PIPELESS™ PORTABLE FOOT BATH WITH SEAL-LESS JET … · WARNING: When using this unit, basic...

16
Purity is Premium PIPELESS™ PORTABLE FOOT BATH WITH SEAL-LESS JET TECHNOLOGY OWNER’S MANUAL Models: SFB2-S115-XX (115v, 60Hz) 2 Jet – Dual Speed

Transcript of PIPELESS™ PORTABLE FOOT BATH WITH SEAL-LESS JET … · WARNING: When using this unit, basic...

Page 1: PIPELESS™ PORTABLE FOOT BATH WITH SEAL-LESS JET … · WARNING: When using this unit, basic precautions should always be followed, including the following: 1. IMPORTANT: Read complete

Purity is Premium

PIPELESS™ PORTABLE FOOT BATH WITH SEAL-LESS JET TECHNOLOGY

OWNER’S MANUAL

Models: SFB2-S115-XX (115v, 60Hz) 2 Jet – Dual Speed

Page 2: PIPELESS™ PORTABLE FOOT BATH WITH SEAL-LESS JET … · WARNING: When using this unit, basic precautions should always be followed, including the following: 1. IMPORTANT: Read complete

Dear Valued Customer:

Thank you for purchasing the SANIJET Pipeless™ Portable Foot Bath. As the innovator of Pipeless™

hydromassage, SANIJET® was founded on the principle that, in spa bath and pedicure bath systems,

purity is premium.

SANIJET’s Reflexology Foot Baths, Pedicure Sinks and Portable Foot Baths provide safe hydromassage,

quiet operation, and the ability for quick and easy system disinfection.

Please read and follow all of the instructions contained in this Manual before installing, operating, or

maintaining your new SANIJET Pipeless™ Portable Foot Bath.

Before proceeding, please take a few minutes to complete the warranty registration enclosed in your

Owner’s packet and submit it to SANIJET at the address provided on the form.

If you have questions concerning installation, operation or maintenance, please contact a SANIJET

technical service representative toll-free at (877) 934-0477.

Sincerely,

SANIJET®

Page 3: PIPELESS™ PORTABLE FOOT BATH WITH SEAL-LESS JET … · WARNING: When using this unit, basic precautions should always be followed, including the following: 1. IMPORTANT: Read complete

General Information .......................................................................................................1

Limited Commercial Warranty ....................................................................................... 2

Safety ........................................................................................................................... 3

Electrical ....................................................................................................................... 4

Features and Specifications .......................................................................................... 5

Operating Instructions................................................................................................... 7

Dry Run Protection ........................................................................................................8

How To Drain ................................................................................................................. 9

Cleaning and Care.........................................................................................................10

Troubleshooting ...........................................................................................................12

Table of Contents

Page 4: PIPELESS™ PORTABLE FOOT BATH WITH SEAL-LESS JET … · WARNING: When using this unit, basic precautions should always be followed, including the following: 1. IMPORTANT: Read complete

1

This product was completely water-tested, securely packaged and in good condition when delivered

to the carrier. Immediately upon receipt, inspect the unit for any obvious damage BEFORE installing.

Retain the shipping carton and packing material to reuse in case service becomes necessary. Should

the inspection reveal damage or defect, do not install the unit.

SANIJET’s responsibility for shipping damage ceases upon delivery of the product in good condition to

the carrier. It is the responsibility of the recipient to inspect the packaging for damage. Any damage

claims must be filed with the carrier within 2 business days from receipt of shipment. All returns will

be refused unless accompanied by a Return Material Authorization (RMA) Form.

For definitions of warranty coverage and limitations, refer to the published warranty information on

Page 2.

General Information

Page 5: PIPELESS™ PORTABLE FOOT BATH WITH SEAL-LESS JET … · WARNING: When using this unit, basic precautions should always be followed, including the following: 1. IMPORTANT: Read complete

Limited Commercial WarrantyPEDICURE EQUIPMENT LIMITED COMMERCIAL WARRANTY

PRODUCTS COVERED: Pedicure Sinks, Reflexology Foot Baths and Portable Foot Baths, manufactured by SANIJET and put to commercial use.

