2

Systems for pressure monitoringThe optimum solution for every requirement

Pressure sensors with displayfor industrial applications

Pressure sensorsfor mobile applications

Pressure sensors withanalogue displayfor hygienic applications

Pressure sensors with displayfor hygienic applications

Accessories

Pressure sensors without displayfor industrial applications

Page 4: Pressure sensors from ifm 2016

3

Ind

ust

rial

app

licat

ion

s w

ith

dis

pla

y

Mo

bile

app

licat

ion

s

Hyg

ien

icap

plic

atio

ns

wit

han

alo

gu

e d

isp

lay

Hyg

ien

icap

plic

atio

ns

wit

hd

isp

lay

Acc

esso

ries

4 - 7

Ind

ust

rial

app

licat

ion

sw

ith

ou

t d

isp

lay

8 - 11

12 - 13

14 - 15

16 - 17

18 - 19

PN -1...600 -25...80

PT / PU 0...600 -40...125

PA -1...600 -25...90

PK -1...400 -25...80

PT / PU -1...600 -40...90

PS 0...1 0...60

PV 0...400 -25...80

PG24 -1...400 -25...80

PQ -1...10 0...60

Senso

r typ

e

Mea

surin

g range [

bar]

Med

ium

tem

perat

ure [°

C]

Display

IO-L

ink

Hydra

ulic ap

plicat

ions

Mac

hine t

ools

Hygien

ic ar

eas

Mobile

applic

atio

ns

Wat

er-b

ased

med

ia

Gases

Viscous m

edia

and m

edia

with

susp

ended

par

ticles

Hydro

static

leve

l mea

sure

men

t

Applications

PI -1...25 -25...125 /200

PG27/28 -1...25 -25...125

Page 5: Pressure sensors from ifm 2016

Unambiguous:Red / green colour change for the display (type PQ) or pointerdisplay with LED ring (type PG).

Simple:Setting via sensor menu or viaIO-Link (type PQ3).

Flexible:Analogue output, switching output and IO-Link (type PQ3).

4

For industrialapplications

Type PG pressuresensor

Optimum legibilitydue to the electro-nic pointer display.

Rotatable displaywith LED bargraph for switchpoint indication.

Display of thetrend or of the minimum and maximum values.

Output functionsprogrammable via LED displayand optical touchfields.

Factory settingmeasuring rangerelative pressure

[bar]

Process connection

G 1/2 maleOrder no.

0...400 PG2450

0...250 PG2451

0...100 PG2452

0...25 PG2453

0...10 PG2454

0...4 PG2455

0...2,5 PG2456

-1...1 PG2409

0...1 PG2457

0...0.25 PG2458

0...0.1 PG2489

1 switching output and1 analogue output 4...20 mA / 20...4 mA, scalable

Page 6: Pressure sensors from ifm 2016

Type PQ pressuresensor

Ideal for measur -ing compressedair.

Two-colour LEDdisplay for immediate statusdetection.

Moisture-proof silicon measuringcell.

Easy installationusing integratedmounting holesand accessories.

IO-Link (typePQ3xxx).

Pressure sensors with displayfor industrial applications

AccessoriesProcessadapterspages 18 - 19

5

Measuring rangerelative pressure

[bar]

Order no.Measuring rangerelative pressure

[bar]

2 switching outputs DC PNPrelative pressure

Order no.

1 switching output and 1 ana-logue output 4...20 mA, relativepressure, differential pressure

-1...10 PQ7834In

du

stri

alap

plic

atio

ns

wit

hd

isp

lay

Mo

bile

app

licat

ion

s

Hyg

ien

icap

plic

atio

ns

wit

han

alo

gu

e d

isp

lay

Hyg

ien

icap

plic

atio

ns

wit

hd

isp

lay

Acc

esso

ries

Ind

ust

rial

app

licat

ion

sw

ith

ou

t d

isp

lay

-1...1 PQ7809

-1...10 PQ3834

-1...1 PQ3809

Page 7: Pressure sensors from ifm 2016

6

Type PN pressuresensor

Programmable2-colour display,clearly visibleswitch-point LEDs.

