAS or SAS or

Infiniband (CB5/6)

Fabric 4CB7: 1Gb Ethernet or CB8: 1Gb Ethernet or

Infiniband (CB7/8)

Table 1: Fitting rules for connection blade slots

Page 19: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 19

Functional overview

When filling the slots in fabrics 2, 3 and 4, also make sure the server blades are fitted with the appropriate mezzanine cards.

I For information about port assignment of connection blades and corresponding mezzanine cards, please refer to the "PRIMERGY BX900 S2 System Unit Upgrade and Maintenance Manual".

The following connection blades are available for the BX900 S2 system unit:

Ethernet connection blades

Connection Blade GbE Switch/IBP 18/6 (SB6)18 internal 1-Gbit/s ports to the server blades6 external 1-Gbit/s ports through RJ45 connectionsInstallable in all connection blade slotsI This connection blade can be used as a layer-2 switch or an

Intelligent Blade Panel (IBP).

1Gb Ethernet connection blades in slots CB3/4 (fabric 2), CB5/6 (fabric 3) and CB7/8 (fabric 4) only support server blades that are fitted with an 1 Gb Ethernet mezzanine card.

Connection Blade GbE Switch/IBP 36/12 (SB11A)36 internal 1-Gbit/s ports to the server blades8 external 1-Gbit/s ports through RJ45 connections4 external 1-Gbit/s ports through SFP modulesInstallable in all connection blade slotsI This connection can be used as a layer-2 switch or an Intelligent

Blade Panel (IBP).

1 Gb Ethernet connection blades in slots CB3/4 (fabric 2), CB5/6 (fabric 3) and CB7/8 (fabric 4) only support server blades that are fitted with an 1 Gb Ethernet mezzanine card.

Page 20: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

20 Operating Manual BX900S2

Functional overview

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

66-0

01.fm

Connection Blade GbE Switch/IBP 36/8+2 (SB11)36 internal 1-Gbit/s ports to the server blades8 external 1-Gbit/s ports through RJ45 connections2 external 10-Gbit/s ports through SFP+ modules via fiber-optic or copper cable1 internal stacking port to the midplane of the BX900 S2 system unit1 external stacking port through a CX4 connectionInstallable in all connection blade slotsI This connection blade can be used as a layer-2 switch or an

Intelligent Blade Panel (IBP).

The stacking ports allow up to 8 SB11 connection blades to be switched together to form a so-called stack, see the "PRIMERGY BX900 S2 System Unit Upgrade and Maintenance Manual".

1 Gb Ethernet connection blades in slots CB3/4 (fabric 2), CB5/6 (fabric 3) and CB7/8 (fabric 4) only support server blades that are fitted with an 1 Gb Ethernet mezzanine card.

Page 21: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 21

Functional overview

Connection Blade 10 GbE Switch/IBP 18/818 internal 10-Gbit/s ports to the server blades8 external 10-Gbit ports through SFP+ modules or active twinax cables (copper)Installable in all connection blade slots CB1/2 (fabric 1), CB3/4 (fabric 2) and CB5/6 (fabric 3)I This connection blade can be used as a layer-2 switch or an

Intelligent Blade Panel (IBP).

10 Gb Ethernet connection blades in slots CB3/4 (fabric 2) and CB5/6 (fabric 3) only support server blades that are fitted with corresponding 10 Gb or 1 Gb Ethernet mezzanine cards or 10 Gb CNA mezzanine cards.

The 18 internal ports are divided into 9 groups. Each port group is associated with two server blade slots on top of each other. The ports within a single group must use the same link protocol with either 10 Gbit/s or 1 Gbit/s link speed. Default link speed is 10 Gbit/s.

The management blade web interface allows the user to modify the link speed configuration for each port group, see the management blade online help.

For more information, see the operating manuals for the relevant server blades and the manual "PRIMERGY 10GbE Connection Blade 18/8 User Guide" and " スイッチブレード 10Gbps 18/8 取扱説明書 "(for the Japanese market).

Page 22: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

22 Operating Manual BX900S2

Functional overview

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

66-0

01.fm

Connection Blade Ethernet Pass Thru 10Gb 18/1818 internal 1/10-Gbit/s ports to the server blades18 external uplink ports at 10 Gbit/s and 1 Gbit/s link speed through SFP+/SFP modulesInstallable in connection blade slots CB1/2 (fabric 1), CB3/4 (fabric 2) and CB5/6 (fabric 3)I 10 Gb Ethernet Pass Thru connection blades in slots CB3/4

(fabric 2) and CB5/6 (fabric 3) only support server blades that are fitted with 1Gb or 10 Gb Ethernet mezzanine cards or 10Gb CNA mezzanine cards.

The 18 internal ports are divided into 6 groups. Each port group is associated with three server blade slots. The ports within a single group must use the same link protocol with either 10 Gbit/s or 1 Gbit/s link speed. Default link speed is 10 Gbit/s.

The management blade web interface allows the user to modify the link speed configuration for each port group, see the management blade online help.

Page 23: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 23

Functional overview

Fibre Channel connection blades

I Fibre Channel connection blades only support server blades that are fitted with a Fibre Channel mezzanine card.

Connection Blade 8Gb FC Switch 18/8 (Brocade BR5450)18 internal 8-Gbit/s ports to the server blades8 external ports through 8-Gb SFP+ modules or 4-Gb SFP modulesInstallable in slots CB3/4 (fabric 2) and CB5/6 (fabric 3)This connection blade is available in three license variants:

– Brocade 5450 with 14-port license – Brocade 5450 with 26-port license – Brocade 5450 with 26 port license and performance bundle

As the operating system for the 8 Gb FC Switch Connection Blade 18/8, the complete functional scope of Brocade Fabric OS, the shared software platform for Brocade Fibre Channel switches, is available. The FC switch blade is administered via Fabric Watch and Advanced Web Tools from Brocade.

Connection Blade 8Gb FC Pass Thru18/1818 internal 8-Gbit/s ports to the server blades18 external ports through 8-Gb SFP+ modules or 4-Gb SFP modulesInstallable in slots CB3/4 (fabric 2) and CB5/6 (fabric 3)

Page 24: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

24 Operating Manual BX900S2

Functional overview

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

66-0

01.fm

10 Gb Ethernet / DCB connection blades

Connection Blade DCB SW 10Gb 18/6+618 internal 10-Gbit/s ports to the server blades6 external 10-Gbit/s Data Center Bridging (DCB) capable ports through Brocade branded SFP+ modules or SFP+ Twinax cables6 external FC ports through 8-Gb SFP+ modules or 4-Gb SFP modulesInstallable in slots CB 1/2 (fabric 1), CB3/4 (fabric 2) and CB5/6 (fabric 3)I The connection blade DCB SW 10Gb 18/6+6 in slots CB3/4

(fabric 2) and CB5/6 (fabric 3) only supports server blades that are fitted with one of the following mezzanine cards:

– 10 Gbit CNA mezzanine card (MC-CNA102E)– 10 Gbit CNA mezzanine card (MC-CNA112E)– 10 Gbit Ethernet mezzanine card

Connection Blade FEX B22F 10Gb (Cisco)16 internal 10-Gbit/s ports to the server blades8 external 10-Gbit/s Ethernet ports for connection to the parent Cisco Nexus 5000 Series Switch through Cisco branded copper Twinax cables, Fabric Extender Transceivers (FET), or other standard 10 Gigabit Ethernet optics such as 10Gbase-SR, 10Gbase-LR, and 10Gbase-ERInstallable in slots CB 1/2 (fabric 1), CB3/4 (fabric 2) and CB5/6 (fabric 3)I The connection blade FEX B22F 10Gb (Cisco) in slots CB3/4

(fabric 2) and CB5/6 (fabric 3) only supports server blades that are fitted with one of the following mezzanine cards:

– 10 Gbit CNA mezzanine card (MC-CNA112E)– 10 Gbit Ethernet mezzanine card

Page 25: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 25

Functional overview

Infiniband connection blades

I Infiniband connection blades only support server blades that are fitted with an Infiniband mezzanine card.

SAS connection blade

I The SAS connection blade allows connection of multiple targets such as SX980 S1 and SX980 S2 storage blade and initiators. SAS connection blades only support server blades that are fitted with an SAS mezzanine card.

Connection Blade Infiniband Switch 40 Gb 18/1818 internal 40-Gbit/s ports to the server blades18 external 40-Gbit/s Infiniband connections through QSFP modulesInstallable in slots CB3/4 (fabric 2), CB5/6 (fabric 3) and CB7/8 (fabric 4)

I Connection Blades Infiniband Switch 40 Gb 18/18 only support server blades that are fitted with an 40 Gb Infiniband mezzanine card (PY IB CX2 Mezz Card 40Gb 2 Port).

Connection Blade Infiniband Switch 56 Gb 18/18 FDR18 internal 56-Gbit/s ports to the server blades18 external 56-Gbit/s Infiniband connections through QSFP modules1 external debug port through USB connectorInstallable in slots CB3/4 (fabric 2), CB5/6 (fabric 3) and CB7/8 (fabric 4)

I Connection Blades Infiniband Switch 56 Gb 18/18 FDR only support server blades that are fitted with an 56 Gb Infiniband mezzanine card (PY IB CX3 Mezz Card 56Gb 2 Port).

Connection Blade SAS Switch 6 Gb 18/618 internal 6-Gbit/s ports to the server blades6 external 6-Gbit/s SAS connectorsInstallable in slot CB5/6 (fabric 3)

Page 26: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

26 Operating Manual BX900S2

Functional overview

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

66-0

01.fm

The connection blades support hot-swapping. By installing two connection blades in two adjacent slots (not possible with Infiniband connection blades), you can provide redundant network connections for the server blades.

Information

For the latest information on optional products provided for the BX900 S2 system unit see the configurator of the system unit:

http://ts.fujitsu.com/products/standard_servers/index.html (for the EMEA market)

http://jp.fujitsu.com/platform/server/primergy/system/ (for the Japanese market)

Management blade

The PRIMERGY BX900 S2 system unit has slots for two redundant, hot-swap management blades with an integrated management solution for complete remote administration of the system.

Supported programsThe ServerView management blade is compliant with IPMI (Intelligent Platform Management Interface) 2.0. It supports schemes like FRU (Field Replaceable Units), SEL (System Event Log), SDR (Sensor Data Records) and the PDA (Prefailure Detection and Analysis) technology from Fujitsu. It also allows the configuration of a watchdog timer.

