Pneumatic Products...LT113HD1LPA Mechanical 1/4" 0 F to 120 F .83 Cv Part Number Voltage Port Size...

10
Parker Hannifin Corporation Pneumatic Division Richland, Michigan www.parker.com/pneumatics 85 Pneumatic Products LOAD-TAMER™

Transcript of Pneumatic Products...LT113HD1LPA Mechanical 1/4" 0 F to 120 F .83 Cv Part Number Voltage Port Size...

Page 1: Pneumatic Products...LT113HD1LPA Mechanical 1/4" 0 F to 120 F .83 Cv Part Number Voltage Port Size Temperature Flow LT113RA1RPA 12VDC 1/8" 0 F to 120 F .75 Cv LT113SA1RPA 24VDC 1/8"

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatics

85

Pneumatic Products

LOAD-TAMER™

Page 2: Pneumatic Products...LT113HD1LPA Mechanical 1/4" 0 F to 120 F .83 Cv Part Number Voltage Port Size Temperature Flow LT113RA1RPA 12VDC 1/8" 0 F to 120 F .75 Cv LT113SA1RPA 24VDC 1/8"

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatics

86

Outlet #4

Outlet #2

SupplyExh

ExhOutlet #4

Outlet #2

Supply

ToggleDown

ToggleUp

Outlet #4

Outlet #2

SupplyExh

ExhOutlet #4

Outlet #2

Supply

Electrical Switch Up

Electrical Switch Down

LOAD-TAMER™ Air Control ModuleElectrical Switch, Toggle Valve

Catalog 0650-E

Functional Diagrams

Electrical Switch and Low Temperature Electrical Switch (Raise)

Electrical Switch and Low Temperature Electrical Switch (Lower)

Electrical Switch Up

Electrical Switch Down

Outlet #4

Outlet #2

SupplyExh

ExhOutlet #4

Outlet #2

Supply

OperationThe operator controls the outlet pressure by using the regulator and the electrical switch valve. System pressure, indicated in the illuminated gauge, is set by the pressure regulator. Pressure is increased by turning the knob in aclockwisedirection;turningtheknobintheoppositedirection reduces it. When the switch is moved to the UP position, pressurized air is supplied to the regulator. Both the electrical switch valve and the regulator have exhaust ports, so that moving the switch to the DOWN position causes the system air to be exhausted through both devices.

Toggle Valve (Lower) Toggle

Down

ToggleUp

Outlet #4

Outlet #2

SupplyExh

ExhOutlet #4

Outlet #2

Supply

OperationThe operator controls the outlet pressure by using the regulator and the toggle valve. System pressure, indicated in the illuminated gauge, is set by the pressure regulator. Pressure is increased by turning the knob in a clockwise direction;turningtheknobintheoppositedirectionreducesit. When the toggle is moved to the UP position, pressurized air is supplied to the regulator. Both the toggle valve and the regulator have exhaust ports, so that moving the toggle to the DOWN position causes the system air to be exhausted through both devices.

OperationThe operator controls the outlet pressure by using the regulator and the toggle valve. System pressure, indicated in the illuminated gauge, is set by the pressure regulator. Pressure is increased by turning the knob in a clockwise direction;turningtheknobintheoppositedirectionreducesit. When the toggle is moved to the DOWN position, pressurized air is supplied to the regulator. Both the toggle valve and the regulator have exhaust ports, so that moving the toggle to the UP position causes the system air to be exhausted through both devices.

Toggle Valve (Raise)

OperationThe operator controls the outlet pressure by using the regulator and the electrical switch valve. System pressure, indicated in the illuminated gauge, is set by the pressure regulator. Pressure is increased by turning the knob in aclockwisedirection;turningtheknobintheoppositedirection reduces it. When the switch is moved to the DOWN position, pressurized air is supplied to the regulator. Both the electrical switch valve and the regulator have exhaust ports, so that moving the switch to the UP position causes the system air to be exhausted through both devices.

