NORDSON BENELUX � MAASTRICHT � THE NETHERLANDS

Piston PumpLA 300

Manual P/N 7105256_05- English -

Edition 01/12

Page 2: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

Order numberP/N = Order number for Nordson articles

NoteThis is a Nordson corporation publication which is protected by copyright. Copyright � 2004.No part of this document may be photocopied, reproduced or translated to another language

without the prior written consent of Nordson Corporation. The information contained in this publication is subject to change without notice.

© 2012 All rights reserved.

TrademarksAccuJet, AeroCharge, Apogee, AquaGuard, Asymtek, Automove, Autotech, Baitgun, Blue Box, Bowtie, Build‐A‐Part, CanWorks, Century, CF,

CleanSleeve, CleanSpray, Color‐on‐Demand, ColorMax, Control Coat, Coolwave, Cross‐Cut, cScan+, Dage, Dispensejet, DispenseMate,

DuraBlue, DuraDrum, Durafiber, DuraPail, Dura‐Screen, Durasystem, Easy Coat, Easymove Plus, Ecodry, Econo‐Coat, e.DOT, EFD,

Emerald, Encore, ESP, e stylized, ETI‐stylized, Excel 2000, Fibrijet, Fillmaster, FlexiCoat, Flexi‐Spray, Flex‐O‐Coat, Flow Sentry, Fluidmove,

FoamMelt, FoamMix, Fulfill, GreenUV, HDLV, Heli‐flow, Helix, Horizon, Hot Shot, iControl, iDry, iFlow, Isocoil, Isocore, Iso‐Flo, iTRAX, JR,

KB30, Kinetix, LEAN CELL, Little Squirt, LogiComm, Magnastatic, March, Maverick, MEG, Meltex, Microcoat, Micromark, Micromedics,

MicroSet, Millenium, Mini Squirt, Moist‐Cure, Mountaingate, MultiScan, Nordson, Optimum, Package of Values, PatternView, PermaFlo,

PicoDot, PluraFoam, Porous Coat, PowderGrid, Powderware, Precisecoat, PRIMARC, Printplus, Prism, ProBlue, Prodigy, Pro‐Flo, ProLink,

Pro‐Meter, Pro‐Stream, RBX, Rhino, Saturn, Saturn with rings, Scoreguard, SC5, S. design stylized, Seal Sentry, Select Charge, Select Coat,

Select Cure, Signature, Slautterback, Smart‐Coat, Solder Plus, Spectrum, Speed‐Coat, Spraymelt, Spray Squirt, Super Squirt, SureBead,

Sure Clean, Sure Coat, Sure‐Max, Sure Wrap, Tela‐Therm, Tracking Plus, TRAK, Trends, Tribomatic, TrueBlue, TrueCoat, Tubesetter, Ultra,

UniScan, UpTime, u‐TAH, Value Plastics, Vantage, Veritec, VersaBlue, Versa‐Coat, VersaDrum, VersaPail, Versa‐Screen, Versa‐Spray, VP

Quick Fit, Walcom, Watermark, When you expect more. are registered trademarks of Nordson Corporation.

Accubar, Active Nozzle, Advanced Plasma Systems, AeroDeck, AeroWash, AltaBlue, AltaSlot, Alta Spray, AquaCure, Artiste, ATS, Auto‐Flo,

AutoScan, Axiom, Best Choice, BetterBook, Blue Series, Bravura, CanNeck, CanPro, Celero, Chameleon, Champion, Check Mate,

ClassicBlue, Classic IX, Clean Coat, Cobalt, ContourCoat, Controlled Fiberization, Control Weave, CPX, cSelect, Cyclo‐Kinetic, DispensLink,

DropCure, Dry Cure, DuraBraid, DuraCoat, e.dot+, E‐Nordson, Easy Clean, EasyOn, EasyPW, Eclipse, Equalizer, Equi=Bead, Exchange

Plus, FillEasy, Fill Sentry, Flow Coat, Fluxplus, G‐Net, G‐Site, Get Green With Blue, Gluie, Ink‐Dot, IntelliJet, iON, Iso‐Flex, iTrend, KVLP,

Lacquer Cure, Maxima, Mesa, MicroFin, MicroMax, Mikros, MiniBlue, MiniEdge, Minimeter, MonoCure, Multifil, MultiScan, Myritex, Nano,

NexJet, OmniScan, OptiMix, OptiStroke, Origin, Partnership+Plus, PatternJet, PatternPro, PCI, Pinnacle, Plasmod, PluraMix, Powder Pilot,

Powder Port, Powercure, Process Sentry, Pulse Spray, PURBlue, PURJet, PurTech, Quad Cure, Ready Coat, RediCoat, RollVIA, Royal Blue,

Select Series, Sensomatic, Shaftshield, SheetAire, Smart, Smartfil, SolidBlue, Spectral, Spectronic, SpeedKing, Spray Works, StediFlo,

Summit, Sure Brand, SureFoam, SureMix, SureSeal, Swirl Coat, TAH, Tempus, ThruWave, TinyCure, Trade Plus, Trilogy, Ultra FoamMix,

UltraMax, Ultrasaver, Ultrasmart, Universal, ValueMate, Versa, Viper, Vista, WebCure, YESTECH, 2 Rings (Design) are registeredtrademarks of Nordson Corporation.

Windows is a registered trademark of Microsoft Corporation.

Page 3: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Paul SpronckCEO

Maastricht, July 22, 2010

Nordson Benelux B.V. Bergerstraat 10 � 6226BD Maastricht � The Netherlands

Declaration of Conformity

Guidelines: 2006/42/EG

97/23/EG

Product group:

� Piston pump

Model number:

� LA 300

Part number(s):

� 7302228 (standard)

� 7302240 (wear-resistant)

International standards fulfilled:

� NEN-EN-ISO 12100-1:2003

� NEN-EN-ISO 12100-2:2003

I hereby take sole responsibility for the declaration that the above product to which this declarationrefers fulfills all of the standards and guidelines stated above.

Declared by:

− E

nglis

h −

Page 4: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05
Page 5: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Table of Contents I

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

Table of Contents

Nordson International O‐1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .http://www.nordson.com/Directory O‐1. . . . . . . . . . . . . . . . . . . . . . . . . . . .Europe O‐1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Distributors in Eastern & Southern Europe O‐1. . . . . . . . . . . . . . . . . . . . . . .Outside Europe / Hors d'Europe / Fuera de Europa O‐2. . . . . . . . . . . . .

Africa / Middle East O‐2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Asia / Australia / Latin America O‐2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Japan O‐2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .North America O‐2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

General Instructions Regarding Working with Application Materials 0‐3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Definition of Terms 0‐3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Manufacturer Information 0‐3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Liability 0‐3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Risk of Burns 0‐3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Vapors and Gases 0‐4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Substrate 0‐4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Processing Temperature 0‐4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Safety 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Safety Alert Symbols 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Responsibilities of the Equipment Owner 2. . . . . . . . . . . . . . . . . .

Safety Information 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Instructions, Requirements, and Standards 2. . . . . . . . . . . . .User Qualifications 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Applicable Industry Safety Practices 4. . . . . . . . . . . . . . . . . . . . .Intended Use of the Equipment 4. . . . . . . . . . . . . . . . . . . . . . . .Instructions and Safety Messages 4. . . . . . . . . . . . . . . . . . . . .Installation Practices 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Operating Practices 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Maintenance and Repair Practices 6. . . . . . . . . . . . . . . . . . . . .

Equipment Safety Information 7. . . . . . . . . . . . . . . . . . . . . . . . . . .Equipment Shutdown 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

General Safety Warnings and Cautions 8. . . . . . . . . . . . . . . . . . .Other Safety Precautions 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .First Aid 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 6: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Table of ContentsII

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

Description 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Intended Use 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Unintended Use - Examples - 12. . . . . . . . . . . . . . . . . . . . . . . . .Safety Instructions 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Updated Parts List 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Residual Risks 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Disposal 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Function 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Description of Components 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . .Configurations 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Wall‐mounted Pump 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Lid‐mounted Pump 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Wall‐mounted Pump with Remote Filter Assembly 19. . . . . . .Pump Mounted on Console 20. . . . . . . . . . . . . . . . . . . . . . . . . . .

Installation 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Unpacking 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Transport 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Storage 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Disposal 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Mounting 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Exhausting Adhesive Vapors 21. . . . . . . . . . . . . . . . . . . . . . . . . .Connecting 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Operation 23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Initial Startup 23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Daily Startup 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Daily Shutdown 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Maintenance 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cleaning the Pump 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Regular Pump Maintenance 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Troubleshooting 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Troubleshooting Tables 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Repair 28. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pump Disassembly and Removal 28. . . . . . . . . . . . . . . . . . . . . . . .Pump Disassembly 29. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pump Disassembly in Case of Solidified Adhesive 29. . . . . . .Removing Lid and Valve Seat 29. . . . . . . . . . . . . . . . . . . . . . . . .Disassembling the Pneumatic Assembly 30. . . . . . . . . . . . . . . .Unscrewing the Air Valve 30. . . . . . . . . . . . . . . . . . . . . . . . . . . . .Screwing Off the Filter Assembly 31. . . . . . . . . . . . . . . . . . . . . .Disassembling the Hydraulic Assembly 31. . . . . . . . . . . . . . . . .Disassembling the Pump Rod 31. . . . . . . . . . . . . . . . . . . . . . . . .

Pump Assembly 32. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Inserting the Pump Cylinder 32. . . . . . . . . . . . . . . . . . . . . . . . . . .Installing the Pump Rod in the Hydraulic Assembly 33. . . . . . .Inserting the Piston Seals in the Pneumatic Assembly 33. . . .Mounting the Pneumatic Assembly 34. . . . . . . . . . . . . . . . . . . .Mounting the Lid and Valve Seat 35. . . . . . . . . . . . . . . . . . . . . .Mounting Filter and Suction Assemblies 35. . . . . . . . . . . . . . . .

