PLS-CADD DRAWING - VELCO · PDF filepls-cadd drawing 850+00 855+00 860+00 865+00 220 240 260...

5

Transcript of PLS-CADD DRAWING - VELCO · PDF filepls-cadd drawing 850+00 855+00 860+00 865+00 220 240 260...

Page 1: PLS-CADD DRAWING - VELCO · PDF filepls-cadd drawing 850+00 855+00 860+00 865+00 220 240 260 280 300 320 340 360 380 400 420 440 460 480 500 520 540 560 580 600
Page 2: PLS-CADD DRAWING - VELCO · PDF filepls-cadd drawing 850+00 855+00 860+00 865+00 220 240 260 280 300 320 340 360 380 400 420 440 460 480 500 520 540 560 580 600

PLS-CADD DRAWING

850+00

855+00

860+00

865+00

220

240

260

280

300

320

340

360

380

400

420

440

460

480

500

520

540

560

580

600

620

640

660

220

240

260

280

300

320

340

360

380

400

420

440

460

480

500

520

540

560

580

600

620

640

660

PI -68°18'05"

PI 27°52'06"

PI -34°36'23"

381 RIVER X-ING LATTICE STICK_RIVER CROSSING

STA=851+61.3

EXISTING LATTIC TOWER

N381-1 LINE_381_VERT.POL

STA=854+52.7

117 FT STEEL POLE

381 TAKEOFF VERNONSUBPO.080

STA=855+42.7

340 TAKEOFF VERNONSUBPO.080

STA=860+42.7

117 FT STEEL POLE

N340-3 LINE_340_VERT.POL

STA=861+32.9

117 FT STEEL POLE

S_106FT_STEEL_DE.POL

STA=868+14.3

1-S

318.2, 291.4

90.0

90.2 681.4

REV

TEMPORARY ISSUE TRACKING BLOCK

BYDATE DESCRIPTION

APPROVED BY:

SHEET NUMBER:

DATE:

SCALE:

CHECKED BY:

DRAWN BY:

REV. FILE:

DATE

DRDATEREV DESCRIPTIONCK

EDGE OF ROW

360 CL

340 CLEXISTING ACCESS ROAD

340 STRUCTURE

RIGHT OFFSET GROUNDELEVATION (+30 FT)

LEGEND

LEFT OFFSET GROUNDELEVATION (-30 FT)

OPTICAL STATIC WIRE

STEEL STATIC WIRE

CONDUCTOR

WIRE CROSSING(NOT SHOWN ONPROFILE)

TYPICAL TWO POLESTRUCTURE

TYPICAL THREE POLE GUYED STRUCTURE

BURIED ANCHOR

#124

#125

TYPICAL STEEL POLE STRUCTURE

952.2 TP

950.2 W

IRE

953.4 W

IRE

955.4 TP

EDGE OF ROW

360 CL

340 CLEXISTING ACCESS ROAD

340 STRUCTURE

RIGHT OFFSET GROUNDELEVATION (+30 FT)

LEGEND

LEFT OFFSET GROUNDELEVATION (-30 FT)

OPTICAL STATIC WIRE

STEEL STATIC WIRE

CONDUCTOR

WIRE CROSSING(NOT SHOWN ONPROFILE)

TYPICAL TWO POLESTRUCTURE

TYPICAL THREE POLE GUYED STRUCTURE

BURIED ANCHOR

#124

#125

TYPICAL STEEL POLE STRUCTURE

952.2 TP

950.2 W

IRE

953.4 W

IRE

955.4 TP

A 09/20/07 TSB/KKM ISSUED FOR FILING

VERMONT ELECTRIC POWER CO., INC.RUTLAND, VERMONT

RLN/SKF

TSB/KKMAS SHOWN

VERNON - COOLIDGE

PROPOSED VERNON SUBSTATION CONNECTION

PROFILE

23101_ALT_VERNON_SUB_091407

VERNON LINES 1

**NOTE**SEE DRAWING "DETAIL 1"FOR PLAN VIEW

VERT. SCALE

HORIZ. SCALE

40.0 FT.

200.0 FT.

Page 3: PLS-CADD DRAWING - VELCO · PDF filepls-cadd drawing 850+00 855+00 860+00 865+00 220 240 260 280 300 320 340 360 380 400 420 440 460 480 500 520 540 560 580 600

PLS-CADD DRAWING

930+00

935+00

940+00

945+00

220

240

260

280

300

320

340

360

380

400

420

440

460

480

500

520

540

560

580

600

620

640

660

220

240

260

280

300

320

340

360

380

400

420

440

460

480

500

520

540

560

580

600

620

640

660

PI 38°42'32"

