POINTAX 6000MPoint recorder
GMC-I Messtechnik GmbH
3-348-798-034/8.18
ApplicationThe configurable point recorder POINTAX 6000M serves the recording of changing measured quantities. DC current, DC voltage, thermocouples as well as resistance thermometers (Pt 100) can be connected directly.Additionally, alphanumeric texts, date, time and events can be printed out.The recorder is meant for panel mounting.
Essential features• 6 measuring channels
• Last point visible from the front
• With text printout
• Measuring channels electrically isolated and earth-free
• Format 144 mm x 144 mm, mounting depth 250 mm
• Combined recording tablefor roll chart (32 m) or fanfold chart (16 m)
• RS 485 interface
• 2 limits per measuring channel
• Balancing
• 4 event markers
• Can alternatively be used as event recorder with 10 event markers
DescriptionThe POINTAX 6000M is a configurable point recorder, in scale version with 1 to 6 scale divisions.
The recorder is connected to transducers and/or directly to sen-sors like thermocouples or resistance thermometers.
The recorder is matched to the measuring task via the internal keyboard or via the serial interface with PC and parameterizing program PARATOOL P6000M.
Supplementary functions like text printout, date, time, balancing and event marker increase the information content of the print-out process quantity. Alarm signalling and remote control make the POINTAX 6000M a device to be used in a wide range of applica-tions.
The standby function makes triggered recording operation possi-ble.
POINTAX 6000MPoint recorder
2 GMC-I Messtechnik GmbH
Applied rules and standardsA) International standards
B) German standards
Symbols and their meaning
Technical specificationsAnalog inputs, nominal ranges
Analog inputs, measuring ranges
Lower range limit parameterizable from X1n ... X1n + 0.8(X2n – X1n) and
Range span parameterizable from 0.2(X2n – X1n) ... (X2n – X1n).
Deadband 0.25 % of the range spanSetting time 1 sLoad cycle time for all channels 3 ... 360 s selectableAttenuation of the measured value with low-pass filter of 1st order;Time constant 0 ... 60 s per meas. channel, parameterizable.Root-extract. funct. can be parameterized with DC current and
DC voltage measuring ranges.User-specific linearization
can be parameterized with DC current and DC voltage measuring ranges.
Reference conditions
Accuracy
Variations
IEC 484 DIN 43782 Potentiometric recorders
IEC 61010-1 DIN EN 61010-1 Safety requirements for electrical equipment for measurement, control and laboratory use Part 1: General requirements
IEC 664 VDE 0110 Insulation group
IEC 68-2-6 DIN IEC 68-2-6 Mechanical stress (vibrations)
IEC 68-2-27 DIN IEC 68-2-27 Mechanical stress (shock)
EN 60529 VDE 0470-1Test instruments and test procedures Degrees of protection provided by enclosures (IP code)
EN 61326-1 VDE 0843-20-1Electrical equipment for measurement, control and laboratory use – EMC requirements – Part 1: General requirements
IEC 721-3-3 DIN IEC 721-3-3 Climatic environmental conditions
IEC 742 DIN EN 60742 Classification VDE 0551 safety transformers
DIN 43802 Scales
DIN 16234 Recording chart
DIN 43831 Cases
Symbol Meaning
X1n / X1 Lower range limit nominal range / lower range limit
X2n / X2 Upper range limit nominal range / upper range limit
X2n – X1n / X2 – X1 Range span nominal range / range span
DC current 0...20 mA; Ri = 50 Ω4...20 mA; Ri = 50 Ω± 2.5 mA; Ri = 50 Ω
± 5 mA; Ri = 50 Ω± 20 mA; Ri = 50 Ω
DC voltage 0 ... 25 mV; Ri ≥ 2 MΩ± 25 mV; Ri ≥ 2 MΩ
0 ... 100 mV; Ri ≥ 2 MΩ± 100 mV; Ri ≥ 2 MΩ
0 ... 500 mV; Ri ≥ 2 MΩ± 500 mV; Ri ≥ 2 MΩ0 ... 2.5 V; Ri ≥ 200 kΩ
± .2.5 V; Ri ≥ 200 kΩ0 ... 5.0 V; Ri ≥ 200 kΩ
± 5.0 V, Ri ≥ 200 kΩ± 10 V, Ri ≥ 200 kΩ± 20 V, Ri ≥ 200 kΩ
Thermocouples,Ri ≥ 2 MΩ
Typ T –270 ... +400 °CTyp U –200 ... +600 °CTyp L –200 ... +900 °CTyp E –270 ... +1000 °CTyp J –210 ... +1200 °CTyp K –270 ... +1400 °CTyp S –50 ... +1769 °C
Thermocouples,Ri ≥ 2 MΩ
Typ R –50... +1769 °CTyp B 0 ... +1820 °CTyp N –20 ... +1300 °C
Cold junction compensation internally orexternally parameterizable
Resistance thermometerPt 100
With 2-wire connectionWith 3-wire connection
–50 ... +150 °C;–50 ... +500 °C;–200 ... +850 °CLine resistance 40 Ω max. Line resistance 80 Ω max.