Captive laser typelabel.

IO-Link.

Robust:The ideal measuring cell forevery pressure range.

Red - green ranges:“Good ranges” or switchingstates can be identified quicklyvia the display colour.

Quick setting:Easy to use via 3 pushbuttons.

Optimum orientation:Process connection rotatable byapprox. 345°.

Universal application areas:High overload protection andprotection rating IP67 in pressureranges of -1...600 bar.

For industrialapplications

Factory settingmeasuring rangerelative pressure

[bar]

Process connection

G 1/4 female

Order no.

G 1/4 male

Order no.

G 1/4 female

Order no.

G 1/4 male

Order no.

Process connection

2 switching outputs 1 switching output and1 analogue output4...20 mA / 0...10 V

Measuring cell metal

0...600 PN7160 PN7560 PN3160 PN3560

Measuring cell ceramics

0...100 PN7092 PN7592 PN3092 PN3592

0...25 PN7093 PN7593 PN3093 PN3593

0...10 PN7094 PN7594 PN3094 PN3594

0...2.5 PN7096 PN7596 PN3096 PN3596

0...1 PN7097 PN7597 PN3097 PN3597

0...0.25

-1...1 PN7099 PN7599

-1...0 PN3129 PN3529

-0.5...0.5

0...400 PN7070 PN7570 PN3070 PN3570

0...250 PN7071 PN7571 PN3071 PN3571

Page 8: Pressure sensors from ifm 2016

7

Pressure sensors with displayfor industrial applications

Ind

ust

rial

app

licat

ion

s w

ith

dis

pla

y

Mo

bile

app

licat

ion

s

Hyg

ien

icap

plic

atio

ns

wit

han

alo

gu

e d

isp

lay

Hyg

ien

icap

plic

atio

ns

wit

hd

isp

lay

Acc

esso

ries

Ind

ust

rial

app

licat

ion

sw

ith

ou

t d

isp

lay

AccessoriesProcessadapterspages 18 - 19

G 1/4 female

Order no.

G 1/4 male

Order no.

Process connection

2 switching outputsor 1 switching output

and 1 analogue output4...20 V / 0...10 V,

scalable

PN2160 PN2560

PN2092 PN2592

PN2093 PN2593

PN2094 PN2594

PN2096 PN2596

PN2097 PN2597

PN2098 PN2598

PN2099 PN2599

PN2169 PN2569

PN2070 PN2570

PN2071 PN2571

Page 9: Pressure sensors from ifm 2016

Type PA pressuretransmitter

Pressure transmit-ters with fixedmeasuring range.

High resistance tooverload due toceramic measuringcell.

Space-saving:Compact sensors without display.

Simple:Pressure transmitters with fixedranges; pressure sensors to beset via setting ring (type PK) orvia IO-Link (type PV).

Focussed:Ideal for industrial applications,such as hydraulic applications.

AccessoriesProcessadapterspages 18 - 19

8

For industrialapplications

Measuring rangerelative pressure

[bar]

Process connection

G 1/4 female

Order no.

G 1/4 male

Order no.

G 1/4 female

Order no.

Analogue output 4...20 mA 0...10 V

0...600 PA3060 PA9060

0...400 PA3020 PA9020

0...250 PA3021 PA3521 PA9021

0...100 PA3022 PA3522 PA9022

0...25 PA3023 PA3523 PA9023

0...10 PA3024 PA3524 PA9024

0...2.5 PA3026 PA3526 PA9026

-1...1 PA3509

-1...0 PA3029 PA9029

0...1 PA3027 PA9027

0...0.25 PA3028 PA3528 PA9028

0...0.1 PA3589

Page 10: Pressure sensors from ifm 2016

Type PK pressuresensor

Easy switch pointadjustment viatwo setting ringsallowing optimumread-out.

Mechanical lockingprevents inadver-tent switch pointmanipulation.

Stainless steelmeasuring cellwithout any seals.

