POOL INDEX - PolyAir · INDEX PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520...
Transcript of POOL INDEX - PolyAir · INDEX PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520...
P O O L
Pool water heating
Small pools ........................................................................................................................... 78
Large pools ........................................................................................................................... 80
Pool water heating and cooling
Domestic and commercial (centrifugal fan) ................................................ 81
Domestic and commercial (axial fan) .................................................................. 82
Pool water cooling
Domestic (centrifugal fan) .......................................................................................... 84
Domestic and commercial (axial fan) .................................................................. 85
Commercial (axial fan) ................................................................................................... 86
Commercial (centrifugal fan) .................................................................................... 87
Pool dehumidifiers
Wall mounted ..................................................................................................................... 88
Wall mounted/floor standing ................................................................................... 89
High capacity pool dehumidifiers
Floor standing ..................................................................................................................... 90
Ducted..................................................................................................................................... 91
Dehumidification with heat recovery .................................................................. 94
Pool air handling units
Dehumidification with heat recovery .................................................................. 95
With heat recovery .......................................................................................................... 97
With heat recovery and heat pump ..................................................................... 99
TO HEAT
TO DRY
TO COOL
TO VENTILATE
77
P O O L
I N D E X PolyAir Engineering Sàrl Champ Cheval 2CH - 1530 Payerne
+41 26 520 75 [email protected] www.polyair.ch
78
H P P 8
Features
�Quiet, aesthetically pleasing design
�ABS cabinet
�Scroll or Rotary compressor
�Titanium heat exchanger
�Reverse cycle defrost – operation to 3°C air temp
�Can heat water to 40°C
�'Smart' pool pump control
�Condensate collection
�Water flow switch
�Three year limited parts supply warranty, first year includes labour
Applications
�Outdoor pools
�Spa pools
�Above ground pools
�Wellness centres and therapy pools
CO M - PAC 8
Options
�Winter protection cover
* Output and input calculated @ 26°C water temperature
Specifications Units HPP/COM-PAC 6 HPP/COM-PAC 8 HPP/COM-PAC 12 HPP/COM-PAC 15 HPP/COM-PAC 20
Air temperature rangeWater temperature range
Output @ +25°C/55% RH ambientInput @ +25°C/55% RH ambient
Output @ +15°C/70% RH ambientInput @ +15°C/70% RH ambient
Output @ +5°C/100% RH ambientInput @ +5°C/100% RH ambient
COP 15°C ambientPower supplyMax. power inputMax. currentRefrigerantMin./max. pressureAir flowSound level @ 3mSound level @ 10mProduct size (w x d x h)Weight
°C°C
kWkW
kWkW
kWkW
V/HzkWA
Pam3/hdB(A)dB(A)mmkg
3-3510-40
7.21.3
5.71.2
4.71.1
4.75220-240/1ph/50
2.3310.59R410a
1.5/4.152200
3728
654 x 405 x 96851
3-3510-40
8.61.6
6.81.4
5.11.3
4.85220-240/1ph/50
2.7112.32R410a
1.5/4.152000
3829
654 x 405 x 96853
3-3510-40
12.42.2
9.82.0
8.21.9
4.90220-240/1ph/50
3.8317.41R410a
1.5/4.153900
3930
709 x 490 x 113072
3-3510-40
17.23.1
13.92.9
10.62.7
4.79220-240/1ph/50
5.9427.00R410a
1.5/4.153800
3930
709 x 490 x 113093
3-3510-40
22.24.2
18.03.9
13.73.7
4.61380-415/3ph/50
7.8212.30R410a
1.5/4.153800
5032
1225 x 807 x 570108
PROVISIONAL
P O O L WAT E R H E AT I N G
S M A L L P O O L S
79
TO
HE
AT
Features
�Plastisol coated cabinet and ABS top cover
�Intelligent electronic defrost
�Can be installed outside or in a plant room
�Choice of in-built thermostat positions
�High efficiency full flow Titanium condenser
�Leading brand rotary or scroll compressors
�Quiet, efficient owlet axial fans
�Water flow switch
�Pool pump synchronisation control
�Soft start options
� Pro-Pac X models operate in air temperatures above +5°C. These models are designed for seasonal use
� Pro-Pac Y models are fitted with reverse cycle defrost and will operate in air temperatures as low as -15°C, therefore they are suitable for all season use and indoor swimming pools
Applications
�Indoor or outdoor pools
�Private pools
�Spa pools
�Hotel pools
�Wellness centres
�Therapy pools
P R O - PAC 12
* Y model only -15 - +40°COutput and input calculated @ 26°C water temperature
Specifications Units PRO-PAC 8 PRO-PAC 12 PRO-PAC 16 PRO-PAC 22
Air temperature rangeWater temperature range
Output @ +25°C/55% RH ambientInput @ +25°C/55% RH ambient
Output @ +15°C/70% RH ambientInput @ +15°C/70% RH ambient
Output @ -3°C/100% RH ambient*Input @ -3°C/100% RH ambient*
°C°C
kWkW
kWkW
kWkW
5*-4010-40
10.52.0
8.51.8
4.71.6
5*-4010-40
14.12.5
11.32.3
6.42.0
5*-4010-40
16.62.9
13.62.7
8.02.3
5*-4010-40
22.94.5
18.74.1
10.93.6
Power supply
Minimum supply capacityRecommended supply fuse
V/HzV/Hz
A (1ph/3ph)A (1ph/3ph)
230/1ph/50
14/N/A20/N/A
230/1ph/50400/3ph/50
17/6.425/10
230/1ph/50400/3ph/50
19.8/830/15
230/1ph/50400/3ph/50
31/1342/20
