POWER EQUIPMENT
INSTRUCTOR: ROBERT A. MCLAUGHLIN ZAILI THEO ZHAO
HIGH PRESSURE FITTINGSWEEK 13
23
:47
1
LEARNING OBJECTIVES
A boiler and pressure vessel. A level 1 boiler and a critical pressure boiler. The various pressure fittings used on boilers. The types of safety valves on boilers. The components of a boiler gauge glass. The proper procedures for removing a boilers
gauge glass from service, disassembly of the gauge, inspection and replacement and rebuild of a typical gauge glass.
23
:47
2
BOILER A steam boiler is a
closed pressure vessel in which water is heated to generate saturated steam. The water is heated by
the gasses of combustion.
A pressure vessel that produces hot water heated by the gasses of combustion is also a boiler.
23
:47
3
BOILER - CLASSIFICATION Boilers can be divided into
two pressure related categories: Low pressure – boilers
operating at 15 psi and below. High pressure – boilers
operating above 15 psi.
23
:47
4
Boilers can also be categorized into Level ratings. A Level 1 boiler is
When the temperature and pressure of a boiler equals 1500 or more.
All of the components of a level one boiler designed with a safety factor of 5 and are tested and given serial numbers.
23
:47
5
WHAT IS THE FACTOR OF SAFETY?
Ultimate strength divided by allowable working stress or bursting pressure divided by safe working pressure.
It can vary between four and seven depending on age, type of construction, and condition.
Use five for most calculations
23
:47
6
(R)(FS)
EtTS p
CRITICAL PRESSURE Many boilers operate at
pressures 1000 to 3000 psi.Some operate at
critical pressure – 3206 psi and 705.08oF Critical pressure is the
pressure at which steam and water at the same density.
All critical pressure boilers must have separate a pump to create circulation.
23
:47
7
DrainsAll steam and
water sections must have these.
The superheater will have drains.
The drums and headers will have drains.
EXTERNAL FITTINGS AND CONNECTIONS
23
:47
8
Venthigh
pressure globe valve at high point in the boiler
used when filling and emptying the boiler.
EXTERNAL FITTINGS AND CONNECTIONS
23
:47
9
EXTERNAL FITTINGS AND CONNECTIONS Sample
connections used for
taking boiler water samples.
Drains, vents, and sampling connections will all have high pressure rated globe valves attached to the connection.
23
:47
10
EXTERNAL FITTINGS AND CONNECTIONS Feed stop
and check valves to manually
regulate the flow of water to the drum.
23
:47
11
EXTERNAL FITTINGS AND CONNECTIONS Steam stop
valves located at
the superheater and desuperheater outlets.
Used to cut the boiler in or out of the main steam line.
23
:47
12
EXTERNAL FITTINGS AND CONNECTIONS Safety valve
two types (huddling chamber and nozzle reaction type).
They are not relief valves.
Question What is the
difference between the safety and relief valves?
23
:47
13
EXTERNAL FITTINGS AND CONNECTIONS Soot blower
Fixed and retractable
23
:47
14
INTERNAL FITTINGS
23
:47
15
23
:47
16
EXTERNAL FITTINGS AND CONNECTIONS Water gage glass –
attached directly to the drum, they allow the operator to see the water level in the drum. All boilers operating over
400 psi are required to have two independent means of determining water level.
One will be a gauge glass attached directly to the steam drum; one will be a remote water level indicator.
23
:47
17
EXTERNAL FITTINGS AND CONNECTIONS Temperature and
pressure gauges Superheated steam flow
indicators
23
:47
18
THE OPERATOR CONTROL THE SAFE OPERATION OF THE BOILERS.
23
:47
19
GAUGE GLASS Two independent means
of indication These can consist of two
gauge glasses attached to the drum, or a single gauge glass, and a remote water level indicator.
A gauge is located so that: the lowest visible part of the
glass is 2” above the lowest permissible drum water level
the upper most visible part of the glass is located 2” below the upper most
23
:47
20
GAUGE GLASSBoilers operating at
pressures below 250 psi can be fitted with tubular type gauge glasses
Above 250psi, flat type gauge glasses are required.
Isolation valves are required on each leg of the gauge glass
23
:47
21
GAUGE GLASS
There are high pressure glass type indicators that can be used instead of flat gauge glasses, for example, bicolor gauge glasses. Figure gauge glasses work on the
principle of light refraction
23
:47
22
GAUGE GLASS Every gauge glass will have valves to
isolate the gauge from the drum pressure for maintenance and emergency situations.
The isolation valves are usually of the quick closing type, capable of being closed with ¼ turn of the handles.
The handles will be connected by chain pulls so that an operator can pull on the chain and close both valves at the same time from a remote location.
The bottom isolation valve will always be fitted with a ball check device to prevent hot water from flowing through a broken gauge glass.
23
:47
23
GAUGE GLASS Each gauge glass assemble will
be fitted with a blowdown connection to: Insure that the connections between
the drum and gauge do not become clogged.
To help the operator tell the level in the glass.
If you are in doubt of the level in the glass, blow the glass down (open the gauge drain valve). If you blow a glass down, and you see
the water level go up through the glass, then the drum level is high.
If no level appears, then the level is high.
23
:47
24
GAUGE GLASS Leaks above the
actual water level will indicate higher than normal levels.
Leaks below the actual level will indicate lower than normal levels.
23
:47
25
GAUGE GLASS To blow a glass down for normal
maintenance: Disconnect the pull chains Close the top valve and open the
drain valve (blowdown valve). Let it drain for a few seconds.
Open the top isolation valve and close the bottom isolation valve. Leave the drain open for a few more seconds.
Close the drain valve. Open the bottom isolation valve
and reattach the chains.
23
:47
26
FLAT TYPE OF GAUGE GLASS CONSTRUCTION
1. BODY2. FLAT GUAGE GLASS3. MICA SHEET4. ASBESTOS GASKETS5. ASBESTOS CUSHIONS6. COVERPLATES7. STUDS8. NUTS
23
:47
27
GAUGE GLASSES AND TRY COCKS Both the water column and gauge
glass must blowdown daily Prevent sludge accumulations from
blocking lines Observe the level when it is blown.
When the valve is opened, the water should drop out of the glass rapidly.
When the valve is closed, it should return rapidly to its previous level.
If the glass water drains slowly This is an indication of clogging up. The situation must be corrected as
quickly as possible, even if the coiler has to be shut down.
23
:47
28
23
:47
29
There is one adjustment on the muddling chamber type safety valve
Adjusting ring
Question Who can
adjust the boiler safety setting pressure?
23
:47
30
There are two adjustments
Adjusting ring
Nozzle ring
Question How to
increase the blowdown pressure?
THE WIRES FOR REMOTE RELEASING SAFETY VALVE
23
:47
31
GATE VALVE RISE STEM
23
:47
32
GLOBE VALVE
23
:47
33
SWING CHECK VALVE
23
:47
34
BALL VALVE
23
:47
35
BUTTERFLY VALVE
23
:47
36
MARINE BOILER EXAMPLEWHAT ARE THESE FITTINGS? 1 - Gauge Glass or Water Column 2 - Main Steam, Safety, Auxilary
Steam Valves 3 - Pressure Gauge 4 - Surface Blow 5 - Skin Valve (through ship's side) 6 - Bottom Blow 7 - Hydrokineter (to increase water
circulation) 8 – Furnaces 9 - Fire-Tube bundles 10 - Main Feed Valve 11 - Auxiliary Feed Valve 12 - Deep Blue sea
23
:47
37
23
:47
38
THANK YOU