Pre and post treatment of water
-
Upload
prudhvi-raj -
Category
Documents
-
view
401 -
download
2
description
Transcript of Pre and post treatment of water
1
Welcome to Training Programme
Water Treatment Pre Treatment & Demineralization
1
JSW Energy Ltd
2
WATER
JSW Energy Ltd
Molecular Formula – H2O Properties: Available in three different states. High heat storage capacity. High latent heat of evaporation. Universal solvent. Easy to handle.
Water is used in power plants for steam generation
& as cooling water
3
JSW Energy Ltd
SOURCES
Surface Water – Lakes, River, Dam.
Ground Water – Wells, Deep Springs.
Sea Water.
4
JSW Energy Ltd
IMPURITIES Insoluble Silt, Mud, Colloidal matter, Organics,
Microbes, Algae. Soluble Organic - Natural organics Inorganic Cations – Ca, Mg, Na, K, Fe, Al, As, Anions – HCO3, CO3/ Cl, SO4, NO3, PO4, F,
SiO2 Gases - Oxygen, Carbon di oxide, Ammonia etcIf impurities are not removed from water they
cause Scale formation, fouling & corrosion in user
systems
5
JSW Energy Ltd
Water in Nature Contains Suspended impurities – Silt, Mud, Organic
debris, Colloidal matter, etc.
Organic matter – Bacteria, Algae, Dissolved Organic matter.
Dissolved Matter – Mainly Salts of Alkali and Alkaline earth metals.
6
JSW Energy Ltd
Raw Water TreatmentRaw water treatment is divided in two main
partsExternal Treatment – Commonly known as Pre-Treatment. Used to remove un-dissolved as well as
dissolved impurities from water. Treatment choice varies with water
characteristics and application.Internal Treatment – Commonly known as chemical treatment. Main objective to eliminate problems likes
scaling, corrosion, microbial growth. Treatment choice varies with make-up water
quality, equipment used & economy.
7
JSW Energy Ltd
Organic Matter – Chlorination. Suspended Matter – Coagulation /
Flocculation Dissolved Matter – R.O, Ion Exchange Steps 1 and 2 Comes Under Pre
Treatment. Pre Treatment is done to meet the
process and drinking water requirement and also to maintain the plant cooling water system and the DM Plant.
Recommended Treatments
8
JSW Energy Ltd
The process of removing suspended matter.- Coagulation- Flocculation- Sedimentation
Coagulation is the process of destabilisation by charge neutralisation.
Finely divided particles suspended in surface water repel each other because their surfaces are predominantly negatively charged. Once neutralised, particles no longer repel each other and can be brought together. This is achieved by adding inorganic salts of aluminium or iron which neutralise the charge on the turbidity particle.
Eg. Alum.
CLARIFICATION
9
JSW Energy Ltd
Flocculation is the process of bringing together the destabilised or coagulated particles to form a larger agglomeration or floc.
Coagulation and flocculation are aided and enhanced by Coagulant / Flocculant aids like polyelectrolytes.These are long chain polymer molecules with higher charge density. They help form larger floc which settles faster.Unlike inorganic coagulants they do not decrease the pH of the treated water nor increase the TDS.Sedimentation refers to the physical removal from suspension or settling that occurs once the particles are coagulated and flocculated.
10
JSW Energy Ltd
CoagulationFinely divided suspended particles in water repel each other because most of the particles are negatively charged .The coagulants neutralize the charge and also hydrolyze to form insoluble precipitates. pH plays animportant role
Accomplished by inorganic salts of Aluminium and Iron or by organic polymersAl2(SO4)3 + 6NaHCO3 =2 Al(OH)3+3Na2SO4+6CO2Best coagulation in pH range 6 - 7
11
JSW Energy Ltd
Inorganic CoagulantsAl2(SO4)3 + 6NaHCO3 = 2Al(OH)3 ¯ + 3Na2SO4 +
6CO2pH 6-7Fe2(SO4)3 + 6NaHCO3 = 2Fe(OH)3 ¯ + 3Na2SO4
+ 6CO2pH 5 -11Na2Al2O4 + 4H2O = 2Al(OH)3 ¯ + 2NaOHpH 7-9
1 ppm of alum adds0.45 ppm of sulfate ion as CaCO3
12
JSW Energy Ltd
PolyelectrolyteThey are water soluble organic polymers used
in Clarification.Low molecular weight(<500000) polymers used
for primary CoagulationHigh molecular weight polymers are used for flocculation
13
JSW Energy Ltd
Types of poly-electrolytes
Anionic: ionize in water to form negatively charged sites along the polymer chain. It is a copolymer of acrylamide and acrylic acidCationic: ionize in water to form positively Charged sites along the polymer chain. It is a copolymer of acrylamide and acrylic acid Nonionic: ionize in water to form slightly negatively charged sites along the polymer chain.It is basically polyacrylamide
14
JSW Energy Ltd
Chlorine, Sodium hypochlorite Ozone etc. are some of the chemicals used for Oxidation
Cl2 + H2O = HOCl + H+ + Cl-
Ozone is a powerful oxidizing agent but requires on site generation equipment
15
JSW Energy Ltd
The Three processes happening in a clarification equipment are
- Rapid mix for coagulation- Moderate mixing for flocculation and- Floc and water separation.
