Pre-Demolition Hazardous Materials Survey Report

192
General Information 1.1 AHERA Certificates Inspection Summary 1.2 Sample Inventories Laboratory Data Not Numbered Not Numbered 2.1 Pre-Demolition Hazardous Materials Survey Report CTUIR-FEMA Mitigation Grant Management Prepared for: Wenaha Group on behalf of: Confederated Tribes of the Umatilla Indian Reservation 5 N. Colville Street, #200, Walla Walla, WA 99362 509.956.3026 Main 866.727.0140 Fax 888.248.1939 Toll-Free April 2021 Project No.: 67796.000 PBSUSA.COM

Transcript of Pre-Demolition Hazardous Materials Survey Report

General Information 1.1

AHERA Certificates

Inspection Summary 1.2Sample InventoriesLaboratory Data

Not NumberedNot Numbered2.1

Pre-Demolition Hazardous Materials Survey Report

CTUIR-FEMA Mitigation Grant Management

Prepared for:

Wenaha Groupon behalf of:

Confederated Tribes of the Umatilla Indian Reservation

5 N. Colville Street, #200, Walla Walla, WA 99362509.956.3026 Main

866.727.0140 Fax888.248.1939 Toll-Free

April 2021Project No.: 67796.000

PBSUSA.COM

Pendleton, OR CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indian ReservationAsbestos Survey Report

Pendleton, OR

BUILDING DATACTUIR-FEMA Mitigation Grant Management

BACKGROUND INFORMATION

GENERAL INFORMATIONCLIENT DATAConfederated Tribes of the Umatilla Indian Reservation

Pendleton, OR 97801(541) 276-8221

• The type, location and approximate quantity of suspect asbestos-containing materials• Bulk sampling of selected suspect building materials• Laboratory analytical data of bulk materials sampled

SURVEY SCOPE

With regard to asbestos, PBS endeavored to locate all the suspect asbestos-containing materials in the building; however, suspect asbestos-containing materials may be present and concealed within wall, ceiling or floor spaces. If suspect materials that are not identified in this report are uncovered during demolition or renovation activities, testing should be performed prior to impact. PBS has conducted a physical inspection of the building, compiled this report consistent with the survey scope, and certifies that the information is correct and accurate within the standards of professional quality and contractual obligations.

PBS Engineering and Environmental Inc. (PBS) has performed a general asbestos survey of accessible building areas for the purpose of Compliance in accordance with OSHA in 29 CFR 1910.1001 and compiled a report with the following information:

1.1April 2021

Project No.: 67796.000 Phase No.: 0001

Caitlin GundertMark Hiley

IN-20-8844B1019081

DateSignature

Project Manager Prime Inspector

DateSignature

Accreditation #: Accreditation #:

© 2021 PBS Engineering and Environmental Inc.

4/30/2021

INSPECTION SUMMARY

Pendleton, OR CTUIR-FEMA Mitigation Grant ManagementAsbestos Survey Report

Caitlin GundertDATES SURVEYED BY ACTIVITY

Inspection, Survey, and Sample

ASBESTOS MATERIALSThe following materials either tested positive, or, based on the experience of PBS field personnel, were not tested and should be considered asbestos-containing. Materials that had mixed results are considered positive. Materials not sampled may contain asbestos and should be tested to verify asbestos content prior to impact through demolition, renovation, etc. (+) Tested Positive, (M) Mixed Results, (P) Presumed Positive, (T) Previously Tested Positive.

DetailsResults Material Description Location

PBS has investigated accessible areas inside of the building(s) to locate suspect asbestos-containing materials (ACM). Suspect materials may be present in concealed areas (e.g., behind walls and under carpet). The findings are listed below.

4/12/2021 - 4/16/2021

See sample inventory for specific results.

60 LF73479 Sampson, Original Exterior Windows

Caulk, White(+)

GoodNon-friable

3%

340 SF73479 Sampson, Kitchen & NW Bedroom

Vinyl Floor Tile, Red(+)

GoodNon-friable

5%

1,600 SF73479 Sampson, Interior WallsTroweled Textured Material(+)

GoodFriable

5%

1,600 SF73479 Sampson, Interior WallsGypsum Wallboard/Joint Compound

(+)

GoodFriable

2%

1.2April 2021

Project No.: 67796.000 Phase No.: 0001

Confederated Tribes of the Umatilla Indian Reservation

INSPECTION SUMMARY

Pendleton, OR CTUIR-FEMA Mitigation Grant ManagementAsbestos Survey Report

140 SF73479 Sampson, NW BedroomVinyl Floor Tile, White/Tan(+)

GoodNon-friable

3%

50 SF73479 Sampson, NW BathroomVinyl Floor Tile, Gray(+)

GoodNon-friable

3%

50 SF73499 Sampson, SE BathroomSheet Floor Covering, Orange(+)

GoodNon-friable

15%

50 SF73499 Sampson, SE BathroomMastic, Brown(+)

GoodNon-friable

2%

2,400 SF73499 Sampson, Interior WallsGypsum Wallboard/Joint Compound

(+)

GoodFriable

3%

340 SF73499 Sampson, KitchenSheet Floor Covering, Gray(+)

GoodNon-friable

30%

340 SF73499 Sampson, KitchenMastic, Brown(+)

GoodNon-friable

3%

1 EA73499 Sampson, KitchenSink Undercoating, Gray(+)

GoodNon-friable

10%

1.3April 2021

Project No.: 67796.000 Phase No.: 0001

Confederated Tribes of the Umatilla Indian Reservation

INSPECTION SUMMARY

Pendleton, OR CTUIR-FEMA Mitigation Grant ManagementAsbestos Survey Report

120 SF49591 River, E. Kitchen HallwayTroweled Textured Material(+)

GoodFriable

3%

2,800 SF49683 River, RoofCementitious Roof Shingles(+)

GoodNon-friable

5%

100 LF49683 River, Shop, S. ExteriorResidual Black Tar(+)

GoodNon-friable

3%

2,400 SF52153 Cayuse, Interior WallsGypsum Wallboard/Joint Compound

(+)

GoodFriable

3%

100 SF52277 Cayuse, Well RoomSheet Floor Covering, Brown(+)

GoodNon-friable

15%

100 SF52277 Cayuse, Well RoomMastic, Brown(+)

GoodNon-friable

3%

2,000 SF52277 Cayuse, Log WallsTar/Sealant, Black(+)

GoodNon-friable

15%

200 SF52277 Cayuse, TrailerSheet Floor Covering, Brown/Pebbled

(+)

GoodNon-friable

18%

1.4April 2021

Project No.: 67796.000 Phase No.: 0001

Confederated Tribes of the Umatilla Indian Reservation

INSPECTION SUMMARY

Pendleton, OR CTUIR-FEMA Mitigation Grant ManagementAsbestos Survey Report

200 SF52277 Cayuse, TrailerMastic, Yellow(+)

GoodNon-friable

2%

200 SF52277 Cayuse, TrailerSpray-on Ceiling, Black(+)

GoodFriable

5%

1,600 SF53017 Cayuse, Interior WallsTroweled Textured Material(+)

GoodFriable

3%

2,400 SF53017 Cayuse, CeilingSpray-on Ceiling, White(+)

GoodFriable

7%

50 SF53017 Cayuse, SE BathroomSheet Floor Covering, Beige(+)

GoodNon-friable

15%

50 SF53017 Cayuse, SE BathroomMastic, Yellow(+)

GoodNon-friable

3%

1.5April 2021

Project No.: 67796.000 Phase No.: 0001

Confederated Tribes of the Umatilla Indian Reservation

INSPECTION SUMMARY

Pendleton, OR CTUIR-FEMA Mitigation Grant ManagementAsbestos Survey Report

MATERIALS THAT TESTED NEGATIVE FOR ASBESTOS

Material (type) Location

The following materials tested negative based on ASHARA sampling minimums and testing by NVLAP participating laboratories. Although no asbestos was detected, it is possible that further sampling could indicate asbestos content. It may be prudent to test prior to impact through demolition, renovation, etc.

Cementitious Roof ShinglesInsulation, TanSpray-on Ceiling Texture, WhiteMortarSheet Floor Covering, White/GrayDuct Vent Tape, SilverSnap-On Flooring, Brown/TanSnap-On Flooring, Lt. GrayBathtub MasticCaulk, BathtubCarpeted FlooringInsulation, Pink/YellowVapor Barrier, BlackCarpeted FlooringSheet Floor Covering, Blue/BlackMortarVinyl Floor Tile, Gray/BlackLaminate Counter/MasticFiberboard/MasticVinyl Floor Tile, Green/BlackMastic, BathtubDuct Vent Tape, SilverCaulkInsulation, Pink/YellowVapor Barrier, BlackCeramic Tile/GroutInsulation, FiberglassCeramic Tile/Grout

73479 Sampson, Roof73479 Sampson, Exterior Walls

73479 Sampson, Ceiling73479 Sampson, Fireplace

73479 Sampson, Main Entry

73479 Sampson, Duct73479 Sampson, Flooring

73479 Sampson, Flooring

73479 Sampson, Bathrooms

73479 Sampson, Bathrooms

73479 Sampson, Living Room

73479 Sampson, Insulated Areas

73479 Sampson, Insulated Areas

73499 Sampson, North Bathroom

73499 Sampson, NW Bedroom

73499 Sampson, Stove73479 Sampson, North Hall 73499 Sampson, Kitchen

73499 Sampson, Stove73499 Sampson, NE Bedroom

73499 Sampson, Bathrooms

73499 Sampson, Duct73499 Sampson, Doors/Windows

73499 Sampson, Insulated Areas

73499 Sampson, Insulated Areas

73499 Sampson, Flooring

49587 River, Walls/Ceilings

49587 River, Bathrooms

1.6April 2021

Project No.: 67796.000 Phase No.: 0001

Confederated Tribes of the Umatilla Indian Reservation

INSPECTION SUMMARY

Pendleton, OR CTUIR-FEMA Mitigation Grant ManagementAsbestos Survey Report

Wall and Ceiling Plaster 49587 River, BathroomsVapor Barrier, Black 49587 River, Walls/CeilingsMortar 49587 River, FireplaceCaulk 49587 River, Windows/DoorsCementitious Roof Shingles 49587 River, RoofMillboard 49587 River, ExteriorGypsum Wallboard/Joint Compound 49587 River, Shop BuildingCeramic Tile/Grout 49591 River, Floors/WallsMortar 49591 River, FireplaceVinyl Floor Tile, Beige 49591 River, Southwest RoomGypsum Wallboard/Joint Compound 49591 River, Interior WallsMastic, Cream 49591 River, FlooringInsulation, Fiberglass 49591 River, Walls/CeilingMastic, Yellow/Tan 49591 River, N. Living RoomVapor Barrier, Black 49591 River, Sub FlooringCaulk 49591 River, Windows/DoorsCementitious Roof Shingles 49591 River, All RoofingFiberboard, Beige 49591 River, Mother-in-LawFiberboard, White/Brown 49683 River, Walls/CeilingCounter/Mastic 49683 River, BathroomsTroweled Textured Material 49683 River, WallsCaulk 49683 River, BathroomsCarpeted Flooring 49683 River, ThroughoutSheet Floor Covering, White 49683 River, Bathroom/LaundryVapor Barrier, Black 49683 River, Sub FlooringInsulation, Pink/Yellow 49683 River, WallsInsulation, Pink/Yellow 52153 Cayuse, WallsVapor Barrier, Black 52153 Cayuse, ShowerCaulk 52153 Cayuse, Windows/DoorsWall Paper, White 52153 Cayuse, KitchenLaminate Flooring 52153 Cayuse, Shop BuildingWall Paneling 52153 Cayuse, Shop BuildingVapor Barrier, Black 52153 Cayuse, Roofing

1.7April 2021

Project No.: 67796.000 Phase No.: 0001

Confederated Tribes of the Umatilla Indian Reservation

INSPECTION SUMMARY

Pendleton, OR CTUIR-FEMA Mitigation Grant ManagementAsbestos Survey Report

Gypsum Wallboard/Joint Compound 52277 Cayuse, Interior WallsMortar 52277 Cayuse, Fireplace/StoveResidual Wall Panel Mastic, Yellow 52277 Cayuse, KitchenCaulk 52277 Cayuse, Windows/DoorsVapor Barrier, Black 52277 Cayuse, RoofingCovebase/Mastic, Gray 52277 Cayuse, Shop TrailerInsulation, Yellow 52277 Cayuse, WallsCarpet and Foam 52277 Cayuse, FlooringInsulation, White/Yellow 53017 Cayuse, Walls/CeilingDuct Vent Tape, Silver 53017 Cayuse, DuctMortar 53017 Cayuse, FireplaceCountertop/Mastic 53017 Cayuse, BathroomsCaulk, Bathroom 53017 Cayuse, BathroomsCaulk, Exterior 53017 Cayuse, Windows/DoorsVapor Barrier, Black 53017 Cayuse, RoofingCementitious Roof Shingles 53017 Cayuse, RoofingWood-Patterned Sheet Floor Covering 53017 Cayuse, Studio FloorCovebase/Mastic, Brown 53017 Cayuse, Studio

1.8April 2021

Project No.: 67796.000 Phase No.: 0001

Confederated Tribes of the Umatilla Indian Reservation

INSPECTION SUMMARY

Pendleton, OR CTUIR-FEMA Mitigation Grant ManagementAsbestos Survey Report

On April 12, 2021 to April 16, 2021, PBS performed pre-demolition hazardous materials surveys of all structures located at 73479 Sampson Ln, 73499 Sampson Ln, 49587 River Rd, 49591 River Rd, and 49683 River Rd of Pendleton, Oregon and 52153 Cayuse Rd, 52277 Cayuse Rd, and 53017 Cayuse Rd of Adams, Oregon. The survey was requested by CTUIR, represented by Wenaha Group, Inc., in anticipation of demolition of the structures.

The purpose of the survey was to locate, identify, and quantify accessible friable and non-friable hazardous building materials for removal prior to demolition.

The survey is also intended to satisfy Occupational Safety and Health Administration (OSHA) hazard communication requirements as well as requirements by the Department of Environmental Quality (DEQ) to perform an asbestos inspection prior to renovation or demolition activities under Oregon Administrative Rule (OAR) 340-248-0270.

Site structures are identified in bid documents as S.01 through S.49. Please refer to Drawing Sheets 1 through 6 and Appendix A of the Environmental Inventory Report for the Project prepared by PBS, dated April 30, 2021 for locations of and further details regarding site structures, respectively

BACKGROUND

1.9April 2021

Project No.: 67796.000 Phase No.: 0001

Confederated Tribes of the Umatilla Indian Reservation

INSPECTION SUMMARY

Pendleton, OR CTUIR-FEMA Mitigation Grant ManagementAsbestos Survey Report

The structures on each of the eight properties were inspected by a PBS Asbestos Hazard Emergency Response Act (AHERA) accredited inspector to determine the presence, location, and approximate quantity of asbestos-containing materials (ACM). Three hundred and eleven bulk samples of building materials, suspected of containing asbestos, were collected and submitted under chain of custody to Lab/Cor Portland Inc. of Portland, Oregon, for polarized light microscopy (PLM) analysis. The following materials were found to contain asbestos:

73479 Sampson Lane, Pendleton, OR:⦁ Asbestos-containing, white, window frame caulk was discovered along the original exterior window

frames of the main residence (S.13).⦁ Asbestos-containing, red, vinyl floor tile was discovered in the northwest bedroom as well as concealed

below the wood flooring in the kitchen and dining area of the main residence (S.13).⦁ Asbestos-containing wall texture was discovered along the gypsum wallboard of the interior walls of the

main residence (S.13).⦁ Asbestos-containing joint compound is associated with all gypsum wallboard assemblies. Seven samples

of the gypsum wallboard were collected. Five of the seven samples contain asbestos, and it should be presumed that all of the joint compound likely contains asbestos within the main residence (S.13).

⦁ Asbestos-containing, white/tan, vinyl floor tile was discovered in the northwest bedroom of the mainresidence (S.13).

⦁ Asbestos-containing, gray, vinyl floor tile was discovered in the northwest bathroom of the mainresidence (S.13).

73499 Sampson Lane, Pendleton, OR:⦁ Asbestos-containing, orange, sheet vinyl flooring with brown mastic was discovered in the southeast

bathroom of the main residence (S.02). ⦁ Asbestos-containing joint compound is associated with all gypsum wallboard assemblies. Seven samples

of the gypsum wallboard were collected. Four of the seven samples contain asbestos, and it should be presumed that all of the joint compound likely contains asbestos within the main residence (S.02).

⦁ Asbestos-containing, gray, sheet vinyl flooring with brown mastic was discovered in the kitchen area ofthe main residence (S.02).

⦁ Asbestos-containing, gray sink undercoating is associated with the metal sink in the kitchen of the mainresidence (S.02).

49587 River Road, Pendleton, OR:⦁ None of the materials sampled at this property were found to contain asbestos.

1.10April 2021

Project No.: 67796.000 Phase No.: 0001

Confederated Tribes of the Umatilla Indian Reservation

INSPECTION SUMMARY

Pendleton, OR CTUIR-FEMA Mitigation Grant ManagementAsbestos Survey Report

49591 River Road, Pendleton, OR:⦁ Asbestos-containing wall texture was discovered associated with the white, floral, wallpaper on the

original gypsum wall board assembly in the east kitchen hallway of the main residence (S.24).

49683 River Road, Pendleton, OR:⦁ Asbestos-containing, black, roofing mastic was discovered associated with the cementitious roof shingles

along the exterior of the main residence (S.28).⦁ Asbestos-containing, residual, black/white exterior panel tar/adhesive was discovered along the south

exterior wall of the shop building/garage (S.27).

52153 Cayuse Road, Adams, OR:⦁ Asbestos-containing joint compound is associated with all gypsum wallboard assemblies. Five samples of

the gypsum wallboard were collected. Two of the five samples contain asbestos, and it should be presumed that all of the joint compound likely contains asbestos within the main residence (S.34).

52277 Cayuse Road, Adams, OR:⦁ Asbestos-containing, brown, sheet vinyl flooring with brown mastic was discovered along the flooring of

the interior well room within the main residence (S.37). ⦁ Asbestos-containing, black, tar/sealant was discovered along all interior and exterior log cabin style walls

of the main residence (S.37) and the mother-in-law unit (S.38).⦁ Asbestos-containing, brown/pebbled, sheet vinyl flooring with yellow mastic was discovered along the

flooring of the trailer associated with the shop building (S.39).⦁ Asbestos-containing, black, spray-on ceiling texture was discovered along the ceiling of the trailer

associated with the shop building (S.39).

53017 Cayuse Road, Adams, OR:⦁ Asbestos-containing wall texture was discovered along the gypsum wallboard of the interior walls of the

main residence (S.46).⦁ Asbestos-containing, white, spray-on, “popcorn” ceiling texture was observed along the ceiling

throughout the main residence (S.46).⦁ Asbestos-containing, beige, sheet vinyl flooring with yellow mastic was discovered concealed below the

wood panel flooring in the southeast bathroom of the main residence (S.02).

Please refer to the asbestos bulk sample inventory for more sample details.

1.11April 2021

Project No.: 67796.000 Phase No.: 0001

Confederated Tribes of the Umatilla Indian Reservation

INSPECTION SUMMARY

Pendleton, OR CTUIR-FEMA Mitigation Grant ManagementAsbestos Survey Report

Asbestos Regulations Oregon DEQ, Environmental Protection Agency (EPA), and OSHA regulations require proper removal and handling of ACM by licensed and trained asbestos abatement contractors prior to building renovations or demolition.

The EPA, DEQ, and OSHA all define ACM as any material containing more than 1% asbestos. Although materials equal to or less than 1% are not considered by regulatory agencies to be an ACM, they still have some asbestos content, and Oregon OSHA has specific requirements for situations in which workers may encounter, disturb, or remove materials containing any level of asbestos. For the sake of hazard communication, these materials are included in the asbestos-containing materials section of this report.

In 1995, Oregon OSHA adopted 29 Code of Federal Regulations (CFR) Part 1926.1101 governing asbestos under OAR 437-003-1926.1101. The regulation has made significant changes in work procedures and how asbestos materials are managed. OSHA believes that the single biggest risk of asbestos exposure is to workers who unknowingly or improperly disturb ACM. Hazard communication, training, personal protection, work practices, exposure monitoring, and recordkeeping are all major components of the regulation.

DEQ’s OAR 340, Division 248 also covers asbestos abatement requirements, removal notifications, licensing, and certifications for contractors.

For more information regarding the removal of asbestos-containing materials, please refer to the following:

1. Oregon Occupational Safety and Health Administration, OAR 437-003-1926.11012. Department of Environmental Quality, OAR-340, Division 248

1.12April 2021

Project No.: 67796.000 Phase No.: 0001

Confederated Tribes of the Umatilla Indian Reservation

INSPECTION SUMMARY

Pendleton, OR CTUIR-FEMA Mitigation Grant ManagementAsbestos Survey Report

LEAD SUMMARYPaint was sampled for lead content for the sake of hazard identification and communication.

Fifty-seven paint chip samples were collected from representative building components from the eight surveyed properties and submitted under chain of custody to RJ Lee Group of Monroeville, Pennsylvania, for analysis of lead content via flame atomic absorption (FLAA).

73479 Sampson Lane, Pendleton, OR:The concentration of lead in the samples range from less than 100 parts per million (ppm) to 2,110 ppm.

73499 Sampson Lane, Pendleton, OR:The concentration of lead in the samples range from less than 130 parts per million (ppm) to 3,320 ppm.

49587 River Road, Pendleton, OR:The concentration of lead in the samples range from less than 100 parts per million (ppm) to less than 220 ppm.

49591 River Road, Pendleton, OR:The concentration of lead in the samples range from less than 100 parts per million (ppm) to less than 1,050 ppm.

49683 River Road, Pendleton, OR:The concentration of lead in the samples range from less than 250 parts per million (ppm) to less than 1,500 ppm.

52153 Cayuse Road, Adams, OR:The concentration of lead in the samples range from less than 100 parts per million (ppm) to less than 350 ppm.

52277 Cayuse Road, Adams, OR:The concentration of lead in the samples range from less than 290 parts per million (ppm) to 55,600 ppm.

53017 Cayuse Road, Adams, OR:The concentration of lead in the samples range from less than 100 parts per million (ppm) to less than 390 ppm.

See the lead sample inventory section for representative building components and corresponding results.

Paint testing for this survey was limited in scope. The report information and testing results are not to be construed as an exhaustive investigation of lead-containing paint on all building surfaces. All paint on painted surfaces not identified in this report should be presumed to contain lead.

1.13April 2021

Project No.: 67796.000 Phase No.: 0001

Confederated Tribes of the Umatilla Indian Reservation

Pendleton, OR CTUIR-FEMA Mitigation Grant ManagementAsbestos Survey Report

INSPECTION SUMMARY

Lead-Containing Paint RegulationsThe Consumer Product Safety Commission limit for lead in consumer paint products is 0.009% or 90 parts per million (ppm) or greater. The Department of Housing and Urban Development (HUD) and the EPA define lead-based paint as that which contains 0.5% or 5,000 ppm. Under OSHA, any lead concentration in paint that may become airborne during construction operations triggers requirements in the OSHA Lead in Construction

In 1993, Oregon OSHA adopted the federal OSHA Lead Standard for the Construction Industry Title 29 CFR 1926.62 under Oregon Administrative Rule 437 Division 3 1926.62. This standard outlines worker exposure limits, personal protection requirements, and employer responsibility for exposure assessment, training, housekeeping, and recordkeeping. OSHA’s lead standard applies to all work where employees may be exposed to lead in construction, alteration, or repair activities. This includes demolition or renovation of structures where lead-containing materials are present.

DisposalAccording to Oregon DEQ’s Hazardous Waste/Toxics Reduction Policy Clarification, disposal of building demolition waste coated with lead-based paint generally will not require a hazardous waste determination (i.e., toxicity characteristic leaching procedures [TCLP] testing) if demolition debris is disposed of at a DEQ-permitted solid waste landfill that meets the current design standards for municipal solid waste disposal facilities of 40 CFR Part 258.

Refer to the DEQ hazardous waste reduction policy and follow all requirements under the Oregon DEQ, Management of Building Demolition Waste, 97-002A for proper disposal of lead-based painted demolition waste

1.14April 2021

Project No.: 67796.000 Phase No.: 0001

Confederated Tribes of the Umatilla Indian Reservation

INSPECTION SUMMARY

Pendleton, OR CTUIR-FEMA Mitigation Grant ManagementAsbestos Survey Report

1.15April 2021

Project No.: 67796.000 Phase No.: 0001

Confederated Tribes of the Umatilla Indian Reservation

Polychlorinated Biphenyls (PCBs)/Mercury InvestigationPBS conducted a visual inspection of the residences for suspect PCB lamp ballasts, mercury-containing fluorescent lamp tubes, and mercury-containing thermostat switches.

73479 Sampson Lane, Pendleton, OR:Approximately four bulbs and ballasts were observed within the east area of the main residence (S.13).

73499 Sampson Lane, Pendleton, OR:Approximately two bulbs and ballasts were observed within the canning shed/pumphouse (S.08).

49587 River Road, Pendleton, OR:Approximately twenty-seven bulbs and ballasts were observed within the shop building (S.21).

49591 River Road, Pendleton, OR:Approximately eight bulbs and ballasts were observed within the shop building (S.23)

49683 River Road, Pendleton, OR:PBS did not observe any bulbs or ballasts at 49683 River Road.

52153 Cayuse Road, Adams, OR:PBS did not observe any bulbs or ballasts at 52153 Cayuse Road.

52277 Cayuse Road, Adams, OR:Approximately eight bulbs and ballasts were observed within the shop building (S.39).

53017 Cayuse Road, Adams, OR:Approximately eight bulbs and ballasts were observed within the studio building (S.49).

This investigation was a visual assessment only; no samples were collected.

PCBs/MERCURY VAPOR TUBES

INSPECTION SUMMARY

Pendleton, OR CTUIR-FEMA Mitigation Grant ManagementAsbestos Survey Report

1.16April 2021

Project No.: 67796.000 Phase No.: 0001

Confederated Tribes of the Umatilla Indian Reservation

Mercury-Containing Compact Fluorescent Light Tubes/Switches Regulatory IssuesAll mercury-containing compact fluorescent light bulbs and switches should be carefully handled, packaged, and recycled or disposed of in the appropriate manner.

Please refer to the following documents for requirements for removal and disposal of mercury-containing waste:⦁ US Environmental Protection Agency Toxic Substance Control Act, TSCA, (Code of Federal Regulations

Title 40, Part 761).⦁ RCRA, Resource Conservation and Recovery Act, 40 CFR Part 2761, Subpart D., 40 CFR 273.

This report is not suitable as a bid document or an asbestos abatement design. The purpose of this report is risk hazard communication only.

