Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University...

93
Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center

Transcript of Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University...

Page 1: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Preprocessing

John VanMeter, Ph.D.

Center for Functional and Molecular ImagingGeorgetown University Medical Center

Page 2: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Fixation Thumb movement

time

Recall Analysis of fMRI Data is Based on Examining Changes in Voxel

Across Time

Page 3: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Basic Preprocessing Chain

Page 4: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Slice Timing Correction

• fMRI data typically acquired using 2D acquisitions (i.e. one slice at a time)

• Order of slices can be acquired in different ways– Ascending or descending (slice order is sequential)– Interleave: even numbered slices acquired then odd

numbered slices or vice versa

• Order of slice acquisition determines when in the hemodynamic response the signal for a slice is acquired

Page 5: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.
Page 6: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Slice Timing Correction

• Uses temporal interpolation to make it appear as though all of the slices were acquired at the same time

• Thus, HRF across slices are aligned• Interpolation will be most effective if the

sampling rate (time between slices) is higher than the changes in the data

• Generally more effective for short TR (1-2 secs) than larger TR (>3 secs)

Page 7: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Order of Slice Timing Correction and Motion Correction

• Slice timing first if data acquired interleaved– Small changes in head position between slices

will cause timing differences to be off by 1/2 a TR

• Motion correct first if ascending or descending or short TR

• Slice timing correction generally unnecessary for block designs regardless of slice acquisition order and TR

Page 8: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Effect of Head Motion

Page 9: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Example of Ringing

Page 10: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Minimizing Head Motion

• Use of various types of restraints (padding, bite bar, vacuum cushion, face mask)

• Mock scanner training– Accustomization to

environment– Reinforcement systems

• Impress importance of not moving on subjects

Page 11: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Motion Correction (aka Realignment)

• Coregister each volume in the run to a reference volume

• Possible reference volumes– First volume in the run– Middle volume in the run– Average of all the volumes in the run before

motion correction

• No consensus on which choice of reference volume is best but typically first volume is used

Page 12: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Target

Reslice

Page 13: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Surface Registration

Page 14: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Coregistration Algorithm Components

• Four components are needed for any coregistration algorithm– Model that defines the set of transformations (eg.

translations, rotations, scaling, etc) used– Search algorithm to test different combinations of

the model parameters to find the “best” set– Cost Function that provides estimate of how well

registered the two volumes are– Interpolation algorithm to reslice/reformat and create

a new volume based on the best model parameters

Page 15: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Transformation

• Described by number of ways that one volume can be changed to match another (degrees of freedom)

• Rigid-body transform allows for translation in all 3 directions and rotation about all 3 axes (6 degrees of freedom)

• Higher transforms could be used but for motion correction rigid-body transform is most common and appropriate

Page 16: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Search Algorithm

• Systematic method for searching for the best combination of transformation parameters that aligns the reslice volume to the target volume

• Cost function – provides measure of how closely aligned two images are

Page 17: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Standard Deviation of the Ratio

= ?

Standard Deviationof ratio of all brain voxels

= 0

ResliceTarget Ratio Image

Page 18: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Standard Deviation of the Ratio

=

ResliceTarget Ratio Image

Standard Deviationof ratio of all brain voxels

>> 0 or

Page 19: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

ResliceTarget

y

x

z10o

Page 20: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Image Interpolation

Reslice

Page 21: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.
Page 22: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.
Page 23: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Interpolation Methods

• Nearest Neighbor– voxel intensity in new volume equal to the closest

voxel in the original volume

• Trilinear– voxel intensity in new volume is based on weighted

average of surrounding voxels from the original volume

– weights based on distance from the new voxel

Page 24: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Reslice (Rz = -10o)Target

Nearest Neighbor Trilinear

Page 25: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Original

90o 180o 360o

10o 20o

Page 26: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Sinc Windowed Sinc

Page 27: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Original 10o 20o

90o 180o 360o

Page 28: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Quality Assurance: Motion Correction Plots

• Examine the amount of motion in each run by looking at plots of motion

• Big spikes in motion plots problematic

• Run motion correction twice to see how much residual motion there was from first application of motion correction

Page 29: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Pre-motion correction

Post-motion correction

Page 30: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

How Much Motion is Acceptable?