Communication with the server bladesThe ServerView management blade communicates with the server blades via an I2C bus. An IPMB interface is provided to support the user, when performing hardware monitoring tasks for the server blades.

Communication with the connection bladesTo enable communication with the connection blades, a CLI interface is provided. It allows to configure settings of the connection blades, such as the IP address, the IP mask, or the IP gateway address.

Hardware monitoringThe hardware monitoring functions provided by the ServerView management blade include:

– Monitoring temperature of each server blade via the IPMB interface

– Monitoring the status of the system fans

– Setting the system fans to an optimum speed

– Monitoring the status ot the power supply modules

Page 27: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 27

Functional overview

– Monitoring the temperature of the connection blades via the I2C bus

Event repositoryTo store messages on events that occur in the system environment, the ServerView management blade is equipped with an event repository, providing a 2 x 32 MB SDRAM.

Auto configurationThe management function auto configuration is used to back up system parameters to a ROM, which is located on the management blade. It also provides the possibility to restore these parameters if required. This reduces the risk if system configuration data have been corrupted or lost.

SSL (Secure Socket Layer)The Manager Blade provides SSL for network data privacy for Telnet as well as for HTTP connections.

The base configuration of the system unit contains one management blade. For more information on the management blade, see the manual "PRIMERGY BX900 Blade Server Systems ServerView Management Blade S1 User Interface Description".

Power supply

The system unit has six installation bays for hot-plug power supply units. There are two types of power supply units available, standard PSU and High Efficiency PSU (hereinafter referred to as HE PSU), see"Electrical data (standard PSU)" on page 31 and "Electrical data (HE PSU)" on page 31. Both types automatically set themselves to a voltage in the range of 100 - 240 V.

The base configuration includes three power supply units. As an option, you can set up a redundant power supply with three additional power supply units. If a power supply unit fails, the redundant configuration assures continued operation. The defective power supply unit can be replaced during operation (for further details see the "PRIMERGY BX900 S2 System Unit Upgrade and Maintenance Manual").

I A combination of standard PSUs and HE PSUs in one BX900 S2 system unit is not allowed.

Cooling

Cooling of the system is ensured by two fan units in each power supply unit and by the fan modules. Each of the fan units contains 2x2 fans. The fan modules have the same aspect ratio as the power supply units. Depending on the

Page 28: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

28 Operating Manual BX900S2

Functional overview

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

66-0

01.fm

number of installed server blades and storage blades in the system unit, empty power supply installation bays must be fitted with fan modules. The configuration is redundant and offers hot-swap functionality (for more information, see the "PRIMERGY BX900 S2 System Unit Upgrade and Maintenance Manual").

High level of availability and data security

Due to its fully redundant design (MMBs, NICs, Fans, PSUs) and in combination with ServerView Resource Coordinator Virtual Edition (RCVE) and the ServerView Resource Orchestrator (ROR), the PRIMERGY BX900 S2 can completely protect itself against any possible failure; at the same time it excels with the fastest automatic recovery, and with an allocation of its available resources to services, according to requirements.

Service and support

PRIMERGY servers are easy to maintain and modular, thus enabling quick and simple maintenance.

The handles and locks (touch point) used to exchange components are colored green to ensure simple and immediate recognition.

In order to prevent the components from being damaged by incorrect handling when they are being installed and removed, the areas of all components that can be touched without damaging them are also marked green.

Page 29: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 29

Functional overview

2.2 System unit specification

This section explains the specifications for the system unit. The specifications for this system unit are liable to be updated without any notice. Please be forewarned.

Interfaces (Management Blade)

Slots

Operating Panel

USB connectors 2 xSerial 1 (9-pin) 1 x serial RS-232-CManagement LAN (RJ-45)

Management LAN ports for blade server management (2 x 1 Gbit/s Ethernet)

Service LAN (RJ45) Dedicated Service LAN port for MMB (1 Gbit/s Ethernet)

Dual Server Blades or Storage Blades

18 x

Management Blades 2 xConnection Blades 8 x (2 per 4 fabrics)PSU 6 x

Operating buttons On/off buttonID button

Status LEDs ID indicator (blue)Power indicator (orange / green)Global Error indicator (orange)CSS indicator (yellow)

Service Display ServerView Local Service Display for Blade

Page 30: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

30 Operating Manual BX900S2

Functional overview

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

66-0

01.fm

Dimensions / Weight

Ambient conditions

Condensation during operation must be avoided!

Noise level

Dimensions 482.6 mm (Bezel) / 445 mm (Body) x 778 mm x 438 mmm

Height Unit Rack 10 UWeight Up to 204 kgWeight notes Weight may vary depending on actual configurationRack mounting kit Included

Environment class 3K2Environment class 2K2

EN 60721 / IEC 721 Part 3-3EN 60721 / IEC 721 Part 3-2

Temperature:Operation (3K2) 5°C .... 35°CTransport (2K2) -20°C .... 60°C

Humidity 10% .... 85% (non condensing)

Sound power level LWAd (ISO 9296) < 8.6 B (operation)Sound pressure level at adjacent workstationLpAm (ISO 9296)

< 64 dB (standby)< 79 dB (operation)

Page 31: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 31

Functional overview

Electrical data (standard PSU)

Electrical data (HE PSU)

Rated voltage range 100 - 240 V

Frequency 50 Hz - 60 Hz

Max. rated current 230 V / 11.6 A (EMEA market)100-120 V / 12 A (Japanese market)200-240 V / 13.5 A (Japanese market)

Effective power 3200 W (230 V) (EMEA market)1600 W (100 V) (EMEA market)2500 W (230 V) (Japanese market)1080 W (100 V) (Japanese market)

Apparent power 3265 VA (230 V) (EMEA market)1635 VA (100 V) (EMEA market)2550 VA (230 V) (Japanese market)1120 VA (100 V) (Japanese market)

Heat dissipation 11520 kJ/h (with 3200 W) (EMEA market)9000 kJ/h (with 2500 W) (Japanese market)5760 kJ/h (with 1600 W) (EMEA market)3999 kJ/h (with1080 W) (Japanese market)

Main power fuse 16 A

Protection class I

Rated voltage range 100 - 240 V

Frequency 50 Hz - 60 Hz

Max. rated current 230 V / 13.7 A100-120 V / 16 A200-240 V / 16 A (Japanese market)

Effective power 3160 W (230 V)1600 W (100 V)

Apparent power 3295 VA (230 V)1635 VA (100 V)

Heat dissipation 11376 kJ/h (with 3160 W)5760 kJ/h (with 1600 W)

Main power fuse 25 A

Protection class I

Page 32: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

32 Operating Manual BX900S2

Functional overview

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

66-0

01.fm

Compliance with regulations and standards

Product safety and ergonomicsInternational IEC 60950-1 2ed.Europe

Safety EN 60950-1 2ed.EN 50371EN 50392

Ergonomics ISO 9241-3EN 2941-3EK1-ITB 2003:2007

USA / Canada CSA-C22.2 No. 60950-1-07 2ed.UL 60950-1 2ed.

Taiwan CNS 14336China GB 4943

Electromagnetic compatibilityInternational CISPR 22Europe EN 55022 Class A

EN 55024EN 61000-3-2EN 61000-3-3ETSI 300386

USA / Canada 47CFR part 15 Class A / ICES-003Taiwan CNS 13438 Class AChina GB 9245 / GB 17625Japan VCCI Class A / JEITAKorea KN 22 / KN 24

CE marking to EU directives

Low Voltage Directive 2006/95/ECElectromagnetic compatibility 2004/108/EC

Page 33: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 33

3 Installation steps, overviewThis chapter provides an overview of the installation steps for your BX900 S2 system unit. Links take you to sections where you can find more detailed information about the respective steps:

Ê First of all, it is essential that you familiarize yourself with the safety information in chapter "Important information" on page 35.

Ê Unpack the system, check the delivery for damage sustained during transport and make sure it corresponds to the specifications in the delivery note (see section "Unpacking the system unit" on page 48).

Ê Make sure that all necessary manuals are available (see "Documentation overview" on page 8"); print out the PDF files if required.

Ê Install the system in the rack (see section "Installing/removing the system unit" on page 49 and configuration diagram on the order lists).

Ê Connect the cables (see section "Connecting devices to the system unit" on page 60). Please also read the section "Notes on connecting/disconnecting cables" on page 65.

Ê Connect the system to the mains (see section "Connecting the system unit to the mains" on page 61).

Ê Familiarize yourself with the control and display elements on the front and back of the system unit (see section "Control and display elements" on page 67).

Ê Install the server blades and storage blades in the slots on the front of the system unit (see the "PRIMERGY BX900 S2 System Unit Upgrade and Maintenance Manual").

Ê Install the connection blades in the slots on the back of the system unit (see the "PRIMERGY BX900 S2 System Unit Upgrade and Maintenance Manual").

Ê Configure the management blades (see section "Configuring management blades" on page 96) so that you can carry out all further administration of the system unit via LAN.

Ê Install the required operating systems and applications on the server blades. For information see the relevant operating manuals.

Page 34: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

34 Operating Manual BX900S2

Installation steps, overview

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

67-0

01.fm

Page 35: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 35

4 Important informationV CAUTION!

Before installing and starting up a device, please observe the safety instructions listed in the following section. This will help you to avoid making serious errors that could impair your health, damage the device and endanger the data base.

4.1 Safety instructions

I The following safety instructions are also provided in the manual "Safety Notes and Regulations" or " 安全上のご注意 ".

This device meets the relevant safety regulations for IT equipment. If you have any questions about whether you can install the server in the intended environment, please contact your sales outlet or our customer service team.

● The actions described in this manual shall be performed by technical specialists. A technical specialist is a person who is trained to install the server including hardware and software.

● Repairs to the device that do not relate to CSS failures shall be performed by service personnel. Please note that unauthorized interference with the system will void the warranty and exempt the manufacturer from all liability.

● Any failure to observe the guidelines in this manual, and any improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) or damage the equipment.

● Before installing/removing internal options to/from the server, turn off the server, all peripheral devices, and any other connected devices. Also unplug all power cords from the power outlet. Failure to do so can cause electric shock or damage.

Before starting up

● During installation and before operating the device, observe the instructions on environmental conditions for your device (see "Ambient conditions" on page 30).

● If the device is brought in from a cold environment, condensation may form both inside and on the outside of the device.

Page 36: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

36 Operating Manual BX900S2

Important information

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

68-0

01.fm

Wait until the device has acclimatized to room temperature and is absolutely dry before starting it up. Material damage may be caused to the device if this requirement is not observed.