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

73479 Sampson, Roof EMC Labs67796.000-0001 Cementitious Roof Shingles

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedShingle, Black/ Gray

Layer 2 No Asbestos DetectedTar, Black Note: Difficult to

separate adjacent layer

73479 Sampson, Roof EMC Labs67796.000-0002 Cementitious Roof Shingles

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedShingle, Black/ Gray

Layer 2 No Asbestos DetectedTar, Black Note: Difficult to

separate adjacent layer

73479 Sampson, Exterior Walls EMC Labs67796.000-0003 Insulation

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedSiding, Black/ Green

Layer 2 No Asbestos DetectedInsulation, Tan

Layer 3 No Asbestos DetectedVapor Barrier, Black

73479 Sampson, Exterior Walls EMC Labs67796.000-0004 Insulation

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedSiding, Black/ Green

Layer 2 No Asbestos DetectedInsulation, Tan

Layer 3 No Asbestos DetectedVapor Barrier, Black

73479 Sampson, West Ext. Window EMC Labs67796.000-0005 Caulk

Analysis:Description:Layer:

Layer 1 3% ChrysotileWindow Caulk, White/ Gray

73479 Sampson, South Ext. Window EMC Labs67796.000-0006 Caulk

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedWindow Caulk, White/ Gray

73479 Sampson, Ceiling EMC Labs67796.000-0007 Spray-on Ceiling

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedDrywall, Off White/ Brown

Layer 2 No Asbestos DetectedJoint Compound, White/ Off

White

Layer 3 No Asbestos DetectedPopcorn Texture, White/ Off

White

2. 1

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

73479 Sampson, Ceiling EMC Labs67796.000-0008 Spray-on Ceiling

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedDrywall, Off White/ Brown

Layer 2 No Asbestos DetectedPopcorn Texture, White/ Off

White

73479 Sampson, Ceiling EMC Labs67796.000-0009 Spray-on Ceiling

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedDrywall, Off White/ Brown

Layer 2 No Asbestos DetectedJoint Compound, White/ Off

White

Layer 3 No Asbestos DetectedPopcorn Texture, White/ Off

White

73479 Sampson, Ceiling EMC Labs67796.000-0010 Spray-on Ceiling

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedDrywall, Off White/ Brown

Layer 2 No Asbestos DetectedPopcorn Texture, White/ Off

White

73479 Sampson, Ceiling EMC Labs67796.000-0011 Spray-on Ceiling

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedDrywall, Off White/ Brown

Layer 2 No Asbestos DetectedPopcorn Texture, White/ Off

White

73479 Sampson, Kitchen EMC Labs67796.000-0012 Vinyl Floor Tile, Red

Analysis:Description:Layer:

Layer 1 3% Chrysotile12" Floor Tile, Red

Layer 2 No Asbestos DetectedMastic, Yellow

73479 Sampson, Kitchen EMC Labs67796.000-0013 Vinyl Floor Tile, Red

Analysis:Description:Layer:

Layer 1 3% Chrysotile12" Floor Tile, Red

Layer 2 No Asbestos DetectedMastic, Yellow

73479 Sampson, Stove EMC Labs67796.000-0014 Mortar

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedBrick, Red

Layer 2 No Asbestos DetectedMortar, Gray

2. 2

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

73479 Sampson, Wall EMC Labs67796.000-0015 Mortar

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedRock, Tan

Layer 2 No Asbestos DetectedMortar, Gray

73479 Sampson, Kitchen EMC Labs67796.000-0016 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedDrywall, Off White/ Brown

Layer 2 No Asbestos DetectedJoint Compound, White/ Off

White

Layer 3 2% ChrysotileTexture, White/ Off White

73479 Sampson, SW Bedroom EMC Labs67796.000-0017 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedDrywall, Off White/ Brown

Layer 2 2% ChrysotileJoint Compound, White/ Off

White

Layer 3 2% ChrysotileTexture, White/ Off White

73479 Sampson, NE Bathroom EMC Labs67796.000-0018 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedDrywall, Off White/ Brown

Layer 2 3% ChrysotileJoint Compound, White/ Off

White

73479 Sampson, Hallway EMC Labs67796.000-0019 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedDrywall, Off White/ Brown

Layer 2 No Asbestos DetectedJoint Compound, White/ Off

White

73479 Sampson, NE Bedroom EMC Labs67796.000-0020 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedDrywall, Off White/ Brown

Layer 2 5% ChrysotileTexture, White/ Off White

2. 3

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

73479 Sampson, East Storage EMC Labs67796.000-0021 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedDrywall, Off White/ Brown

Layer 2 3% ChrysotileJoint Compound, White/ Off

White

Layer 3 No Asbestos DetectedTexture, White/ Off White

73479 Sampson, East Storage EMC Labs67796.000-0022 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedDrywall, Off White/ Brown

Layer 2 No Asbestos DetectedTexture, White/ Off White

73479 Sampson, East Storage EMC Labs67796.000-0023 Textured Paint

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedSpray-On Texture, White/ Off

White

73479 Sampson, Main Entry EMC Labs67796.000-0024 Sheet Floor Covering

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedSheet Vinyl, White/ Gray

Layer 2 No Asbestos DetectedMastic, White/ Gray

73479 Sampson, Main Entry EMC Labs67796.000-0025 Sheet Floor Covering

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedSheet Vinyl, White/ Gray

Layer 2 No Asbestos DetectedMastic, White/ Gray

73479 Sampson, Dining Area Walls EMC Labs67796.000-0026 Troweled Textured Material

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedFiberboard, Beige/ Lt. Green

Layer 2 2% ChrysotileTexture/ Paint, White/ Off

White Note: Difficult to

separate adjacent layers

Layer 3 No Asbestos DetectedInsulation, Gray

2. 4

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

73479 Sampson, Dining Area Walls EMC Labs67796.000-0027 Troweled Textured Material

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedFiberboard, Beige/ Lt. Green

Layer 2 3% ChrysotileTexture/ Paint, White/ Off

White Note: Difficult to

separate adjacent layers

Layer 3 No Asbestos DetectedInsulation, Gray

73479 Sampson, NW Bedroom EMC Labs67796.000-0028 Vinyl Floor Tile, Red

Analysis:Description:Layer:

Layer 1 5% Chrysotile12" Floor Tile, Red

Layer 2 No Asbestos DetectedMastic, Yellow

73479 Sampson, NW Bedroom EMC Labs67796.000-0029 Vinyl Floor Tile, Red

Analysis:Description:Layer:

Layer 1 5% Chrysotile12" Floor Tile, Red

Layer 2 No Asbestos DetectedMastic, Yellow

73479 Sampson, NW Bedroom EMC Labs67796.000-0030 Vinyl Floor Tile, White/Tan

Analysis:Description:Layer:

Layer 1 3% Chrysotile12" Floor Tile, White/ Tan

Layer 2 No Asbestos DetectedMastic, Yellow

73479 Sampson, NW Bedroom EMC Labs67796.000-0031 Vinyl Floor Tile, White/Tan

Analysis:Description:Layer:

Layer 1 3% Chrysotile12" Floor Tile, White/ Tan

Layer 2 No Asbestos DetectedMastic, Yellow

73479 Sampson, Interior Duct EMC Labs67796.000-0032 Duct Felt Tape

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedTape, Silver

Layer 2 No Asbestos DetectedMastic, Clear/ Yellow

73479 Sampson, Kitchen EMC Labs67796.000-0033 Troweled Textured Material

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedMastic, Black

Layer 2 2% ChrysotileTexture, White/ Off White

Layer 3 No Asbestos DetectedFiber Board, Beige/ Tan

2. 5

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

73479 Sampson, SW Bedroom EMC Labs67796.000-0034 Flooring Mastic, Brown

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedFlooring, Gray/ Tan

Layer 2 No Asbestos DetectedMastic, Brown

73479 Sampson, SW Bedroom EMC Labs67796.000-0035 Flooring Mastic, Brown

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedFlooring, Brown/ Tan

Layer 2 No Asbestos DetectedMastic, Brown/ Black

73479 Sampson, West Hallway EMC Labs67796.000-0036 Snap-On Flooring

Analysis:Description:Layer:

Layer 1 No Asbestos Detected10" Snap Tile, Lt. Gray

Layer 2 No Asbestos DetectedMastic, Brown

Layer 3 No Asbestos DetectedVapor Barrier/ Sheet Vinyl,

Black/ Lt. Brown

Layer 4 No Asbestos DetectedMastic, Brown

73479 Sampson, West Hallway EMC Labs67796.000-0037 Snap-On Flooring

Analysis:Description:Layer:

Layer 1 No Asbestos Detected10" Snap Tile, Lt. Gray

Layer 2 No Asbestos DetectedVapor Barrier/ Sheet Vinyl,

Black/ Lt. Brown

Layer 3 No Asbestos DetectedMastic, Brown

73479 Sampson, NW Bathroom EMC Labs67796.000-0038 Vinyl Floor Tile, Gray

Analysis:Description:Layer:

Layer 1 3% Chrysotile12"x12" VFT, Gray

Layer 2 No Asbestos DetectedMastic, Yellow

73479 Sampson, NW Bathroom EMC Labs67796.000-0039 Vinyl Floor Tile, Gray

Analysis:Description:Layer:

Layer 1 3% Chrysotile12"x12" VFT, Gray

Layer 2 No Asbestos DetectedMastic, Yellow

73479 Sampson, West Bathtub EMC Labs67796.000-0040 Mastic

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedPanel, Black/ Tan

Layer 2 No Asbestos DetectedMastic, Brown

Layer 3 No Asbestos DetectedCaulking, White

2. 6

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

73479 Sampson, West Bathtub EMC Labs67796.000-0041 Caulk, White

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCaulk, White

73479 Sampson, Living Room EMC Labs67796.000-0042 Carpet/Mastic

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCarpet, Lt. Gray

Layer 2 No Asbestos DetectedMastic, Lt. Gray

Layer 3 No Asbestos DetectedLinoleum, Lt. Brown

Layer 4 No Asbestos DetectedMastic/ Leveling Compound,

Brown/ Gray

73479 Sampson, Living Room EMC Labs67796.000-0043 Carpet/Mastic

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCarpet, Lt. Gray

Layer 2 No Asbestos DetectedMastic, Lt. Gray

Layer 3 No Asbestos DetectedLinoleum, Lt. Brown

Layer 4 No Asbestos DetectedMastic/ Leveling Compound,

Brown/ Gray

73479 Sampson, NE Bedroom EMC Labs67796.000-0044 Troweled Textured Material

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedFiber Board, Brown

Layer 2 3% ChrysotileJoint Compound, Off White

Layer 3 2% ChrysotileTexture/ Paint, Off White

73479 Sampson, East Bathroom EMC Labs67796.000-0045 Caulk, White

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCaulk, White

73479 Sampson, East Bathroom EMC Labs67796.000-0046 Flooring/Mastic

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedFlooring, Brown/ Black

Layer 2 No Asbestos DetectedMastic, Clear

Layer 3 No Asbestos DetectedFlooring, Gray

73479 Sampson, East Bathroom EMC Labs67796.000-0047 Flooring/Mastic

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedFlooring, Brown/ Black

Layer 2 No Asbestos DetectedMastic, Clear

2. 7

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

73479 Sampson, East Bedroom EMC Labs67796.000-0048 Carpet/Mastic

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCarpet, Brown/ Black

Layer 2 No Asbestos DetectedMastic, Lt. Gray

Layer 3 No Asbestos DetectedFoam, Lt. Yellow

73479 Sampson, East Bedroom EMC Labs67796.000-0049 Sheet Floor Covering

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedSheet Vinyl, Off White/ Gray

Layer 2 No Asbestos DetectedMastic, Yellow

73479 Sampson, East Bedroom EMC Labs67796.000-0050 Sheet Floor Covering

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedSheet Vinyl, Off White/ Gray

Layer 2 No Asbestos DetectedMastic, Yellow

73479 Sampson, Hallway EMC Labs67796.000-0051 Mortar

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGrout, Black

73479 Sampson, Wood Stove EMC Labs67796.000-0052 Mortar

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedBrick, Tan

Layer 2 No Asbestos DetectedMortar, Off White

73479 Sampson, SE Shed EMC Labs67796.000-0053 Insulation, Pink

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedInsulation, Pink

Layer 2 No Asbestos DetectedVapor Barrier, Black/ Brown

73479 Sampson, SE Shed EMC Labs67796.000-0054 Cementitious Roof Shingles

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedShingle, Gray/ Black

Layer 2 No Asbestos DetectedRoofing Tar, Black

73479 Sampson, NE Shed EMC Labs67796.000-0055 Cementitious Roof Shingles

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedShingle, White/ Black

Layer 2 No Asbestos DetectedVapor Barrier, Black

2. 8

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

73479 Sampson, NE Shed EMC Labs67796.000-0056 Vapor Barrier

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedVapor Barrier, Black

73479 Sampson, SW Shed EMC Labs67796.000-0057 Cementitious Roof Shingles

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedShingle, White/ Black

Layer 2 No Asbestos DetectedTar, Black

76499 Sampson, SE Bathroom EMC Labs67796.000-0058 Sheet Floor Covering, Orange

Analysis:Description:Layer:

Layer 1 15% ChrysotileSheet Vinyl, Orange

Layer 2 2% ChrysotileMastic, Brown Note: Difficult

to separate adjacent layer

76499 Sampson, SE Bathroom EMC Labs67796.000-0059 Sheet Floor Covering, Orange

Analysis:Description:Layer:

Layer 1 15% ChrysotileSheet Vinyl, Orange

Layer 2 2% ChrysotileMastic, Brown Note: Difficult

to separate adjacent layer

76499 Sampson, North Bathroom EMC Labs67796.000-0060 Carpet/Mastic

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCarpet, Brown/ Orange

Layer 2 No Asbestos DetectedSheet Vinyl, Gray/ Black

Layer 3 No Asbestos DetectedMastic, Brown

76499 Sampson, North Bathroom EMC Labs67796.000-0061 Carpet/Mastic

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCarpet, Brown/ Orange

Layer 2 No Asbestos DetectedMastic, Lt. Yellow

Layer 3 No Asbestos DetectedSheet Vinyl, Gray/ Black

Layer 4 No Asbestos DetectedMastic, Brown

76499 Sampson, NE Bedroom EMC Labs67796.000-0062 Vinyl Floor Tile, White

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCarpet, Orange

Layer 2 No Asbestos Detected12"x12" VFT, White

Layer 3 No Asbestos DetectedMastic, Brown

2. 9

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

76499 Sampson, NE Bedroom EMC Labs67796.000-0063 Vinyl Floor Tile, White

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCarpet, Orange

Layer 2 No Asbestos DetectedMastic, Yellow

Layer 3 No Asbestos Detected12"x12" VFT, White

Layer 4 No Asbestos DetectedMastic, Brown

76499 Sampson, NW Bedroom EMC Labs67796.000-0064 Sheet Floor Covering, Blue

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCarpet, Purple

Layer 2 No Asbestos DetectedSheet Vinyl, Blue/ Black

Layer 3 No Asbestos DetectedMastic, Brown

76499 Sampson, NW Bedroom EMC Labs67796.000-0065 Sheet Floor Covering, Blue

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCarpet, Purple

Layer 2 No Asbestos DetectedSheet Vinyl, Blue/ Black

Layer 3 No Asbestos DetectedMastic, Black

76499 Sampson, North Hall EMC Labs67796.000-0066 Vinyl Floor Tile, Gray/Black

Analysis:Description:Layer:

Layer 1 No Asbestos Detected9"x9" VAT, Gray/ Black

Layer 2 No Asbestos DetectedMastic, Brown

Layer 3 No Asbestos DetectedVapor Barrier, Black

Layer 4 No Asbestos DetectedMastic, Brown

76499 Sampson, North Hall EMC Labs67796.000-0067 Vinyl Floor Tile, Gray/Black

Analysis:Description:Layer:

Layer 1 No Asbestos Detected9"x9" VAT, Gray/ Black

Layer 2 No Asbestos DetectedMastic, Brown

Layer 3 No Asbestos DetectedVapor Barrier, Black

76499 Sampson, Wood Stove EMC Labs67796.000-0068 Ceramic Tile/Grout

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedRock, Beige Note: No Mortar

Present

2. 10

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

76499 Sampson, Kitchen EMC Labs67796.000-0069 Sheet Floor Covering

Analysis:Description:Layer:

Layer

Layer 1

30% ChrysotileSheet Vinyl, Gray

Layer

Layer 1

30% ChrysotileResidual Paper Backing, Lt. Gray

Layer

Layer 2

3% ChrysotileMastic, Brown Note: Difficult

to separate adjacent layer

Layer

Layer 2

3% ChrysotileMastic, Yellow

Layer

Layer 3

No Asbestos DetectedSheet Vinyl, Off White

Layer

Layer 3

No Asbestos DetectedSheet Vinyl, Beige/ Black

Layer

Layer 4

No Asbestos DetectedMastic, Brown

Layer

Layer 4

No Asbestos DetectedMastic, Yellow

76499 Sampson, Kitchen EMC Labs67796.000-0070 Sheet Floor Covering

Analysis:Description:Layer:

Layer

Layer 1

30% ChrysotileSheet Vinyl, Gray

Layer

Layer 1

30% ChrysotileResidual Paper Backing, Lt. Gray

Layer

Layer 2

3% ChrysotileMastic, Brown Note: Difficult

to separate adjacent layer

Layer

Layer 2

3% ChrysotileMastic, Yellow

Layer

Layer 3

No Asbestos DetectedSheet Vinyl, Off White

Layer

Layer 3

No Asbestos DetectedSheet Vinyl, Beige/ Black

Layer

Layer 4

No Asbestos DetectedMastic, Brown

Layer

Layer 4

No Asbestos DetectedMastic, Yellow

76499 Sampson, North Foyer EMC Labs67796.000-0071 Carpet/Mastic

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCarpet, Green

Layer 2 No Asbestos DetectedMastic, Lt. Gray

Layer 3 No Asbestos DetectedFoam, Gray

2. 11

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

76499 Sampson, South Kitchen EMC Labs67796.000-0072 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Board, White/

Brown Note: No Joint

Compound Present

76499 Sampson, North Hall EMC Labs67796.000-0073 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Board, White/ Brown

Layer 2 2% ChrysotileJoint Compound, Off White

76499 Sampson, North Hall EMC Labs67796.000-0074 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Board, White/ Brown

Layer 2 2% ChrysotileJoint Compound, Off White

76499 Sampson, N. Dining Room EMC Labs67796.000-0075 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Board, White/ Brown

Layer 2 3% ChrysotileJoint Compound, Off White

76499 Sampson, W. Living Room EMC Labs67796.000-0076 Gypsum Wallboard

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Board, White/

Brown Note: No Joint

Compound or Texture Present

76499 Sampson, W. Living Room EMC Labs67796.000-0077 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Board, White/ Brown

Layer 2 No Asbestos DetectedJoint Compound, Off White

76499 Sampson, NE Bedroom EMC Labs67796.000-0078 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Board, White/ Brown

Layer 2 3% ChrysotileJoint Compound, Off White

2. 12

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

76499 Sampson, Kitchen EMC Labs67796.000-0079 Laminate Counter

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedLaminate Counter, Beige/ Brown

Layer 2 No Asbestos DetectedMastic, Yellow

76499 Sampson, Stove EMC Labs67796.000-0080 Mortar

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedBrick, Off White

Layer 2 No Asbestos DetectedMastic, Lt. Gray

Layer 3 No Asbestos DetectedFiberboard, Gray

76499 Sampson, NE Bedroom EMC Labs67796.000-0081 Vinyl Floor Tile, Green

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCarpet, Lime

Layer 2 No Asbestos DetectedMastic, Yellow

Layer 3 No Asbestos DetectedVAT, Green/ Black

Layer 4 No Asbestos DetectedMastic, Brown

76499 Sampson, NE Bedroom EMC Labs67796.000-0082 Vinyl Floor Tile, Green

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCarpet, Lime

Layer 2 No Asbestos DetectedMastic, Yellow

Layer 3 No Asbestos DetectedVAT, Green/ Black

Layer 4 No Asbestos DetectedMastic, Brown

76499 Sampson, Kitchen EMC Labs67796.000-0083 Sink Undercoating

Analysis:Description:Layer:

Layer 1 10% ChrysotileSink Undercoating, Gray

76499 Sampson, NE Bathtub EMC Labs67796.000-0084 Mastic

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedWall Panel, Brown/ Tan

Layer 2 No Asbestos DetectedMastic, Yellow

76499 Sampson, North Hall EMC Labs67796.000-0085 Duct Felt Tape

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedTape, Silver

Layer 2 No Asbestos DetectedMastic, Clear

2. 13

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

76499 Sampson, SE Shower EMC Labs67796.000-0086 Ceramic Tile/Grout

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCeramic Tile, White

Layer 2 No Asbestos DetectedGrout, White

Layer 3 No Asbestos DetectedMastic, Cream

76499 Sampson, NE Bedroom EMC Labs67796.000-0087 Sheet Floor Covering, White

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedSheet Vinyl, White

Layer 2 No Asbestos DetectedMastic, Lt. Yellow

76499 Sampson, NE Bedroom EMC Labs67796.000-0088 Sheet Floor Covering, White

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedSheet Vinyl, White

Layer 2 No Asbestos DetectedMastic, Lt. Yellow

76499 Sampson, Exterior Window EMC Labs67796.000-0089 Caulk, White

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedWindow Frame Caulk, White

76499 Sampson, Roof EMC Labs67796.000-0090 Cementitious Roof Shingles

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedShingle, Green/ Black

Layer 2 No Asbestos DetectedShingle, Green/ Black

76499 Sampson, Roof EMC Labs67796.000-0091 Cementitious Roof Shingles

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedShingle, Green/ Black

Layer 2 No Asbestos DetectedShingle, Green/ Black

Layer 3 No Asbestos DetectedFelt, Black

76499 Sampson, Pump House EMC Labs67796.000-0092 Insulation, Yellow

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedInsulation, Yellow

Layer 2 No Asbestos DetectedInsulation Tape, Silver

76499 Sampson, Pump House EMC Labs67796.000-0093 Insulation, Yellow

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedInsulation, Yellow

Layer 2 No Asbestos DetectedVapor Barrier, Black/ Brown

2. 14

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

76499 Sampson, Greenhouse EMC Labs67796.000-0094 Caulk, White

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCaulking, White/ Gray

76499 Sampson, Shop EMC Labs67796.000-0095 Insulation, Yellow

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedInsulation, Yellow

Layer 2 No Asbestos DetectedVapor Barrier, Black/ Tan

76499 Sampson, Shop EMC Labs67796.000-0096 Gypsum Wallboard

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedDrywall, Off White/ Brown

Layer 2 No Asbestos DetectedTexture, White/ Off White

76499 Sampson, Shop EMC Labs67796.000-0097 Gypsum Wallboard

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedDrywall, Off White/ Brown

Layer 2 No Asbestos DetectedTexture, White/ Off White

76499 Sampson, Shop EMC Labs67796.000-0098 Insulation, Yellow

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedInsulation, Yellow

Layer 2 No Asbestos DetectedVapor Barrier, Black/ Tan

76499 Sampson, Shop EMC Labs67796.000-0099 Ceramic Tile/Grout

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCeramic Tile, White/ Red

Layer 2 No Asbestos DetectedGrout, Beige/ Gray

76499 Sampson, Shop EMC Labs67796.000-0100 Ceramic Tile/Grout

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCeramic Tile, White/ Red

Layer 2 No Asbestos DetectedGrout, Beige/ Gray

Layer 3 No Asbestos DetectedMastic, White/ Yellow

49587 River, North Interior EMC Labs67796.000-0101 Insulation, Silver

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedInsulation, Silver

2. 15

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

49587 River, East Shower EMC Labs67796.000-0102 Ceramic Tile/Grout

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCeramic Tile, Gray

Layer 2 No Asbestos DetectedGrout, Gray

49587 River, East Shower EMC Labs67796.000-0103 Wall and Ceiling Plaster

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedPlaster, Lt. Gray

49587 River, East Shower EMC Labs67796.000-0104 Wall and Ceiling Plaster

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedPlaster, Lt. Gray

49587 River, East Shower EMC Labs67796.000-0105 Ceramic Tile/Grout

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCeramic Tile, Gray

Layer 2 No Asbestos DetectedGrout, Gray

49587 River, Interior Wall EMC Labs67796.000-0106 Insulation Foam

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedFoam, White/ Yellow

49587 River, Interior Window EMC Labs67796.000-0107 Vapor Barrier, Black

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedVapor Barrier, Black

49587 River, Fireplace EMC Labs67796.000-0108 Mortar

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedBrick, Tan

Layer 2 No Asbestos DetectedMortar, Gray

49587 River, West Shower EMC Labs67796.000-0109 Ceramic Tile/Grout

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCeramic Tile, Gray

Layer 2 No Asbestos DetectedGrout, Gray

49587 River, Ceiling EMC Labs67796.000-0110 Duct Felt Tape

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedTape, Silver

Layer 2 No Asbestos DetectedMastic, Yellow

2. 16

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

49587 River, Interior Wall EMC Labs67796.000-0111 Insulation, Yellow

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedInsulation, Yellow

Layer 2 No Asbestos DetectedWrap, White/ Silver

49587 River, Interior Wall EMC Labs67796.000-0112 Insulation, Pink

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedInsulation, Pink

Layer 2 No Asbestos DetectedWrap, Black

49587 River, West Shower EMC Labs67796.000-0113 Ceramic Tile/Grout

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCeramic Tile, Gray/ Beige

Layer 2 No Asbestos DetectedGrout, Gray

49587 River, West Shower EMC Labs67796.000-0114 Fiberboard

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedFiberboard, White/ Gray

49587 River, West Shower EMC Labs67796.000-0115 Wall and Ceiling Plaster

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedPlaster, White/ Gray

49587 River, Exterior Window EMC Labs67796.000-0116 Caulk, Clear

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCaulking, Clear

49587 River, Exterior Siding EMC Labs67796.000-0117 Millboard

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedMillboard, Gray

Layer 2 No Asbestos DetectedVapor Barrier, Gray

49587 River, Roof EMC Labs67796.000-0118 Cementitious Roof Shingles

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedShingle, Black/ Gray

Layer 2 No Asbestos DetectedVapor Barrier, Black

49587 River, Roof EMC Labs67796.000-0119 Cementitious Roof Shingles

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedShingle, Black/ Gray

Layer 2 No Asbestos DetectedVapor Barrier, Black

2. 17

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

49587 River, Exterior Siding EMC Labs67796.000-0120 Millboard

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedMillboard, Gray

Layer 2 No Asbestos DetectedVapor Barrier, Gray

49587 River, Pump House EMC Labs67796.000-0121 Cementitious Roof Shingles

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedShingle, Black/ Gray

Layer 2 No Asbestos DetectedTabletop, Black

Layer 3 No Asbestos DetectedVapor Barrier, Black

49587 River, Pump House EMC Labs67796.000-0122 Insulation, Green

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedWall Insulation, Green

Layer 2 No Asbestos DetectedWrap, Silver

49587 River, Shop EMC Labs67796.000-0123 Insulation, Pink

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedInsulation, Pink

Layer 2 No Asbestos DetectedVapor Barrier, White/ Off White

49587 River, Shop EMC Labs67796.000-0124 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedDrywall, Off White/ Brown

Layer 2 No Asbestos DetectedJoint Compound, White/ Off

White

Layer 3 No Asbestos DetectedTexture, White/ Off White

49587 River, Shop EMC Labs67796.000-0125 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedDrywall, Off White/ Brown

Layer 2 No Asbestos DetectedJoint Compound, White/ Off

White

Layer 3 No Asbestos DetectedTexture, White/ Off White

2. 18

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

49587 River, Shop EMC Labs67796.000-0126 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedDrywall, Off White/ Brown

Layer 2 No Asbestos DetectedJoint Compound, White/ Off

White

Layer 3 No Asbestos DetectedTexture, White/ Off White

49591 River, Laundry EMC Labs67796.000-0127 Ceramic Tile/Grout

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCeramic Grout, Gray

Layer 2 No Asbestos DetectedMastic, Beige/ Lt. Yellow

49591 River, Laundry EMC Labs67796.000-0128 Ceramic Tile/Grout

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCeramic Tile, Lt. Gray/ Gray

Layer 2 No Asbestos DetectedGrout, Gray

Layer 3 No Asbestos DetectedPlaster, Off White

49591 River, Fireplace EMC Labs67796.000-0129 Mortar

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedBrick, Red

Layer 2 No Asbestos DetectedMortar, Brown

49591 River, Fireplace EMC Labs67796.000-0130 Mortar

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedBrick, Red

Layer 2 No Asbestos DetectedMortar, Gray

49591 River, SW Bedroom EMC Labs67796.000-0131 Vinyl Floor Tile, Beige

Analysis:Description:Layer:

