PLMR Calibration Valerio Paruscio Dr Jeff Walker University of Melbourne.

26
PLMR Calibration Valerio Paruscio Dr Jeff Walker University of Melbourne

Transcript of PLMR Calibration Valerio Paruscio Dr Jeff Walker University of Melbourne.

Page 1: PLMR Calibration Valerio Paruscio Dr Jeff Walker University of Melbourne.

PLMR Calibration

Valerio ParuscioDr Jeff Walker

University of Melbourne

Page 2: PLMR Calibration Valerio Paruscio Dr Jeff Walker University of Melbourne.

Outline

• Admissible error in brightness temperature measurement

• Available data for calibration

• Calibration options and recommendation

Page 3: PLMR Calibration Valerio Paruscio Dr Jeff Walker University of Melbourne.

Model Sensitivity Assessment

How accurate has the Brightness Temperature measurement to be in order to have a Moisture content error less than 4%?

Hypothesis:• Roughness = 0.2• SS Albedo = 0.05• Soil Type = Silt clay loam

Page 4: PLMR Calibration Valerio Paruscio Dr Jeff Walker University of Melbourne.

Variables:• Moisture Content (0.05-0.4) %v/%v• Vegetation Water Content (03)kg/m2

• Soil Temperature (280315)K• Incidence Angle (040)

Model Sensitivity Assessment

How accurate has the Brightness Temperature measurement to be in order to have a Moisture content error less than 4%?

Page 5: PLMR Calibration Valerio Paruscio Dr Jeff Walker University of Melbourne.

Graphs Tb sensitivity

Page 6: PLMR Calibration Valerio Paruscio Dr Jeff Walker University of Melbourne.

cold 4.5 3.2 6.8 7.3

hot 5.0 3.6 7.6 8.2

cold 2.2 1.3 3.4 2.9

hot 2.5 1.5 3.8 3.3

0 40 0 40

3 Vegeta

tion

Wate

r Conte

nt

dry wet

0

Moisture Content

Incidence Angle

Soil

Tem

pera

ture

cold 4.5 6.4 6.7 7.0

hot 5.0 7.2 7.6 7.9

cold 2.2 2.6 3.4 2.8

hot 2.5 2.9 3.8 3.2

0 40 0 40

Moisture Content

dry wet

Incidence Angle

Soil

Tem

per

atu

re 0

Veg

etati

on

Wate

r Conte

nt

3

1.3

2.2

H polarization

error (K)

V polarization

error (K)

Page 7: PLMR Calibration Valerio Paruscio Dr Jeff Walker University of Melbourne.

Critical scenarios• High value of Vegetation Water Content• High Incidence Angle• Dry Soil

Max Tb error permitted =

Most common scenarios• Low value of Vegetation Water Content

Max Tb error permitted =

Commonly Tb error up to 8K can be tolerated

4.7K (Hpol)2.7K (Vpol)

2.2K (Hpol)1.3K (Vpol)

Page 8: PLMR Calibration Valerio Paruscio Dr Jeff Walker University of Melbourne.

Available data for

calibration• Box pre and post flight

(~300K)

act

ual

measured

Page 9: PLMR Calibration Valerio Paruscio Dr Jeff Walker University of Melbourne.

Available data for

calibration• Box pre and post flight

(~300K)

• Sky pre and post flight (~5K)

act

ual

measured

Page 10: PLMR Calibration Valerio Paruscio Dr Jeff Walker University of Melbourne.

Box and Sky Brightness Temperature

Pre flight Box

Pre flight Sky Post flight Sky

Post flight Box

Page 11: PLMR Calibration Valerio Paruscio Dr Jeff Walker University of Melbourne.

Available data for

calibration• Box pre and post flight

(~300K)

• Sky pre and post flight (~5K)

• Water in flight (~110K)

act

ual

measured

Page 12: PLMR Calibration Valerio Paruscio Dr Jeff Walker University of Melbourne.

Temperature and Conductivity spatial series

Page 13: PLMR Calibration Valerio Paruscio Dr Jeff Walker University of Melbourne.