Ambient temperature 25 °C ± 1 K
Relative humidity 45 ... 75 %
Auxiliary voltage Hn ± 2 %, nominal frequency ± 2 %
Mounting position Front upright ± 2°
Warm-up time 30 min
Deviation in acc. with DIN IEC 484 Class 0.5 referred to nominal range
With displacement of lower range limit and/or upper range limit additionally
± (0.1 % ×X2n – X1n – 0.1)X2 – X1
With internal cold junction compensation ± 4 K additionally
Temperature 0.2 % / 10 K, additionally0.1 % / 10 K with conn. to thermocouple
Humidity Note influence on recording chart in acc. with DIN 16234.
Auxiliary voltage Hn 0.1 % at 24 V DC/AC ± 20 %0.1 % at 24 V AC +10 % / –15 %0.1 % at 115 V AC +10 % / –15 %0.1 % at 230 V AC +10 % / –15 %
AC interf. volt. (see permiss. interf. volt.) 0.5 % of the range span
Magnetic field of ext. origin 0.5 mT 0.5 % of the range span
Mechanical stressin acc. with DIN IEC 68-2-6/27Transport Impact: 30 g/18 ms
Vibration: 2 g/5 ... 150 Hzin function Vibration:
0.5 g/± 0.04 mm/5...150 Hz/3 × 2 cycles
During and after the effect ± 0.5 % of the range span
POINTAX 6000MPoint recorder
GMC-I Messtechnik GmbH 3
Real-time clock
Function maintained in the case of power failure: 5 days (capac.).
Options (code H01)
Binary inputsNumber 6 (DI 1 ... DI 6)Auxiliary voltage 20 ... 24 ...30 V DC Input current 6 mAH signal 20 ... 30 VL signal 0 ... 1.3 V
Relay outputs6 potential-free relay contacts (roots connected to each other)Contact load: 30 V / 100 mA14 additional relays available via external I/O converter.
External speed changeIt is possible to switch between speed 1 and 2 and to switch the speed off, each via a freely selectable binary input.
Standby functionThe standby function is activated via a freely selectable binary input. Internal deactivation via limit monitoring is possible.
Event markers4 markers are possibleRecording at approx. 2 %, 5 %, 95 % and 98 % of the recording width.
Externally controlled recordingRecording of externally controlled channels.
10 event markersusable (without measured value recording) via external I/O con-verter (also see trend recording).
BalancingBalancing can be selected for each measuring channel. The external control of the balancing interval is via a freely selectable binary input.
End-of-chart signallingWith speeds of ≥120 mm/h, 2 hours before the chart runs out. With speeds of < 120 mm/h, at least 8 hours before the chart runs out. Signalling is via a relay contact which can be freely assigned. When changing the recording chart, enter the length of the chart roll into the recorder.
Limit monitoring2 limits per channel for monitoring the absolute value.6 internal relays can be freely assigned to the limits.Hysteresis 2 % of the range span (X2 – X1)
Display
Scale versionScale1 to 6 divisionsType size at number of divisions:
Channel displayby vertical LED column on the right side of the scale
Assignment scales to channelby vertical LED column on the left side of the scale
Display and control panel (behind the recording table)Display (only for parameterization) 5-digit 7-segment displayDigit size 4 × 7 mmOperation with 3 keys
Recording
Colorsviolet, red, black, green, blue, brownColor sequence in acc. with DIN 43838
Channel 1 violetChannel 2 redChannel 3 blackChannel 4 greenChannel 5 blueChannel 6 brown
or freely assignable to the channels
Last point visible from the frontColor reservoir ≥ 1 × 106 points per color
Trend recording
The measured value recording is carried out in the form of a point line with equidistant point space.