Layer 1 No Asbestos Detected9" VAT, Beige

Layer 2 No Asbestos DetectedVapor Barrier, Black

Layer 3 No Asbestos DetectedMastic, Brown

49591 River, E. Kitchen Hall EMC Labs67796.000-0132 Troweled Textured Material

Analysis:Description:Layer:

Layer 1 3% ChrysotileWall Texture/ Paint, Beige

2. 19

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

49591 River, Living Room EMC Labs67796.000-0133 Ceramic Tile/Grout, Wht.

Analysis:Description:Layer:

Layer 1 No Asbestos Detected12" Ceramic Tile, White/ Lt. Gray

Layer 2 No Asbestos DetectedGrout, Gray

Layer 3 No Asbestos DetectedCement, Lt. Gray

49591 River, W. Foyer EMC Labs67796.000-0134 Ceramic Tile/Grout, Blue

Analysis:Description:Layer:

Layer 1 No Asbestos Detected2" Ceramic Tile, Blue/ Lt. Gray

Layer 2 No Asbestos DetectedGrout, Gray

Layer 3 No Asbestos DetectedMastic, Beige

49591 River, Laundry EMC Labs67796.000-0135 Ceramic Tile/Grout, Blue

Analysis:Description:Layer:

Layer 1 No Asbestos Detected2" Ceramic Tile, Blue/ Lt. Gray

Layer 2 No Asbestos DetectedGrout, Gray

Layer 3 No Asbestos DetectedMastic, Beige

49591 River, W. Foyer EMC Labs67796.000-0136 Ceramic Tile/Grout, Gray

Analysis:Description:Layer:

Layer 1 No Asbestos Detected12" Ceramic Tile, Gray/

Red Note: No Grout Present

Layer 2 No Asbestos DetectedMastic, Beige

49591 River, W. Foyer EMC Labs67796.000-0137 Ceramic Tile/Grout, Gray

Analysis:Description:Layer:

Layer 1 No Asbestos Detected12" Ceramic Tile, Gray/

Red Note: No Grout Present

Layer 2 No Asbestos DetectedMastic, Beige

49591 River, S. Family Room EMC Labs67796.000-0138 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Board, White/ Brown

Layer 2 No Asbestos DetectedJoint Compound, Off White

Layer 3 No Asbestos DetectedTexture/ Paint, Off White/ White

49591 River, N. Family Room EMC Labs67796.000-0139 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Board, White/ Brown

Layer 2 No Asbestos DetectedJoint Compound, Off White/

White

2. 20

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

49591 River, W. Kitchen EMC Labs67796.000-0140 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Board, White/ Brown

Layer 2 No Asbestos DetectedJoint Compound, Off White/

White

49591 River, S. Bathroom EMC Labs67796.000-0141 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Board, White/ Brown

Layer 2 No Asbestos DetectedJoint Compound, Off White/

White

49591 River, N. Bathroom EMC Labs67796.000-0142 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Board, White/ Brown

Layer 2 No Asbestos DetectedJoint Compound, Off White

49591 River, NE Room EMC Labs67796.000-0143 Vapor Barrier, Black

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedVapor Barrier Paper, Black/

Brown

49591 River, S. Family Room EMC Labs67796.000-0144 Mastic, Cream

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedFloor Mastic, Cream

49591 River, SW Room EMC Labs67796.000-0145 Vinyl Floor Tile, Beige

Analysis:Description:Layer:

Layer 1 No Asbestos Detected9" VAT, Beige

Layer 2 No Asbestos DetectedVapor Barrier, Black

Layer 3 No Asbestos DetectedMastic, Brown

49591 River, NE Room EMC Labs67796.000-0146 Ceramic Tile/Grout, Gray

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCeramic Tile Grout, Gray

2. 21

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

49591 River, S. Bathroom EMC Labs67796.000-0147 Ceramic Tile/Grout

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCeramic Tile, White/ Off White

Layer 2 No Asbestos DetectedGrout, Gray

Layer 3 No Asbestos DetectedMastic, Cream

49591 River, Wood Stove EMC Labs67796.000-0148 Mortar

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedBrick, Red

Layer 2 No Asbestos DetectedMortar, Gray

49591 River, SE Room EMC Labs67796.000-0149 Insulation, Brown

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedWall Insulation, Brown

Layer 2 No Asbestos DetectedVapor Barrier, Silver/ Black

49591 River, S. Bathroom EMC Labs67796.000-0150 Insulation, Pink

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedWall Insulation, Pink

49591 River, South Bedroom EMC Labs67796.000-0151 Insulation, Brown

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedWall Insulation, Brown

Layer 2 No Asbestos DetectedVapor Barrier, Silver/ Black

49591 River, Living Room EMC Labs67796.000-0152 Mastic, Yellow

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedDot Mastic, Yellow/ Tan

49591 River, Living Room EMC Labs67796.000-0153 Mastic, Yellow

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedDot Mastic, Yellow/ Tan

49591 River, S. Hallway Floor EMC Labs67796.000-0154 Vapor Barrier, Black

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedVapor Barrier, Black

49591 River, SE Room, Floor EMC Labs67796.000-0155 Vapor Barrier, Black

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedVapor Barrier, Black

2. 22

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

49591 River, Exterior Wall EMC Labs67796.000-0156 Ceramic Tile Grout

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedRock Wall Grout, Gray

49591 River, Exterior Door EMC Labs67796.000-0157 Caulk, Green/Clear

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedDoor Frame Caulk, Green/ Clear

49591 River, Exterior Door EMC Labs67796.000-0158 Caulk, Green/White

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedDoor Frame Caulk, Green/

White

49591 River, Roof EMC Labs67796.000-0159 Cementitious Roof Shingles

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedShingle/ Tar, Black

49591 River, Roof EMC Labs67796.000-0160 Cementitious Roof Shingles

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedShingle/ Tar, Black

49591 River, Mother-in-Law, Stove EMC Labs67796.000-0161 Ceramic Tile/Grout, Brown

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCeramic Tile, Dk. Brown/ Gray

Layer 2 No Asbestos DetectedCement, Off White

49591 River, Mother-in-Law, Shower EMC Labs67796.000-0162 Ceramic Tile/Grout, Green

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCeramic Tile, Lt. Green/ Gray

Layer 2 No Asbestos DetectedCement, Off White

49591 River, Mother-in-Law EMC Labs67796.000-0163 Ceramic Tile/Grout, Lt. Green

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCeramic Tile, Lt. Green/ Gray

Layer 2 No Asbestos DetectedGrout, Lt. Gray

Layer 3 No Asbestos DetectedCement, Off White

2. 23

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

49591 River, Mother-in-Law EMC Labs67796.000-0164 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedDrywall, Off White/ Brown

Layer 2 No Asbestos DetectedJoint Compound, White/ Off

White

49591 River, Mother-in-Law EMC Labs67796.000-0165 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedDrywall, Off White/ Brown

Layer 2 No Asbestos DetectedJoint Compound, White/ Off

White

49591 River, Mother-in-Law EMC Labs67796.000-0166 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedDrywall, Off White/ Brown

Layer 2 No Asbestos DetectedJoint Compound, White/ Off

White

49591 River, Mother-in-Law EMC Labs67796.000-0167 Insulation, Yellow

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedInsulation, Yellow

Layer 2 No Asbestos DetectedVapor Barrier, Black

49591 River, Mother-in-Law EMC Labs67796.000-0168 Ceramic Tile/Grout

Analysis:Description:Layer:

Layer 1 No Asbestos Detected14" Ceramic Tile, Tan

Layer 2 No Asbestos DetectedGrout, Dk. Gray

Layer 3 No Asbestos DetectedMastic, Brown

49591 River, Mother-in-Law EMC Labs67796.000-0169 Fiberboard

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedFiber Board, Off White

Layer 2 No Asbestos DetectedJoint Compound, White

49591 River, Mother-in-Law EMC Labs67796.000-0170 Ceramic Tile/Grout, Beige

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCeramic Tile, Beige

Layer 2 No Asbestos DetectedFiber Board, Off White

Layer 3 No Asbestos DetectedJoint Compound, White

2. 24

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

49591 River, Mother-in-Law, Window EMC Labs67796.000-0171 Caulk, White

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedExterior Window Caulk, White

49591 River, Mother-in-Law EMC Labs67796.000-0172 Insulation, White

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedWall Insulation, White

Layer 2 No Asbestos DetectedVapor Barrier, Black/ Brown

49591 River, SE Shed EMC Labs67796.000-0173 Cementitious Roof Shingles

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedRoof Shingle/ Tar, Black

49591 River, SE Shed, Stove EMC Labs67796.000-0174 Ceramic Tile Grout

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGrout, Gray

49591 River, Pump House EMC Labs67796.000-0175 Cementitious Roof Shingles

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedShingle/ Tar, Black/ Brown

49591 River, Pump House EMC Labs67796.000-0176 Gypsum Wallboard

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Wallboard, White/

Brown Note: No Joint

Compound or Texture Present

49591 River, Shop EMC Labs67796.000-0177 Insulation, Pink

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedFoam Insulation, Pink

49591 River, Shop EMC Labs67796.000-0178 Insulation, Pink

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedFiberglass Insulation, Pink

49591 River, Shop EMC Labs67796.000-0179 Insulation, Yellow

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedFiberglass Insulation, Yellow

Layer 2 No Asbestos DetectedVapor Barrier, White/ Lt. Brown

2. 25

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

49591 River, Shop EMC Labs67796.000-0180 Gypsum Wallboard

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Wallboard, White/

Brown Note: No Joint

Compound or Texture Present

49591 River, Shop EMC Labs67796.000-0181 Gypsum Wallboard

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Wallboard, White/

Brown Note: No Joint

Compound or Texture Present

49683 River, Kitchen EMC Labs67796.000-0182 Fiberboard, White

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedFiber Ceiling, White

49683 River, Laundry EMC Labs67796.000-0183 Fiberboard, White

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedFiber Ceiling, White

49683 River, Bathroom EMC Labs67796.000-0184 Counter Top/Mastic

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCounter Top, White

Layer 2 No Asbestos DetectedMastic, Red

49683 River, Bathroom EMC Labs67796.000-0185 Troweled Textured Material

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedWall Texture, Brown

49683 River, Shower EMC Labs67796.000-0186 Caulk, White

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedShower Caulk, White

49683 River, Living EMC Labs67796.000-0187 Carpet, Cream

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCarpet, Cream

Layer 2 No Asbestos DetectedFoam, Gray/Purple

2. 26

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

49683 River, Kitchen EMC Labs67796.000-0188 Laminate, Brown

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedWood Laminate Floor, Brown

Layer 2 No Asbestos DetectedMastic, Yellow Note: Very

small amount of mastic

49683 River, Laundry EMC Labs67796.000-0189 Sheet Floor Covering, White

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedSheet Vinyl, White

Layer 2 No Asbestos DetectedMastic, Yellow

49683 River, Kitchen EMC Labs67796.000-0190 Laminate, Brown

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedWood Laminate, Brown

Layer 2 No Asbestos DetectedMastic, Yellow/Gray

49683 River, Bathroom EMC Labs67796.000-0191 Sheet Floor Covering, White

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedSheet Vinyl, White

Layer 2 No Asbestos DetectedMastic, Yellow

49683 River, North Bedroom EMC Labs67796.000-0192 Carpet, Tan

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCarpet, Tan Mottled

Layer 2 No Asbestos DetectedFoam, Gray/Blue

49683 River, Sub Floor EMC Labs67796.000-0193 Vapor Barrier, Black

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedVapor Barrier, Black

49683 River, Northwest Exterior EMC Labs67796.000-0194 Fiberboard, Brown

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedFiber Board Panel, Brown

Layer 2 No Asbestos DetectedMastic, Yellow Note: Difficult

to separate adjacent layer

49683 River, Exterior Walls EMC Labs67796.000-0195 Fiberboard, Brown

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedFiber Board Panel, Brown

Layer 2 No Asbestos DetectedMastic, Yellow Note: Difficult

to separate adjacent layer

2. 27

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

49683 River, Northwest Exterior EMC Labs67796.000-0196 Insulation, Yellow

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedInsulation, Yellow

49683 River, Exterior Window EMC Labs67796.000-0197 Caulk, White

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedWindow Frame Caulk, White

49683 River, Roofing EMC Labs67796.000-0198 Cementitious Roof Shingles

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedShingle, Black/ White

Layer 2 5% ChrysotileMastic, Black

49683 River, Roofing EMC Labs67796.000-0199 Cementitious Roof Shingles

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedShingle, Black/ White

Layer 2 5% ChrysotileMastic, Black

49683 River, Shop Building EMC Labs67796.000-0200 Vapor Barrier, Black

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedVapor Barrier, Black

49683 River, Shop Building EMC Labs67796.000-0201 Vapor Barrier, Black

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedVapor Barrier, Black

49683 River, South Shop Exterior EMC Labs67796.000-0202 Residual Tar / Adhesive

Analysis:Description:Layer:

Layer 1 3% ChrysotileTar, Black

Layer 2 <1% ChrysotileCompound, Yellow

49683 River, Shed Roof EMC Labs67796.000-0203 Vapor Barrier, Black

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedRoof Vapor Barrier, Black

52153 Cayuse, Interior Walls EMC Labs67796.000-0204 Insulation, Pink

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedWrap, Brown

Layer 2 No Asbestos DetectedInsulation, Pink

2. 28

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

52153 Cayuse, East Bathroom EMC Labs67796.000-0205 Vapor Barrier, Black

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedVapor Barrier, Black

Layer 2 No Asbestos DetectedTar, Black

52153 Cayuse, N. Family Room EMC Labs67796.000-0206 Wall Paper, White

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedFloral Wall Paper, White

52153 Cayuse, West Interior EMC Labs67796.000-0207 Insulation, Yellow

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedInsulation, Yellow

52153 Cayuse, Interior Wall EMC Labs67796.000-0208 Insulation, Pink

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedWrap Insulation, Silver/Pink

Layer 2 No Asbestos DetectedVapor Barrier, Black

52153 Cayuse, Door Frame EMC Labs67796.000-0209 Caulk

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedDoor /Window Frame Caulk,

Yellow/Green

52153 Cayuse, Roof EMC Labs67796.000-0210 Sealant, Clear

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedPenetration Sealant, Clear

52153 Cayuse, Roof EMC Labs67796.000-0211 Vapor Barrier, Black

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedVapor Barrier Felt, Black

52153 Cayuse, Roof EMC Labs67796.000-0212 Vapor Barrier, Black

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedVapor Barrier Felt, Black

52153 Cayuse, East Bathroom EMC Labs67796.000-0213 Vapor Barrier, Black

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedVapor Barrier, Black

Layer 2 No Asbestos DetectedTar, Black

2. 29

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

52153 Cayuse, N. Interior EMC Labs67796.000-0214 Insulation, Brown

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedInsulation, Brown

Layer 2 No Asbestos DetectedPaper, Off White

52153 Cayuse, Shop Flooring EMC Labs67796.000-0215 Laminate, Gray

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedLaminate Floor Tile, Gray/ Black

Layer 2 No Asbestos DetectedMastic, Yellow

52153 Cayuse, Shop Flooring EMC Labs67796.000-0216 Laminate, Gray

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedLaminate Floor Tile, Gray/ Black

Layer 2 No Asbestos DetectedMastic, Yellow

52153 Cayuse, Shop Door EMC Labs67796.000-0217 Caulk, White

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedDoor Caulk, White

52153 Cayuse, Shop EMC Labs67796.000-0218 Insulation, Yellow

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedInsulation, Yellow

Layer 2 No Asbestos DetectedVapor Barrier, Black/ Brown

52153 Cayuse, Pumphouse EMC Labs67796.000-0219 Insulation, Pink

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedWrap, Silver/ Black/

Brown Note: Difficult to

separate adjacent layer

Layer 2 No Asbestos DetectedInsulation, Pink

52153 Cayuse, Shop Walls EMC Labs67796.000-0220 Wall Paneling

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedVertical Striped Wall Paneling,

Yellow/ Dk. Brown

52153 Cayuse, Shop Garage EMC Labs67796.000-0221 Vapor Barrier, Black

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedRoofing Vapor Bsrrier, Black

2. 30

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

52153 Cayuse, Shop Garage EMC Labs67796.000-0222 Vapor Barrier, Black

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedRoofing Vapor Bsrrier, Black

52153 Cayuse, East Bathroom EMC Labs67796.000-0223 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Wallboard, White/

Brown

Layer 2 No Asbestos DetectedTape, Beige

Layer 3 No Asbestos DetectedJoint Compound, Off White

52153 Cayuse, East Hallway EMC Labs67796.000-0224 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Wallboard, White/

Brown

Layer 2 3% ChrysotileJoint Compound, Off White/ Lt.

Green

52153 Cayuse, Northeast Room EMC Labs67796.000-0225 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Wallboard, White/

Brown

Layer 2 No Asbestos DetectedJoint Compound, Off White

52153 Cayuse, Kitchen Area EMC Labs67796.000-0226 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Wallboard, White/

Brown

Layer 2 3% ChrysotileJoint Compound, Off White/ Lt.

Green

52153 Cayuse, N. Family Room EMC Labs67796.000-0227 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Wallboard, White/

Brown

Layer 2 No Asbestos DetectedTape, Beige

Layer 3 No Asbestos DetectedJoint Compound, White Note:

Difficult to separate adjacent

layer

2. 31

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

52277 Cayuse, Interior Wall EMC Labs67796.000-0228 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Wallboard, White/

Brown

Layer 2 No Asbestos DetectedJoint Compound, White

52277 Cayuse, Kitchen Wall EMC Labs67796.000-0229 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Wallboard, White/

Brown

Layer 2 No Asbestos DetectedJoint Compound, White

52277 Cayuse, Kitchen Wall EMC Labs67796.000-0230 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Wallboard, White/

Brown

Layer 2 No Asbestos DetectedJoint Compound, White

52277 Cayuse, Hall EMC Labs67796.000-0231 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Wallboard, White/

Brown

Layer 2 No Asbestos DetectedJoint Compound, White

Layer 3 No Asbestos DetectedTape, Beige

Layer 4 No Asbestos DetectedJoint Compound, Beige

52277 Cayuse, Laundry EMC Labs67796.000-0232 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Wallboard, White/

Brown

Layer 2 No Asbestos DetectedTape, Beige

Layer 3 No Asbestos DetectedJoint Compound/ Paint, White

52277 Cayuse, Interior Well Room EMC Labs67796.000-0233 Sheet Floor Covering, Brown

Analysis:Description:Layer:

Layer 1 15% ChrysotileSheet Flooring, Brown/ Beige

Layer 2 3% ChrysotileMastic, Brown Note: Difficult

to separate adjacent layer

2. 32

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

52277 Cayuse, Stove Wall EMC Labs67796.000-0234 Insulation, Gray

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedInsulation, Gray

52277 Cayuse, Hearth Area EMC Labs67796.000-0235 Ceramic Tile Grout

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGrout, Gray

52277 Cayuse, Downstairs Main EMC Labs67796.000-0236 Sheet Floor Covering, Gray

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedSheet Vinyl, Gray/ White

Layer 2 No Asbestos DetectedCM Mastic, Yellow

52277 Cayuse, Kitchen EMC Labs67796.000-0237 Wall Panel Mastic, Yellow

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedWainscoting Mastic, Yellow

52277 Cayuse, Interior Wall EMC Labs67796.000-0238 Caulk, White

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCaulk, White

52277 Cayuse, Carpeted Area EMC Labs67796.000-0239 Carpet/Foam

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCarpet Foam, Green/ Yellow

52277 Cayuse, Roof EMC Labs67796.000-0240 Vapor Barrier, Black

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedRoofing Vapor Barrier, Black

52277 Cayuse, Roof EMC Labs67796.000-0241 Vapor Barrier, Black

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedRoofing Vapor Barrier, Black

52277 Cayuse, Log Walls EMC Labs67796.000-0242 Tar / Sealant, Black

Analysis:Description:Layer:

Layer 1 15% ChrysotileTar/Sealant, Black

52277 Cayuse, Log Walls EMC Labs67796.000-0243 Tar / Sealant, Black

Analysis:Description:Layer:

Layer 1 15% ChrysotileTar/Sealant, Black

2. 33

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

52277 Cayuse, West Exterior EMC Labs67796.000-0244 Foam Insulation, Yellow

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedFoam Insulation, Yellow

52277 Cayuse, Window Frame EMC Labs67796.000-0245 Caulk

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedExterior Window Frame Caulk,

Clear

52277 Cayuse, Exterior Door EMC Labs67796.000-0246 Caulk

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedExterior Door Frame Caulk,

Clear

52277 Cayuse, Roof EMC Labs67796.000-0247 Cementitious Roof Shingles

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedRoof Sealant, Green/Black

Layer 2 No Asbestos DetectedRoof Tar, Black

52277 Cayuse, Roof EMC Labs67796.000-0248 Cementitious Roof Shingles

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedRoof Sealant, Green/Black

Layer 2 No Asbestos DetectedRoof Tar, Black

52277 Cayuse, Shop EMC Labs67796.000-0249 Vapor Barrier, White

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedVapor Barrier, White

Layer 2 No Asbestos DetectedTape, Yellow

52277 Cayuse, Shop EMC Labs67796.000-0250 Gypsum Wallboard

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Board Ceiling, White/

Brown

52277 Cayuse, Shop EMC Labs67796.000-0251 Gypsum Wallboard

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Board Ceiling, White/

Brown

2. 34

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

52277 Cayuse, Shop EMC Labs67796.000-0252 Gypsum Wallboard

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Board Ceiling, White/

Brown

52277 Cayuse, Shop Trailer EMC Labs67796.000-0253 Sheet Floor Covering,

Pebbled

Analysis:Description:Layer:

Layer 1 18% ChrysotileSheet Vinyl, Brown/ Mosaic

Layer 2 2% ChrysotileMastic, Yellow

52277 Cayuse, Shop Trailer EMC Labs67796.000-0254 Sheet Floor Covering,

Pebbled

Analysis:Description:Layer:

Layer 1 18% ChrysotileSheet Vinyl, Brown/ Mosaic

Layer 2 2% ChrysotileMastic, Yellow

52277 Cayuse, Shop Trailer EMC Labs67796.000-0255 Spray-on Ceiling, Black

Analysis:Description:Layer:

Layer 1 5% ChrysotileSpray-On, Black

52277 Cayuse, Shop Trailer EMC Labs67796.000-0256 Spray-on Ceiling, Black

Analysis:Description:Layer:

Layer 1 5% ChrysotileSpray-On, Black

52277 Cayuse, Shop Trailer EMC Labs67796.000-0257 Covebase/Mastic, Gray

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCove Base, Gray

Layer 2 No Asbestos DetectedMastic, Yellow

52277 Cayuse, Shop Trailer EMC Labs67796.000-0258 Covebase/Mastic, Gray

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCove Base, Gray

Layer 2 No Asbestos DetectedMastic, Yellow

52277 Cayuse, Mother-in-Law EMC Labs67796.000-0259 Insulation, Yellow

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedFoam Insulation, Yellow

52277 Cayuse, Mother-in-Law Windows EMC Labs67796.000-0260 Caulk, Tan

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedWindow Caulk, Tan

2. 35

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

52277 Cayuse, Mother-in-Law EMC Labs67796.000-0261 Sheet Floor Covering

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedSheet Vinyl, White/ Off

White Note: No Mastic

52277 Cayuse, Mother-in-Law EMC Labs67796.000-0262 Sheet Floor Covering

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedSheet Vinyl, White/ Off

White Note: No Mastic

52277 Cayuse, Mother-in-Law EMC Labs67796.000-0263 Window Glazing Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedWindow Glazing, Off White/

White

52277 Cayuse, Mother-in-Law EMC Labs67796.000-0264 Counter Top, Mastic

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCounter Top, Gray/ Brown

Layer 2 No Asbestos DetectedMastic, Yellow

52277 Cayuse, Mother-in-Law EMC Labs67796.000-0265 Wall Paper, Floral

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedWallpaper, White/ Yellow/

Green

Layer 2 No Asbestos DetectedDrywall, White/ Brown/ Off

White

52277 Cayuse, Mother-in-Law EMC Labs67796.000-0266 Sealant, Gray

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedSealant, Gray

52277 Cayuse, Mother-in-Law EMC Labs67796.000-0267 Vapor Barrier, White

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedVapor Barrier, White

52277 Cayuse, Mother-in-Law EMC Labs67796.000-0268 Tar / Sealant, Black

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedTar/ Sealant, Black

2. 36

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

52277 Cayuse, Mother-in-Law EMC Labs67796.000-0269 Fireplace Mortar

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedBrick, Tan

Layer 2 No Asbestos DetectedMortar, Gray

52277 Cayuse, Mother-in-Law EMC Labs67796.000-0270 Caulk, White

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedLog Caulk, White

52277 Cayuse, Mother-in-Law EMC Labs67796.000-0271 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Wallboard, White/

Brown

Layer 2 No Asbestos DetectedTape, Cream

Layer 3 No Asbestos DetectedJoint Compound, Off White/

White

52277 Cayuse, Mother-in-Law EMC Labs67796.000-0272 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Wallboard, White/

Brown

Layer 2 No Asbestos DetectedTape, Cream

Layer 3 No Asbestos DetectedJoint Compound, Off White/

White

52277 Cayuse, Mother-in-Law EMC Labs67796.000-0273 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Wallboard, White/

Brown

Layer 2 No Asbestos DetectedTape, Cream

Layer 3 No Asbestos DetectedJoint Compound, Off White/

White

52277 Cayuse, Mother-in-Law EMC Labs67796.000-0274 Carpet, Green

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCarpet, Green

52277 Cayuse, Mother-in-Law EMC Labs67796.000-0275 Tar / Sealant, Black

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedLog Tar/ Sealant, Black

2. 37

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

53017 Cayuse, Attic EMC Labs67796.000-0276 Insulation, White

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedWall/ Ceiling Insulation, White

53017 Cayuse, Garage EMC Labs67796.000-0277 Duct Vent Tape, Silver

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedDuct Tape, Silver

53017 Cayuse, Attic EMC Labs67796.000-0278 Insulation, Yellow

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedInsulation, Yellow

53017 Cayuse, SE Bedroom EMC Labs67796.000-0279 Troweled Textured Material

Analysis:Description:Layer:

Layer 1 3% ChrysotileWall Texture, White

53017 Cayuse, SE Bedroom EMC Labs67796.000-0280 Spray-on Ceiling, White

Analysis:Description:Layer:

Layer 1 7% ChrysotilePopcorn Ceiling Texture,

White/ Off White

53017 Cayuse, Family Room EMC Labs67796.000-0281 Spray-on Ceiling, White

Analysis:Description:Layer:

Layer 1 5% ChrysotilePopcorn Ceiling Texture,

White/ Off White

53017 Cayuse, Hallway EMC Labs67796.000-0282 Spray-on Ceiling, White

Analysis:Description:Layer:

Layer 1 5% ChrysotilePopcorn Ceiling Texture,

White/ Off White

53017 Cayuse, Fireplace EMC Labs67796.000-0283 Mortar

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedRock & Grout, Gray

53017 Cayuse, SE Bathroom EMC Labs67796.000-0284 Vapor Barrier

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedSubflooring, Brown

Layer 2 No Asbestos DetectedDebris, Brown

2. 38

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

53017 Cayuse, SE Bathroom EMC Labs67796.000-0285 Sheet Floor Covering, Beige

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedLaminate, Wood Grain/ Brown/

Black Note: Insufficient

Mastic/Adhesive for Analysis

Layer 2 15% ChrysotileSheet Vinyl, Beige/ Off White

Layer 3 3% ChrysotileMastic, Yellow Note: Difficult

to separate adjacent layers

Layer 4 No Asbestos DetectedVapor Barrier, Black

53017 Cayuse, SE Bathroom EMC Labs67796.000-0286 Sheet Floor Covering, Beige

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedLaminate, Wood Grain/ Brown/