● Transport the device only in the original packaging or in packaging that protects it from knocks and jolts.For the Japanese market, transporting the device in its original packaging does not apply.

Installation and operation

● This unit should not be operated in ambient temperatures above 35 °C.

● If the unit is integrated into an installation that draws power from an industrial power supply network with an IEC309 connector, the power supply's fuse protection must comply with the requirements for non-industrial power supply networks for type B connectors.

● The unit automatically adjusts itself to a mains voltage in a range of 100 - 240 V. Ensure that the local mains voltage lies within these limits.

● This device must only be connected to properly grounded power outlets or connected to the grounded rack internal power distribution system with tested and approved power cords.

● Ensure that the device is connected to a properly grounded power outlet close to the device.

● Ensure that the power sockets on the device and the properly grounded power outlets are easily accessible.

● The On/Off button or the main power switch (if present) does not isolate the device from the mains power supply. In case of repair or servicing disconnect the device completely from the mains power supply, unplug all power plugs from the properly grounded power outlets.

● Always connect the server and the attached peripherals to the same power circuit. Otherwise you run the risk of losing data if, for example, the server is still running but a peripheral device (e.g. memory subsystem) fails during a power outage.

● Data cables must be adequately shielded.

● Ethernet cabling has to comply with EN 50173 and EN 50174-1/2 standards or ISO/IEC 11801 standard respectively. The minimum requirement is a Category 5 shielded cable for 10/100 Ethernet, or a Category 5e cable for Gigabit Ethernet.

Page 37: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 37

Important information

● Route the cables in such a way that they do not create a potential hazard (make sure no-one can trip over them) and that they cannot be damaged. When connecting the server, refer to the relevant instructions in this manual.

● Never connect or disconnect data transmission lines during a storm (risk of lightning hazard).

● Make sure that no objects (e.g. jewelry, paperclips etc.) or liquids can get inside the server (risk of electric shock, short circuit).

● In emergencies (e.g. damaged casing, controls or cables, penetration of liquids or foreign bodies), contact the system administrator or your customer service team. Only disconnect the system from the mains power supply if there is no risk of harming yourself.

● Proper operation of the system (in accordance with IEC 60950-1 resp. EN 60950-1) is only ensured if the casing is completely assembled and the rear covers for the installation slots have been fitted (electric shock, cooling, fire protection, interference suppression).

● Only install system expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and those relating to telecommunication terminals. If you install other expansions, they may damage the system or violate the safety regulations. Information on which system expansions are approved for installation can be obtained from our customer service center or your sales outlet.

● The components marked with a warning notice (e.g. lightning symbol) may only be opened, removed or exchanged by authorized, qualified personnel. Exception: CSS components can be replaced.

● The warranty is void if the server is damaged during installation or replacement of system expansions.

● Only set screen resolutions and refresh rates that are specified in the operating manual for the monitor. Otherwise, you may damage your monitor. If you are in any doubt, contact your sales outlet or customer service center.

● Before installing/removing internal options to/from the server, turn off the server, all peripheral devices, and any other connected devices. Also unplug all power cords from the outlet. Failure to do so can cause electric shock.

● Do not damage or modify internal cables or devices. Doing so may cause a device failure, fire, or electric shock and will void the warranty and exempt the manufacturer from all liability.

Page 38: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

38 Operating Manual BX900S2

Important information

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

68-0

01.fm

● Devices inside the server remain hot after shutdown. Wait for a while after shutdown before installing or removing internal options.

● The circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity. To ensure reliable protection, if you are wearing an earthing band on your wrist when working with this type of module, connect it to an unpainted, non-conducting metal part of the system.

● Do not touch the circuitry on boards or soldered parts. Hold the metallic areas or the edges of the circuit boards.

● Install the screw removed during installation/detaching internal options in former device/position. To use a screw of the different kind can cause a breakdown of equipment.

● The installation indicated on this document is sometimes changed to the kind of possible options without notice.

Batteries

● Incorrect replacement of batteries may lead to a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer.

● Do not throw batteries into the trash can.

● Batteries must be disposed of in accordance with local regulations concerning special waste.

● Make sure that you insert the battery the right way round.

● The battery used in this device may present a fire or chemical burn hazard if mistreated. Do not disassemble, heat about 100 °C (212F), or incinerate the battery.

● All batteries containing pollutants are marked with a symbol (a crossed-out garbage can). In addition, the marking is provided with the chemical symbol of the heavy metal decisive for the classification as a pollutant:

Cd Cadmium Hg Mercury Pb Lead

Page 39: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 39

Important information

Working with optical disk drives and media

When working with optical disk drives, these instructions must be followed.

V CAUTION!

● Only use CDs/DVDs/BDs that are in perfect condition, in order to prevent data loss, equipment damage and injury.

● Check each CD/DVD/BD for damage, cracks, breakages etc. before inserting it in the drive.

Note that any additional labels applied may change the mechanical properties of a CD/DVD/BD and cause imbalance and vibrations.

Damaged and imbalanced CDs/DVDs/BDs can break at high drive speeds (data loss).

Under certain circumstances, sharp CD/DVD/BD fragments can pierce the cover of the optical disk drive (equipment damage) and can fly out of the device (danger of injury, particularly to uncovered body parts such as the face or neck).

● High humidity and airborne dust levels are to be avoided. Electric shocks and/or server failures may be caused by liquids such as water, or metallic items, such as paper clips, entering a drive.

● Shocks and vibrations are also to be avoided.

● Do not insert any objects other than the specified CDs/DVDs/BDs.

● Do not pull on, press hard, or otherwise handle the CD/DVD/BD tray roughly.

● Do not disassemble the optical disk drive.

● Before use, clean the optical disk tray using a soft, dry cloth.

● As a precaution, remove disks from the optical disk drive when the drive is not to be used for a long time. Keep the optical disk tray closed to prevent foreign matter, such as dust, from entering the optical disk drive.

● Hold CDs/DVDs/BDs by their edges to avoid contact with the disk surface.

Page 40: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

40 Operating Manual BX900S2

Important information

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

68-0

01.fm

● Do not contaminate the CD/DVD/BD surface with fingerprints, oil, dust, etc. If dirty, clean with a soft, dry cloth, wiping from the center to the edge. Do not use benzene, thinners, water, record sprays, antistatic agents, or silicone-impregnated cloth.

● Be careful not to damage the CD/DVD/BD surface.

● Keep the CDs/DVDs/BDs away from heat sources.

● Do not bend or place heavy objects on CDs/DVDs/BDs.

● Do not write with ballpoint pen or pencil on the label (printed) side.

● When a CD/DVD/BD is moved from a cold place to a warm place, moisture condensation on the CD/DVD/BD surface can cause data read errors. In this case, wipe the CD/DVD/BD with a soft, dry cloth then let it air dry. Do not dry the CD/DVD/BD using devices such as a hair dryer.

● To avoid dust, damage, and deformation, keep the CD/DVD/BD in its case whenever it is not in use.

● Do not store CDs/DVDs/BDs at high temperatures. Areas exposed to prolonged direct sunlight or near heating appliances are to be avoided.

I You can prevent damage from the optical disk drive and the CDs/DVDs/BDs, as well as premature wear of the disks, by observing the following suggestions:

– Only insert disks in the drive when needed and remove them after use.

– Store the disks in suitable sleeves.– Protect the disks from exposure to heat and direct sunlight.

Laser information

The optical disk drive complies with IEC 60825-1 laser class 1.

V CAUTION!

The optical disk drive contains a light-emitting diode (LED), which under certain circumstances produces a laser beam stronger than laser class 1. Looking directly at this beam is dangerous.

Never remove parts of the optical disk drive casing!

Page 41: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 41

Important information

Modules with Electrostatic-Sensitive Devices

Modules with electrostatic-sensitive devices are identified by the following sticker:

Figure 3: ESD label

When you handle components fitted with ESDs, you must always observe the following points:

● Switch off the system and remove the power plugs from the power outlets before installing or removing components with ESDs.

● The circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity. To ensure reliable protection, you must wear an earthing band on your wrist when working with this type of module and connect it to an unpainted, non-conducting metal part of the system.

● Any devices or tools that are used must be free of electrostatic charge.

● Wear a suitable grounding cable that connects you to the external chassis of the system unit.

● Always hold components with ESDs at the edges or at the points marked green (touch points).

● Do not touch any connectors or conduction paths on an ESD.

● Place all the components on a pad which is free of electrostatic charge.

I For a detailed description of how to handle ESD components, see the relevant European or international standards (EN 61340-5-1, ANSI/ESD S20.20).

Page 42: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

42 Operating Manual BX900S2

Important information

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

68-0

01.fm

Transporting the system unit

● Only transport the system unit in its original packaging or in suitable packaging which protects it from knocks and jolts. For the Japanese market, transporting the device in its original packaging does not apply.

Only unpack the system unit at the place where you want to set it up.

● Ask someone for help with carrying the system unit. Because the PRIMERGY BX900 S2 system unit is large and heavy, at least 3 people are needed.

● Before lifting the system unit, remove all server blades, storage blades, connection blades, management blades, all power supply units, fan modules and dummy modules units to reduce the weight.

● To lift or carry the system unit, mount the handles on the long sides of the unit.

● Only lift or carry the system unit by the handles on the long sides.

● Never lift or carry the system unit by the handles on the front or back.

Notes on installation into the rack

● For safety reasons, at least 3 people are required to install the system unit in the rack because of its weight and size.

(For the Japanese market, please refer to " 安全上のご注意 ".)

● Before lifting the system unit, remove all server blades, storage blades, connection blades, management blades, all power supply units, fan modules and dummy modules to reduce the weight.

● To lift or carry the system unit, always use the handles on the long sides.

● Never lift or carry the system unit by the handles on the front or back of the unit.

● For safety reasons, no more than one unit may be removed from the rack at any one time during installation or maintenance work.

● Make sure that the anti-tilt plate is correctly mounted when you set up the rack.

● The rack may tip over if more than one unit is removed at the same time.

Page 43: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 43

Important information

● Before connecting or disconnecting cables, read the notes in the chapter "Important Notes" in the technical manual for the relevant rack. The technical manual for the rack is supplied with the rack.

● The rack must be connected to the mains by an authorized specialist (electrician).

● If the server system is integrated in a rack installation that receives power from an industrial (public) power supply network with the IEC309 connector, the (public) power supply protection must comply with the requirements for the non-industrial (public) power supply networks for the type B connector.

