Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

35
Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B

Transcript of Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

Page 1: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

Plant Safety and Fire Protection

Pharmaceutical Industrial Management (Pharm 5211): Section B

Page 2: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

Introduction

Accident prevention & fire protection – part of any industry

Extremely important in bulk drug manufacture (synthetic, biologic or microbiological)

Begins with design of plants (buildings, equipment and processes)

Plants – regularly examined to decide upon safety and fire protection.

Majority of present day accidents and fires due to human causes.

Now, the objective is to remove human factors from fire hazards.

Page 3: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

Legislation

State regulations governing safety and fire protection measures for

buildings, equipment and processes.

Necessary to examine that these regulations are being followed.

State compensation laws require compensation insurance and reports

of meeting these provisions.

Page 4: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

The industrial plant: Location

Depends on many factors e.g., raw material supplies, transportation facilities and labour supply

Safety and fire protection is particularly important where corrosive, poisonous and explosive materials are being handled or produced.

Make sure that location of plant offers no undue danger to adjacent life and property.

State laws – consulted and satisfied.

Page 5: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

The industrial plant: Arrangement of buildings

To permit economic production as well as to provide safety and fire protection by constructions e.g., fire walls, barricades, etc.

efforts to limit the height of factory buildings, to provide good separation (50 ft or more between important units), to minimize conflagration (great and destructive fires) areas by fire stops.

Buildings for hazardous occupancies or explosives – segregated, isolated or barricaded to prevent life loss and property damage.

Page 6: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

The industrial plant: Arrangement of buildings

Distance between buildings depends on type of construction, area, height, importance of unit to existing plant, hazards of processes, land available for present manufacture and future extension, costs involved and available protection.

Also, the extent of exposure from outside properties not under the control of plant influences….

Minimum overhead clearances for footways, roads, rail roads, etc.

Page 7: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

The industrial plant: Arrangement of buildings

Water supply for fire protection from at least 2 sources:

Primary supply – automatic, of good pressure, limited capacity, connection from a reliable public water system or a gravity tank of 100,000 gal. elevated at 125 ft.

Secondary supply – fire pumps located in an isolated or properly protected fire resistive pump house with an unlimited suction supply. If natural water supply unavailable, concrete reservoirs with adequate filling connections are necessary.

Page 8: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

The industrial plant: Fire mains, hydrants & hoses

An independent system of underground fire mains supplying sprinkler systems and yard hydrants

Size of mains, branches to individual hydrants and the way they are coated, insulated and laid in the underground should be based on specifications.

Hydrants are located such that 2 streams are available for a building.

Standard single jacketed, cotton, rubber-lined mill yard is preferred because of its flexibility and low friction loss.

Page 9: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

The industrial plant: Fire alarm equipment

Fire alarm systems for promptly notifying the fire brigade and exit of employees

Should operate on closed, electrically supervised circuits

Installed in conspicuous locations and mounted to resist vibration

Inside buildings, located near exits.

Page 10: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

Buildings: Type of construction

Should not be of frame construction

Non-combustible or fire resistant construction is preferred

Construction of door openings, windows and walls such that fire cannot spread from one building to another.

Page 11: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

Buildings: Type of construction

For large floor areas or combustible construction, fire wall cutoffs (of at least 13 in.), door openings protected with single or double automatic fire doors.

For multi-storied buildings, each floor entirely cutoff from other floors & all openings (e.g., stairways) equipped with automatic fire doors.

Page 12: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

Buildings: Exits

Exits of ample capacity – provided to accommodate employees in case of fire and panic

Exits should enable them to reach a place of safety outside working building.

Should have at least 2 means of exits from each storey.

Page 13: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

Buildings: Lighting

Factors affecting human eyes must be considered in design and installation of lighting.

These are reflection, absorption, distribution, diffusion, intensity, steadiness, colour, and glare.

Page 14: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

Buildings: Lighting

Height, spacing, size of lamps and type of reflection – considered.

Light from above is better than light from side or windows only.

