Discover Engineering EfficiencyImprovements delivered inWonderware System Platform 2014
WW HMI SCADA-03
Rob KambachProduct Manager
@InvensysOpsMgmt / #SoftwareRevolution
/Wonderware
/Wonderware HMI
social.invensys.com
© 2013 Invensys. All Rights Reserved. The names, logos, and taglines identifying the products and services of Invensys are proprietary marks of Invensys or its subsidiaries.All third party trademarks and service marks are the proprietary marks of their respective owners.
WW HMI SCADA-03
Rob KambachProduct Manager
/Wonderware
/Group - HMI/Scada/AppServer
Simplicity of loggingCheckboxes in the Alarm Severity list of the IDE determine if Alarms get logged.If Historian is defined no further action is needed.
Slide 3
The Old Process had 17 – 21 error prone steps.Changes in Functionality:• If an alarm is silenced it will still log state changes to the A2ALMDB• New DB A2ALMD to allow easy upgrades DB gets auto created, schema unchanged• Supports domain security and OS based security• Granular, event messages can be turned off
Storage robustnessSupport for- Redundant Engines- Store forward- Redundant Historians- Simplicity, no configuration required
Slide 5
Architecture Historical
Configured for Hist_02
Configured for Hist_01
Auto_Failover
Slide 6
Configured for Hist_02
Double redundant Historical A&E logging, Application Engines and Historians
Global Priority to Severity mapping
Slide 7
One location to change and customizable image…
Default Alarm Border Icons
Best Practices: Alarm signaling in theHMI displays
Severity 1 response time < 5min
Severity 2 response time < 30min
Slide 8
Severity 3 response time < 60min
Severity 4 response time < 120min
Global defined styles for alarm colorsand bordersOne place to change all apps how they represent Alarms
Divided in two categoriesAlarm Border colorsAlarm Fill colors
States:AckedUnackedUnacked RTNSilencedDisabled
Slide 9
Divided in two categoriesAlarm Border colorsAlarm Fill colors
States:AckedUnackedUnacked RTNSilencedDisabled
Alarm Border animationGlobal Icons
Global Styles
Auto Configuration for Field_Attributes or objects
Runtime
Slide 11
Updated Clients- Historical
• Defined with the standard Themes and Styles• Fonts best Practices HMI Standards• Dynamic Filter tabs• Group By functionality
Slide 12
Update Clients -Runtime
• Tabbed filtering• Actual alarm indicators on Tabs• Ack buttons• And styles and themes setup as default
Slide 13
Standards Management
• Reuse of baseline application/components• Application Integrity• Change Management• Installed base management
Slide 15
© Invensys 10/24/2013 Invensys proprietary & confidential
StandardsManagement
2014
Source Galaxy
Export Export
Slide 16X-CHANGE 2013, 21 - 24 APRIL | SUN CITY,SOUTH AFRICA
16
Destination Galaxy
Import Import
2014
• Script Editor• Auto complete function
• Me.• MyContainer.• Scripts
• Multi level Undo-Redo• Line Numbering• Consistent color coding• Syntax Error Indication
Engineering Efficiency
Slide 17
• Script Editor• Auto complete function
• Me.• MyContainer.• Scripts
• Multi level Undo-Redo• Line Numbering• Consistent color coding• Syntax Error Indication