Air flow m3/h 2200 3300 3500 4100Flow ratePressure dropWater connections
l/minm hdinch
750.1
1½ BSPM or 50mm female
750.1
1½ BSPM or 50mm female
1250.1
1½ BSPM or 50mm female
1670.6
1½ BSPM or 50mm female
CompressorCondenserSound level @ 10mSound level @ 3m
dB(A)dB(A)
1 x RotaryTitanium
3850
1 x RotaryTitanium
3947
1 x ScrollTitanium
4148
1 x ScrollTitanium
4452
Product size (w x d x h)Weight - X modelsWeight - Y models
mmkgkg
1237 x 535 x 7259196
1237 x 535 x 72596
112
1237 x 535 x 725118136
1237 x 535 x 904122141
P O O L WAT E R H E AT I N G
S M A L L P O O L S
80
Features
�Capacities from 32kW to 125kW
�Purpose designed components for pool heating
�Can be installed outside or in a plant room
�High efficiency spiral wound full flow titanium condenser
�Leading brand scroll compressors
�Quiet, efficient owlet axial fans
�Plastisol coated cabinet
�Water flow switch
�Condensate collector
� Standard models operate in air temperatures above +10°C. These models are designed for seasonal use
� Pro-Pac Y models are fitted with reverse cycle defrost and will operate in air temperatures as low as -15°C, therefore they are suitable for all season use and indoor swimming pools
Applications
�Indoor or outdoor pools
�Water parks
�Hotel pools
�Holiday parks and campsites
P R O - PAC 30
Options
�Soft start
�High pressure fan
* Y model only -15 - +40°COutput and input calculated @ 26°C water temperature
Specifications Units PRO-PAC 30 PRO-PAC 45 PRO-PAC 70 PRO-PAC 90 PRO-PAC 140
Air temperature rangeWater temperature range
Output @ +25°C/55% RH ambientInput @ +25°C/55% RH ambient
Output @ +15°C/70% RH ambientInput @ +15°C/70% RH ambient
Output @ -3°C/100% RH ambient*Input @ -3°C/100% RH ambient*
Power supplyMinimum supply capacityRecommended supply fuseNominal air flowWater flowPressure dropWater connectionsCompressorCondenserSound level @ 10mSound level @ 3mProduct size (w x d x h)Weight - Standard modelsWeight - Y models
°C°C
kWkW
kWkW
kWkW
V/HzAA
m3/hl/minm hdinch
dB(A)dB(A)mmkgkg
15-4010-38
36.36.7
29.66.2
17.45.4
400/3ph/502030
55002500.7
2 Union1 x Scroll Titanium
5464
1585 x 790 x 1080219233
15-4010-38
45.28.6
36.98.0
21.76.9
400/3ph/502230
120003000.4
2 Union1 x Scroll Titanium
5565
1695 x 1060 x 1330330337
15-4010-38
68.312.3
55.711.4
32.79.8
400/3ph/503550
140005001.5
3 BSPM1 x Scroll Titanium
5970
1840 x 1190 x 1310417435
15-4010-38
96.318.1
78.516.8
46.114.5
400/3ph/504360
240006001.4
3 BSPM2 x Scroll Titanium
5565
2095 x 1190 x 1350633661
15-4010-38
136.624.7
111.322.8
65.419.6
400/3ph/5067
1002800010002.1
4 BSPM2 x Scroll Titanium
5970
2250 x 1650 x 1340816880
P O O L WAT E R H E AT I N G
L A R G E P O O L S
81
TO
HE
AT
TO
CO
OL
AW 1234 B H C
Options
�Chiller or heater only
�Rear or top outlet on 3034 or 7034
�Soft start
�High pressure fan
�3ph, 60Hz versions
Features
�Designed for the Gulf climate
�Reduced energy consumption
�No additional equipment required
�Simple installation and long service life
�Suitable for all year round pool use
�Minimal maintenance
�Low operating costs
�Zero ozone depleting R134a refrigerant – unlike R22 and R407C, R134a will operate reliably throughout every possible Gulf climatic condition
�Fully automatic operation
�Water flow switch (3034 & 7034 models)
�Weather and corrosion resistant construction including plastisol coated galvanised steel cabinet and epoxy coated coils
�90/10 marine grade heat exchangers
Applications
�Outdoor and indoor pools (Gulf and SE Asia)
�Health clubs and wellness centres
�Hotels and spa pools
Specifications Units AW 634 AHC AW 1234 BHC AW 3034 BHC AW 7034 BHC
Air temperature rangeWater temperature range
Heating output @ +20°C/85% RH ambientHeating input @ +20°C/85% RH ambient
Cooling output @ +45°C/50% RH ambientCooling input @ +45°C/50% RH ambient
°C°C
kWkW
kWkW
15-5510-40
7.41.3
5.51.9
15-5510-40
11.82.1
9.83.2
15-5510-40
35.46.6
29.29.9
15-5510-40
60.010.8
49.516.3
Power supplyRecommended max. supply & fuse capacityMax. starting current standard (LRA)
V/HzAA
240/1ph/501332
400/3ph/501648
400/3ph/5035
126
400/3ph/5060
126Nominal air flowFan external resistance (standard)High pressure fan
m3/hPaPa
150050
30000
100000
117000
Water flow ±10%Pressure drop (water)Water connectionsCondensate water connections
l/minm hd"BSPM"BSPM
332.1¾¾
332.2¾¾
662.51½ 1½
1305.31½1½
Compressor typeFan typeSound level @ 3mProduct size (w x d x h)Weight
dB(A)mmkg
Recip1x Centrifugal
63820 x 702 x 762
111
Scroll1x Centrifugal
651060 x 705 x 807
157
Scroll1x Centrifugal
721700 x 1090 x 1212
411
Scroll1x Centrifugal
681950 x 1340 x 1212
690
Variable to meet customer requirements
* Output and input calculated at water temperature 26°C for heating, and 32° for cooling
P O O L WAT E R H E AT I N G A N D CO O L I N G
D O M E S T I C A N D CO M M E R C I A L (CENTRIFUGAL FAN)
82
Features
�Designed for the Gulf climate
�Zero ozone depleting R134a refrigerant – ensures reliable, efficient operation regardless of air temperature
�Titanium or CuNi heat exchanger
�Fully automatic operation
�Scroll compressors
�Water flow switch on all models
�Comprehensive circuit protection
�Quiet, efficient owlet axial fans
�Weather-proof construction
�Digital thermostat – choice of in-built positions
Options
�Chiller or heater only
�3ph, 60Hz versions
�Soft start
�High pressure fan
�Condensate insulation kit for plant room installations
Applications
�Outdoor and indoor pools (Gulf and SE Asia)
�Health clubs and wellness centres
�Hotels and spa pools
P R O - PAC 16 B H C
Specifications Units PRO-PAC 16BHC PRO-PAC 22BHC
Air temperature rangeWater temperature range
Heating output @ +20°C/85% RH ambientHeating input @ +20°C/85% RH ambient