● The power supply for the rack should be distributed over the three phases of a three-phase mains connection.

Other important information:

● During cleaning, observe the instructions in section "Cleaning the system unit" on page 102.

● Keep this operating manual and the other documentation (such as the technical manual, documentation DVD) close to the device. All documentation must be included if the equipment is passed on to a third party.

4.2 CE conformity

4.3 FCC Class A Compliance Statement

If there is an FCC statement on the device, it applies to the products covered in this manual, unless otherwise specified herein. The statement for other products will appear in the accompanying documentation.

The system complies with the requirements of the EC directives 2004/108/EC regarding "Electromagnetic Compatibility" and 2006/95/EC "Low Voltage Directive". This is indicated by the CE marking (CE = Communauté Européenne).

Page 44: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

44 Operating Manual BX900S2

Important information

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

68-0

01.fm

NOTE:

This equipment has been tested and found to comply with the limits for a "Class A" digital device, pursuant to Part 15 of the FCC rules and meets all requirements of the Canadian Interference-Causing Equipment Standard ICES-003 for digital apparatus. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in strict accordance with the instructions, may cause harmful interference to radio communications. However, there is no warranty that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

● Reorient or relocate the receiving antenna.

● Increase the separation between equipment and the receiver.

● Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

● Consult the dealer or an experienced radio/TV technician for help.

Fujitsu is not responsible for any radio or television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Fujitsu. The correction of interferences caused by such unauthorized modification, substitution or attachment will be the responsibility of the user.

The use of shielded I/O cables is required when connecting this equipment to any and all optional peripheral or host devices. Failure to do so may violate FCC and ICES rules.

WARNING:

This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

Page 45: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 45

Important information

4.4 Environmental protection

Environmentally-friendly product design and development

This product has been designed in accordance with the Fujitsu standard for "environmentally friendly product design and development". This means that key factors such as durability, selection and labeling of materials, emissions, packaging, ease of dismantling and recycling have been taken into account.

This saves resources and thus reduces the harm done to the environment. Further information can be found at:

– http://ts.fujitsu.com/products/standard_servers/index.html (for the EMEA market)– http://jp.fujitsu.com/platform/server/primergy/concept/ (for the Japanese

market)

Energy-saving information

Devices that do not need to be constantly switched on should be switched off until they are needed as well as during long breaks and after completion of work.

Packaging information

This packaging information doesn’t apply to the Japanese market.

Do not throw away the packaging. You may need it later for transporting the system. If possible, the equipment should only be transported in its original packaging.

Information on handling consumables

Please dispose of printer consumables and batteries in accordance with the applicable national regulations.

In accordance with EU directives, batteries must not be disposed of with unsorted domestic waste. They can be returned free of charge to the manufacturer, dealer or an authorized agent for recycling or disposal.

All batteries containing pollutants are marked with a symbol (a crossed-out garbage can). They are also marked with the chemical symbol for the heavy metal that causes them to be categorized as containing pollutants:

Cd CadmiumHg MercuryPb Lead

Page 46: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

46 Operating Manual BX900S2

Important information

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

68-0

01.fm

Labels on plastic casing parts

Please avoid sticking your own labels on plastic parts wherever possible, since this makes it difficult to recycle them.

Returns, recycling and disposal

Please handle returns, recycling and disposal in accordance with local regulations.

Details regarding the return and recycling of devices and consumables within Europe can also be found in the "Returning used devices" manual, via your local Fujitsu branch or from our recycling center in Paderborn:

Fujitsu Technology SolutionsRecycling CenterD-33106 Paderborn

Tel. +49 5251 525 1410Fax +49 5251 525 32 1410

The device must not be disposed of with domestic waste. This device is labeled in compliance with European directive 2002/96/EC on waste electrical and electronic equipment (WEEE).

This directive sets the framework for returning and recycling used equipment and is valid across the EU. When returning your used device, please use the return and collection systems available to you. Further information can be found at http://ts.fujitsu.com/recycling.

Page 47: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 47

5 Hardware installationV CAUTION!

● Follow the safety instructions in the chapter "Important information" on page 35.

● Do not expose the server to extreme environmental conditions (see "Ambient conditions" on page 30). Protect the server from dust, humidity and heat.

● Make sure that the server is acclimatized for the time indicated in this table before putting it into operation.

In the table "Acclimatization time", the temperature difference refers to the difference between the operating environment temperature and the temperature to which the server was exposed previously (outside, transport or storage temperature).

Temperature difference (°C) Minimum acclimatization time (hours)

5 310 515 720 825 930 10

Table 2: Acclimatization time

Page 48: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

48 Operating Manual BX900S2

Hardware installation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

69-0

01.fm

5.1 Unpacking the system unit

V CAUTION!

Make sure you observe the safety notes in chapter "Important information" on page 35.

The system unit must always be lifted or carried by at least three people. (For the Japanese market, please refer to " 安全上のご注意 ").

Only unpack the system unit at the place where you want to set it up.

Ê Unpack all the individual parts.

Keep the original packaging of the system unit, as you may need it for future transport (applies only to EMEA market).

Ê Check the delivery for any damage during transport.

Ê Check whether the items delivered match the details on the delivery note.

The product name and serial number of the product can be found on the ID card (see section "ID card" on page 72).

Ê If the delivery is damaged or does not match the delivery note, contact your supplier immediately!

Page 49: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 49

Hardware installation

5.2 Installing/removing the system unit

V CAUTION!

At least three people are needed to lift the system unit. (For the Japanese market, please refer to " 安全上のご注意 ".)

Additionally, a lifter is required in the following cases:

– The system unit weighs more than 50 kg.– The system unit weighs more than 21 kg and is to be installed above

the height of 25 U.

When using a lifter, this install/removal procedure needs to be carried out by maintenance personnel.

The rack may tip over if more than one unit is removed at the same time.

For configurations below 32 kg:

At least two people are needed to lift the system unit.

For configurations below 55 kg:

At least three people are needed to lift the system unit.

For configurations above 55 kg:

At least four people are needed to lift the system unit.

Page 50: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

50 Operating Manual BX900S2

Hardware installation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

69-0

01.fm

Please observe the safety information and notes on rack mounting in chapter "Important information" on page 35.

Fujitsu rack systems

The rack systems from Fujitsu support the installation of PRIMERGY servers:

– PRIMECENTER rack– PRIMECENTER M1 rack– DataCenter rack– 19-inch standard rack (for the Japanese market)– 19-inch slimline rack (for the Japanese market)

I For information on mounting the system unit in the rack please refer to the mounting instructions provided in this section. Further information you find in the manual of your rack system.

For the Japanese market, please refer also to the "Rack system structure guide.

I Online documentation for rack installation can be found on:

http://manuals.ts.fujitsu.com/index.php?id=5406-5605-5606 (for the EMEA market)

http://jp.fujitsu.com/platform/server/primergy/manual/peri_rack.html (for the Japanese market).

To accommodate the ventilation concept and ensure proper ventilation, any unused areas in the rack must be sealed using dummy covers.

The power is supplied via the multiple socket outlets fitted in the rack (for the EMEA market).

The main features of Fujitsu rack systems are as follows:

– support systems having a linear alignment feature to ensure that they can be adjusted to different rack depths

Asymmetrical PRIMECENTER Rack and DataCenter Rack provide an enhanced cable management in the lateral rack area.

3rd party racks

I Installation in most current rack systems from other manufacturers (3rd party racks) is also supported. For details please contact your sales representative.

Page 51: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 51

Hardware installation

5.2.1 Installation in PRIMECENTER/DataCenter rack

For installation in a PRIMECENTER/DataCenter rack, the following parts are required:

– One 10-HU support bracket (option for asymmetrical rack like PRIMECENTER/DataCenter rack)

– Two carrier rails (right and left rail) – Two holding-down clamps– Six M5 screws including plugwashers– Ten M5 centering screws– Four cage nuts

I – The descriptions and figures in this section refer to the current support system. For other support systems you will find the appropriate description in the packaging of the rack mounting kit.

– General information regarding server installation in the rack is included in the manual for the appropriate rack.

Positioning the system unit in the rack

The BX900 S2 system unit occupies 10 Height Units (HU) in the rack. The figure 4 and figure 5 show the position of the screws and cage nuts for securing the carrier rails, holding-down clamps and the system unit.

I The figures below refer to the symmetrical rack. There is no support bracket. The holding-down clamp and the carrier rail are installed directly on the support upright.

Page 52: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

52 Operating Manual BX900S2

Hardware installation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

69-0

01.fm

Figure 4: Position of the system unit in the rack - front support uprights

Position of M5 screws including plugwashers

Position of cage nuts

A Carrier rails

A A1

10

15

20

25

30

5

1

10

15

20

25

30

5

Page 53: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 53

Hardware installation

Figure 5: Position of the system unit in the rack - rear support uprights

Ê Clarify the position of the system unit in the rack.

Ê Mark the position of the bottom edge of the system unit on the support uprights.

Position of centering screws

Position of the insert knob

A Carrier railsB Holding-down clamps

A A

B B

1

10

15

20

25

30

5

1

10

15

20

25

30

5

Page 54: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

54 Operating Manual BX900S2

Hardware installation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

69-0

01.fm

When mounting the left carrier rail in the PRIMECENTER/DataCenter rack, the optional support bracket must first be mounted on the rear left support upright flush with the bottom edge of the device.

I The support bracket is not necessary for the symmetrical rack.

Ê Read the installation guide in the manual for the corresponding rack.

Ê Mark the position of the bottom edge of the system unit on the support uprights.

Figure 6: Attaching the support brackets

Ê Position the support bracket at the relevant height on the rear left support upright (place knob in the corresponding hole) and secure it using four centering screws.

Page 55: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 55

Hardware installation

Ê Fasten the holding-down clamp at the upper end of the support bracket using two centering screws, see (1) in figure 6.

I For the symmetrical racks:

The support bracket is not necessary for the symmetrical rack. Please position the holding-down clamp directly on the support upright.

Ê Fasten the second holding-down clamp at the same height as the first one to the rear right support upright using two centering screws.

Ê Identify the right and the left rail.

Figure 7: Attaching the left carrier rail

Ê Position the carrier rail in the support bracket (insert knob) - see (1).

I For the symmetrical racks:

The support bracket is not necessary for the symmetrical rack. There is no support bracket. Please position the support system directly on the support upright.

Page 56: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

56 Operating Manual BX900S2

Hardware installation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

69-0

01.fm

Ê Fasten the carrier rail at the lower end of the support bracket using three centering screws (2).