Page 3: Pneumatic Products...LT113HD1LPA Mechanical 1/4" 0 F to 120 F .83 Cv Part Number Voltage Port Size Temperature Flow LT113RA1RPA 12VDC 1/8" 0 F to 120 F .75 Cv LT113SA1RPA 24VDC 1/8"

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatics

87

Pressurized

Outlet #4

Outlet #2

SupplyExh

Exh

No Pressure

Outlet #4

Outlet #2

Supply

Catalog 0650-E

Functional Diagrams

Push-Pull Valve (Lower)

OperationThe operator controls the outlet pressure by using the regulator and the push-pull valve. System pressure, indicated in the illuminated gauge, is set by the pressure regulator. Pressure is increased by turning the knob in a clockwisedirection;turningtheknobintheoppositedirectionreduces it. When the push-pull is pulled out to the ON position, pressurized air is supplied to the regulator. Both the push-pull valve and the regulator have exhaust ports, so that pushing the push-pull in to the OFF position causes the system air to be exhausted through both devices.

OperationThe operator controls the outlet pressure by using the regulator and the push-pull valve. System pressure, indicated in the illuminated gauge, is set by the pressure regulator. Pressure is increased by turning the knob in a clockwisedirection;turningtheknobintheoppositedirectionreduces it. When the push-pull is pushed in to the ON position, pressurized air is supplied to the regulator. Both the push-pull valve and the regulator have exhaust ports, so that pulling the push-pull out to the OFF position causes the system air to be exhausted through both devices.

Push-Pull Valve (Raise)

OperationThe operator controls the outlet pressure by using the regulator and the remote pilot valve. System pressure, indicated in the illuminated gauge, is set by the pressure regulator. Pressure is increased by turning the knob in a clockwisedirection;turningtheknobintheoppositedirectionreduces it.

Remote Pilot Valve (Raise) Pressurized

Outlet #4

Outlet #2

SupplyExh

Exh

No Pressure

Outlet #4

Outlet #2

Supply

Lift Outlet

Ride Outlet

Lift Outlet

Ride Outlet

SupplyExh

ExhSupply

OFF (OUT)

ON (IN)

Lift Outlet

Ride Outlet

Lift Outlet

Ride Outlet

SupplyExh

ExhSupply

OFF (IN)

ON (OUT)

OperationThe operator controls the outlet pressure by using the regulator and the remote pilot valve. System pressure, indicated in the illuminated gauge, is set by the pressure regulator. Pressure is increased by turning the knob in a clockwisedirection;turningtheknobintheoppositedirectionreduces it.

Remote Pilot Valve (Lower)

LOAD-TAMER™ Air Control ModulePush-Pull Valve, Remote Pilot Valve

Page 4: Pneumatic Products...LT113HD1LPA Mechanical 1/4" 0 F to 120 F .83 Cv Part Number Voltage Port Size Temperature Flow LT113RA1RPA 12VDC 1/8" 0 F to 120 F .75 Cv LT113SA1RPA 24VDC 1/8"

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatics

88

LOAD-TAMER™ Air Control ModuleCatalog 0650-E

Notes

Page 5: Pneumatic Products...LT113HD1LPA Mechanical 1/4" 0 F to 120 F .83 Cv Part Number Voltage Port Size Temperature Flow LT113RA1RPA 12VDC 1/8" 0 F to 120 F .75 Cv LT113SA1RPA 24VDC 1/8"

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatics

89

Port Sizes (Excluding Preplumbed Ports)

• Inlet: 1/8"and1/4"NPTF •Outlet:1/8"and1/4"NPTF

Operating Pressure

• 0to160PSIG

Operating Temperature • StandardTemperature 0°F to 120°F (-18°C to 49°C)

• LowTemperature -20°F to 120°F (-28°C to 49°C)

Flow Rating

• 0.2Cvto1.4Cv

Gauge Scale

• 160PSI

Air Control ModuleLOAD-TAMER™

Catalog 0650-E

General Specifications

General Specifications

Plastic Housing Mount

L Bracket Mount

Flat Plate Mount

Page 6: Pneumatic Products...LT113HD1LPA Mechanical 1/4" 0 F to 120 F .83 Cv Part Number Voltage Port Size Temperature Flow LT113RA1RPA 12VDC 1/8" 0 F to 120 F .75 Cv LT113SA1RPA 24VDC 1/8"