Cooling output @ +45°C/50% RH ambientCooling input @ +45°C/50% RH ambient
°C°C
kWkW
kWkW
10-5510-38
11.82.1
9.83.2
10-5510-38
15.02.7
12.44.1
Power supplyMin. supply capacityRecommended supply fuseMax. starting current standard (LRA)Max. starting current soft start (LRA)
V/HzAAAA
400/3ph/5010164825
400/3ph/5013204825
Nominal air flowFan external resistance (standard)
m3/hPa
40000
50000
Water flow ±10% (CuNi/Titanium heat exchanger)Pressure drop (water)Water connectionsCondensate water connectionsCompressor typeFan typeSound level @ 3m
l/minm hdinch
" BSPM
dB(A)
n/a/123n/a/0.2
1½ F/PVC½ ABS
1 x Scroll1 x Axial
48
n/a/123n/a/0.2
1½ F/PVC½ ABS
1 x Scroll1 x Axial
52Product size (w x d x h)Weight
mmkg
1264 x 600 x 725131
1264 x 600 x 725145
* Output and input calculated at water temperature 26°C for heating, and 32° for cooling
P O O L WAT E R H E AT I N G A N D CO O L I N G
D O M E S T I C A N D CO M M E R C I A L ( AX I A L FA N )
83
TO
HE
AT
TO
CO
OL
Options
�Chiller or heater only
�3ph, 60Hz versions
�Soft start
�High pressure fan
�Condensate insulation kit for plant room installations
Applications
�Outdoor and indoor pools (Gulf and SE Asia)
�Health clubs and wellness centres
�Hotels and spa pools
Features
�Zero ozone depleting R134a refrigerant – ensures reliable, efficient operation regardless of air temperature
�Titanium or CuNi heat exchanger
�Fully automatic operation
�Scroll compressors
�Water flow switch on all models
�Comprehensive circuit protection
�Quiet, efficient owlet axial fans
�Weather-proof construction
�Digital thermostat
P R O - PAC 30 B H C
Specifications Units PRO-PAC 30BHC
PRO-PAC 45BHC
PRO-PAC 70BHC
PRO-PAC 90BHC
PRO-PAC 140BHC
Air temperature rangeWater temperature range
Heating output @ +20°C/85% RH ambientHeating input @ +20°C/85% RH ambient
Cooling output @ +45°C/50% RH ambientCooling input @ +45°C/50% RH ambient
°C°C
kWkW
kWkW
10-5510-40
31.05.5
25.58.3
10-5510-40
36.46.7
30.010.0
10-5510-40
61.910.5
51.016.2
10-5510-40
72.713.3
29.920.0
10-5510-40
123.821.0
102.132.4
Power supplyMin. supply capacityRecommended supply fuseMax. starting current standard (LRA)Max. starting current soft start (LRA)
V/HzAAAA
400/3ph/5021309633
400/3ph/502540
10234
400/3ph/5042609633
400/3ph/505070
10234
400/3ph/5084
1259633
Nominal air flowFan external resistance (standard)
m3/hPa
55000
110000
140000
220000
280000
Water flow ±10% (CuNi/Titanium heat exchanger)
Pressure drop (water)Water connectionsCondensate water connectionsCompressor typeFan typeSound level @ 3m
l/minm hdinch
" BSPM
dB(A)
n/a/250n/a/0.7
n/a/2 union1½
1 x Scroll1 x Axial
64
66/3004.5/0.4
1½ BSPM/2 union1½
1 x Scroll1 x Axial
65
133/5003.4/1.5
1½/3 BSPM1½
2 x Scroll1 x Axial
70
166/6004.5/1.7
1½/3 BSPM1½
2 x Scroll2 x Axial
65
266/10005.3/2.1
2/4 BSPM1½
4 x Scroll2 x Axial
70Width DepthHeightWeight
mmmmmmkg
1525790
1080219
166510601310329
181011901310549
206511901330599
2210165013401065
* Output and input calculated at water temperature 26°C for heating, and 32° for cooling
P O O L WAT E R H E AT I N G A N D CO O L I N G
D O M E S T I C A N D CO M M E R C I A L ( AX I A L FA N )
84
Features
�Domestic sizes giving up to 900 litres per hour of cold water production
�Fully packaged, robust and weatherproof construction
�Quiet operation
�Purpose-built for operation in the Gulf region
�Certified cupronickel WRAS* approved heat exchanger to withstand pool chemicals and allow the unit to be used in a direct system
�Non ozone depleting refrigerant (R134a)
* WRAS is a conformance mark that demonstrates that an item complies to strict standards set out by UK water regulations. This standard gives you peace of mind that approved products will not contaminate your water supply and are safe to use within their stated pressure and temperature ranges.
WA 1234 B C
Applications
�Homes and villas
�Plunge pools
Options
�Available in 60Hz
Specifications Units WA 634ACL WA 634ACH WA 1234BC
Air temperature rangeWater temperature range
Output @ 32°C waterInput @ 32°C water
Output @ 10°C waterInput @ 10°C water
°C°C
kWkW
kWkW
0-5510-40
5.51.9
2.81.4
10-5510-40
5.51.9
2.81.4
10-5510-40
9.83.2
5.92.5
Nominal cold water productionMin./max. tank size
l/hl
50060/500
50060/500
900110/1000
Electrical inputPower supplyMax. supply fuseStarting current
kWV/Hz
AA
1.9220-240/1ph/50
1332
1.9220-240/1ph/50
1332
3.2400/3ph/50
1648
Water flowFlow resistanceConnections
l/min ±10%mhdinch
332.1
¾ BSPM
332.1
¾ BSPM
332.1
¾ BSPMNominal air flowFan external resistance (standard)
m³/hPa
150050
150050
300050
Fan typeSound pressure level @ 3mProduct size (w x d x h)Weight
dB(A)mmkg
1 x Centrifugal63
820 x 702 x 762111
1 x Centrifugal63
820 x 702 x 762111
1 x Centrifugal65
1060 x 705 x 807157
* Cooling output and input calculated at +45°C/50% RH ambient air
P O O L WAT E R CO O L I N G
D O M E S T I C ( C E N T R I F U G A L FA N )
85
TO
CO
OL
Features
�Domestic sizes giving up to 900 litres per hour of cold water production
�Mono-block design with choice of in-built thermostat positions
�Fully packaged, robust and weatherproof construction
�Quiet operation
�Purpose-built for operation in the Gulf region
�Certified cupronickel WRAS* approved heat exchanger to withstand pool chemicals and allow the unit to be used in a direct system
�Non ozone depleting refrigerant (R134a)
* WRAS is a conformance mark that demonstrates that an item complies to strict standards set out by UK water regulations. This standard gives you peace of mind that approved products will not contaminate your water supply and are safe to use within their stated pressure and temperature ranges.