PERSONS COVERED: The original purchaser for commercial use (Customer).

WARRANTY PERIOD: One (1) year on all parts and components beginning on the date of original purchase for use or two (2) months after the product leaves SANIJET’s facility, whichever comes first. SANIJET may require Customer to document the date of original purchase and provide serial number(s) of the product(s).

SCOPE OF COVERAGE: This warranty only covers problems reported to SANIJET during the warranty period. Coverage is SUBJECT TO the exclusions below. If a tub shell manifests a defect or fails to properly perform under ordinary use within the warranty period, SANIJET will repair or replace it at SANIJET’s election, but shall have no responsibility with respect to removal, reinstallation or transport of the tub shell. If any other part or component manifests a defect or fails to properly perform under ordinary use during the warranty period, SANIJET will provide repair or replacement parts or components at its election. As a condition to warranty service, SANIJET may require Customer to return defective/malfunctioning parts and may charge Customer for the repair or replacement parts or components subject to a full refund upon receipt of the return parts and verification of the problem. THE REMEDY PROVIDED IN THIS SECTION IS CUSTOMER’S EXCLUSIVE REMEDY FOR ANY DEFECT OR MALFUNCTION OF THE PRODUCT.

SHIPPING: SANIJET will pay freight on a least-cost basis to ship repair/replacement parts to destinations within the continental United States.

EXCLUSIONS: This warranty does NOT cover a) metallic plated hardware, light bulbs or fading from exposure to direct sunlight; b) failure, damage or defect caused by any of the following after the product leaves SANIJET’s factory: mishandling, abuse, misuse, neglect, accident or natural disaster, normal wear and use that does not affect the product’s function; failure to maintain the product as recommended by SANIJET (See Owner’s/Installation manual); or c) any part that has been altered or tampered with, including but not limited to alteration or tampering with any labeling.

MAKING CLAIMS: Report problems to SANIJET’s customer service department.Telephone: 877-934-0477 or 972-745-2283 Fax: 214-352-0348 E-mail: [email protected]

DEALER WARRANTIES: No dealer or distributor has any authority to bind SANIJET to any other warranty or any change or addition to this warranty.

SOLE REMEDY / LIMITATION OF DAMAGES: THE REMEDY PROVIDED ABOVE UNDER “SCOPE OF COVERAGE” IS CUSTOMER’S EXCLUSIVE REMEDY FOR ANY DEFECT OR MALFUNCTION OF THE PRODUCT. To the fullest extent allowed by law, SANIJET disclaims and excludes liability for consequential and incidental damages including, but not limited to, loss of use, lost rentals, lost profits, loss of business reputation, out of pocket expenses, damage to property other than the warranted product, mental anguish and punitive damages. Some states limit or do not allow the exclusion or limitation of incidental or consequential damages, so some or all of these limitations may not apply to you.

STATE LAW RIGHTS: This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. THE DURATION OF ANY IMPLIED WARRANTIES UNDER STATE LAW, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS LIMITED TO THE WARRANTY PERIOD DESCRIBED ABOVE. Some states do not allow limitations on how long an implied warranty lasts, so this limitation may not apply to you.

2

Page 6: PIPELESS™ PORTABLE FOOT BATH WITH SEAL-LESS JET … · WARNING: When using this unit, basic precautions should always be followed, including the following: 1. IMPORTANT: Read complete

3

Safety

SAVE THESE INSTRUCTIONSWARNING: WHEN USING THIS UNIT, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING:

INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS

1. READ AND FOLLOW ALL INSTRUCTIONS2. WARNING: Risk of accidental injury or drowning: Children or handicapped persons should not use pedicure spa without

adult supervision.3. WARNING: To avoid injury, exercise care when using a pedicure spa.4. WARNING: Risk of electric shock: Do not permit electric appliances (such as a hair dryer, lamp, telephone, radio, or

television) to be within 5 ft (1.5 m) of this unit.5. DANGER: RISK OF ELECTRIC SHOCK: This unit should be grounded. Connect only to a dedicated 15 amp circuit that is

protected by a Ground Fault Circuit Interrupter (GFCI). A GFCI should be provided by the electrician and should be tested on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, there is a possibility of a ground fault, or defective GFCI. DO NOT USE THE UNIT. Have the problem corrected by a qualified service representative or an electrician before using.