PI 41°08'53"

379 TAKEOFF VERNONSUBPO.080

STA=930+22.9

N379-1 LINE_379_VERT.POL

STA=931+12.9

117 FT STEEL POLE

379 RIVER X-ING LATTICE STICK_RIVER CROSSING

STA=934+49.2

EXISTING LATTCE TOWER

N360-1 345KV_116FT.POL

STA=939+49.2

116 FT STEEL POLE

N360-2 345KV_106FT.POL

STA=945+48.3

144 - VY FEED VERNONSUBPO.080

STA=947+74.2

90.0

336.3

599.1225.8

REV

TEMPORARY ISSUE TRACKING BLOCK

BYDATE DESCRIPTION

APPROVED BY:

SHEET NUMBER:

DATE:

SCALE:

CHECKED BY:

DRAWN BY:

REV. FILE:

DATE

DRDATEREV DESCRIPTIONCK

EDGE OF ROW

360 CL

340 CLEXISTING ACCESS ROAD

340 STRUCTURE

RIGHT OFFSET GROUNDELEVATION (+30 FT)

LEGEND

LEFT OFFSET GROUNDELEVATION (-30 FT)

OPTICAL STATIC WIRE

STEEL STATIC WIRE

CONDUCTOR

WIRE CROSSING(NOT SHOWN ONPROFILE)

TYPICAL TWO POLESTRUCTURE

TYPICAL THREE POLE GUYED STRUCTURE

BURIED ANCHOR

#124

#125

TYPICAL STEEL POLE STRUCTURE

952.2 TP

950.2 W

IRE

953.4 W

IRE

955.4 TP

EDGE OF ROW

360 CL

340 CLEXISTING ACCESS ROAD

340 STRUCTURE

RIGHT OFFSET GROUNDELEVATION (+30 FT)

LEGEND

LEFT OFFSET GROUNDELEVATION (-30 FT)

OPTICAL STATIC WIRE

STEEL STATIC WIRE

CONDUCTOR

WIRE CROSSING(NOT SHOWN ONPROFILE)

TYPICAL TWO POLESTRUCTURE

TYPICAL THREE POLE GUYED STRUCTURE

BURIED ANCHOR

#124

#125

TYPICAL STEEL POLE STRUCTURE

952.2 TP

950.2 W

IRE

953.4 W

IRE

955.4 TP

A 09/20/07 TSB/KKM ISSUED FOR FILING

VERMONT ELECTRIC POWER CO., INC.RUTLAND, VERMONT

RLN/SKF

TSB/KKMAS SHOWN

VERNON - COOLIDGE

PROPOSED VERNON SUBSTATION CONNECTION

PROFILE

23101_ALT_VERNON_SUB_091407

VERNON LINES 2

**NOTE**SEE DRAWING "DETAIL 1"FOR PLAN VIEW

VERT. SCALE

HORIZ. SCALE

40.0 FT.

200.0 FT.

Page 4: PLS-CADD DRAWING - VELCO · PDF filepls-cadd drawing 850+00 855+00 860+00 865+00 220 240 260 280 300 320 340 360 380 400 420 440 460 480 500 520 540 560 580 600

PLS-CADD DRAWING

980+00

985+00

220

240

260

280

300

320

340

360

380

400

420

440

460

480

500

520

540

560

580

600

620

640

660

220

240

260

280

300

320

340

360

380

400

420

440

460

480

500

520

540

560

580

600

620

640

660

PI 48°32'40"

PI -46°36'48"

381 RIVER X-ING LATTICE STICK_RIVER CROSSING

STA=851+61.3

EXISTING LATTIC TOWER

VERNON-KEENE #2-1.070.POL

STA=983+98.5

N115-7 115KV_58FT.POL

STA=987+51.4

N115-6 115KV_58FT.POL

STA=988+76.9

318.2, 291.4

352.9 125.5

REV

TEMPORARY ISSUE TRACKING BLOCK

BYDATE DESCRIPTION

APPROVED BY:

SHEET NUMBER:

DATE:

SCALE:

CHECKED BY:

DRAWN BY:

REV. FILE:

DATE

DRDATEREV DESCRIPTIONCK

EDGE OF ROW

360 CL

340 CLEXISTING ACCESS ROAD

340 STRUCTURE

RIGHT OFFSET GROUNDELEVATION (+30 FT)

LEGEND

LEFT OFFSET GROUNDELEVATION (-30 FT)

OPTICAL STATIC WIRE

STEEL STATIC WIRE

CONDUCTOR

WIRE CROSSING(NOT SHOWN ONPROFILE)