Applications
�Sports academies
�Sports training facilities
�Plunge pools
�Therapy pools
P R O - PAC 16 B C
Options
�Available in 60Hz
Specifications Units PRO-PAC 16BC PRO-PAC 22BC
Air temperature rangeWater temperature range
Output @ 32°C waterInput @ 32°C water
Output @ 10°C waterInput @ 10°C water
°C°C
kWkW
kWkW
10-5510-38
9.83.2
5.92.5
10-5510-38
12.44.1
7.53.3
Power supplyMin. supply capacityRecommended supply fuseMax. starting current standard (LRA)Max. starting current soft start (LRA)
V/HzAAAA
400/3ph/5010164825
400/3ph/5013204825
Nominal air flowFan external resistance (standard)
m3/hPa
40000
50000
Water flow ±10% (CuNi heat exchanger)Pressure drop (water)Water connections
l/minm hd
" BSPM
334.2
1½ F
334.2
1½ FCompressor typeFan typeSound pressure level @ 3mProduct size (w x d x h)Weight
dB(A)mmkg
1 x Scroll1 x Axial
481264 x 600 x 725
131
1 x Scroll1 x Axial
521264 x 600 x 725
145* Cooling output and input calculated at +45°C/50% RH ambient air
P O O L WAT E R CO O L I N G
D O M E S T I C A N D CO M M E R C I A L ( AX I A L FA N )
86
Features
�Fully packaged, robust and weatherproof construction
�Quiet operation
�Purpose-built for operation in the Gulf region
�Certified cupronickel WRAS* approved heat exchanger to withstand pool chemicals and allow the unit to be used in a direct system
�Non ozone depleting refrigerant (R134a)
* WRAS is a conformance mark that demonstrates that an item complies to strict standards set out by UK water regulations. This standard gives you peace of mind that approved products will not contaminate your water supply and are safe to use within their stated pressure and temperature ranges.
Applications
�Sports academies
�Sports training facilities
�Plunge pools
�Therapy pools
P R O - PAC 140 B C
Options
�Available in 60Hz
Specifications Units PRO-PAC 30BC PRO-PAC 45BC PRO-PAC 70BC PRO-PAC 90BC PRO-PAC 140BC
Air temperature rangeWater temperature range
Output @ 32°C waterInput @ 32°C water
Output @ 10°C waterInput @ 10°C water
°C°C
kWkW
kWkW
10-5510-38
25.58.3
15.56.6
10-5510-38
30.0 10.0
18.28.0
10-5510-38
51.0 16.2
30.912.8
10-5510-38
29.920.0
36.316.0
10-5510-38
102.132.4
61.925.5
Power supplyMin. supply capacityRecommended supply fuseMax. starting current standard (LRA)Max. starting current soft start (LRA)
V/HzAAAA
400/3ph/5021309633
400/3ph/502540
10234
400/3ph/5042609633
400/3ph/505070
10234
400/3ph/5084
1259633
Nominal air flowFan external resistance (standard)
m3/hPa
55000
110000
140000
220000
280000
Water flow ±10% (CuNi heat exchanger)Pressure drop (water)Water connections
l/minm hd
" BSPM
662.11½
664.51½
1333.41½
1664.51½
2665.32
Compressor typeFan typeSound pressure level @ 3mProduct size (w x d x h)Weight
dB(A)mmkg
1 x Scroll1 x Axial
621525 x 790 x 1080
219
1 x Scroll1 x Axial
641665 x 1060 x 1310
329
2 x Scroll1 x Axial
681810 x 1190 x 1310
549
2 x Scroll2 x Axial
702065 x 1190 x 1330
599
4 x Scroll2 x Axial
712210 x 1650 x 1340
1065* Cooling output and input calculated at +45°C/50% RH ambient air
P O O L WAT E R CO O L I N G
CO M M E R C I A L ( AX I A L FA N )
87
TO
CO
OL
Applications
�Homes and villas
�Hotels
�Pools and sports training facilities
WA 7034 B C
Options
�Rear or top outlet
�Soft start
�High pressure fan
�3ph, 60Hz versions
Features
�Zero ozone depleting R134a refrigerant - unlike R22 and R407C, R134a will operate reliably throughout every possible Gulf climatic condition
�Fully automatic operation
�Certified cupronickel WRAS* approved heat exchanger to withstand pool chemicals and allow the unit to be used in a direct system
�Water flow switch
�Weather and corrosion resistant construction including plastisol coated galvanised steel cabinet and epoxy coated coils
�90/10 marine grade heat exchangers
* WRAS is a conformance mark that demonstrates that an item complies to strict standards set out by UK water regulations. This standard gives you peace of mind that approved products will not contaminate your water supply and are safe to use within their stated pressure and temperature ranges.