Replacing and Cleaning the Filter Cartridge 36. . . . . . . . . . . . . . .

Page 7: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Table of Contents III

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

Parts 37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Introduction 37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Updated Parts List 37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Assembly Overview 38. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Assembly, filter 40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Assembly, pneumatic 42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Assembly, hydraulic (std.) 44. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Assembly, hydraulic (w.r.) 46. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Assembly, suction hose 48. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Assembly, non return valve 49. . . . . . . . . . . . . . . . . . . . . . . . . . . . .Assembly, wall‐mount 50. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Assembly, lid‐mount 51. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pump, wall‐mount, detached filter 52. . . . . . . . . . . . . . . . . . . . . . . .Pump, console‐mount 53. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Kit, hydraulic 54. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Kit, hydraulic, small 55. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Kit, pneumatic 56. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Kit, filter 57. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Kit, fasteners 58. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Kit, fasteners, filter assembly 58. . . . . . . . . . . . . . . . . . . . . . . . . .Kit, fasteners, pneumatic assembly 58. . . . . . . . . . . . . . . . . . . .Kit, fasteners, hydraulic assembly 58. . . . . . . . . . . . . . . . . . . . .

Kit, hose, flush/return 59. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Kit, handles, lid 60. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Lubricants and Adhesives 61. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Adhesive hose 61. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Technical Data 62. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .General Information 62. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pump dimensions 63. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Permissible hose lengths for a wall‐mounted pump 64. . . . . . . . .

Page 8: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Table of ContentsIV

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

Page 9: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

O‐1Introduction

��2011 Nordson CorporationAll rights reserved

NI_EN_O‐0211

Nordson International

http://www.nordson.com/Directory

Country Phone Fax

EuropeAustria 43‐1‐707 5521 43‐1‐707 5517

Belgium 31‐13‐511 8700 31‐13‐511 3995

Czech Republic 4205‐4159 2411 4205‐4124 4971

Denmark Hot Melt 45‐43‐66 0123 45‐43‐64 1101

Finishing 45‐43‐200 300 45‐43‐430 359

Finland 358‐9‐530 8080 358‐9‐530 80850

France 33‐1‐6412 1400 33‐1‐6412 1401

Germany Erkrath 49‐211‐92050 49‐211‐254 658

Lüneburg 49‐4131‐8940 49‐4131‐894 149

Nordson UV 49‐211‐9205528 49‐211‐9252148

EFD 49‐6238 920972 49‐6238 920973

Italy 39‐02‐216684‐400 39‐02‐26926699

Netherlands 31‐13‐511 8700 31‐13‐511 3995

Norway Hot Melt 47‐23 03 6160 47‐23 68 3636

Poland 48‐22‐836 4495 48‐22‐836 7042

Portugal 351‐22‐961 9400 351‐22‐961 9409

Russia 7‐812‐718 62 63 7‐812‐718 62 63

Slovak Republic 4205‐4159 2411 4205‐4124 4971

Spain 34‐96‐313 2090 34‐96‐313 2244

Sweden 46‐40-680 1700 46‐40‐932 882

Switzerland 41‐61‐411 3838 41‐61‐411 3818

UnitedKingdom

Hot Melt 44‐1844‐26 4500 44‐1844‐21 5358

IndustrialCoatingSystems

44‐161‐498 1500 44‐161‐498 1501

Distributors in Eastern & Southern Europe

DED, Germany 49‐211‐92050 49‐211‐254 658

Page 10: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

O‐2 Introduction

��2011 Nordson CorporationAll rights reserved

NI_EN_O‐0211

Outside Europe / Hors d'Europe / Fuera de Europa

� For your nearest Nordson office outside Europe, contact the Nordson

offices below for detailed information.

� Pour toutes informations sur représentations de Nordson dans votre

pays, veuillez contacter l'un de bureaux ci‐dessous.

� Para obtener la dirección de la oficina correspondiente, por favor

diríjase a unas de las oficinas principales que siguen abajo.

Contact Nordson Phone Fax

Africa / Middle East

DED, Germany 49‐211‐92050 49‐211‐254 658

Asia / Australia / Latin America

Pacific South Division,USA

1‐440‐685‐4797 -

Japan

Japan 81‐3‐5762 2700 81‐3‐5762 2701

North America

Canada 1‐905‐475 6730 1‐905‐475 8821

USA Hot Melt 1‐770‐497 3400 1‐770‐497 3500

Finishing 1‐880‐433 9319 1‐888‐229 4580

Nordson UV 1‐440‐985 4592 1‐440‐985 4593

Page 11: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Introduction 0‐3

HMI02_EN_C-0108� 2012 Nordson Corporation

General Instructions Regarding Working withApplication Materials

Definition of TermsApplication materials can be e.g. thermoplastic hot melt materials, adhe­sives, sealants, liquid adhesives and similar application materials. They arereferred to as materials.

NOTE: The materials that may be processed with your Nordson product aredescribed in the manual under Intended Use and Unintended Use. When indoubt, please contact your Nordson representative.

Manufacturer InformationMaterials may be processed only when the manufacturer's product descrip­tions and Safety Data Sheets (MSDS) are observed.

They provide information, amongst other things, on correct processing of theproduct, transport, storage and disposal. Information regarding reactivity andpotentially hazardous decomposition products, toxic properties, flash points,etc. can also be found there.

LiabilityNordson is not be liable for danger or damage resulting from the materials.

Risk of BurnsThere is a risk of burns when handling heated materials. Work carefully andwear appropriate protective clothing/equipment.

Page 12: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Introduction0‐4

HMI02_EN_C-0108 � 2012 Nordson Corporation

Vapors and GasesEnsure that vapors and gases do not exceed the prescribed limits. If neces­sary, exhaust vapors and gases and/or provide sufficient ventilation of thework space.

SubstrateThe substrate should be free of dust, grease and moisture. The suitable ma­terial, optimum working conditions, and possible pre‐treatment of the sub­strate must be determined by testing.

Processing TemperatureWhen materials require heating, adherence to the prescribed processingtemperature is imperative to ensure the quality of the application. It may notbe exceeded! Overheating can cause material coking or cracking, resulting inmalfunctioning or unit failure.

Material should always be melted gently. Extended, unnecessary tempera­ture load should be avoided. The temperature should be reduced duringbreaks in work. The temperature in the tank should be attuned to the materialconsumption. Thus it is close to the prescribed processing temperature forhigh material consumption and lower for lower consumption.

When materials are processed cold, take into consideration the shear heatand the ambient temperature; cool if necessary.

Page 13: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Piston pump LA 300 1

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

SafetyRead this section before using the equipment. This section containsrecommendations and practices applicable to the safe installation, operation,and maintenance (hereafter referred to as “use”) of the product described inthis document (hereafter referred to as “equipment”). Additional safetyinformation, in the form of task‐specific safety alert messages, appears asappropriate throughout this document.

WARNING: Failure to follow the safety messages, recommendations, andhazard avoidance procedures provided in this document can result inpersonal injury, including death, or damage to equipment or property.

Safety Alert Symbols

The following safety alert symbol and signal words are used throughout thisdocument to alert the reader to personal safety hazards or to identifyconditions that may result in damage to equipment or property. Comply withall safety information that follows the signal word.

WARNING: Indicates a potentially hazardous situation that, if not avoided,can result in serious personal injury, including death.

CAUTION: ndicates a potentially hazardous situation that, if not avoided, canresult in minor or moderate personal injury.

CAUTION: (Used without the safety alert symbol) Indicates a potentiallyhazardous situation that, if not avoided, can result in damage to equipment orproperty.

Page 14: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

2 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

Responsibilities of the Equipment Owner

Equipment owners are responsible for managing safety information, ensuringthat all instructions and regulatory requirements for use of the equipment aremet, and for qualifying all potential users.

Safety Information

� Research and evaluate safety information from all applicable sources,

including the owner‐specific safety policy, best industry practices,governing regulations, material manufacturer's product information, andthis document.

� Make safety information available to equipment users in accordance with

governing regulations. Contact the authority having jurisdiction forinformation.

� Maintain safety information, including the safety labels affixed to the

equipment, in readable condition.

Instructions, Requirements, and Standards

� Ensure that the equipment is used in accordance with the information

provided in this document, governing codes and regulations, and bestindustry practices.

� If applicable, receive approval from your facility's engineering or safety

department, or other similar function within your organization, beforeinstalling or operating the equipment for the first time.

� Provide appropriate emergency and first aid equipment.

� Conduct safety inspections to ensure required practices are being

followed.

� Re‐evaluate safety practices and procedures whenever changes are

made to the process or equipment.

Page 15: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Piston pump LA 300 3

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

User Qualifications

Equipment owners are responsible for ensuring that users:

� Receive safety training appropriate to their job function as directed by

governing regulations and best industry practices

� Are familiar with the equipment owner's safety and accident

prevention policies and procedures

� Receive, equipment‐ and task‐specific training from another qualified

individual

NOTE: Nordson can provide equipment‐specific installation,operation, and maintenance training. Contact your Nordsonrepresentative for information

� Possess industry‐ and trade‐specific skills and a level of experience

appropriate to their job function

� Are physically capable of performing their job function and are not

under the influence of any substance that degrades their mentalcapacity or physical capabilities

Page 16: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

4 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

Applicable Industry Safety Practices

The following safety practices apply to the use of the equipment in themanner described in this document. The information provided here is notmeant to include all possible safety practices, but represents the best safetypractices for equipment of similar hazard potential used in similar industries.

Intended Use of the Equipment

� Use the equipment only for the purposes described and within the limits

specified in this document.

� Do not modify the equipment.

� Do not use incompatible materials or unapproved auxiliary devices.

Contact your Nordson representative if you have any questions onmaterial compatibility or the use of non‐standard auxiliary devices.