Pressure sensors without displayfor industrial applications

9

Ind

ust

rial

app

licat

ion

s w

ith

dis

pla

y

Mo

bile

app

licat

ion

s

Hyg

ien

icap

plic

atio

ns

wit

han

alo

gu

e d

isp

lay

Hyg

ien

icap

plic

atio

ns

wit

hd

isp

lay

Acc

esso

ries

Ind

ust

rial

app

licat

ion

sw

ith

ou

t d

isp

lay

Measuring rangerelative pressure

[bar]

2 x NO 1 x NO 2 switching outputs NC / NOcomplementary

Order no. Order no. Order no.

0...400 PK7520 PK5520 PK6520

0...250 PK7521 PK5521 PK6521

0...100 PK7522 PK5522 PK6522

0...25 PK7523 PK5523 PK6523

0...10 PK7524 PK5524 PK6524

Type PV pressuresensor

Programmablepressure sensorwith switchingoutputs.

Stainless steelmeasuring cellwithout any seals.

IO-Link.

Measuring rangerelative pressure

[bar]

2 switching outputs

Order no.

0...400 PV7000

0...250 PV7001

0...100 PV7002

0...60 PV7023

0...25 PV7003

0...10 PV7004

Available as of December 2016

Page 11: Pressure sensors from ifm 2016

Compact:Pressure transmitters withoutdisplay and with analogueoutput.

Robust:Stainless steel measuring cellwithout any seal.

Application-specific:Designs for level measurement(type PS), absolute pressuremeasurement (type PT05) andgeneral pressure measurement(type PT / PU).

10

Type PSsubmersible pres-sure transmitter

For level measure-ment.

PUR or FEP cablefor high resistanceto media.

Version withATEX approval forgroup I cat. M1and group II cat.1G and 1D.

Pressure compen-sation via inter nally vented cable.

Measuring rangerelative pressure

[mbar]

Cable

[m]

Order no.

For standard applications, CE approval

0.25 PUR, 5 PS3208

For high resistance to media, CE approval

0.25 FEP, 5 PS4208

For hazardous areas, CE, Ex, GL approvals

0.25 FEP, 5 PS308A

0.6 FEP, 10 PS307A

1 FEP, 15 PS317A

0.25 FEP, 10 PS4408

0.6 FEP, 10 PS4407

0.6 FEP, 20 PS4506

1 FEP, 15 PS4417

1 FEP, 30 PS4607

0.6 PUR, 10 PS3407

0.6 PUR, 15 PS3427

0.6 PUR, 30 PS3607

1 PUR, 15 PS3417

1 PUR, 30 PS3617

For industrialapplications

Type PU / PT pres-sure transmitter

Pressure transmit-ters with fixedmeasuring range.

Very fast responsetime of 1 ms.

Stainless steelmeasuring cellwithout any seal.

Page 12: Pressure sensors from ifm 2016

Pressure sensors without displayfor industrial applications

11

Ind

ust

rial

app

licat

ion

s w

ith

dis

pla

y

Mo

bile

app

licat

ion

s

Hyg

ien

icap

plic

atio

ns

wit

han

alo

gu

e d

isp

lay

Hyg

ien

icap

plic

atio

ns

wit

hd

isp

lay

Acc

esso

ries

Ind

ust

rial

app

licat

ion

sw

ith

ou

t d

isp

lay

Measuring rangerelative pressure

[bar]

Order no. Order no.

Analogue output 4...20 mA 0...10 V

0...600 PU5460

0...400 PU5400

0...250 PU5401

0...160 PU5412

0...100 PU5402

0...60 PU5423

PT5460

PT5400

PT5401

PT5412

PT5402

PT5423

0...40 PU5443PT5443

0...25 PU5403PT5403

0...16 PU5414PT5414

0...10 PU5404PT5404

0...6 PU5415PT5415

-1...10 PT5494

Type PT pressuretransmitter

For absolutepressure measure-ment.

Transmitter withfixed measuringrange.

Stainless steelmeasuring cellwithout any seal.

Measuring rangeabsolute pressure

[bar]

Order no.