Operating modes
Cyclic operation – Processing all channelsRecording:
all channels are updated during the cycle timeMeasured value display:
a measuring channel switches continuously or channel-wise from cycle to cycle.
Externally controlledRecording:
the externally controlled channels are recorded, recording start can be delayed from 0 ... 30 s
Measured value display:switches channel-wise from cycle to cycle.
Option required
Cyclic operation – Processing one channelRecording and measured value display:
the displayed channel is updated during the cycle time.DO 1 ... DO 6 signals the measuring channel connected through.
Option required
Event recorder for 10 eventsRecording:
Start, duration and end of the event are recorded in the form of an open rectangle.
I/O converter required
Divisions 1 2 3 4 5 6
Type size (mm) 4 4 4 2 2 2
POINTAX 6000MPoint recorder
4 GMC-I Messtechnik GmbH
Text printout
only possible with chart speed ≤ 240 mm/h
Type size approx. 1.5 × 2 mm
Extent of the text printout:1. Ten text lines, each text line optionally with
up to 32 charactersup to 30 characters and time printoutup to 24 characters and time/date printout.Initiated cyclically, in parameterizable time intervals or depend-ing on events by internal limits or externally controlled (binary inputs).
2. Printout of chart speed, date and time.Initiated by switching on the recorder and by changing the chart speed.
3. Printout of current measured valuesInitiated cyclically, in parameterizable time intervals or depend-ing on events by internal/external control.
4. Printout of triple lines assigned to measuring points.First line: Scaling line with channel marking and printout of the unit of measurment.Second line: Measuring-point-specific text with up to 54 char-acters.Third line: Limit markings.
5. Printout of the balancing table consisting of:Comment lineStart and end time of the balancing intervalMin. / max. value during the balancing intervalAverage and cumulative value of the balancing interval
6. Lists of all active parametersInitiated manually in the parameterizing mode.
Chart roll speed
Auxiliary voltage
UC power supply24 V DC ± 20 %24 V AC +10 %, –15 %Power consumption at max. fitting approx. 15 W / 21 VA
AC power supply24/115/230 V AC +10 %, –15 %Frequency range 47.5 ... 63 HzPower consumption at max. fitting approx. 15 W / 21 VA
RS 485 interface
a) For parameterizationb) Coupling to higher order systems for bidirectional data transfer.
The data protocol follows the PROFIBUS standard.
Climatic suitability
Electrical safety
Test in acc. with DIN EN 61010-1 (Classification VDE 0411)and/or IEC 61010-1Protection class IMeasuring category
III at line inputII at inputs
Degree of pollution2 in the device and at the connecting terminals
Test voltage3.75 kV measuring channels to power supply2.20 kV protective conductor to power supply
Functional extra low voltage with protective isolation (PELV)
Between power input – measuring channels, control leads,interface cables acc. to VDE 0100-410 and VDE 0106-101
Electromagnetic compatibility
The protection goals of the EMC directive 2014/30/EU as to radio interference suppression and as to immunity to interference according to EN 61326-1 are complied with.
Speed parameterizable in mm/h 0/2.5/5/10/20/30/40/60/120/240/300/600/1200 to be switched over and off externally (Option)
Chart roll 32 m roll chart or 16 m fanfold chart
Visible diagram length 60 mm
Print span 100 mm(chart span 120 mm, DIN 16230)
Chart intake (for roll chart) via automatic chart take-up device (daily tear-off or take-up of the 32 m possible)
Ambient temperature 0 ... 25 ... 50 °C
Transport and storage temperature –40 ... +70 °C
Relative humidity (device in function) ≤ 75 % annual average, max. ≤ 85 %prevent dewing
Climatic class 3K3 in acc. with IEC 721-3-3
POINTAX 6000MPoint recorder
GMC-I Messtechnik GmbH 5
Factory settings
Scale with a division of 0 ... 100is supplied when no scale division is specified in the scale device order.