Black Note: Insufficient

Mastic/Adhesive for Analysis

Layer 2 15% ChrysotileSheet Vinyl, Beige/ Off White

Layer 3 3% ChrysotileMastic, Yellow Note: Difficult

to separate adjacent layers

Layer 4 No Asbestos DetectedVapor Barrier, Black

53017 Cayuse, SE Bathroom EMC Labs67796.000-0287 Counter Top, Mastic

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCounter Top, Beige/ Brown

Layer 2 No Asbestos DetectedMastic, Yellow

53017 Cayuse, Bathtub EMC Labs67796.000-0288 Caulk

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCaulk, White/ Off White

53017 Cayuse, NW Bathroom EMC Labs67796.000-0289 Ceramic Tile/Grout

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCeramic Grout, Gray

53017 Cayuse, NW Bathroom EMC Labs67796.000-0290 Ceramic Tile/Grout

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedCeramic Grout, Gray

Layer 2 No Asbestos DetectedCeramic Tile, White/ Red

53017 Cayuse, Stall Roof EMC Labs67796.000-0291 Cementitious Roof Shingles

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedShingle, Black/ White/ Green

Layer 2 No Asbestos DetectedTar, Black Note: Vaery small

amount of tar

2. 39

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

53017 Cayuse, Pumphouse EMC Labs67796.000-0292 Insulation, Yellow

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedInsulation Foam, Yellow

53017 Cayuse, Pumphouse EMC Labs67796.000-0293 Vapor Barrier

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedVapor Barrier, Black/ Brown

53017 Cayuse, Pumphouse EMC Labs67796.000-0294 Cementitious Roof Shingles

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedShingle, Black/ White/

Green Note: No Tar Present

53017 Cayuse, East Shed EMC Labs67796.000-0295 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Wallboard, White/

Brown

Layer 2 No Asbestos DetectedJoint Compound, White/ Beige

53017 Cayuse, East Shed EMC Labs67796.000-0296 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Wallboard, White/

Brown

Layer 2 No Asbestos DetectedJoint Compound, Beige

53017 Cayuse, East Shed EMC Labs67796.000-0297 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Wallboard, White/

Brown

Layer 2 No Asbestos DetectedJoint Compound, White

53017 Cayuse, E. Studio Exterior EMC Labs67796.000-0298 Paneling, Red/Gray

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedPaneling, Dk. Red/ Gray

2. 40

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

53017 Cayuse, E. Studio Interior EMC Labs67796.000-0299 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Wallboard, White/

Brown

Layer 2 No Asbestos DetectedJoint Compound, White

53017 Cayuse, E. Studio Interior EMC Labs67796.000-0300 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Wallboard, White/

Brown

Layer 2 No Asbestos DetectedJoint Compound, White

53017 Cayuse, E. Studio Interior EMC Labs67796.000-0301 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Wallboard, White/

Brown

Layer 2 No Asbestos DetectedJoint Compound, White

53017 Cayuse, N. Studio Interior EMC Labs67796.000-0302 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Wallboard, White/

Brown

Layer 2 No Asbestos DetectedJoint Compound, White

53017 Cayuse, N. Studio Interior EMC Labs67796.000-0303 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Wallboard, White/

Brown

Layer 2 No Asbestos DetectedJoint Compound, White

53017 Cayuse, N. Studio Interior EMC Labs67796.000-0304 Gypsum Wallboard/Joint

Compound

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedGypsum Wallboard, White/

Brown

Layer 2 No Asbestos DetectedJoint Compound, White

2. 41

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Bulk Sample Inventory

Code Material Location Lab Results

53017 Cayuse, N. Studio Roof EMC Labs67796.000-0305 Vapor Barrier, Black

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedVapor Barrier, Black/ Brown

53017 Cayuse, E. Studio Flooring EMC Labs67796.000-0306 Sheet Floor Covering,

Grained

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedSheet Vinyl, Brown/

Beige Note: Wood Pattern

Layer 2 No Asbestos DetectedMastic, Tan/ Black

53017 Cayuse, E. Studio Flooring EMC Labs67796.000-0307 Sheet Floor Covering,

Grained

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedSheet Vinyl, Brown/

Beige Note: Wood Pattern

Layer 2 No Asbestos DetectedMastic, Tan/ Black

53017 Cayuse, E. Studio EMC Labs67796.000-0308 Covebase/Mastic, Brown

Analysis:Description:Layer:

Layer 1 No Asbestos Detected4" Cove Base, Brown

Layer 2 No Asbestos DetectedMastic/ Leveling Compound,

Cream/ White Note: Difficult

to separate adjacent layers

53017 Cayuse, E. Studio EMC Labs67796.000-0309 Covebase/Mastic, Brown

Analysis:Description:Layer:

Layer 1 No Asbestos Detected4" Cove Base, Brown

Layer 2 No Asbestos DetectedMastic/ Leveling Compound,

Cream/ White Note: Difficult

to separate adjacent layers

53017 Cayuse, Roof EMC Labs67796.000-0310 Cementitious Roof Shingles

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedShingle, Black/ White/ Green

Layer 2 No Asbestos DetectedTar, Black Note: Vaery small

amount of tar

53017 Cayuse, Roof EMC Labs67796.000-0311 Cementitious Roof Shingles

Analysis:Description:Layer:

Layer 1 No Asbestos DetectedShingle, Black/ White/ Green

Layer 2 No Asbestos DetectedTar, Black Note: Vaery small

amount of tar

2. 42

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Lead Sample Inventory

Code LocationMaterial Analysis Lab

PAINT

73479 Sampson - White, Interior, Brick EMC LabsLB67796.000-1001 Paint < 400 ppm

73479 Sampson - Green, Interior, Wall EMC LabsLB67796.000-1002 Paint < 100 ppm

73479 Sampson - Yellow, Interior, Wall EMC LabsLB67796.000-1003 Paint < 100 ppm

73479 Sampson - White, NW Bedroom, Wall EMC LabsLB67796.000-1004 Paint 310 ppm

73479 Sampson - Blue, Bathroom, Wall EMC LabsLB67796.000-1005 Paint 210 ppm

73479 Sampson - Beige, Interior, Wall EMC LabsLB67796.000-1006 Paint < 260 ppm

73479 Sampson - Brown, Exterior, Wall EMC LabsLB67796.000-1007 Paint 2,110 ppm

73479 Sampson - Brown, Exterior Shed, Wall EMC LabsLB67796.000-1008 Paint < 110 ppm

73479 Sampson - Red, Exterior, Door EMC LabsLB67796.000-1009 Paint < 370 ppm

73479 Sampson - Blue, Warehouse, Panel EMC LabsLB67796.000-1010 Paint < 41,700 ppm

73479 Sampson - Gray, Warehouse, Panel EMC LabsLB67796.000-1011 Paint < 34,500 ppm

73499 Sampson - Red, Living Room, Wall EMC LabsLB67796.000-1012 Paint < 140 ppm

73499 Sampson - Teal, NE Bedroom, Wall EMC LabsLB67796.000-1013 Paint 14,900 ppm

73499 Sampson - Green, Living Room, Wall EMC LabsLB67796.000-1014 Paint < 130 ppm

73499 Sampson - White, Kitchen, Wall EMC LabsLB67796.000-1015 Paint 680 ppm

73499 Sampson - Red, Exterior, Wall/Trim EMC LabsLB67796.000-1016 Paint < 190 ppm

73499 Sampson - Brown, Exterior, Wall/Trim EMC LabsLB67796.000-1017 Paint 33,200 ppm

73499 Sampson - White, Pumphouse, Door EMC LabsLB67796.000-1018 Paint 150 ppm

49587 River - Beige, Exterior, Wall/Trim EMC LabsLB67796.000-1019 Paint < 220 ppm

49587 River - White, Exterior, Door/Trim EMC LabsLB67796.000-1020 Paint < 100 ppm

49587 River - White, Interior Shop, Wall EMC LabsLB67796.000-1021 Paint < 130 ppm

49591 River - Blue, Family Room, Wall EMC LabsLB67796.000-1022 Paint < 110 ppm

49591 River - Pink, NE Room, Wall EMC LabsLB67796.000-1023 Paint < 100 ppm

49591 River - White, Interior, Wall EMC LabsLB67796.000-1024 Paint < 110 ppm

49591 River - Green, Exterior, Siding EMC LabsLB67796.000-1025 Paint < 100 ppm

49591 River - White, Exterior, Trim EMC LabsLB67796.000-1026 Paint < 200 ppm

49591 River - Green, Mother-in-Law, Wall EMC LabsLB67796.000-1027 Paint < 320 ppm

49591 River - Blue, Exterior Mother-in-Law, Door EMC LabsLB67796.000-1028 Paint < 1,050 ppm

49591 River - White, Interior Mother-in-Law, Wall EMC LabsLB67796.000-1029 Paint < 110 ppm

49591 River - Gray, Interior Mother-in-Law, Wall EMC LabsLB67796.000-1030 Paint < 100 ppm

49591 River - Beige, Interior Mother-in-Law, Wall EMC LabsLB67796.000-1031 Paint < 100 ppm

2.43

April 2021

Project No.: 67796.000 Phase No.: 0001

Hazardous Materials Survey

CTUIR-FEMA Mitigation Grant Management

Confederated Tribes of the Umatilla Indi

Lead Sample Inventory

Code LocationMaterial Analysis Lab

49683 River - Beige, Bathroom, Wall EMC LabsLB67796.000-1032 Paint 310 ppm

49683 River - White, Interior Main, Wall EMC LabsLB67796.000-1033 Paint < 250 ppm

49683 River - Gray, Laundry Room, Wall EMC LabsLB67796.000-1034 Paint < 430 ppm

49683 River - Off-White, Shop, Door/Trim EMC LabsLB67796.000-1035 Paint < 1,500 ppm

52153 Cayuse - Lt. Purple, W. Bathroom, Wall EMC LabsLB67796.000-1036 Paint < 140 ppm

52153 Cayuse - Off-White, NW Bedroom, Wall EMC LabsLB67796.000-1037 Paint < 300 ppm

52153 Cayuse - Yellow, Family Room, Wall EMC LabsLB67796.000-1038 Paint < 100 ppm

52153 Cayuse - Gray, NE Hall, Wall EMC LabsLB67796.000-1039 Paint < 110 ppm

52153 Cayuse - Lt. Green, E. Bathroom, Wall EMC LabsLB67796.000-1040 Paint < 100 ppm

52153 Cayuse - Beige, NE Interior, Wall EMC LabsLB67796.000-1041 Paint < 190 ppm

52153 Cayuse - Orange, E. Interior, Wall EMC LabsLB67796.000-1042 Paint < 350 ppm

52153 Cayuse - Lt. Blue, SW Living Room, Wall EMC LabsLB67796.000-1043 Paint < 190 ppm

52153 Cayuse - White, Interior Main, Wall EMC LabsLB67796.000-1044 Paint < 140 ppm

52153 Cayuse - Mint Green, Exterior, Paneling EMC LabsLB67796.000-1045 Paint < 130 ppm

52153 Cayuse - Forest Green, Exterior, Trim EMC LabsLB67796.000-1046 Paint < 300 ppm

52153 Cayuse - Gray/Green, Exterior, Panel EMC LabsLB67796.000-1047 Paint < 150 ppm

52153 Cayuse - White, Shop Interior, Wall EMC LabsLB67796.000-1048 Paint < 120 ppm

52277 Cayuse - Lt. Green, Shop, Panel EMC LabsLB67796.000-1049 Paint 19,400 ppm

52277 Cayuse - Orange, Shop Trailer, Wall EMC LabsLB67796.000-1050 Paint 55,600 ppm

52277 Cayuse - Green, Main Exterior, Trim EMC LabsLB67796.000-1051 Paint < 290 ppm

52277 Cayuse - Brown, Main Exterior, Trim EMC LabsLB67796.000-1052 Paint < 370 ppm

53017 Cayuse - White, N. Studio, Wall EMC LabsLB67796.000-1053 Paint < 100 ppm

53017 Cayuse - White, E. Studio, Wall EMC LabsLB67796.000-1054 Paint < 260 ppm

53017 Cayuse - Brown, Ext. Pumphouse, Panel EMC LabsLB67796.000-1055 Paint < 100 ppm

53017 Cayuse - White, Exterior Shop, Door EMC LabsLB67796.000-1056 Paint < 390 ppm

53017 Cayuse - White, Interior Main, Wall EMC LabsLB67796.000-1057 Paint < 250 ppm

2.44

April 2021

Project No.: 67796.000 Phase No.: 0001

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Fibrous GlassNoLAYER 1Shingle, Black/ Gray

None Detected0252734-001 73479 SAMPSON-EXTERIOR ROOF001

20%

QuartzCarbonatesBinder/Filler 80%

Cellulose FiberFibrous Glass

NoLAYER 2Tar, BlackNote: Difficult to separate adjacent layer

None Detected 2%1%

QuartzCarbonatesBinder/Filler 97%

Fibrous GlassNoLAYER 1Shingle, Black/ Gray

None Detected0252734-002 EXTERIOR ROOF

002

20%

QuartzCarbonatesBinder/Filler 80%

Cellulose FiberFibrous Glass

NoLAYER 2Tar, BlackNote: Difficult to separate adjacent layer

None Detected 2%1%

QuartzCarbonatesBinder/Filler 97%

Cellulose FiberNoLAYER 1Siding, Black/ Green

None Detected0252734-003 EXTERIOR, WALLS

003

20%

QuartzCarbonatesBinder/Filler 80%

Cellulose FiberNoLAYER 2Insulation, Tan

None Detected 98%

QuartzGypsum 2%

Cellulose FiberNoLAYER 3Vapor Barrier, Black

None Detected 40%

QuartzBinder/Filler 60%

Page 1 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1Siding, Black/ Green

None Detected0252734-004 EXTERIOR, WALLS

004

20%

QuartzCarbonatesBinder/Filler

80%

Cellulose FiberNoLAYER 2Insulation, Tan

None Detected 98%

QuartzGypsum

2%

Cellulose FiberNoLAYER 3Vapor Barrier, Black

None Detected 40%

QuartzBinder/Filler

60%

YesWindow Caulk, White/ Gray Chrysotile0252734-005 W. EXTERIOR, WINDOW005

3%

CarbonatesQuartzBinder/Filler

97%

Cellulose FiberNoWindow Caulk, White/ Gray None Detected0252734-006 S. EXT. WINDOW

006

1%

CarbonatesQuartzBinder/Filler

99%

Page 2 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1Drywall, Off White/ Brown

None Detected0252734-007 INTERIOR, DINING RM007

12%

GypsumCarbonatesMicaQuartz

88%

Cellulose FiberNoLAYER 2Joint Compound, White/ Off White

None Detected 2%

GypsumMicaQuartzCarbonates

98%

Cellulose FiberNoLAYER 3Popcorn Texture, White/ Off White

None Detected 1%

GypsumMicaQuartzCarbonatesBinder/Filler

99%

Cellulose FiberNoLAYER 1Drywall, Off White/ Brown

None Detected0252734-008 INTERIOR, LIVING RM008

12%

GypsumCarbonatesMicaQuartz

88%

Cellulose FiberNoLAYER 2Popcorn Texture, White/ Off White

None Detected 1%

GypsumMicaQuartzCarbonatesBinder/Filler

99%

Page 3 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1Drywall, Off White/ Brown

None Detected0252734-009 INTERIOR, LIVING RM009

12%

GypsumCarbonatesMicaQuartz

88%

Cellulose FiberNoLAYER 2Joint Compound, White/ Off White

None Detected 1%

GypsumMicaQuartzCarbonates

99%

Cellulose FiberNoLAYER 3Popcorn Texture, White/ Off White

None Detected 1%

GypsumMicaQuartzCarbonatesBinder/Filler

99%

Cellulose FiberNoLAYER 1Drywall, Off White/ Brown

None Detected0252734-010 INTERIOR, N. HALLWAY010

12%

GypsumCarbonatesMicaQuartz

88%

Cellulose FiberNoLAYER 2Popcorn Texture, White/ Off White

None Detected 2%

GypsumMicaQuartzCarbonatesBinder/Filler

98%

Page 4 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1Drywall, Off White/ Brown

None Detected0252734-011 INTERIOR, S. HALLWAY011

12%

GypsumCarbonatesMicaQuartz

88%

Cellulose FiberNoLAYER 2Popcorn Texture, White/ Off White

None Detected 2%

GypsumMicaQuartzCarbonatesBinder/Filler

98%

YesLAYER 112" Floor Tile, Red

Chrysotile0252734-012 KITCHEN

012

3%

CarbonatesQuartzBinder/Filler

97%

Cellulose FiberNoLAYER 2Mastic, Yellow

None Detected 2%

QuartzCarbonatesBinder/Filler

98%

YesLAYER 112" Floor Tile, Red

Chrysotile0252734-013 KITCHEN

013

3%

CarbonatesQuartzBinder/Filler

97%

Cellulose FiberNoLAYER 2Mastic, Yellow

None Detected 1%

QuartzCarbonatesBinder/Filler

99%

Page 5 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoLAYER 1Brick, Red

None Detected0252734-014 WOOD STOVE HEARTH014

QuartzGypsumCarbonates

100%

NoLAYER 2Mortar, Gray

None Detected

QuartzGypsumCarbonatesBinder/Filler

100%

NoLAYER 1Rock, Tan

None Detected0252734-015 LIVING RM

015 QuartzGypsumCarbonates

100%

NoLAYER 2Mortar, Gray

None Detected

QuartzGypsumCarbonatesBinder/Filler

100%

Cellulose FiberNoLAYER 1Drywall, Off White/ Brown

None Detected0252734-016 KITCHEN

016

12%

GypsumCarbonatesMicaQuartz

88%

Cellulose FiberNoLAYER 2Joint Compound, White/ Off White

None Detected 1%

CarbonatesMicaQuartzBinder/Filler

99%

Cellulose FiberYesLAYER 3Texture, White/ Off White

Chrysotile 2% 2%

CarbonatesMicaQuartzBinder/Filler

96%

Page 6 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1Drywall, Off White/ Brown

None Detected0252734-017 SW BEDRM

017

12%

GypsumCarbonatesMicaQuartz

88%

Cellulose FiberYesLAYER 2Joint Compound, White/ Off White

Chrysotile 2% 2%

CarbonatesMicaQuartzBinder/Filler

96%

Cellulose FiberYesLAYER 3Texture, White/ Off White

Chrysotile 2% 2%

CarbonatesMicaQuartzBinder/Filler

96%

Cellulose FiberNoLAYER 1Drywall, Off White/ Brown

None Detected0252734-018 NE BATHRM

018

12%

GypsumCarbonatesMicaQuartz

88%

Cellulose FiberYesLAYER 2Joint Compound, White/ Off White

Chrysotile 3% 1%

CarbonatesMicaQuartzBinder/Filler

96%

Cellulose FiberNoLAYER 1Drywall, Off White/ Brown

None Detected0252734-019 HALLWAY

019

12%

GypsumCarbonatesMicaQuartz

88%

Cellulose FiberNoLAYER 2Joint Compound, White/ Off White

None Detected 1%

CarbonatesMicaQuartzBinder/Filler

99%

Page 7 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1Drywall, Off White/ Brown

None Detected0252734-020 NW BEDRM

020

12%

GypsumCarbonatesMica

88%

YesLAYER 2Texture, White/ Off White

Chrysotile 5%

CarbonatesMicaQuartzBinder/Filler

95%

Cellulose FiberNoLAYER 1Drywall, Off White/ Brown

None Detected0252734-021 E. STORAGE RM

021

12%

GypsumCarbonatesMica

88%

Cellulose FiberYesLAYER 2Joint Compound, White/ Off White

Chrysotile 3% 1%

CarbonatesMicaQuartz

96%

Cellulose FiberNoLAYER 3Texture, White/ Off White

None Detected <1%

CarbonatesMicaQuartzBinder/Filler

99%

Cellulose FiberNoLAYER 1Drywall, Off White/ Brown

None Detected0252734-022 E. STORAGE RM

022

12%

GypsumCarbonatesMica

88%

NoLAYER 2Texture, White/ Off White

None Detected

CarbonatesPerliteMicaQuartzBinder/Filler

100%

Page 8 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoSpray-On Texture, White/ Off White

None Detected0252734-023 E. STORAGE RM

023 CarbonatesPerliteMicaQuartzBinder/Filler

100%

Cellulose FiberSynthetic FiberFibrous Glass

NoLAYER 1Sheet Vinyl, White/ Gray

None Detected0252734-024 MAIN ENTRY

024

15%3%2%

CarbonatesQuartzBinder/Filler

80%

Cellulose FiberSynthetic Fiber

NoLAYER 2Mastic, White/ Gray

None Detected 2%<1%

CarbonatesQuartzBinder/Filler

97%

Cellulose FiberSynthetic FiberFibrous Glass

NoLAYER 1Sheet Vinyl, White/ Gray

None Detected0252734-025 MAIN ENTRY

025

15%3%2%

CarbonatesQuartzBinder/Filler

80%

Cellulose FiberSynthetic FiberFibrous Glass

NoLAYER 2Mastic, White/ Gray

None Detected 3%1%<1%

CarbonatesQuartzBinder/Filler

95%

Page 9 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1Fiberboard, Beige/ Lt. Green

None Detected0252734-026 DINING RM

026

95%

GypsumBinder/Filler

5%

Cellulose FiberYesLAYER 2Texture/ Paint, White/ Off WhiteNote: Difficult to separate adjacent layers

Chrysotile 2% 5%

CarbonatesMicaQuartzBinder/Filler

93%

Fibrous GlassNoLAYER 3Insulation, Gray

None Detected 97%

Carbonates 3%

Cellulose FiberNoLAYER 1Fiberboard, Beige/ Lt. Green

None Detected0252734-027 DINING RM

027

95%

GypsumBinder/Filler

5%

YesLAYER 2Texture/ Paint, White/ Off WhiteNote: Difficult to separate adjacent layers

Chrysotile 3%

CarbonatesMicaQuartzBinder/Filler

97%

Fibrous GlassCellulose Fiber

NoLAYER 3Insulation, Gray

None Detected 95%2%

Carbonates 3%

YesLAYER 112" Floor Tile, Red

Chrysotile0252734-028 NW BEDRM

028

5%

CarbonatesQuartzBinder/Filler

95%

Cellulose FiberNoLAYER 2Mastic, Yellow

None Detected 1%

CarbonatesBinder/Filler

99%

Page 10 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

YesLAYER 112" Floor Tile, Red

Chrysotile0252734-029 NW BEDRM

029

5%

CarbonatesQuartzBinder/Filler

95%

Cellulose FiberNoLAYER 2Mastic, Yellow

None Detected 2%

CarbonatesQuartzBinder/Filler

98%

YesLAYER 112" Floor Tile, White/ Tan

Chrysotile0252734-030 NW BEDRM

030

3%

CarbonatesQuartzBinder/Filler

97%

Cellulose FiberNoLAYER 2Mastic, Yellow

None Detected 1%

CarbonatesQuartzBinder/Filler

99%

YesLAYER 112" Floor Tile, White/ Tan

Chrysotile0252734-031 NW BEDRM

031

3%

CarbonatesQuartzBinder/Filler

97%

Cellulose FiberNoLAYER 2Mastic, Yellow

None Detected 1%

CarbonatesQuartzBinder/Filler

99%

NoLAYER 1Tape, Silver

None Detected0252734-032 INTERIOR, VENT/DUCT032

AluminumCarbonatesBinder/Filler

100%

Cellulose FiberNoLAYER 2Mastic, Clear/ Yellow

None Detected 2%

CarbonatesBinder/Filler

98%

Page 11 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1Mastic, Black

None Detected0252734-033 KITCHEN, WALL

033

<1%

CarbonatesQuartzBinder/Filler

99%

Cellulose FiberYesLAYER 2Texture, White/ Off White

Chrysotile 2% 3%

CarbonatesMicaQuartzBinder/Filler

95%

Cellulose FiberNoLAYER 3Fiber Board, Beige/ Tan

None Detected 95%

CarbonatesBinder/Filler

5%

Cellulose FiberSynthetic Fiber

NoLAYER 1Flooring, Gray/ Tan

None Detected0252734-034 SW BEDRM

034

20%5%

CarbonatesQuartzBinder/Filler

75%

Cellulose FiberSynthetic Fiber

NoLAYER 2Mastic, Brown

None Detected 5%2%

CarbonatesQuartzBinder/Filler

93%

Cellulose FiberSynthetic Fiber

NoLAYER 1Flooring, Brown/ Tan

None Detected0252734-035 SW BEDRM

035

20%5%

CarbonatesQuartzBinder/Filler

75%

Cellulose FiberSynthetic Fiber

NoLAYER 2Mastic, Brown/ Black

None Detected 4%1%

CarbonatesQuartzBinder/Filler

95%

Page 12 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoLAYER 110" Snap Tile, Lt. Gray

None Detected0252734-036 W. HALLWAY

036 CarbonatesQuartzBinder/Filler

100%

Cellulose FiberSynthetic Fiber

NoLAYER 2Mastic, Brown

None Detected 3%1%

CarbonatesQuartzBinder/Filler

96%

Cellulose FiberSynthetic Fiber

NoLAYER 3Vapor Barrier/ Sheet Vinyl, Black/ Lt. Brown

None Detected 25%5%

CarbonatesQuartzBinder/Filler

70%

Cellulose FiberNoLAYER 4Mastic, Brown

None Detected 2%

CarbonatesQuartzBinder/Filler

98%

NoLAYER 110" Snap Tile, Lt. Gray

None Detected0252734-037 W. HALLWAY

037 CarbonatesQuartzBinder/Filler

100%

Cellulose FiberSynthetic Fiber

NoLAYER 2Vapor Barrier/ Sheet Vinyl, Black/ Lt. Brown

None Detected 30%5%

CarbonatesGypsumQuartzBinder/Filler

65%

Cellulose FiberNoLAYER 3Mastic, Brown

None Detected 1%

CarbonatesQuartzBinder/Filler

99%

Page 13 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

YesLAYER 112"x12" VFT, Gray

Chrysotile0252734-038 NW BATHRM

038

3%

CarbonatesQuartzBinder/Filler

97%

Cellulose FiberNoLAYER 2Mastic, Yellow

None Detected 1%

CarbonatesQuartzBinder/Filler

99%

YesLAYER 112"x12" VFT, Gray

Chrysotile0252734-039 NW BATHRM

039

3%

CarbonatesQuartzBinder/Filler

97%

Cellulose FiberNoLAYER 2Mastic, Yellow

None Detected 1%

CarbonatesQuartzBinder/Filler

99%

Cellulose FiberNoLAYER 1Panel, Black/ Tan

None Detected0252734-040 W. BATHRM, TUB

040

85%

GypsumBinder/Filler

15%

Cellulose FiberNoLAYER 2Mastic, Brown

None Detected 3%

CarbonatesQuartzBinder/Filler

97%

NoLAYER 3Caulking, White

None Detected

SiliconeGypsumBinder/Filler

100%

NoCaulk, White None Detected0252734-041 W. BATHRM, TUB

041 SiliconeGypsumBinder/Filler

100%

Page 14 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Synthetic FiberNoLAYER 1Carpet, Lt. Gray