Ê Position the carrier rail in the front left support upright.

Ê Fasten the carrier rail to the front support upright (3) using three M5 screws including plugwashers.

Ê Repeat the operation for the right carrier rail. This rail does not require a support bracket.

Figure 8: Position of the cage nuts

Ê Fit the cage nuts for securing the system unit in the corresponding catches on the right and left support uprights.

1

5

10

15

20

25

13 13

27 27

Page 57: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 57

Hardware installation

5.2.2 Installing/removing the system unit

V CAUTION!

● Because the PRIMERGY BX900 S2 system unit is large and heavy, at least three people are needed to safely mount it in the rack or remove it from the rack.

● Please observe the safety information and notes on rack installation in the chapter "Important information".

● Before you install the system unit in the rack, remove all server blades, storage blades, connection blades, management blades, all power supply units, fan modules and dummy modules to reduce the weight of the system unit.

● Only lift or carry the system unit by the handles on the long sides.

● Never lift or carry the system unit by the handles on the front or back.

Ê Make a note of the positions of the individual server blades and storage blades, the connection blades, power supply units and fan modules in the system unit for reinstallation.

Ê Remove the server blades, storage blades, power supply units, fan modules, connection blades, management blades and dummy modules from the system unit. Removal of these components is described in the "PRIMERGY BX900 S2 System Unit Upgrade and Maintenance Manual".

I If there is no PRIMERGY BX900 S2 System Unit Upgrade and Maintenance Manual available on ServerView Suite DVD2, please refer to the following URL:

http://manuals.ts.fujitsu.com (for EMEA market)

http://jp.fujitsu.com/platform/server/primergy/manual/ (for Japanese market)

Page 58: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

58 Operating Manual BX900S2

Hardware installation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

69-0

01.fm

Figure 9: Placing the system unit on the rack rails

I Before inserting the system unit in the rack ensure the stability of the rack.

Ê Lift the back end of the system unit onto the carrier rails in the rack.

Ê Remove the back handles (both sides) on the side of the system (1).

Ê Push the system unit into the rack until just before the front pair of side handles (2).

2

Page 59: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 59

Hardware installation

Figure 10: Installing the system unit

Ê Remove the front two handles (both sides) on the side of the system (1).

Ê Push the system unit into the rack as far as it will go.

Ê Fasten the system unit to the rack using the four knurled screws.

Ê Reinstall the server blades, storage blades, connection blades and management blades, power supply units, fan modules and dummy modules in their old bays, see page 57. Installation of these components is described in the "PRIMERGY BX900 S2 System Unit Upgrade and Maintenance Manual".

V CAUTION!

Incorrect fitting of the system unit may lead to serious errors.

Removing the system unit

V CAUTION!

● Make a note of the positions of the individual server blades, storage blades, connection blades, power supply units and fan modules in the system unit for reinstallation.

To remove the system unit, follow the installation instructions in reverse.

Page 60: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

60 Operating Manual BX900S2

Hardware installation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

69-0

01.fm

5.3 Connecting devices to the system unit

On the back of the system unit are the ports for the network connection and the administration of the blade server.

Ports on the back of the system unit

Figure 11: Ports for external devices

CB 1 -8 Slots for connection blades. For information on the ports of the connection blades, see "Indicators and connectors of the connection blades" on page 78.

MMB 1, 2 The management blades have the following ports

1 Service LAN port (as a point-to-point connection, for system unit administration only, no access to server blades and connection blades)

2 USB ports for backing up and restoring the MMB configuration and for access to logging information

3 Serial port for a local management console

4,5 LAN ports for blade server management (including server blades and connection blades)

CB 2

CB 4

CB 6

CB 8

MMB 2

CB 1

CB 3

CB 5

CB 7

MMB 1

21

345

Page 61: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 61

Hardware installation

I The service LAN port (pos. 1 in figure 11 on page 60) and the LAN ports for blade server management (pos. 4 and 5 in figure 11 on page 60) must be in different LAN subnetworks.

It is recommended to operate the management blade user interface in a separate broadcast domain for the server management.

Ê Connect the data cables according to the system configuration you require.

Ports on the front of the system unit

On the front of the system unit are the ports of the server blades for local administration. For information on these, see the operating manuals for the relevant server blades.

5.3.1 Cable routing

The cables are routed along the support uprights of the rack.

5.4 Connecting the system unit to the mains

The system unit has six bays for hot-swap power supply units. In the base configuration, it is fitted with three power supply units.

V CAUTION!

● Read the information on determining how many power supply units are required (see the "PRIMERGY BX900 S2 System Unit Upgrade and Maintenance Manual").

● The power supply units automatically adjust to a mains voltage between 100 - 240 V. The system unit may only be used if the local mains voltage is within the voltage range of the system.

● The 2880 W power supply units may only be connected to 16 A power outlets, a UPS, a 32 A power distribution unit, or CEE sockets. When ordering the system unit, you must specify which socket type is available at the installation location, so that the cables with the appropriate C19 connectors can be supplied.

● For the Japanese market:The standard power supply units (Japanese version) may only be connected to NEMA L6-20, IEC 60320-C20, or NEMA 5-15 sockets.

Page 62: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

62 Operating Manual BX900S2

Hardware installation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

69-0

01.fm

The HE power supply units may only be connected to NEMA L6-20 or IEC 60320-C20 sockets.

● Always connect the cable first to the power supply unit and then to the mains.

Ê First connect the insulated C19 connector of the power cable to the power supply units of the system unit, and then plug the connector into the UPS, power distribution unit or an external socket.

AC source (phase) redundancy

Make sure that the individual power supply units are connected to different AC sources (phases). This ensures additional AC source (phase) redundancy for high-availability configurations. If only one AC source (phase) fails, the power supply units connected to the other AC sources (phases) remain operational.

Figure 12: Numbering of the power supply unit bays

Power system with 2 AC sources (phases) availableWith 6 power supply units, you must connect the ones in the top row (PSUs 1, 2 and 3) to the first source (phase) and the ones in the bottom row (PSUs 4, 5 and 6) to the second source (phase). Thus 3+3

PSU 1 PSU 2 PSU 3

PSU 4 PSU 5 PSU 6

Page 63: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 63

Hardware installation

redundancy is supported; the system continues to run if one source fails, provided the remaining 3 power supplies are sufficient to deliver the required power.

With 4 power supply units, you must connect units 2 and 3 to the first source (phase) and units 5 and 6 to the second. Thus 2+2 redundancy is supported; the system continues to run if one source fails, provided the remaining 2 power supplies are sufficient to deliver the required power.

Power system with 3 AC sources (phases) availableWith 6 power supply units, you must connect units 1 and 4 to the first AC source (phase), units 2 and 5 to the second, and units 3 and 6 to the third. Thus 4+2 redundancy is supported; the system continues to run if one source fails, provided the remaining 4 power supplies are sufficient to deliver the required power.

With 3 power supply units, you must connect each one to a different source. Thus 2+1 redundancy is supported; the system continues to run if one source fails, provided the remaining 2 power supply units are sufficient to deliver the required power.

Page 64: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

64 Operating Manual BX900S2

Hardware installation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

69-0

01.fm

5.4.1 Using cable ties

If you wish, you can secure the power cable with a cable tie to prevent the C19 connector from being pulled out of the server accidentally. The cable tie is included in the accessories pack that is delivered together with the server.

Figure 13: Using cable ties

Ê Route the cable through the loop of the cable tie.

Ê Pull the cable tie tight to secure the power cable.

The insulated connector cannot now be disconnected from the server accidentally.

I You can undo the cable tie by bending back the zip strip at the fastening point (1).

1

Page 65: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 65

Hardware installation

5.5 Notes on connecting/disconnecting cables

V CAUTION!

Always read the documentation supplied with the device you wish to connect.

Never connect, or disconnect cables during a thunderstorm.

Never pull on a cable when disconnecting it. Always take hold of the cable by the plug.

Follow the sequence described below to connect or disconnect external devices to or from the server:

Be sure to wait for 10 seconds or more after shutdown before turning the server on.

Connecting cables

Ê Turn off all power and equipment switches.

Ê Disconnect all power plugs from the properly grounded power outlets.

Ê Connect all cables to the server and peripherals.

Ê Plug all data communication cables into the utility sockets.

Ê Plug all power cords into the properly grounded power outlets.

Disconnecting cables

Ê Turn off all power and equipment switches.

Ê Disconnect all power plugs from the properly grounded power outlets.

Ê Unplug all data communication cables from the utility sockets.

Ê Disconnect the relevant cables from the server and all the peripherals.

I For connecting or disconnecting LAN cables, the server does not need to be powered off. To avoid loss of data teaming function has to be enabled.

Page 66: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

66 Operating Manual BX900S2

Hardware installation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

69-0

01.fm

Information for ensuring electromagnetic compatibility

All data and signal cables must have sufficient shielding. The use of cable type S/FTP Cat5 or better is recommended. Use of unshielded or badly shielded cables may lead to increased emission of interference and/or reduced fault-tolerance of the device.

Page 67: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 67

6 Starting up and operationV CAUTION!

Follow the safety instructions in chapter "Important information" on page 35.

6.1 Control and display elements

6.1.1 Front of system

The BX900 S2 system unit has a fold-out ServerView local service panel on the front. It is controlled by the management blade and is used for local diagnostics and administration of the blade server. It is also used for the initial configuration of the management blades, see "Configuring management blades" on page 96.

Figure 14: ServerView Local Service Panel

The most important control and display elements can also be found on the front of the ServerView local service panel. This means they are also available when it is folded away.

I The control and display elements of the server blades and storage blades are described in the relevant operating manuals.

Page 68: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

68 Operating Manual BX900S2

Starting up and operation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

70-0

01.fm

Figure 15: Locking the ServerView local service panel

V CAUTION!

Press the touch point (see arrow) of the ServerView local service panel before you push it back into the frame of the system unit.

Page 69: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 69

Starting up and operation

Figure 16: Control and display elements on the front of the ServerView local service panel

1 CSS indicator 5 Power indicator2 Global Error indicator 6 ID indicator3 ID button 7 Navigation buttons for the

LocalView menu system4 On/Off button

1 2 3 4 5 6 7

Page 70: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

70 Operating Manual BX900S2

Starting up and operation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

70-0

01.fm

6.1.1.1 Control elements

6.1.1.2 LEDs on the control panel

On/Off button

When the system is switched off, it can be switched on again by pressing the On/Off button.