6. WARNING: Use the Pipeless™ Pedicure Bath only for its intended purpose: a fill and drain indoor appliance for foot and ankle hydromassage. DO NOT use attachments not recommended by manufacturer.

7. RISK OF ELECTRIC SHOCK: Disconnect from the electrical supply before servicing.

WARNING

1. DO NOT reach for any electrical object that has fallen into water. Unplug immediately.2. DO NOT drop or insert anything into any jet opening.3. DO NOT operate this unit without the complete jet assembly installed or without water filled 1 in (3 cm) above the jets .4. DO NOT overfill the basin.5. DO NOT stand on or in the basin, or on the foot rest.6. DO NOT leave this appliance unattended when in operation.7. Keep the electrical cord away from heated surfaces.8. Connect this appliance only to a properly grounded outlet (See Grounding Instructions on Page 4).9. To avoid injury, exercise care when entering or exiting the pedicure spa.10. It is important that you clean and disinfect the jets and basin after every use. Unless thoroughly cleaned after each use,

bath residue will buildup within the jets and on the surface area of any whirlpool pedicure spa, which can promote the growth of infectious bacteria.

11. Hydromassage should be pleasant and comfortable. Should you experience any pain or discomfort while using the pedicure spa, discontinue use immediately and consult your physician.

12. Consult your physician if you are diabetic, have poor circulation, or if any area of your feet or legs is inflamed, has an open wound or if you have any other questions about whether you should be using hydromassage equipment.

13. SANIJET recommends a qualified plumber and electrician install your Pipeless™ Pedicure Bath.14. Water supply temperature to the Pipeless™ Pedicure Bath MUST NOT exceed 106° F (41° C). Water temperature in excess

of 106° F (41° C) may be injurious to users health. Check water temperature and adjust prior to use.

INSTALLER / OWNER BEARS ALL RESPONSIBILITIES TO COMPLY WITH ALL STATE AND LOCAL CODES WHEN

INSTALLING THIS PRODUCT. FAILURE TO COMPLY WITH THESE INSTRUCTIONS MAY VOID WARRANTY.

Page 7: PIPELESS™ PORTABLE FOOT BATH WITH SEAL-LESS JET … · WARNING: When using this unit, basic precautions should always be followed, including the following: 1. IMPORTANT: Read complete

4

Electrical

INSTRUCTIONS PRIOR TO USEWARNING: When using this unit, basic precautions should always be followed, including the following:

1. IMPORTANT: Read complete instructions before use. Each Pipeless™ Foot Bath arrives ready for use.

2. This unit requires a 115 VAC, 60 Hz, 2 Amp service and is provided with a 10 ft (3 m) cord with an integral Ground Fault Circuit Interrupter (GFCI) and NEMA 5-15 Plug. A grounded electrical outlet is required.

3. Remove the foot bath from the carton and retain the shipping carton and packing material to reuse in case service becomes necessary. DO NOT lift the foot bath by its handle or electrical cord.

GROUNDING INSTRUCTIONS

This unit must be grounded. The integral GFCI should be tested on a routine basis. To test the GFCI, push the test button.

The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this

manner, there is a ground fault, indicating the possibility of electrical shock. DO NOT USE THE UNIT. Disconnect the unit

and have the problem corrected by a qualified service representative or an electrician before using.

Page 8: PIPELESS™ PORTABLE FOOT BATH WITH SEAL-LESS JET … · WARNING: When using this unit, basic precautions should always be followed, including the following: 1. IMPORTANT: Read complete

5

Features and Specifications

Product Specifications Are Subject To Change Without Notice.