0...10 PT0504

0...4 PT0505

0...1.6 PT0517

0...1 PT0507

Analogue output 4...20 mA

AccessoriesProcessadapterspages 18 - 19

Page 13: Pressure sensors from ifm 2016

Compact:Pressure transmitters withoutdisplay and with analogueoutput.

Robust:Stainless steel measuring cellwithout any seal; shock andvibration resistance.

Flexible:Deutsch, AMP or M12 connector.

Temperature-resistant:-40…125 °C medium temperature.

Fast:Response time 2 ms.

Application-specific:Ideal for use in mobile hydraulicapplications.

12

Systems formobile machines

Type PU / PTpressure trans-mitter

For mobileapplications.

Processconnection

Measuring rangerelative pressure

[bar]

Order no. Order no. Order no.

Analogue output 4...20 mA

M12 DEUTSCH AMP

G 1/4 male

0...600 PT5560 PT5760 PT5660

Analogue output 0...10 V

G 1/4 male

0...600 PU5560 PU5760 PU5660

0...400 PU5500 PU5700 PU5600

0...250 PU5501 PU5701 PU5601

0...100 PU5502 PU5702 PU5602

0...25 PU5503 PU5703 PU5603

0...10 PU5504 PU5704 PU5604

0...400 PT5500 PT5700 PT5600

0...250 PT5501 PT5701 PT5601

0...100 PT5502 PT5702 PT5602

0...25 PT5503 PT5703 PT5603

0...10 PT5504 PT5704 PT5604

Page 14: Pressure sensors from ifm 2016

13

Ind

ust

rial

app

licat

ion

s w

ith

dis

pla

y

Mo

bile

app

licat

ion

s

Hyg

ien

icap

plic

atio

ns

wit

han

alo

gu

e d

isp

lay

Hyg

ien

icap

plic

atio

ns

wit

hd

isp

lay

Acc

esso

ries

Ind

ust

rial

app

licat

ion

sw

ith

ou

t d

isp

lay

Pressure sensors without displayfor mobile applications

AccessoriesProcessadapterspages 18 - 19

Technical data

and prices?

www.ifm.com

Page 15: Pressure sensors from ifm 2016

Hygienic:Ingress resistance, materials andapprovals comply with hygienicrequirements.

Robust:Overload-resistant ceramic-capacitive measuring cells withlong-term stability.

Versatile:Variable process connections.

Precise:High total accuracy of 0.2 %.

Suitable for CIP/SIP:High temperature resistance andelectronic temperature compen-sation.

For hygienic areasand viscous media

Type PGpressure sensor

Optimum legibilitydue to the electro-nic pointer display.

Rotatable displaywith LED bargraph for switchpoint indication.

Display of thetrend or of theminimum andmaximum values.

Output functionsprogrammablevia LED displayand optical touchfields.

14

Factory settingmeasuring rangerelative pressure

[bar]

Process connection

G 1 male Aseptoflex VarioOrder no.

G 1 A sealing coneOrder no.

0...25 PG2793 PG2893

0...10 PG2794 PG2894

0...4 PG2795 PG2895

0...2.5 PG2796 PG2896

-1...1 PG2799 PG2899

0...1 PG2797 PG2897

0...0.25 PG2798 PG2898

0...0.1 PG2789 PG2889

1 switching output and1 analogue output 4...20 mA / 20...4 mA, scalable

Page 16: Pressure sensors from ifm 2016

Ind

ust

rial

app

licat

ion

s w

ith

dis

pla

y

Mo

bile

app

licat

ion

s

Hyg

ien

icap

plic

atio

ns

wit

han

alo

gu

e d

isp

lay

Hyg

ien

icap

plic

atio

ns

wit

hd

isp

lay

Acc

esso

ries

Ind

ust

rial

app

licat

ion

sw

ith

ou

t d

isp

lay

Pressure sensors with analogue displayfor hygienic applications

15

Order now?

In the e-shop at

www.ifm.com

AccessoriesProcessadapterspages 18 - 19

Page 17: Pressure sensors from ifm 2016

Hygienic:Ingress resistance, materials andapprovals comply with hygienicrequirements.

Robust:Overload-resistant ceramic-capacitive measuring cells withlong-term stability.