Parameter presettingsIf no individual parameterization is specified in the recorder order, the POINTAX 6000M is supplied with the following parameter pre-settings:
All measuring channels with the measuring range 0 ... 20 mASpeed 1: 20 mm/hSpeed 2: 120 mm/hThe limits are set to end values (0 and 20 mA).Attenuation of the measured value, zoom, print and limit func-tions are deactivated.No password is defined.This parameter presetting can be initialized again inde-pendently from the currently set parameterization.
Scope of delivery
1 copy of operating instructions2 fasteners1 roll chart or fanfold chart, inserted in the recorder1 color head
Additionally, depending on the order:reading ruler(s)
Connection, case and installationElectrical connections
Degree of protection IP 20Screw-plug terminals for measuring inputs, control inputs and limit value relay outputs.Max. wire cross section 2 × 1 mm2
Screw terminals for line connectionMax. wire cross section 1 × 4 mm2 or 2 × 1.5 mm2
RS 485 interface via 9-pole SUB D plugCase
Molded material for installation in panels or mechanical grids(see dimensional drawing for dimensions)
Degree of protection of the case in acc. with EN 60529Front (including door) IP 54Back IP 20
Color of the caseSilica-gray in acc. with RAL 7032
Door of the caseMetal frame (RAL 7032) with mineral glass or molded material
Fastening of the casewith 2 fasteners (optionally for installation in panel or mechani-cal grid) for a maximum grid width of 40 mm, centering angle brackets are required for installation in mechanical grids (Ordering number A416A)
Position of useInclined to the side [–30° ... 0 ... +30°], inclined to the rear 20°,inclined to the front 20°
Mounting distancehorizontal or vertical 0 mm, it must be possible to open the door of the case by 100°
Weight approx. 3.2 kg
Example of interlinking
POINTAX 6000M POINTAX 6000M
LINAX 4000H LINAX 4000M
Adapter setRS 485 / RS 232
Parameterizing software
or higher order systemsPARATOOL P6000M
POINTAX 6000MPoint recorder
6 GMC-I Messtechnik GmbH
Dimensional drawing (Dimensions in mm)
Panel cutout
1.0
14.5
RS 485 interfacePin 1: ScreenPin 3: RXD (+)Pin 5: Gnd (reference potential)Pin 6: +5 VPin 8: RXD (-)Pin 9: I/O converter (–)
For bus operation:The voltage +5 V at Pin 6 is required when the POINTAX 6000M is used as bus terminal.
The screen is put on a plug-in knife at the recorder case.
Wiring diagrams
CH1 013 012 011CH2 023 022 021CH3 033 032 031CH4 043 042 041CH5 053 052 051CH6 063 062 061
2-wire
3-wire
901 912 922 932 942 952 962
DI1– + + + + + +
DI2DI3
DI4DI5
DI6
801 812 822 832 842 852 862
D01D02
D03D04
D05D06
5 5 5 556 6
666
5 6
Binary inputsBinary input = depending on the parameterization for speed change, standby, event marker initiation, text printout
DI3
DI4
DI5
DI6
5 6
DI2
DI1
Measuring inputs Limit contacts
POINTAX 6000MPoint recorder
GMC-I Messtechnik GmbH 7
Order code (continued)
Description Article number
Point recorder POINTAX 6000M with universal signal inputs for process signals, thermocouples, resistance thermometers,display with analog scales, RS 485 interface, front dimensions 144 x 1444
A4260
Parameterization
Parameterization in accordance with presetting see page 5 Lower range limit X1 Upper range limit X2