None Detected0252734-042 LIVING RM

042

85%

CarbonatesBinder/Filler

15%

Synthetic FiberNoLAYER 2Mastic, Lt. Gray

None Detected 1%

CarbonatesQuartzBinder/Filler

99%

Cellulose FiberSynthetic Fiber

NoLAYER 3Linoleum, Lt. Brown

None Detected 15%5%

CarbonatesQuartzBinder/Filler

80%

Cellulose FiberNoLAYER 4Mastic/ Leveling Compound, Brown/ Gray

None Detected 5%

CarbonatesQuartzMicaBinder/Filler

95%

Synthetic FiberNoLAYER 1Carpet, Lt. Gray

None Detected0252734-043 LIVING RM

043

85%

CarbonatesBinder/Filler

15%

Synthetic FiberNoLAYER 2Mastic, Lt. Gray

None Detected 1%

CarbonatesQuartzBinder/Filler

99%

Cellulose FiberSynthetic Fiber

NoLAYER 3Linoleum, Lt. Brown

None Detected 15%5%

CarbonatesQuartzBinder/Filler

80%

Cellulose FiberSynthetic Fiber

NoLAYER 4Mastic/ Leveling Compound, Brown/ Gray

None Detected 3%2%

CarbonatesQuartzMicaBinder/Filler

95%

Page 15 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1Fiber Board, Brown

None Detected0252734-044 NE BEDRM

044

95%

CarbonatesBinder/Filler

5%

YesLAYER 2Joint Compound, Off White

Chrysotile 3%

CarbonatesMicaQuartz

97%

Cellulose FiberYesLAYER 3Texture/ Paint, Off White

Chrysotile 2% 2%

CarbonatesMicaQuartzBinder/Filler

96%

NoCaulk, White None Detected0252734-045 E. BATHRM

045 SiliconeCarbonatesBinder/Filler

100%

Fibrous GlassNoLAYER 1Flooring, Brown/ Black

None Detected0252734-046 E. BATHRM

046

10%

CarbonatesQuartzBinder/Filler

90%

Cellulose FiberNoLAYER 2Mastic, Clear

None Detected <1%

CarbonatesQuartzBinder/Filler

99%

Fibrous GlassNoLAYER 3Flooring, Gray

None Detected 10%

CarbonatesQuartzBinder/Filler

90%

Page 16 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Fibrous GlassNoLAYER 1Flooring, Brown/ Black

None Detected0252734-047 E. BATHRM

047

10%

CarbonatesQuartzBinder/Filler

90%

Cellulose FiberNoLAYER 2Mastic, Clear

None Detected <1%

CarbonatesQuartzBinder/Filler

99%

Synthetic FiberNoLAYER 1Carpet, Brown/ Black

None Detected0252734-048 E. BEDRM

048

85%

CarbonatesBinder/Filler

15%

Synthetic FiberNoLAYER 2Mastic, Lt. Gray

None Detected <1%

CarbonatesBinder/Filler

99%

Synthetic FiberNoLAYER 3Foam, Lt. Yellow

None Detected <1%

FoamCarbonatesBinder/Filler

99%

Cellulose FiberFibrous Glass

NoLAYER 1Sheet Vinyl, Off White/ Gray

None Detected0252734-049 E. BEDRM, CLOSET

049

17%3%

CarbonatesQuartzBinder/Filler

80%

Cellulose FiberNoLAYER 2Mastic, Yellow

None Detected 3%

CarbonatesBinder/Filler

97%

Page 17 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberFibrous Glass

NoLAYER 1Sheet Vinyl, Off White/ Gray

None Detected0252734-050 E. BEDRM, CLOSET

050

17%3%

CarbonatesQuartzBinder/Filler

80%

Cellulose FiberNoLAYER 2Mastic, Yellow

None Detected 5%

CarbonatesBinder/Filler

95%

NoGrout, Black None Detected0252734-051 HALLWAY

051 GypsumQuartzCarbonatesMicaBinder/Filler

100%

Cellulose FiberNoLAYER 1Brick, Tan

None Detected0252734-052 WOOD STOVE

052

1%

CarbonatesQuartzMicaBinder/Filler

99%

Cellulose FiberNoLAYER 2Mortar, Off White

None Detected <1%

CarbonatesQuartzBinder/Filler

99%

Fibrous GlassNoLAYER 1Insulation, Pink

None Detected0252734-053 SE SMALL SHED

053

100%

Cellulose FiberNoLAYER 2Vapor Barrier, Black/ Brown

None Detected 70%

GypsumBinder/Filler

30%

Page 18 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Fibrous GlassNoLAYER 1Shingle, Gray/ Black

None Detected0252734-054 SE SMALL SHED

054

15%

CarbonatesQuartzBinder/Filler

85%

NoLAYER 2Roofing Tar, Black

None Detected

GypsumQuartzBinder/Filler

100%

Cellulose FiberNoLAYER 1Shingle, White/ Black

None Detected0252734-055 NE LARGE SHED

055

20%

CarbonatesQuartzBinder/Filler

80%

Cellulose FiberNoLAYER 2Vapor Barrier, Black

None Detected 70%

CarbonatesBinder/Filler

30%

Cellulose FiberSynthetic Fiber

NoVapor Barrier, Black None Detected0252734-056 NE LARGE SHED

056

60%5%

CarbonatesBinder/Filler

35%

Fibrous GlassNoLAYER 1Shingle, White/ Black

None Detected0252734-057 SW LARGE SHED

057

20%

CarbonatesQuartzBinder/Filler

80%

Cellulose FiberNoLAYER 2Tar, Black

None Detected 10%

CarbonatesQuartzBinder/Filler

90%

Page 19 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberYesLAYER 1Sheet Vinyl, Orange

Chrysotile0252734-058 76499 SAMPSON-SE BATHRM058

15% 5%

GypsumCarbonatesQuartzBinder/Filler

80%

Cellulose FiberYesLAYER 2Mastic, BrownNote: Difficult to separate adjacent layer

Chrysotile 2% 2%

CarbonatesGypsumQuartzBinder/Filler

96%

Cellulose FiberYesLAYER 1Sheet Vinyl, Orange

Chrysotile0252734-059 SE BATHRM

059

15% 5%

GypsumCarbonatesQuartzBinder/Filler

80%

Cellulose FiberYesLAYER 2Mastic, BrownNote: Difficult to separate adjacent layer

Chrysotile 2% 2%

CarbonatesGypsumQuartzBinder/Filler

96%

Synthetic FiberNoLAYER 1Carpet, Brown/ Orange

None Detected0252734-060 N. BATHRM

060

85%

CarbonatesBinder/Filler

5%

Cellulose FiberSynthetic Fiber

NoLAYER 2Sheet Vinyl, Gray/ Black

None Detected 15%5%

GypsumQuartzBinder/Filler

80%

Cellulose FiberNoLAYER 3Mastic, Brown

None Detected 1%

CarbonatesQuartzBinder/Filler

99%

Page 20 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Synthetic FiberNoLAYER 1Carpet, Brown/ Orange

None Detected0252734-061 N. BATHRM

061

85%

CarbonatesBinder/Filler

15%

NoLAYER 2Mastic, Lt. Yellow

None Detected

CarbonatesQuartzBinder/Filler

100%

Cellulose FiberSynthetic Fiber

NoLAYER 3Sheet Vinyl, Gray/ Black

None Detected 15%5%

GypsumQuartzBinder/Filler

80%

Cellulose FiberSynthetic Fiber

NoLAYER 4Mastic, Brown

None Detected 1%<1%

CarbonatesQuartzBinder/Filler

98%

Synthetic FiberNoLAYER 1Carpet, Orange

None Detected0252734-062 NE BEDRM

062

85%

CarbonatesBinder/Filler

15%

Cellulose FiberSynthetic Fiber

NoLAYER 212"x12" VFT, White

None Detected 15%5%

GypsumQuartzBinder/Filler

80%

Cellulose FiberSynthetic Fiber

NoLAYER 3Mastic, Brown

None Detected 2%1%

CarbonatesQuartzBinder/Filler

97%

Page 21 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Synthetic FiberNoLAYER 1Carpet, Orange

None Detected0252734-063 NE BEDRM

063

85%

CarbonatesBinder/Filler

15%

Synthetic FiberNoLAYER 2Mastic, Yellow

None Detected 2%

CarbonatesBinder/Filler

98%

Cellulose FiberSynthetic Fiber

NoLAYER 312"x12" VFT, White

None Detected 15%5%

GypsumQuartzBinder/Filler

80%

Cellulose FiberSynthetic Fiber

NoLAYER 4Mastic, Brown

None Detected 3%1%

CarbonatesQuartzBinder/Filler

96%

Synthetic FiberNoLAYER 1Carpet, Purple

None Detected0252734-064 NW BEDRM

064

85%

CarbonatesBinder/Filler

15%

Cellulose FiberSynthetic Fiber

NoLAYER 2Sheet Vinyl, Blue/ Black

None Detected 15%5%

GypsumQuartzBinder/Filler

80%

Cellulose FiberSynthetic Fiber

NoLAYER 3Mastic, Brown

None Detected 1%<1%

CarbonatesQuartzBinder/Filler

98%

Page 22 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Synthetic FiberNoLAYER 1Carpet, Purple

None Detected0252734-065 NW BEDRM

065

85%

CarbonatesBinder/Filler

15%

Cellulose FiberSynthetic Fiber

NoLAYER 2Sheet Vinyl, Blue/ Black

None Detected 15%5%

CarbonatesQuartzBinder/Filler

80%

Cellulose FiberNoLAYER 3Mastic, Black

None Detected 1%

CarbonatesBinder/Filler

99%

Cellulose FiberSynthetic Fiber

NoLAYER 19"x9" VAT, Gray/ Black

None Detected0252734-066 N. HALL

066

15%5%

CarbonatesQuartzBinder/Filler

80%

Cellulose FiberSynthetic Fiber

NoLAYER 2Mastic, Brown

None Detected 3%1%

CarbonatesQuartzBinder/Filler

96%

Cellulose FiberSynthetic Fiber

NoLAYER 3Vapor Barrier, Black

None Detected 60%5%

CarbonatesBinder/Filler

35%

Cellulose FiberSynthetic Fiber

NoLAYER 4Mastic, Brown

None Detected 3%1%

CarbonatesBinder/Filler

96%

Page 23 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberSynthetic Fiber

NoLAYER 19"x9" VAT, Gray/ Black

None Detected0252734-067 N. HALL

067

15%5%

CarbonatesQuartzBinder/Filler

80%

Cellulose FiberNoLAYER 2Mastic, Brown

None Detected <1%

CarbonatesBinder/Filler

99%

Cellulose FiberSynthetic Fiber

NoLAYER 3Vapor Barrier, Black

None Detected 60%5%

CarbonatesBinder/Filler

35%

NoRock, BeigeNote: No Mortar Present

None Detected0252734-068 WOOD STOVE

068 GypsumQuartzPerliteBinder/Filler

100%

Page 24 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberFibrous Glass

NoLAYER 1Sheet Vinyl, Gray

None Detected0252734-069 KITCHEN

069

17%3%

CarbonatesQuartzBinder/Filler

80%

Cellulose FiberNoLAYER 2Mastic, Yellow

None Detected 3%

CarbonatesBinder/Filler

97%

Cellulose FiberFibrous Glass

NoLAYER 3Sheet Vinyl, Off White

None Detected 17%3%

CarbonatesQuartzBinder/Filler

80%

Cellulose FiberNoLAYER 4Mastic, Yellow

None Detected 2%

CarbonatesQuartzBinder/Filler

98%

Please see EMC Labs Sample Number 0252734-182 for Additional Asbestos Containing Layer(s)

Page 25 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberFibrous Glass

NoLAYER 1Sheet Vinyl, Gray

None Detected0252734-070 KITCHEN

070

17%3%

CarbonatesQuartzBinder/Filler

80%

NoLAYER 2Mastic, Yellow

None Detected

CarbonatesQuartzBinder/Filler

100%

Cellulose FiberFibrous Glass

NoLAYER 3Sheet Vinyl, Off White

None Detected 17%3%

CarbonatesQuartzBinder/Filler

80%

Cellulose FiberNoLAYER 4Mastic, Yellow

None Detected 1%

CarbonatesBinder/Filler

99%

Please see EMC Labs Sample Number 0252734-182 for Additional Asbestos Containing Layer(s)

Synthetic FiberNoLAYER 1Carpet, Green

None Detected0252734-071 N. FOYER

071

95%

CarbonatesBinder/Filler

5%

Synthetic FiberNoLAYER 2Mastic, Lt. Gray

None Detected <1%

CarbonatesBinder/Filler

99%

NoLAYER 3Foam, Gray

None Detected

FoamBinder/Filler

100%

Cellulose FiberNoGypsum Board, White/ BrownNote: No Joint Compound Present

None Detected0252734-072 S. KITCHEN

072

12%

GypsumCarbonatesMica

88%

Page 26 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1Gypsum Board, White/ Brown

None Detected0252734-073 N. HALL

073

12%

GypsumCarbonatesMica

88%

Cellulose FiberYesLAYER 2Joint Compound, Off White

Chrysotile 2% 1%

CarbonatesMicaQuartz

97%

Cellulose FiberNoLAYER 1Gypsum Board, White/ Brown

None Detected0252734-074 N. HALL

074

12%

GypsumCarbonatesMica

88%

YesLAYER 2Joint Compound, Off White

Chrysotile 2%

CarbonatesMicaQuartz

98%

Cellulose FiberNoLAYER 1Gypsum Board, White/ Brown

None Detected0252734-075 N. DINING RM

075

12%

GypsumCarbonatesMica

88%

Cellulose FiberYesLAYER 2Joint Compound, Off White

Chrysotile 3% 1%

CarbonatesMicaQuartz

96%

Cellulose FiberNoGypsum Board, White/ BrownNote: No Joint Compound or Texture Present

None Detected0252734-076 W. LIVING RM

076

12%

GypsumCarbonatesMica

88%

Page 27 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1Gypsum Board, White/ Brown

None Detected0252734-077 W. LIVING RM

077

12%

GypsumCarbonatesMica

88%

Cellulose FiberNoLAYER 2Joint Compound, Off White

None Detected <1%

CarbonatesMicaBinder/Filler

99%

Cellulose FiberNoLAYER 1Gypsum Board, White/ Brown

None Detected0252734-078 NE BEDRM

078

12%

GypsumCarbonatesMica

88%

Cellulose FiberYesLAYER 2Joint Compound, Off White

Chrysotile 3% 1%

CarbonatesMicaQuartz

96%

Cellulose FiberNoLAYER 1Laminate Counter, Beige/ Brown

None Detected0252734-079 KITCHEN, LAMINATE COUNTER

079

95%

GypsumBinder/Filler

5%

Cellulose FiberNoLAYER 2Mastic, Yellow

None Detected 1%

CarbonatesBinder/Filler

99%

Page 28 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoLAYER 1Brick, Off White

None Detected0252734-080 DINING RM, STOVE

080 QuartzMicaGypsumBinder/Filler

100%

NoLAYER 2Mastic, Lt. Gray

None Detected

GypsumQuartzBinder/Filler

100%

Cellulose FiberNoLAYER 3Fiberboard, Gray

None Detected 95%

CarbonatesBinder/Filler

5%

Synthetic FiberNoLAYER 1Carpet, Lime

None Detected0252734-081 NE BEDRM

081

95%

CarbonatesBinder/Filler

5%

Synthetic FiberNoLAYER 2Mastic, Yellow

None Detected 1%

CarbonatesBinder/Filler

99%

Cellulose FiberSynthetic Fiber

NoLAYER 3VAT, Green/ Black

None Detected 15%5%

CarbonatesQuartzBinder/Filler

80%

Cellulose FiberNoLAYER 4Mastic, Brown

None Detected <1%

CarbonatesQuartzBinder/Filler

99%

Page 29 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Synthetic FiberNoLAYER 1Carpet, Lime

None Detected0252734-082 NE BEDRM

082

95%

CarbonatesBinder/Filler

5%

Synthetic FiberNoLAYER 2Mastic, Yellow

None Detected 1%

CarbonatesBinder/Filler

99%

Cellulose FiberSynthetic Fiber

NoLAYER 3VAT, Green/ Black

None Detected 15%5%

CarbonatesQuartzBinder/Filler

80%

Cellulose FiberNoLAYER 4Mastic, Brown

None Detected <1%

CarbonatesQuartzBinder/Filler

99%

YesSink Undercoating, Gray Chrysotile0252734-083 KITCHEN

083

10%

CarbonatesQuartzBinder/Filler

90%

Cellulose FiberNoLAYER 1Wall Panel, Brown/ Tan

None Detected0252734-084 NE BATHRM, TUB WALL084

95%

CarbonatesBinder/Filler

5%

NoLAYER 2Mastic, Yellow

None Detected

CarbonatesQuartzBinder/Filler

100%

Page 30 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1Tape, Silver

None Detected0252734-085 N. HALL, DUCT

085

5%

AluminumCarbonatesBinder/Filler

95%

Cellulose FiberNoLAYER 2Mastic, Clear

None Detected 1%

CarbonatesQuartzBinder/Filler

99%

WollastoniteNoLAYER 1Ceramic Tile, White

None Detected0252734-086 SE SHOWER

086

3%

GypsumQuartzBinder/Filler

97%

NoLAYER 2Grout, White

None Detected

CarbonatesQuartzBinder/Filler

100%

NoLAYER 3Mastic, Cream

None Detected

CarbonatesQuartzBinder/Filler

100%

Cellulose FiberFibrous Glass

NoLAYER 1Sheet Vinyl, White

None Detected0252734-087 NE BEDRM, CLOSET087

15%5%

CarbonatesQuartzPerliteBinder/Filler

80%

Cellulose FiberNoLAYER 2Mastic, Lt. Yellow

None Detected 3%

GypsumQuartzBinder/Filler

97%

Page 31 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1Sheet Vinyl, White

None Detected0252734-088 NE BEDRM, CLOSET088

15%

CarbonatesGypsumQuartzBinder/Filler

85%

Cellulose FiberNoLAYER 2Mastic, Lt. Yellow

None Detected 3%

QuartzCarbonatesBinder/Filler

97%

NoWindow Frame Caulk, White None Detected0252734-089 EXTERIOR, WINDOW089

CarbonatesQuartzBinder/Filler

100%

Fibrous GlassNoLAYER 1Shingle, Green/ Black

None Detected0252734-090 EXT. ROOF

090

15%

QuartzCarbonatesBinder/Filler

85%

Fibrous GlassNoLAYER 2Shingle, Green/ Black

None Detected 15%

QuartzCarbonatesBinder/Filler

85%

Page 32 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Fibrous GlassNoLAYER 1Shingle, Green/ Black

None Detected0252734-091 EXT. ROOF

091

15%

QuartzCarbonatesBinder/Filler

85%

Fibrous GlassNoLAYER 2Shingle, Green/ Black

None Detected 15%

QuartzCarbonatesBinder/Filler

85%

Cellulose FiberNoLAYER 3Felt, Black

None Detected 45%

CarbonatesBinder/Filler

55%

Fibrous GlassCellulose Fiber

NoLAYER 1Insulation, Yellow

None Detected0252734-092 PUMP HOUSE

092

95%2%

CarbonatesBinder/Filler

3%

Cellulose FiberFibrous Glass

NoLAYER 2Insulation Tape, Silver

None Detected 40%10%

AluminumCarbonatesQuartzBinder/Filler

50%

Fibrous GlassCellulose Fiber

NoLAYER 1Insulation, Yellow

None Detected0252734-093 PUMP HOUSE

093

95%3%

CarbonatesBinder/Filler

2%

Cellulose FiberFibrous Glass

NoLAYER 2Vapor Barrier, Black/ Brown

None Detected 40%15%

GypsumBinder/Filler

45%

NoCaulking, White/ Gray None Detected0252734-094 GREEN HOUSE, EXT WINDOW094

CarbonatesQuartzBinder/Filler

100%

Page 33 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Fibrous GlassNoLAYER 1Insulation, Yellow

None Detected0252734-095 SHOP/ANNEX

095

98%

GypsumBinder/Filler

2%

Cellulose FiberFibrous Glass

NoLAYER 2Vapor Barrier, Black/ Tan

None Detected 40%5%

GypsumBinder/Filler

55%

Cellulose FiberNoLAYER 1Drywall, Off White/ Brown

None Detected0252734-096 SHOP/ANNEX

096

12%

GypsumCarbonatesMicaCarbonates

88%

Cellulose FiberNoLAYER 2Texture, White/ Off White

None Detected 1%

CarbonatesPerliteQuartzBinder/Filler

99%

Cellulose FiberNoLAYER 1Drywall, Off White/ Brown

None Detected0252734-097 SHOP/ANNEX

097

12%

GypsumCarbonatesMicaCarbonates

88%

Cellulose FiberNoLAYER 2Texture, White/ Off White

None Detected <1%

CarbonatesPerliteQuartzBinder/Filler

99%

Page 34 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Fibrous GlassNoLAYER 1Insulation, Yellow

None Detected0252734-098 SHOP/ANNEX

098

98%

GypsumBinder/Filler

2%

Cellulose FiberFibrous Glass

NoLAYER 2Vapor Barrier, Black/ Tan

None Detected 40%5%

GypsumBinder/Filler

55%

NoLAYER 1Ceramic Tile, White/ Red

None Detected0252734-099 SHOP/ANNEX

099 QuartzGypsumCarbonatesBinder/Filler

100%

Cellulose FiberNoLAYER 2Grout, Beige/ Gray

None Detected <1%

QuartzGypsumCarbonatesBinder/Filler

99%

NoLAYER 1Ceramic Tile, White/ Red

None Detected0252734-100 SHOP/ANNEX

100 QuartzGypsumCarbonatesBinder/Filler

100%

Cellulose FiberNoLAYER 2Grout, Beige/ Gray

None Detected <1%

QuartzGypsumCarbonatesBinder/Filler

99%

Cellulose FiberNoLAYER 3Mastic, White/ Yellow

None Detected 1%

CarbonatesQuartzBinder/Filler

99%

Page 35 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoInsulation, Silver None Detected0252734-101 49587 RIVER-N. INTERIOR101

AluminumGypsumBinder/Filler

100%

NoLAYER 1Ceramic Tile, Gray

None Detected0252734-102 E. SHOWER WALL

102 QuartzGypsumBinder/Filler

100%

NoLAYER 2Grout, Gray

None Detected

QuartzGypsumCarbonatesBinder/Filler

100%

NoPlaster, Lt. Gray None Detected0252734-103 E. SHOWER WALL

103 GypsumPerliteQuartzCarbonatesBinder/Filler

100%

NoPlaster, Lt. Gray None Detected0252734-104 E. SHOWER WALL

104 GypsumPerliteQuartzCarbonatesBinder/Filler

100%

Page 36 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoLAYER 1Ceramic Tile, Gray

None Detected0252734-105 E. SHOWER FLOOR

105 QuartzGypsumBinder/Filler

100%

NoLAYER 2Grout, Gray

None Detected

GypsumQuartzCarbonatesBinder/Filler

100%

NoFoam, White/ Yellow None Detected0252734-106 INT. WALLS

106 FoamBinder/Filler

100%

Cellulose FiberNoVapor Barrier, Black None Detected0252734-107 INT. WINDOW FRAMES107

3%

QuartzCarbonatesBinder/Filler

97%

NoLAYER 1Brick, Tan

None Detected0252734-108 FIREPLACE

108 QuartzGypsumBinder/Filler

100%

NoLAYER 2Mortar, Gray

None Detected

GypsumQuartzCarbonatesBinder/Filler

100%

Page 37 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoLAYER 1Ceramic Tile, Gray

None Detected0252734-109 W. SHOWER

109 QuartzGypsumBinder/Filler

100%

NoLAYER 2Grout, Gray

None Detected

GypsumQuartzCarbonatesBinder/Filler

100%

NoLAYER 1Tape, Silver

None Detected0252734-110 CEILING

110 AluminumGypsumBinder/Filler

100%

Cellulose FiberNoLAYER 2Mastic, Yellow

None Detected 1%

QuartzCarbonatesBinder/Filler

99%

Fibrous GlassNoLAYER 1Insulation, Yellow

None Detected0252734-111 INT. WALLS

111

98%

GypsumBinder/Filler

2%

Cellulose FiberFibrous Glass

NoLAYER 2Wrap, White/ Silver

None Detected 40%5%

AluminumCarbonatesBinder/Filler

55%

Fibrous GlassNoLAYER 1Insulation, Pink

None Detected0252734-112 INT. WALLS

112

98%

GypsumBinder/Filler

2%

Cellulose FiberFibrous Glass

NoLAYER 2Wrap, Black

None Detected 5%2%

CarbonatesBinder/Filler

93%

Page 38 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoLAYER 1Ceramic Tile, Gray/ Beige

None Detected0252734-113 W. SHOWER

113 QuartzGypsumBinder/Filler

100%

NoLAYER 2Grout, Gray

None Detected

QuartzGypsumCarbonatesBinder/Filler

100%

Cellulose FiberNoFiberboard, White/ Gray None Detected0252734-114 W. SHOWER

114

65%

GypsumCarbonatesQuartzBinder/Filler

35%

Cellulose FiberNoPlaster, White/ Gray None Detected0252734-115 W. SHOWER

115

<1%

GypsumPerliteQuartzCarbonatesBinder/Filler

99%

Cellulose FiberNoCaulking, Clear None Detected0252734-116 MAIN EXTERIOR, WINDOW FRAME116

1%

CarbonatesGypsumBinder/Filler

99%

Page 39 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1Millboard, Gray

None Detected0252734-117 MAIN EXTERIOR

117

65%

GypsumQuartzCarbonatesBinder/Filler

35%

NoLAYER 2Vapor Barrier, Gray

None Detected

CarbonatesGypsumBinder/Filler

100%

Fibrous GlassNoLAYER 1Shingle, Black/ Gray

None Detected0252734-118 MAIN ROOF

118

20%

QuartzCarbonatesBinder/Filler

80%

Cellulose FiberNoLAYER 2Vapor Barrier, Black

None Detected 5%

CarbonatesBinder/Filler

95%

Fibrous GlassNoLAYER 1Shingle, Black/ Gray

None Detected0252734-119 MAIN ROOF

119

20%

QuartzCarbonatesBinder/Filler

80%

Cellulose FiberNoLAYER 2Vapor Barrier, Black

None Detected 5%

CarbonatesBinder/Filler

95%

Cellulose FiberNoLAYER 1Millboard, Gray

None Detected0252734-120 MAIN EXTERIOR

120

65%

GypsumQuartzCarbonatesBinder/Filler

35%

NoLAYER 2Vapor Barrier, Gray

None Detected

CarbonatesGypsumBinder/Filler

100%

Page 40 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1Shingle, Black/ Gray

None Detected0252734-121 PUMP HOUSE

121

20%

QuartzCarbonatesBinder/Filler

80%

Cellulose FiberNoLAYER 2Tabletop, Black

None Detected 10%

QuartzCarbonatesBinder/Filler

90%

Cellulose FiberNoLAYER 3Vapor Barrier, Black

None Detected 40%

QuartzCarbonatesBinder/Filler

60%

NoLAYER 1Wall Insulation, Green

None Detected0252734-122 PUMP HOUSE

122 CarbonatesBinder/Filler

100%

Fibrous GlassNoLAYER 2Wrap, Silver

None Detected 5%

AluminumCarbonatesBinder/Filler

95%

Fibrous GlassNoLAYER 1Insulation, Pink

None Detected0252734-123 SHOP

123

98%

GypsumBinder/Filler

2%

Cellulose FiberFibrous Glass

NoLAYER 2Vapor Barrier, White/ Off White

None Detected 5%3%

CarbonatesGypsumBinder/Filler

92%

Page 41 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1Drywall, Off White/ Brown

None Detected0252734-124 SHOP

124

12%

GypsumCarbonatesMicaQuartz

88%

Cellulose FiberNoLAYER 2Joint Compound, White/ Off White

None Detected 2%

CarbonatesPerliteQuartzBinder/Filler

98%

NoLAYER 3Texture, White/ Off White

None Detected

CarbonatesPerliteQuartzBinder/Filler

100%

Cellulose FiberNoLAYER 1Drywall, Off White/ Brown

None Detected0252734-125 SHOP

125

12%

GypsumCarbonatesMicaQuartz

88%

Cellulose FiberNoLAYER 2Joint Compound, White/ Off White

None Detected 2%

CarbonatesPerliteQuartzBinder/Filler

98%

NoLAYER 3Texture, White/ Off White

None Detected

CarbonatesPerliteQuartzBinder/Filler

100%

Page 42 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1Drywall, Off White/ Brown

