VG 425 211 CA Stainless steel Width 15" (38 cm) Natural gas. For conversion to LP gas, LP kit (part #427789) must be ordered. Installation accessories In combination of several Vario cooktops or VL 414 downdraft, connecting strips must be used. Choose respective VA 420 strip from one of the below, depending on type of installation. VA 420 010 Connection strip for surface-mount installation without appliance cover. VA 420 011 Connection strip for surface-mount installation with appliance cover. VA 420 000 Connection strip for flush installation without appliance cover. VA 420 001 Connection strip for flush installation with appliance cover. VA 440 010 Stainless steel cover with mounting strip VA 450 400 Stainless steel adjustment strip, width 15". Necessary accessory in a combi- nation of 15" Varios with at least one appliance cover to compensate for the appliance depth. Vario 400 series gas cooktop VG 425 Two two-ring burners up to 13,600 BTU. Full electronic power regulation on 12 levels. Full electronic gas valves for precise and reproducible power regulation. Automatic fast ignition, electronic flame monitoring with automatic re-ignition. Simmer function for cooking on a very low output level Solid smooth-surface cast-iron pan supports Solid stainless steel control knobs Precision-crafted ⅛-inch stainless steel frame For surface-mount installation with a visible edge or for flush installation Can be perfectly combined with other Vario 400 series products Cooking zones 1 two-ring high-output burner (570 – 13,600 BTU), suitable for pots and pans up to a maximum ø 11". 1 two-ring standard-output burners (570 – 6,800 BTU), suitable for pots and pans up to a maximum ø 9 ⁷⁄₁₆". Operation Control knobs with illuminated ring, cooking zone and output level markings. One-handed operation. Full electronic control in 12 output levels for exact power level regulation plus simmer function. Automatic fast ignition. Features Simmer function (570 BTU). Cast-iron pan support with flat, continuous pot surface. Brass burner rings. Equipped for natural gas. For conversion to LP gas, LP kit (part #427789) must be ordered. Safety Electronic flame monitoring with automatic re-ignition. Residual heat indication. Safety shut-off. Planning notes Depending on the type of installation — surface-/ or flush-mounted, with or without cover — the specific location of the control knob positions may vary. When using the appliance cover VA 440 or adjustment strip VA 450 additional space for cut-out depth needs to be considered. In a combination of Vario cooktops with at least one appliance cover, the adjustment strip VA 450 is required. In a combination of several Vario 400 series cooktops a connection strip must be used. Depending on the type of installation — surface-/ or flush-mounted, with or without cover — the respective VA 420 connecting strip must be used. For flush installation the edge height in the cut-out needs to be at least ½" and for surface-mount ⅜". Ensure a continuous cut surface of 90°. The weight capacity and stability, especially in case of thin countertops, must be supported using suitable substructures. Take the appliance weight and additional loads into account. Flush installation is possible in countertops made of stone, synthetics or solid wood. Heat resistance and watertight sealing of the edges must be observed. For other materials, please consult with your countertop manufacturer. The groove must be continuous and even, so that uniform placing of the appliance on the gasket is ensured. Do not use discontinuous lining. The joint width may vary due to size tolerances of the combinations and of the countertop cut-out. If installing several Vario products in individual cut-outs allow for a minimum distance of 2" between the cooktops. Control knobs to be integrated in the base cabinet at drawer level. Panel thickness ⅝" – 1". The adjacent drawing “Installation of the control knob” must be observed, if the panel is more than 1" thick. There must be a recess at the rear for proper electronic knob installation. Plan for an electrical connection (the appliance is not operable without power supply). Air intake from above. No intermediate shelf required. The rear panel must consist of a non- flammable material. Wall trims must be resistant to heat. The minimum distance from the side of appliance edge to the wall or furnishing components must be at least 6". When used with VL 414 downdraft ventilation, the air deflector AA 414 is recommended to ensure maximum performance of the cooktop. Minimum distance between gas cooktop(s) and ventilation hood must be 30". Appliance can be snapped into the countertop from above. Please read additional planning notes on pages 84 – 89. Rating Total rating: 20,500 BTU (6.0 kW). Total Amps: 2 A. 120 V / 60 Hz Connecting cable 55" with plug.

Transcript of Pr ecision-crafted ⅛-inch stainless Panel thickness ⅝ – 1.

VG 425 211 CA Stainless steelWidth 15" (38 cm) Natural gas. For conversion to LP gas, LP kit (part #427789) must be ordered.