When the system is operating, pressing the On/Off button will switch off the system.

V CAUTION!

Risk of loss of data!

I The On/Off button does not disconnect the server from the mains voltage. To disconnect from the mains completely, remove the power plug(s).

ID ID button

Lights up (blue) on the front and on the rear of the system unit when the ID button is pressed. The two ID indicators are synchronized.

Navigation buttons for the LocalView menu system

With the buttons , , and you select a function. Pressing the button executes the selected function.

Power indicator (two-color)

Lights up green when the system unit is switched on.

Lights up orange when the system unit is switched OFF, but mains voltage is present (standby mode).

Page 71: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 71

Starting up and operation

Global Error indicator (orange)

– Lights up orange if a prefailure event has been detected that requires (precautionary) service intervention.

– Flashes orange if an error was detected that requires service intervention.

– Does not light up if there is no critical event.

If the event is still acute after a power cycle, the indicator is activated after the restart.

The indicator also lights up in standby mode.

You can find more details on the indicated errors in the System Event Log (SEL), in the Management Blade Web interface, on the ServerView Local Service Panel, on the ServerView Local Service Display, in the ServerView Operations Manager or via the iRMC S2/S3's Web interface.

CSS CSS indicator (yellow)

– Lights up yellow if a prefailure event was detected for a CSS component that you can fix yourself (for reasons of precaution) with the CSS concept.

– Flashes yellow if an error was detected that you can fix yourself with the CSS concept.

– Does not light up when the system is OK.

If the event is still acute after a power cycle, the indicator is activated after the restart.

The indicator also lights up in standby mode.

For more information on the CSS concept, see "Customer Self Service (CSS)" on page 11.

ID ID indicator (blue):

Glows blue when the system was selected by pressing the ID button. Pressing the button again deactivates the LED.

The ID indicator can also be activated via the Management Blade Web interface and via the ServerView Operations Manager and the iRMC S2/S3 Web interface and its status reported to the ServerView Operations Manager and the iRMC S2/S3.

!

Page 72: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

72 Operating Manual BX900S2

Starting up and operation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

70-0

01.fm

6.1.1.3 ID card

You can pull out the ID card (see figure 17) as far as it will go and push it back in again.

Figure 17: ID card in system unit

The ID card contains various system information, such as the product name, serial number and order number.

Page 73: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 73

Starting up and operation

6.1.2 Back of system

6.1.2.1 Control and display elements on the management blade

Figure 18: Control and display elements on the management blade

1 Status indicator (yellow)Lights up when the management blade is active (master)Blinks when the management blade is defective.Is not lit when the management blade is not active (slave)

2 LAN link indicators (service LAN port)Lights up green if a LAN connection exists.Does not light up if no LAN connection exists.

3 LAN activity indicators (service LAN port)Flashes yellow for a LAN transfer is in progress.Does not light up for no LAN transfer.

1 2 3 4 5 6 7 8 9 10 11

Page 74: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

74 Operating Manual BX900S2

Starting up and operation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

70-0

01.fm

4 Global Error indicator (orange)

– Lights up orange if a prefailure event has been detected that requires (precautionary) service intervention.

– Flashes orange if an error was detected that requires service intervention.

– Does not light up if there is no critical event.

If the event is still acute after a power cycle, the indicator is activated after the restart.

The indicator also lights up in standby mode.

You can find more details on the indicated errors in the System Event Log (SEL), in the Management Blade Web interface, on the ServerView Local Service Panel, on the ServerView Local Service Display, in the ServerView Operations Manager or via the iRMC S2/S3's Web interface.

5 CSS indicator (yellow)

– Lights up yellow if a prefailure event was detected for a CSS component that you can fix yourself (for reasons of precaution) with the CSS concept.

– Flashes yellow if an error was detected that you can fix yourself with the CSS concept.

– Does not light up when the system is OK.

If the event is still acute after a power cycle, the indicator is activated after the restart.

The indicator also lights up in standby mode.

For more information on the CSS concept, see "Customer Self Service (CSS)" on page 11.

6 Identification (ID) button with ID indicator (blue)

ID indicators on the front and rear of the server light up when the ID button is pressed. The two ID indicators are synchronized. To deactivate, press the button again.

The ID indicator can also be activated via ServerView Operations Manager and the Management Blade Web interface; its status is reported to ServerView Operations Manager and the Management Blade.

Page 75: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 75

Starting up and operation

7, 9 LAN link indicators (Management LAN ports)Lights up green if a LAN connection exists.Does not light up if no LAN connection exists.

8, 10 LAN activity indicators (Management LAN ports)Flashes yellow when a LAN transfer is in progress.Does not light up if no LAN transfer.

11 Reset button

Page 76: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

76 Operating Manual BX900S2

Starting up and operation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

70-0

01.fm

6.1.2.2 Indicators on the hot-plug power supply units

Figure 19: Indicators on the hot-plug standard power supply unit

Figure 20: Indicators on the hot-plug HE power supply unit

1 Error indicator for fan module 1 (orange)Lights up if fan module 1 is defective.

2 Mains power indicator (two-color)Flashes green when the system unit is switched off but still connected to the mains (standby mode).Lights up green when the system unit is switched on and is working properly.Lights up yellow when a prospective error has been detected in the power supply unit but the latter is still active.*

123

1

23

Page 77: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 77

Starting up and operation

6.1.2.3 Indicators on the hot-plug fans

Figure 21: Indicators on the hot-plug fan module

3 Error indicator for fan module 2 (orange)Lights up if fan module 2 is defective.

* The following events are detected as predictable errors:

The temperature is very high.The power consumption is very high.The current strength is very high.

1 Error indicator for fan module 1 (orange)Lights up if fan module 1 is defective.

2 Power indicatorFlashes green when the system unit is switched off but still connected to the mains (standby mode).Lights up green when the system unit is switched on and the fan module is working properly.

3 Error indicator for fan module 2 (orange)Lights up if fan module 2 is defective.

1 2 3

Page 78: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

78 Operating Manual BX900S2

Starting up and operation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

70-0

01.fm

6.1.3 Indicators and connectors of the connection blades

6.1.3.1 Connection Blade GbE Switch/IBP 18/6 (SB6)

Figure 22: Connection Blade GbE Switch/IBP 18/6

1 Status indicator (green/orange)

Lights up green: Power supply is supplied to the connection blade

Lights up orange:

Switch error

Dark: Power supply is not supplied to the connection blade

2 ID indicator (blue)

Lit: ID indicator was activated via the management blade

Dark: Normal operation

A 1-Gbit Ethernet ports (RJ45 with two integrated LAN status LEDs each)

3 LAN transfer rate (green/orange)

Lights up orange:

LAN transfer rate 1 Gbit/s

Lights up green: LAN transfer rate 100 Mbit/s

Dark: LAN transfer rate 10 Mbit/s

4 LAN connection indicator (green)

Lit: LAN connection available

Flashes: LAN connection active

Dark: LAN connection unavailable or deactivated

1 2 3 4

A

Page 79: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 79

Starting up and operation

6.1.3.2 Connection Blade GbE Switch/IBP 36/12 (SB11A)

Figure 23: Connection Blade GbE Switch/IBP 36/12

1 ID indicator (blue)

Lit: ID indicator was activated via the management blade

Dark: Normal operation

2 Status indicator (green/orange)

Lights up green: power supply is supplied to the connection blade.

Dark: power supply is not supplied to the connection blade.

Lights up orange:

Switch error

Dark: Power supply interrupted

A 1-Gbit Ethernet ports for SFP modules for connecting fiber-optic or copper cables (4x, with two integrated status LEDs each)

3 (ERR) Error indicator (orange)

Dark: No SFP+ transceiver error

Lit: SFP transceiver error

Flashes: SFP module not supported

4 (LINK) LAN connection indicator (green)

Lit: SFP transceiver connection available

Flashes: SFP transceiver connection active

Dark: SFP transceiver connection not available or deactivated

1 2

3 4 5 6

A B

Page 80: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

80 Operating Manual BX900S2

Starting up and operation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

70-0

01.fm

B 1-Gbit Ethernet ports (8x, RJ45 with two integrated LAN status LEDs each)

5 LAN transfer rate (green/orange)

Lights up orange:

LAN transfer rate 1 Gbit/s

Lights up green: LAN transfer rate 100 Mbit/s

Dark: LAN transfer rate 10 Mbit/s

6 LAN connection indicator (green)

Lit: LAN connection available

Flashes: LAN connection active

Dark: LAN connection unavailable or deactivated

Page 81: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 81

Starting up and operation

6.1.3.3 Connection Blade GbE Switch/IBP 36/8+2 (SB11)

Figure 24: Connection Blade GbE Switch/IBP 36/8+2

1 Status indicator (green/orange)

Lights up green: Power supply is supplied to the connection blade

Flashes orange: Connection blade error

Dark: Power supply is not supplied to the connection blade

2 ID indicator (blue)

Lit: ID indicator was activated via the management blade

Dark: Normal operation

3 Stacking port 1 (internal) (green)

Lit: Stacking port 1 is available

Flashes green: Stacking port 1 is active

Dark: Stacking port 1 is not available

4 Stacking port 2 (external) (green)

Lit: Stacking port 2 is available

Flashes green: Stacking port 2 is active

Dark: Stacking port 2 is not available

5 Stacking (green/orange)

Lights up yellow:

Connection blade is stack master

Flashes yellow: Connection blade cannot perform role of master

Lights up green: Connection blade is stack slave

Flashes green: Master selection process is active

Dark: Connection blade does not belong to a stack

1 2 3 4 5 6 7 8 9

A B C

Page 82: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

82 Operating Manual BX900S2

Starting up and operation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

70-0

01.fm

A HiGig/HiGig+ connection (CX4) for stacking (2x), for detailed information see the "PRIMERGY BX900 S2 System Unit Upgrade and Maintenance Manual"

B 10-Gbit Ethernet ports for SFP+ modules for connecting fiber-optic or copper cables (with two integrated status LEDs each)

6 (ERR) Error indicator (orange)

Dark: No SFP+ transceiver error

Lit: SFP+ transceiver error

Flashes: SFP+ module not supported

7 (LINK) LAN connection indicator (green)

Lit: SFP+ transceiver connection available

Flashes: SFP+ transceiver connection active

Dark: SFP+ transceiver connection not available or deactivated.

