PNMT(PASOLINK+ STM0)

download PNMT(PASOLINK+ STM0)

of 82

description

CONFIG

Transcript of PNMT(PASOLINK+ STM0)

ROI-S04451-055E030526PN MTASOLINKETWORKOperation ManualPASOLINK+ (SDH/STM-0) versionANAGEMENTERMINALNEC CorporationCopyright 2003ROI-S04451Table of Contents1. GETTING STARTED ...................................................................................................................... 11.11.21.3INTRODUCTION .......................................................................................................................... 1CONVENTIONS USED IN THIS MANUAL ..................................................................................... 11.1PNMT COMMUNICATION INTERFACES ................................................................................ 21.3.1Communications ....................................................................................................... 21.41.5HARDWARE CONFIGURATION FOR MOBILE TERMINAL (PNMT) ............................................... 4SOFTWARE CONFIGURATION FOR MOBILE TERMINAL (PNMT)................................................. 42SYSTEM OPERATION & MAINTENANCE .............................................................................. 52.12.22.3THE PNMT SCREEN ................................................................................................................. 5LAUNCHING THE PNMT APPLICATION...................................................................................... 7LOGIN ........................................................................................................................................ 82.3.1User Privilege ...........................................................................................................92.42.52.62.72.82.92.102.112.12LOGOUT ................................................................................................................................... 10SHUTTING DOWN THE PNMT ................................................................................................. 10SEARCHING FOR NETWORK ELEMENTS AND CONNECTING TO SELECTED PASOLINK ............. 11CHANGE PASSWORD ................................................................................................................ 12ALARM BUZZER SETTING ........................................................................................................ 13REFRESH ................................................................................................................................. 14REMOTE VIEWING PNMT(LINK SUMMARY) WINDOW ............................................................ 15OVERALL TAB .......................................................................................................................... 16ODU TAB ................................................................................................................................ 182.12.1 ODU tab .................................................................................................................. 182.13 IDU TAB ................................................................................................................................. 202.13.1 IDU Tab................................................................................................................... 202.14 CLK TAB ................................................................................................................................. 232.15 AUXILIARY I/O TAB ................................................................................................................. 242.15.12.15.22.15.32.15.4Monitored Items ..................................................................................................... 25Optocoupler Input Setting...................................................................................... 25Relay output Setting............................................................................................... 26Relay Configuration................................................................................................ 262.16 VERSION TAB .......................................................................................................................... 282.16.1 Version Monitor ...................................................................................................... 282.17 CONTROL (CTRL) TAB ............................................................................................................ 302.17.12.17.22.17.32.17.42.17.52.17.6The Control Module ................................................................................................ 30Setting the Date/Time ............................................................................................ 30CPU Reset ...............................................................................................................31Downloading the Configuration Files to the Control Module............................... 32Downloading a new Program File to the Control Module .................................... 34Uploading Control Module Configuration file to PNMT PC................................. 352.18 MAINTENANCE ........................................................................................................................ 362.18.12.18.22.18.32.18.42.18.52.18.62.18.7Maintenance menu ................................................................................................. 37Selecting Maintenance mode ................................................................................. 38Switching TX (for 1+1 system only) ....................................................................... 38Switching RX (for 1+1 system only)....................................................................... 38Main Signal Loopback ............................................................................................ 39IF Loopback (local only loopback) .......................................................................... 40ALS Restart ............................................................................................................ 40- i -ROI-S044512.18.8 Lockout Control ...................................................................................................... 412.18.9 Source Select Control ............................................................................................. 422.18.102.18.112.18.122.18.132.18.142.18.15Clear WTR Timer .................................................................................................. 42Selecting TX Mute status...................................................................................... 43TX Frequency ........................................................................................................ 43RX Frequency ........................................................................................................ 43Selecting Carrier Wave status .............................................................................. 44ATPC Manual ........................................................................................................ 442.19 EQUIPMENT SETUP ................................................................................................................. 452.19.12.19.22.19.32.19.4Equipment Configuration Window ........................................................................ 45Setup ....................................................................................................................... 46Editing the NE Name ............................................................................................. 47Editing the Note for CTRL ..................................................................................... 472.20 PROVISIONING ......................................................................................................................... 482.20.12.20.22.20.32.20.42.20.52.20.6Provisioning Window .............................................................................................. 48MAIN INTFC .......................................................................................................... 49Overhead (OH) Assignment ................................................................................... 55Manual Transmit Power Control (MTPC) Status ................................................. 56Automatic Transmit Power Control (ATPC) Status .............................................. 58SW priority.............................................................................................................. 612.20.6.1 TX SW Priority ...................................................................................................... 612.20.6.2 RX SW Priority ...................................................................................................... 612.20.7 Sub INTFC .............................................................................................................. 622.20.8 BER Threshold........................................................................................................ 632.21 LINK PERFORMANCE MONITOR ............................................................................................... 702.21.12.21.22.21.32.21.42.21.52.21.62.21.72.21.82.21.9Viewing Summary Link Performance Monitor ..................................................... 70Threshold setting .................................................................................................... 71Link Performance Monitor (Daily Data) window. ................................................. 72Link Performance Monitor (15 min Data) window ............................................... 73Section Trace ...........................................................................................................73Section Trace J0 (MUX).......................................................................................... 75Section Trace J0 (DMR).......................................................................................... 75Section Trace J1 (MUX).......................................................................................... 76Section Trace J1(DMR)........................................................................................... 762.21.10 Section Trace J2..................................................................................................... 772.21.11 Signal Label ...........................................................................................................772.22 EVENT LOG .............................................................................................................................. 792.21.1 Event log monitor ...................................................................................................... 79- ii -ROI-S044511.1IntroductionThe PNMT is a Pasolink Network Management Terminal developed by NEC for managementof NECs Pasolink and Pasolink+ radio transmission network. The PNMT is a scaled down version of Pasolink Network Management System (PNMS) that is designed as a maintenancetool for field engineers to locally and remotely monitor alarms, control points, generate repots, and archive data, all within a familiar graphical user interface, and all in real time. The PNMT is a Mobile laptop computer fitted with NEC PNMT software package that interfaces andcontrols NEC PASOLINK series short haul radio equipment.This Windows-NT/98 based software package remote monitors and controls the status and configuration of an entire PASOLINK network with associated equipment as well as the performance of the actual microwave links.1.2Conventions Used in this Manual- 1 -FontWhat the Font RepresentsExampleItalicFor manual titles or related document names.Please refer to Pasolink OperationManual for details.HostnameBoldItems on the user interface. Items on the computer display.File and directory names.The Overall window [Button]Buttons on the user interface.Click on [OK] button to continue Click on [Execute] button to send command.Menu ItemsA menu name followed by a colon (:) means that you must select the menu and then item.When the item is followed by an arrow(-> ), a cascading menu follows.Select System -> Login/Logout

A command variable where the user must enter the appropriate value.This is also commonly used when asking for a password.