4 artificial lighting systems: direct, indirect, semi-indirect & local, depends on nature of works.

Page 15: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

Buildings: Colour

In painting walls, floors, ceilings, machines, machine parts, piping, etc.

Inferior lighting – improved by proper use of various colours

Eye strain – reduced by scientific blending of backgrounds

Hazardous machine parts, dangerous materials, traffic hazards, warning signs and protective equipment – designed with standard safety colour code.

Page 16: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

Buildings: Ventilation

Depends on amount and distribution of air supply, temperature, humidity, motion, velocity, odours, dust, bacteria and toxic or flammable vapours.

Proper ventilation for all people in a confined space Removal of harmful or dangerous substances in the air

Page 17: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

Buildings: Ventilation

Deficiency of oxygen or high humidity results in excessive fatige

Air supply system whether by windows, a forced draft system, a suction system or combination – depends on conditions.

For harmful or flammable dust or vapour, keep them below harmful or hazardous concentration.

Page 18: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

Buildings: Sanitation

Change rooms with lockers, wash rooms, lunch rooms and toilet facilities – adequate for all employees.

Hygiene among workers – to combat health hazards and for efficiency.

Shower baths for workmen if dirty or exposed to poisonous dust, fumes or vapours.

If necessary, special working clothes, supervise and provide washing facilities for these clothes.

A drinking water system meeting health codes and with regular chemical and bacteriological analysis.

Page 19: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

Buildings: Automatic sprinkler systems

The best, simple safeguard against loss of life and property by fire.

A device for distinguishing fire and automatically discharging water on fire

Automatic feature is secured through….

heat from the fire melting a soft solder compound

bursting the bulb due to expansion of liquid (bulb type sprinkler)

Page 20: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

Buildings: First aid fire extinguishers

For incipient fires & installed with other equipments e.g., sprinklers and inside hose.

Incipient fires are of 3 categories:

Class A fires – in ordinary combusting material where quenching and cooling effects of water is important

Class B fires – in oils, greases, flammable liquids, etc. where blanketing or smothering effect of extinguishing agent is important

Class C fires – in electrical equipment where non-conducting property of extinguishing agent is important

Page 21: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

Buildings: Equipment

Properly guarded and free from protecting shafts, exposed moving parts and projecting set screws.

Automatically fed machines – preferred and point of operation – adequately guarded.

Rolls or other equipments with moving parts – provided quick stopping devices (either automatic or manual)

Remote controls – for machines with explosive substances.

Suitable means for adequate cleaning without undue hazards

Pressure vessels – installed in accordance with Boiler Construction Code.

Page 22: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

Buildings: Guarding of general machinery

Adequate permanent or temporary protective appliances for new and existing machinery.

Guards – mostly metal, rarely wooden.

All belts and pulleys within 7 ft. of ground, platforms, stairs, etc. – to be protected against contact.

Detailed designs for passage through belts, passage over belts, protection against belt breakage, belt clearance, belt facing pulley speeds and maintenance, belt shifters and clutches.

No projecting set screws, bolts, keys, etc. on shafting pulleys, gears, etc. (unless protected by closed guard)

Page 23: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

Buildings:

RailingsTo provide protection against falling, slippings from elevated platforms,

walkways, etc.

Standard railing on all open sides and ends (if vertical drop of 4 ft./more)

Slipping hazardsIf grease, caustic, paraffin, etc. contribute to slippery condition, choice of

surfacing is important.

Nonslip materials e.g., feralum, lead, rubber matting, expanded metal should be inserted where necessary (especially at all dangerous hand-fed machine.

Page 24: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

Buildings: Floor plates, flush covers, trap doors, etc.

Abrupt minor changes in floor level - avoided.

Piping, valves, steam traps, etc. – should not project into footways.

For stairs, best angle – 350 (not exceeding 450)

height of rises – 7 in.

width of tread – 10 in.

Stairs are preferable to ladders. Portable ladders are unsafe on metal flooring, should be secured (e.g., by safety feet or holding).