• Examine residual motion correction plot for the maximal amount of motion in each dimension

• Ideal– Less than 0.5-0.75 mm– Less than 0.5o

• Patient population dependent– Children, rare diseases,

hard to recruit subject, etc

– Go with what you got

Page 31: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Distortion Correction

• Geometric distortion occurs in EPI sequences arising from inhomogeneity in static magnetic field

• Shimming adjusts for distortions due to head and body being in the field

• Automatic shimming generally available though not always sufficient to prevent distortion

• On our scanner geometric distortion is very minimal

Page 32: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Susceptibility Artifacts

Ojemann, NeuroImage 1997

Page 33: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Examples of Geometric Distortion

sin

use

s

ea

rca

na

ls

Poor Shimming Our Scanner WithAutomatic Shimming

Page 34: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Geometric Distortion in Our Scanner

Distortions

Page 35: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Field Mapping

• Collect two short scans at two different TE’s to determine differences in the phase component of the signal (difference is the field map)

• Used to correct distortion

Page 36: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Coregistration: Registering Functional Data to Structural Scan

• Registering functional and structural data useful for both looking at single subject results (e.g. overlaying statistical results onto that subjects structural scan)

• Also used as precursor to warping subject into standard or atlas space for multi-subject analyses

Page 37: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Spatial Normalization

• Variations between individual brains is large:– Overall size varies from 1100 cc to 1500 cc (30%

variation)– Major landmarks such as central sulcus will vary

considerable in position, branching, and length

• Spatial normalization warps individual brains into a common reference space

• Allows for examination of fMRI signal changes across individuals within a group or between groups of subjects

• Most commonly used reference space is based on the Talairach atlas

Page 38: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Talairach Atlas

• Atlas of brain anatomy• Developed by two French neurosurgeons Jean

Talairach and Pierre Tournoux• Defines a coordinate system used for

stereotaxic reference• Stereotaxic space is a “precise” mapping of a

brain into 3D coordinate system• The Talairach atlas has become the de facto

standard in Neuroimaging

Page 39: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Talairach Atlas

• Originally used to for surgical planning for deep subcortical structures in the brain (e.g. basal ganglion, thalamus, etc.)

• Based on the brain of 69 YO French female

• Numerous stories about the preparation of this woman’s brain for sectioning

Page 40: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Coronal Atlas Sections

Page 41: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Sagittal Atlas Sections

Page 42: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Disadvantages of Talairach

• Based on a single cadaver brain and not representative of younger living brains

• Left-Right hemispheric differences are ignored (assumed symmetric for spatial normalization)

• Cerebellum completely ignored• Notorious problems (e.g. occipital lobe is much

smaller in atlas than most brains) • Non-European brains (e.g. Asian) do not fit well

within the Talairach space

Page 43: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Talairach Coordinate System

• Origin located at the Anterior Commissure (AC)

• Three axes define coordinate system:– Axial plane parallel to the line passing

through the AC – PC– Sagittal plane parallel to the AC – PC line– Coronal plane perpendicular to other two

Page 44: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Talairach Coordinate System

• X-axis goes from the Left Hemisphere to the Right Hemisphere. Positive X coordinate is Right Hemisphere. Range: -75 to +75mm

• Y-axis goes from the Anterior extent to the Posterior extent. Positive Y coordinate is anterior of the AC. Range: -105 to +70mm

• Z-axis goes from the Superior extent to the Inferior extent. Positive Z coordinate is above the plane passing through the AC-PC. Range: -40 to +65mm

Page 45: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Automated Talairach Registration

• Transform individual brains into a standard space – typically Talairach Space

• Colloquially referred to as Talairach’ing

• Formally referred to as Spatial Normalization

• Same components as motion correction – mathematical model, search algorithm, cost function, image interpolation

Page 46: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Spatial Normalization

• Register image of an individual brains to match a template image in a standard space, typically the Talairach atlas

• Linear models incorporate parameters for scale and skew (12 degrees of freedom)

• Nonlinear models use either polynomials or cosine functions to model warping

• Higher orders provide greater accuracy of fit

Page 47: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Templates

• As with the French woman’s brain, there are numerous stories about the various templates in use

• Several of the templates have been developed in an ad hoc and poorly documented fashion

Page 48: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

T1-MRI Template (MNI 305)

Page 49: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

EPI Template

(FIL)

Page 50: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Methods of Template Creation

• Manually transform each individual brain into Talairach space using linear stretching then average - MNI 305 done this way with 305 young volunteer’s T1 MRI scans after

• Spatially normalize each subject to match an existing template then average

• Round-Robin registration of each subject to every other subject over multiple iterations, averaged then transformed into atlas space

Page 51: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Comparison of Template Creation Methods