KeycapKeyboard keys.Press Enter key.1. Getting StartedROI-S044511.31.1PNMT Communication Interfaces1.3.1CommunicationsCommunications between the PNMT and the radio network equipment can bevia the PNMT Port of the Pasolink equipment, via the DSC to a remote node in the network.1.3.1.1 PNMT Port InterfaceOn the Pasolink equipment, the PNMT Port is located on the front of theequipment.ODUThe PNMT Port consists of an RJ-45 connector and connects to ControlModule(CTRL) installed in the IDU via a serial cable to the relevant communications port of the PNMT Computer.The PNMT Port has the following properties: Port Configuration: Connector type: Bit per second rate: Stop bits: Data bit length: Parity:RS-232RJ-45 modular jack1200/2400/4800/9600/19200 (default 19200)18no parity.- 2 -Fig. 1: Connecting the PNMT to Pasolink+ IDUIDU PNMT portPasolink+ IDUPNMT CablePNMTROI-S04451The following table is the pin assignment of the connection between the IDUPNMT Port and PNMT PC.- 3 -PNMT(PC) to Pasolink+ (PNMT port)3M9pin(F) RJ45Pasolink+ PC (PNMT) PNMT portRS-232C RS-232C1 DCD 1 1 1 CD2 RXD 2 2 2 TXD3 TXD 3 3 3 RXD4 DTR 4 4 4 DSR5 GND 5 5 5 GND6 DSR 6 6 6 DTR7 RTS 7 7 7 CTS8 CTS 8 8 8 RTS9 RI 9Cabling diagram between PNMT PC and PNMT portROI-S044511.4Hardware Configuration for Mobile Terminal (PNMT)Recommended PNMT mobile PC configuration:Laptop PC with TFT DISPLAY (IBM PC or compatible)CPU:RAM: HDD:FDD:Pentium-400 or higher128 MB or more2 GB or more3.5 x 1CD-ROM:8 X or higherDisplay: 800x600 Screen area (16-bit color)Integrated Sound Card + Speaker1.5Software Configuration for Mobile terminal (PNMT)All structured and modular programs used in PNMT are resident in the hard disk and RAM of the personal computer. The Windows operating system is employed which is capable of multi-task processing using the Pentium microprocessor. The PNMT software basically consist of two parts, the operating system and the application programs .The operating system-Windows 98 (English Version) or-Windows NT Workstation Ver4.0 (English Version)-Windows 2000 (English Version)The application programs-PNMT softwareOther applications:-Internet Explorer 5.0 or higher-Acrobat Reader (to read Help File with PDF)- 4 -ROI-S04451This chapter explains the menu structure and procedures for operating of the PNMT. Theexplanation uses typical PNMT screens to illustrate the hierarchy of menu.2.1 The PNMT ScreenThe PNMT window is comprised of the following main parts (Refer to figure 1).For detailed descriptions, refer to the Users Manual for the Windows NT operating system.Title barThe title bar of the window is used to indicate the title of the window.oCommon Menu barThe common menu bar of the window presents the System and Help options, illustrates the commands that can be executed from the various options. The Help function also can display the html version of this operation manual.oNE-specific Menu barThis menu is a list of tasks that can be performed to the specific network element(NE) displayed in the PNMT. Configuration, Event Log, and Link PerformanceMonitor functions can be executed in the NE-specific Menu bar.oBlock DiagramThe block diagram illustrates the equipments of the Pasolink Radio system. Its main purpose in the window is to display the current summary alarm state of theequipment. You can click on a specific block to display the status of equipment in the data window.ooData windowThis window displays in detail the status and alarm items of a specific equipment of the NE. You can select the tab or the block of the specific equipment you want to monitor in the data window.TabsTo view the status and alarms in the Pasolink radio, click on the tab at the bottom of the Data window.oCommand ButtonThe command button is used to enter the data selected on the pop-up window into the computer.ooSelectable FieldThe selectable field is a standard Windows input field where the user can scroll down on a list of values available for that option.Login UserThis indicates the current user that logged-in in the PNMT.o- 5 -2 System Operation & MaintenanceROI-S04451Title BarNE-Specific Menu BarBlock DiagramCommonMenu BarCommonTool BarDataWindowTabsLogin UserSelectable FieldCommand ButtonFig. 1: Common Parts of a Window- 6 -ROI-S044512.2Launching the PNMT application.To start PNMT:1.Power ON the system.NOTEConnect the RS-232C cable 30seconds after IDU'spower is ON make sure that the RS-232C cable is connected between Com 1 of the PNMT PC and thePNMT Port of the IDU.2.Login to Windows 2000/NT/98 Workstation. Please refer to Windows2000/NT/98 Manual.3.Click on Start -> Programs -> Pnmt -> Pnmt then PNMT system logo appearsfollowed by the PNMT(Link summary) window in the PNMT main window (See figure below)- 7 -ROI-S044512.3LoginUsers are registered by means of login name and password.To protect the network and network management system from unauthorized access orunauthorized modifications, five levels (refer to the table shown in section 2.3.1 User Level Privilege) of users are defined with different privileges. The functions are available in the window depending on the users access level. Therefore, some of the functionsmay or may not be carried out.The highest level or administrator level has full access to the network and networkmanagement system and has the ability to create and assign privileges to other users.To login:1. Click on System -> Login/Logout in the Menu bar on main window.2. Enter the User name.3. Enter the valid Password for the specific User.4. Click on the [OK] button.- 8 -ROI-S044512.3.1User Level PrivilegeUser Privilege (STM-0)- 9 -54321CategoryITEMMonitorUserLocalRemoteAdminSYSTEMALARM BUZZEROOOOCONNECT(Remote Login)OOPROVISIONINGMTPCMTPC TX POWEROOORX THRESHOLD LEVELOOOADDITIONAL ATTOOOATPCATPC MAXIMUMOOOATPC MINIMUMOOORX THRESHOLD LEVELOOOADDITIONAL ATTOOOTX POWER CONTROL onODU CPU ALM MODEOOOBER ALMTHRESHLD(RADIO)HIGH BER(RADIO) THRESHOLDOOORX SWITCH(RADIO) THRESHOLDOOOBER ALMTHRESHLD(DMR)B1 E-BER(DMR) THRESHOLDOOOB1 SD(DMR) THRESHOLDOOOB2 E-BER(DMR) THRESHOLDOOOB2 SD(DMR) THRESHOLDOOOB3 E-BER(DMR) THRESHOLDOOOBER ALMTHRESHLD(MUX)B1 E-BER(MUX) THRESHOLDOOOB1 SD(MUX) THRESHOLDOOOB2 E-BER(MUX) THRESHOLDOOOB2 SD(MUX) THRESHOLDOOOB3 E-BER(MUX) THRESHOLDOOOMAIN INTFCALSOOOALS DELAY TIMEOOOMAIN CHANNEL ASSIGNMENTOOOCH-? SETTINGOOOMAIN CHANNEL USAGE VC12-?OOOAIS ACTIVATION CONDITIONOOOMS RDI ACTIVATION CONDITIONOOOAIS SEND (LOOPBACK-1)OOOAIS SEND (LOOPBACK-2)OOOCHANNEL USAGE ERROROOOJ0 DETECT MUX/DMROOOJ1 DETECT MUX/DMROOOCLK PROVISIONINGOOOSUB INTFCSUB INTFCOOOWS INTFCOOOWS LINE LENGTHOOOOH ASSIGNMENTASSIGNMENTOOOCHANNEL USAGEOOOV11-? DIRECTIONAL SETTINGOOOSW PRIORITYTX SW PRIORITYOOORX SW PRIORITYOOOMAINTENANCEMAINTOOOOTX/RX FREQUENCYOOOTX SWITCHOOOTX MUTEOOOIF LOOPBACKOOOMAIN SIGNAL LOOPBACK-1OOOMAIN SIGNAL LOOPBACK-2OOOMAIN SIGNAL VC12-? LOOPBACK-1OOOMAIN SIGNAL VC12-? LOOPBACK-2OOOCWOOOALS RESTARTOOOATPC MANUAL CONTROLOOORX SWITCHOOOCLK LOCKOUT CONTROLOOOCLK SOURCE SELECT CONTROLOOOCLK CLEAR WTR TIMEROOOEQUIPMENT SETUPEQUIPMENT SETUPOOONE NAMEOOONOTEOOOOAUX I/OINPUTOOOOOUTPUTOOOORELAY CONFIGURATIONOOOOPMONPMONPMON ThresholdOOOOSave to diskOOOOSECTION TRACEPATTERN SETTINGOOOOSave to diskOOOOEVENT LOGSave to diskOOOOCTRLCONTROLDATE/TIMEOOODOWNLOADCONFIGURATION FILEOPROGRAM FILEOUPLOADCONFIGURATION FILEOCPU RESETRESETOOO*Admin : Enable to access to the all Network Elements.*Remote : Enable to access to the all Network Elements.(Disable to change network configuration and change program with downloading.)*Local : Enable to access to the Local NE and Opposite NE.(Disable to change network configuration and change program with downloading.)*User : Enable to access to items which doesn't affect to the equipment.*Monitor : Enable to monitor only and disable to control.ROI-S044512.4LogoutTo logout from PNMT:1.Click System -> Login/Logout on the Menu bar on the main window.2.Select Logout from the Login /Logout window.3.Click on [OK] button to continue the Logout process.2.5Shutting Down the PNMTTo close the PNMT application:1.Click System -> Exit on the Menu bar on the main window2.Click [Yes] to confirm closing the application.- 10 -ROI-S044512.6Searching for Network Elements and Connecting to Selected PasolinkThe summary description (Pasolink name, Equipment type, Opposite Pasolink, etc.) of the current station where PNMT is connected can be displayed using this function. Summary description of the opposite station belonging to that link is also displayed.To search for or connect to Pasolink in the network:1. Click on System -> Connect on Menu bar on main window.NOTEInitially only the current NE physically connected tothe PNMT and its opposite station will be shown on the Network Element List.2.Click on [Search for Element] button to display all connected NEs in the network.3.Select and highlight the NE to be viewed.4.Click [Connect] button. The PNMT(Link Summary) of the Pasolink selected and itsopposite station will be displayed.- 11 -ROI-S044512.7Change PasswordTo change the password:1.Click on System -> Change Password on the Menu bar on main window.Enter the Old password.2.Enter New Password3.Enter new password on the Confirm New Password to confirm.4.Click on [OK] button.NOTEFor details on initial user name and password,please refer to PNMT Install manual.