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatics

90

Catalog 0650-E

Common Part Numbers

Plastic Housing Mount

Part Number Voltage Port Size Temperature Flow

LT111PA1LPA Mechanical 1/8" 0°Fto120°F .2Cv

Part Number Voltage Port Size Temperature Flow

LT111RA1RPA 12VDC 1/8" 0°Fto120°F .75Cv

LT111SA1RPA 24VDC 1/8" 0°Fto120°F .75Cv

LT111MA1RPA 12VDC 1/8" -20°Fto120°F .75Cv

LT111NA1RPA 24VDC 1/8" -20°Fto120°F .75Cv

Part Number Voltage Port Size Temperature Flow

LT111VA1LPA RemotePilot 1/8" -20°Fto120°F .75Cv

Push / Pull Control

External Pilot Controls

Lift Outlet

Ride Outlet

Lift Outlet

Ride Outlet

SupplyExh

ExhSupply

OFF (OUT)

ON (IN)

Electrical Switch Up

Electrical Switch Down

Outlet #4

Outlet #2

SupplyExh

ExhOutlet #4

Outlet #2

Supply

Pressurized

Outlet #4

Outlet #2

SupplyExh

Exh

No Pressure

Outlet #4

Outlet #2

Supply

Electrical Switch Control

LOAD-TAMER™ Air Control ModulePlastic Housing Mount

Page 7: Pneumatic Products...LT113HD1LPA Mechanical 1/4" 0 F to 120 F .83 Cv Part Number Voltage Port Size Temperature Flow LT113RA1RPA 12VDC 1/8" 0 F to 120 F .75 Cv LT113SA1RPA 24VDC 1/8"

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatics

91

Catalog 0650-E

Common Part Numbers

Flat Plate Mount

Part Number Voltage Port Size Temperature Flow

LT112PA1LPA Mechanical 1/8" 0°Fto120°F .2Cv

LT112HD1LPA Mechanical 1/4" 0°Fto120°F .83Cv

Part Number Voltage Port Size Temperature Flow

LT112RA1RPA 12VDC 1/8" 0°Fto120°F .75Cv

LT112SA1RPA 24VDC 1/8" 0°Fto120°F .75Cv

LT112MA1RPA 12VDC 1/8" -20°Fto120°F .83Cv

LT112NA1RPA 24VDC 1/8" -20°Fto120°F .83Cv

LT112JD1RPA 12VDC 1/4" 0°Fto120°F 1.4Cv

LT112KD1RPA 24VDC 1/4" 0°Fto120°F 1.4Cv

Part Number Voltage Port Size Temperature Flow

LT112VA1LPA RemotePilot 1/8" -20°Fto120°F .75Cv

Push / Pull Control

Electrical Switch Control

External Pilot Controls

J, K R, S, M, N

Outlet #4

Outlet #2

SupplyExh

ExhOutlet #4

Outlet #2

Supply

Electrical Switch Up

Electrical Switch Down

Pressurized

Outlet #4

Outlet #2

SupplyExh

Exh

No Pressure

Outlet #4

Outlet #2

Supply

H P

LOAD-TAMER™ Air Control ModuleFlat Plate Mount

Lift Outlet

Ride Outlet

Lift Outlet

Ride Outlet

SupplyExh

ExhSupply

OFF (IN)

ON (OUT)

Page 8: Pneumatic Products...LT113HD1LPA Mechanical 1/4" 0 F to 120 F .83 Cv Part Number Voltage Port Size Temperature Flow LT113RA1RPA 12VDC 1/8" 0 F to 120 F .75 Cv LT113SA1RPA 24VDC 1/8"

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatics

92

L Bracket Mount

Part Number Voltage Port Size Temperature Flow

LT113PA1LPA Mechanical 1/8" 0°Fto120°F .2Cv

LT113HD1LPA Mechanical 1/4" 0°Fto120°F .83Cv

Part Number Voltage Port Size Temperature Flow

LT113RA1RPA 12VDC 1/8" 0°Fto120°F .75Cv

LT113SA1RPA 24VDC 1/8" 0°Fto120°F .75Cv

LT113MA1RPA 12VDC 1/8" -20°Fto120°F .83Cv

LT113NA1RPA 24VDC 1/8" -20°Fto120°F .83Cv

LT113JD1RPA 12VDC 1/4" 0°Fto120°F 1.4Cv

LT113KD1RPA 24VDC 1/4" 0°Fto120°F 1.4Cv

Part Number Voltage Port Size Temperature Flow

LT113VA1LPA RemotePilot 1/8" -20°Fto120°F .75Cv

Push / Pull Control

Electrical Switch Control

External Pilot Controls

Catalog 0650-E

Common Part Numbers

Lift Outlet

Ride Outlet

Lift Outlet

Ride Outlet

SupplyExh

ExhSupply

OFF (OUT)