Versatile:Variable process connections.

Precise:High total accuracy of 0.2 %.

Suitable for CIP/SIP:High temperature resistance andelectronic temperature compen-sation.

For hygienic areasand viscous media

16

Factory settingmeasuring rangerelative pressure

[bar]

Process connection

G 1 male Aseptoflex VarioOrder no.

G 1 A sealing coneOrder no.

0...25 PI2793 PI2893

1 switching output and 1 analogue output 4...20 mA / 20...4 mA

0...10 PI2794 PI2894

0...4 PI2795 PI2895

0...2.5 PI2796 PI2896

-1...1 PI2799 PI2899

0...1 PI2797 PI2897

0...0.25 PI2798 PI2898

0...0.1 PI2789 PI2889

Factory settingmeasuring rangerelative pressure

[bar]

Process connection

Clamp 1.5"Order no.

Clamp 2"Order no.

0...25 PI2203 PI2303

0...10 PI2204 PI2304

0...4 PI2205 PI2305

0...2.5 PI2206

PI2209

PI2306

-1...1 PI2309

PI22070...1 PI2308

Type PI pressuresensor

Programmableanalogue outputin 2-wire opera-tion.

Additionalswitching out-put in 3/4-wireoperation.

IO-Link.

PI type pressuretransmitter

Pressure trans-mitters with clampprocess connection.

For mediumtemperaturesup to 200 °C.

1 switching output and 1 analogue output 4...20 mA / 20...4 mA

Page 18: Pressure sensors from ifm 2016

Ind

ust

rial

app

licat

ion

s w

ith

dis

pla

y

Mo

bile

app

licat

ion

s

Hyg

ien

icap

plic

atio

ns

wit

han

alo

gu

e d

isp

lay

Hyg

ien

icap

plic

atio

ns

wit

hd

isp

lay

Acc

esso

ries

Ind

ust

rial

app

licat

ion

sw

ith

ou

t d

isp

lay

Pressure sensors with displayfor hygienic applications

17

Order now?

In the e-shop at

www.ifm.com

AccessoriesProcessadapterspages 18 - 19

Page 19: Pressure sensors from ifm 2016

G 1/4 G 1/4 high-grade stainless steel (316L/1.4404) FKM

PN, PAwith

internalthread

E30143

Deviceconnection

Processconnection

Material For sensortype

Orderno.

Process adapters

G 1/4 G 1/2 stainless steel (303/1.4305), FPM (Viton) E30050

G 1/4 G 1/2 stainless steel (303/1.4305), FPM (Viton) E30000

G 1/4 G 1/2 high-gr. stainl. steel (316L/1.4404) FPM (Viton) E30002

G 1/4 M20 x 1.5 stainless steel (303/1.4305), FPM (Viton) E30010

G 1/4 SAE 7 / 16-20 high-gr. stainl. steel (316L/1.4404) FPM (Viton) E30087

G 1/4 1/4" NPT high-grade stainless steel (316Ti/1.4571) E30058

G 1/4 1/2" NPT high-grade stainless steel (316L/1.4404) E30133

G 1/4 DN16 stainless steel (304/1.4301) E30065

G 1/4 R 1/4 1.0718 (12L13) E30427

Accessories

For industrialapplications

For hygienic areasand viscous media

18

Adapters for industrial applications

Damping screw

PN

E30419

Description For sensortype

Order no.

Accessories for industrial applications

Protective cover E30420

Angle bracket E30421

Label tag E30422

PN, PK, PA35xxDamping screw for sensors with M5 internal thread E30057

Syphon G 1/4 E30140

Syphon G 1/2 E30141

PKProtective cover E30094

PS

Cable clamp fastener E30399

Filter element E30400

Splitter box with ventilation and terminal block E30401

Additional weight E30402

PQ

Connector QS-G 1/8-6 for tube with Ø 6 mm E30076

Connector QS-G 1/8-8 for tube with Ø 8 mm E30077

DIN rail clip E37340

Adapter R 1/8 - R 1/8 rotatable E37350

IO-Link interface E30396

Parameter setting tools

USB IO-Link master E30390

Memory plug, parameter memory for IO-Link sensors E30398

LINERECORDER SENSOR (USB stick) QA0001

G 1/4 G 1/2 high-grade stainless steel (316Ti/1.4571),FPM (Viton) E30135

Sensorswith G 1/4"

