Precast Concrete Barriers - · PDF fileVersatile Precast Concrete Traffic Barrier Walls Tricon...

download Precast Concrete Barriers - · PDF fileVersatile Precast Concrete Traffic Barrier Walls Tricon Precast has produced and delivered standard TxDOT designs, common commercial designs

If you can't read please download the document

Transcript of Precast Concrete Barriers - · PDF fileVersatile Precast Concrete Traffic Barrier Walls Tricon...

  • Precast Concrete Barriers - Texas

  • Versatile Precast Concrete Traffic Barrier Walls Tricon Precast has produced and delivered standard TxDOT designs, common commercial designs and custom barriers of all kinds since its inception. Today, we continue to be one of Texas's leading producers of precast traffic control barrier wall products. With headquarters in Houston, Tricon operates two state of the art plants in Texas; Houston in the Gulf Coast region and San Antonio in the Central Texas region.

    Widely used in traffic separation applications on Texas roadways, Tricon's barrier wall products are now recognized as concrete security solutions for many companies. They serve as solutions for parking and security for petrochemical plants, refineries, shipping ports and airports. Additionally, our innovative designs have proven themselves in temporary and permanent retaining wall structures as well as in flexible bulk material storage options.

    Our standard Barrier Wall designs include:

    PCTB (Jersey Style) F-Shape 36 Single Slope 42 Single Slope Low Profile Type 1 Low Profile Type 2

    Our custom designs include:

    High Speed Race Barrier Radiation Portal Blocks Single Slope Modified ("Wildlife Crossing") PCTB (Jersey Style) to your customization

    Barriers can be produced with or without connection hardware of which a variety of types are available. Special lengths and heights to meet project needs can be accommodated. Traffic barriers can also be produced using commercial mix designs. Rental and buyback options are available.

    For more information concerning Tricon Concrete Traffic Barrier Walls, please contact a sales professional at (281) 931-9832.

  • 14"

    DETAIL OF BARRIER SHAPEELEVATION OF BARRIER

    8"

    32"

    10"

    19"

    7"

    PVC

    2"DIA

    27"

    1" 1"

    1"R

    10"R

    1"R

    3"

    32"

    36"

    36"48"36"

    36"

    10-0"

    PVC

    2"DIA

    PVC

    2"DIA

    TYPE 2 PCTB (2) - 04

    www.triconprecast.com(281) 931-0061(281) 931-9832

    HOUSTON, TEXAS, 7706015055 HENRY ROAD

    Precast LimitedTM

    ENGINEERINGSTRUCTURALCIVIL

    PH. (616) 261-8630

    WYOMING, MI 49509

    1505 44th STREET, SUITE B

    (281) 931-9832HOUSTON, TEXAS, 77060

    15055 HENRY ROAD

    ALL BARRIER INQUIRES

    1-877-387-9266

    MAIN OFFICE/PLANT

    15055 HENRY RD. HOUSTON, TX

    CENTRAL TEXAS PLANT

    21248 OLD NACOGDOCHES RD. NEW BRAUNFELS, TX

    BARRIER DESIGNATION

    ELEMENTS PER TRUCKLOAD: 10

    WEIGHT PER ELEMENT: 4,500 lbs

    (TRICON SERVTEX COMMERCIAL BARRIER)

  • DETAIL OF BARRIER SHAPEELEVATION OF BARRIER

    8"

    32"

    10"

    19"

    7"

    PVC

    2"DIA

    27"

    14"

    PVC

    2"DIA

    1" 1"

    1"R

    10"R

    1"R

    3"

    32"

    36"48"36"

    60"

    10-0"

    TYPE 2 PCTB (2) - 04

    www.triconprecast.com(281) 931-0061(281) 931-9832

    HOUSTON, TEXAS, 7706015055 HENRY ROAD

    Precast LimitedTM

    ENGINEERINGSTRUCTURALCIVIL

    PH. (616) 261-8630

    WYOMING, MI 49509

    1505 44th STREET, SUITE B

    (281) 931-9832HOUSTON, TEXAS, 77060

    15055 HENRY ROAD

    ALL BARRIER INQUIRES

    1-877-387-9266

    MAIN OFFICE/PLANT

    15055 HENRY RD. HOUSTON, TX

    CENTRAL TEXAS PLANT

    21248 OLD NACOGDOCHES RD. NEW BRAUNFELS, TX

    BARRIER DESIGNATION

    ELEMENTS PER TRUCKLOAD: 10

    WEIGHT PER ELEMENT: 4,500 lbs

    (TRICON HOUSTON COMMERCIAL BARRIER)

  • DETAIL OF BARRIER SHAPE ELEVATION OF BARRIER

    3"