Specifications Units WA 3034BC WA 7034BC
Air temperature rangeWater temperature range
Output @ 32°C waterInput @ 32°C water
Output @ 10°C waterInput @ 10°C water
°C°C
kWkW
kWkW
10-5510-40
29.29.9
17.77.9
10-5510-40
49.516.3
30.013.0
Power supplyRecommended maximum supply & fuse capacityMaximum starting current standard (LRA)
V/HzAA
400/3ph/5035
126
400/3ph/5060
126Nominal air flowFan external resistance (standard)High pressure fan
m3/hPaPa
100000
Variable to meet customer requirements
117000
Variable to meet customer requirements
Water flow ±10%Pressure drop (water)Water connectionsCondensate water connections
l/minm hdinchinch
662.5
1½ BSPM1½ BSPM
1305.3
1½ BSPM1½ BSPM
Gas typeCompressor typeFan typeSound level @ 3mProduct size (w x d x h)Weight
dB(A)mmkg
R134aScroll
1x Centrifugal 72
1700 x 1090 x 1212411
R134aScroll
1x Centrifugal 68
1950 x 1340 x 1212690
* Cooling output and input calculated at +45°C/50% RH ambient air
P O O L WAT E R CO O L I N G
CO M M E R C I A L ( C E N T R I F U G A L FA N )
88
Features
�High moisture extraction for low power consumption
�Zero ozone depleting refrigerant
�Low internal operating pressures = long useful life
�Fan cycle or continuous mode
�Air outlet adjustable to horizontal or vertical
�Hot gas defrost (allows operation to 5°C air temperature)
�Many options for flexible installation
�Remote humidistat and on/off function
Applications
� Indoor pools
� Therapy pools
� Health clubs and wellness centres
� Hotels and spa pools
� Holiday parks and campsites
Specifications Units DH 33 DH 55
Operating temperature rangeDehumidification @ 30°C/60% RHHeat recovered to air @ 30°C/60% RHAir flowExternal static pressureSound pressure level @ 3mRefrigerantPower supplyNominal power consumptionFLAMaximum supply fuseLRA (compressor start)Heater typeHeat output @ 80°C flowFlow rateProduct size (w x d x h)WeightCondensate drain size (flexible plastic hose)
°Cl/hkW
m3/hPa
dB(A)
V/HzkWAAA
kWl/minmmkg
mm
5-351.251.9440
048
R407c230/1ph/50
0.754.41015
Optional LPHW35
780 x 255 x 6533716
5-352.53.5740
048
R407c230/1ph/50
1.27.51330
Optional LPHW55
1245 x 255 x 6535816
D H 55
D H 33
Options
�Through the wall version
�LPHW air heater
�Air filter
�Floor stand kit
P O O L D E H U M I D I F I E R S
WA L L M O U N T E D
89
TO
DR
Y
C D P 40 T Features
�Low sound level
�Low energy consumption
�Evaporator and condenser coils are epoxy coated
�Metal parts are powder coated before assembly
�Optional remote control
�Integrated control of heating and humidity (ON/OFF)
�BMS communication (Modbus)
�USB gate for PC Tool
�Direct connection of 230 V on external box
Applications
� Indoor pools
� Therapy pools
� Health clubs and wellness centres
� Hotels and spa pools
� Holiday parks and campsites
Optional accessories
�Wireless remote control DRC1
�Floor mounting kit
�Water heating coils
�Control valve for water heating coil
�Electric heating coils
�Exhaust fans
�Through-wall duct kit with filter, extension kit and alu grill
�Duct lead-in adapter
Specifications Units CDP 40 CDP 40(T) CDP 50 CDP 50(T) CDP 70 CDP 70(T)
Operating temperature rangeOperating humidity rangeDehumidification @ 28°C/60% RHAir flowSound pressure levelPower supplyProduct size (h x w x d)Weight
°C% RHl/24hm3/hdB(A)V/Hzmmkg
10-3640-100
3440046
230/1ph/50770 x 1010 x 326
56.5
10-3640-100
3440043
230/1ph/50700 x 998 x 304
57.5
10-3640-100
5268047
230/1ph/50700 x 1160 x 326
65.0
10-3640-100
5268044
230/1ph/50770 x 1148 x 304
66.0
10-3640-100
6990050
230/1ph/50770 x 1495 x 326
75.5
10-3640-100
6990047
230/1ph/50700 x 1483 x 304
77.5
C D P 70
P O O L D E H U M I D I F I E R S
WA L L M O U N T E D / F LO O R S TA N D I N G
90
D H 110Features
�High moisture extraction for low power consumption
�Corrosion free, easy to clean aluminium air grille with easy clean air filter
�Zero ozone depleting refrigerant
�Low internal operating pressures = long useful life
�Adjustable air outlet
�Quiet centrifugal fans, two speeds
�Hot gas defrost (allows operation to 5°C air temperature)
�Remote humidistat and on/off function
Specifications Units DH 75AX DH 110AX
Operating temperature rangeDehumidification @ 30°C/60% RHHeat recovered to air @ 30°C/60% RHAir flowExternal static pressureSound pressure level @ 3mRefrigerantPower supplyNominal power consumptionFLAMaximum supply fuseLRA (compressor start)Heater typeHeat output @ 80°C flowFlow rateProduct size (w x d x h)WeightCondensate drain size (brass compression)
°Cl/hkW
m3/hPa
dB(A)
V/HzkWAAA
kWl/minmmkg
mm
5-353.64.0
11800
53R407c
230/1ph/501.59.51355
Optional LPHW8.99.6
1520 x 385 x 79614315
5-354.55.2
11800
53R407c
230/1ph/502.1122066
Optional LPHW8.99.6
1520 x 385 x 79614415
Applications
� Indoor pools
� Therapy pools
� Health clubs and wellness centres
� Hotels and spa pools
� Holiday parks and campsites
Options
�Through the wall version
�LPHW air heater complete with 3 way valve and 12V thermostat interlock
�400V-3ph option for DH 110
H I G H C A PA C I T Y P O O L D E H U M I D I F I E R S
F LO O R S TA N D I N G
91
TO
DR
Y
Features
�The CDP 75-125-165 are built into a cabinet made of hot-galvanized, powder painted and double-skinned panels with 50mm insulation
�Evaporator and condenser coils are protected against corrosion
�The condensate outlet is located on the air inlet side
�The outlet stub can be connected to a water hose
�Air inlet through a filter placed in a removable frame
�Dry air outlet positioned either horizontally or vertically through the top of the unit
�The access for inspection can be moved to the opposite side
�Fresh air inlet possible through fresh air duct
�Can be supplied with an optional water-cooled condenser –coupling pipes are made of copper
�Rotary/reciprocating compressor
�Radial fan
Applications
�Hotel pools
�Private pools
�Therapy pools
�Wellness centres
�Changing rooms
Optional accessories
�Room hygrostat
�Duct hygrostat
�Room thermostat
�Water heating coil
�Shock-absorbing floor mounting kit
�Wall mounting kit
�Defrost sensor
�Failure monitoring kit
C D P 75
Specifications Units CDP 75 CDP 125 CDP 165
Dehumidification @ 28°C/60% RH l/24h 74 124 162Operating temperature rangeOperating humidity range
°C%
20-3840-100
20-3840-100
20-3840-100
Air flow m3/h 1500 2500 3600Power supply V/Hz 230/1ph/50 230/1ph/50 + 400/3ph/50 400/3ph/50Sound level dB(A) 58 60 63Product size (h x w x d) mm 650 x 1155 x 725 850 x 1300 x 900 975 x 1400 x 1010Weight kg 130 160 190Water-cooled condenser Optional Optional Optional
H I G H C A PA C I T Y P O O L D E H U M I D I F I E R S
D U C T E D
92
Features
All models:
� Pool hall dehumidification
� Dynamic heat pump heat recovery
� Constant flow fan with two speed settings
� Remote control panel (12V) with 1.8m lead (10m cable optional)
LPHW Air models add:
� Integral LPHW heat exchanger for air heating
LPHW Air+Water models add:
� Integral LPHW heat exchangers for pool and air
A A 300A A 500
Applications
� Indoor pools
� Private pools
� Therapy pools
� Health clubs and wellness centres
� Hotels and spa pools
Specifications Units AA 300 AA 500
Air flowExternal available static pressureDehumidification @ 30°C/60% RH
m³/hPal/h
1300 ± 10% 2503.6
1800 ± 10% 2504.5
Heat to airVia heat pump kW 4.4 6.1Via LPHW (LPHW Air models) kW 7.3 7.5Total (heat pump + LPHW) kW 9.8 11.7Heat to waterVia LPHW (LPHW Air + Water models) kW 9.5 9.5Product size (h x w x d) mm 850 x 1027 x 730 850 x 1027 x 730Weight kg 111 111
Options
� Flexible flange kit to reduce vibration
F L A N G E K I T
H I G H C A PA C I T Y P O O L D E H U M I D I F I E R S
D U C T E D
93
TO
DR
Y
Features
� User friendly control system for high-quality demand management. Automatic monitoring and control of temperature and humidity of the pool hall. Special developed software which always finds the most energy efficient way to run the unit under different conditions.