externalthread

Page 20: Pressure sensors from ifm 2016

Deviceconnection

Processconnection

Sealing Order no.with leakage port

For sensortype

Order no.Process adapters

Process adapters and mounting accessoriesfor pressure sensors

19

Ind

ust

rial

app

licat

ion

s w

ith

dis

pla

y

Mo

bile

app

licat

ion

s

Hyg

ien

icap

plic

atio

ns

wit

han

alo

gu

e d

isp

lay

Hyg

ien

icap

plic

atio

ns

wit

hd

isp

lay

Acc

esso

ries

Ind

ust

rial

app

licat

ion

sw

ith

ou

t d

isp

lay

High-grade stainless steel adapter (316L / 1.4435) for hygienic applications

G 1 maleAseptoflex

Vario

Clamp 1 - 1.5"Sealing ring

PG27xx,PI27xx

G 1 male sealing cone

PG28xx,PI28xx

E33201 E33208

Clamp 1 - 1.5" Metal-to-metal E33601 –

Pipe fittingDN40 (1.5") Metal-to-metal E33612 –

Varivent type NDN40...DN150

(1.5...6") D = 68Metal-to-metal E33622 –

Metal-to-metal E33701 –

High-grade stainless steel welding adapters for hygienic applications

G 1 maleAseptoflex

Vario

Welding adapterD50 Sealing ring PG27xx,

PI27xx

G 1 malesealing cone

Welding adapterD50

PG28xx,PI28xx

E30122 E30130

Metal-to-metal E30013 –

Sealing ring E30072 –

Adapter accessories for hygienic applications

G 1 maleAseptoflex

Vario

Sealing plug Sealing ringPG27xx,PI27xx

G 1 malesealing cone Sealing plug PG28xx,

PI28xx

E30128 –

FKM O-ring E30123

PEEK ring E30124

E30070

Clamp 2"Sealing ring E33202 E33209

Metal-to-metal E33702 –

Pipe fittingDN32 (1.25")

Sealing ring E33211 –

Metal-to-metal E33711 –

Pipe fittingDN40 (1.5")

Sealing ring E33212 –

Metal-to-metal E33712 –

Pipe fittingDN50 (2")

Sealing ring E33213 –

Metal-to-metal E33713 –

Varivent type FDN25 (1") D = 50

Sealing ring E33221 E33228

Metal-to-metal E33721 –

Varivent type NDN40...DN150

(1.5...6") D = 68

Sealing ring E33222 E33229

Metal-to-metal E33722 –

SMS DN40 (1.5") Metal-to-metal E33731 –

SMS DN50 (2") Metal-to-metal E33732 –

DRD flange D65 Sealing ring E33242 –

Universal adapterRd 52 Sealing ring E33340 –

DIN11864DN/OD33.7 Sealing ring E33304 –

G 1/2 Sealing ring E30131 –

Want to find

the suitable socket?

www.ifm.com

AdapterAccessories

Page 21: Pressure sensors from ifm 2016

Visit our website:

www.ifm.com

ifm electronic gmbhFriedrichstraße 145128 EssenTel. +49 / 201 / 24 22-0Fax +49 / 201 / 24 22-1200E-mail [email protected]

Over 70 locations worldwide –at a glance at www.ifm.com

Position sensors

Sensors formotion control

Industrial imaging

Safety technology

Process sensors

Condition monitoringsystems

Industrialcommunication

Identification systems

Systems formobile machines

Connectiontechnology

Overviewifm product range:

Accessories

ifm a

rtic

le n

o. 7

8001

977

· We

rese

rve

the

right

to

mak

e te

chni

cal a

ltera

tions

with

out

prio

r no

tice.

· Pr

inte

d in

Ger

man

y on

non

-chl

orin

e bl

each

ed p

aper

. 05

/16