- 12 -ROI-S044512.8Alarm Buzzer SettingThis function is used to activate and set the Alarm Buzzer. The desired sound scheme can also be set using this function.To set the Alarm Buzzer:1. Click System |Alarm Buzzer in the main window.2.Select the Wave file or Beep box to activate the buzzer. No sound is the factorysetting of the PNMT.3.If you select the Wave file box, Enter the location of the sound file (*.wav)Otherwise; click on [] to locate the desired file. You can also preview the *.wav file by click on the arrow next to the browse button.If you select the Beep box, Click on [Edit] to edit the beep with its frequency and duration. You can also preview the Beep by click on the arrow next to the browsebutton.4.Click on [OK] button to activate the new setting.- 13 -ROI-S044512.9RefreshThis function is supported only by PNMT. This function enables PNMT to acquire all status manually and to update equipment informationTo Refresh:Click on Refresh Refresh in the main window or click on the refresh icon in the toolbar.NOTEMetering items such as TX power, RX level, powersupply and BER are automatically refreshed every 15 seconds. This function is used when the immediate refreshing of these metering items is necessary or confirmation of all current status is immediately required.- 14 -ROI-S044512.10 Remote Viewing PNMT(Link Summary) WindowYou can view a target link within the one Root NE cluster of the Pasolink network by searching the connected NEs and then connecting to a target NE. Please refer to Section 2.6 Searching for Network Elements and Connecting to Selected Pasolink. This function allows you to connect to any NE in the network remotely.NOTE: For multi-Root NE network, you can only connect to NEs that are being polledby the same RootNE as the local NE where you are directly connected via the PNMTcable.PNMT (Link Summary) window (1+0 configuration)- 15 -ROI-S044512.11 Overall TabThis tab is displayed on startup. The overall tab provides a snapshot at the most significant monitored items in the NE.Overall Tab for(1+0 configuration)Overall Tab for(1+1 Twin-Path configuration)Overall Tab for(1+1 Hot-standby configuration)The Overall tab gives a snapshot of the important settings of the NE. This window onlydisplays current settings and there are no control functions associated with this window.- 16 -ROI-S04451The following items are displayed in this tab:MTPC TX Power the current value (in dB) of the Manual Transmitter PowerControl attenuation set in the ODU. The MTPC Attenuation will only have a valid data if the MTPC is enabled.ooTX Frequency the current transmit frequency used.oRX Frequency the current receive frequency used.Frame ID the set frame ID of the NE.oTX Power Control shows the current power control mode used by the ODU. TheTX Power Control is either Automatic Transmitter Power Control (ATPC) or ManualTransmitter Power Control (MTPC).oMAIN INTFC shows the current main interface used by the IDU. The availableinterfaces are: STM-1(Electrical), STM-1(Optical)and 21CH*2BoALS shows the current setting of the Automatic Laser Shutdown (ALS). It caneither be Enable or Disable. The ALS is an IDU function that intermittently turns on/off the laser output when a certain period elapses after STM-1 LOS mode starts.ooMAINT the current state of the Maintenance status.Selected TX (for Hot-standby configuration only) shows the current system usedfor signal transmission.oSelected RX (for 1+1 system only) shows the current system used for signalreception.o- 17 -ROI-S044512.12 ODU TabThis function is to display the values and status of the monitored items of the ODU. This window only displays current settings and there are no control functions associated with this window.To set the ODU parameters see the chapters on Equipment Setup and Provisioning.2.12.1 ODU tabTo view the alarm and status display of the ODU:1.Click the ODU tab in PNMT(Link Summary) window of the target NE.1+0 ODU windowODU window(1+1 configuration)- 18 -ROI-S04451Monitored Items in the ODUFollowing items are monitored.TX PORTIONAlarmoTX INPUT: alarm occurs when the TX IF input signal from the IDU is lostoTX POWER: TX RF Power decreases 3 to 6 dB from nominal value.ATPC Status(This portion of screen is only active ifATPC is used.)Control Range*RX Threshold Level* Additional Attenuation*ODU ALM Mode*oo o oMeteringTX Power: The transmitted power of theODU in dBm.MTPC Status(This portion of screen is only active ifMTPC is used.)o MTPC TX Power *o RX Threshold Level*o Additional Attenuation*RX PORTIONAlarmRX LEVEL: alarm occurs when the input level decreases by preset value from squelch level. (See Provisioning : RX Threshold)MeteringRX Level: The received level interpreted in dBm.COMMON PORTIONAlarmo APC this alarm occurs when the Local Oscillator is locked out.o CABLE this alarm occurs when the communication between the ODU and the IDUis lost.MeteringPower Supply: Display PS value (V)* For the detailed description of this items see 2.16 Equipment Setup and 2.17Provisioning.- 19 -ROI-S044512.13 IDU TabThis function is to display the values and status of the monitored items of the IDU. This window only displays current settings and there are no control functions associated with this window.To set the ODU parameters see the chapters on Equipment Setup and Provisioning.2.13.1 IDU TabTo view the alarm and status of the IDU:1. Select the IDU tab in PNMT(Link Summary) window of the target NE. The figurebelow illustrates the difference between the IDU tab of a 1+0 and a 1+1 system. Only the TX, RX and Common portion is different for both systems.IDU window (1+0 configuration)- 20 -Displayed at 2M INTFC onlyROI-S04451IDU window (1+1 configuration)- 21 -Displayed at 2M INTFC onlyROI-S04451Monitored ItemsFollowing items are monitored:MODULEAlarmo MAIN INTFC - alarm occurs whenMain INTFC module fails.oSUB INTFC - alarm occurs when the SUB INTFC fails.oMODEM - alarm occurs if there is a modem failure.oPS - alarm occurs if there is a DC-DC CONV failure. (for 1+1 systems only)TX & RXAlarmMOD - alarm occurs when the TX unit(modem) failed.DEM - alarm occurs when the RX unit (demodulator) fails or the IF signal is lost HIGH BER - alarm when BER is worse thanpreset value. (for 1+1 systems only)MDCPU - alarm when there is a failure in the communication between modulesSw StatusSelected (for 1+1 systems only)COMMON PORTIONSUB INTFCMeteringBER: The current overall value of the Bit-Error- Rate(B1)AlarmLOS - loss of signal occurredAIS RCVD - Indicates reception of the AIS code in each 2Mbps data stream from the MUXMUX & DMRLOP - loss of pointer occurredPLM - detects Payload MismatchLOM - Loss of Multi-frame occuredAIS - Alarm Indication Signal (MUX only) UNEQ - detects Unequipped conditon RDI receives Remote Defect IndicationLOS - loss of signal occurredLOF - loss of frame occurredTIM - detects Trace Indication MismatchE-BER - BER portion is worse than E-BERthreshold.SD - BER is worse than the Signal Degrade thresholdSPI/RST - SDH Physical Interface/Regenerator Section TerminationMST - Multiplex Section TerminationMSA - Multiplex Section AdaptationHPA - Higher order Path AdaptationC: Common between MUX and DMRHPT - Higher order Path TerminationPPI - PDH Physical Interface MUX onlyM: MUX onlyTable of Displayed Alarm with MUX and DMR- 22 -LOSLOFTIME-BERSDLOPPLMLOMAISUNEQRDISPI RSTCCCCC------MST---CC---M-CMSA(AU)-----C--M--HPT--CC-----CCHPA------CC---PPIM-------M--ROI-S044512.14 CLK TabThe function of each control is as follows.CLKLoss of Timing InputSignal Fail (EQUIP)- alarm occurs when all clock source are lost.- alarm occurs when each clock source is in the failed condition.- alarm occurs when each clock source is in the failed condition. (applies only when an external clock is used and the Selected External Output provisioning item has been set to Line.)- indicates the clock that has been selected for the equipment timing source.- indicates the line clock selected for the external clock output. (applies only when an external clock is used and the selected External Output provisioning item has been set to Line.)- indicates the availability of each applicable clock source.- indicates the quality level of each applicable clock source.- indicates whether the associated clock source that is now back to normal condition is in the wait to restore state.- indicates the reception of the AIS code in the 2 Mbps signal fed to the EXT IN port. (applies only when a 2Mbps signal is used as an external clock source)- Indicates whether the operating mode of the equipment clock is Freerun state or not.- Indicates whether the operating mode of the equipment clock is Holdover state or not.- Indicates the status of the external clock signal supplied by the EXT OUT port.