None Detected0252734-126 SHOP

126

12%

GypsumCarbonatesMicaQuartz

88%

Cellulose FiberNoLAYER 2Joint Compound, White/ Off White

None Detected 1%

CarbonatesPerliteQuartzBinder/Filler

99%

NoLAYER 3Texture, White/ Off White

None Detected

CarbonatesPerliteQuartzBinder/Filler

100%

NoLAYER 1Ceramic Grout, Gray

None Detected0252734-127 49591 RIVER-W. LAUNDRY RM127

GypsumQuartzCarbonatesBinder/Filler

100%

Cellulose FiberNoLAYER 2Mastic, Beige/ Lt. Yellow

None Detected 1%

CarbonatesQuartzBinder/Filler

99%

Page 43 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoLAYER 1Ceramic Tile, Lt. Gray/ Gray

None Detected0252734-128 W. LAUNDRY RM

128 GypsumQuartzBinder/Filler

100%

NoLAYER 2Grout, Gray

None Detected

QuartzGypsumCarbonatesBinder/Filler

100%

Cellulose FiberNoLAYER 3Plaster, Off White

None Detected <1%

GypsumQuartzCarbonatesBinder/Filler

99%

NoLAYER 1Brick, Red

None Detected0252734-129 S. FAMILY RM, FIREPLACE129

QuartzGypsumBinder/Filler

100%

NoLAYER 2Mortar, Brown

None Detected

GypsumQuartzCarbonatesBinder/Filler

100%

NoLAYER 1Brick, Red

None Detected0252734-130 S. FAMILY RM, FIREPLACE130

QuartzGypsumBinder/Filler

100%

NoLAYER 2Mortar, Gray

None Detected

GypsumQuartzCarbonatesBinder/Filler

100%

Page 44 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 19" VAT, Beige

None Detected0252734-131 SW RM

131

10%

GypsumCarbonatesQuartzBinder/Filler

90%

Cellulose FiberSynthetic Fiber

NoLAYER 2Vapor Barrier, Black

None Detected 60%5%

GypsumBinder/Filler

35%

Cellulose FiberNoLAYER 3Mastic, Brown

None Detected 2%

GypsumQuartzBinder/Filler

98%

TalcYesWall Texture/ Paint, Beige Chrysotile0252734-132 HALL, E. KITCHEN

132

3% 1%

CarbonatesMicaQuartzGypsumBinder/Filler

96%

NoLAYER 112" Ceramic Tile, White/ Lt. Gray

None Detected0252734-133 LIVING RM

133 GypsumQuartzBinder/Filler

100%

NoLAYER 2Grout, Gray

None Detected

QuartzGypsumCarbonatesBinder/Filler

100%

NoLAYER 3Cement, Lt. Gray

None Detected

CarbonatesQuartzGypsumBinder/Filler

100%

Page 45 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoLAYER 12" Ceramic Tile, Blue/ Lt. Gray

None Detected0252734-134 W. FOYER

134 GypsumQuartzBinder/Filler

100%

NoLAYER 2Grout, Gray

None Detected

CarbonatesQuartzGypsumBinder/Filler

100%

NoLAYER 3Mastic, Beige

None Detected

CarbonatesQuartzBinder/Filler

100%

NoLAYER 12" Ceramic Tile, Blue/ Lt. Gray

None Detected0252734-135 LAUNDRY RM

135 GypsumQuartzBinder/Filler

100%

NoLAYER 2Grout, Gray

None Detected

CarbonatesQuartzGypsumBinder/Filler

100%

NoLAYER 3Mastic, Beige

None Detected

CarbonatesQuartzBinder/Filler

100%

NoLAYER 112" Ceramic Tile, Gray/ RedNote: No Grout Present

None Detected0252734-136 W. FOYER

136 GypsumQuartzBinder/Filler

100%

NoLAYER 2Mastic, Beige

None Detected

CarbonatesQuartzBinder/Filler

100%

Page 46 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoLAYER 112" Ceramic Tile, Gray/ RedNote: No Grout Present

None Detected0252734-137 W. FOYER

137 GypsumQuartzBinder/Filler

100%

NoLAYER 2Mastic, Beige

None Detected

CarbonatesQuartzBinder/Filler

100%

Cellulose FiberNoLAYER 1Gypsum Board, White/ Brown

None Detected0252734-138 S. FAMILY RM

138

12%

GypsumCarbonatesQuartzMica

88%

NoLAYER 2Joint Compound, Off White

None Detected

CarbonatesMicaPerliteQuartzBinder/Filler

100%

NoLAYER 3Texture/ Paint, Off White/ White

None Detected

CarbonatesMicaQuartzBinder/Filler

100%

Page 47 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1Gypsum Board, White/ Brown

None Detected0252734-139 N. HALL, N. FAMILY RM139

12%

GypsumCarbonatesQuartzMica

88%

NoLAYER 2Joint Compound, Off White/ White

None Detected

CarbonatesMicaPerliteQuartzBinder/Filler

100%

Cellulose FiberNoLAYER 1Gypsum Board, White/ Brown

None Detected0252734-140 W. KITCHEN

140

12%

GypsumCarbonatesQuartzMica

88%

NoLAYER 2Joint Compound, Off White/ White

None Detected

CarbonatesMicaPerliteQuartzBinder/Filler

100%

Cellulose FiberNoLAYER 1Gypsum Board, White/ Brown

None Detected0252734-141 S. BATHRM

141

12%

GypsumCarbonatesQuartzMica

88%

NoLAYER 2Joint Compound, Off White/ White

None Detected

CarbonatesMicaPerliteQuartzBinder/Filler

100%

Page 48 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1Gypsum Board, White/ Brown

None Detected0252734-142 N. BATHRM, HALL

142

12%

GypsumCarbonatesQuartzMica

88%

NoLAYER 2Joint Compound, Off White

None Detected

GypsumMicaQuartzBinder/Filler

100%

Cellulose FiberNoVapor Barrier Paper, Black/ Brown None Detected0252734-143 NE RM

143

65%

GypsumBinder/Filler

35%

Cellulose FiberNoFloor Mastic, Cream None Detected0252734-144 S. FAMILY RM

144

2%

CarbonatesQuartzBinder/Filler

98%

NoLAYER 19" VAT, Beige

None Detected0252734-145 SW RM

145 CarbonatesGypsumQuartzBinder/Filler

100%

Cellulose FiberSynthetic Fiber

NoLAYER 2Vapor Barrier, Black

None Detected 45%5%

GypsumBinder/Filler

50%

Cellulose FiberNoLAYER 3Mastic, Brown

None Detected <1%

GypsumCarbonatesQuartzBinder/Filler

99%

Page 49 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoCeramic Tile Grout, Gray None Detected0252734-146 NE RM

146 QuartzGypsumCarbonatesBinder/Filler

100%

NoLAYER 1Ceramic Tile, White/ Off White

None Detected0252734-147 S. BATHRM, WALL

147 GypsumQuartzBinder/Filler

100%

NoLAYER 2Grout, Gray

None Detected

CarbonatesGypsumQuartzBinder/Filler

100%

NoLAYER 3Mastic, Cream

None Detected

GypsumQuartzCarbonatesBinder/Filler

100%

NoLAYER 1Brick, Red

None Detected0252734-148 N. LIVING RM, WOOD STOVE148

GypsumQuartzBinder/Filler

100%

NoLAYER 2Mortar, Gray

None Detected

CarbonatesGypsumQuartzBinder/Filler

100%

Page 50 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1Wall Insulation, Brown

None Detected0252734-149 SE RM, E. WALL

149

95%

GypsumQuartz

5%

Cellulose FiberNoLAYER 2Vapor Barrier, Silver/ Black

None Detected 40%

AluminumGypsumQuartzBinder/Filler

60%

Fibrous GlassNoWall Insulation, Pink None Detected0252734-150 S. BATHRM

150

98%

Gypsum 2%

Cellulose FiberNoLAYER 1Wall Insulation, Brown

None Detected0252734-151 S., RM, S. WALL

151

95%

GypsumQuartz

5%

Cellulose FiberNoLAYER 2Vapor Barrier, Silver/ Black

None Detected 40%

AluminumGypsumQuartzBinder/Filler

60%

Cellulose FiberNoDot Mastic, Yellow/ Tan None Detected0252734-152 LIVING RM, N. WALL

152

1%

CarbonatesGypsumQuartzBinder/Filler

99%

Cellulose FiberNoDot Mastic, Yellow/ Tan None Detected0252734-153 LIVING RM, N. WALL

153

<1%

CarbonatesQuartzBinder/Filler

99%

Cellulose FiberNoVapor Barrier, Black None Detected0252734-154 S. HALL, FLOOR

154

65%

GypsumBinder/Filler

35%

Page 51 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoVapor Barrier, Black None Detected0252734-155 SE RM, FLOOR

155

65%

GypsumBinder/Filler

35%

Cellulose FiberNoRock Wall Grout, Gray None Detected0252734-156 MAIN EXTERIOR

156

<1%

GypsumQuartzCarbonatesBinder/Filler

99%

NoDoor Frame Caulk, Green/ Clear None Detected0252734-157 MAIN EXTERIOR

157 CarbonatesSiliconeBinder/Filler

100%

NoDoor Frame Caulk, Green/ White None Detected0252734-158 MAIN EXTERIOR

158 CarbonatesGypsumBinder/Filler

100%

Fibrous GlassNoShingle/ Tar, Black None Detected0252734-159 MAIN, ROOF

159

20%

CarbonatesQuartzBinder/Filler

80%

Fibrous GlassNoShingle/ Tar, Black None Detected0252734-160 MAIN, ROOF

160

20%

CarbonatesQuartzBinder/Filler

80%

Page 52 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoLAYER 1Ceramic Tile, Dk. Brown/ Gray

None Detected0252734-161 MOTHER-IN-LAW, WOOD STOVE161

GypsumQuartzBinder/Filler

100%

Cellulose FiberNoLAYER 2Cement, Off White

None Detected <1%

CarbonatesQuartzGypsumBinder/Filler

99%

NoLAYER 1Ceramic Tile, Lt. Green/ Gray

None Detected0252734-162 MOTHER-IN-LAW, SHOWER162

GypsumQuartzBinder/Filler

100%

Cellulose FiberNoLAYER 2Cement, Off White

None Detected <1%

CarbonatesQuartzGypsumBinder/Filler

99%

NoLAYER 1Ceramic Tile, Lt. Green/ Gray

None Detected0252734-163 MOTHER-IN-LAW

163 GypsumQuartzBinder/Filler

100%

Cellulose FiberNoLAYER 2Grout, Lt. Gray

None Detected <1%

GypsumQuartzCarbonatesBinder/Filler

99%

NoLAYER 3Cement, Off White

None Detected

CarbonatesBinder/Filler

100%

Page 53 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1Drywall, Off White/ Brown

None Detected0252734-164 MOTHER-IN-LAW

164

12%

GypsumCarbonatesMicaQuartz

88%

NoLAYER 2Joint Compound, White/ Off White

None Detected

CarbonatesPerliteQuartzBinder/Filler

100%

Cellulose FiberNoLAYER 1Drywall, Off White/ Brown

None Detected0252734-165 MOTHER-IN-LAW

165

12%

GypsumCarbonatesMicaQuartz

88%

NoLAYER 2Joint Compound, White/ Off White

None Detected

CarbonatesMicaQuartzBinder/Filler

100%

Cellulose FiberNoLAYER 1Drywall, Off White/ Brown

None Detected0252734-166 MOTHER-IN-LAW

166

12%

GypsumCarbonatesMicaQuartz

88%

NoLAYER 2Joint Compound, White/ Off White

None Detected

CarbonatesMicaQuartzBinder/Filler

100%

Page 54 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Fibrous GlassNoLAYER 1Insulation, Yellow

None Detected0252734-167 MOTHER-IN-LAW

167

98%

Carbonates 2%

Cellulose FiberNoLAYER 2Vapor Barrier, Black

None Detected 70%

CarbonatesBinder/Filler

30%

NoLAYER 114" Ceramic Tile, Tan

None Detected0252734-168 MOTHER-IN-LAW

168 GypsumQuartzCarbonatesBinder/Filler

100%

NoLAYER 2Grout, Dk. Gray

None Detected

CarbonatesQuartzGypsumMicaBinder/Filler

100%

Cellulose FiberNoLAYER 3Mastic, Brown

None Detected 1%

CarbonatesQuartzBinder/Filler

99%

Cellulose FiberNoLAYER 1Fiber Board, Off White

None Detected0252734-169 MOTHER-IN-LAW

169

60%

CarbonatesQuartzBinder/Filler

40%

NoLAYER 2Joint Compound, White

None Detected

CarbonatesMicaQuartzBinder/Filler

100%

Page 55 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoLAYER 1Ceramic Tile, Beige

None Detected0252734-170 MOTHER-IN-LAW

170 GypsumQuartzCarbonatesBinder/Filler

100%

Cellulose FiberNoLAYER 2Fiber Board, Off White

None Detected 60%

CarbonatesQuartzBinder/Filler

40%

NoLAYER 3Joint Compound, White

None Detected

CarbonatesMicaQuartzBinder/Filler

100%

NoExterior Window Caulk, White None Detected0252734-171 MOTHER-IN-LAW, EXTER.171

CarbonatesQuartzBinder/Filler

100%

Fibrous GlassNoLAYER 1Wall Insulation, White

None Detected0252734-172 MOTHER-IN-LAW, GARAGE172

98%

Carbonates 2%

Cellulose FiberNoLAYER 2Vapor Barrier, Black/ Brown

None Detected 70%

CarbonatesBinder/Filler

30%

Fibrous GlassNoRoof Shingle/ Tar, Black None Detected0252734-173 SE SHED

173

15%

CarbonatesQuartzBinder/Filler

85%

Page 56 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoGrout, Gray None Detected0252734-174 SE SHED, WOOD STOVE174

GypsumQuartzMicaCarbonatesBinder/Filler

100%

Fibrous GlassNoShingle/ Tar, Black/ Brown None Detected0252734-175 PUMP HOUSE

175

15%

CarbonatesQuartzBinder/Filler

85%

Cellulose FiberFibrous Glass

NoGypsum Wallboard, White/ BrownNote: No Joint Compound or Texture Present

None Detected0252734-176 PUMP HOUSE

176

10%2%

GypsumCarbonatesMicaQuartz

88%

NoFoam Insulation, Pink None Detected0252734-177 SHOP

177 Foam 100%

Fibrous GlassNoFiberglass Insulation, Pink None Detected0252734-178 SHOP

178

100%

Fibrous GlassNoLAYER 1Fiberglass Insulation, Yellow

None Detected0252734-179 SHOP

179

100%

Synthetic FiberCellulose Fiber

NoLAYER 2Vapor Barrier, White/ Lt. Brown

None Detected 60%10%

CarbonatesBinder/Filler

30%

Page 57 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberFibrous Glass

NoGypsum Wallboard, White/ BrownNote: No Joint Compound or Texture Present

None Detected0252734-180 SHOP

180

10%2%

GypsumCarbonatesMica

88%

Cellulose FiberNoGypsum Wallboard, White/ BrownNote: No Joint Compound or Texture Present

None Detected0252734-181 SHOP

181

12%

GypsumCarbonatesMica

88%

Cellulose FiberYesLAYER 1Residual Paper Backing, Lt. Gray

Chrysotile0252734-182 KITCHEN - ADDITIONAL LAYERS

069

30% 30%

CarbonatesGypsumBinder/Filler

40%

Cellulose FiberYesLAYER 2Mastic, BrownNote: Difficult to separate adjacent layer

Chrysotile 3% 2%

GypsumCarbonatesBinder/Filler

95%

Cellulose FiberSynthetic Fiber

NoLAYER 3Sheet Vinyl, Beige/ Black

None Detected 20%5%

CarbonatesGypsumBinder/Filler

75%

Cellulose FiberNoLAYER 4Mastic, Brown

None Detected 2%

CarbonatesGypsumBinder/Filler

98%

Page 58 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberYesLAYER 1Residual Paper Backing, Lt. Gray

Chrysotile0252734-183 KITCHEN - ADDITIONAL LAYERS

070

30% 30%

CarbonatesGypsumBinder/Filler

40%

Cellulose FiberYesLAYER 2Mastic, BrownNote: Difficult to separate adjacent layer

Chrysotile 3% 2%

GypsumCarbonatesBinder/Filler

95%

Cellulose FiberSynthetic Fiber

NoLAYER 3Sheet Vinyl, Beige/ Black

None Detected 20%5%

CarbonatesGypsumBinder/Filler

75%

Cellulose FiberNoLAYER 4Mastic, Brown

None Detected 2%

CarbonatesGypsumBinder/Filler

98%

Page 59 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252734

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/23/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/12/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/23/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Signatory - Lab Director - Kurt Kettler

Distinctly stratified, easily separable layers of samples are analyzed as subsamples of the whole and are reported separately for each discernible layer. All analyses are derived from calibrated visual estimate and measured in area percent unless otherwise noted. The report applies to the standards or procedures identified and to the sample(s) tested. The test results are not necessarily indicated or representative of the qualities of the lot from which the sample was taken or of apparently identical or similar products, nor do they represent an ongoing quality assurance program unless so noted. These reports are for the exclusive use of the addressed client and that they will not be reproduced wholly or in part for advertising or other purposes over our signature or in connection with our name without special written permission. The report shall not be reproduced except in full, without written approval by our laboratory. The samples not destroyed in testing are retained a maximum of thirty days. The laboratory measurement of uncertainty for the test method is approximately less than 1 by area percent. Accredited by the National Institute of Standards and Technology, Voluntary Laboratory Accreditation Program for selected test method for asbestos. The accreditation or any reports generated by this laboratory in no way constitutes or implies product certification, approval, or endorsement by the National Institute of Standards and Technology. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Polarized Light Microscopy may not be consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials.

Analyst - Johann Hofer

Analyst: Test Date: Samples Tested:

Johann Hofer 04/23/2021 252734001 252734002 252734003 252734004 252734005 252734006 252734007 252734008 252734009 252734010 252734011 252734012 252734013 252734014 252734015 252734016 252734017 252734018 252734019 252734020 252734021 252734022 252734023 252734024 252734025 252734026 252734027 252734028 252734029 252734030 252734031 252734032 252734033 252734034 252734035 252734036 252734037 252734038 252734039 252734040 252734041 252734042 252734043 252734044 252734045 252734046 252734047 252734048 252734049 252734050 252734051 252734052 252734053 252734054 252734055 252734056 252734057 252734058 252734059 252734060 252734061 252734062 252734063 252734064 252734065 252734066 252734067 252734068 252734069 252734070 252734071 252734072 252734073 252734074 252734075 252734076 252734077 252734078 252734079 252734080 252734081 252734082 252734083 252734084 252734085 252734086 252734087 252734088 252734089 252734090 252734091 252734092 252734093 252734094 252734095 252734096 252734097 252734098 252734099 252734100 252734101 252734102 252734103 252734104 252734105 252734106 252734107 252734108 252734109 252734110 252734111 252734112 252734113 252734114 252734115 252734116 252734117 252734118 252734119 252734120 252734121 252734122 252734123 252734124 252734125 252734126 252734127 252734128 252734129 252734130 252734131 252734132 252734133 252734134 252734135 252734136 252734137 252734138 252734139 252734140 252734141 252734142 252734143 252734144 252734145 252734146 252734147 252734148 252734149 252734150 252734151 252734152 252734153 252734154 252734155 252734156 252734157 252734158 252734159 252734160 252734161 252734162 252734163 252734164 252734165 252734166 252734167 252734168 252734169 252734170 252734171 252734172 252734173 252734174 252734175 252734176 252734177 252734178 252734179 252734180 252734181

Kenneth Scheske 04/23/2021 252734182 252734183

Page 60 of 60

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoFiber Ceiling, White None Detected0252735-001 49683 RIVER-KITCHEN182

95%

GypsumBinder/Filler

5%

Cellulose FiberNoFiber Ceiling, White None Detected0252735-002 LAUNDRY RM

183

95%

GypsumBinder/Filler

5%

Cellulose FiberNoLAYER 1Counter Top, White

None Detected0252735-003 N. BATHRM, COUNTER TOP184

70%

GypsumBinder/Filler

30%

Cellulose FiberNoLAYER 2Mastic, Red

None Detected 1%

GypsumQuartzBinder/Filler

99%

NoWall Texture, Brown None Detected0252735-004 N. BATHRM

185 CarbonatesQuartzBinder/Filler

100%

NoShower Caulk, White None Detected0252735-005 BATHRM, SHOWER

186 Silicone 100%

Synthetic FiberNoLAYER 1Carpet, Cream

None Detected0252735-006 E. LIVING RM

187

85%

CarbonatesBinder/Filler

15%

NoLAYER 2Foam, Gray/Purple

None Detected

Foam 100%

Page 1 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoLAYER 1Wood Laminate Floor, Brown

None Detected0252735-007 KITCHEN

188 CarbonatesQuartzBinder/Filler

100%

Cellulose FiberNoLAYER 2Mastic, YellowNote: Very small amount of mastic

None Detected <1%

CarbonatesGypsumQuartzBinder/Filler

99%

Cellulose FiberSynthetic Fiber

NoLAYER 1Sheet Vinyl, White

None Detected0252735-008 N. LAUNDRY RM

189

15%5%

CarbonatesGypsumBinder/Filler

80%

Cellulose FiberSynthetic Fiber

NoLAYER 2Mastic, Yellow

None Detected 3%<1%

CarbonatesGypsumQuartzBinder/Filler

96%

NoLAYER 1Wood Laminate, Brown

None Detected0252735-009 KITCHEN

190 CarbonatesQuartzBinder/Filler

100%

NoLAYER 2Mastic, Yellow/Gray

None Detected

CarbonatesGypsumQuartzBinder/Filler

100%

Page 2 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberSynthetic Fiber

NoLAYER 1Sheet Vinyl, White

None Detected0252735-010 BATHRM

191

15%5%

CarbonatesGypsumQuartzBinder/Filler

80%

Cellulose FiberNoLAYER 2Mastic, Yellow

None Detected 3%

CarbonatesGypsumQuartzBinder/Filler

97%

Synthetic FiberNoLAYER 1Carpet, Tan Mottled

None Detected0252735-011 N. BEDRM

192

85%

CarbonatesBinder/Filler

15%

NoLAYER 2Foam, Gray/Blue

None Detected

Foam 100%

Cellulose FiberNoVapor Barrier, Black None Detected0252735-012 FLOOR BOARDS

193

65%

GypsumBinder/Filler

35%

Cellulose FiberNoLAYER 1Fiber Board Panel, Brown

None Detected0252735-013 NW EXT.

194

98%

GypsumBinder/Filler

2%

Cellulose FiberNoLAYER 2Mastic, YellowNote: Difficult to separate adjacent layer

None Detected 3%

CarbonatesGypsumBinder/Filler

97%

Page 3 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1Fiber Board Panel, Brown

None Detected0252735-014 EXT. WALL

195

98%

GypsumBinder/Filler

2%

Cellulose FiberNoLAYER 2Mastic, YellowNote: Difficult to separate adjacent layer

None Detected 3%

CarbonatesGypsumBinder/Filler

97%

Fibrous GlassNoInsulation, Yellow None Detected0252735-015 EXT. WALL

196

100%

NoWindow Frame Caulk, White None Detected0252735-016 EXT. WINDOWS

197 Silicone 100%

Cellulose FiberSynthetic Fiber

NoLAYER 1Shingle, Black/ White

None Detected0252735-017 ROOF

198

17%3%

CarbonatesGypsumQuartzBinder/Filler

80%

YesLAYER 2Mastic, Black

Chrysotile 5%

CarbonatesQuartzBinder/Filler

95%

Cellulose FiberSynthetic Fiber

NoLAYER 1Shingle, Black/ White

None Detected0252735-018 ROOF

199

17%3%

CarbonatesGypsumQuartzBinder/Filler

80%

YesLAYER 2Mastic, Black

Chrysotile 5%

CarbonatesQuartzBinder/Filler

95%

Page 4 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoVapor Barrier, Black None Detected0252735-019 SHOP

200

60%

CarbonatesGypsumBinder/Filler

40%

Cellulose FiberNoVapor Barrier, Black None Detected0252735-020 SHOP

201

60%

CarbonatesGypsumBinder/Filler

40%

YesLAYER 1Tar, Black

Chrysotile0252735-021 EXTERIOR SHOP, SOUTH202

3%

CarbonatesQuartzBinder/Filler

97%

YesLAYER 2Compound, Yellow

Chrysotile <1%

CarbonatesGypsumQuartzBinder/Filler

99%

Cellulose FiberNoRoof Vapor Barrier, Black None Detected0252735-022 SMALL SHED, ROOF203

60%

CarbonatesGypsumBinder/Filler

40%

Cellulose FiberNoLAYER 1Wrap, Brown

None Detected0252735-023 52153 CAYUSE-INTERIOR WALLS204

95%

CarbonatesBinder/Filler

5%

Fibrous GlassCellulose Fiber

NoLAYER 2Insulation, Pink

None Detected 98%2%

Page 5 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1Vapor Barrier, Black

None Detected0252735-024 E. BATHRM, SHOWER205

60%

GypsumBinder/Filler

40%

Cellulose FiberFibrous Glass

NoLAYER 2Tar, Black

None Detected 8%2%

CarbonatesQuartzBinder/Filler

90%

Cellulose FiberNoFloral Wall Paper, White None Detected0252735-025 N. FAMILY RM

206

98%

GypsumBinder/Filler

2%

Fibrous GlassNoInsulation, Yellow None Detected0252735-026 W. INTERIOR WALL

207

100%

Fibrous GlassNoLAYER 1Wrap Insulation, Silver/Pink

None Detected0252735-027 INT. WALLS

208

95%

CarbonatesBinder/Filler

5%

Fibrous GlassCellulose Fiber

NoLAYER 2Vapor Barrier, Black

None Detected 55%5%

GypsumBinder/Filler

40%

NoDoor /Window Frame Caulk, Yellow/Green

None Detected0252735-028 EXT. DOOR/WINDOWS209

CarbonatesQuartzBinder/Filler

100%

NoPenetration Sealant, Clear None Detected0252735-029 EXT. ROOF

210 Silicone 100%

Page 6 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoVapor Barrier Felt, Black None Detected0252735-030 EXT. ROOF

211

60%

GypsumQuartzBinder/Filler

40%

Cellulose FiberNoVapor Barrier Felt, Black None Detected0252735-031 EXT. ROOF

212

60%

GypsumQuartzBinder/Filler

40%

Cellulose FiberNoLAYER 1Vapor Barrier, Black

None Detected0252735-032 E. BATHRM

213

60%

GypsumBinder/Filler

40%

Cellulose FiberFibrous Glass

NoLAYER 2Tar, Black

None Detected 6%4%

CarbonatesQuartzBinder/Filler

90%

Fibrous GlassNoLAYER 1Insulation, Brown

None Detected0252735-033 NORTH INT. WALLS

214

98%

Binder/Filler 2%

Cellulose FiberNoLAYER 2Paper, Off White

None Detected 98%

GypsumBinder/Filler

2%

NoLAYER 1Laminate Floor Tile, Gray/ Black

None Detected0252735-034 SHOP

215 CarbonatesQuartzBinder/Filler

100%

Cellulose FiberNoLAYER 2Mastic, Yellow

None Detected 2%

CarbonatesGypsumQuartzBinder/Filler

98%

Page 7 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoLAYER 1Laminate Floor Tile, Gray/ Black

None Detected0252735-035 SHOP

216 CarbonatesQuartzBinder/Filler

100%

Cellulose FiberNoLAYER 2Mastic, Yellow

None Detected 3%

CarbonatesGypsumQuartzBinder/Filler

97%

NoDoor Caulk, White None Detected0252735-036 SHOP, DOOR (EXT.)