C 1-Gbit Ethernet ports (RJ45 with two integrated LAN status LEDs each)

8 LAN transfer rate (green/orange)

Lights up orange:

LAN transfer rate 1 Gbit/s

Lights up green: LAN transfer rate 100 Mbit/s

Dark: LAN transfer rate 10 Mbit/s

9 LAN connection indicator (green)

Lit: LAN connection available

Flashes: LAN connection active

Dark: LAN connection unavailable or deactivated

Page 83: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 83

Starting up and operation

6.1.3.4 Connection Blade 10 GbE Switch/IBP 18/8

Figure 25: Connection Blade 10 GbE Switch/IBP 18/8

1 Status indicator (green/orange)

Lit green: Power supply is supplied to the connection blade

Flashes alternately green/orange:

Connection blade error

Dark: Power supply is not supplied to the connection blade

2 Stack indicator (green/yellow) (future use)

Lit yellow: Operating as a stack master

Flashes yellow: Operating failure as a stack master

Lit green: Operating as a stack slave

Flashes green Operating failure as a stack slave or during master election process

Dark: No stacking

3 ID indicator (blue)

Lit: ID indicator was activated via the management blade

Dark: Normal operation

6 Reset button

1 2 3 4 5

A 6

Page 84: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

84 Operating Manual BX900S2

Starting up and operation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

70-0

01.fm

A 10-Gbit Ethernet ports for SFP+ modules for connection of fiber-optic cables or for active twinax copper cables (8x, each with two integrated status LEDs)

4 (ERR) Error indicator (orange)

Dark: No SFP+ module error or SFP+ module not installed

Lit: SFP+ module error

Flashes: SFP+ module not supported

5 (LINK) LAN connection indicator (green)

Lit: LAN connection available

Flashes: LAN connection active

Dark: LAN connection unavailable or deactivated

Page 85: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 85

Starting up and operation

6.1.3.5 Connection Blade Ethernet Pass Thru 10Gb 18/18

Figure 26: Connection Blade Ethernet Pass Thru 10Gb 18/18

1 ID indicator (blue)

Lit: ID indicator was activated via the management blade

2 Status indicator (green/orange)

Lit green: Power is supplied to the connection blade

Flashes orange: Connection blade error

Dark: Power is not supplied to the connection blade

3 Status indicators for Ethernet ports (green/orange)

Dark: Occurs in the following cases:

– Server blade not present, powered down, or link is inactive– Uplink port module not present– Uplink port cable not connected– One or both of the internal and/or external links is down

Lit green: Both the internal and external links are up

Flashes orange: Occurs in the following cases:

– Link protocol mismatch (one indicator flashes orange)– Internal port speed configuration error (all indicators of all

ports in a port group flash together, see the "PRIMERGY BX900 S2 System Unit Upgrade and Maintenance Manual")

Flashes green: Link is up and data transfer

A External ports (18x)

Ports for Ethernet through SFP/SFP+ modules

1 2

A

A3

Page 86: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

86 Operating Manual BX900S2

Starting up and operation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

70-0

01.fm

6.1.3.6 Connection Blade 8Gb FC Switch 18/8

Figure 27: 8-Gb FC Switch Connection Blade 18/8

1ID

ID indicator (blue)

Lit: ID indicator was activated via the management blade

2 Health indicator (green/orange)

Controlled by the management blade

3 Reset button

4 Status indicator (green/orange)

Dark: Connection blade is not running or is defective

Lights up green: Connection blade is running

Lights up orange: Boot phase; one or more ports are offline; restarting connection

Flashes orange/green:

Warning: An error has occurred.

The LED can also flash during a test.

A External FC ports (8x)

Ports for FC SFP Multi-Mode (MMF) or FC SFP+ Multi-Mode (MMF) SFP modules

B Status indicators for external FC ports (green/orange)

Dark: No signal reception

Flickers green: FC port online, data transport

Flashes green: – Slow: FC port online, but segmented– Fast: Internal loop

Lights up orange: Signal reception, but not online

Flashes orange: Slow (~ 2 sec. interval): FC port deactivated.

Fast (~ 0.5 sec. interval): FC port defective

C Management LAN port

1 2 3 CA

B

4

Page 87: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 87

Starting up and operation

6.1.3.7 Connection Blade 8Gb FC Pass Thru 18/18

Figure 28: 8-Gb FC Pass Thru Connection Blade 18/18

1ID

ID indicator (blue)

Lit: ID indicator was activated via the management blade

2 Status indicator (green/orange)

Dark: Connection blade is powered off

Lights up green: Connection blade is powered on, status OK

Flashes orange: Connection blade is powered on, status fail

3 Status indicators for external FC ports (green)

Lit: FC link up

A, B External FC ports (A: 1-12, B: 13-18, from left to right)

Ports for FC SFP Multi-Mode (MMF) 4Gbit/s or FC SFP+ Multi-Mode (MMF) 8Gbit/s

1 2 3

A

B

Page 88: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

88 Operating Manual BX900S2

Starting up and operation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

70-0

01.fm

6.1.3.8 Connection Blade DCB SW 10Gb 18/6+6

Figure 29: Connection Blade DCB SW 10Gb 18/6+6

A External 10 Gb Ethernet ports (6x)

Ports for Brocade branded Ethernet SFP+ 10 Gbit/s modules or SFP+ Twinax cables

B External 8 Gb FC ports (6x)

Ports for Brocade branded FC SFP+ 8Gbit/s modules or SFP 4Gbit/s modules

1 Status indicators for external Ethernet ports (green/orange)

Dark: No signal carrier

Lights up green: Link is established and port is active. Online is normal, but no port activity.

Flickers green: Port online, data transport

Flashes green: – Slow: Port online, but segmented– Fast: Internal loop

Lights up orange: Port with no sync (light or signal carrier issue)

Flashes orange: Slow (~ 2 sec. interval): Port deactivated.

Fast (~ 0.5 sec. interval): Port defective

2 Status indicators for external FC ports (green/orange)

Dark: No signal carrier

Lit green: Link is established and port is active. Online is normal, but no port activity.

Flickers green: Port online, data transport

Flashes green: – Slow: Port online, but segmented– Fast: Internal loop

Lights up orange: Port with no sync (light or signal carrier issue)

Flashes orange: Slow (~ 2 sec. interval): Port deactivated.

Fast (~ 0.5 sec. interval): Port defective

1

3 4 5 6

A B

2

Page 89: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 89

Starting up and operation

3ID

ID indicator (blue)

Lit: ID indicator was activated via the management blade

4 Health indicator (green/orange)

Dark: Connection blade is powered off or power has failed

Lights up green: Connection blade is running

Flashes orange Connection blade has failed

5 Status indicator (green/orange)

Dark: Connection blade is shut down and powered off normally

Lights up green: Connection blade is running

Flashes green Boot phase; connection blade is running diagnostics and initialization programs

Flashes orange: Warning: Critical failures have occured (e.g. The temperature has risen the normal thermal threshold. The switch continues operating.)

Lights up orange: Warning: Fatal failures have occured. (Serious problem detected; the switch is powered off.)

6 Reset button

Press the reset button for up to five seconds to reboot the connection blade

Page 90: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

90 Operating Manual BX900S2

Starting up and operation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

70-0

01.fm

6.1.3.9 Connection Blade FEX B22F 10Gb (Cisco)

Figure 30: Connection Blade FEX B22F 10Gb (Cisco)

A External 10GbE ports (8x) to connect to the Nexus parent switch

Ports for Cisco branded copper Twinax cables, Fabric Extender Transceivers (FET), or other standard 10 Gigabit Ethernet optics such as 10Gbase-SR, 10Gbase-LR, and 10Gbase-ER

B Service port (only for diagnostic purposes)

1ID

ID indicator (blue)

Lit: ID indicator was activated via the management blade

2 Status indicator (green)

Dark: Connection blade is not running or is defective

Lights up green: Connection blade is running

3 Status indicators for external ports (green/orange)

Dark: No signal reception

Lights up green: Link is established

Lights up orange: Port is administratively disabled.

Flashes orange: Port is defective.

1 2

A B

3

Page 91: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 91

Starting up and operation

6.1.3.10 Connection Blade Infiniband Switch 40 Gb 18/18

Figure 31: Connection Blade Infiniband Switch 40 Gb 18/18

1 Status indicator (green/yellow)

Lights up green: Power supply is supplied to the connection blade

Flashes yellow: Switch error

2ID

ID indicator (blue)

Lit: ID indicator was activated via the management blade

3P

Physical link status indicator of the external IB ports (green)

Dark: No signal reception (IB port offline)

Lights up green: IB port online

4L/A

Logical link status indicator of the external IB ports (yellow)

Dark: No signal reception

Lights up yellow: IB port online

Flashes yellow: Data transport

A External IB ports (18x)Ports for QSFP plugs

3 4

12

A

Page 92: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

92 Operating Manual BX900S2

Starting up and operation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

70-0

01.fm

6.1.3.11 Connection Blade Infiniband Switch 56 Gb 18/18 FDR

Figure 32: Connection Blade Infiniband Switch 56 Gb 18/18 FDR

1 Status indicator (green/yellow)

Lights up green: Power supply is supplied to the connection blade

Flashes yellow: Switch error

2 ID indicator (blue)

ID Lit: ID indicator was activated via the management blade

3 Physical link status indicator of the external IB ports (green)

P Dark: No signal reception (IB port offline)

Lights up green: IB port online

4 Logical link status indicator of the external IB ports (yellow)

L/A Dark: No signal reception

Lights up yellow: IB port online

Flashes yellow: Data transport

A External IB ports (18x) Ports for QSFP plugs

B External Debug port

43

12

A AB

Page 93: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 93

Starting up and operation

6.1.3.12 Connection Blade SAS Switch 6 Gb 18/6

Figure 33: Connection Blade SAS Switch 6 Gb 18/6

1 Status indicator (green/orange)

Lights up green: Power supply is supplied to the connection blade

Lights up orange:

Switch error

Dark: Power supply is not supplied to the connection blade

2 ID indicator (blue)

Lit: ID indicator was activated via the management blade

Dark: Normal operation

3 Reset button

A 6-Gbit SAS connectors (6x)

1 2 3

A

Page 94: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

94 Operating Manual BX900S2

Starting up and operation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

70-0

01.fm

6.2 Switching the system unit on/off

V CAUTION!

● Before switching the system unit on using the On/Off button, the PRIMERGY BX900 S2 system unit must be connected to the power supply for at least a minute.

● If you switch on the system unit and the connected monitor only shows flickering stripes, switch it back off immediately (see chapter "Troubleshooting and tips" on page 105).

● The On/Off button does not disconnect the device from the mains. To fully disconnect it from the mains, you must unplug the plugs from the sockets.