- indicates that the manual clock switching operation performed by the user has been rejectedSignal Fail (Line)CLK Selected (EQUIP)CLK Selected (Line)Signal AvailableInterpret QL MONWait To RestoreAIS RCVDOperation Mode (Freerun)Operation Mode (Holdover)Squelched External OutputExternal Command RejectEQUIP (equipment):Line:The EXT CLK output is derived from the PLL.The EXT CLK output is derived from a CLK extracted from an STM signal (MUX/DMR CLK)- 23 -ROI-S044512.15 Auxiliary I/O Tab4-relay output and 6 optocoupler inputs are provided in the PNMT for external control and alarms. The setting for each relay output/optocoupler is available by clicking on the selected device in the Auxiliary I/O Monitor window.To monitor and set the Auxiliary I/O:1. Select the Aux. I/O tab in the PNMT(Link Summary) window- 24 -ROI-S044512.15.1 Monitored ItemsFollowing items are monitored in this tab:1. Six (6) inputs (Input1 - Input6)2. Four (4)-relay outputs. (Output1 - Output4)2.15.2 Optocoupler Input SettingTo set the Optocoupler input:1.Click on the selected [Input-n] button in Aux. I/O tab.2.The input properties will be displayed in the ensuing window.2.15.2.1 Setting the selected Input to Alarm or Status1.Select the Alarm condition of the Input. You can select the event when thetarget Input will send the alarm signal to the PNMS/PNMT. Also you canpreset the input to just send the Status of the input instead of an alarm signal. The alarm input severity is defined in the X.733 recommendations. Select theSeverity of the alarm, its type and probable cause by clicking on the pull-down arrow on the left-hand side of the field.2.Click on the Name tab.3.Enter the name of the Input in the Name, Event ON, and Event OFF field. Amaximum of 32 characters can be used4.Click on [Execute] button to activate the selected state of the device.5.Click on [Close] button when finished.- 25 -ROI-S044512.15.3 Relay output SettingTo set the relay output:1.Click [Output-n] button in Aux. I/O window.2.To open or close the relays click on the Event ON or Event OFF buttonrespectively.3.Enter the desired strings for the open and close states of the Relay in theappropriate Even ON and Event OFF fields. A maximum of 32 characters can be used.4.Enter the desired name on the Name field. A maximum of 32 characters can beused.5.Click on [Execute] button to carry out the command.6.Click on [Close] button when finished.2.15.4 Relay ConfigurationThere are 11 relays in the Pasolink+ IDU. Consequently, 11 parallel alarms can bedefined. Relays RL01, RL02 and RL03 have fixed alarms. Maintenance, PS ALM andCPU Alarm are outputted on RL01, RL02 and RL03 respectively.RL04 to RL11 are user-definable relays. If the HK-OUTs are enabled, RL08 to RL11 areallocated for Housekeeping (HK) alarms.The PNMT allows the user to configure the relays in a table format. The columnsindicate the relays (RL01 to RL11) and the rows indicate the parallel alarms available in the Pasolink+ IDU. The following indicators are used in the table: Out indicates that the alarm - in the corresponding row, is issued on thecorresponding relay. HK Indicates that the corresponding relay is used for House Keeping.Mask Indicates that no alarm is issued in the corresponding relay when the maintenance mode is activated. Blank button not related to the corresponding alarm.- 26 -ROI-S04451To set the relay configuration:1.Click [Relay Configuration] button in Aux. I/O window.2.Select the HK-OUT used in the IDU. There are four (4) available HK-OUTs in thePasolink+ system. Selecting 1/2/3/4 button means all HK-OUTs will be enable; 1/2/3 means only HK-OUT 1, 2 and 3 will be enabled; and so on. If the HK-OUTs will not be used, select Disable button.3.Click on the button(s) that corresponds to the target alarm(s) and relay (s).4.Click on [Execute] button to apply the new relay configuration.5.Click on [Close] button when finished.- 27 -ROI-S044512.16 Version TabThe inventory information of the ODU and IDU can be viewed using this function.2.16.1 Version MonitorTo display version of ODU and IDU.1.Select the Version tab in PNMT(Link Summary) window.2.The version tab shows Code No, the Date of Manufacture, Serial No.Hardware Type, and Software Version of the ODU, IDU.Version window for (1+0)- 28 -ROI-S04451Version window for (1+1)- 29 -ROI-S044512.17 Control (CTRL) Tab2.17.1 The Control Module1.Select the CTRL tab in PNMT(Link Summary) window of the target NE.The following items can be monitored and controlled in the CTRL tab:oo o o ooCalendar AlarmDate/TimeCPU ResetDownload Configuration FileDownload Program FileUpload Configuration File2.17.2 Setting the Date/TimeThe Date and Time stored in control module can be displayed and adjusted using thisfunction.To set the Date/Time:1.Click on the [Date/Time] button in the CTRL tab.NOTETo set the value of the Date and Time field to thesame value as that of the PNMT computer, check on the Display PC Time box- 30 -ROI-S044511) To check the Date and Time on the Control module:1)-11)-21)-3Select Get Date/Time in the Date/Time window.Click on [Execute] button.The current date and time in the control will be displayed in the Dateand Time field.2). To set the Date and Time on the Control module:2)-12)-22)-3Select Set Date/Time in the Date/Time window.Click on [Execute] button.Click on [Close] button when finished.2.17.3 CPU ResetThe control module can be reset using this function. NOTEResetting the control module will not affect thetraffic. The connection to the selected Pasolink will be lost a few minutes and will be automatically re- connected.To reset the control module:1.Click on the [CPU Reset] button in CTRL tab.2.You can select the with ROM(Ctrl Program) Switching option if you want toswitch to a newly downloaded control module Program file.3.Click on [Execute] button to continue the control module reset operation.- 31 -ROI-S044512.17.4 Downloading the Configuration Files to the Control ModuleThis function is used to download configuration files from the PNMT to the controlmodule. The configuration file pp_network.cfg, contains the IP address of the CTRLas well as the IP address of the opposite station and the information about the Pasolink network where the CTRL is located. The pp_mib.cfg contains the information aboutthe equipment (i.e. name, pm type, etc.) and housekeeping (AUX I/O)To download new configuration file to the CTRL:1.Click on [Configuration File] in the button in the CTRL tabs Download(PC>>CTRL) section.2.Select the type of file to be downloaded in the Type list.3.Enter the location of the configuration file in the File field, or click on [Browse] tolocate the file on the local hard disk or diskette.WARNING!!!Make sure that the correct configuration file isdownloaded to the correct Control module. Incorrect configuration file will lead to Control module or network failure.4.Click on [Execute] button to start the operation.5.A message window indicating the status of the operation will appear. It will closeautomatically once the operation is finished.WARNING:Make sure that you have successfully downloaded theconfiguration file before doing Update. Otherwise theControl module will switch to an empty ROM that may cause Control module failure.6.Click on [Update] button to activate the new configuration file(s).- 32 -ROI-S044517.Select the appropriate box for the type of configuration file that will be updated.One or more configuration file can be updated by checking the box opposite to the configuration file name. Click on [Execute] button to start the operation. The "withROM (Ctrl Program) Switching" box is for switching to the ROM with the new CTRL Program and has the same function that was previously discussed in section 2.14.5 Downloading a new Program file to the Control Module.NOTEWhen updating pp_network.cfg file, NE-to-NEcommunication will be lost when the Control module re-initialises to the new systemconfiguration. This WILL NOT affect the radio link.During this time PNMT connection to the Pasolinkwill be lost but will automatically be reconnected after the Control module resets.8.Click on [Yes] button. When below window is opened.9.Click on [Close] button when done.- 33 -ROI-S044512.17.5 Downloading a new Program File to the Control ModuleThis function is used to update the application program on the Control module. Thisoperation affects only the NMS communication but not the radio link, and will not disrupt communication.To download the program file to control module:1.Click on [Program File] in the button in the CTRL tabs Download (PC>>CTRL)section.2.Check the CTRL button. If you tick the with Self Reset the control module willbe reset automatically after program file download is completed. In this case, you wont need to do steps 5 thru 8.3.Enter the appropriate location of the program file (*.out) in the File field. Otherwise,click [Browse] to locate the file.WARNING!!!Make sure that the correct program file isdownloaded to the Control module. Incorrect program file will lead to failure.4.Click on [Execute] button to start the operation.5.A message window will appear displaying the status of the operation. Themessage window will close automatically once the download is completed.NOTEThis operation may take several minutes dependingon the program file size.- 34 -ROI-S044516.Click on [CPU Reset] button to switch to the new program file.7. Check the with ROM(Ctrl Program) Switching box.8. Click on the [Execute] button to complete the switch to the new programfile.NOTEThe connection to the selected Pasolink+ will belost a few minutes and will automatically re-connect.2.17.6 Uploading Control Module Configuration file to PNMT PCThis function is used to upload the configuration file from the Control module of theselected Pasolink to the PNMT PC.To upload configuration file from the Control module to the PNMT:1.Click on [Configuration File] in the button in the CTRL tabs Upload(CTRL>>PC) section.2.Select the type of file to be uploaded on the Type field.3.Enter the desired file name for the uploaded file. And select and the directorywhere the uploaded file will be saved.4.Click on the [Execute] button to start the operation.