Instructions and Safety Messages

� Read and follow the instructions provided in this document and other

referenced documents.

� Familiarize yourself with the location and meaning of the safety warning

labels and tags affixed to the equipment. Refer to Safety Labels andTags (if available) at the end of this section.

� If you are unsure of how to use the equipment, contact your Nordson

representative for assistance.

Page 17: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Piston pump LA 300 5

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

Installation Practices

� Install the equipment in accordance with the instructions provided in this

document and in the documentation provided with auxiliary devices.

� Ensure that the equipment is rated for the environment in which it will be

used and that the processing characteristics of the material will not createa hazardous environment. Refer to the Material Safety Data Sheet(MSDS) for the material.

� If the required installation configuration does not match the installation

instructions, contact your Nordson representative for assistance.

� Position the equipment for safe operation. Observe the requirements for

clearance between the equipment and other objects.

� Install lockable power disconnects to isolate the equipment and all

independently powered auxiliary devices from their power sources.

� Properly ground all equipment. Contact your local building code

enforcement agency for specific requirements.

� Ensure that fuses of the correct type and rating are installed in fused

equipment.

� Contact the authority having jurisdiction to determine the requirement for

installation permits or inspections.

Operating Practices

� Familiarize yourself with the location and operation of all safety devices

and indicators.

� Confirm that the equipment, including all safety devices (guards,

interlocks, etc.), is in good working order and that the requiredenvironmental conditions exist.

� Use the personal protective equipment (PPE) specified for each task.

Refer to Equipment Safety Information or the material manufacturer'sinstructions and MSDS for PPE requirements.

� Do not use equipment that is malfunctioning or shows signs of a potential

malfunction.

Page 18: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

6 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

Maintenance and Repair Practices

� Perform scheduled maintenance activities at the intervals described in

this document.

� Relieve system hydraulic and pneumatic pressure before servicing the

equipment.

� De‐energize the equipment and all auxiliary devices before servicing the

equipment.

� Use only new or factory‐authorized refurbished replacement parts.

� Read and comply with the manufacturer's instructions and the MSDS

supplied with equipment cleaning compounds.

NOTE: MSDSs for cleaning compounds that are sold by Nordson areavailable at www.nordson.com or by calling your Nordson representative.

� Confirm the correct operation of all safety devices before placing the

equipment back into operation.

� Dispose of waste cleaning compounds and residual process materials

according to governing regulations. Refer to the applicable MSDS orcontact the authority having jurisdiction for information.

� Keep equipment safety warning labels clean. Replace worn or damaged

labels.

Page 19: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Piston pump LA 300 7

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

Equipment Safety Information

This equipment safety information is applicable to the following types ofNordson equipment:

� hot melt and cold adhesive application equipment and all related

accessories

� pattern controllers, timers, detection and verification systems, and all

other optional process control devices

Equipment Shutdown

To safely complete many of the procedures described in this document, theequipment must first be shut down. The level of shut down required varies bythe type of equipment in use and the procedure being completed. If required,shut down instructions are specified at the start of the procedure. The levelsof shut down are:

Relieving System Hydraulic Pressure

Completely relieve system hydraulic pressure before breaking any hydraulicconnection or seal. Refer to the melter‐specific product manual forinstructions on relieving system hydraulic pressure.

De‐energizing the System

Isolate the system (melter, hoses, guns, and optional devices) from all powersources before accessing any unprotected high‐voltage wiring or connectionpoint.

1. Turn off the equipment and all auxiliary devices connected to theequipment (system).

2. To prevent the equipment from being accidentally energized, lock andtag the disconnect switch(es) or circuit breaker(s) that provide inputelectrical power to the equipment and optional devices.

NOTE: Government regulations and industry standards dictate specificrequirements for the isolation of hazardous energy sources. Refer to theappropriate regulation or standard.

Disabling the Guns

All electrical or mechanical devices that provide an activation signal to theguns, gun solenoid valve(s), or the melter pump must be disabled beforework can be performed on or around a gun that is connected to a pressurizedsystem.

1. Turn off or disconnect the gun triggering device (pattern controller, timer,PLC, etc.).

2. Disconnect the input signal wiring to the gun solenoid valve(s).

3. Reduce the air pressure to the gun solenoid valve(s) to zero; then relievethe residual air pressure between the regulator and the gun.

Page 20: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

8 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

General Safety Warnings and Cautions

Table 1‐1 contains the general safety warnings and cautions that apply toNordson hot melt and cold adhesive equipment. Review the table andcarefully read all of the warnings or cautions that apply to the type ofequipment described in this manual.

Equipment types are designated in Table 1‐1 as follows:

HM = Hot melt (melters, hoses, guns, etc.)

PC = Process control

CA = Cold adhesive (dispensing pumps, pressurized container, andguns)

Tabelle 1 General Safety Warnings and Cautions

EquipmentType Warning or Caution

HM

WARNING: Hazardous vapors! Before processing any polyurethanereactive (PUR) hot melt or solvent‐based material through a compatibleNordson melter, read and comply with the material's MSDS. Ensurethat the material's processing temperature and flashpoints will not beexceeded and that all requirements for safe handling, ventilation, firstaid, and personal protective equipment are met. Failure to comply withMSDS requirements can cause personal injury, including death.

HM

WARNING: Reactive material! Never clean any aluminum componentor flush Nordson equipment with halogenated hydrocarbon fluids.Nordson melters and guns contain aluminum components that mayreact violently with halogenated hydrocarbons. The use ofhalogenated hydrocarbon compounds in Nordson equipment cancause personal injury, including death.

HM, CA

WARNING: System pressurized! Relieve system hydraulic pressurebefore breaking any hydraulic connection or seal. Failure to relieve thesystem hydraulic pressure can result in the uncontrolled release of hotmelt or cold adhesive, causing personal injury.

HM

WARNING: Molten material! Wear eye or face protection, clothing thatprotects exposed skin, and heat‐protective gloves when servicingequipment that contains molten hot melt. Even when solidified, hotmelt can still cause burns. Failure to wear appropriate personalprotective equipment can result in personal injury.

Continued...

Page 21: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Piston pump LA 300 9

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

General Safety Warnings and Cautions (contd)

Table 1‐1 General Safety Warnings and Cautions (contd)

EquipmentType Warning or Caution

HM, PC

WARNING: Equipment starts automatically! Remote triggeringdevices are used to control automatic hot melt guns. Before workingon or near an operating gun, disable the gun's triggering device andremove the air supply to the gun's solenoid valve(s). Failure to disablethe gun's triggering device and remove the supply of air to the solenoidvalve(s) can result in personal injury.

HM, CA, PC

WARNING: Risk of electrocution! Even when switched off andelectrically isolated at the disconnect switch or circuit breaker, theequipment may still be connected to energized auxiliary devices.De‐energize and electrically isolate all auxiliary devices beforeservicing the equipment. Failure to properly isolate electrical power toauxiliary equipment before servicing the equipment can result inpersonal injury, including death.

HM, CA, PC

WARNING: Risk of fire or explosion! Nordson adhesive equipment isnot rated for use in explosive environments and should not be usedwith solvent‐based adhesives that can create an explosive atmospherewhen processed. Refer to the MSDS for the adhesive to determine itsprocessing characteristics and limitations. The use of incompatiblesolvent‐based adhesives or the improper processing of solvent‐basedadhesives can result in personal injury, including death.

HM, CA, PC

WARNING: Allow only personnel with appropriate training andexperience to operate or service the equipment. The use of untrainedor inexperienced personnel to operate or service the equipment canresult in injury, including death, to themselves and others and candamage the equipment.

Continued...

Page 22: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

10 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

EquipmentType Warning or Caution

HM

CAUTION: Hot surfaces! Avoid contact with the hot metal surfaces ofguns, hoses, and certain components of the melter. If contact can notbe avoided, wear heat‐protective gloves and clothing when workingaround heated equipment. Failure to avoid contact with hot metalsurfaces can result in personal injury.

HM

CAUTION: Some Nordson melters are specifically designed toprocess polyurethane reactive (PUR) hot melt. Attempting to processPUR in equipment not specifically designed for this purpose candamage the equipment and cause premature reaction of the hot melt.If you are unsure of the equipment's ability to process PUR, contactyour Nordson representative for assistance.

HM, CA

CAUTION: Before using any cleaning or flushing compound on or inthe equipment, read and comply with the manufacturer's instructionsand the MSDS supplied with the compound. Some cleaningcompounds can react unpredictably with hot melt or cold adhesive,resulting in damage to the equipment.

HM

CAUTION: Nordson hot melt equipment is factory tested with NordsonType R fluid that contains polyester adipate plasticizer. Certain hotmelt materials can react with Type R fluid and form a solid gum thatcan clog the equipment. Before using the equipment, confirm that thehot melt is compatible with Type R fluid.

Page 23: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Piston pump LA 300 11

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

Other Safety Precautions� Do not use an open flame to heat hot melt system components.

� Check high pressure hoses daily for signs of excessive wear, damage, or

leaks.

� Never point a dispensing handgun at yourself or others.

� Suspend dispensing handguns by their proper suspension point.

First Aid

If molten hot melt comes in contact with your skin:

1. Do NOT attempt to remove the molten hot melt from your skin.

2. Immediately soak the affected area in clean, cold water until the hot melthas cooled.

3. Do NOT attempt to remove the solidified hot melt from your skin.

4. In case of severe burns, treat for shock.

5. Seek expert medical attention immediately. Give the MSDS for the hotmelt to the medical personnel providing treatment.

Page 24: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

12 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

Description

Intended Use

The LA 300 series piston pumps - subsequently also referred to as pumps -have been specially designed for the application of water‐based adhesives.

Any other use is considered to be unintended. Nordson will not be liable forpersonal injury and/or property damage resulting from unintended use.

Intended use includes the observance of Nordson safety instructions.Nordson recommends obtaining detailed information on the materials to beused.