    3"

    1-1

    0"

    7"

    2"

    9"4"

    TOOLED RADIUS

    " CHAMFER OR

    10"

    R

    6"

    32"

    24"

    18"18" 36"

    LIFTING SLOT

    24"

    LIFTING INSERT

    24"

    10-0"

    1"

    " PLATE

    CONNECTOR

    11"

    ANGLE

    2"x2"x"

    REBAR

    10"

    CONNECTION TYPE J-HOOK(TOP VIEW SHOWN)

    24"

    (10 F - SHAPE)

    TYPE 4 CSB (8) - 10

    www.triconprecast.com(281) 931-0061(281) 931-9832

    HOUSTON, TEXAS, 7706015055 HENRY ROAD

    Precast LimitedTM

    ENGINEERINGSTRUCTURALCIVIL

    PH. (616) 261-8630

    WYOMING, MI 49509

    1505 44th STREET, SUITE B

    (281) 931-9832HOUSTON, TEXAS, 77060

    15055 HENRY ROAD

    ALL BARRIER INQUIRES

    1-877-387-9266

    MAIN OFFICE/PLANT

    15055 HENRY RD. HOUSTON, TX

    CENTRAL TEXAS PLANT

    21248 OLD NACOGDOCHES RD. NEW BRAUNFELS, TX

    BARRIER DESIGNATIONWEIGHT PER ELEMENT: 5,070 lbs

    ELEMENTS PER TRUCKLOAD: 10

    CONDUIT TROUGH

  • 1"

    " PLATE

    CONNECTOR

    11"

    ANGLE

    2"x2"x"

    REBAR

    10"

    CONNECTION TYPE J-HOOK(TOP VIEW SHOWN)

    24"

    3"

    6"

    DETAIL OF BARRIER SHAPE

    3"

    1-1

    0"

    7"

    2"

    9"4"

    TOOLED RADIUS

    " CHAMFER OR

    10"R

    ELEVATION OF BARRIER

    30-0" TOTAL BARRIER LENGTH

    30- 0" BARRIER SEGMENT.

    6- 0" FROM EACH END OF THE

    36" LONG X 3"DEEP, BEGINNING

    (REQUIRED) TWO DRAINAGE SLOTS

    72" 36"

    32"

    24"

    SYMMETRICAL ABOUT >

    (30 F - SHAPE)

    TYPE 1 CSB (1) - 10

    www.triconprecast.com(281) 931-0061(281) 931-9832

    HOUSTON, TEXAS, 7706015055 HENRY ROAD

    Precast LimitedTM

    ENGINEERINGSTRUCTURALCIVIL

    PH. (616) 261-8630

    WYOMING, MI 49509

    1505 44th STREET, SUITE B

    (281) 931-9832HOUSTON, TEXAS, 77060

    15055 HENRY ROAD

    ALL BARRIER INQUIRES

    1-877-387-9266

    MAIN OFFICE/PLANT

    15055 HENRY RD. HOUSTON, TX

    CENTRAL TEXAS PLANT

    21248 OLD NACOGDOCHES RD. NEW BRAUNFELS, TX

    BARRIER DESIGNATIONWEIGHT PER ELEMENT: 14,330 lbs

    ELEMENTS PER TRUCKLOAD: 3

    CONDUIT TROUGH

  • 1"

    " PLATE

    CONNECTOR

    11"

    ANGLE

    2"x2"x"

    REBAR

    10"

    CONNECTION TYPE J-HOOK(TOP VIEW SHOWN)

    24"

    3"

    ELEVATION OF BARRIER

    30-0" TOTAL BARRIER LENGTH

    SYMMETRICAL ABOUT >

    10"6" 6"

    DETAIL OF BARRIER SHAPE

    " CHAMFER

    36"

    24" 24"72"48"36"

    PSSCB - JJ

    BARRIER DESIGNATIONWEIGHT PER ELEMENT: 18,500 lbs

    www.triconprecast.com(281) 931-0061(281) 931-9832

    HOUSTON, TEXAS, 7706015055 HENRY ROAD

    Precast LimitedTM

    ENGINEERINGSTRUCTURALCIVIL

    PH. (616) 261-8630

    WYOMING, MI 49509

    1505 44th STREET, SUITE B

    (281) 931-9832HOUSTON, TEXAS, 77060

    15055 HENRY ROAD

    ALL BARRIER INQUIRES

    1-877-387-9266

    MAIN OFFICE/PLANT

    15055 HENRY RD. HOUSTON, TX

    CENTRAL TEXAS PLANT

    21248 OLD NACOGDOCHES RD. NEW BRAUNFELS, TX

    (36" SINGLE SLOPE CONCRETE BARRIER)

    ELEMENTS PER TRUCKLOAD: 2

  • 3"

    ELEVATION OF BARRIER

    30-0" TOTAL BARRIER LENGTH8"8" 8"

    TOOLED RADIUS

    " CHAMFER OR

    2-0"(OPTIONAL)

    CONDUIT TROUGH6"

    3"

    DETAIL OF BARRIER SHAPE

    SYMMETRICAL ABOUT >

    36"72"

    42"

    END OF THE 30- 0" BARRIER SEGMENT.