- 35 -ROI-S044515.A message window indicating the status of the operation will appear. It will closeautomatically once the operation is completed.6.After the upload is finished click on [Close] button.7.Verify that the file was uploaded on the specified directory.2.18 MaintenanceThe function of each control is as follows.ControlMAINT : To switch Maintenance mode to ONMain signal Loopback-1: (Near-end Loopback) Disable for 2MB INTFC Main signal Loopback-2: (Far-end Loopback) Disable for 2MB INTFCMain signal VC12 Loopback-1/2: (Near and far -end Loopback) Available for 2MBINTFC onlyIF Loopback : (Local only)ALS Restart: To set the time of manual restart Automatic Laser Shutdown (ALS) CW(MOD Carrier): To turn on the Continuous Wave for measurements (Local only)TX Mute : To turn off TX power (Local only) TX Frequency - transmit FrequencyRX Frequency - Receive FrequencyATPC Manual - To set TX power during Automatic transmitter Power Control(ATPC)CLKLockout Control - Set CLK source which is locked outSource Select Control - Set CLK source which is used forcefullyClear WTR Timer - Clear the Waiting timer when CLK restores the normal source.- 36 -ROI-S044512.18.1 Maintenance menuTo go to maintenance window:1.Select Configuration -> Maintenance in the NE-specific menu bar.Maintenance window(1+0 configuration)Maintenance window(1+1 configuration)- 37 -Displayed at 2M INTFConlyROI-S044512.18.2 Selecting Maintenance modeTo switch the Pasolink to maintenance mode:1.Click [MAINT] button in Maintenance window.2.Select on ON/OFF depending on desired state.3.Click on [Execute] to carry out the command.4.Click on [Close] button when finished.2.18.3Switching TX (for 1+1 system only)To control the TX switch manually:1.Click [TX Switch] button in Maintenance window.2.Select the system that you want to use for the TX portion of the radio. The defaultvalue is Auto.3.Click on [Execute] button to switch the TX to the selected system.4.Click on [Close] button when finished.2.18.4 Switching RX (for 1+1 system only)To control the RX switch manually:1. Click [RX Switch] button in Maintenance window.- 38 -ROI-S044512.Select the system that you want to use for the RX portion of the radio. The defaultvalue is Auto.3.Click on [Execute] button to switch the RX to the selected system.4.Click on [Close] button when finished.2.18.5 Main Signal LoopbackFollowing loopbacks are created at the 150MB INFTC/OPT INTFC of the selected NE -where you are currently connectedMain Signal Loopback - 1 (near-end loopback)Main Signal Loopback - 2 (far-end loopback)To set the near(or far)-end loopback:1.Click on the [Main Signal Loopback] button in the Maintenance window.2.Select Loopback-1(or Loopback-2) tab on the topLoopback-1WindowLoopback-2Window3.Select ON to activate the loopback.4.Click on [Execute] button to apply the loopback.5.Click on [Close] button when finished.- 39 -ROI-S044512.18.6 IF Loopback (local only loopback)This type loopback is created at the MODEM module of the local NE.To set the local only loopback:1.Click on the [IF Loopback] button in the Maintenance window.2.Select ON to activate the loopback.3.Click on [Execute] button to apply the loopback.4.Click on [Close] button when finished.2.18.7 ALS RestartThis function is used to set the time of manual restart of the Automatic Laser Shutdown(ALS). When the optical input signal is off due to ALS, the IDU will emit laser signal from TX to RX at a preset value (2 sec or 90 sec), at this point, if the fault has been recovered then the ALS will be released and operation will return to normal. Otherwise, the laser emission will end immediately. (See Pasolink + Instruction Manual for further details.)- 40 -ROI-S04451To set the ALS restart:1.Click on [ALS Restart] button in the Maintenance window.2.Select the timing in seconds of the laser emission for manual restart.3.Click on [Execute] button to apply the timing of the manual restart.4.Click on the [Close] button when finished.2.18.8 Lockout ControlIt is possible to restrict the use of the CLK source to the INTFC set this functionTo set the Lockout Control:1.Click on [Lockout Control] button in the Maintenance window.2.Select to set the Lockout Control to Four Sources [EXT1, EXT2, MUX, DMR]respectively.3.Click on [Execute] button to apply the new setting4.Click on the [Close] button when finished.- 41 -ROI-S044512.18.9 Source Select ControlTo set the Source Select Control1.Click on [Source Select Control] button in the Maintenance window.2.Select a source type from following types as belowFreerun: operating mode of the equipment clock is free-run.Holdover: operating mode of the equipment clock is hold-over. Auto: operating mode of equipment clock is normal.3.Click on [Execute] button to apply the new setting4.Click on the [Close] button when finished.2.18.10 Clear WTR TimerIt is possible to clear the waiting timer from setting the new CLK to reset the currentCLK.To check the Clear WTR Timer:1.Click on [Clear WTR Timer] button in the Maintenance window.2.Select Clear the action of waiting timer to restartwhen you will switch over the CLK- 42 -ROI-S044513.Click on [Execute] button to apply the new settingClick on the [Close] button when finished.4.2.18.11 Selecting TX Mute statusTX power of the ODU is switched off when TX Mute is ON. This should be OFF innormal operation.To change the TX Mute status:1.Click [TX Mute] button in Maintenance windowNOTESwitch ON maintenance mode first before performing TX Mute.2.Select ON/OFF depending on the desired state.3.Click on [Execute] button to carry out the command.4.Click on [Close] button when finished.2.18.12 TX FrequencySets the RF transmitted frequency and consequently its pair receiving frequency.(Proceed to 2.16 Equipment Setup.)NOTESwitch ON maintenance mode first before performingTX Frequency.2.18.13 RX FrequencyDisplays the current RF receiving frequency used by the ODU.(Proceed to 2.16 Equipment Setup.)NOTESwitch ON maintenance mode first before performingRX Frequency.- 43 -ROI-S044512.18.14 Selecting Carrier Wave statusWhen doing frequency measurements, the CW should be turned OFF to have anunmodulated signal. During normal operations this status should be ON.To change the CW (MOD Carrier) status:1. Click [CW (MOD Carrier)] button in Maintenance windowNOTESwitch ON maintenance mode first before performing CW.2.Click on ON/OFF button depending on desired state.3.Click on [Execute] button to carry out command.4.Click on [Close] button when finished.2.18.15 ATPC ManualUsed when an optional transmitting power is required when the ATPC is in operation.To set the ATPC Manual:1.Click [ATPC Manual] button in Maintenance windowNOTESwitch ON maintenance mode first before performing ATPC Manual.2.Select the whether to manually turn ON or OFF the ATPC manual and theATPC manual power that will be transmitted in dB.3.Click on [Execute] button to activate the new setting.4.Click on [Close] button when finished.- 44 -ROI-S044512.19 Equipment SetupMain signal, ODU and CTRL portion can be monitored and controlled in this window.2.19.1 Equipment Configuration WindowTo open the Equipment Configuration Monitor:1.Select Configuration -> Equipment Setup in the NE-specific menu bar.2.This window contains the setup information and control for the IDU and the ODU.The Equipment Setup window is shown below.- 45 -ROI-S044512.19.2 SetupTo setup the ODU and IDU parameters:1.Click on the [Setup] button in the Equipment Setup window.2.On the Setup window, the configurable items are shown and described in thetable below:3.Click on [Execute] button to apply the new set of values- 46 -ODUStart Frequency - Minimum of Available Frequency BandStop Frequency - Maximum of available Frequency BandShift Frequency - TX/RX frequency spacingUpper/Lower - Positional relation of TX frequencyTX Frequency - sets the RF transmit frequency and consequently the RFreceive frequency of the ODUTX Power Control - method used by the ODU for power control functions can be set here. Either Automatic Transmit Power Control (ATPC) or Manual Transmit Power Control (MTPC) can be selected.IDURedundancy - This function Is available only for 1+1 systems Hot-Stand-By orTwin-Patch configuration can be set using this function.System - The name of equipmentSOH Termination - Section Overhead TerminationMain INTFC - the main interface of IDU can be selected here. The available interfaces are STM-1(Optical), STM-1(Electrical) or 21CH X 2MBModulation - Modulation formFrame ID - used to synchronize the TX and RX frames of opposing NEs in the hop. The frame ID can be set from 1 to 8.CTRLNE Name - Name of NEIP Address - IP Address of NENote - Used to describe the short messageROI-S04451CAUTION:Changing the TX/RX CH will interrupt the traffic.2.19.3 Editing the NE NameTo edit the NE name:1.Click [NE Name] button in Equipment Setup window.2.Enter new Pasolink name in the NE Name dialog box. A maximum of 32characters can be used.3.Click on [Execute] button to change to new name.4.Click on [Close] button when finished.2.19.4 Editing the Note for CTRLTo put an optional description on the current Pasolink:1.Click [Note] button in Equipment Setup window.2.Enter the optional description for the specific Pasolink in the Note dialog box. Amaximum of 100 characters can be used in this field3.Click on [Execute] button when finished.4.Click on [Close] button when finished.