The product described here is to be operated, serviced and maintained onlyby persons who are familiar with the product and who have been informed ofthe potential hazards.

The respective rules for prevention of accidents as well as any othercommonly recognized safety regulations and industrial health regulations areto be observed.

The manufacturer is by no means liable for any damage resulting fromunauthorized modifications.

Unintended Use - Examples -

The pump may not be used under the following conditions:

� In defective condition

� In a potentially explosive atmosphere

� With opened covers

� In surroundings which do not correspond to the unit's Degree of

Protection

� With unauthorized modifications

� When unsuitable liquid adhesives are used

� When the values stated under Technical Data are not complied with.

The pump may not be used to process the following materials:

� Explosive and flammable materials

� Materials sensitive to pressure

� Latex materials

� Food products.

Page 25: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Piston pump LA 300 13

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

Safety Instructions

Prior to installation and startup of the system, it is essential to read and followthe safety instructions!

The general safety instructions are enclosed as an annex to thedocumentation folder or they are a section of this manual.

The specific safety instructions are part of this manual.

Updated Parts List

Please observe that your Nordson equipment may differ slightly from thedescription or some information details in the manual. Refer to the updatedParts List which is packed with your equipment.

When in doubt, please contact Nordson.

Residual Risks

In the design of the unit, every measure was taken to protect personnel frompotential danger. However, some residual risks cannot be avoided.Personnel should be aware of the following:

� System components which are under pressure.

� Possible electrical charges in components even after switching the

system off.

� Liquid adhesive vapors.

� Hydraulically or pneumatically driven system components

Disposal

Devices and materials used during operation and maintenance must bedisposed of according to the applicable laws.

Page 26: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

14 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

Function

The following figure illustrates the basic method of operation of a pistonpump within a complete system.

Adhesive is to be applied to a substrate (7). The transport belts (8) conveythe substrates. When the leading edge of a substrate reaches the photo cell(10), the beam of light sent is reflected and the program is started. Thecontroller compiles all the data according to the speed of the productionmachine. The encoder (4) is mechanically connected to the transportequipment via a gear and supplies one pulse per mm. The control unitevaluates all the data and establishes the point at which the liquid adhesiveguns (5) must be activated.

The piston pump (12) is connected to the compressed air supply (1). Itoperates continuously and pumps the liquid adhesive from the adhesivereservoir (11) to the liquid adhesive guns.

A current between 0‐20 mA is supplied from the control unit (3) to theproportional pressure control valve (2). The strength of the current isdependent on the speed of the production machine. The strength of thecurrent determines how far the proportional pressure control valve should beopened and the pressure regulator (9) opens accordingly. The adhesiveflows to the liquid adhesive guns and is applied to the substrate. The length

of the application is defined by the controller’s program.

Page 27: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Piston pump LA 300 15

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

Electrical components

Compressed air

Adhesive

1

2

3

4

5

6

7

8

9

10

12

11

Fig. 1 Principle drawing

1 Compressed air connection

2 Proportional valve

3 Control unit

4 Encoder

5 Liquid adhesive gun

6 Adhesive pattern

7 Substrate

8 Conveyor belt

9 Adhesive pressure regulator

10 Photo cell

11 Adhesive container

12 Piston pump LA 300

Page 28: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

16 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

Description of Components

The pump is comprised of various components.

2

5

1

7

6

4

3

Fig. 2 Main components

1 Pneumatic assembly (air motor)

2 Air valve

3 Maintenance unit with air pressureregulator

4 Hydraulic assembly

5 Wall mounting bracket

6 Suction assembly with filter

7 Filter assembly with pressure reliefvalve

All parts which come into contact with moisture are made of stainless steel orspecial plastic to reduce corrosion.

NOTE: The pump described in this section relates to a standard pumpexcept where specific reference is made to others. Individual applicationsrequire individual solutions. In such cases, please contact Nordson.

Page 29: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Piston pump LA 300 17

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

Configurations

Wall‐mounted Pump

2

13

Fig. 3 Wall‐mounted pump

1 Lid for hose(315 or 400 mm diameter)

2 Reserved hole (level monitoring)

3 Reserved hole (flush/return hose)

Page 30: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

18 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

Configurations (contd.)

Lid‐mounted Pump

3

1

2

Fig. 4 Lid‐mounted pump

1 Pressure regulator (380 series) 2 Reserved holes (level monitoring) 3 Lid for pump (315 or 400 mm diameter)

Page 31: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Piston pump LA 300 19

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

Wall‐mounted Pump with Remote Filter Assembly

2

1

Fig. 5 Wall‐mounted pump with remote filter assembly

1 Extension hose(1.5 to 9.0 m)

2 Filter unit

NOTE: The extension hose can be connected to either side of the pump.

Page 32: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

20 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

Configurations (contd.)

Pump Mounted on Console

21 3

76

54

98

Fig. 6 Pump mounted on console

1 Manifold (4- or 8-fold)

2 Controller (timer)

3 Pressure regulator (380 series)

4 Level monitoring

5 Run‐up (single or double)

6 Pump, LA 300

7 Touch screen

8 System console (ASC)

9 Reserved hole(flush/return hose kit)

Page 33: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Piston pump LA 300 21

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

InstallationWARNING: Allow only qualified personnel to perform the following tasks.Observe and follow the safety instructions in this document and all otherrelated documentation.

UnpackingThe pump is fully assembled at the factory. Unpack the equipment carefullyto prevent damage. After unpacking the pump, check for signs of damagewhich may have occurred during transport. Check that all screws are tight.Notify Nordson in the case of any damage.

TransportThe pump is a high precision, valuable part. Handle very carefully!

StorageDo not store outside! Protect from humidity and dust.

DisposalWhen your Nordson product has exhausted its purpose and/or is no longerneeded, dispose of it properly according to local regulations.

MountingWhen installing the pump, the following points should be observed in order toavoid unnecessary work later.

� Protect from humidity, vibrations, dust and drafts.

� Ensure access to parts relevant for maintenance and operation.

� During assembly, ensure that the distance between the piston pump or

proportional pressure control valve and the regulator is as small aspossible in order to achieve optimum operation.

CAUTION: Ensure that the pump is installed vertically on the wall.

� When installing the unit, ensure that air and liquid adhesive hoses cannot

be bent, pinched, torn off or otherwise damaged.

Exhausting Adhesive Vapors

Ensure that adhesive vapors do not exceed the prescribed limits. Exhaustadhesive vapors when necessary. Provide sufficient ventilation of thelocation where the unit is installed.

Page 34: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

22 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

Connecting

The connections used are described in the following.

1. Remove the plastic cap from the air inlet (1) and connect the pump to thecompressed air supply.

2. Insert the adhesive suction hose (3) in the adhesive container.

3. Remove the plastic cap from the outlet of the pressure relief valve (4).Connect a flush/return hose to the outlet and feed the hose back to theadhesive container.

4. Remove the plastic cap from the adhesive outlet of the filter (5) andconnect the adhesive outlet to the adhesive pressure regulator.

1

5

3

4

2

Fig. 7 Pump in installation position

1 Air inlet

2 Oil filling hole

3 Adhesive suction hose

4 Pressure relief valve

5 Adhesive outlets

Page 35: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Piston pump LA 300 23

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

Operation

Initial Startup

Check that all the connections have been made properly.

1. Remove the plug from the oil filling hole (2, Fig. 7) incl. label.

NOTE: Do not insert plug again later.

2. Fill up fully with oil using the oil bottle supplied (Refer to Oil in the SectionParts):

CAUTION: If the equipment is operated without sufficient lubrication, thepiston rings will become damaged and have to be replaced.

3. Shut off the compressed air supply on the piston pump (12, Fig. 1).

4. Open the piston pump compressed air regulator slightly to supply thesystem with compressed air slowly.

5. Regulate the compressed air on the piston pump so that the adhesivepressure at the pressure regulator inlet is always greater than therequired adhesive pressure at the regulator outlet (working pressure ofthe adhesive).

6. NOTE: Activate (spray) all the liquid adhesive guns connected to thepressure regulator until liquid adhesive flows smoothly and without anyair bubbles.

NOTE: To vent the system more efficiently, remove the nozzles or nozzleplates first of all and replace them, as necessary, later.

7. Position the substrate under the liquid adhesive gun, carry out a testadhesive application and check the adhesive bead. If the bead is too thin,increase the pressure on the piston pump.

CAUTION: Do not exceed the required pressure for feeding the liquid

adhesive. Excessive pressure can change the adhesive’s properties.

8. Check all connections for any leakage, tighten as necessary.

CAUTION: If the piston pump is connected in series with a filter, theadhesive pressure is not fully relieved by simply shutting off the compressedair supply, depending on the filter implemented (with ball valve). Ensure thatthe pressure relief valve of the filter is open in order to relieve the pressure ofthe adhesive. Otherwise, adhesive may escape unexpectedly.

Page 36: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

24 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

Operation (contd.)

Daily Startup

1. Check the quantity of adhesive in the adhesive container.

2. Activate the compressed air supply to the piston pump.

Daily Shutdown

1. Block the compressed air supply to the piston pump.

Page 37: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Piston pump LA 300 25

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

MaintenanceWARNING: Allow only qualified personnel to perform the following tasks.Observe and follow the safety instructions in this document and all otherrelated documentation.

The pump is maintenance‐friendly and, in general, maintenance-free. Undernormal conditions, all the components have a long service life.

WARNING: Stop the compressed air and adhesive supplies!

WARNING: When possible, always wear protective gloves when carryingout the work.

Always observe the following basic points:

� It is essential to ensure that the material to be applied is in a clean,

filtered condition. The control air should also be clean and, under certaincircumstances, lightly oiled when fed to the equipment.

� Individual operating conditions and different application material require a

corresponding minimum effort for maintenance.