The most common design is the upflow clarifier where the water flows up while the floc settles.The two types are
- Sludge blanket type and- Solids contact type
Both utilise part of the settled floc to enhance sedimentation
Clarification
16
JSW Energy LtdRemoves bulk of turbidity & sediment. The particles with a settling velocity exceeding the upward velocity of the fluid settle out and are separated
STOKES LAW
Vs = g(ρs –ρl)d2
------------------
18μVs is terminal settling velocity m/sg is acceleration due to gravity m/s2
d is particle diameter m ρs, ρl density of particle, liquid,Kg/m3
μ is liquid viscosity Pa.S
17
JSW Energy Ltd
Clariflocculator "Solids-contact" refers to units in which large
volumes of sludge are circulated internally. The term also describes the sludge blanket unit and simply means that prior to and during sedimentation the chemically treated water contacts previously coagulated solids.
18
JSW Energy Ltd
Clarifier JSW Steel Ltd
19
JSW Energy Ltd
The efficiency of coagulation – flocculation is increased by repeated soilids contact.
The sludge formed in the Process is utilized to contactthe coagulated –flocculated water and increase the probability of collisions resulting In better flocculation.High rate solids contact clarifiers work on this principle
20
JSW Energy LtdSolids contact Clarifier
21
JSW Energy Ltd
Filtration Used to remove any remnants from clarification process brings down turbidity from 10-20 NTU to 0.5 – 2 NTU.If raw water has less turbidity, directly filtration can be applied.It is a separation process where in solid liquid mixture is passed through porous media which retains solids and allows liquid to pass through.During filtration the retained solids gradually build up and block the interstices of the filter media and cause head loss.
22
JSW Energy Ltd
Gravity filters – Pressure filters
Down flow filters – Up-flow filters
Automatic gravity filters
Filter washing gravity filters
Pre coat filters
Self cleaning filters
TYPES OF FILTERS
23
JSW Energy Ltd
Gravity Sand filter
24
JSW Energy Ltd
Pressure sand filter
25
JSW Energy Ltd
The filter needs to be back washed :
Once the head loss reaches a preset value
The treated water turbidity deviates from the preset value
Back wash is performed using
1.Air and Water simultaneously 2.Air and water in succession
26
JSW Energy Ltd
The different types of filter media used are
Quartz sand Anthracite Dual media of sand and Anthracite / garnet Multi media of sand, anthracite Garnet, Granular activated carbon (GAC)
Typical filter media is 15 -30 inch deep bed. Dual media filters allow high filtration rates, requireLess back wash water than stand alone filters GAC additionally removes organics and free chlorine
FILTERMEDIA
27
JSW Energy Ltd
DEMINERALIZATION
The process of removing the dissolved solids from Water is known as Demineralization
This is accomplished at JSW Energy by using Ion Exchange Process
28
JSW Energy LtdDM Plant Flow Diagram
DMFDegas blower
Degas waterStorage
Tank
Raw water tank
SAC
DM STORAGETankSBA
Mixed Bed
UF STORAGETank
UF
29
JSW Energy Ltd
Dual Media Filter
Carbon steel vessel containing Sand & AnthraciteCapacity :45 m3/hrAnthracite Qty : 1.64m3, 0.508 m depthSize of Anthracite : 0.9 – 1.0 mmSand Qty :2.07 m3, 0.405 m depth Size of sand : 0.45 – 0.55 mmTurbidity Inlet water : <20 NTUTurbidity Outlet water : <2 NTU
30
JSW Energy LtdIon Exchange Resins
Made by co polymerization of Styrene cross linked with Di-vinyl Benzene. Ion exchange resins exchange one ion for another, hold it temporarily and release it to a regenerant solution.