ON (IN)

Electrical Switch Up

Electrical Switch Down

Outlet #4

Outlet #2

SupplyExh

ExhOutlet #4

Outlet #2

Supply

Pressurized

Outlet #4

Outlet #2

SupplyExh

Exh

No Pressure

Outlet #4

Outlet #2

Supply

J, KR, S, M, N

H P

LOAD-TAMER™ Air Control ModuleL Bracket Mount

Page 9: Pneumatic Products...LT113HD1LPA Mechanical 1/4" 0 F to 120 F .83 Cv Part Number Voltage Port Size Temperature Flow LT113RA1RPA 12VDC 1/8" 0 F to 120 F .75 Cv LT113SA1RPA 24VDC 1/8"

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatics

93

LOAD-TAMER™ Air Control ModuleSpecifications, Kits & Accessories

Catalog 0650-E

Technical Data

!

AirSupply

Load Tamer Load Tamer

Battery

GroundLoad

Spring

1

2

AirSupply

Battery

GroundLoadBag

1

24

Lift Bag

Typical InstallationsAir Ride / Spring Lift Air Ride / Air Lift

SpecificationsPortSizes(excludingPre-plumbedPorts): Valve Option P, E, T, R, S, M, & N Inlet ....................................................................1/8 NPTF Outlets ...............................................................1/8 NPTF

Valve Option H, J & K Inlet ....................................................................1/4 NPTF Outlets ...............................................................1/4 NPTF

Maximum Operating Pressure ....................160 PSIG (11 bar)

Valve Option P, E, T, R, S, J, K & H Operating Temperature .............. 0°F to 120°F (-18°C to 49°C)

Valve Option M, N & V Operating Temperature ........... -20°F to 120°F (-28°C to 49°C)

Flow Rating P & T ..........................................................................0.20 Cv R & S ..........................................................................0.75 Cv J & K ..........................................................................1.40 Cv H, M, N & V ..................................................................0.83 Cv

Gauge Scale ............................................................ 160 PSIG

Lamp Voltage .....................................................................12V

Net Weight ........................................1/8, 1 lb. 14 oz. (0.85 kg)

1/4, 2 lb. 13 oz. (1.28 kg)

NOTES: All units equipped with pressure regulator knob.

CAUTION:If it is possible that the ambient temperature may fall below freezing, the medium must be moisture free to prevent internal damage or unpredictable behavior.

Kits & Accessories Item Part No. Description Valve Option

B523177 Plastic Housing P,T,R,S,M,N B52317701 Plastic Housing V SBCF0476 Flat Plate P,T,R,S,M,N 1 SBCF047601 Flat Plate H,V SBCF047602 Flat Plate J,K SBCF0462 L Bracket P,T,R,S,M,N SBCF046201 L Bracket H,V SBCF046202 L Bracket J,K

2 P0328401 Lighted Gauge

14R013FC 1/8"Regulator 3 14R1C00094 1/8"LowTempRegulator 05R113A 1/4"Regulator

ApplicationThe LOAD-TAMER™ is engineered for vehicular applications such as air suspension systems and axle lift installations, where the LOAD-TAMER™ control panel provides a convenient means of manually controlling the system. Control panel design provides for ease of mounting in the operator’s compartment.

*ContactParkerPneumaticDivisionforallotherfeatures

Page 10: Pneumatic Products...LT113HD1LPA Mechanical 1/4" 0 F to 120 F .83 Cv Part Number Voltage Port Size Temperature Flow LT113RA1RPA 12VDC 1/8" 0 F to 120 F .75 Cv LT113SA1RPA 24VDC 1/8"

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatics

94

Catalog 0650-E

DimensionsAir Control ModuleLOAD-TAMER™

1.50(38)

3.34(85)

P

1.50(38)

3.34(85)

T

1.50(38)

3.29(83)

V M, N

J, KH

1.65(42)

4.49(114)

1.65(42)

3.51(89)

1.50(38)

3.29(83)

R, S

1.50(38)

3.29(83)

2.64(67)

7.05(179)

4.86(123)

6.75(171)

6.13(156)

0.6 (15)

3.88(99)

4.50(114)

2.50(64)

4.50(114)

6.75(171)

Plastic Housing L Bracket

Flat Plate

Dimensions

Note: Letters indicate Valve Option.