� Do not use metallic, sharp-edged tools to clean the outside of the

equipment, e.g. nozzle tips, only use soft brushes.

� When carrying out repair and maintenance work, keep the working space

as well as the pump to be repaired as clean as possible.

� Pumps and pressure regulators which are soiled should be thoroughly

flushed through when the opportunity occurs. This is possible particularlywhen parts need to be replaced.

� The pump should not remain installed for any important maintenance

work, but be removed.

� Stop the pressure and material supply lines beforehand.

Cleaning the Pump

It is not normally necessary to clean the pump.

Regular Pump Maintenance

WARNING: The oil level in the pump>’s chamber must be checked every

three months; refill with oil, if necessary.

Page 38: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

26 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

TroubleshootingWARNING: Allow only qualified personnel to perform the following tasks.Observe and follow the safety instructions in this document and all otherrelated documentation.

WARNING: Troubleshooting activities may sometimes have to be carriedout when the system is energized. Observe all safety instructions andregulations concerning energized unit components (active parts). Failure toobserve may result in an electric shock.

Troubleshooting Tables

The troubleshooting tables serve as an orientation for qualified personnel.They cannot, however, replace targeted fault location with the help of wiringdiagrams and measuring instruments. They also do not include all possibleproblems, only those which most typically occur.

Problem Possible Cause Corrective Action

Pump does not feed Adhesive container is empty Refill or change the container

Compressed air supply isdisrupted

Check the air feed to the piston pump and atthe compressed air source

Air valve defective Press the reset button on the bottom and topof the air valve. If the pump still does not feed,replace the air valve

Pneumatic assembly piston sealdefect or worn out

Replace seal

Pump runs too fast Compressed air supply topneumatic assembly too high

Reduce the compressed air supply!

Damaged hose connection(adhesive leaks)

Replace connection

Adhesive container is empty Refill or change the container

Piston seal or piston in thehydraulic assembly (incontainer) defect or worn out

Replace piston seal or piston

Pump does notoperate properly

Adhesive residue inside thepump

Flush pump with water; disassemble andclean pump, if necessary

Piston seal defect Check oil level in plunger room

Replace piston seal

Page 39: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Piston pump LA 300 27

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

Adhesive or oilescapes from the oilfilling hole

Adhesive residue inside thepump

Flush pump with water; disassemble andclean pump, if necessary

Plunger seal defect Check oil level in plunger room

Replacing Piston Seal

Pump only runs forone cycle

Hydraulic assembly feed valvedoes not close (soiled)

Run the pump at varying speeds to loosen thedirt and clean the ball valves

Adhesive container is empty Refill or change the container

Pump runs but thereis no pressurebuild‐up

Adhesive viscosity too high Use an adhesive with a lower viscosity; if indoubt, contact Nordson or the adhesivemanufacturer

Piston seal or piston in thehydraulic assembly defect orworn out

Replace piston seal or piston

Adhesive applicationguns blocked

Adhesive filter slightly soiled ordefective

Check filter; replace, if necessary

Page 40: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

28 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

RepairWARNING: Allow only qualified personnel to perform the following tasks.Observe and follow the safety instructions in this document and all otherrelated documentation.

WARNING: System pressurized. Relieve system pressure. Failure to do socan result in serious injury.

The pump is comprised of the following components which are assembled tothe wall‐mounting bracket:

� Adhesive filter unit

� Pneumatic assembly with air valve

� Hydraulic assembly

� Suction assembly

In order to disassemble the pneumatic or hydraulic assembly, the entirepump must be disassembled or removed beforehand.

NOTE: In order to replace the adhesive filter and the air valve, or to cleanthe filter cartridge of the adhesive filter, the pump can remain assembled.

Pump Disassembly and Removal

WARNING: Since the filter operates in conjunction with a ball valve, theadhesive pressure is not fully relieved by simply shutting off the compressedair supply. Ensure that the pressure relief valve is fully open in order torelieve the pressure of the adhesive. Otherwise, pressurized adhesive mayescape unexpectedly.

1. Set the compressed air supply on the air pressure regulator to '0' andopen the quick connector of the compressed air hose.

2. Disconnect the adhesive hoses from the adhesive filter.

3. Remove the complete pump together with the suction assembly from thewall.

NOTE: The oil chamber contains oil. Always drain the oil prior todisassembling the pump.

4. Set the pump down on the workbench carefully.

Page 41: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

4

3

1

5

2

6

Piston pump LA 300 29

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

Pump Disassembly

Pump Disassembly in Case of Solidified Adhesive

Do not disassemble the pump if it has become stuck with solidified adhesive!It is highly likely this would damage sensitive components.

NOTE: The oil chamber contains oil. Always drain the oil prior todisassembling the pump.

We recommend immersing the pump, without pneumatic assembly, in warmwater for one day to soften the glue. Repeat the process several times, ifnecessary. If the pump still cannot be disassembled, return it to us for repair.

CAUTION: Never use metallic or sharp‐edged tools.

Removing Lid and Valve Seat

1. Unscrew the hose connection (4) from the valve seat (3) and remove theentire suction assembly (5).

2. Unscrew the valve seat (3) from the hydraulic assembly (2).

3. Remove the lid (1) from the pneumatic assembly (6).

Fig. 8

Page 42: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

1

30 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

Pump Disassembly (contd.)

Disassembling the Pneumatic Assembly

1. Remove the three Allen head screws (1).

2. Move the pneumatic assembly (5) and hydraulic assembly (2) away fromeach other.

3. Place a wrench (7) on the pump rod (3) of the hydraulic assembly.

4. Place a socket wrench (6) on the nut fixing the piston and remove the nut.Then remove the tools and pneumatic assembly.

5. Remove the retainer clip (21, Fig. 27) from between the pump rod of thepneumatic assembly and pump rod (4) of the hydraulic assembly andscrew the rods away from each other.

6. Remove the piston carefully from the pneumatic assembly.

1 2

7 6

3 4 5

Fig. 9

Unscrewing the Air Valve

1. Remove the two screws (1) and take off the air valve with gasket.

Fig. 10

Page 43: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

3

1

2

4

12

3

1

4

5

2

3

6

1

2

3

Piston pump LA 300 31

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

Screwing Off the Filter Assembly

1. Remove the four Allen head screws (3).

2. Remove the entire filter assembly (1) and adapter (2).

NOTE: Never unscrew the seat of the pressure relief valve (16, Fig. 25).

Fig. 11

Disassembling the Hydraulic Assembly

1. Remove the cover (1) from the hydraulic assembly.

2. Press the pump rod (2) downwards out of the hydraulic assembly.

CAUTION: Always press the pump rod out downwards to prevent damagingany seals.

3. Unscrew the oil chamber (4).

NOTE: Insert a suitable tool in the oil chamber’s filling opening (3) to operate

as a lever.

Fig. 12

4. Remove the various piston rings (1) and the compression spring (2)carefully.

5. Remove the two socket set screws (8, Fig. 27) located under thewall‐mounting bracket (5) in the radial manifold (4).

6. Press the pump cylinder (3) upwards out of the radial manifold.

7. Remove the snap ring (6) from the pump cylinder.

NOTE: If only the piston rings and pump rods are changed, Steps 5 ‐ 7 arenot applicable.

Fig. 13

Disassembling the Pump Rod

1. Apply a wrench to hold the pump rod (1).

2. Unscrew the valve seat (3) from the pump rod using an Allen key.

3. Remove the valve (2).

CAUTION: Do not damage the surface of the pump rod. Keep the pump rodin a safe place after it has been removed.

Fig. 14

Page 44: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

32 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

Pump Assembly

NOTE: If old components are to be reused when the pump is reassembled,clean all the elements thoroughly with water. There must be no residue lefton them.

CAUTION: Clear all elements of residual particles. Otherwise, permanentdamage could result, e.g. leaks.

Inserting the Pump Cylinder

1. If it has not already been done, remove the hexagon head screw plug (7,Fig. 27) from the radial manifold.

NOTE: If only the piston rings and rods have been changed, continue withStep 4.

CAUTION: Always slide the pump cylinder in the radial manifold from thebottom to prevent damaging the seals.

2. Slide the pump cylinder in the radial manifold from the bottom to the top.

3. Mount the snap ring and insert the two socket set screws (8, Fig. 27). Donot tighten the socket set screws tight.

4. Turn the pump cylinder so that the bores in the pump cylinder matchthose in the radial manifold.

5. Install the compression spring from the top and use a round piece ofwood or plastic rod to press it together as far as possible and then useone or two screwdrivers to fix it in this pretensioned state.

6. Insert the piston rings according to the sequence illustrated.

Fig. 15

Page 45: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

3

1

2

3

1

2

Piston pump LA 300 33

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

7. Insert the three Allen head screws (3) with lock washers in the oilchamber (1).

8. Mount the oil chamber and screw tight clockwise.

9. Then remove the two screwdrivers.

10. Turn the entire pump cylinder until the oil filling opening (2) faces thefront, as illustrated.

11. Tighten the socket set screws.

Fig. 16

Installing the Pump Rod in the Hydraulic Assembly

NOTE: Before mounting the cover, ensure that the scraper (3, Fig. 27 ) andwear ring (2, Fig. 27) have been installed in the lid. The wear ring is fitted atthe top of the lid.

1. Always mount the lid of the hydraulic assembly first.

CAUTION: To prevent damage to the various piston rings, always insert thepump rod (1) from the top.

2. Insert the pump rod.

3. Use a wrench to hold the pump rod still and use an Allen key to screw thevalve (2) and valve seat (3) securely to the rod.

4. Then press the pump rod upwards out of the hydraulic assembly as far aspossible.

Inserting the Piston Seals in the Pneumatic Assembly

� Never use metallic or sharp‐edged tools to install O‐rings.

� Install the piston seals on the two pistons so that the opening of the

V‐shaped seal on the upper piston faces down and faces up on the lowerpiston. Also refer to Fig. 26.