� Cooling circuit with optional built-in water cooled condenser for heating of pool or domestic water and external condenser for hot countries
� Optional DX or water cooling coil
� Highly efficient EC plug fans with low power consumption
� High efficient M5 bag filters with large surface and low pressure drop
� Load bearing frame construction module with hot dip galvanised, powder painted sandwich panels with 50mm mineral wool insulation and bottom frame with adjustable feet.
� All modules and internal components are specifically designed to withstand the aggressive swimming pool environment (Corrosion class C4 according to EN/ISO 12944-2), with epoxy coated crossflow heat exchanger, coils with aluminium frame, pre painted fins and epoxy coating with all fasteners, bolts and nuts specially protected.
� Large inspection doors with strong hinges and tongue locks and handles for easy access for service
� Modular unit for easy and quick installation with all sensors and electrical components already connected. Separate control panel fitted with cables and plugs for quick electrical connection between unit and panel.
� BMS communication with either Modbus or BACnet
D A N X A F
Applications
� Private pools
� Hotel pools
� Spa resorts
� Municipal/commercial swimming pools
� Wellness centres
Specifications Units 3/6 AF 5/10 AF 5/10s AF 7/14 AF 7/14s AF 12/24 AF 1224s AF
Dehumidification @ 28°C/60% RHOperating temperature rangeOperating humidityAir flowExternal duct pressureOutdoor airPower supplyMax. power consumptionHeightWidthDepthWeight
l/h°C%
m3/hPa%
V/HzkWmmmmmmkg
1322-3650-8048503001-30
400/3ph/508.6
11153380
88575
2022-3650-8073003000-30
400/3ph/5012.311153380140800
2522-3650-8095003000-30
400/3ph/5016.111153380140800
3022-3650-8012000
3000-30
400/3ph/5022.111953350190
1125
3922-3650-8014000
3000-30
400/3ph/5024.111953350190
1200
5222-3650-8019000
3000-30
400/3ph/5031.714854125220
1650
6022-3650-8024000
3000-30
400/3ph/5042.814854125220
1675
H I G H C A PA C I T Y P O O L D E H U M I D I F I E R S
D U C T E D
94
Specifications Units AW 600 AA 600 AW 900 AA 900 AW 1200 AA 1200 AW 1500 AA 1500
Air flowExternal available static pressureFresh air flow (option)External available staticDehumidifcation @ 30oC/60% RHDehumidifcation @ 30oC/70% RH
m3/hPa
m3/hPal/hl/h
2000330
0-9001004.65.5
2000330
0-9001004.65.5
2500220
0-9001006.57.8
2500220
0-9001006.57.8
3500290
0-9001008.5
10.8
3500290
0-9001008.5
10.8
4300350
0-90010010.513.2
4300350
0-90010010.113.2
Heat to airNet via heat pump (Mode B)Via standard LPHW @ 80oCMax. available (Mode B + standard LPHW)Via upgraded LPHW @ 55oCMax. available (Mode B + upgraded LPHW)
kWkWkWkWkW
5.111.014.09.4
12.7
5.111.014.09.4
12.7
7.113.518.611.516.9
7.113.518.611.516.9
10.024.030.020.427.0
10.024.030.020.427.0
14.028.036.023.836.8
14.028.036.023.836.8
Heat to waterNet via heat pump (Mode A)Via LPHW @ 80oCMax. available (Mode A + LPHW)
kWkWkW
5.518.023.5
000
7.430.037.4
000
10.030.040.0
000
12.540.052.5
000
Nominal power consumed kW 2.1 2.1 2.8 2.8 3.6 3.6 4.7 4.7
AW denotes heat recovery to air/water and LPHW heaters for air/water AA denotes heat recovery to air and optional LPHW heater for air only
Features
� Pool hall dehumidification
� Dynamic heat pump heat recovery to pool and air
� Constant flow EC fan (models 600, 900, 1200)
� Speed controllable EC fan (model 1500)
� PLC control with 3.5" touchscreen user interface
� Remote monitoring/control
AA+LPHW models add:
� Integral LPHW heat exchanger for air heating
AW models add:
� Dynamic heat pump heat recovery to pool and air
� Integral LPHW heat exchangers for pool and air
Applications
�Spa and therapy pools
�Hotel pools and wellness centres
�Holiday parks & campsites
�School pools
VA R I H E AT AW 1200Options
� Fresh air module
� Upgraded LPHW heat exchanger for air
� Electric resistance air heaters (6/12/18kW)
� Air cooling with remote condenser
� Titanium pool condenser (AW models only)
Electrical heater option notes
� In lieu of LPHW heat exchangers
� 6kW or 12kW is available for 600 and 900 models
� 12kW or 18kW is available for 1200 and 1500 models
H I G H C A PA C I T Y P O O L D E H U M I D I F I E R S
D E H U M I D I F I C AT I O N W I T H H E AT R E CO V E RY
95
TO
VE
NT
ILA
TE
Applications
�Health clubs and wellness centres
�Holiday parks and campsites
�Hotel and spa pools
�Leisure centres
�Water parks
�School pools
Features
�Dynamic heat pump heat recovery to pool and air
�Self-regulating fresh air control with heat recovery
�Automatic control of exhaust air volume to match pool usage
�Free-cooling (Delta 1-2)
�Free-cooling and heat pump air cooling (Delta 4-16)
�Integral LPHW heat exchangers for pool and air
�Speed controllable EC/inverter fans in all models
�PLC control with 5.7" touchscreen user interface
�Remote monitoring/control
Options
�Delta 1-6 single or three phase
�Delta 8-16 three phase only
�Upgraded LPHW heat exchanger for air heating
�Left-hand or right-hand orientation (Delta 4-16)
�Top, side or bottom supply fan outlet
�Front or rear supply fan outlet (Delta 14-16)
�Rear exhaust and fresh air connections (Delta 14-16)
D E LTA 4
Specifications Units DT 1 DT 2 DT 4 DT 6 DT 8 DT 10 DT 12 DT 14 DT 16
Nominal recirculation air flow m3/h 2500 2600 3000 4000 5000 6000 7000 10000 12000