- 47 -ROI-S044512.20 ProvisioningThe main interface (MAIN INTFC), overhead (OH), ThresholdSUB INTFC, MTPC and ATPC can be set in this window.2.20.1 Provisioning WindowTo open the Equipment Configuration Monitor:1.Select Configuration -> Provisioning in the NE-specific menu bar.2.This window contains the setup information of the Main INTFC, OH, Threshold,SUB INTFC, MTPC and ATPC. The Provisioning window is shown below.- 48 -ROI-S04451Provisioning Window (1+1)2.20.2 MAIN INTFC2.20.2.1Enabling the ALSWhen the ALS is enabled, the laser emission will be cut off after a certain period haveelapsed after the IDU have issued an STM-1 LOS. If the ALS is disabled, the laser emission will be continuously outputted.To enable the ALS:1. Click on the [ALS] button on the Provisioning window.2. Select Enable on the ensuing window.- 49 -ROI-S044513. Click on [Execute] button to enable the ALS.4. Click on [Close] button when finished.2.20.2.2Setting the ALS Delay Time (ALS Restart)This function allows you to set the time in seconds before the ALS will try automaticallyto release the laser lock-off. After the preset time have elapsed, the IDU will emit laser intermittently and if the fault have been corrected the ALS will be released and continue with the normal operation. Otherwise, the laser will be immediately cut off.To set the ALS delay time:1.Click on the [ALS Delay Time] button on the Provisioning window.2.Select the time in seconds when the ALS will try to automatically release the lock-off in laser emission in the ensuing window.3.Click on [Execute] button to apply the new setting.4.Click on [Close] button when finished.2.20.2.3AIS Activation ConditionWhen E-BER Alarm occurs, this function enable Alarm Indication Signal (or AIS) to beActive- 50 -ROI-S044512.20.2.4MS RDI Activation ConditionWhen E-BER Alarm occurs, this function enable MS RDI to be Active.2.20.2.5AIS Send(Loopback-1)This function is used to set whether AIS is sent to the opposite station when Near-endloopback is performed2.20.2.6AIS Send(Loopback-2)This sets whether AIS is sent to the MUX when Far-end loopback is performed.2.20.2.7VC12 AssignmentThis function is used to assign the virtual container number to the physical channelnumber.It is possible to assign the VC number to the same physical channel number by selecting [Easy]It is possible to assign the VC number to the desired physical channel number byselecting [Customize]- 51 -ROI-S04451NOTE:It is essential for Execute to assign all Channels orVC12s.2.20.2.8Channel Usage ErrorThis function is used to report the alarms from the main channel.- 52 -ROI-S044512.20.2.9CLK ProvisioningProvision of clock can be set in this WindowExternal CLK Interface: Kind of external clock interface selected from thefollowing items.Not Used:2MHz:2MB:When the External clock is not provided.When the External clock is 2.048MHzWhen the External clock is 2.048Mbps.Selected External Output: When an External clock is selected, this defines thesource of the CLK signal that is set out to the EXT CLK OUT ports, to be used by external equipment. Select:Equipment: The EXT CLK output is derived from the PLL.Line:The EXT CLK output is derived from a CLK extracted from an STMsignal (MUX/DMR CLK)QL (Quality) Mode: To monitor the SSM. In this mode, the clock source havingthe highest quality and priority will be selectedEXT OUT Priority Level [for line]: This setting is used by the equipment to decidewhich of the line clock signals will be supplied by the EXT OUT port.NOTEIn this priority setting , 1 is the highest priorityand 4 is the lowest priority. A CLK source having a priority set to disable will not be considered for CLK selectionEquipment Priority Level [Port Usage]: This sets the priority levelSSM Supported [Input Port] [STM Input EXT IN/OUT]: This setting defines tosupports the SSM or notQL Overwrite: This setting defines whether the quality (QL) value is overwrittenwith a fixed value.QL Fixed Value: This sets the fixed quality value of each CLK source.SSM Usage for STM Output: This sets whether SSM value sent for STM output.Usually, Enabled is set. At the border of the network, Disabled is set when theSSM value should not be sent to the other network.Wait to Restore [WTR] Timer: When a selected clock source is cut off, anotheravailable clock source is automatically selected. If the cut off clock that is restored, a waiting period is required before the equipment judges that the CLKis indeed restored and may now be re-selected. The wait to restore timedefines the waiting period.Line Extracted CLK Squelched by MS-AIS: Select yes to squelch the line clockif MS-AIS is detected in the STM signal where the line clock is extracted.QL Minimum Value: QL Minimum Value sets minimum quality of the EXT CLKOUT signal.- 53 -ROI-S04451External SSM Channel [Sax]: this defines which Sax bit is used to convey theSSM when the EXT CLK is set to 2MB. This setting is common for both EXT CLK IN and EXT CLK OUT ports.External CLK Output Control:Continue: To prevent the EXT OUT CLK signal when the internal (free-run, holdover) clock gets selected as the EXT OUT signal. This item is usually set toAuto2.20.2.10 Section Trace J0 DetectThis function sets the Section Trace J0 detectable.- 54 -ROI-S044512.20.2.11 Section Trace J1 DetectThis function sets Section Trace J1 detectable.2.20.3 Overhead (OH) Assignment2.20.3.1OH Assignment TypeThe OH can be either set at factory default (Easy) or customized (Custom) accordingto user requirements.To set the OH Assignment type:1.Click on the [Assignment] button in the Provisioning window.2.Select the type of OH assignment that will be employed.3.Click on [Execute] button to apply the setting.4.Click on [Close] button when finished.2.20.3.2DirectionTo set the direction:1.Click on the [Direction] button in the OH Assignment table.2.On the ensuing table, you will be able to select the direction for the V11-1 andV11-2 interface.- 55 -ROI-S044513.Click on [Execute] button to apply the new setting.4.Click on [Close] button when finished.2.20.3.3Channel UsageThis function allows you to set the interface used on the available user channels (E1,F1, DSC, etc.) in the Pasolink +. The user channels can be set as V11, VF or LAN (Ethernet) using this function.To set the channel usage:1.Click on the [Channel Usage] button in the OH Assignment table.2.On the ensuing window, the channel usage table will be displayed. You canassign a target channel to use a specific interface by plotting the channel(column) and the interface (row) on the table and clicking on the button that corresponds to the target channel and interface. Note that for each channel youcan set only one interface.3.Click on [OK] button to apply the new settings.2.20.4 Manual Transmit Power Control (MTPC) StatusWhen the MTPC is selected over ATPC the buttons on this section will becomesensitive and the MTPC parameters can be set. The MTPC has three (3) parameters: MTPC TX Power RX Threshold Additional AttenuationThe procedure for setting these parameters will be presented in this section.- 56 -ROI-S044512.20.4.1MTPC TX PowerWhen the MTPC is in operation, the transmission power (dB) can be set using thisfunction.To set the maximum transmission power in MTPC:1.Click on [MTPC TX Power] button in the Provisioning button.2.Set the power (dB) in the ensuing window. You can either highlight the input fieldand enter the dB value using the keypad or use the arrows on the right-hand corner of the field to increase or decrease the value shown in the input field.3.Click on [Execute] button to apply the maximum MTPC TX power.4.Click on [Close] button when finished.2.20.4.2RX ThresholdSets the threshold value of the receiving level. When the received level converge onthe preset value of the threshold the TX power is controlled by sending control signals in the Radio Frame Complementary Overhead (RFCOH).To set the RX threshold:1.Click on the [RX Threshold] button in the MTPC status section of theProvisioning window.2.Set the power (dB) in the ensuing window. You can either highlight the input fieldand enter the dB value using the keypad or use the arrows on the right-hand corner of the field to increase or decrease the value shown in the input field.3.Click on [Execute] button to apply the new preset value.4.Click on [Close] button when finished.