● Turn the server on when the temperature is in its operating environment range (10 ~ 35°C). For details on the operating environment, refer to "Safety Precautions". When operating the device outside of this operating environment, the server may operate improperly, damage data etc. Furthermore, Fujitsu cannot be held responsible for any related damage, malfunction, or loss of data, etc.Be sure to wait for 10 seconds or more after shutdown before turning the server on.After connecting power cable, press the On/Off button after it passes for more than 10 seconds.

Switching on the system unit

Ê Press the On/Off button on the system unit (position 4 in figure 16 on page 69) for 2 seconds. Depending on the BIOS setting, the individual server blades will also be switched on. This is done in sequence according to the numbering of the server blade slots (see figure 1 on page 12.)

Ê If necessary, switch on the required server blades

The system unit is switched on and the activated server blades perform a system test and boot the operating system.

Switching off the system unit

The system unit is up and running (server blades are also switched on).

Ê To properly shut down all server blades, press the On/Off button on the front of the system unit (position 4 in figure 16 on page 69) for 4 seconds. All server blades will then be shut down.

Page 95: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 95

Starting up and operation

Ê To immediately shut down all server blades, press the On/Off button on the front of the system unit (position 4 in figure 16 on page 69) for 10 seconds. All server blades are switched off immediately.

Other ways to shut down the system unit

– Web interface of the management blade

You can also switch off the system unit and the individual server blades via the Web interface of the management blade (see manual "PRIMERGY BX900 Blade Server Systems ServerView Management Blade S1 User Interface Description").

– After power failure

After a power failure, the system unit will switch itself on again automatically, and the server blades which were running prior to the power failure are automatically started up again according to the BIOS setting.

I How to switch server blades on/off is described in the relevant operating manuals.

Page 96: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

96 Operating Manual BX900S2

Starting up and operation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

70-0

01.fm

6.3 Configuring management blades

The two redundant management blades form the central interface for administration of the system unit and all components therein. This section explains how to do the initial configuration of the management blades.

For more information on administration of the blade server, see the manual "PRIMERGY BX900 Blade Server Systems ServerView Management Blade S1 User Interface Description".

Initial configuration with the Base Configuration Wizard

Ê Make sure that the hardware installation of the system unit as described in chapter "Hardware installation" on page 47.

Ê Press the On/Off button on the ServerView local service panel (position 4 in figure 16 on page 69) to switch on the system unit.

The management blade boots and the ServerView local service panel shows the start menu of the Base Configuration Wizard.

Figure 34: Base Configuration Wizard start menu

Ê Select YES with the navigation buttons and press the button to start the wizard.

The NO button closes the Base Configuration Wizard, and the Health Status Overview menu is displayed.

Page 97: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 97

Starting up and operation

The wizard guides you step by step through the menus, in which you make the necessary settings for putting the blade server into operation. You operate the wizard with the Previous, Next, and Cancel buttons. The Finish button closes it. However, you cannot close the wizard until you have defined the following default settings:

– Language– Date/Time– Identification– Network

Language Defines the language for the menu (English or Japanese)Date/Time Contains the date, time and the time zone and

activates/deactivates summer time.

Date and Time Settings:

– Date:– Time:– Time Zone:– Daylight Saving Time enabled

Import Import Settings (1)

– Import System Unit settings from USB memory device

– Select the settings to be imported

– Language– Identification– Network– PIN– Power

Click Next and specify the path and file name of the configuration file on the USB storage medium.

Page 98: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

98 Operating Manual BX900S2

Starting up and operation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

70-0

01.fm

Ident. Identification Settings (1)

Assign a name for the chassis.

– System Name

Assign a name for the rack where the chassis resides.

– Rack Name

Identification Settings (2)

Assign a contact person for the system.

– SystemContact

Designate where the system resides.

– System Location

Page 99: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 99

Starting up and operation

Network If DHCP is activated (default), the obtained network data is displayed. Otherwise you can specify the network data manually:

Management LAN Settings (1)IPv4 settings

– IP Address is assigned by DHCP– Assign IP Address manually:

– IP Address– Subnet Mask– Gateway

Management LAN Settings (2)IPv4 settings

– Obtain DNS Config. from DHCP– Assign primary and secondary Domain Servers

– DNS Server 1– DNS Server 2

Management LAN Settings (3)IPv6 settings

– IPv6 is enabled– Obtain IP Address from DHCP

– IP Address

Management LAN Settings (4)IPv6 settings

– Obtain DNS Config.. from DHCP– Assign DNS Server manually:

– 1:– 2:

Page 100: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

100 Operating Manual BX900S2

Starting up and operation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

70-0

01.fm

Power Power Settings

Assign the Power Supply Redundancy Mode and the Dynamic Mode.

– PSU Redundancy (No Redundancy)– PSU Dynamic Mode (ON)

Power Settings (2)

If required specify the Power Consumption Budget.

– PSU Consumption Budget enable– Current Consumption Budget

– Power [W]– Ratio [%]

PIN PIN Setting

If required define a PIN number to protect the LC Display against unauthorized access.

– PIN enable (OFF)– PIN (0000)

Check Ekeying Check: This is a function which allows you to query the compatibility of the modules before startup, and then activate, partially activate or deactivate the module depending on the result. For example, you would not activate modules whose operating voltages or power consumption are not compatible with the system.

This test begins automatically after switch-on or after a hardware replacement. If errors are found, you can find out more about them via the Details button. Replace the defective hardware component and repeat the test.

Ekeying Check

The Ekeying Check will check the System Unit for mismatching hardware components.

Ekeying Errors:

– n/m*– Details

* n = number of mismatches, m = number of missings

Page 101: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 101

Starting up and operation

Save Clicking the Save button saves and applies the settings in the management blade.

With the Previous button you can go back and change parameters. You save the changed configuration with the Save button.

Save Settings

All necessary configurations are done. Do you really want to save your setting?

– Save

Export Stored settings can be saved on a USB storage medium. In the next menu you can specify which configuration data you want to save to the USB storage medium.

You can export the following parameters:

– Language– Identification– Network– PIN– Power

Export Settings

Do you like to export it on a USB memory device?

– Export Settings

Page 102: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

102 Operating Manual BX900S2

Starting up and operation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

70-0

01.fm

6.4 Cleaning the system unit

V CAUTION!

To clean the system unit, first switch it off and unplug the power plug(s) from the grounded power outlet(s).

The housing interior of the system unit should only be cleaned by authorized, qualified personnel.

Do not use abrasive powder or detergents which dissolve plastic to clean the housing exterior.

Make sure that no liquid gets inside the device and that the ventilation slits on the system unit remain open.

Clean the keyboard and the mouse with a disinfecting cloth.

You may clean the housing surface of the system unit with a dry cloth. If it is very dirty you can use a damp cloth that has been dipped in water with a mild detergent and well wrung out.

Page 103: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 103

7 Property and data protectionThe blade server is protected against unauthorized access by the lockable rack door.

To protect the system and data internally against unauthorized access, you can activate the security functions of the management blade. For more information, see the manual "PRIMERGY BX900 Blade Server Systems ServerView Management Blade S1 User Interface Description".

Further security options can be set in the BIOS setups and in the operating systems of the server blades. For information on these, see the BIOS Setup Utility for Reference Manuals or the operating manuals for the server blades.

Page 104: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

104 Operating Manual BX900S2

Property and data protection

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

71-0

01.fm

Page 105: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 105

8 Troubleshooting and tipsV CAUTION!

Follow the safety instructions in the "Safety notes and regulations" manual or " 安全上のご注意 " and in chapter "Important information" on page 35.

If a fault occurs, attempt to resolve it using the measures described:

– in this chapter,– in the documentation for the connected devices,– in the help systems of the software used.

If you fail to correct the problem, proceed as follows:

Ê Make a list of the steps performed and the circumstances that led to the fault. Also make a list of any error messages that were displayed.

Ê Switch off the server.

Ê Contact our customer service team.

8.1 System power indicator does not light up

The system's power indicator (see figure 16 on page 69) does not light up after you have switched on your system:

Power cable not connected correctly

Ê Make sure that the power cable is correctly connected to the system's power supply units and to the socket strip of the rack (see section "Connecting the system unit to the mains" on page 61).

Power supply overloaded

Ê Unplug the power cables from the insulated sockets of the power supply units.

Ê Wait a few seconds and then plug the power cables back into the sockets.

Ê Switch on your system.

Page 106: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

106 Operating Manual BX900S2

Troubleshooting and tips

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

72-0

01.fm

8.2 Front or back error LED flashes orange

If the front or back ID/error LED is flashing orange (see section "Control and display elements" on page 67), one of the following errors may have occurred:

One of the power supply units has failed

The status LED of the power supply unit is not lit and/or the error LED of the power supply unit flashes green if, for example, one of the following errors has occurred in the power supply unit (see also section "Indicators on the hot-plug power supply units" on page 76):

– General failure (warning or shutdown due to fan no. 1)– Temperature exceeded (one of the fans in the power supply unit is not

working properly)– Overcurrent– Overvoltage or undervoltage– The power supply unit is reaching the end of its life or its ambient thresholds

are being exceeded.

Ê Check the status of the power supply unit and/or the fan-failure LEDs to identify the defective module and replace it (see the "PRIMERGY BX900 S2 System Unit Upgrade and Maintenance Manual").

One of the fans in the fan module has failed

Although the system can still be used if one of the fans in the fan module fails, you should:

Ê Replace the defective fan module as soon as possible (see the "PRIMERGY BX900 S2 System Unit Upgrade and Maintenance Manual").

A connection blade has failed

The error LED of the connection blade lights up when a general error occurs.

Ê Check the error LEDs of the connection blades to find out which blade has failed.

Ê If the connection blade is still being shown as defective, replace it (see the "PRIMERGY BX900 S2 System Unit Upgrade and Maintenance Manual").

Page 107: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

BX900S2 Operating Manual 107

Troubleshooting and tips

8.3 System switches itself off

Server Management has detected an error

Ê Check the error list of System Event Log in ServerView Operations Manager or in the management blade web interface, and attempt to eliminate the error.

Page 108: PRIMERGY BX900 S2 Blade Server - Fujitsumanuals.ts.fujitsu.com/file/10617/bx900s2-om-en.pdf · Operating Manual - English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual

108 Operating Manual BX900S2

Troubleshooting and tips

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

2 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

WA

LTE

R\O

BJ_

DO

KU

-135

72-0

01.fm