Exhaust/fresh air flow (stepped control) m3/h 120-1200 130-1300 150-1500 200-2000 250-2500 300-3000 350-3500 670-6700 850-8000Total dehumidification @ 28oC/60% RH by heat pump and maximum fresh air
l/h 9.8 10.9 12.5 16.6 20.8 25.0 29.2 56.5 62.4
Heat to airVia heat pump (Mode B)Via standard LPHW @ 80oCVia upgraded LPHW @ 55°CTotal Mode B + standard LPHW
kWkWkWkW
3.82017
23.8
4.92219
26.9
5.12521
30.1
6.63026
36.6
8.03530
43.0
10.03832
48.0
12.14236
54.1
30.08572
115.0
35.09077
125.0Heat to pool waterVia heat pump (Mode A)Via LPHW @ 80oCVia LPHW @ 55°CTotal Mode A + LPHW
kWkWkWkW
4.02311
27.0
5.52311
28.5
5.83316
38.8
8.03316
41.0
10.03316
43.0
12.54020
52.5
15.04020
55.0
35.06532
100.0
43.06532
108.0Nominal power consumed kW 2.6 2.9 2.9 3.4 4.4 5.9 7.4 12.3 17.0
WidthDepthHeightWeight
mmmmmmkg
1740654
1685300
1740654
1685310
1840704
1970350
1840704
1970360
1840704
1970370
1840854
1970410
1840854
1970460
286011262120954
2860112621201020
P O O L A I R H A N D L I N G U N I T S
D E H U M I D I F I C AT I O N W I T H H E AT R E CO V E RY
96
Applications
�Leisure centres
�Olympic pools
�Hotel pools
�Wellness centres
�Health clubs
�Holiday parks & campsites
�School pools
Features
�Dynamic heat pump heat recovery to pool and air
�Self-regulating fresh air control
�Automatic control of exhaust air volume to match pool usage
�Free-cooling (HRD 15-20)
�Free-cooling and heat pump air cooling (HRD 25-30)
�Integral LPHW heat exchanger for air heating
�Double skinned insulated cabinet
�Bespoke fan specifications
Options
�Upgraded LPHW heat exchanger for air heating
�Left-hand or right-hand orientation
�Choice of supply fan outlet orientations
�Choice of fan static pressures
�BMS interface
H R D 30
Specifications Units HRD 15 HRD 20 HRD 25 HRD 30
Nominal recirculation air flowExhaust/fresh air flow (stepped control)Dehumidification @ 28°C/60% RH by heat pumpTotal by heat pump and maximum fresh air
m³/hm³/h
l/hl/h
120006000
3163
1950013500
45116
2500018000
68152
3500023000
88210
Heat to airVia heat pump (Mode B)Via standard LPHW @ 80°CMaximum available (Mode B + standard LPHW)Heat to waterVia heat pump (Mode A)
kWkWkW
kW
3770
107
40
55100155
60
72150222
95
90210300
117Cooling dutySensible Mode ASensible Mode B
kWkW
-20 -30
-49-30
-67-37
Nominal power consumed (dependent upon main fan duty) kW 17 23 31 44
P O O L A I R H A N D L I N G U N I T S
D E H U M I D I F I C AT I O N W I T H H E AT R E CO V E RY
97
TO
VE
NT
ILA
TE
D A N X 1/2/3 X D
Features
�Built-in user friendly control system for high-quality demand management. Automatic monitoring and control of temperature and humidity in the pool hall. Special developed software which always finds the most energy efficient way to run the unit under different conditions.
�Double crossflow heat exchangers with a high efficiency of more than 85% and a low pressure drop
�Built-in by pass for free cooling in summertime
�Highly efficient EC plug fans with low power consumption
�High efficient F5/F7 compact filters with large surface and low pressure drop
�Self-bearing cabinet with hot dip galvanised, powder painted sandwich panels with 50mm mineral wool insulation, internal partition walls with 30mm and bottom frame with adjustable feet
�The complete cabinet and internal components are specifically designed to withstand the aggressive swimming pool environment (Corrosion class C4 according to EN/ISO 12944-2), with epoxy coated crossflow heat exchanger, heating coil with aluminium frame, pre painted fins and epoxy coating with all fasteners, bolts and nuts specially protected
�Two large inspection doors with strong hinges and tongue locks and handles for easy access for service
�All-in-one box' solutions for easy and quick installation with all sensors and electrical components already connected
�BMS communication with either Modbus or BACnet
Applications
�Private pools
�Hotel pools
�Therapy pools
�Spa resorts
Specifications Units DANX 1 XD DANX 2 XD DANX 3 XD
Nominal air volumeMax. air volumeMax. external duct pressure*Outdoor air volumeDehumidification capacity VDI 2089**Max. total power consumptionPower supplyProduct size (h x w x d)Weight
m3/hm3/h
Pa%
kg/hkW
V/Hzmmkg
10001300350
0-1007
1.1230/1ph/50
1570 x 1750 x 515254
17502100350
0-100111.2
400/2ph/501570 x 1750 x 780
344
27503500350
1-100181.9
400/2ph/501990 x 2250 x 890
465
* at nominal air volume** at 30°C/54% indoor
P O O L A I R H A N D L I N G U N I T S
W I T H H E AT R E CO V E RY
98
D A N X X K S
Specifications Units 2/4 XKS 3/6 XKS 5/10 XKS 7/14 XKS 9/18 XKS 12/24 XKS 16/32 XKS
Nominal air volumeMax. air volumeOutdoor air volumeDehumidification capacity VDI 2089*Max. total power consumption**Power supplyHeightWidthDepthWeight
m3/hm3/h
%kg/hkW
V/Hzmmmmmmkg
335045000-100
222.2
400/3ph/5016003101880850
450060000-100
293.0
400/3ph/5019603572880925
8400100000-100
546.0
400/3ph/501960357214001300
12500140000-100
8111.0
400/3ph/502120
3712519001675
15500200000-10010015.0
400/3ph/502250408018001925
21500260000-10013922.0
400/3ph/502760427022002550
25500320000-10016560.0
400/3ph/503010510022003300
* at 30°C/54% indoor** at nominal air volume
Applications
�Hotel pools
�Therapy pools
�Spa resorts
�Municipal/commercial swimming pools
�Wellness centres
�Leisure centres
�Water parks
Features
�User friendly control system for high-quality demand management. Automatic monitoring and control of temperature and humidity of the pool hall.