TYPICAL TWO POLESTRUCTURE

TYPICAL THREE POLE GUYED STRUCTURE

BURIED ANCHOR

#124

#125

TYPICAL STEEL POLE STRUCTURE

952.2 TP

950.2 W

IRE

953.4 W

IRE

955.4 TP

EDGE OF ROW

360 CL

340 CLEXISTING ACCESS ROAD

340 STRUCTURE

RIGHT OFFSET GROUNDELEVATION (+30 FT)

LEGEND

LEFT OFFSET GROUNDELEVATION (-30 FT)

OPTICAL STATIC WIRE

STEEL STATIC WIRE

CONDUCTOR

WIRE CROSSING(NOT SHOWN ONPROFILE)

TYPICAL TWO POLESTRUCTURE

TYPICAL THREE POLE GUYED STRUCTURE

BURIED ANCHOR

#124

#125

TYPICAL STEEL POLE STRUCTURE

952.2 TP

950.2 W

IRE

953.4 W

IRE

955.4 TP

A 09/20/07 TSB/KKM ISSUED FOR FILING

VERMONT ELECTRIC POWER CO., INC.RUTLAND, VERMONT

RLN/SKF

TSB/KKMAS SHOWN

VERNON - COOLIDGE

PROPOSED VERNON SUBSTATION CONNECTION

PROFILE

23101_ALT_VERNON_SUB_091407

VERNON LINES 3

**NOTE**SEE DRAWING "DETAIL 1"FOR PLAN VIEW

VERT. SCALE

HORIZ. SCALE

40.0 FT.

200.0 FT.

Page 5: PLS-CADD DRAWING - VELCO · PDF filepls-cadd drawing 850+00 855+00 860+00 865+00 220 240 260 280 300 320 340 360 380 400 420 440 460 480 500 520 540 560 580 600

PLS-CADD DRAWING

30+00

35+00

220

240

260

280

300

320

340

360

380

400

420

440

460

480

500

520

540

560

580

600

620

640

660

220

240

260

280

300

320

340

360

380

400

420

440

460

480

500

520

540

560

580

600

620

640

660

PI 20°47'22"

PI -34°36'06"

360 TAKEOFF VERNONSUBPO.080

STA=30+17.5

N360-3 LINE_360_VERT.POL

STA=31+07.7

117 FT STEEL POLE

1-SW SW_113FT_STEEL_DE.POL

STA=37+96.2

90.2688.5

REV

TEMPORARY ISSUE TRACKING BLOCK

BYDATE DESCRIPTION

APPROVED BY:

SHEET NUMBER:

DATE:

SCALE:

CHECKED BY:

DRAWN BY:

REV. FILE:

DATE

DRDATEREV DESCRIPTIONCK

EDGE OF ROW

360 CL

340 CLEXISTING ACCESS ROAD

340 STRUCTURE

RIGHT OFFSET GROUNDELEVATION (+30 FT)

LEGEND

LEFT OFFSET GROUNDELEVATION (-30 FT)

OPTICAL STATIC WIRE

STEEL STATIC WIRE

CONDUCTOR

WIRE CROSSING(NOT SHOWN ONPROFILE)

TYPICAL TWO POLESTRUCTURE

TYPICAL THREE POLE GUYED STRUCTURE

BURIED ANCHOR

#124

#125

TYPICAL STEEL POLE STRUCTURE

952.2 TP

950.2 WIRE

953.4 WIRE

955.4 TP

EDGE OF ROW

360 CL

340 CLEXISTING ACCESS ROAD

340 STRUCTURE

RIGHT OFFSET GROUNDELEVATION (+30 FT)

LEGEND

LEFT OFFSET GROUNDELEVATION (-30 FT)

OPTICAL STATIC WIRE

STEEL STATIC WIRE

CONDUCTOR

WIRE CROSSING(NOT SHOWN ONPROFILE)

TYPICAL TWO POLESTRUCTURE

TYPICAL THREE POLE GUYED STRUCTURE

BURIED ANCHOR

#124

#125

TYPICAL STEEL POLE STRUCTURE

952.2 TP

950.2 WIRE

953.4 WIRE

955.4 TP

A 09/20/07 TSB/KKM ISSUED FOR FILING

VERMONT ELECTRIC POWER CO., INC.RUTLAND, VERMONT

RLN/SKF

TSB/KKMAS SHOWN

VERNON - COOLIDGE

PROPOSED VERNON SUBSTATION CONNECTION

PROFILE

23101_ALT_VERNON_SUB_091407

VERNON LINES 4

**NOTE**SEE DRAWING "DETAIL 1"FOR PLAN VIEW

VERT. SCALE

HORIZ. SCALE

40.0 FT.

200.0 FT.