217 CarbonatesQuartzBinder/Filler

100%

Fibrous GlassNoLAYER 1Insulation, Yellow

None Detected0252735-037 SHOP/GARAGE

218

100%

Cellulose FiberFibrous Glass

NoLAYER 2Vapor Barrier, Black/ Brown

None Detected 80%5%

CarbonatesGypsumBinder/Filler

15%

Cellulose FiberFibrous Glass

NoLAYER 1Wrap, Silver/ Black/ BrownNote: Difficult to separate adjacent layer

None Detected0252735-038 PUMPHOUSE

219

60%5%

AluminumGypsumBinder/Filler

35%

Fibrous GlassNoLAYER 2Insulation, Pink

None Detected 100%

Cellulose FiberNoVertical Striped Wall Paneling, Yellow/ Dk. Brown

None Detected0252735-039 SHOP

220

90%

CarbonatesGypsumBinder/Filler

10%

Page 8 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoRoofing Vapor Bsrrier, Black None Detected0252735-040 SHOP/GARAGE

221

70%

GypsumBinder/Filler

30%

Cellulose FiberNoRoofing Vapor Bsrrier, Black None Detected0252735-041 SHOP/GARAGE

222

70%

GypsumBinder/Filler

30%

Cellulose FiberFibrous Glass

NoLAYER 1Gypsum Wallboard, White/ Brown

None Detected0252735-042 E. BATHRM

223

10%2%

GypsumCarbonatesQuartzMica

88%

Cellulose FiberNoLAYER 2Tape, Beige

None Detected 98%

Carbonates 2%

NoLAYER 3Joint Compound, Off White

None Detected

CarbonatesMicaQuartzPerliteBinder/Filler

100%

Cellulose FiberNoLAYER 1Gypsum Wallboard, White/ Brown

None Detected0252735-043 E. HALL

224

12%

GypsumCarbonatesQuartzMica

88%

YesLAYER 2Joint Compound, Off White/ Lt. Green

Chrysotile 3%

CarbonatesMicaQuartzBinder/Filler

97%

Page 9 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1Gypsum Wallboard, White/ Brown

None Detected0252735-044 NE RM

225

12%

GypsumCarbonatesQuartzMica

88%

NoLAYER 2Joint Compound, Off White

None Detected

CarbonatesMicaQuartzBinder/Filler

100%

Cellulose FiberNoLAYER 1Gypsum Wallboard, White/ Brown

None Detected0252735-045 KITCHEN

226

12%

GypsumCarbonatesQuartzMica

88%

YesLAYER 2Joint Compound, Off White/ Lt. Green

Chrysotile 3%

CarbonatesMicaQuartzBinder/Filler

97%

Cellulose FiberNoLAYER 1Gypsum Wallboard, White/ Brown

None Detected0252735-046 N. FAMILY RM

227

12%

GypsumCarbonatesQuartzMica

88%

Cellulose FiberNoLAYER 2Tape, Beige

None Detected 98%

Carbonates 2%

NoLAYER 3Joint Compound, WhiteNote: Difficult to separate adjacent layer

None Detected

CarbonatesGypsumQuartzPerliteBinder/Filler

100%

Page 10 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1Gypsum Wallboard, White/ Brown

None Detected0252735-047 52277 CAYUSE-INTERIOR WALLS228

12%

GypsumCarbonatesQuartzMica

88%

NoLAYER 2Joint Compound, White

None Detected

GypsumQuartzCarbonatesMicaBinder/Filler

100%

Cellulose FiberNoLAYER 1Gypsum Wallboard, White/ Brown

None Detected0252735-048 INTERIOR KITCHEN

229

12%

GypsumCarbonatesQuartzMica

88%

NoLAYER 2Joint Compound, White

None Detected

GypsumQuartzCarbonatesMicaBinder/Filler

100%

Cellulose FiberNoLAYER 1Gypsum Wallboard, White/ Brown

None Detected0252735-049 INTERIOR HALL

230

12%

GypsumCarbonatesQuartzMica

88%

NoLAYER 2Joint Compound, White

None Detected

CarbonatesMicaQuartzBinder/Filler

100%

Page 11 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1Gypsum Wallboard, White/ Brown

None Detected0252735-050 INTERIOR HALL

231

12%

GypsumCarbonatesQuartzMica

88%

NoLAYER 2Joint Compound, White

None Detected

CarbonatesMicaQuartzBinder/Filler

100%

Cellulose FiberNoLAYER 3Tape, Beige

None Detected 98%

Carbonates 2%

NoLAYER 4Joint Compound, Beige

None Detected

CarbonatesMicaQuartzBinder/Filler

100%

Cellulose FiberNoLAYER 1Gypsum Wallboard, White/ Brown

None Detected0252735-051 INTERIOR LAUNDRY RM232

12%

GypsumCarbonatesQuartzMica

88%

Cellulose FiberNoLAYER 2Tape, Beige

None Detected 98%

Carbonates 2%

NoLAYER 3Joint Compound/ Paint, White

None Detected

CarbonatesMicaQuartzPerliteBinder/Filler

100%

Page 12 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberYesLAYER 1Sheet Flooring, Brown/ Beige

Chrysotile0252735-052 INDOOR WELL

233

15% 5%

CarbonatesQuartzBinder/Filler

80%

Cellulose FiberYesLAYER 2Mastic, BrownNote: Difficult to separate adjacent layer

Chrysotile 3% <1%

CarbonatesGypsumQuartzBinder/Filler

96%

Fibrous GlassNoInsulation, Gray None Detected0252735-053 INT. WALL, STOVE

234

100%

NoGrout, Gray None Detected0252735-054 HEARTH

235 QuartzGypsumCarbonatesMicaBinder/Filler

100%

Cellulose FiberFibrous Glass

NoLAYER 1Sheet Vinyl, Gray/ White

None Detected0252735-055 DOWNSTAIRS, INT.

236

17%3%

CarbonatesQuartzBinder/Filler

80%

NoLAYER 2CM Mastic, Yellow

None Detected

CarbonatesGypsumQuartzBinder/Filler

100%

Cellulose FiberNoWainscoting Mastic, Yellow None Detected0252735-056 KITCHEN

237

<1%

CarbonatesGypsumQuartzBinder/Filler

99%

Page 13 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoCaulk, White None Detected0252735-057 INTERIOR, LOG WALLS238

CarbonatesQuartzBinder/Filler

100%

NoCarpet Foam, Green/ Yellow None Detected0252735-058 CARPETED AREAS

239 Foam 100%

Cellulose FiberNoRoofing Vapor Barrier, Black None Detected0252735-059 MAIN EXT. ROOF

240

70%

CarbonatesGypsumBinder/Filler

30%

Cellulose FiberNoRoofing Vapor Barrier, Black None Detected0252735-060 MAIN EXT. ROOF

241

70%

CarbonatesGypsumBinder/Filler

30%

YesTar/Sealant, Black Chrysotile0252735-061 MAIN EXT., LOG WALL242

15%

CarbonatesQuartzBinder/Filler

85%

YesTar/Sealant, Black Chrysotile0252735-062 MAIN EXT., LOG WALL243

15%

CarbonatesQuartzBinder/Filler

85%

NoFoam Insulation, Yellow None Detected0252735-063 W. EXTERIOR

244 Foam 100%

Page 14 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoExterior Window Frame Caulk, Clear

None Detected0252735-064 EXT. WINDOW FRAME245

Silicone 100%

NoExterior Door Frame Caulk, Clear None Detected0252735-065 EXT. DOOR FRAME

246 Silicone 100%

Fibrous GlassNoLAYER 1Roof Sealant, Green/Black

None Detected0252735-066 C

247

15%

CarbonatesQuartzBinder/Filler

85%

Fibrous GlassNoLAYER 2Roof Tar, Black

None Detected <1%

CarbonatesQuartzBinder/Filler

99%

Fibrous GlassNoLAYER 1Roof Sealant, Green/Black

None Detected0252735-067 MAIN EXT., LOG WALL248

15%

CarbonatesQuartzBinder/Filler

85%

Cellulose FiberNoLAYER 2Roof Tar, Black

None Detected <1%

CarbonatesQuartzBinder/Filler

99%

Cellulose FiberNoLAYER 1Vapor Barrier, White

None Detected0252735-068 SHOP

249

85%

CarbonatesGypsumBinder/Filler

15%

Cellulose FiberNoLAYER 2Tape, Yellow

None Detected 65%

GypsumBinder/Filler

35%

Page 15 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoGypsum Board Ceiling, White/ Brown

None Detected0252735-069 SHOP

250

12%

GypsumCarbonatesQuartzMica

88%

Cellulose FiberNoGypsum Board Ceiling, White/ Brown

None Detected0252735-070 SHOP

251

12%

GypsumCarbonatesQuartzMica

88%

Cellulose FiberNoGypsum Board Ceiling, White/ Brown

None Detected0252735-071 SHOP

252

12%

GypsumCarbonatesQuartzMica

88%

Cellulose FiberYesLAYER 1Sheet Vinyl, Brown/ Mosaic

Chrysotile0252735-072 SHOP TRAILER

253

18% 2%

CarbonatesQuartzBinder/Filler

80%

Cellulose FiberYesLAYER 2Mastic, Yellow

Chrysotile 2% 1%

CarbonatesGypsumQuartzBinder/Filler

97%

Page 16 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberYesLAYER 1Sheet Vinyl, Brown/ Mosaic

Chrysotile0252735-073 SHOP TRAILER

254

18% 2%

CarbonatesQuartzBinder/Filler

80%

Cellulose FiberYesLAYER 2Mastic, Yellow

Chrysotile 2% 1%

CarbonatesGypsumQuartzBinder/Filler

97%

YesSpray-On, Black Chrysotile0252735-074 SHOP TRAILER

255

5%

CarbonatesMicaQuartzPerliteBinder/Filler

95%

YesSpray-On, Black Chrysotile0252735-075 SHOP TRAILER

256

5%

CarbonatesMicaQuartzPerliteBinder/Filler

95%

NoLAYER 1Cove Base, Gray

None Detected0252735-076 SHOP TRAILER

257 CarbonatesQuartzBinder/Filler

100%

NoLAYER 2Mastic, Yellow

None Detected

CarbonatesQuartzBinder/Filler

100%

Page 17 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoLAYER 1Cove Base, Gray

None Detected0252735-077 SHOP TRAILER

258 CarbonatesQuartzBinder/Filler

100%

NoLAYER 2Mastic, Yellow

None Detected

CarbonatesQuartzBinder/Filler

100%

NoFoam Insulation, Yellow None Detected0252735-078 MOTHER-IN-LAW

259 Foam 100%

NoWindow Caulk, Tan None Detected0252735-079 MOTHER-IN-LAW, S. INT.260

CarbonatesQuartzBinder/Filler

100%

Cellulose FiberFibrous Glass

NoSheet Vinyl, White/ Off WhiteNote: No Mastic Present

None Detected0252735-080 MOTHER-IN-LAW, UPSTAIRS261

18%2%

CarbonatesQuartzBinder/Filler

80%

Cellulose FiberFibrous Glass

NoSheet Vinyl, White/ Off WhiteNote: No Mastic Present

None Detected0252735-081 MOTHER-IN-LAW, UPSTAIRS262

18%2%

CarbonatesQuartzBinder/Filler

80%

NoWindow Glazing, Off White/ White None Detected0252735-082 MOTHER-IN-LAW, S. INT. UPST.263

CarbonatesQuartzBinder/Filler

100%

Page 18 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoLAYER 1Counter Top, Gray/ Brown

None Detected0252735-083 MOTHER-IN-LAW, KITCHEN264

90%

GypsumBinder/Filler

10%

Cellulose FiberNoLAYER 2Mastic, Yellow

None Detected 3%

GypsumQuartzBinder/Filler

97%

Cellulose FiberNoLAYER 1Wallpaper, White/ Yellow/ Green

None Detected0252735-084 MOTHER-IN-LAW, N. WALL265

98%

GypsumBinder/Filler

2%

Cellulose FiberFibrous Glass

NoLAYER 2Drywall, White/ Brown/ Off White

None Detected 10%2%

GypsumCarbonatesQuartzMica

88%

NoSealant, Gray None Detected0252735-085 MOTHER-IN-LAW, INTERIOR266

CarbonatesQuartzBinder/Filler

100%

Synthetic FiberNoVapor Barrier, White None Detected0252735-086 MOTHER-IN-LAW, WALLS267

90%

GypsumBinder/Filler

10%

Cellulose FiberNoTar/ Sealant, Black None Detected0252735-087 MOTHER-IN-LAW, EXT. WALLS268

10%

CarbonatesQuartzBinder/Filler

90%

Page 19 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoLAYER 1Brick, Tan

None Detected0252735-088 MOTHER-IN-LAW, FIREPLACE269

GypsumQuartzBinder/Filler

100%

NoLAYER 2Mortar, Gray

None Detected

QuartzGypsumCarbonatesMicaBinder/Filler

100%

NoLog Caulk, White None Detected0252735-089 MOTHER-IN-LAW, UPSTAIRS270

CarbonatesQuartzBinder/Filler

100%

Cellulose FiberFibrous Glass

NoLAYER 1Gypsum Wallboard, White/ Brown

None Detected0252735-090 MOTHER-IN-LAW

271

10%2%

GypsumCarbonatesQuartzMica

88%

Cellulose FiberNoLAYER 2Tape, Cream

None Detected 98%

Carbonates 2%

NoLAYER 3Joint Compound, Off White/ White

None Detected

CarbonatesMicaQuartzBinder/Filler

100%

Page 20 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberFibrous Glass

NoLAYER 1Gypsum Wallboard, White/ Brown

None Detected0252735-091 MOTHER-IN-LAW

272

10%2%

GypsumCarbonatesQuartzMica

88%

Cellulose FiberNoLAYER 2Tape, Cream

None Detected 98%

Carbonates 2%

NoLAYER 3Joint Compound, Off White/ White

None Detected

CarbonatesMicaQuartzBinder/Filler

100%

Cellulose FiberFibrous Glass

NoLAYER 1Gypsum Wallboard, White/ Brown

None Detected0252735-092 MOTHER-IN-LAW

273

10%2%

GypsumCarbonatesQuartzMica

88%

Cellulose FiberNoLAYER 2Tape, Cream

None Detected 98%

Carbonates 2%

NoLAYER 3Joint Compound, Off White/ White

None Detected

CarbonatesMicaQuartzBinder/Filler

100%

Synthetic FiberNoCarpet, Green None Detected0252735-093 MOTHER-IN-LAW

274

90%

CarbonatesBinder/Filler

10%

Cellulose FiberNoLog Tar/ Sealant, Black None Detected0252735-094 MOTHER-IN-LAW

275

10%

CarbonatesQuartzBinder/Filler

90%

Page 21 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Mineral WoolNoWall/ Ceiling Insulation, White None Detected0252735-095 53017 CAYUSE ROAD-MAIN, STORAGE RM WALL/CEILING

276

98%

Gypsum 2%

NoDuct Tape, Silver None Detected0252735-096 MAIN, GARAGE, DUCT277

Aluminum 100%

Fibrous GlassNoInsulation, Yellow None Detected0252735-097 GARAGE, WALL/CEILING278

97%

CarbonatesGypsum

3%

Cellulose FiberYesWall Texture, White Chrysotile0252735-098 SE BEDRM

279

3% 2%

CarbonatesMicaQuartzBinder/Filler

95%

YesPopcorn Ceiling Texture, White/ Off White

Chrysotile0252735-099 SE BEDRM

280

7%

CarbonatesMicaQuartzBinder/Filler

93%

YesPopcorn Ceiling Texture, White/ Off White

Chrysotile0252735-100 FAMILY RM

281

5%

CarbonatesMicaQuartzBinder/Filler

95%

Page 22 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

YesPopcorn Ceiling Texture, White/ Off White

Chrysotile0252735-101 HALLWAY

282

5%

CarbonatesMicaQuartzBinder/Filler

95%

NoRock & Grout, Gray None Detected0252735-102 FIREPLACE, HEARTH283

QuartzGypsumCarbonatesMicaBinder/Filler

100%

Cellulose FiberNoLAYER 1Subflooring, Brown

None Detected0252735-103 SE BATH, FLOORING284

98%

GypsumBinder/Filler

2%

Cellulose FiberNoLAYER 2Debris, Brown

None Detected 2%

GypsumQuartzOrganic Matrix

98%

Page 23 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoLAYER 1Laminate, Wood Grain/ Brown/ BlackNote: Insufficient Mastic/Adhesive for Analysis

None Detected0252735-104 SE BATH

285 CarbonatesQuartzBinder/Filler

100%

Cellulose FiberYesLAYER 2Sheet Vinyl, Beige/ Off White

Chrysotile 15% 5%

CarbonatesQuartzBinder/Filler

80%

Cellulose FiberYesLAYER 3Mastic, YellowNote: Difficult to separate adjacent layers

Chrysotile 3% 2%

CarbonatesGypsumQuartzBinder/Filler

95%

Cellulose FiberSynthetic Fiber

NoLAYER 4Vapor Barrier, Black

None Detected 45%5%

CarbonatesGypsumBinder/Filler

50%

Page 24 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoLAYER 1Laminate, Wood Grain/ Brown/ BlackNote: Insufficient Mastic/Adhesive for Analysis

None Detected0252735-105 SE BATH

286 CarbonatesQuartzBinder/Filler

100%

Cellulose FiberYesLAYER 2Sheet Vinyl, Beige/ Off White

Chrysotile 15% 5%

CarbonatesQuartzBinder/Filler

80%

Cellulose FiberYesLAYER 3Mastic, YellowNote: Difficult to separate adjacent layers

Chrysotile 3% 2%

CarbonatesGypsumQuartzBinder/Filler

95%

Cellulose FiberSynthetic Fiber

NoLAYER 4Vapor Barrier, Black

None Detected 45%5%

CarbonatesGypsumBinder/Filler

50%

Cellulose FiberNoLAYER 1Counter Top, Beige/ Brown

None Detected0252735-106 SE BATH, COUNTER TOP287

65%

GypsumBinder/Filler

35%

Cellulose FiberNoLAYER 2Mastic, Yellow

None Detected 5%

GypsumBinder/Filler

95%

NoCaulk, White/ Off White None Detected0252735-107 SE BATH, SHOWER

288 CarbonatesQuartzBinder/Filler

100%

Page 25 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoCeramic Grout, Gray None Detected0252735-108 NW BATH

289 QuartzGypsumCarbonatesMicaBinder/Filler

100%

NoLAYER 1Ceramic Grout, Gray

None Detected0252735-109 NW BATH

290 QuartzGypsumCarbonatesMicaBinder/Filler

100%

NoLAYER 2Ceramic Tile, White/ Red

None Detected

GypsumQuartzBinder/Filler

100%

Cellulose FiberNoLAYER 1Shingle, Black/ White/ Green

None Detected0252735-110 HORSE STALL ROOF291

20%

CarbonatesGypsumQuartzBinder/Filler

80%

Cellulose FiberNoLAYER 2Tar, BlackNote: Vaery small amount of tar

None Detected 5%

CarbonatesGypsumQuartzBinder/Filler

95%

NoInsulation Foam, Yellow None Detected0252735-111 PUMP HOUSE

292 Foam 100%

Page 26 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberNoVapor Barrier, Black/ Brown None Detected0252735-112 PUMP HOUSE, ROOF293

40%

CarbonatesGypsumBinder/Filler

60%

Cellulose FiberNoShingle, Black/ White/ GreenNote: No Tar Present

None Detected0252735-113 PUMP HOUSE, ROOF294

20%

CarbonatesQuartzBinder/Filler

80%

Cellulose FiberFibrous Glass

NoLAYER 1Gypsum Wallboard, White/ Brown

None Detected0252735-114 E. TOOL SHED

295

10%2%

GypsumCarbonatesQuartzMica

88%

NoLAYER 2Joint Compound, White/ Beige

None Detected

CarbonatesMicaQuartzPerliteBinder/Filler

100%

Cellulose FiberFibrous Glass

NoLAYER 1Gypsum Wallboard, White/ Brown

None Detected0252735-115 E. TOOL SHED

296

10%2%

GypsumCarbonatesQuartzMica

88%

NoLAYER 2Joint Compound, Beige

None Detected

CarbonatesMicaQuartzPerliteBinder/Filler

100%

Page 27 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberFibrous Glass

NoLAYER 1Gypsum Wallboard, White/ Brown

None Detected0252735-116 E. TOOL SHED

297

10%2%

GypsumCarbonatesQuartzMica

88%

NoLAYER 2Joint Compound, White

None Detected

CarbonatesMicaQuartzPerliteBinder/Filler

100%

Cellulose FiberNoPaneling, Dk. Red/ Gray None Detected0252735-117 E. STUDIO, EXTERIOR298

15%

CarbonatesGypsumBinder/Filler

85%

Cellulose FiberFibrous Glass

NoLAYER 1Gypsum Wallboard, White/ Brown

None Detected0252735-118 E. STUDIO, INTERIOR299

10%2%

GypsumCarbonatesQuartzMica

88%

NoLAYER 2Joint Compound, White

None Detected

CarbonatesMicaQuartzPerliteBinder/Filler

100%

Page 28 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberFibrous Glass

NoLAYER 1Gypsum Wallboard, White/ Brown

None Detected0252735-119 E. STUDIO, INTERIOR300

10%2%

GypsumCarbonatesQuartzMica

88%

NoLAYER 2Joint Compound, White

None Detected

CarbonatesMicaQuartzPerliteBinder/Filler

100%

Cellulose FiberFibrous Glass

NoLAYER 1Gypsum Wallboard, White/ Brown

None Detected0252735-120 E. STUDIO, INTERIOR301

10%2%

GypsumCarbonatesQuartzMica

88%

NoLAYER 2Joint Compound, White

None Detected

CarbonatesMicaQuartzPerliteBinder/Filler

100%

Cellulose FiberNoLAYER 1Gypsum Wallboard, White/ Brown

None Detected0252735-121 N. STUDIO/SHED, INT.302

12%

GypsumCarbonatesQuartzMica

88%

NoLAYER 2Joint Compound, White

None Detected

CarbonatesMicaQuartzPerliteBinder/Filler

100%

Page 29 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberFibrous Glass

NoLAYER 1Gypsum Wallboard, White/ Brown

None Detected0252735-122 N. STUDIO/SHED, INT.303

10%2%

GypsumCarbonatesQuartzMica

88%

NoLAYER 2Joint Compound, White

None Detected

CarbonatesMicaQuartzPerliteBinder/Filler

100%

Cellulose FiberFibrous Glass

NoLAYER 1Gypsum Wallboard, White/ Brown

None Detected0252735-123 N. STUDIO/SHED, INT.304

10%2%

GypsumCarbonatesQuartzMica

88%

NoLAYER 2Joint Compound, White

None Detected

CarbonatesMicaQuartzPerliteBinder/Filler

100%

Cellulose FiberNoVapor Barrier, Black/ Brown None Detected0252735-124 N. STUDIO/SHED, ROOF305

40%

GypsumBinder/Filler

60%

Page 30 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Cellulose FiberFibrous Glass

NoLAYER 1Sheet Vinyl, Brown/ BeigeNote: Wood Pattern

None Detected0252735-125 E. STUDIO

306

17%3%

CarbonatesQuartzBinder/Filler

80%

Cellulose FiberNoLAYER 2Mastic, Tan/ Black

None Detected <1%

CarbonatesGypsumQuartzBinder/Filler

99%

Cellulose FiberFibrous Glass

NoLAYER 1Sheet Vinyl, Brown/ BeigeNote: Wood Pattern

None Detected0252735-126 E. STUDIO

307

17%3%

CarbonatesQuartzBinder/Filler

80%

Cellulose FiberNoLAYER 2Mastic, Tan/ Black

None Detected <1%

CarbonatesGypsumQuartzBinder/Filler

99%

NoLAYER 14" Cove Base, Brown

None Detected0252735-127 E. STUDIO

308 CarbonatesQuartzBinder/Filler

100%

NoLAYER 2Mastic/ Leveling Compound, Cream/ WhiteNote: Difficult to separate adjacent layers

None Detected

CarbonatesQuartzGypsumBinder/Filler

100%

Page 31 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

NoLAYER 14" Cove Base, Brown

None Detected0252735-128 E. STUDIO

309 CarbonatesQuartzBinder/Filler

100%

NoLAYER 2Mastic/ Leveling Compound, Cream/ WhiteNote: Difficult to separate adjacent layers

None Detected

CarbonatesQuartzGypsumBinder/Filler

100%

Cellulose FiberNoLAYER 1Shingle, Black/ White/ Green

None Detected0252735-129 MAIN, ROOF

310

30%

CarbonatesGypsumQuartzBinder/Filler

70%

Cellulose FiberNoLAYER 2Tar, BlackNote: Vaery small amount of tar

None Detected 5%

CarbonatesGypsumQuartzBinder/Filler

95%

Cellulose FiberNoLAYER 1Shingle, Black/ White/ Green

None Detected0252735-130 MAIN, ROOF

311

30%

CarbonatesGypsumQuartzBinder/Filler

70%

Cellulose FiberNoLAYER 2Tar, BlackNote: Vaery small amount of tar

None Detected 5%

CarbonatesGypsumQuartzBinder/Filler

95%

Page 32 of 33

AsbestosDetected

Layer Name /Sample Description

Lab ID SampleLocation

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-AsbestosConstituents

Laboratory Report

0252735

NVLAP#101926-0

Client ID

Client:Address: 400 BRADLEY BLVD, STE 106

RICHLAND WA 99352

PBS ENGINEERING & ENVIRONMENTAL

Date Received: 04/20/2021

04/21/2021Date Analyzed:

67796.001Job# / P.O. #:

EMC LABS, INC.

Collected: 04/14/2021

EPA Method: Project Name: CTUIR FEMA HAZMAT SURVEY

Submitted By: CAITLIN GUNDERTAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

04/21/2021Date Reported:

EPA 600/R-93/116

Asbestos Type(%)

Signatory - Lab Director - Kurt Kettler

Distinctly stratified, easily separable layers of samples are analyzed as subsamples of the whole and are reported separately for each discernible layer. All analyses are derived from calibrated visual estimate and measured in area percent unless otherwise noted. The report applies to the standards or procedures identified and to the sample(s) tested. The test results are not necessarily indicated or representative of the qualities of the lot from which the sample was taken or of apparently identical or similar products, nor do they represent an ongoing quality assurance program unless so noted. These reports are for the exclusive use of the addressed client and that they will not be reproduced wholly or in part for advertising or other purposes over our signature or in connection with our name without special written permission. The report shall not be reproduced except in full, without written approval by our laboratory. The samples not destroyed in testing are retained a maximum of thirty days. The laboratory measurement of uncertainty for the test method is approximately less than 1 by area percent. Accredited by the National Institute of Standards and Technology, Voluntary Laboratory Accreditation Program for selected test method for asbestos. The accreditation or any reports generated by this laboratory in no way constitutes or implies product certification, approval, or endorsement by the National Institute of Standards and Technology. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Polarized Light Microscopy may not be consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials.

Analyst - Matt Kettler

Page 33 of 33

EMC LABS, INC.