Round Robin Register to Existing

Page 52: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

6-8 yrs 14-16 yrs 32 yrs

Pediatric Templates

Page 53: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Nonconformity of Templates with Talairach Atlas:

MNI vs Talairach

• MNI 305 does not exactly match the atlas– MNI 305 is bigger in all three dimensions– Near center of the brain MNI 305 matches

the atlas best– Towards the extents larger differences– Variations are not uniform, overall MNI 305

is ~5mm taller in the superior-inferior dimension however parts of the temporal lobes extend ~10mm lower

Page 54: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Accuracy of Talairach Registration Methods

• Classical Talairach method – Good alignment of subcortical structures– Cerebral structures substantially less well aligned– Subjective since landmarks especially PC and to

lesser extent AC are difficult to identify

• Automated Spatial Normalization– Cerebral structures are aligned better– Overall alignment is better– But MNI and ICBM templates don’t conform to

Talairach -> MNI vs Talairach space

Page 55: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Classical Talairach Method vs Nonlinear Spatial Normalization

Classical Talairach Automated Nonlinear

Page 56: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Classical Talairach Method vs Nonlinear Spatial Normalization

Classical Talairach

T1 Template

NonlinearTransformatio

n

Page 57: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Converting MNI to Talairach: Piecewise Linear

• Above the AC (Z >= 0):– X'= 0.9900X– Y'= 0.9688Y +0.0460Z– Z'= -0.0485Y +0.9189Z

• Below the AC (Z < 0):– X'= 0.9900X– Y'= 0.9688Y +0.0420Z– Z'= -0.0485Y +0.8390Z

Page 58: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.
Page 59: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Converting MNI to Talairach: Nonlinear

• http://www.bioimagesuite.org/Mni2Tal/index.html

QuickTime™ and aTIFF (LZW) decompressor

are needed to see this picture.

Atlas

Piecewise-Linear correction

Non-linear Correction

Page 60: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Comparison of Different Linear Models

Page 61: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

SPM5 Spatial Normalization Method

• Co-register mean EPI image to subject’s MPRAGE (or other high resolution structural)

• Segment MPRAGE by tissue type (i.e. CSF, gray, and white matter)

• Spatially normalize subject’s gray matter map to template gray matter map

• Apply both transforms to each EPI volume in the run

Page 62: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

SPM5 Spatial Normalization - Good Idea But…

• Structures of interest in fMRI are in gray matter

• Matching gray matter to gray matter bound to be an improvement

• But it relies on accuracy of co-register step

Page 63: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Coregistering EPI to MPRAGE Can be problematic

Ratio Image

• EPI acquired with a FatSat pulse - thus scalp eliminated (good for fMRI; reduces ghosting)

• MPRAGE has bright fat signal from scalp

• Coregistration can get thrown off and try to fit edges of EPI to bright scalp instead of bran

Page 64: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Smoothing

• Form of a more general image processing technique called convolution

• Neighborhood operation

• New pixel value based on weighted sum of a pixel and its neighbors

• A convolution operator is referred to as a kernel

Page 65: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Average Kernel

1 1 1

1 11

11 1

Page 66: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

1 1 1

1 11

11 1

32

32 32

3232 32

32

32

32* = ?32

Page 67: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

32

32 32

3232 32

32

32

1* = ?

1 1 1

1 11

11 1

28

Page 68: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

A kernel is defined by its weights and size

1 1 1

1 11

11 1

1 1 1

1 11

11 11 1 1

1 11

11 1

1 1 1

1 11

11 11 1 1

1 11

11 1

3x3

5x5

Page 69: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Gaussian Kernel

• Weights in Gaussian kernel defined by normal distribution

• Gaussian kernel specified by Full-Width at Half Maximum (FWHM)

Page 70: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

2D Gaussian Kernel

Page 71: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

2D Gaussian Kernel

1.07 1.14 1.07

1.16 1.141.14

1.141.07 1.07

FWHM ~ 12mm2

Page 72: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Example Reduced Noise Using Smoothing

Page 73: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

OriginalPET Image

12mm3

6mm3

24mm3

Page 74: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Gaussian Smoothing

• Advantage

– Removes isolated points of noise in an image

– Compensates for imperfect spatial normalization

– Helps to prepare data to meet statistical analysis requirements

– Reduces false positives in statistical analysis

• Disadvantage

– Reduces the spatial resolution of the image; looks blurrier

– Peaks are squashed

• Ideal filter size is one that matches the size of the areas of activation

(Matched Filter Theorem) - generally unknown and varies across brain

• General rule of thumb for fMRI data is to use a filter width that is twice the

voxel size

Page 75: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Smoothing & Statistical False Positives

