Power Generation Cycles Vapor Power Generation The Rankine ... · PDF filePower Generation...

20
Department of Mechanical Engineering ME 322 Mechanical Engineering Thermodynamics Lecture 24 Power Generation Cycles Vapor Power Generation The Rankine Cycle

Transcript of Power Generation Cycles Vapor Power Generation The Rankine ... · PDF filePower Generation...

Page 1: Power Generation Cycles Vapor Power Generation The Rankine ... · PDF filePower Generation Cycles Vapor Power Generation ... Power Generation Cycles • Vapor Power Generation Cycles

Department of Mechanical Engineering

ME 322 – Mechanical Engineering

Thermodynamics

Lecture 24

Power Generation Cycles

Vapor Power Generation

The Rankine Cycle

Page 2: Power Generation Cycles Vapor Power Generation The Rankine ... · PDF filePower Generation Cycles Vapor Power Generation ... Power Generation Cycles • Vapor Power Generation Cycles

Power Generation Cycles

• Vapor Power Generation Cycles

– Working fluid experiences a phase change

– Example: Steam Power Plant

• Gas Power Generation Cycles

– Working fluid stays in the vapor or gas phase

– Example: Gas Turbine Engine

• Internal Combustion Engine (ICE) Cycles

– The working fluid is air in a closed piston-cylinder

– Example: Spark ignition ICE

– Example: Compression ignition ICE

2

Page 3: Power Generation Cycles Vapor Power Generation The Rankine ... · PDF filePower Generation Cycles Vapor Power Generation ... Power Generation Cycles • Vapor Power Generation Cycles

A Simple Vapor Power Plant

In ME 322, we are concerned

with subsystem A

3

Page 4: Power Generation Cycles Vapor Power Generation The Rankine ... · PDF filePower Generation Cycles Vapor Power Generation ... Power Generation Cycles • Vapor Power Generation Cycles

The Rankine Cycle - Components

(Heat Exchanger)

(Heat Exchanger)

4

Page 5: Power Generation Cycles Vapor Power Generation The Rankine ... · PDF filePower Generation Cycles Vapor Power Generation ... Power Generation Cycles • Vapor Power Generation Cycles

The Rankine Cycle – A Heat Engine

net cycleW W

LT

HTHT

LT

(Heat Source)

(Heat Sink)

5

Page 6: Power Generation Cycles Vapor Power Generation The Rankine ... · PDF filePower Generation Cycles Vapor Power Generation ... Power Generation Cycles • Vapor Power Generation Cycles

Component Analysis

1 2tW m h h

Turbine

2 3outQ m h h

Condenser

4 3pW m h h

Pump

1 4inQ m h h

Boiler 5

6

w

6

6 5

6 5

out w

out w p

Q m h h

Q m c T T

Page 7: Power Generation Cycles Vapor Power Generation The Rankine ... · PDF filePower Generation Cycles Vapor Power Generation ... Power Generation Cycles • Vapor Power Generation Cycles

Performance Parameters

Thermal Efficiency

energy sought

energy that costs $$th

Heat Rate

energy input to the cycle (Btu)HR

net work output (kW-hr)

Back Work Ratio

pump work requiredbwr

turbine work delivered

7

1 2 4 3 1 2 4 3

1 4 1 4

t p

in

m h h m h h h h h hW W

Q m h h h h

1 4

1 2 4 3

[Btu/hr][Btu/hr]

kW kW

in

t p

h hQ

W W h h h h

4 3 4 3

1 2 1 2

p

t

m h h h hW

W m h h h h

Page 8: Power Generation Cycles Vapor Power Generation The Rankine ... · PDF filePower Generation Cycles Vapor Power Generation ... Power Generation Cycles • Vapor Power Generation Cycles

Department of Mechanical Engineering

ME 322 – Mechanical Engineering

Thermodynamics

Vapor Power Generation

The Ideal Rankine Cycle

Page 9: Power Generation Cycles Vapor Power Generation The Rankine ... · PDF filePower Generation Cycles Vapor Power Generation ... Power Generation Cycles • Vapor Power Generation Cycles

The Ideal Rankine Cycle

• 1-2: Isentropic expansion through the turbine from a saturated (or superheated) vapor state to the condenser pressure

• 2-3: Heat transfer from the steam at constant pressure through the condenser to a saturated liquid

• 3-4: Isentropic process through the pump to the boiler pressure

• 4-1: Heat transfer to the steam at constant pressure through the boiler to complete the cycle

The ideal Rankine Cycle is

internally reversible

- No friction effects

Turbine and pump are

reversible and adiabatic

- Isentropic

9

Page 10: Power Generation Cycles Vapor Power Generation The Rankine ... · PDF filePower Generation Cycles Vapor Power Generation ... Power Generation Cycles • Vapor Power Generation Cycles

The Ideal Rankine Cycle

HP

LP

Boiler pressure

Condenser pressure

The ideal cycle also includes the possibility

of superheating the saturated vapor

10

Page 11: Power Generation Cycles Vapor Power Generation The Rankine ... · PDF filePower Generation Cycles Vapor Power Generation ... Power Generation Cycles • Vapor Power Generation Cycles

Department of Mechanical Engineering

ME 322 – Mechanical Engineering

Thermodynamics

Example

Ideal Rankine Cycle with Superheat

Page 12: Power Generation Cycles Vapor Power Generation The Rankine ... · PDF filePower Generation Cycles Vapor Power Generation ... Power Generation Cycles • Vapor Power Generation Cycles

Ideal Rankine Cycle with Superheat

Given: An ideal Rankine Cycle with water as the working

fluid with known properties as shown below.