    3LG X 3"DP BEGINNING 6- 0" FROM EACH

    (REQUIRED) TWO DRAINAGE SLOTS

    1"

    " PLATE

    CONNECTOR

    11"

    ANGLE

    2"x2"x"

    REBAR

    10"

    CONNECTION TYPE J-HOOK(TOP VIEW SHOWN)

    24"

    TYPE 1 SSCB (2) - 10

    BARRIER DESIGNATIONWEIGHT PER ELEMENT: 23,149 lbs

    www.triconprecast.com(281) 931-0061(281) 931-9832

    HOUSTON, TEXAS, 7706015055 HENRY ROAD

    Precast LimitedTM

    ENGINEERINGSTRUCTURALCIVIL

    PH. (616) 261-8630

    WYOMING, MI 49509

    1505 44th STREET, SUITE B

    (281) 931-9832HOUSTON, TEXAS, 77060

    15055 HENRY ROAD

    ALL BARRIER INQUIRES

    1-877-387-9266

    MAIN OFFICE/PLANT

    15055 HENRY RD. HOUSTON, TX

    CENTRAL TEXAS PLANT

    21248 OLD NACOGDOCHES RD. NEW BRAUNFELS, TX

    (42" SINGLE SLOPE CONCRETE BARRIER)

    ELEMENTS PER TRUCKLOAD: 2

  • 3"

    ELEVATION OF BARRIER

    30-0" TOTAL BARRIER LENGTH3"10" 10"

    TOOLED RADIUS

    " CHAMFER OR

    2-0"(OPTIONAL)

    CONDUIT TROUGH6"

    3"

    DETAIL OF BARRIER SHAPE

    SYMMETRICAL ABOUT >

    36"72"

    42"

    END OF THE 30- 0" BARRIER SEGMENT.

    3LG X 3"DP BEGINNING 6- 0" FROM EACH

    (REQUIRED) TWO DRAINAGE SLOTS

    (#4) V2 BAR

    REBAR GRID

    24"

    CONNECTION TYPE R

    10"

    3"

    REBAR GRID

    SLOT FOR

    (TYPICAL AT BOTH ENDS OF SEGMENT)

    (TOP VIEW SHOWN)

    33

    "

    3

    "

    (#4) V2 BARS

    3 (#8) BARS~

    18"

    5

    "17

    "

    WELDED REBAR GRID

    2 (#6) BARS~

    PER BARRIER SEGMENT

    6 TWO PIECE BARS~

    TYPE 1 SSCB (2) - 10

    BARRIER DESIGNATIONWEIGHT PER ELEMENT: 23,149 lbs

    www.triconprecast.com(281) 931-0061(281) 931-9832

    HOUSTON, TEXAS, 7706015055 HENRY ROAD

    Precast LimitedTM

    ENGINEERINGSTRUCTURALCIVIL

    PH. (616) 261-8630

    WYOMING, MI 49509

    1505 44th STREET, SUITE B

    (281) 931-9832HOUSTON, TEXAS, 77060

    15055 HENRY ROAD

    ALL BARRIER INQUIRES

    1-877-387-9266

    MAIN OFFICE/PLANT

    15055 HENRY RD. HOUSTON, TX

    CENTRAL TEXAS PLANT

    21248 OLD NACOGDOCHES RD. NEW BRAUNFELS, TX

    (42" SINGLE SLOPE CONCRETE BARRIER)

    ELEMENTS PER TRUCKLOAD: 2

  • 28"

    26"

    MIN. 4" THREADS

    1" DIA. x 26" RODS

    (4) 1" HEX NUT GRADE 5

    (4) 1" FLAT HARDENED WASHER

    (2) PLATE WASHER 5" x 10" x "

    4" 4"

    (2) CONNECTION BOLTSASTM A36

    10"

    5"

    7

    "3

    "3

    "

    PLATE WASHER5" x 10" x "

    2-2"

    2"

    DETAIL OF BARRIER SHAPE ELEVATION OF BARRIER

    20-0" TOTAL BARRIER LENGTH

    FOR JOINT CONNECTIONS

    STEEL PIPE REQUIRED

    20"

    30"24"24"30"