Random dataset left is unsmoothed and right is

smoothed

Page 76: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Smoothing and SNR

• Smoothing actually increases the ability to detect task-related signal changes (i.e. functional SNR increases)

• Cost is of course reduced spatial resolution

• Relies on spatial correlation of fMRI data (i.e. neighboring voxels have similar intensity and activation characteristics)

Page 77: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Temporal Filtering

• Similar to spatial filtering expect the data are processed across time

• Some sources of temporal noise– Transient jumps and drops in the global

signal from timepoint to timepoint (ie. overall brightness fluxuates)

– Drift in MRI signal over time– Head movement

Page 78: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Global Normalization

• Global signal is defined as the average intensity of all the voxels in the brain

• Variations in the global signal can swamp the regional changes in the MRI signal that we are trying to measure

• Ratio correction divides the intensity at each voxel by the global signal in that scan and multiples by a constant

• ANCOVA is an alternative that allows for differences in variations based on trial type or condition

Page 79: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Ratio Normalization

-6

-4

-2

0

2

4

6

8

10

1 6 11 16 21 26 31 36 41 46

pre globalnormalizationpost globalnormalization

Page 80: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Signal Drift Across Time

• Gradually, over time the MRI signal in a voxel drifts

• This drift can vary from one voxel to the next

• A simple model of this drift is as a linear rise or fall in the signal

Page 81: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Linear Detrending

Page 82: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

High-Pass Filtering

• Similar to linear detrending but higher order variations are also removed

• Types of signal variations that can be corrected are more complex

• All of the signal below a certain frequency is removed.

Page 83: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Non-linear Drift

-20

-15

-10

-5

0

5

10

1 22 43 64 85 106

Page 84: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Effect of Slow Non-linear Drifts

410

420

430

440

450

460

470

480

490

1 22 43 64 85 106

Page 85: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

High-Pass Filtering

• Nyquist Sampling Theorem – removing signal fluxuations that are greater than half the frequency of the task potentially removes signal of interest

– Thus, cut-off frequency should be half the task frequency

• For block designs the cut frequency can be determined from the periodicity of your paradigm

• The cut-off is specified in time in SPM

– Thus, combined time of the on- and off-blocks times 2 is the cut-off for a block design

• For event related designs there is no simple formula; using a cut-off that is a ~2 minutes long is a safe bet

Page 86: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

High-Pass Filtering

Page 87: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Band-Pass Filter

• Remove signal changes that are both higher and lower than task frequency in a block design

• Cut-offs would be set to 2x and 1/2x the task frequency

• Advantage is removal of both signal drift (high-pass) and cardiac, respiration signal changes (low-pass)

Page 88: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Low-Pass Filtering

Typical Task Frequency

Page 89: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Quality Control in fMRI

• Very important to examine your data after each stage of preprocessing and statistics– Look at raw data for artifacts – Examine realignment plots– Examine mean & variance images before and after realignment

(ana4dto3d toolbox for SPM)– Look at movies of time series before and after realignment

(MEDx or AQuA toolbox for SPM)– Examine plots of image-to-image signal variance (tsdiffana

toolbox for SPM)– Examine how well spatial normalization worked (use Check Reg

in SPM)– Look at single subject statistics for ringing (best with task vs.

lowest control condition)– Do statistics make sense (eg. if motor response used is the

appropriate motor cortex activated?)

Page 90: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

fMRI Raw Data Artifacts

• Spikes - caused by transient electrical discharges during scanning; something is leaking RF noise into the scanner room

• Ghosting - Nyquist reconstruction artifacts can sometimes be limited by choice of certain acquisition parameters (eg. echo spacing)

Page 91: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

Ghosting on Our Scanner

• On our scanner adjusting echo spacing to be outside of 0.7-0.8ms minimizes ghosting

Ghosting Artifact

Page 92: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

BIG Technique Experimental Design

• Behavior Interleaved Gradient (BIG) technique (aka Sparse Sampling) puts a fixed delay between each EPI acquisition

• During this break auditory stimuli can be presented without noise from gradients

• Subjects can verbally respond with minimal effect on motion in the EPI image

• Relies on delay in hemodynamic response• Also called Sparse Sampling

Page 93: Preprocessing John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.

BIG Acquisition

• Requires accurate timing of the task relative to the the scan acquisition to capture peak BOLD response in the volume

• Greatly increases scan time