Find:

(a) The net power

developed (Btu/hr)

(b) The thermal efficiency

(c) The heat rate

(d) The back work ratio

(e) The mass flow rate of

the cooling water

1

16

1600 psia1100 F

1.4 10 lbm/hr

PT

m

2 1 psiaP

5 60 FT

6 80 FT

12

Page 13: Power Generation Cycles Vapor Power Generation The Rankine ... · PDF filePower Generation Cycles Vapor Power Generation ... Power Generation Cycles • Vapor Power Generation Cycles

Ideal Rankine Cycle with Superheat

1

16

1600 psia1100 F

1.4 10 lbm/hr

PT

m

2 1 psiaP

5 60 FT

6 80 FT

13

Page 14: Power Generation Cycles Vapor Power Generation The Rankine ... · PDF filePower Generation Cycles Vapor Power Generation ... Power Generation Cycles • Vapor Power Generation Cycles

Ideal Rankine Cycle with Superheat

14

1

16

1600 psia1100 F

1.4 10 lbm/hr

PT

m

2 1 psiaP

5 60 FT

6 80 FT

The net power delivered from the

cycle is,

net t pW W W

The First Law applied to the turbine

1 2tW m h h

The enthalpy at the exit of the turbine can be found because

the turbine is isentropic,

Page 15: Power Generation Cycles Vapor Power Generation The Rankine ... · PDF filePower Generation Cycles Vapor Power Generation ... Power Generation Cycles • Vapor Power Generation Cycles

Ideal Rankine Cycle with Superheat

15

1

16

1600 psia1100 F

1.4 10 lbm/hr

PT

m

2 1 psiaP

5 60 FT

6 80 FT

The First Law applied to the pump,

4 3pW m h h

Page 16: Power Generation Cycles Vapor Power Generation The Rankine ... · PDF filePower Generation Cycles Vapor Power Generation ... Power Generation Cycles • Vapor Power Generation Cycles

Ideal Rankine Cycle with Superheat

16

1

16

1600 psia1100 F

1.4 10 lbm/hr

PT

m

2 1 psiaP

5 60 FT

6 80 FT

The thermal efficiency of the cycle is,

netth

in

W

Q

The heat transfer rate at the boiler is

determined from the First Law,

1 4inQ m h h

Page 17: Power Generation Cycles Vapor Power Generation The Rankine ... · PDF filePower Generation Cycles Vapor Power Generation ... Power Generation Cycles • Vapor Power Generation Cycles

Ideal Rankine Cycle with Superheat

17

1

16

1600 psia1100 F

1.4 10 lbm/hr

PT

m

2 1 psiaP

5 60 FT

6 80 FT

The heat rate and back work ratio

are defined as,

[Btu/hr]

HRkW

in

net

Q

W bwr

p

t

W

W

To determine the mass flow rate of the cooling water, draw a

system boundary around the condenser that keeps the heat

transfer all internal.

Page 18: Power Generation Cycles Vapor Power Generation The Rankine ... · PDF filePower Generation Cycles Vapor Power Generation ... Power Generation Cycles • Vapor Power Generation Cycles

Ideal Rankine Cycle with Superheat

18

1

16

1600 psia1100 F

1.4 10 lbm/hr

PT

m

2 1 psiaP

5 60 FT

6 80 FT

For the system identified (red),

2 5 3 6 0w wmh m h mh m h

2 3 6 5w pm h h m c T T

2 3 6 5wm h h m h h

Page 19: Power Generation Cycles Vapor Power Generation The Rankine ... · PDF filePower Generation Cycles Vapor Power Generation ... Power Generation Cycles • Vapor Power Generation Cycles

Ideal Rankine Cycle with Superheat

19

1

16

1600 psia1100 F

1.4 10 lbm/hr

PT

m

2 1 psiaP

5 60 FT

6 80 FT

EES Solution (Key Variables):

Page 20: Power Generation Cycles Vapor Power Generation The Rankine ... · PDF filePower Generation Cycles Vapor Power Generation ... Power Generation Cycles • Vapor Power Generation Cycles

Ideal Rankine Cycle with Superheat

20

1

16

1600 psia1100 F

1.4 10 lbm/hr

PT

m

2 1 psiaP

5 60 FT

6 80 FT

= 891.2 MBtu/hr

(350,257 hp)

= 1178 MBtu/hr

= 6.7 MBtu/hr

2063 MBtu/hr =

891.2 6.7 MBtu/hr0.429

2063 M/Btuhrth

6.7 MBtu/hrbwr 0.0075

891.2 MBtu/hr

2063 MBtu/hr 3412 Btu/hr

HR891.2 6.7 MBtu/hr kW

BtuHR 7958

kW-hr

Results: