Poznan 08/04/2014 ErP / Labelling regulations ErP & Energy labeling A new age for Thermal Comfort.
-
Upload
cole-larabee -
Category
Documents
-
view
215 -
download
1
Transcript of Poznan 08/04/2014 ErP / Labelling regulations ErP & Energy labeling A new age for Thermal Comfort.
Poznan 08/04/2014 ErP / Labelling regulations
ErP & Energy labeling A new age for Thermal Comfort
Index
Legislation context
ErP/Labeling (summary)
Solid fuel boilers (Lot 15)
Boilers (Lot 1)
Water heaters (Lot 2)
The legislation context
In line with 2020 target
NOT in line with 2020 target
(20/20/20) EU Target on energy consumption not completely reached…
…New / Existing portfolio measures to be adopted/ integrated by countries (with local specificities)
EPBDDirective
2011 2015 2020
Energies
Buildings
ProductsErP /Labelling
Regulation
RES Directive
2001 2006 2009
En. Efficiency Directive
CHP Directive
New En. EfficiencyDirective
EPBDDir. (recast)
EPBDDirective
2011 2015 2020
Energies
Buildings
ProductsErP /Labelling
Regulation
RES Directive
2001 2006 2009
En. Efficiency Directive
CHP Directive
New En. EfficiencyDirective
EPBDDir. (recast)
Incoming…(at the same time for all countries)
Main laws & their upgrades(to be nationally adopted)
EED Dir.
2012/27/EU
ProductsDwellings
The legislation context
Policies for sustainable growth
2002 20122008 2014 2016
Air Quality Dir.
2008/50/EC
Before 2002 Main legislations entered into force
EPBD Dir.
2002/91/ECRES Directive
2009/28/EC
ERP Regulation
&
Labelling
EPBD Recast
2010/31/EC
Energy labels Reqs on new, but also Renovation reqs start to be adopted RES obligation (New) District heating promoted Smart meters & Building Automation Control Systems Local electricity generation (PV, Mchp) Nearly Zero Energy buildings
Istallers qualifications / energy audits Utilities energy savings targets enhanced Energy savings markets (white certificates) development Renewable energies markets (green certificates) ESCO’s promotion Hourly energy tariffs (Smart Grid)
Energy / Quality labels Minimum techn. system performances (New/Retro) – ban of low efficient products (i.e. EWH) RES obligation (New) RES promotion (Retro) – incentive schemes Periodical Sys inspection Emission limits in urban areas PA as example (purchase only HE products)
Services
Main EU laws and related messages
ErP/Labeling - summary
ErP Labeling
Covered products
ENERGY RELATED PRODUCTS (ErP)
(Thermal confort technologies) Boilers, Water heaters, Air conditioners, Heat pumps, storage tanks,
ventilators, circulators… supplied by electricity, gas, oil, solid fuels, liquid fuels etc.
Technologies have been initially grouped in different Lots leading to specific implementing measures
European Regulations
(implementing meausures of 2009/125/eu Directive; valid in the whole European Union, without national adoptons, variations, delays etc.)
What are they?
Binding to bear the EC mark
What they establish?
Minimum energy Performances
+Environmental requirements (emissions, noise,
dismantling etc.) different by technologies
Energy labels (products & packages)
Technical fiches (products & packages)
Technical/promotional materials including
energy performance info
ErP/Labeling - summary
ErP Labeling
European Regulations
(implementing meausures of 2009/125/eu Directive; valid in the whole European Union, without national adoptons, variations, delays etc.)
What are they?
Binding to bear the EC mark
Resp.ties
SUPPLIER (product’s resp on the market)
Places on the market products ErP-compliant;
Places on the market products provided with:
− (product and/or package) Energy labels;
− (product and/or package) Technical fiches;
− Technical advertisements or promotions with info about product/package energy class;
DEALER
The exhibited devices or packages are equipped with the respective labels,
In case it is not expected for the end user to see the exhibited device, this is sold together with the information on energy efficiency;
Technical advertisements or promotions with info about product/package energy class;
Solid fuel boiler ErP/Labeling regulation: Timing
Compromise on ErP requirements for solid fuel boilers (Lot 15) and solid fuel local space heaters (Lot 20) has been reached.The Energy Labellng was not discussed at this meeting.
June-July 2014
2022
Regulatory Committee
10.03.14
Expected vote in the Regulatory Committee on Ecodesign requirements
Ecodesign requirements entry into force- Efficiencies- Emissions
Labeling
(Boilers) P ≤ 70 kW
(Local) P ≤ 50 kW
Ecodesign reqs
(Boilers) P ≤ 1.000 kW
(Local) P ≤ 50 kW
SF- Boilers
- Local SH
In progress
??(2018?)