9830 South 51st Street, Suite B-109 / PHOENIX, ARIZONA 85044 / 480-940-5294 or 800-362-3373 / FAX 480-893-1726

[email protected]

ANALYST: QA COORDINATOR: Jason Thompson Kurt Kettler

Ver. 11/30/08 Rev. 7/15/19

Page 1 of 5

LEAD (Pb) IN PAINT CHIP SAMPLES EMC SOP METHOD #L01/1 EPA SW-846 METHOD 7420

EMC LAB #: L85025 DATE RECEIVED: 04/20/21

CLIENT: PBS Engineering & Environmental

REPORT DATE: 04/21/21

DATE OF ANALYSIS: 04/21/21

CLIENT ADDRESS: 400 Bradley Blvd, Ste 106 Richland, WA 99352

P.O. NO.:

PROJECT NAME: CTUIR FEMA Haz Mat Survey PROJECT NO.: 67796.001

EMC # L85025-

SAMPLE DATE /21

CLIENT SAMPLE #

DESCRIPTION

REPORTING LIMIT

(%Pb by weight)

%Pb BY WEIGHT

1 04/12 1001 73479 Sampson - White, Interior, Brick 0.040 BRL

2 04/12 1002 73479 Sampson - Green, Interior, Walls 0.010 BRL

3 04/12 1003 73479 Sampson - Yellow, Interior, SW Bed, Wall 0.010 BRL

4 04/12 1004 73479 Sampson - White, Interior, NW Bed, Wall 0.023 0.031

5 04/12 1005 73479 Sampson – Blue, Interior, Bathroom Walls 0.016 0.021

6 04/12 1006 73479 Sampson – Beige, Interior, Walls 0.026 BRL

7 04/12 1007 73479 Sampson - Brown, Exterior, Walls 0.010 0.211 ^ = Dilution Factor Changed * = Excessive Substrate May Bias Sample Results BRL = Below Reportable Limits # = Very Small Amount Of Sample Submitted, May Affect Result This report applies to the standards or procedures identified and to the samples tested only. The test results are not necessarily indicative or representative of the qualities of the lot from which the sample was taken or of apparently identical or similar products, nor do they represent an ongoing quality assurance program unless so noted. Unless otherwise noted, all quality control analyses for the samples noted above were within acceptable limits. Where it is noted that a sample with excessive substrate was submitted for laboratory analysis, such analysis may be biased. The lead content of such sample may, in actuality, be greater than reported. EMC makes no warranty, express or implied, as to the accuracy of the analysis of samples noted to have been submitted with excessive substrate. Resampling is recommended in such situations to verify original laboratory results. EMC Labs, Inc. (ID 101586) is accredited by the AIHA Laboratory Accreditation Programs, LLC (AIHA-LAP, LLC) in the Environmental Lead accreditation program(s) for Paint, Settled Dust by Wipe, Soil and Airborne Dust Fields of Testing as documented by the Scope of Accreditation Certificate and associated Scope. AIHA-LAP, LLC accreditation complies with the ISO/IEC Standard 17025:2005. requirements. These reports are for the exclusive use of the addressed client and are rendered upon the condition that they will not be reproduced wholly or in part for advertising or other purposes over our signature or in connection with our name without special written permission. Samples not destroyed in testing are retained a maximum of sixty (60) days.

EMC LABS, INC.

9830 South 51st Street, Suite B-109 / PHOENIX, ARIZONA 85044 / 480-940-5294 or 800-362-3373 / FAX 480-893-1726

[email protected]

ANALYST: QA COORDINATOR: Jason Thompson Kurt Kettler

Ver. 11/30/08 Rev. 7/15/19

Page 2 of 5

LEAD (Pb) IN PAINT CHIP SAMPLES EMC SOP METHOD #L01/1 EPA SW-846 METHOD 7420

EMC LAB #: L85025 DATE RECEIVED: 04/20/21

CLIENT: PBS Engineering & Environmental

REPORT DATE: 04/21/21

DATE OF ANALYSIS: 04/21/21

CLIENT ADDRESS: 400 Bradley Blvd, Ste 106 Richland, WA 99352

P.O. NO.:

PROJECT NAME: CTUIR FEMA Haz Mat Survey PROJECT NO.: 67796.001

EMC # L85025-

SAMPLE DATE /21

CLIENT SAMPLE #

DESCRIPTION

REPORTING LIMIT

(%Pb by weight)

%Pb BY WEIGHT

8 04/12 1008 73479 Sampson - Brown, Exterior, Shed, Walls 0.011 BRL

9 04/12 1009 73479 Sampson - Red, Exterior, Door 0.037 BRL

10 04/12 1010 73479 Sampson - Blue, Exterior, Warehouse, Panel 0.417 BRL#

11 04/12 1011 73479 Sampson - Gray, Exterior, Warehouse, Panel 0.345 BRL#

12 04/12 1012 73499 Sampson - Paint Interior, Red, Living Rm, Wall 0.014 BRL

13 04/12 1013 73499 Sampson - Paint Interior, Teal, NE Bedroom, Wall 0.023 0.149

14 04/12 1014 73499 Sampson - Paint Interior, Green, Living Room, Wall

0.013 BRL

^ = Dilution Factor Changed * = Excessive Substrate May Bias Sample Results BRL = Below Reportable Limits # = Very Small Amount Of Sample Submitted, May Affect Result This report applies to the standards or procedures identified and to the samples tested only. The test results are not necessarily indicative or representative of the qualities of the lot from which the sample was taken or of apparently identical or similar products, nor do they represent an ongoing quality assurance program unless so noted. Unless otherwise noted, all quality control analyses for the samples noted above were within acceptable limits. Where it is noted that a sample with excessive substrate was submitted for laboratory analysis, such analysis may be biased. The lead content of such sample may, in actuality, be greater than reported. EMC makes no warranty, express or implied, as to the accuracy of the analysis of samples noted to have been submitted with excessive substrate. Resampling is recommended in such situations to verify original laboratory results. EMC Labs, Inc. (ID 101586) is accredited by the AIHA Laboratory Accreditation Programs, LLC (AIHA-LAP, LLC) in the Environmental Lead accreditation program(s) for Paint, Settled Dust by Wipe, Soil and Airborne Dust Fields of Testing as documented by the Scope of Accreditation Certificate and associated Scope. AIHA-LAP, LLC accreditation complies with the ISO/IEC Standard 17025:2005. requirements. These reports are for the exclusive use of the addressed client and are rendered upon the condition that they will not be reproduced wholly or in part for advertising or other purposes over our signature or in connection with our name without special written permission. Samples not destroyed in testing are retained a maximum of sixty (60) days.

EMC LABS, INC.

9830 South 51st Street, Suite B-109 / PHOENIX, ARIZONA 85044 / 480-940-5294 or 800-362-3373 / FAX 480-893-1726

[email protected]

ANALYST: QA COORDINATOR: Jason Thompson Kurt Kettler

Ver. 11/30/08 Rev. 7/15/19

Page 3 of 5

LEAD (Pb) IN PAINT CHIP SAMPLES EMC SOP METHOD #L01/1 EPA SW-846 METHOD 7420

EMC LAB #: L85025 DATE RECEIVED: 04/20/21

CLIENT: PBS Engineering & Environmental

REPORT DATE: 04/21/21

DATE OF ANALYSIS: 04/21/21

CLIENT ADDRESS: 400 Bradley Blvd, Ste 106 Richland, WA 99352

P.O. NO.:

PROJECT NAME: CTUIR FEMA Haz Mat Survey PROJECT NO.: 67796.001

EMC # L85025-

SAMPLE DATE /21

CLIENT SAMPLE #

DESCRIPTION

REPORTING LIMIT

(%Pb by weight)

%Pb BY WEIGHT

15 04/12 1015 73499 Sampson - Paint Interior, White, Kitchen, Wall 0.010 0.068

16 04/12 1016 73499 Sampson - Paint Exterior, Red, Wall/Trim 0.019 BRL

17 04/12 1017 73499 Sampson - Paint Exterior, Brown, Wall/Trim 0.015 0.332

18 04/12 1018 73499 Sampson - Paint Exterior, White, Pumphouse, Door

0.010 0.015

19 04/13 1019 49587 River - Exterior Paint, Beige, Wall/Trim 0.022 BRL

20 04/13 1020 49587 River - Exterior Paint, White, Doors/Trim 0.010 BRL ^ = Dilution Factor Changed * = Excessive Substrate May Bias Sample Results BRL = Below Reportable Limits # = Very Small Amount Of Sample Submitted, May Affect Result This report applies to the standards or procedures identified and to the samples tested only. The test results are not necessarily indicative or representative of the qualities of the lot from which the sample was taken or of apparently identical or similar products, nor do they represent an ongoing quality assurance program unless so noted. Unless otherwise noted, all quality control analyses for the samples noted above were within acceptable limits. Where it is noted that a sample with excessive substrate was submitted for laboratory analysis, such analysis may be biased. The lead content of such sample may, in actuality, be greater than reported. EMC makes no warranty, express or implied, as to the accuracy of the analysis of samples noted to have been submitted with excessive substrate. Resampling is recommended in such situations to verify original laboratory results. EMC Labs, Inc. (ID 101586) is accredited by the AIHA Laboratory Accreditation Programs, LLC (AIHA-LAP, LLC) in the Environmental Lead accreditation program(s) for Paint, Settled Dust by Wipe, Soil and Airborne Dust Fields of Testing as documented by the Scope of Accreditation Certificate and associated Scope. AIHA-LAP, LLC accreditation complies with the ISO/IEC Standard 17025:2005. requirements. These reports are for the exclusive use of the addressed client and are rendered upon the condition that they will not be reproduced wholly or in part for advertising or other purposes over our signature or in connection with our name without special written permission. Samples not destroyed in testing are retained a maximum of sixty (60) days.

EMC LABS, INC.

9830 South 51st Street, Suite B-109 / PHOENIX, ARIZONA 85044 / 480-940-5294 or 800-362-3373 / FAX 480-893-1726

[email protected]

ANALYST: QA COORDINATOR: Jason Thompson Kurt Kettler

Ver. 11/30/08 Rev. 7/15/19

Page 4 of 5

LEAD (Pb) IN PAINT CHIP SAMPLES EMC SOP METHOD #L01/1 EPA SW-846 METHOD 7420

EMC LAB #: L85025 DATE RECEIVED: 04/20/21

CLIENT: PBS Engineering & Environmental

REPORT DATE: 04/21/21

DATE OF ANALYSIS: 04/21/21

CLIENT ADDRESS: 400 Bradley Blvd, Ste 106 Richland, WA 99352

P.O. NO.:

PROJECT NAME: CTUIR FEMA Haz Mat Survey PROJECT NO.: 67796.001

EMC # L85025-

SAMPLE DATE /21

CLIENT SAMPLE #

DESCRIPTION

REPORTING LIMIT

(%Pb by weight)

%Pb BY WEIGHT

21 04/13 1021 49587 River - Interior Paint, White, Shop Walls 0.013 BRL

22 04/13 1022 49591 River - Interior, Family Room, Blue, Wall 0.011 BRL

23 04/13 1023 49591 River - Interior, Pink, NE Room, Wall 0.011 BRL

24 04/13 1024 49591 River - Interior, White, Walls 0.011 BRL

25 04/13 1025 49591 River – Exterior, Green, Siding 0.010 BRL

26 04/13 1026 49591 River – Exterior, White, Trim 0.020 BRL

27 04/13 1027 49591 River – Interior, Mother-in-Law, Green, Walls 0.032 BRL ^ = Dilution Factor Changed * = Excessive Substrate May Bias Sample Results BRL = Below Reportable Limits # = Very Small Amount Of Sample Submitted, May Affect Result This report applies to the standards or procedures identified and to the samples tested only. The test results are not necessarily indicative or representative of the qualities of the lot from which the sample was taken or of apparently identical or similar products, nor do they represent an ongoing quality assurance program unless so noted. Unless otherwise noted, all quality control analyses for the samples noted above were within acceptable limits. Where it is noted that a sample with excessive substrate was submitted for laboratory analysis, such analysis may be biased. The lead content of such sample may, in actuality, be greater than reported. EMC makes no warranty, express or implied, as to the accuracy of the analysis of samples noted to have been submitted with excessive substrate. Resampling is recommended in such situations to verify original laboratory results. EMC Labs, Inc. (ID 101586) is accredited by the AIHA Laboratory Accreditation Programs, LLC (AIHA-LAP, LLC) in the Environmental Lead accreditation program(s) for Paint, Settled Dust by Wipe, Soil and Airborne Dust Fields of Testing as documented by the Scope of Accreditation Certificate and associated Scope. AIHA-LAP, LLC accreditation complies with the ISO/IEC Standard 17025:2005. requirements. These reports are for the exclusive use of the addressed client and are rendered upon the condition that they will not be reproduced wholly or in part for advertising or other purposes over our signature or in connection with our name without special written permission. Samples not destroyed in testing are retained a maximum of sixty (60) days.

EMC LABS, INC.

9830 South 51st Street, Suite B-109 / PHOENIX, ARIZONA 85044 / 480-940-5294 or 800-362-3373 / FAX 480-893-1726

[email protected]

ANALYST: QA COORDINATOR: Jason Thompson Kurt Kettler

Ver. 11/30/08 Rev. 7/15/19

Page 5 of 5

LEAD (Pb) IN PAINT CHIP SAMPLES EMC SOP METHOD #L01/1 EPA SW-846 METHOD 7420

EMC LAB #: L85025 DATE RECEIVED: 04/20/21

CLIENT: PBS Engineering & Environmental

REPORT DATE: 04/21/21

DATE OF ANALYSIS: 04/21/21

CLIENT ADDRESS: 400 Bradley Blvd, Ste 106 Richland, WA 99352

P.O. NO.:

PROJECT NAME: CTUIR FEMA Haz Mat Survey PROJECT NO.: 67796.001

EMC # L85025-

SAMPLE DATE /21

CLIENT SAMPLE #

DESCRIPTION

REPORTING LIMIT

(%Pb by weight)

%Pb BY WEIGHT

28 04/13 1028 49591 River – Exterior, Mother-in-Law, Blue, Door 0.105 BRL#

29 04/13 1029 49591 River – Interior, Mother-in-Law, White, Walls 0.011 BRL

30 04/13 1030 49591 River – Interior, Mother-in-Law, Gray, Walls 0.010 BRL

31 04/13 1031 49591 River – Interior, Mother-in-Law, Beige, Walls 0.010 BRL ^ = Dilution Factor Changed * = Excessive Substrate May Bias Sample Results BRL = Below Reportable Limits # = Very Small Amount Of Sample Submitted, May Affect Result This report applies to the standards or procedures identified and to the samples tested only. The test results are not necessarily indicative or representative of the qualities of the lot from which the sample was taken or of apparently identical or similar products, nor do they represent an ongoing quality assurance program unless so noted. Unless otherwise noted, all quality control analyses for the samples noted above were within acceptable limits. Where it is noted that a sample with excessive substrate was submitted for laboratory analysis, such analysis may be biased. The lead content of such sample may, in actuality, be greater than reported. EMC makes no warranty, express or implied, as to the accuracy of the analysis of samples noted to have been submitted with excessive substrate. Resampling is recommended in such situations to verify original laboratory results. EMC Labs, Inc. (ID 101586) is accredited by the AIHA Laboratory Accreditation Programs, LLC (AIHA-LAP, LLC) in the Environmental Lead accreditation program(s) for Paint, Settled Dust by Wipe, Soil and Airborne Dust Fields of Testing as documented by the Scope of Accreditation Certificate and associated Scope. AIHA-LAP, LLC accreditation complies with the ISO/IEC Standard 17025:2005. requirements. These reports are for the exclusive use of the addressed client and are rendered upon the condition that they will not be reproduced wholly or in part for advertising or other purposes over our signature or in connection with our name without special written permission. Samples not destroyed in testing are retained a maximum of sixty (60) days.

EMC LABS, INC.

9830 South 51st Street, Suite B-109 / PHOENIX, ARIZONA 85044 / 480-940-5294 or 800-362-3373 / FAX 480-893-1726

[email protected]

ANALYST: QA COORDINATOR: Jason Thompson Kurt Kettler

Ver. 11/30/08 Rev. 7/15/19

Page 1 of 4

LEAD (Pb) IN PAINT CHIP SAMPLES EMC SOP METHOD #L01/1 EPA SW-846 METHOD 7420

EMC LAB #: L85023 DATE RECEIVED: 04/20/21

CLIENT: PBS Engineering & Environmental

REPORT DATE: 04/21/21

DATE OF ANALYSIS: 04/21/21

CLIENT ADDRESS: 400 Bradley Blvd, Ste 106 Richland, WA 99352

P.O. NO.:

PROJECT NAME: CTUIR FEMA Hazmat PROJECT NO.: 67796.001

EMC # L85023-

SAMPLE DATE /21

CLIENT SAMPLE #

DESCRIPTION

REPORTING LIMIT

(%Pb by weight)

%Pb BY WEIGHT

1 04/14 1032 49683 River-Beige, Bathroom, Walls 0.020 0.031

2 04/14 1033 49683 River-White, Interior, Walls 0.025 BRL

3 04/14 1034 49683 River-Gray, Laundry Rm. Walls 0.043 BRL

4 04/14 1035 49683 River-Off White, Shop, Door/Trim 0.15 BRL

5 04/14 1036 52153 Cayuse-Lt. Purple, W. Bathroom, Wall 0.014 BRL

6 04/14 1037 52153 Cayuse-Off White, NW Bedroom, Wall 0.030 BRL

7 04/14 1038 52153 Cayuse-Yellow, Family Room, Wall 0.010 BRL ^ = Dilution Factor Changed * = Excessive Substrate May Bias Sample Results BRL = Below Reportable Limits # = Very Small Amount Of Sample Submitted, May Affect Result This report applies to the standards or procedures identified and to the samples tested only. The test results are not necessarily indicative or representative of the qualities of the lot from which the sample was taken or of apparently identical or similar products, nor do they represent an ongoing quality assurance program unless so noted. Unless otherwise noted, all quality control analyses for the samples noted above were within acceptable limits. Where it is noted that a sample with excessive substrate was submitted for laboratory analysis, such analysis may be biased. The lead content of such sample may, in actuality, be greater than reported. EMC makes no warranty, express or implied, as to the accuracy of the analysis of samples noted to have been submitted with excessive substrate. Resampling is recommended in such situations to verify original laboratory results. EMC Labs, Inc. (ID 101586) is accredited by the AIHA Laboratory Accreditation Programs, LLC (AIHA-LAP, LLC) in the Environmental Lead accreditation program(s) for Paint, Settled Dust by Wipe, Soil and Airborne Dust Fields of Testing as documented by the Scope of Accreditation Certificate and associated Scope. AIHA-LAP, LLC accreditation complies with the ISO/IEC Standard 17025:2005. requirements. These reports are for the exclusive use of the addressed client and are rendered upon the condition that they will not be reproduced wholly or in part for advertising or other purposes over our signature or in connection with our name without special written permission. Samples not destroyed in testing are retained a maximum of sixty (60) days.

EMC LABS, INC.

9830 South 51st Street, Suite B-109 / PHOENIX, ARIZONA 85044 / 480-940-5294 or 800-362-3373 / FAX 480-893-1726

[email protected]

ANALYST: QA COORDINATOR: Jason Thompson Kurt Kettler

Ver. 11/30/08 Rev. 7/15/19

Page 2 of 4

LEAD (Pb) IN PAINT CHIP SAMPLES EMC SOP METHOD #L01/1 EPA SW-846 METHOD 7420

EMC LAB #: L85023 DATE RECEIVED: 04/20/21

CLIENT: PBS Engineering & Environmental

REPORT DATE: 04/21/21

DATE OF ANALYSIS: 04/21/21

CLIENT ADDRESS: 400 Bradley Blvd, Ste 106 Richland, WA 99352

P.O. NO.:

PROJECT NAME: CTUIR FEMA Hazmat PROJECT NO.: 67796.001

EMC # L85023-

SAMPLE DATE /21

CLIENT SAMPLE #

DESCRIPTION

REPORTING LIMIT

(%Pb by weight)

%Pb BY WEIGHT

8 04/14 1039 52153 Cayuse--Gray, NE Hall, Wall 0.011 BRL

9 04/14 1040 52153 Cayuse-Lt. Green, E. Bathroom, Wall 0.010 BRL

10 04/14 1041 52153 Cayuse-Beige, NE Int., Wall 0.019 BRL

11 04/14 1042 52153 Cayuse-Burnt Orange, E. Int., Wall 0.035 BRL

12 04/14 1043 52153 Cayuse-Lt. Blue, SW Living Rm., Wall 0.019 BRL

13 04/14 1044 52153 Cayuse-White, Main Int., Walls 0.014 BRL

14 04/14 1045 52153 Cayuse-Mint Green, Exterior, Paneling 0.013 BRL ^ = Dilution Factor Changed * = Excessive Substrate May Bias Sample Results BRL = Below Reportable Limits # = Very Small Amount Of Sample Submitted, May Affect Result This report applies to the standards or procedures identified and to the samples tested only. The test results are not necessarily indicative or representative of the qualities of the lot from which the sample was taken or of apparently identical or similar products, nor do they represent an ongoing quality assurance program unless so noted. Unless otherwise noted, all quality control analyses for the samples noted above were within acceptable limits. Where it is noted that a sample with excessive substrate was submitted for laboratory analysis, such analysis may be biased. The lead content of such sample may, in actuality, be greater than reported. EMC makes no warranty, express or implied, as to the accuracy of the analysis of samples noted to have been submitted with excessive substrate. Resampling is recommended in such situations to verify original laboratory results. EMC Labs, Inc. (ID 101586) is accredited by the AIHA Laboratory Accreditation Programs, LLC (AIHA-LAP, LLC) in the Environmental Lead accreditation program(s) for Paint, Settled Dust by Wipe, Soil and Airborne Dust Fields of Testing as documented by the Scope of Accreditation Certificate and associated Scope. AIHA-LAP, LLC accreditation complies with the ISO/IEC Standard 17025:2005. requirements. These reports are for the exclusive use of the addressed client and are rendered upon the condition that they will not be reproduced wholly or in part for advertising or other purposes over our signature or in connection with our name without special written permission. Samples not destroyed in testing are retained a maximum of sixty (60) days.

EMC LABS, INC.

9830 South 51st Street, Suite B-109 / PHOENIX, ARIZONA 85044 / 480-940-5294 or 800-362-3373 / FAX 480-893-1726

[email protected]

ANALYST: QA COORDINATOR: Jason Thompson Kurt Kettler

Ver. 11/30/08 Rev. 7/15/19

Page 3 of 4

LEAD (Pb) IN PAINT CHIP SAMPLES EMC SOP METHOD #L01/1 EPA SW-846 METHOD 7420

EMC LAB #: L85023 DATE RECEIVED: 04/20/21

CLIENT: PBS Engineering & Environmental

REPORT DATE: 04/21/21

DATE OF ANALYSIS: 04/21/21

CLIENT ADDRESS: 400 Bradley Blvd, Ste 106 Richland, WA 99352

P.O. NO.:

PROJECT NAME: CTUIR FEMA Hazmat PROJECT NO.: 67796.001

EMC # L85023-

SAMPLE DATE /21

CLIENT SAMPLE #

DESCRIPTION

REPORTING LIMIT

(%Pb by weight)

%Pb BY WEIGHT

15 04/14 1046 52153 Cayuse-Forest Green, Exterior, Trim 0.030 BRL

16 04/14 1047 52153 Cayuse-Gray/Green, Exterior Shop, Panel 0.015 BRL

17 04/14 1048 52153 Cayuse-White, Shop Interior, Walls 0.012 BRL

18 04/15 1049 52277 Cayuse-Lt. Green, Shop, Panel Ext./Int. 0.10 1.94^

19 04/15 1050 52277 Cayuse-Orange, Shop Trailer, Int. Walls 0.32 5.56^

20 04/15 1051 52277 Cayuse-Green, Main Ext., Green Trim 0.029 BRL

21 04/15 1052 52277 Cayuse-Brown, Main Ext. Trim 0.037 BRL ^ = Dilution Factor Changed * = Excessive Substrate May Bias Sample Results BRL = Below Reportable Limits # = Very Small Amount Of Sample Submitted, May Affect Result This report applies to the standards or procedures identified and to the samples tested only. The test results are not necessarily indicative or representative of the qualities of the lot from which the sample was taken or of apparently identical or similar products, nor do they represent an ongoing quality assurance program unless so noted. Unless otherwise noted, all quality control analyses for the samples noted above were within acceptable limits. Where it is noted that a sample with excessive substrate was submitted for laboratory analysis, such analysis may be biased. The lead content of such sample may, in actuality, be greater than reported. EMC makes no warranty, express or implied, as to the accuracy of the analysis of samples noted to have been submitted with excessive substrate. Resampling is recommended in such situations to verify original laboratory results. EMC Labs, Inc. (ID 101586) is accredited by the AIHA Laboratory Accreditation Programs, LLC (AIHA-LAP, LLC) in the Environmental Lead accreditation program(s) for Paint, Settled Dust by Wipe, Soil and Airborne Dust Fields of Testing as documented by the Scope of Accreditation Certificate and associated Scope. AIHA-LAP, LLC accreditation complies with the ISO/IEC Standard 17025:2005. requirements. These reports are for the exclusive use of the addressed client and are rendered upon the condition that they will not be reproduced wholly or in part for advertising or other purposes over our signature or in connection with our name without special written permission. Samples not destroyed in testing are retained a maximum of sixty (60) days.

EMC LABS, INC.

9830 South 51st Street, Suite B-109 / PHOENIX, ARIZONA 85044 / 480-940-5294 or 800-362-3373 / FAX 480-893-1726

[email protected]

ANALYST: QA COORDINATOR: Jason Thompson Kurt Kettler

Ver. 11/30/08 Rev. 7/15/19

Page 4 of 4

LEAD (Pb) IN PAINT CHIP SAMPLES EMC SOP METHOD #L01/1 EPA SW-846 METHOD 7420

EMC LAB #: L85023 DATE RECEIVED: 04/20/21

CLIENT: PBS Engineering & Environmental

REPORT DATE: 04/21/21

DATE OF ANALYSIS: 04/21/21

CLIENT ADDRESS: 400 Bradley Blvd, Ste 106 Richland, WA 99352

P.O. NO.:

PROJECT NAME: CTUIR FEMA Hazmat PROJECT NO.: 67796.001

EMC # L85023-

SAMPLE DATE /21

CLIENT SAMPLE #

DESCRIPTION

REPORTING LIMIT

(%Pb by weight)

%Pb BY WEIGHT

22 04/15 1053 53017 Cayuse-White, N. Studio, Int. Walls 0.010 BRL

23 04/15 1054 53017 Cayuse-White, E. Studio, Int. Walls 0.026 BRL

24 04/15 1055 53017 Cayuse-Brown, Pumphouse, Ext. Panel 0.010 BRL

25 04/15 1056 53017 Cayuse-White, Shop, Ext. Door 0.039 BRL

26 04/15 1057 53017 Cayuse-White, Main Interior, Walls 0.025 BRL ^ = Dilution Factor Changed * = Excessive Substrate May Bias Sample Results BRL = Below Reportable Limits # = Very Small Amount Of Sample Submitted, May Affect Result This report applies to the standards or procedures identified and to the samples tested only. The test results are not necessarily indicative or representative of the qualities of the lot from which the sample was taken or of apparently identical or similar products, nor do they represent an ongoing quality assurance program unless so noted. Unless otherwise noted, all quality control analyses for the samples noted above were within acceptable limits. Where it is noted that a sample with excessive substrate was submitted for laboratory analysis, such analysis may be biased. The lead content of such sample may, in actuality, be greater than reported. EMC makes no warranty, express or implied, as to the accuracy of the analysis of samples noted to have been submitted with excessive substrate. Resampling is recommended in such situations to verify original laboratory results. EMC Labs, Inc. (ID 101586) is accredited by the AIHA Laboratory Accreditation Programs, LLC (AIHA-LAP, LLC) in the Environmental Lead accreditation program(s) for Paint, Settled Dust by Wipe, Soil and Airborne Dust Fields of Testing as documented by the Scope of Accreditation Certificate and associated Scope. AIHA-LAP, LLC accreditation complies with the ISO/IEC Standard 17025:2005. requirements. These reports are for the exclusive use of the addressed client and are rendered upon the condition that they will not be reproduced wholly or in part for advertising or other purposes over our signature or in connection with our name without special written permission. Samples not destroyed in testing are retained a maximum of sixty (60) days.