Temperature and Conductivity time series

Page 14: PLMR Calibration Valerio Paruscio Dr Jeff Walker University of Melbourne.

Transect–Buoy data comparision

Page 15: PLMR Calibration Valerio Paruscio Dr Jeff Walker University of Melbourne.

Week 1 Week 2 Week 3 Week 4

Thermal Infrared data over the lake

Mon

Tue

Wed

Thu

Fri

Page 16: PLMR Calibration Valerio Paruscio Dr Jeff Walker University of Melbourne.

Available data for

calibration• Box pre and post flight

(~300K)

• Sky pre and post flight (~5K)

• Water in flight (~110K)

• Sky in flight (~5K)

act

ual

measured

Page 17: PLMR Calibration Valerio Paruscio Dr Jeff Walker University of Melbourne.

Available data for calibration

1. Box pre flight (~300K)

2. Sky pre flight (~5K)

3. Water in flight (~110K)

4. Sky in flight (~5K)

5. Box post flight (~300K)

6. Sky post flight (~5K)

act

ual

measured

Page 18: PLMR Calibration Valerio Paruscio Dr Jeff Walker University of Melbourne.

Calibration options• 6 points (all)

• 4 points/2 points (box & sky from the ground)

• 3 points (box and water)

Page 19: PLMR Calibration Valerio Paruscio Dr Jeff Walker University of Melbourne.

Calibration lines (6 beams, 2 polarizations)

Page 20: PLMR Calibration Valerio Paruscio Dr Jeff Walker University of Melbourne.

Check the 4 pt calibration with water ponit

H polV pol

Page 21: PLMR Calibration Valerio Paruscio Dr Jeff Walker University of Melbourne.

Check the 3 pt calibration with in flight sky ponit

V pol H pol

Page 22: PLMR Calibration Valerio Paruscio Dr Jeff Walker University of Melbourne.

Variation in Tb measurement passing from the 4 points cal to

the 3 points cal

Page 23: PLMR Calibration Valerio Paruscio Dr Jeff Walker University of Melbourne.

Time series of slope & offset (4 pts)

• From 4 pt

V-Pol

-45

-40

-35

-30

-25

-20

-15

-10

-5

0

30/10/05 4/11/05 9/11/05 14/11/05 19/11/05 24/11/05 29/11/05

Date

Off

se

t (K

)

V3L

V2L

V1L

V1R

V2R

V3R

H-Pol

-40

-35

-30

-25

-20

-15

-10

-5

0

5

30/10/05 4/11/05 9/11/05 14/11/05 19/11/05 24/11/05 29/11/05

Date

Off

se

t (K

)

H3L

H2L

H1L

H1R

H2R

H3R

V-Pol

0.95

0.97

0.99

1.01

1.03

1.05

1.07

1.09

1.11

1.13

1.15

30/10/05 4/11/05 9/11/05 14/11/05 19/11/05 24/11/05 29/11/05

Date

Slo

pe

(K

/K)

V3L

V2L

V1L

V1R

V2R

V3R

H-Pol

0.95

0.97

0.99

1.01

1.03

1.05

1.07

1.09

1.11

1.13

1.15

30/10/05 4/11/05 9/11/05 14/11/05 19/11/05 24/11/05 29/11/05

Date

Slo

pe

(K

/K)

H3L

H2L

H1L

H1R

H2R

H3R

Page 24: PLMR Calibration Valerio Paruscio Dr Jeff Walker University of Melbourne.

Variation in Tb measurement passing from the 4 points cal to

the 2 points cal

Page 25: PLMR Calibration Valerio Paruscio Dr Jeff Walker University of Melbourne.

Error using a unique 4 pt calibration instead of a daily one

Page 26: PLMR Calibration Valerio Paruscio Dr Jeff Walker University of Melbourne.

Conclusion

• Recommendation this campaign

V pol 4 pt dailyH pol 4 pt daily (or unique)

next campaign V pol 4 pt daily, 3 pt(?)

H pol 4 pt/2 pt daily (or unique)