�Crossflow heat exchanger with a high efficiency of more than 75% and a low pressure drop
�Built-in by pass for free cooling in summertime
�Highly efficient EC plug fans with low power consumption
�High efficient F5/F7 bag filters with large surface and low pressure drop
�Load bearing frame construction module with hot dip galvanised, powder painted sandwich panels with 50mm mineral wool insulation, internal partition walls with 30 mm and bottom frame with adjustable feet
�All modules and internal components are specifically designed to withstand the aggressive swimming pool environment (Corrosion class C4 according to EN/ISO 12944-2), with epoxy coated crossflow heat exchanger, heating coil with aluminium frame, pre painted fins and epoxy coating with all fasteners, bolts and nuts specially protected.
�Damper motors IP 66 specially designed for swimming pool environment
�Large inspection doors with strong hinges and tongue locks and handles for easy access for service
�Modular unit for easy and quick installation with all sensors and electrical components already connected. Separate control panel fitted with cables and plugs for quick electrical connection between unit and panel.
�BMS communication with either Modbus or BACnet
P O O L A I R H A N D L I N G U N I T S
W I T H H E AT R E CO V E RY
99
TO
VE
NT
ILA
TE
Applications
�Private pools
�Hotel pools
�Therapy pools
�Spa resorts
D A N X 1/2/3 H P
Specifications Units DANX 1 HP DANX 2 HP DANX 3 HP
Nominal air volumeMax. air volumeMax. external duct pressure*Outdoor air volumeDehumidification capacity recirculation**Dehumidification capacity VDI 2089**Power consumption compressor**Max. total power consumptionPower supplyProduct size (h x w x d)Weight
m3/hm3/h
Pa%
kg/hkg/hkWkW
V/Hzmmkg
10001300350
0-1001.77
0.61.7
230/1ph/501570 x 1750 x 515
279
17502100350
0-1005.0111.22.9
400/2ph/501570 x 1750 x 780
379
27503500350
1-1007.0181.94.6
400/2ph/501990 x 2250 x 890
500* at nominal air volume** at 30°C/54% indoor
Features
�Built-in heat pump with rotary compressor and high COP. Optional built-in water cooled condenser for heating of the pool or domestic water.
�Built-in user friendly control system for high-quality demand management. Automatic monitoring and control of temperature and humidity in the pool hall.
�Double crossflow heat exchangers with a high efficiency of more than 85% and a low pressure drop.
�Built-in by pass for free cooling in summertime.
�Highly efficient EC plug fans with low power consumption.
�High efficient F5/F7 compact filters with large surface and low pressure drop.
�Self-bearing cabinet with hot dip galvanised, powder painted sandwich panels with 50mm mineral wool insulation, internal partition walls with 30mm and bottom frame with adjustable feet.
�The complete cabinet and internal components are specifically designed to withstand the aggressive swimming pool environment (Corrosion class C4 according to EN/ISO 12944-2), with epoxy coated crossflow heat exchanger, coils with aluminium frame, pre painted fins and epoxy coating with all fasteners, bolts and nuts specially protected.
�Two large inspection doors with strong hinges and tongue locks and handles for easy access for service.
�All-in-one box' solutions for easy and quick installation with all sensors and electrical components already connected.
�BMS communication with either Modbus or BACnet
P O O L A I R H A N D L I N G U N I T S
W I T H H E AT R E CO V E RY A N D H E AT P U M P
100
Features
� Built-in heat pump with scroll compressor and high COP. Optional built-in water cooled condenser for heating of pool or domestic water.
� User friendly control system for high-quality demand management. Automatic monitoring and control of temperature and humidity of the pool hall.
� Crossflow heat exchanger with a high efficiency of more 75% and a low pressure drop
� Built-in by pass for free cooling in summertime
� Reversible heat pump (DanX XWPRS) with the possibility of active cooling in summertime.
� Highly efficient EC plug fans with low power consumption
� High efficient F5/F7 bag filters with large surface and low pressure drop
� Load bearing frame construction module with hot dip galvanised, powder painted sandwich panels with 50mm mineral wool insulation, internal partition walls with 30mm and bottom frame with adjustable feet
� All modules and internal components are specifically designed to withstand the aggressive swimming pool environment (Corrosion class C4 according to EN/ISO 12944-2), with epoxy coated crossflow heat exchanger, coils with aluminium frame, pre painted fins and epoxy coating with all fasteners, bolts and nuts specially protected.
� Damper motors IP 66 specially designed for swimming pool environment
� Large inspection doors with strong hinges and tongue locks and handles for easy access for service
�Modular unit for easy and quick installation with all sensors and electrical components already connected. Separate control panel fitted with cables and plugs for quick electrical connection between unit and panel.
� BMS communication with either Modbus or BACnet
Applications
�Hotel pools
�Therapy pools
�Spa resorts
�Municipal/commercial swimming pools
�Wellness centres
�Leisure centres
�Water parks
D A N X X W P S / X W P R S
Specifications Units 2/4 XWPS 3/6 XWPS 5/10 XWPS 7/14 XWPS 9/18 XWPS 12/24 XWPS 16/32 XWPS
Nominal air volumeMax. air volumeOutdoor air volumeDehumidification capacity recirculation*Dehumidification capacity VDI 2089*Max. power consumption compressorMax. total power consumption**Power supplyHeightWidthDepthWeight
m3/hm3/h
%kg/hkg/hkWkW
V/Hzmmmmmmkg
335045000-10010.1224.47.4
400/3ph/5016603665880
1150
450060000-10016.2295.7
10.1400/3ph/50
19604135880
1300
8400100000-10025.6548.8
16.8400/3ph/50
1960413514001800
12500140000-10033.981
12.023.0
400/3ph/502120427519002300
15500200000-10044.510016.031.0
400/3ph/502250466018002700
21500260000-10065.413924.046.0
400/3ph/502760495022003650
25500320000-10077.916530.060.0
400/3ph/503010586822002700
* at 30°C/54% indoor** at nominal air volume