Label mandatory
Solid fuel boiler ErP/Labeling regulation: requirements
Solid fuel local space heaters (Lot 20) Solid fuel boilers (Lot 15)
By 2022 By 2022
Efficiency Open fronted
Closed fronted
Closed pellets
Cookers
ηs ≥ 42% ≥ 70% ≥ 79% ≥ 65%
Emissions
Efficiency P ≤ 20 kW P > 20 kW
ηs ≥ 75% ≥ 77%
By 2022 By 2022
In progress
Solid fuel boiler ErP/Labeling regulation: labelling
I. supplier’s name or trade mark;
II. supplier’s model identifier;
III. the energy efficiency class,;
IV.- V. the symbol for direct heat output symbol and its value in kW,
VI.- VII. for local space heaters with heat transfer to a fluid the symbol for indirect heat output and its value in kW,
I. supplier’s name or trade mark;
II. supplier’s model identifier;
III. the space heating function;
IV. the energy efficiency class,
V. the rated heat output in kW,
VI. for combination boilers, the water heating function.
Solid fuel local space heaters (Lot 20) Solid fuel boilers (Lot 15)
In progress
Package label
ErP/Labeling – Space Heaters & Water heaters
ErP Labeling
European Regulations
(implementing meausures of 2009/125/eu Directive; valid in the whole European Union, without national adoptons, variations, delays etc.)
What are they?
Binding to bear the EC mark
Covered products
BOILERS (gas, electrical, oil)
HEAT PUMPS (gas, electrical, oil)
mCHP (≤ 50 kW electrical power)
WATER HEATERS (gas, elettrici, oli)
RENEWABLE WHs (solar / HPWH)
HOT WATER STORAGE TANKS
P ≤ 400 kW
V ≤ 2.000 lt
P ≤ 70 kW
V ≤ 500 lt
What they establish?
Minimum energy Performances
+Environmental requirements (emissions, noise,
dismantling etc.) different by technologies
Energy labels (products & packages)
Technical fiches (products & packages)
Technical/promotional materials including
energy performance info
26.09.15 26.09.17 26.09.18
Label mandatoryClasses: A++ / G
First tier“Only HE”.
Second tierOnly for HP
56 mg/kWh (gas)120 mg/kWh (oil) Others (mCHP, GAHP)
Sound levelOnly for HP ≤ 6 kW
26.09.19
Labeling
(P < 70 Kw)
Minimum Perf
(P < 400 kW)
Other requis(P < 400 kW)
Entry into force
26.09.13
Update Intro new classes
BoilersHP
Mchp
Dates of adoption & main contents – Space Heaters
NOx
First tier‘light’
Second tier‘serious’
Third tierOnly for big capacity WH
Labeling
(P < 70 Kw)
Minimum perf
(P < 400 kW)
Other reqs.(P < 400 kW)
Sound levelOnly for HP <=6 kW
26.09.15 26.09.17 26.09.18 26.09.19
Entry into force
26.09.13
56 mg/kWh (gas)120 mg/kWh (oil) Others (mCHP, GAHP)
WH
HPWH
Label mandatory Classes: A / G
Performance limitsOnly for V < 2.000 l)
Label mandatory(Only for V < 500 l)
Storage tanks
NOx
Dates of adoption & main contents – Water Heaters
Update Intro new classes
SUPPLIER (product’s resp on the market)
Places on the market products ErP-compliant;
Places on the market products provided with:
− (product and/or package) Energy labels;
− (product and/or package) Technical fiches;
− Technical advertisements or promotions with info about product/package energy class;
DEALER
The exhibited devices or packages are equipped with the respective labels,
In case it is not expected for the end user to see the exhibited device, this is sold together with the information on energy efficiency;
Technical advertisements or promotions with info about product/package energy class;
by 26/09/2015…
Regulations will only apply to products’ on the market since 26/09/2015; those purchased before that date, and already available in sale points or distributors’ warehouses, will continue to be sold and installed, even though they are not in compliance with the new standards.
Dates of adoption & responsibilities
PACKAGES Package label can be filled by the supplier and by the dealer(distributor, installer, …). It must be exhibited to the end user;
Product and Package Labels: the principle
Products
Product’s label is provided by supplier
Dealer (i.e. distributor, installer etc.).has to exhibit the label;
Supplementary heater
Supplementary heater
Thermo-regulating device
Solar collector
Solar tank
Different label’s layout by technologies, but the same energy classes: comparability
EWH
HHP
Product and Package Labels: description
Thank you for your kind attention