Fig. 17

Fig. 18

CAUTION: The seal should be installed without implementing anysharp-edged tools.

Page 46: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

34 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

Pump Assembly (contd.)

Mounting the Pneumatic Assembly

1. Screw the piston rod (3) of the pneumatic assembly in the piston rod (1)of the hydraulic assembly.

2. Align the holes and install the retaining clip (2).

2 31

Fig. 19

3. Then pull the piston rod (3) upwards out of the hydraulic assembly (2) asfar as possible.

4. Slide the air cylinder (5) over the piston rod (4).

5. Insert the upper piston (6) in the air cylinder and slide onto the piston rod.

6. Place a wrench (8) on the piston rod (3) of the hydraulic assembly.

7. Mount the nut on the upper piston and tighten using a wrench (7).

8. Remove the tools and slide the hydraulic and pneumatic assembliestogether.

9. Screw the two assemblies to each other with the screws (1).

10. Mount the lid on the pneumatic assembly.

1 2

8 7

3 4 5 6

Fig. 20

Page 47: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

1

2

1

4

2

3

Piston pump LA 300 35

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

Mounting the Lid and Valve Seat

1. Mount the lid (1) on the pneumatic assembly.

2. Screw the valve seat (2) in the hydraulic assembly.

Fig. 21

Mounting Filter and Suction Assemblies

1. Screw the filter assembly (4) with the adapter (3) securely to the radialmanifold.

2. Screw the complete suction assembly (2) with hose connection (1) intothe valve seat.

WARNING: Never put the pump into operation without having filled with oilbeforehand. Refer to Initial Startup.

Fig. 22

Page 48: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

1

36 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

Replacing and Cleaning the Filter Cartridge

1. Unscrew the filter assembly cover (1).

2. Remove the filter cartridge with ball.

3. Remove the ball from the filter cartridge and clean or replace it.

4. Insert the filter cartridge with ball in the filter housing.

5. Clean the thread of the filter housing and cover, and apply a thin coat ofsilicone paste.

6. Screw the cover on the filter housing. When screwed on correctly, a gapof approx. 1 to 2 mm must be visible between the cover and filterhousing.

Fig. 23 �

Page 49: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Piston pump LA 300 37

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

Parts

Introduction

The parts in this section are divided into the following columns:

Item — Identifies the parts shown, available from Nordson.

Part — Nordson spare part number for each available part shown in the

illustration. A series of hyphens (‐ ‐ ‐ ‐ ‐) in the Parts column means thatthe part cannot be ordered separately.

Description — This column contains the name of the part and, when

appropriate, the dimensions and other properties. The dots in theDescription column illustrate the relationship between assemblies,subassemblies and individual parts.

Quantity— The quantity required per unit, assembly or subassembly.

The abbreviation AR (as required) is used to designate that items arestated in drum sizes or that the quantity required per assembly is a factorof the product version or the model.

NOTE: The texts are available only in English.

Updated Parts List

Please observe that your unit may differ slightly from the description or fromcertain details in the manual. Refer to the updated Parts List which is packedwith your equipment.

Page 50: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

38 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

Assembly Overview

5

1

3

2

6

4

Fig. 24 Assembly Overview

Page 51: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Piston pump LA 300 39

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

Item Part Description Qty Remarks

‐ 7302228 Pump, piston, LA300, standard

1 7303360 Assembly, pneumatic, pump, LA300 1 See Assembly, pneumatic

2 7302234 Assembly, hydraulic (std), pump, LA300 1 See Assembly, hydraulic(std.)

3 7301100 Assembly, filter, pump, LA300 1 See Assembly, filter

4 7303800 Assembly, suction hose, 5/8”, pump, LA300 1 See Assembly, suctionhose

5 ‐ Name plate, pump LA300, standard 1

6 7302237 Fitting, 90°, male ‐ female, 1/2”, SS 1

Item Part Description Qty Remarks

‐ 7302240 Pump, piston, LA300, wear resistant

1 7303360 Assembly, pneumatic, pump, LA300 1 See Assembly, pneumatic

2 7303133 Assembly, hydraulic (w.r.), pump, LA300 1 See Assembly, hydraulic(w.r.)

3 7301100 Assembly, filter, pump, LA300 1 See Assembly, filter

4 7303800 Assembly, suction hose, 5/8”, pump, LA300 1 See Assembly, suctionhose

5 ‐ Name plate, pump LA300, wear resistant 1

6 7302237 Fitting, 90°, male ‐ female, 1/2”, SS 1

Page 52: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

40 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

Assembly, filter

14

4

7 6 6 2 1

5

1

1514

10

9

8

3

13 7

12

11

16

Fig. 25 Assembly, filter

Page 53: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Piston pump LA 300 41

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

Item Part Description Qty Remarks

‐ 7301100 Assembly, filter, pump, LA300

1 7300213 Assembly, filter, housing, pump, LA300 1

7300203 Cover, filter, LA piston pump 1

2 ‐ Seal, interior, filter lid, LA piston pump 1 See Kit, filter

3 ‐ O‐ring, 47.35 x 1.78, Aflas 1 See Kit, filter

4 311208 Ball, 20 mm 1

5 ‐ Filter, cartridge, 50 mesh 1 See Kit, filter

6 377590 Fitting, nipple, G1/4M x 1/2‐20 UNF, SS 3

7 311551 Cap, plastic, 1/2”‐20 2

8 311639 Cap, blank, 1/2”‐20 UNF, SS 2

9 7300212 Assembly, handle, pressure relieve valve 1

10 ‐ Screw, allenhead, M5 x 90, DIN912, A2 4 See Kit, fasteners, filter assy

11 ‐ O‐Ring, 4.47 x 1.78, Aflas 1 See Kit, filter

12 ‐ Washer, spring, M5, DIN7980, A2 4 See Kit, fasteners,filter assy

13 372570 Fitting, nipple, 1/8 BSP ‐ 1/2‐20 UNF, SS 1

14 ‐ O‐Ring, 21.9 x 2.62, Aflas 2 See Kit, filter

15 7300209 Connector, filter‐pump, LA piston pump 1

16 ‐ Seat, pressure relief valve, pump, LA300 ‐

Page 54: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

42 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

Assembly, pneumatic

24

4

17

1 2 3

5

6

7

8

9

11

10

12

13

7

14

15

16

18

19

20

27

25 292623

28

22

21

Fig. 26 Assembly, pneumatic

Page 55: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Piston pump LA 300 43

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

Item Part Description Qty Remarks

‐ 7303360 Assembly, pneumatic, pump, LA300

1 ‐ Screw, allenhead, M4 x 12, DIN912, A2 2 See Kit, fasteners,pneumatic assy

2 ‐ Washer, spring, M4, DIN7980, A2 2 See Kit, fasteners,pneumatic assy

3 7300186 Cover, cylinder, air motor, pump, LA300 1

4 ‐ Nut, hex, M8, DIN985, galZn 1 See Kit, fasteners,pneumatic assy

5 7300192 Piston upper, airmotor, ø 70 mm, pump, LA300 1

6 ‐ O‐ring 8.5 x 2, Viton-B 1 See Kit, pneumatic

7 ‐ Seal, piston, ø 70 mm, air motor, pump, LA300 2 See Kit, pneumatic

8 ‐ Screw, allenhead, M4 x 10, DIN912, A2 4 See Kit, fasteners,pneumatic assy

9 311715 Plate, shaft, seal, air motor 1

10 ‐ Glide ring 12 x 2.85 1 See Kit, pneumatic

11 ‐ O‐ring, 13.95 x 2.62, Viton 1 See Kit, pneumatic

12 7300185 Cylinder, air motor, pump, LA300 1

13 7303562 Retaining ring, 12 mm, DIN471, corr. Res. 1 See Kit, pneumatic

14 7300191 Piston lower, air motor, ø 70 mm, pump, LA300 1

15 ‐ O‐ring 9.25 x 1.78, Viton 2 See Kit, pneumatic

16 7300190 Rod, piston airmotor, ø 70 mm, pump, LA300 1

17 311553 Cover plug, ø 13.2 mm, plastic 1

18 311620 Coupling, air, fem. 7.2 ‐ hose barb 10 mm 1

19 311624 Coupling, air, male 7.2 ‐ male G1/4” 1

20 7300229 Filter/regulator, pneumatic 1

21 7304144 Male Thr. Coupling, D=10mm, G 1/4, brass 1

22 7303894 Air connector, M10, Di= 6mm, brass 1

23 7304133 Air valve, 5/2 air operated, LA3XX 1 Screws and gasketincluded

24 Screw, allenhead, M4 x 12, DIN912, A2 14 See Kit, fasteners,pneumatic assy

25 7303893 Manifold, air motor, LA 300 1

26 7304395 Gasket for air valve, LA 3XX 1

27 312500 Gauge. pressure, 0-6 Bar, G 1/4 1

28 313017 Nipple, air, brass, 1 /8“ male- 1 /8“ female 1

29 ‐ Gasket, manif. Airmtr, str. 75 mm, Pump LA300 1 See Kit, pneumatic

Page 56: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

44 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

Assembly, hydraulic (std.)

3 1 2 21 22 8 23 8 7

27

9

10

28

15654

20

19

18

17

16

24

11

25

26

14

12

13

29

30

Fig. 27 Assembly, hydraulic (std.)