- 57 -ROI-S044512.20.4.3Additional AttenuationIf the transmission length of the radio section is short, additional span attenuators canbe set in the ODU. The additional attenuation can be set from 0 to 5 dB.To set the additional attenuation:1.Click on the [Additional Attenuation] button in the MTPC status section of theProvisioning window.2.Set the attenuation (dB) in the ensuing window. You can either highlight the inputfield and enter the dB value using the keypad or use the arrows on the right-hand corner of the field to increase or decrease the value shown in the input field3.Click on [Execute] button to apply the attenuation.4.Click on [Close] button when finished.2.20.5 Automatic Transmit Power Control (ATPC) StatusWhen the ATPC is selected over MTPC the buttons on this section will becomesensitive and the ATPC parameters can be set. The ATPC has five (5) parameters:TX MAX PowerTX MIN Power RX Threshold Additional AttenuationODU ALM ModeThe procedure for setting these parameters will be presented in this section.2.20.5.1TX MAX PowerWhen the ATPC is in operation, the maximum transmission power (dB) can be setusing this function.To set the maximum transmission power in ATPC:1. Click on [TX MAX Power] button in the Provisioning button.2. Set the power (dB) in the ensuing window. You can either highlight the input fieldand enter the dB value using the keypad or use the arrows on the right-hand corner of the field to increase or decrease the value shown in the input field.- 58 -ROI-S044513. Click on [Execute] button to apply the maximum ATPC TX power.4. Click on [close] button when finished.2.20.5.2TX MIN PowerWhen the ATPC is in operation, the minimum transmission power (dB) can be setusing this function.To set the minimum transmission power in ATPC:1.Click on [TX MIN Power] button in the Provisioning button.2.Set the power (dB) in the ensuing window. You can either highlight the input fieldand enter the dB value using the keypad or use the arrows on the right-hand corner of the field to increase or decrease the value shown in the input field.3.Click on [Execute] button to apply the minimum ATPC TX power.4.Click on [Close] button when finished.2.20.5.3RX ThresholdSets the threshold value of the receiving level. When the received level converge onthe preset value of the threshold the TX power is controlled by sending control signals in the Radio Frame Complementary Overhead (RFCOH).To set the RX threshold:1. Click on the [RX Threshold] button in the ATPC status section of the Provisioningwindow.2. Set the power (dB) in the ensuing window. You can either highlight the input fieldand enter the dB value using the keypad or use the arrows on the right-hand corner of the field to increase or decrease the value shown in the input field.- 59 -ROI-S044513. Click on [Execute] button to apply the new preset value.4. Click on [Close] button when finished.2.20.5.4Additional AttenuationIf the transmission length of the radio section is short, additional span attenuators canbe set in the ODU. The additional attenuation can be set from 0 to 5 dB.To set the additional attenuation:1.Click on the [Additional Attenuation] button in the ATPC status sectionof the Provisioning window.2.Set the attenuation (dB) in the ensuing window. You can either highlightthe input field and enter the dB value using the keypad or use the arrows on the right-hand corner of the field to increase or decrease the value shown in the input field3.Click on [Execute] button to apply the attenuation.4.Click on [Close] button when finished.2.20.5.5ODU ALM ModeIn cases wherein the ODU losses communication with the IDU due to failure of somesort, the response of the ODU can be preset using this function. Since the control function of the TX power is in the IDU, the ODU will be cut-off to this control when afailure in the communication between the ODU and the IDU occurs. In this case, the ODU either mutes the TX or Hold the current TX power, depending on the preset ODU ALM mode.To set the ODU ALM mode:1. Click on the [ODU ALM Mode] button in the ATCP status section of theProvisioning window.2. Select the action of the ODU in case of IDU communication failure. For ATPC,MAX, MIN or Hold mode is available.- 60 -ROI-S044513. Click on [Execute] button to apply the new setting.4. Click on [Close] button when finished.2.20.6 SW priority2.20.6.1 TX SW PriorityThe TX SW priority defines the channel that will be selected by the TX switch when both channels are normal.Non-priority : There is no priority.Priority No.1: Priority is given to No.1 channel.To set the TX switch priority :1.Click on the [TX SW Priority] button in the SW Priority of the Provisioningwindow.2.Select the type of TX switch priority.3.Click on [Execute] button to apply the new setting.4.Click on [Close] button when finished.2.20.6.2 RX SW PriorityThe RX SW priority defines the channel that will be selected by the RX switch when both channels are normal.Non-priority: There is no priority.Priority No.1: Priority is given to No.1 channelTo set the RX switch priority :1.Click on the [RX SW Priority] button in the SW Priority of the Provisioningwindow.2.Select the type of RX switch priority.- 61 -ROI-S044513.Click on [Execute] button to apply the new setting.Click on [Close] button when finished.4.2.20.7 Sub INTFCThere are 4 optional sub interfaces available in the Pasolink + system. On this section,these sub-interfaces can be defined and specified accordingly.2.20.7.1Defining the SUB INTFCTo set the type of sub interface mounted in the IDU:1.Click on the [SUB INTFC] button in the Provisioning window.2.Select the type of interface used from the ensuing window. If there is no oneof 4 sub interfaces, Not used must be selected.3.Click on [Execute] button to apply the newly defined sub interface.4.Click on [Close] button when finished.2.20.7.2Defining the Wayside (WS) InterfaceTo specify the type of WS interface used:1.Click on the [WS INTFC] button in the Provisioning window.2.Select the type of WS interface on the ensuing window.- 62 -ROI-S044513.Click on [Execute] button to apply the new setting.4.Click on [Close] button when finished.2.20.7.3WS Line LengthTo specify the WS line length:1.Click on the [WS Line Length] button in the Provisioning window.2.Select the line length in meters from the ensuing window. The WS line length canbe set from 0 to 199 meters (from 0 to 655 ft).3.Click on [Execute] button to apply the newly specified length.4.Click on [Close] button when finished.2.20.8BER Threshold- 63 -From MUX From DMR MUX RADIO(1) (3) (2) Signal Degrade (B1,B2) E-BER (B1, B2, B3) Signal Degrade (B1,B2)Low BER E-BER (B1, B2, B3) (RX Switch) High BERROI-S04451The BER in the Pasolink+ system is monitored in 3 sections - (1) the MUX section,(2) the DMR section and the (3) Radio section. The Radio section is available 1+1systems only and is used for switchover function. The figure below illustrates these sectionsThe MUX and DMR section BER is measured in terms of Signal Degrade and E-BER.Signal Degrade is triggered when the BER is worse than the preset threshold (1E-6,1E-7, etc.). Excessive BER (E-BER) occurs when the BER is worse than the preset threshold (1E-3, 1E-4, or 1E-5).The radio section, on the other hand, monitors the BER for switchover purposes. Whenthe BER becomes worst than the preset value (3E-6,3E-7, etc) of the Low BER (RX Switch) the RX is switched to the other system in a 1+1 configuration. In a similarmanner, when the BER becomes worse than the preset value (3E-4,3E-5,3E-6) forHigh BER, the switched to the other system.The preset value mentioned above is called the BER Threshold. The BER thresholdcan be set in 6 points: (1) Signal Degrade (MUX), (2) E-BER (MUX), (3) Signal Degrade (DMR), (4) E-BER (MUX), (5) Low BER, and (6) High BER. Low BER and High BER, however, are only available in 1+1 systems.The MUX and DMR are classified with B1, B2 and B3 section respectively. There is E- BER only for B32.20.8.1B1 Signal Degrade (MUX)To set the threshold for signal degrade:1.Click on the [B1 Signal Degrade (MUX)] button in the Provisioning window.2.Select the preset BER value that will trigger the signal degrade. The factorysetting is 1E-6.3.Click on [Execute] button to apply the new threshold.4.Click on [Close] button when finished.2.20.8.2B1 E-BER (MUX)To set the E-BER Threshold for the MUX section:1. Click on the [B1 E-BER (MUX)] button in the Provisioning window.2. Select the preset value wherein the E-BER will be triggered.- 64 -ROI-S044513. Click on [Execute] button to apply the new threshold.4. Click on the [Close] button when finished.2.20.8.3B2 Signal Degrade (MUX)To set the threshold for signal degrade:1.Click on the [B2 Signal Degrade (MUX)] button in the Provisioning window.2.Select the preset BER value that will trigger the signal degrade. The factorysetting is 1E-6.3.Click on [Execute] button to apply the new threshold.4.Click on [Close] button when finished.2.20.8.4B2 E-BER (MUX)To set the E-BER Threshold for the MUX section:1. Click on the [B2 E-BER (MUX)] button in the Provisioning window.2. Select the preset value wherein the E-BER will be triggered.3. Click on [Execute] button to apply the new threshold.4. Click on the [Close] button when finished.- 65 -ROI-S044512.20.8.5B3 E-BER (MUX)To set the E-BER Threshold for the MUX section:1. Click on the [B3 E-BER (MUX)] button in the Provisioning window.2. Select the preset value wherein the E-BER will be triggered.3. Click on [Execute] button to apply the new threshold.4. Click on the [Close] button when finished.2.20.8.6B1 Signal Degrade (DMR)To set the threshold for signal degrade:1.Click on the [B1 Signal Degrade (DMR)] button in the Provisioning window.2.Select the preset BER value that will trigger the signal degrade. The factory settingis 1E-6.3.Click on [Execute] button to apply the new threshold.4.Click on [Close] button when finished.