Installation accessoriesIn combination of several Vario cooktops or VL 414 downdraft, connecting strips must be used.Choose respective VA 420 strip from one of the below, depending on type of installation.VA 420 010Connection strip for surface-mount installation without appliance cover.VA 420 011Connection strip for surface-mount installation with appliance cover.VA 420 000Connection strip for flush installation without appliance cover.VA 420 001Connection strip for flush installation with appliance cover.VA 440 010Stainless steel cover with mounting stripVA 450 400Stainless steel adjustment strip, width 15". Necessary accessory in a combi-nation of 15" Varios with at least one appliance cover to compensate for the appliance depth.

Vario 400 series gas cooktopVG 425

– Two two-ring burners up to 13,600 BTU.

– Full electronic power regulation on 12 levels.

– Full electronic gas valves for precise and reproducible power regulation.

– Automatic fast ignition, electronic flame monitoring with automatic re-ignition.

– Simmer function for cooking on a very low output level

– Solid smooth-surface cast-iron pan supports

– Solid stainless steel control knobs – �Precision-crafted�⅛-inch�stainless�

steel frame – For surface-mount installation with

a visible edge or for flush installation

– Can be perfectly combined with other Vario 400 series products

Cooking zones1 two-ring high-output burner (570 – 13,600 BTU), suitable for pots and pans up to a maximum ø 11".1 two-ring standard-output burners (570 – 6,800 BTU), suitable for pots and�pans�up�to�a�maximum�ø�9�⁷⁄₁₆".

OperationControl knobs with illuminated ring, cooking zone and output level markings.One-handed operation.Full electronic control in 12 output levels for exact power level regulation plus simmer function.Automatic fast ignition.

FeaturesSimmer function (570 BTU). Cast-iron pan support with flat, continuous pot surface.Brass burner rings.Equipped for natural gas. For conversion to LP gas, LP kit (part #427789) must be ordered.

SafetyElectronic flame monitoring with automatic re-ignition.Residual heat indication.Safety shut-off.

Planning notesDepending on the type of installation — surface-/ or flush-mounted, with or without cover — the specific location of the control knob positions may vary.When using the appliance cover VA 440 or adjustment strip VA 450 additional space for cut-out depth needs to be considered.In a combination of Vario cooktops with at least one appliance cover, the adjustment strip VA 450 is required.In a combination of several Vario 400 series cooktops a connection strip must be used.Depending on the type of installation — surface-/ or flush-mounted, with or without cover — the respective VA 420 connecting strip must be used.For flush installation the edge height in the cut-out needs to be at least ½" and�for�surface-mount�⅜".�Ensure�a�continuous cut surface of 90°.The weight capacity and stability,

especially in case of thin countertops, must be supported using suitable substructures. Take the appliance weight and additional loads into account.Flush installation is possible in countertops made of stone, synthetics or solid wood. Heat resistance and watertight sealing of the edges must be observed. For other materials, please consult with your countertop manufacturer.The groove must be continuous and even, so that uniform placing of the appliance on the gasket is ensured. Do not use discontinuous lining.The joint width may vary due to size tolerances of the combinations and of the countertop cut-out.If installing several Vario products in individual cut-outs allow for a minimum distance of 2" between the cooktops.Control knobs to be integrated in the base cabinet at drawer level.Panel�thickness�⅝"�–�1".The adjacent drawing “Installation of the control knob” must be observed, if the panel is more than 1" thick. There must be a recess at the rear for proper electronic knob installation.Plan for an electrical connection (the appliance is not operable without power supply).Air intake from above.No intermediate shelf required.The rear panel must consist of a non-flammable material. Wall trims must be resistant to heat.The minimum distance from the side of appliance edge to the wall or furnishing components must be at least 6".When used with VL 414 downdraft ventilation, the air deflector AA 414 is recommended to ensure maximum performance of the cooktop.Minimum distance between gas cooktop(s) and ventilation hood must be 30".Appliance can be snapped into the countertop from above.

Please read additional planning notes on pages 84 – 89.

RatingTotal rating: 20,500 BTU (6.0 kW).Total Amps: 2 A.120 V / 60 HzConnecting cable 55" with plug.

Surface-mount Installation Flush-mount Installation

fill with silicone

Longitudinal section

1/8" (3,5-0,5)

14 3/16"±1/16"(360±2)

1415/16"(380)

15 3/16"+1/16"(386+2)

1/2" (13)

1/2" (13)

1/8" (3+1)

1/8" (3+1)

Longitudinal section

When installing with appliance cover or adjustment strip, pay attention to the deeper cut-out and the front and rear groove width.