Range is the same for all channels X1 = 0 mA X2 = 20 mA XH00
Parameterization in accordance with order code
within the listed limits (measuring ranges, texts, time, scaling line, options ...) XH92
Measuring range channel 1 XA9nn only in connection with XH92
Nominal range X1n X2n Lower range limit X1 Upper range limit X2
DC current 0 20 mA 0.0 ≤ X1 ≤ 16.0 mA X1 + 4.0 ≤ X2 ≤ 20 mA XA901
4 20 mA 4.0 ≤ X1 ≤ 16.8 mA X1 + 3.2 ≤ X2 ≤ 20 mA XA902
–2.5 2.5 mA –2.5 ≤ X1 ≤ 1.5 mA X1 + 1.0 ≤ X2 ≤ 2,5 mA XA903
–5 5 mA –5.0 ≤ X1 ≤ 3.0 mA X1 + 2.0 ≤ X2 ≤ 5,0 mA XA904
–20 20 mA –20.0 ≤ X1 ≤ 12 mA X1 + 8.0 ≤ X2 ≤ 20 mA XA905
DC voltage 0 25 mV 0 ≤ X1 ≤ 20 mV X1 + 5 ≤ X2 ≤ 25 mV XA906
–25 25 mV –25 ≤ X1 ≤ 15 mV X1 + 10 ≤ X2 ≤ 25 mV XA907
0 100 mV 0 ≤ X1 ≤ 80 mV X1 + 20 ≤ X2 ≤ 100 mV XA908
–100 100 mV –100 ≤ X1 ≤ 60 mV X1 + 40 ≤ X2 ≤ 100 mV XA909
0 500 mV 0 ≤ X1 ≤ 400 mV X1 + 100 ≤ X2 ≤ 500 mV XA910
–500 500 mV –500 ≤ X1 ≤ 300 mV X1 + 200 ≤ X2 ≤ 500 mV XA911
0 2.5 V 0 ≤ X1 ≤ 2 V X1 + 0.5 ≤ X2 ≤ 2.5 V XA912
–2.5 2.5 V –2.5 ≤ X1 ≤ 1.5 V X1 + 1.0 ≤ X2 ≤ 2.5 V XA913
0 5 V 0 ≤ X1 ≤ 4 V X1 + 1.0 ≤ X2 ≤ 5 V XA914
–5 5 V –5 ≤ X1 ≤ 3 V X1 + 2.0 ≤ X2 ≤ 5 V XA915
–10 10 V –10 ≤ X1 ≤ 6 V X1 + 4.0 ≤ X2 ≤ 10 V XA916
–20 20 V –20 ≤ X1 ≤ 12 V X1 + 8.0 ≤ X2 ≤ 20 V XA917
Continued on the next page
POINTAX 6000MPoint recorder
8 GMC-I Messtechnik GmbH
A4260
Thermocouple type B 0 1820 °C 0 ≤ X1 ≤ 1456 °C X1 + 364 ≤ X2 ≤ 1820 °C XA918
Thermocouple type E –270 1000 °C –270 ≤ X1 ≤ 746 °C X1 + 254 ≤ X2 ≤ 1000 °C XA919
Thermocouple type J –210 1200 °C –210 ≤ X1 ≤ 918 °C X1 + 282 ≤ X2 ≤ 1200 °C XA920
Thermocouple type K –270 1400 °C –270 ≤ X1 ≤ 1066 °C X1 + 334 ≤ X2 ≤ 1400 °C XA921
Thermocouple type L –200 900 °C –200 ≤ X1 ≤ 680 °C X1 + 220 ≤ X2 ≤ 900 °C XA922
Thermocouple type N –20 1300 °C –20 ≤ X1 ≤ 1036 °C X1 + 264 ≤ X2 ≤ 1300 °C XA923
Thermocouple type R –50 1769 °C –50 ≤ X1 ≤ 1405 °C X1 + 364 ≤ X2 ≤ 1769 °C XA924
Thermocouple type S –50 1769 °C –50 ≤ X1 ≤ 1405 °C X1 + 364 ≤ X2 ≤ 1769 °C XA925
Thermocouple type T –270 400 °C –270 ≤ X1 ≤ 266 °C X1 + 134 ≤ X2 ≤ 400 °C XA926
Thermocouple type U –200 600 °C –200 ≤ X1 ≤ 440 °C X1 + 160 ≤ X2 ≤ 600 °C XA927
Resist. thermometer 2-wire –50 150 °C –50 ≤ X1 ≤ 110 °C X1 + 40 ≤ X2 ≤ 150 °C XA928
Resist. thermometer 2-wire –50 500 °C –50 ≤ X1 ≤ 390 °C X1 + 110 ≤ X2 ≤ 500 °C XA929
Resist. thermometer 2-wire –200 850 °C –200 ≤ X1 ≤ 640 °C X1 + 210 ≤ X2 ≤ 850 °C XA930
Resist. thermometer 3-wire –50 150 °C –50 ≤ X1 ≤ 110 °C X1 + 40 ≤ X2 ≤ 150 °C XA931
Resist. thermometer 3-wire –50 500 °C –50 ≤ X1 ≤ 390 °C X1 + 110 ≤ X2 ≤ 500 °C XA932
Resist. thermometer 3-wire –200 850 °C –200 ≤ X1 ≤ 640 °C X1 + 210 ≤ X2 ≤ 850 °C XA933
Scale channel 1 without division FA001
same as measur. channel FA002
0 ... 100 FA003
as requested FA090
Reading ruler channel 1 without reading ruler GA001
same as scale GA002
0 ... 100 GA003
as requested GA090
Meas. range channel 2 same as meas. range channel 1, but markings XB... only in connection with XH92 XB9nn
Scale channel 2 same as scale channel 1, but markings FB... FBnnn
Read. ruler channel 2 same as channel 1, but markings GB... GBnnn
Meas. range channel 3 same as meas. range channel 1, but markings XC... only in connection with XH92 XC9nn
Scale channel 3 same as scale channel 1, but markings FC... FCnnn