Page 25: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

Buildings:

SkidsPermanent skids for receiving or storage of drums or barrels.

Should be planked solid between each pair of rails.

Clearance between ends of drums –not less than 12 in.

ProcessesHandle corrosive, poisonous or dangerous substances in closed equipment

If not possible, in case of poisonous dust or gas, special ventilation units should be considered.

Page 26: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

Buildings: Tanks, Vats, Pans, Location

For containers of hot, corrosive or dangerous liquids………

36 in. of separation – to routes passing along sides

72 in. of separation – to stations

72 in. wide – passage between 2 rooms or rows of open containers

No routes or stations directly below open containers.

Unused spaces below such tanks should be blocked and marked.

Page 27: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

Buildings: Flammable liquids

Storage and handling of volatile, flammable liquids – precautions to minimize hazards.

Inherent fire and explosion hazard depends on flush point, apparent ignition temperature, explosive range, vapour density, air diffusibility of the vapour in air, etc.

Combustion: chemical change with evolution of heat and light. Slow and rapid combustion, fire, apparent ignition temperature, flush point, flush fire, explosive range, vapour or dust explosion, explosion or detonation, pressure rupture, spontaneous combustion, decomposition

Page 28: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

Buildings: Location & arrangement of storage tanks for flammable liquids

Strength, capacity and location of storage tanks, vents, dikes and quick closing valves in pipe lines should be considered.

The most common method of storage is above-ground, outside-tank

Depending on construction, tanks are of 4 groups: group A, B, C & D

Three methods of handling are – by pumping, by gravity and by compressed air or inert gas.

Pumping is preferred to gravity discharge.

Page 29: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

Buildings: Static electricity

Generated from…….

handling materials – solids, liquids or gases

operation of equipment such as belt

Handling of dry granular substances e.g., sulphur in metal chutes

Flow of certain liquids in pipe lines.

Discharge in presence of flammable dusts or vapours is considered hazardous.

Page 30: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

Compressed gases in cylinders

Definite regulations must be met in filling and transporting.

Important precautions……. Extreme care in handling cylinders – don’t drop or strike against each other

Don’t tamper with safety devices on cylinders

Use special wrenches or tools (from manufacturers) on valves

Protect excessive rise in temperature and extremes of weather

Keep full cylinders separate from empty ones

Should have a conspicuous standard label indicating kind of gas; colour of label shows whether gas is inflammable, corrosive or inert.

Page 31: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

Dust explosion

Can occur in any combustible dust or any material that burns or oxidises including metallic dust.

Explosive range – below lower limit, no flame propagation; above this limit, burning but no explosion.

Degree of flammability depends on its moisture content and fineness.

The drier and finer the dust the greater its flammability.

Dilute below the lower limit of explosive range and immediately remove while in diluted state.

Keep the premises very clean; eliminate all sources of ignition.

Page 32: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

Special safety protection equipment

Use of protective equipment – secondary measure against injury and health hazards.

To protect head and eyes, use goggles, shields, helmets, hooks, maskes, hats, etc.

Use proper respiratory protective devices in breathing of poisonous gases and fumes or of oxygen-deficit atmosphere.

Use rubber or canvas gloves, rubber boots, aprons, shoes and other clothing to protect hands, arms, legs and feet.

Page 33: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

Safety and fire protection organization

A central committee:

chairman – Plant manager or Asstt. Plant manager

secretary – safety and fire protection supervisor

members – remainder of plant executive staff

Departmental committee:

chairman – head of the department

members – 4 men

Central committee takes care of general policies at central level.

Departmental committee is responsible in their departments.

Page 34: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

First aid

So that injured persons can be cared for in emergencies and until further treatment is secured.

Full time plant physician otherwise small industrial first aid units

Under care of a competent, all time available and trained person

Page 35: Plant Safety and Fire Protection Pharmaceutical Industrial Management (Pharm 5211): Section B.

Thank you For patience hearing!!