New forms of resins with acrylic structures are also available with more resistance to organic fouling
In addition to plastic matrix ion exchange resin has ionizable functional groups. This contains one mobile and one immobile Radical. Mobile radical is exchanged
31
JSW Energy Ltd
Strong Acid Cation Resin (R-SO3.H)
SAC has sulfonic acid (HSO3) functional groupConverts neutral salts into respective acids
Ca 2(HCO3) Ca 2H2CO3Mg SO4 + 2RSO3.H = 2RSO3. Mg + H2SO42Na 2Cl 2Na 2HCl
The exchange reaction is reversible. When capacity Is exhausted the resin is regenerated with excess quantity of mineral acid
32
JSW Energy Ltd
Strong acid Cation Resin
33
JSW Energy Ltd
SAC is a rubber lined carbon steel vessel with inlet distributor, regenerant distributor, ion exchange resin free board space and resin retaining under drain system
Resin is retained using strainers which allow only water to flow and prevent resin
The volume of resin employed depends up on capacity of resin and salanity to be removed
Selectivity for cation exchangeCa > Mg > Na
34
JSW Energy Ltd
ION EXCHANGE VESSEL INTERNALS
35
JSW Energy Ltd
STRAINERS
36
JSW Energy Ltd
Strong acid cation is regenerated when
1.Designed quantity of water is processed OR2.Sodium content in outlet water is more than design usually >1 ppm OR3.Conductivity comparator reading crosses stipulated value
37
JSW Energy Ltd
Regeneration Co – flow Counter flow
Service Regeneration Service Regeneration
Counter flow results in
High quality out put, better regeneration efficiency
Requires down flow water to keep resin bed intact
38
JSW Energy Ltd
Hydrochloric acid Regeneration 4 – 5% HCl
Sulphuric acid Regeneration H2SO4
Step 1 : 1.5 – 2 %
Step 2 : 3 %
To avoid Calcium Sulphate precipitation
Regeneration
39
JSW Energy Ltd
Degasser Tower
Water Inlet
Air Inlet
Air Vent
Water Storage
Packing
40
JSW Energy Ltd
De carbonator works on the principle of Henry’s law
Solubility of any gas in liquid is directly proportional to the partial pressure of gas at the liquid surface C total = K P
C total : total concentration of gas in solution
P : Partial pressure of gas above solution
K : constant
41
JSW Energy Ltd
Hence a dissolved gas can be removed from solution By lowering the partial pressure of the gas above solution
This can be done by
1. Vacuum is applied over the system and unwanted gas is vented
2. A new gas is introduced and unwanted gas is vented
42
JSW Energy Ltd
Strong Base Anion
Strong base anion has quarternary ammonium Functional group and is used in hydroxide (OH-) form CH3 l (R – N – CH3)+. OH-
l CH3
43
JSW Energy Ltd
In hydroxide form SBA can remove all anions commonly encountered
H2SO4 SO4
2HCl 2Cl 2H2SiO3 + 2R.OH = 2R. 2HSiO3 + 2H2O2H2CO3 2HCO3
The reactions are reversible and once exhausted The resin can be regenerated with sodium hydroxide to return to hydroxide formThe selectivity for anion exchange SO4 > Cl > HSiO3
44
JSW Energy Ltd
Treated water quality parameters for SBA
pH 7.5 to 8.5
Conductivity < 6.0 μ s/cm
Silica < 0.1 ppm
45
JSW Energy Ltd
Strong base anion is regenerated
1.When designed quantity of water is processed OR2.Silica content in treated water goes beyond limits OR 3.Conductivity of treated water increases beyond limits& pH of treated water is lower then limits
Regeneration is carried out using 4% Sodium hydroxide
46
JSW Energy Ltd
MIXED BED
As the name suggests it consists of both Cation and Anion Resins. This is a polishing unit and is the last stage of Demineralization process to get final qualityDM Water. The two resins are in thoroughly mixed state in service condition and are separated for regeneration using Back washAfter back wash Cation resin settles at the bottomand Anion resin remains at top due to density differenceBlocking flow arrangements are designed to prevent entry of regenerant chemicals into other resin duringregeneration
47
JSW Energy Ltd
Treated water quality after Mixed Bed
pH 6.5 to 7.2
Conductivity <0.1 μ s/cm
Silica < 0.02 ppm
48
JSW Energy Ltd
Mixed bed is regenerated
1.When designed quantity of water is processed
OR
2.Silica content in treated water goes beyond limits
OR
3.Conductivity of treated water increases beyond limits
49
JSW Energy LtdULTRA FILTRATION
Ultra filtration is a membrane process in which higher molecular weight solutes are concentrated from feed streamIn JSW Energy it is employed to remove colloidal Silica which can not be removed in Ion exchange process. Colloidal Silica removal efficiency > 95%
Ultra filtration membranes are hollow fiber membranes made of Polysulphone (PS)Polyethersulphone (PES)Polyvinylidenefluoride (PVDF)
50
JSW Energy Ltd
UF Hollow Fiber Membrane
51
JSW Energy Ltd
The filtration system is inside out cross- flow filtration
Fast flush : In this water will flow in the same direction as in service with higher flow rate membraneGets pressurized and adhered material gets dislodged
Back flush: In this water flows in opposite direction toService cycle. This takes away the remaining dirt afterFast flush
52
JSW Energy Ltd
DMT
Fast flush pump
Feed pump
Pre-filter
UF MODULE
Back flush pump UFT
UF PERMEATE
Reject To CW Forebay
To Neutralizing pit
Cleaning tank
UF SCHEMATIC
53
JSW Energy Ltd
Thank You