Read. ruler channel 3 same as channel 1, but markings GC... GCnnn
Meas. range channel 4 same as meas. range channel 1, but markings XD... only in connection with XH92 XD9nn
Scale channel 4 same as scale channel 1, but markings FD... FDnnn
Read. ruler channel 4 same as channel 1, but markings GD... GDnnn
Meas. range channel 5 same as meas. range channel 1, but markings XE... only in connection with XH92 XE9nn
Scale channel 5 same as scale channel 1, but markings FE... FEnnn
Read. ruler channel 5 same as channel 1, but markings GE... GEnnn
Meas. range channel 6 same as meas. range channel 1, but markings XF... only in connection with XH92 XF9nn
Scale channel 6 same as scale channel 1, but markings FF... FFnnn
Read. ruler channel 6 same as channel 1, but markings GF... GFnnn
Further parameters deviating from the parameterization noneonly in connection with XH92
XP000
as requested, within the listed limits XP901
Continued on the next page
Order code (continued)
Description Article number
POINTAX 6000MPoint recorder
GMC-I Messtechnik GmbH 9
Ordering example
A4260 /XH92 /XA928 0 ... 100 °C / XB929 0 ... 300 °C / XC901 / XD901 / XE901 / XF901 /FA002 / FB002 / FC090 0 ... 50 l/s /FD090 0 ... 100 % FE003 / FF003 /GA001 / GB001 / GC001 / GD001 / GE001 / GF001 / H001 / P001 / J003 / K002
A4260
Options (binary inputs / binary outputs, limits, see page 3) No H000
Yes H001
Recording For roll chart (32 m) P001
For fanfold chart (16 m) P002
Auxiliary voltage 24 V ... 85 V AC/DC J001
95 V ... 240 V AC/DC J002
Front door Plastic K001
Metal K002
Label for measuring points Blank with GOSSEN METRAWATT logo L000
Blank without logo L001
With inscription as requested, 1 line / measuring point with up to 31 characters
L090
Test report None M000
With factory test certificate M according to DIN 55350-18-4.2.2 and reading test certificate B according to EN 10204-3.1B
M001
Operating instructions German N000
None N001
English N002
French N003
Italian N004
Point recorder POINTAX 6000M with universal signal inputs for process signals, thermocouples, resistance thermometers,display with analog scales, RS 485 interface, front dimensions 144 x 1444
A4260
Measuring range channel 1 Resist. thermometer 2-wire 0 100 °C XA928
Measuring range channel 2 Resist. thermometer 2-wire 0 300 °C XB929
Measuring range channel 3 DC current 0 20 mA XC901
Measuring range channel 4 DC current 0 20 mA XD901
Measuring range channel 5 DC current 0 20 mA XE901
Measuring range channel 6 DC current 0 20 mA XF901
Scale channel 1 same as measuring range FA002
Scale channel 2 same as measuring range FB002
Scale channel 3 0 ... 50 l/s FC090
Scale channel 4 0 ... 100 % FD090
Scale channel 5 0 ... 100 FE003
Scale channel 6 0 ... 100 FF003
Reading ruler channel 1 ... 6 Without reading ruler GA001 ... GF001
Options (binary inputs / binary outputs, limits) H001
Recording With roll chart (32 m) P001
Auxiliary voltage 230 V AC J003
Front door Metal K002
Order code (continued)
Description Article number
POINTAX 6000MPoint recorder
10 GMC-I Messtechnik GmbH
Accessories (continued)
Article numbers ending with a letter are complete and need not be commented.Article numbers ending with a numeral must be commented with the following texts.
