PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5 ...

19
Elyette Martin, Antonio Castellon, Pavel Pospisil PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland (Part of Philip Morris International group of companies) Biovia London 8 June 2017 www.pmiscience.com

Transcript of PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5 ...

Page 1: PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5 ...

Elyette Martin, Antonio Castellon, Pavel PospisilPMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland

(Part of Philip Morris International group of companies)

Biovia London 8 June 2017

www.pmiscience.com

Page 2: PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5 ...

2PMI R&D, Neuchatel, Switzerland

Page 3: PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5 ...

3

Aerosol

Some of these constituents

are categorized as

harmful and potentially

harmful constituents (HPHCs)

Distillation / Pyrolysis / Combustion

>800°C

more than

6000 constituents

Heating not Burning

<350°C

reduced level of

constituents

Reduced-Risk Products (“RRPs”) is the term we use to refer to products that present, arelikely to present, or have the potential to present less risk of harm to smokers whoswitch to these products versus continued smoking. We have a range of RRPs in variousstages of development, scientific assessment and commercialization. Because our RRPsdo not burn tobacco, they produce far lower quantities of harmful and potentiallyharmful compounds than found in cigarette smoke.

Page 4: PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5 ...

4

Aerosols are analyzed for

HPHCs.

Chemical and

Spectra RegistryStructural

Identification

Smoking machines generate aerosols that are trapped

and collected.

Studies to advance scientific and medical knowledge are performed.

Toxicological and Clinical assessments are done.

Constituents are deposited in

database, clustered and calculated.

Computationalchemistry

Systems Toxicology,Clinics

Aerosol

Analytical chemistry

PP used for: REPORTING

CASI UCSD

Page 5: PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5 ...

5

Spectra

Database

Compound

Database

Martin et al., J Cheminform. 2012; 4(1)

Page 6: PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5 ...

6

Protocol to determine to which

chemical classes a compound belongs

Page 7: PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5 ...

7

logP, water solubility, ADMET …

Page 8: PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5 ...

8

IUPAC name

Page 9: PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5 ...

9

PubChem CID

ChemSpider CSID

Page 10: PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5 ...

10

CASI 2.1 Ruby Application processes

PRE PROCESSOR

POST PROCESSOR

CASI APEX Portal

INPUT

. . .

Experimental files

casi_input.txt

Concentrations_ISTDs.txt

spectra.HPJ

concentrations.txt

(1)

(2)

(3)

master.txt

warning.txt

warning-area-dcompounds.txt

input-postprocess.txt

Pipeline Pilot

Protocol

casi_report_ntds.txtcasi_report.sdf

VolatilePolar

Nonpolar

Knorr et al., Anal Chem. 2013; 85(23)

Page 11: PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5 ...

11

Page 12: PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5 ...

12

2D standardization of compounds

Updating data in CASI by id codes and pictures of molecules

Page 13: PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5 ...

13

Calculation of Boiling Point using PP and ACD/Labs

Page 14: PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5 ...

14

Determination of which internal

standard to use to

semi-quantify compounds

concentrations

Page 15: PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5 ...

15

Example of script used in

Non Polar sub-protocol

Page 16: PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5 ...

16

List of protocols used via webport

Page 17: PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5 ...

17

This protocol is used to prepare a sequence of input

to the analytical instrument

and

to create a file to automatically print labels on vials

Page 18: PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5 ...

18

Page 19: PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5 ...

19

At Philip Morris R&D we use Biovia Pipeline Pilot scripts to automate processes

in analytical and computational chemistry.

We provide users with over 15 Webport scripts helping them sequence

processing and reporting.

Thank you for your attention.

Questions?