Cross-sectionfill with

silicone

1/8" (3.5-0.5)

19 3/8"±1/16"(492±2)

2011/16"+1/16"(526+2)

11/16" (17)

11/16" (17)

1/8" (3+1)

1/8" (3+1)

201/2"(520)

Cross-section

* with appliance cover or adjustment strip. See separate planning notes on page 89. * With appliance cover or adjustment strip. See separate planning notes on page 89.

ø 115/16" (50)

ø 115/16" (50)

min. 3/16" (5)min. 3/16" (5)

Control knob installation, flush installation

4 5/16"-6 9/16" (109-166)

45/16"-6 9/16" (109-166)

2 3/4" (70)

≤ 7/8"(23)

> 7/8"(23)

7/8"(23)

Installation of the control knob; flush-mount installation

ø 115/16" (50)

min. 3/16" (5)min. 3/16" (5)

ø 115/16" (50)

Control knob installation, surface mounting

41/8"-63/8" (105-162)

41/8"-6 3/8" (105-162)

2 3/4" (70)

≤ 7/8"(23)

> 7/8"(23)

7/8"(23)

Installation of the control knob; surface-mount installation

* with appliance cover or spacer batten (observe the front and rear asymmetrical support, see separate notes "Installation with appliance cover/ spacer batten").

View from above

R 3/16"(R 5+1)

R 1/8"(R 3)

14 3/16"±1/16"(360±2)

15 3/16"+1/16"(386+2)

2011/16"+1/16"(526+2)

*211/4"+1/16"(*541+2) 19 3/8"±1/16"

(492±2)*201/4"+1/16"

(*515+2)

View from above

* with appliance cover or adjustment strip (observe front and rear asymmetrical assembly. See separate notes “assembly with appliance cover/adjustment strip” on page 89).

Installation with appliance cover/adjustment strip; surface-mount installation

min. 1"

Installation with appliance cover/adjustment strip; surface-mount installation   

(55)

(515±2)

(5)

(15)

(550)21 ⅝"

2 ³⁄₁₆"

³⁄₁₆"

⁹⁄₁₆"

(25)20 ¼" ±¹⁄₁₆"

Installation with appliance cover/adjustment strip; flush-mount installation

21 ¼" ±¹⁄₁₆"

20 ¼" ±¹⁄₁₆"

Installation with appliance cover/adjustment strip; flush installation

(3.5-0.5)

(3±1)

(546)20 ½"

(55)2 ³⁄₁₆"

⅛" ±¹⁄₃₂"(3±1)

⅛" ±¹⁄₁₆"

min. 1"(25)

(8)⁵⁄₁₆"

(18)¹¹⁄₁₆"(515±2)

(541±2)

⅛"

Numbers indicated inside parenthesis ( ) = mm

90°

* with appliance cover or compensating strip See installation instructions for other installation possibilities.

dia. 2 3/8" (60)

dia. 115/16" (50)

R 1/8"(3)

min. 13/8" (35)

min. 115/16" (50)

min. 41/8" (105)max. 6 3/8" (162)

55" (1.4 m)

193/8"±1/16" (492±2)*20 1/4"+1/16"(515+2)

1415/16"(380) 20 1/2" (520)

*21 1/16" (535)1/8" (3)5 3/16" (131)

14 3/16" ±1/16"(360±2)

3 9/16" (90)

* with appliance cover or compensating strip See installation instructions for other installation possibilities.

90°

R 3/16"+1/16" (5+1)

1/8" (3.5-0.5)

min. 4 5/16" (109)max. 69/16" (166) dia. 23/8" (60)

dia. 115/16" (50)

R 1/8" (3)

min. 13/8" (35)

min. 115/16" (50)

55" (1.4 m)

1415/16"(380)

5 1/4" (134)

201/2" (520)*211/16" (535)

14 3/16" ±1/16"(360±2)

15 3/16" +1/16"(386+2)

1/8" (3)

39/16"(90)

193/8"±1/16" (492±2)

*201/4"+1/16"(515+2)

2011/16"+1/16" (526+2)*215/16"+1/16"(541+2)

Gas connectionGas connection

* 21/16" (53 mm) with appliance cover or adjustment strip.

43/16"(107)

1/2"

11/2"*(38*)