Description Article number
RS232/RS485 Converter for top-hat rail mounting A403B
RS485 Cable for connection recorder converter (2x 9pole SUB-D plug) A420C
RS232 Cable for connection converter-PC (2x 9pole SUB-D plug) GTZ3241000R0001
Scale without division, beginning and end marked A429A
Scale, up to 6 divisions as requested A4300
Division Channel 1: without BA001
Division Channel 1: BA900
Division Channel 2: without BB001
Division Channel 2: BB900
Division Channel 3: without BC001
Division Channel 3: BC900
Division Channel 4: without BD001
Division 4: BD900
Division Channel 5: without BE001
Division Channel 5: BE900
Division Channel 6: without BF001
Division Channel 6: BF900
Reading ruler, 1 division as requested A4310
Division: AA900
Label for measuring points A4320
with GOSSEN METRAWATT logo AA000
without GOSSEN METRAWATT logo AA001
Channel 1 (violet) without inscription BA001
Channel 1 (violet) with inscription BA900
Channel 2 (red) without inscription BB001
Channel 2 (red) with inscription BB900
Channel 3 (black) without inscription BC001
Channel 3 (black) with inscription BC900
Channel 4 (green) without inscription BD001
Channel 4 (green) with inscription BD900
Channel 5 (blue) without inscription BE001
Channel 5 (blue) with inscription BE900
Channel 6 (brown) without inscription BF001
Channel 6 (brown) with inscription BF900
Continued on the next page
POINTAX 6000MPoint recorder
GMC-I Messtechnik GmbH 11
Screw terminal with 3 connectors A404B
Bus termination resistors A409A
Package with 2 × 390 ohms and 1 × 150 ohms
Z-diode combination Protection against interruption of unipolar and bipo-lar signals during plug-in module removal, for unipolar / bipolar inputs (4 each)
A421A
Consumable items (continued)
Article numbers ending with a letter are complete and need not be commented.Article numbers ending with a numeral must be commented with the following texts.
Description Article number
Recording chart, chart width 120 mm, recording width 100 mm
Roll chart 32 m, division 0 ... 100, min. ordering quantity 25 rolls
Time division / speed None A401A
10 mm/h A401B
20 mm/h A401C
60 mm/h A401D
120 mm/h A401E
as requested A4070
CA90
Roll chart 32 m, with calibrated division, min. ordering quantity 25 rolls A4071
Calibrated division as requested AA900
Inscription as requested BA900
Time division / speed as requested CA900
Fanfold chart 16 m, division 0 ... 100, min. ordering quantity 25 packages
Time division / speed None A401L
20 mm/h A401N
as requested A4075
CA90
Continued on the next page
Accessories (continued)
Article numbers ending with a letter are complete and need not be commented.Article numbers ending with a numeral must be commented with the following texts.
Description Article number
POINTAX 6000MPoint recorder
Edited in Germany • Subject to change without notice • A pdf version is available on the internet
GMC-I Messtechnik GmbHSüdwestpark 1590449 Nürnberg • Germany
Phone +49 911 8602-111Fax +49 911 8602-777E-Mail [email protected]
Fanfold chart 16 m, with calibrated divis., min. ordering quantity 25 packages A4074
Calibrated division as requested AA900
Inscription as requested BA900
Time division / speed as requested CA900
Print head A405B
Consumable items (continued)
Article numbers ending with a letter are complete and need not be commented.Article numbers ending with a numeral must be commented with the following texts.
Description Article number