Page 57: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Piston pump LA 300 45

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

Item Part Description Qty Remarks

7302234 Assembly, hydraulic (std.), pump, LA300

1 7300211 Adapter, air motor‐hydraulic assembly, pump,LA300

1

2 ‐ Wear ring, air motor, LA piston pump 1 See Kit, hydraulicSee Kit, hydraulic, small

3 ‐ Scraper, air motor, LA piston pump 1 See Kit, hydraulicSee Kit, hydraulic, small

4 7300210 Oil chamber, pump, LA300 1

5 ‐ Washer, spring, M8, DIN7980, A2 3 See Kit, fasteners,hydraulic assembly

6 ‐ Screw, allenhead, M8 x 90, DIN912, A2 3 See Kit, fasteners,hydraulic assembly

7 7300219 Screw plug, hex, M16 x 1.5, DIN908, A4 1

8 ‐ Set screw, M5 x 8, DIN915, A2 2 See Kit, fasteners,hydraulic assembly

9 7300201 Mounting bracket, pump, LA300 1

10 ‐ Washer, spring, M5, DIN7980, A2 2 See Kit, fasteners,hydraulic assembly

11 ‐ Screw, allenhead, M5 x 12, DIN912, A2 2 See Kit, fasteners,hydraulic assembly

12 7300222 Pin, dowel, D4m6 x 40, DIN7, A2 1

13 311208 Ball, 20 mm 1

14 ‐ O‐ring, 44.17 x 1.78, Aflas 1 See Kit, hydraulic, small

15 7302264 Seat, valve, ball, LA piston pump 1

16 377901 Plug, ø 8 mm 1

17 377978 Label ”Attention: Fill with oil” 1

18 ‐ Pressure ring, seal, pump, LA300 1 See Kit, hydraulic, small

19 ‐ Seal, rod, LA piston pump 1 See Kit, hydraulic

20 7300183 Spring, compression, 3.5 x 30 x 51 mm 1

21 ‐ Pin, retaining, D= 1.5 mm, R= 12 mm, SS 1 See Kit, hydraulic, small

22 7300471 Rod, L= 75 mm, basic, LA piston pump 1

23 ‐ Snap ring, SW‐55 x 1.5, galZn, pump, LA300 1 See Kit, hydraulic, small

24 7300198 Manifold, radial, pump, LA300 1

25 ‐ Valve, ø 35 mm, LA piston pump 1 See Kit, hydraulic

26 7300195 Seat, Valve, LA piston pump 1

27 ‐ O‐ring, 47.22 x 3.53, Aflas 2 See Kit, hydraulic, small

28 7300184 Cylinder, stroke 75 mm, pump, LA300 1

29 7300235 Lubricant, 100 ml, LA piston pump 1 See Lubricants and Adhesives

30 ‐ O‐ring, 20.30 X 2.62, EPDM 1 See Kit, hydraulic, small

Page 58: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

46 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

Assembly, hydraulic (w.r.)

3 1 2 21 22 8 23 8 7

27

9

10

28

15654

20

19

18

17

16

24

11

25

26

14

12

13

29

30

Fig. 28 Assembly, hydraulic (w.r.)

Page 59: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Piston pump LA 300 47

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

Item Part Description Qty Remarks

7303133 Assembly, hydraulic (w.r.), pump, LA300

1 7300211 Adapter, air motor‐hydraulic assembly, pump,LA300

1

2 ‐ Wear ring, air motor, LA piston pump 1 See Kit, hydraulicSee Kit, hydraulic, small

3 ‐ Scraper, air motor, LA piston pump 1 See Kit, hydraulicSee Kit, hydraulic, smal

4 7300210 Oil chamber, pump, LA300 1

5 ‐ Washer, spring, M8, DIN7980, A2 3 See Kit, fasteners,hydraulic assembly

6 ‐ Screw, allenhead, M8 x 90, DIN912, A2 3 See Kit, fasteners,hydraulic assembly

7 7300219 Screw plug, hex, M16 x 1.5, DIN908, A4 1

8 ‐ Set screw, M5 x 8, DIN915, A2 2 See Kit, fasteners,hydraulic assembly

9 7300201 Mounting bracket, pump, LA300 1

10 ‐ Washer, spring, M5, DIN7980, A2 2 See Kit, fasteners,hydraulic assembly

11 ‐ Screw, allenhead, M5 x 12, DIN912, A2 2 See Kit, fasteners,hydraulic assembly

12 7300222 Pin, dowel, D4m6 x 40, DIN7, A2 1

13 311208 Ball, 20 mm 1

14 ‐ O‐ring, 44.17 x 1.78, Aflas 1 See Kit, hydraulic, smal

15 7302264 Seat, valve, ball, LA piston pump 1

16 377901 Plug, ø 8 mm 1

17 377978 Label ”Attention: Fill with oil” 1

18 ‐ Pressure ring, seal, pump, LA300 1 See Kit, hydraulic, small

19 ‐ Seal, rod, LA piston pump 1 See Kit, hydraulic

20 7300183 Spring, compression, 3.5 x 30 x 51 mm 1

21 ‐ Pin, retaining, D= 1.5 mm, R= 12 mm, SS 1 See Kit, hydraulic, small

22 7303263 Rod, L= 75 mm, w.r., LA piston pump 1

23 ‐ Snap ring, SW‐55 x 1.5, galZn, pump, LA300 1 See Kit, hydraulic, small

24 7300198 Manifold, radial, pump, LA300 1

25 ‐ Valve, ø 35 mm, LA piston pump 1 See Kit, hydraulic

26 7300195 Seat, Valve, LA piston pump 1

27 ‐ O‐ring, 47.22 x 3.53, Aflas 2 See Kit, hydraulic, small

28 7300184 Cylinder, stroke 75 mm, pump, LA300 1

29 7300235 Lubricant, 100 ml, LA piston pump 1 See Lubricants andAdhesives

30 ‐ O‐ring, 20.30 x 2.62, EPDM 1 See Kit, hydraulic, small

Page 60: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

48 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

Assembly, suction hose

2

3

2

4

1

Fig. 29 Assembly, suction hose

Item Part Description Qty Remarks

1

7303800

7303801

Assembly, suction hose, 5/8”, pump, LA300

Fitting, hose, 16 mm x G1/2, pump LA 300

1

1

2 313667 Hose clamp, 15‐24 mm / 12mm, SS 2

3 7303804 Hose, ID= 16 mm, PVC, reinforced, 2 mtr. 1

4 7303799 Assembly, non return valve 5/8“, pump, LA300 1 See Assembly, non returnvalve

Page 61: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Piston pump LA 300 49

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

Assembly, non return valve

1

2

3

4

5

Fig. 30 Assembly, non return valve

Item Part Description Qty Remarks

1

7303799

7303803

Assembly, non return valve 5/8“, LA piston pump

Fitting, non return valve, LA piston pump

1

2 7303806 Spring, compression 17.5 x 1 x 42, DIN17224 1

3 311208 Ball, 20 mm 1

4 7303802 Seat, non return valve, LA piston pump 1

5 313941 Filter element, G1” 1

Page 62: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

50 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

Assembly, wall‐mount

7

6

10

2

5

9

8

1

3

4

Fig. 31 Assembly, wall‐mount

Item Part Description Qty Remarks

‐ 7300449 Kit, Lid, ø 315 mm, wall-mount, LA piston pump ‐ Item 1-10

‐ 7300390 Kit, Lid, ø 400 mm, wall-mount, LA piston pump ‐ Item 1-10

1 7300447 Lid, ø 315 mm, wall-mount, LA piston pump 1

7300391 Lid, ø 400 mm, wall-mount, LA piston pump -

2 312329 Handle, 117 mm 2 See Kit, handles, lid

3 ‐ Screw, allenhead, M8 x 25, DIN912, A2 4

4 ‐ Washer, spring, M8, DIN7980, A2 4

5 7304148 Reducing ring PG36/PG29, plastic 1

6 7304149 Cable gland, PG29, plastic 1

7 7300163 Plug, flanged, plastic, ø 12 mm 1

8 7304318 Plug, flanged, plastic, ø 20 mm 1

9 7300392 Cable gland, PG36, plastic 1 For 1 inch hose

10 7302228 Pump, piston, LA300, standard 1

7302240 Pump, piston, LA300, wear resistant 1

Page 63: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Piston pump LA 300 51

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

Assembly, lid‐mount

7

8

2

3 14 4 3

256

Fig. 32 Assembly, lid‐mount

Item Part Description Qty Remarks

‐ 7300450 Assembly, lid, pump, SS, ø 315 mm, pump,LA300

1 Item 1 ‐ 6

‐ 7300418 Assembly, lid, pump, SS, ø 400 mm, pump,LA300

1 Item 1 ‐ 6

1 7300448 Lid, pump, ø 315 mm, SS, pump, LA300 1

7300402 Lid, pump, ø 400 mm, SS, pump, LA300 1

2 312329 Handle, 117 mm 2 See Kit, handles, lid

3 ‐ Washer, spring, M8, DIN7980, A2 4 See Kit, handles, lid

4 ‐ Screw, allenhead, M8 x 12, DIN912, A2 4 See Kit, handles, lid

5 7300393 Plug, flanged, plastic, ø 14.6 mm 2

6 7300394 Plug, flanged, plastic, ø 6.6 mm 1

7 7302228 Pump, piston, LA300, standard 1

7302240 Pump, piston, LA300, wear resistant 1

8 377912 Pressure regulator, LA381, 0‐7 bar / 100PSI 1

377894 Pressure regulator, LA382, 0‐18 bar / 250PSI 1

377970 Pressure regulator, LA383, 0‐48 bar / 700PSI 1

Page 64: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

52 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

Pump, wall‐mount, detached filter

1 2 3 2

1

4

Fig. 33 Pump, wall‐mount, detached filter

Item Part Description Qty Remarks

1 7302228 Pump, piston, LA300, standard 1

7302240 Pump, piston, LA300, wear resistant 1

2 7300410 Fitting, M16 x 1.5‐3 / 4‐16 UNF, male‐male 2

3 7300411 Hose, remote filter, 1.5 mtr. pump, LA300 1

7300412 Hose, remote filter, 3.0 mtr. pump, LA300 1

7300413 Hose, remote filter, 6.0 mtr. pump, LA300 1

7300414 Hose, remote filter, 9.0 mtr. pump, LA300 1

4 7300409 Assembly, bracket, remote filter, pump,LA300

1

Page 65: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Piston pump LA 300 53