- 66 -ROI-S044512.20.8.7B1 E-BER (DMR)To set the E-BER Threshold for the DMR section:1.Click on the [E-BER (DMR)] button in the Provisioning window.2.Select the preset value wherein the E-BER will be triggered.3.Click on [Execute] button to apply the new threshold.4.Click on the [Close] button when finished.2.20.8.8B2 Signal DegradeTo set the threshold for signal degrade:1.Click on the [B2 Signal Degrade (DMR)] button in the Provisioning window.2.Select the preset BER value that will trigger the signal degrade. The factory settingis 1E-6.3.Click on [Execute] button to apply the new threshold.4.Click on [Close] button when finished.- 67 -ROI-S044512.20.8.9B2 E-BERTo set the E-BER Threshold for the DMR section:1.Click on the [B2 E-BER (DMR)] button in the Provisioning window.2.Select the preset value wherein the E-BER will be triggered.3.Click on [Execute] button to apply the new threshold.4.Click on the [Close] button when finished.2.20.8.10 B3 E-BERTo set the E-BER Threshold for the DMR section:1.Click on the [B3 E-BER (DMR)] button in the Provisioning window.2.Select the preset value wherein the E-BER will be triggered.3.Click on [Execute] button to apply the new threshold.4.Click on the [Close] button when finished.- 68 -ROI-S044512.20.8.11 High BER (Radio) [for 1+1 systems only]To set the threshold for High BER:1.Click on the [High BER] button in the Provisioning window.2.Select the preset BER value that will trigger the signal degrade. The factorysetting is 3E-4.3.Click on [Execute] button to apply the new threshold.4.Click on [Close] button when finished.2.20.8.12 RX Switch (Radio) [for 1+1 systems only]To set the Low BER:1.Click on the [RX Switch] button in the Provisioning window.2.Select the preset value wherein the E-BER will be triggered.3.Click on [Execute] button to apply the new threshold.4.Click on the [Close] button when finished.- 69 -ROI-S044512.21 Link Performance MonitorThe following performance items can be monitored according to G.826 recommendation:Out of Frame Second (OFS) - the total number of seconds the out of frame conditionis generated in 15 minute-blocks. Errored Second (ES) the cumulative time in which more than one B1 errorpulse per second was detected (ES is not applied to the MSA) Severely Errored Second (SES) the cumulative time in which the BER of one-second period exceeded 10E-3. (SES is not applied to the MSA) Unavailable Second (UAS) the cumulative time in which the unit remainedinoperative (UAS is not applied to the MSA) Background Block Error (BBE) - the sum of the B1 background block error PJE+ (is applied to the MSA only) PJE (is applied to the MSA only)Red color in Performance monitor window indicates the occurrence of performance itemsexceeding the threshold value. The threshold values can be set in Threshold window. The detailed daily performance data can be seen by clicking on the [Detail] button.2.21.1 Viewing Summary Link Performance MonitorTo view Summary Link Performance Monitor:1.Click on Link Performance Monitor in the NE-specific menu bar of the targetPasolink the Pasolink that you intend to monitor. And select the item on the ensuing window.AS for [Section Trace] and [signal Label], proceed to chart 2.18.5Summary Link Performance Monitor Window (ex; RST)- 70 -(OFS is applied to the RST only)ROI-S044512.21.2 Threshold settingTo set the threshold values:1.Click on [Threshold] button in the Summary Link Performance Monitor window- 71 -This check box is used to set the same value to allVC12s , and this is equipped with the LPT layer windowThreshold setting Window (ex; RST)Summary Link Performance Monitor Window (ex; LPT)ROI-S044512.Select the performance item that is to be configured on the table shown above.The G.826 measure becomes available for setting when selected. The arrow buttons on the left-hand side of the field indicates this.3.Set the value when the alarm Occur and when the alarm Recover in theappropriate field. The measure will issue an alarm status when it reaches the alarm occur value or issue an alarm clear status when it reaches the recovervalue set in the threshold table.4.Click on [Execute] button to activate the new settings.5.Click on [Close] button when finished.2.21.3 Link Performance Monitor (Daily Data) window.This window contains the Link Performance data of the current 8 days.To view the Link Performance Monitor (Daily Data) window:1.Click [Detail] button in Link Performance Monitor window.Link Performance Monitor window (ex: RST)2.On this window a table presents the available data in the CTRL. The table ispresented as G.826 measure versus the Date. The date buttons on the right-hand side of the table is selectable. Moreover, the buttons reflect the summary alarmfor that specific date.3.Click on the date buttons to display the detailed 15-min data for that date.- 72 -ROI-S044512.21.4 Link Performance Monitor (15 min Data) windowTo view the 15-min Data:1.Click button of the target date in Link Performance Monitor (Daily Date) window todisplay the detailed 15-min performance data.SaveLink Performance Monitor (15-min Data) window (ex; RST)Refresh2.The data can be saved in text format by clicking on the save icon. Or can berefreshed by clicking on the refresh button.2.21.5 Section TraceThis function is used to enter Section Trace of J0 J1 and J2 byte.The following items are displayedTransmitting Pattern: Pattern to transmitted to MUX or DMRExpected Pattern: Expected Pattern to received from MUX or DMRReceived Pattern: Actual Pattern to received from MUX or DMR- 73 -ROI-S04451To view the threshold values:1.Click on Link Performance Monitor in the NE-specific menu bar of the targetPasolink the Pasolink that you intend to monitor. And select [Section Trace] window.- 74 -Check Box: This function is used to appoint someVC12s to be detected J2 byteThis function is used to remove all check of VC12This function is used to check all VC12ROI-S044512.21.6 Section Trace J0 (MUX)To set the threshold values:1. Click on [MUX] button in the [Section Trace J0] window2. Enter the transmitting and expected patternsCAUTION:Characters corresponds to the ASCII code 20h to 7Fh are validfor transmitting/expected pattern. Fifteen characters must be entered. If less than fifteen characters are entered, rest that characters has been not entered are recognized as space (ASCII code 20h).2.21.7 Section Trace J0 (DMR)To set the threshold values:1.Click on [DMR] button in the [Section Trace J0] window2.Enter the transmitting and expected patternsCAUTION:Characters corresponds to the ASCII code 20h to 7Fh are validfor transmitting/expected pattern. Fifteen characters must be entered. If less than fifteen characters are entered, rest that characters has been not entered are recognized as space (ASCIIcode 20h).- 75 -ROI-S044512.21.8 Section Trace J1 (MUX)To set the threshold values:1. Click on [MUX] button in the [Section Trace J1] window2. Enter the transmitting and expected patternsCAUTION:Characters corresponds to the ASCII code 20h to 7Fh are valid fortransmitting/expected pattern. Fifteen characters must be entered. Ifless than fifteen characters are entered, rest that characters has been not entered are recognized as space (ASCII code 20h).2.21.9 Section Trace J1(DMR)To set the threshold values:1.Click on [DMR] button in the [Section Trace J1] window2.Enter the transmitting and expected patternsCAUTION:Characters corresponds to the ASCII code 20h to 7Fh are validfor transmitting/expected pattern. Fifteen characters must be entered. If less than fifteen characters are entered, rest thatcharacters has been not entered are recognized as space (ASCIIcode 20h).- 76 -ROI-S044512.21.10 Section Trace J2To set the threshold values:1.Click on the number of [VC12] button in the [Section Trace J2] window2.Enter the transmitting and expected patternsCAUTION:Characters corresponds to the ASCII code 20h to 7Fh are validfor transmitting/expected pattern. Fifteen characters must be entered. If less than fifteen characters are entered, rest thatcharacters has been not entered are recognized as space (ASCIIcode 20h).2.21.11 Signal LabelThis function is used to monitor Signal LabelTo monitor the Signal Label values:1.Click on Link Performance Monitor in the NE-specific menu bar of the targetPasolink the Pasolink that you intend to monitor. And select [Signal Label] window.2.As for Signal Label(LPT), Click on VC12 button, and check the desired VC123.Execute Refresh- 77 -ROI-S04451- 78 -Refresh: Get the current Signal Label valueROI-S044512.22 Event logThe Event Log Windows displays the date when the event or command was received, the equipment, item, and status.2.21.1 Event log monitor1.Click on Event Log in the NE-specific menu bar of the target Pasolink thePasolink that you intend to monitor.2.A message window showing the progress of the uploading of the Event Log datawill appear on the screen. Wait until the PNMT finishes the uploading of the data. The progress window will automatically close once the uploading is completed.3.The Event Log View will be displayed. The event log is presented in a table formshowing the date of the event, the item that triggered the event and the status change.4.Sorting is possible for every column in EventLog window.5.The date shown in the Event Log window will be the format set up by OS- 79 -