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

Pump, console‐mount

3

4

2

1

Fig. 34 Pump, console‐mount

Item Part Description Qty Remarks

1 7302228 Pump, piston, LA300, standard 1

7302240 Pump, piston, LA300, wear resistant 1

2 7300449 Kit, lid, ø 315 mm, wall‐mount, LA piston pump 1

7300390 Kit, lid, ø 400 mm, wall‐mount, LA piston pump 1

3 377912 Pressure regulator, LA381, 0‐7 bar / 100PSI 1

377894 Pressure regulator, LA382, 0‐18 bar / 250PSI 1

377970 Pressure regulator, LA383, 0‐48 bar / 700PSI 1

4 Adhesive system console (ASC) 1

Page 66: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

54 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

Kit, hydraulic

1

2

3

4

Fig. 35 Kit, hydraulic

Item Part Description Qty Remarks

‐ 7300112 Kit, hydraulic, pump, LA piston pump 1

1 7300221 Wear ring, air motor, LA piston pump 1

2 7300220 Scraper, air motor, LA piston pump 1

3 7300216 Seal, rod, LA piston pump 1

4 7300199 Valve, ø 35 mm, LA piston pump 1

‐ 7300235 Lubricant, 100 ml, LA piston pump ‐ See Lubricants andAdhesives

Page 67: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Piston pump LA 300 55

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

Kit, hydraulic, small

1

3

8

2

4

5

6

7

9

Fig. 36 Kit, hydraulic, small

Item Part Description Qty Remarks

‐ 7302458 Kit, hydraulic, small, pump, LA300 1

1 7300228 Pin, retaining, D= 1.5 mm, R= 12 mm, SS 1

2 7300224 O‐ring, 20.30 x 2.62, EPDM 1

3 7300221 Wear ring, air motor, LA piston pump 1

4 7300220 Scraper, air motor, LA piston pump 1

5 7300196 Pressure ring, seal, pump, LA300 1

6 7300223 O‐ring, 44.17 x 1.78, Aflas 1

7 7300218 O‐ring, 47.22 x 3.53, Aflas 2

8 7300217 Snap ring, SW‐55 x 1.5, galZn, pump, LA300 1

9 7300235 Lubricant, 100 ml, LA piston pump 1 See Lubricants andAdhesives

Page 68: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

56 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

Kit, pneumatic

1 2

7

5

3

6

3

8

4

Fig. 37 Kit, pneumatic

Item Part Description Qty Remarks

‐ 7300109 Kit, pneumatic, pump, LA300

1 ‐ Nut, hex, M8, DIN985, galZn 1

2 313934 O‐ring 8.5 x 2, Viton 1

3 7300197 Seal, piston, ø 70 mm, air motor, pump, LA300 2

4 311476 Glide ring 12 x 2.85 1

5 311494 O‐ring, 13.95 x 2.62, Viton 1

6 7303562 Retaining ring, 12 mm 1

7 311488 O‐ring 9.25 x 1.78, Viton 1

8 7300187 Gasket, manifold air motor, str. 75 mm, pump,LA300

1

Page 69: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Piston pump LA 300 57

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

Kit, filter

44

1 2

3

5

Fig. 38 Kit, filter

Item Part Description Qty Remarks

‐ 7300110 Kit, filter, pump, LA300 1

1 7300205 Seal, interior, filter lid, LA piston pump 1

2 7300215 O‐ring, 47.35 x 1.78, Aflas 1

3 312291 Filter cartridge, 50 mesh 1

4

5

7300214

374779

O‐ring, 21.9 x 2.62, Aflas

O‐ring, 4.47 x 1.78, Aflas

2

1

Page 70: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

58 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

Kit, fasteners

(without illustration)

Kit, fasteners, filter assembly

Item Part Description Qty Remarks

‐ 7303363 Kit, fasteners, Pneumatic Assy

1 - Washer, spring, M4, DIN7980, A2 10

2 - Nut, hex, M8, DIN985, galZn 1

3 - Screw, allenhead, M4x10, DIN912, A2 4

4 - Screw, allenhead, M4x12, DIN912, A2 16

Kit, fasteners, pneumatic assembly

Item Part Description Qty Remarks

‐ 7303363 Kit, fasteners, pneumatic assembly ‐

1 ‐ Washer, spring, M4, DIN7980, A2 2

2 ‐ Nut, hex, M8, DIN985, galZn 1

3 ‐ Screw, allenhead, M4 x 10, DIN912, A2 4

4 ‐ Screw, allenhead, M4 x 12, DIN912, A2 16

5 ‐ Screw, allenhead, M3 x 30, DIN912, A2 2

Kit, fasteners, hydraulic assembly

Item Part Description Qty Remarks

‐ 7303364 Kit, fasteners, hydraulic assembly, LA300 ‐

1 ‐ Set screw, M5 x 8, DIN915, A2 2

2 ‐ Washer, spring, M8, DIN7980, A2 3

3 ‐ Screw, allenhead, M8 x 90, DIN912, A2 3

4 ‐ Screw, allenhead, M5 x 12, DIN912, A2 2

5 ‐ Washer, spring, M5, DIN7980, A2 2

Page 71: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Piston pump LA 300 59

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

Kit, hose, flush/return

3

2

1

4

2

Fig. 39 Kit, hose, flush/return

Item Part Description Qty Remarks

‐ 7300113 Kit, hose, flush/return, SS, pump, LA300 ‐

1 7303167 Hose, air, ID= 6 mm, 2 mtr. 1

2 7300093 Hose clamp, 8‐14 mm / 9 mm, SS 1

3 7300094 Fitting, hose, 6 mm x G1/8 male, SS 1

4 7300095 Fitting, hose, 6 mm x G1/4 male, SS 1

Page 72: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

60 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

Kit, handles, lid

1

4

3

4

232

Fig. 40 Kit, handles, lid

Item Part Description Qty Remarks

‐ 7303438 Kit, handles, lid, LA piston pump ‐

1 312329 Handle, 117 mm 2

2 ‐ Screw, allenhead, M8 x 12, DIN912, A2 4 For 7300450 / 7300418

3 ‐ Screw, allenhead, M8 x 25, DIN912, A2 4 For 7300449 / 7300390

4 ‐ Washer, spring, M8, DIN7980, A2 4

Page 73: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Piston pump LA 300 61

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

Lubricants and Adhesives

Item Description Application Remarks

‐ Loctite 577 (thread sealant) for screw fittings AR

‐ OKS250 (white paste) for stainless steelthreads

AR

311642 Sil. grease tube (50 gr) for O‐rings AR

‐ Loctite 555 (seal tape without for the pressure reliefvalve

AR

7300235 Lubricant, 100 ml, LA piston pump for the oil chamber 1

AR: As Required

Adhesive hose

Fig. 41 Adhesive hose

Length (m) Part

0,25 312 256

0,5 312 257

1,0 312 259

2 312 266

2,5 312 267

3 312 268

4 312 270

6 312 273

gretchen.wangerin
Typewritten Text
PTFE)
gretchen.wangerin
Typewritten Text
gretchen.wangerin
Typewritten Text
gretchen.wangerin
Typewritten Text
Page 74: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

62 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

Technical Data

General Information

Pump type LA 300

Feed capacity 2.0 l/min (0.5 usgal/min)

Max. suction 4 m (with water)

Pressure ratio 7:1

Adhesive connections 1/2”‐20UNF outside thread

Max. adhesive pressure 42 bar (610 PSI)

Min. air pressure 0.6 bar (8.7 PSI)

Max. air pressure** 6 bar (87 PSI)

Compressed air connection Quick‐coupling plug fitting, size 7.2(Europrofil DIN 14152‐1)Delivery includes the proper coupling with ahose nozzle for a pneumatic hose with an innerdiameter of 10 mm.

Requiredcompressed air

Dry, nonlubricated, filtered < 40µ,within a permitted range of4.5 ‐ 7 bar (65 ‐ 100 PSI)

Compressed airconsumption

1.8 normal l/sec. at 30 cycles/min(3.8 Scfm)

Permittedambient temperature

1° C ‐ +50 ° C = 33 ° F ‐ 120 ° F

Max.relative humidity

95 %

Noise emission ≥ 70 db(A) (ear protection required)

Weight 15.5 kg (15.42 kg)

** When operating with a low flow rate, set the air pressure no higher than4 bar.

NOTE: 1 bar = 14.5 PSI

NOTE: 25.4 mm = 25.40 mm

NOTE: 0.4536 kg = 0.45 kg

NOTE: 9 x °C/5 + 32 = °F

Page 75: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

Piston pump LA 300 63

P/N 7105256_05� 2012 Nordson Corporation LA 300Edition 01/12

Pump dimensions

115 mm

(11.51 cm.)

90 mm

(8.99 cm.)

ø 9 mm (4x)

(8.89 mm.)

60

mm

(5.9

9 c

m.)

57

1.5

0 m

m

(57

.15

cm

.)

40

0 m

m

(40

.01

cm

.)

10

0 m

m

(10

.01

cm

.)

ø 96.50 mm

(9.65 cm.)

220.50 mm

(22.05 cm.)

2,0

00

mm

(10

0.0

0 c

m.)

ø 16 mm

(5/8 in.)

Fig. 42 Pump dimensions

Page 76: Piston Pump LA 300 - Welcome to Nordson eManuals!emanuals.nordson.com/adhesives/English_Manuals/7105256.pdfEnglish − Table of Contents I 2012 Nordson Corporation LA 300 P/N 7105256_05

64 Piston pump LA 300

P/N 7105256_05 � 2012 Nordson CorporationLA 300Edition 01/12

Permissible hose lengths for a wall‐mounted pump

40

0 m

m

ø 400 mm

ma

x.

4 m

Fig. 43 Permissible hose lengths for a wall‐mounted pump