Pipeless™ Portable Foot Bath

FEATURES

• TwoPatented,HighPerformance,Ultra-QuietPipeless™Jets

• AdvancedSeal-lessTechnologyDesignedforMaintenance-FreeUse

• CompleteHygienewithSimpleFiveMinuteDisinfectionProtocol

• TwoPieceLidwithClientFootRestforComfort

• RollingCastersandEasytoUseHandle

• DischargePumpandFillHose

• Durable,HighGlossAcrylicConstructioninWhiteorBiscuit

Page 9: PIPELESS™ PORTABLE FOOT BATH WITH SEAL-LESS JET … · WARNING: When using this unit, basic precautions should always be followed, including the following: 1. IMPORTANT: Read complete

6

Features and Specifications Continued

Product Specifications Are Subject To Change Without Notice.

Pipeless™ Portable Foot Bath

SPECIFICATIONS

• Width:20.0”(51cm)xLength:27.0”(69cm)xHeight:15.0”(38cm)

• Material:Structurallyreinforcedcastacrylic

• OperatingCapacity:4.5Gallons(17L)

• ApproximateShipWeight:42lbs(19kg)

• WaterFlowRate:14gallonsperminute(53L)

• ElectricalRequirements

115 VAC, 60 Hz, 15 amp, dedicated GFCI service 10 ft (3 m), 16/3 power cord included

DIMENSIONS

27”[69 cm]

20”[51 cm]

15”[38 cm]

Page 10: PIPELESS™ PORTABLE FOOT BATH WITH SEAL-LESS JET … · WARNING: When using this unit, basic precautions should always be followed, including the following: 1. IMPORTANT: Read complete

7

Operating Instructions

1. Fill the Portable Foot Bath with water, at the desired temperature, 1 in (3 cm) above the jets.

2. Move the unit to the place where it will be used and be sure that it is on a level, solid floor. Note: The front two

casters have locking mechanisms to prevent the unit from moving during use. Be sure the locking mechanisms are

disengaged before attempting to move the unit. A handle is built into the top of the unit for easy maneuverability.

Before moving the unit filled with water, place the two removable lids on the tank to prevent water from splashing

onto the floor.

3. Verify that the unit’s electrical cord is connected to a GFCI protected electrical outlet.

4. To start or stop this appliance turn the dial switch to the ON or OFF position.

5. Bath additives , including oil based products , can be used in a SANIJET Pipeless™ Pedicure Bath, since their residue

can be easily cleaned.

CAUTION: Use only low foaming additives , and do not use products that contain sand or silicates .

6. You should always be in a seated position when putting your feet in or removing them from the pedicure bath.

WARNING: NEVER STAND IN THE PEDICURE BATH BASIN.

7. During use of the foot bath the front lid can be used as a foot rest as well as assist in maintaining water temperature

and reduce splashing.

Quarter-turnCounterClockwise

Page 11: PIPELESS™ PORTABLE FOOT BATH WITH SEAL-LESS JET … · WARNING: When using this unit, basic precautions should always be followed, including the following: 1. IMPORTANT: Read complete

8

Dry Run Protection

IMPORTANT•BEFOREUSEcheckthemagneticimpellerrotorisproperlyinstalledinthecasemotorassembly.

•BEFOREUSEmakesurethatwaterisfilledtoatleast1in(3cm)abovethejetsforproperoperation.

•DONOTattempttoactivatethejetsonthePipeless™pedicurebathwithoutwaterpresent.

DRY RUN PROTECTIONThe Pipeless™ Pedicure Foot Bath is equipped with an advanced Dry Run Sensor to ensure water is present for proper

jet operation. When the motor is turned ON and no water is present, the motor will run in the “no load” condition for 30

seconds then shut off for 15 seconds . After 15 seconds the motor will turn back ON. If the motor does not sense a load

after 8 seconds, it will shut off again for another 15 seconds . The motor will repeat this sequence a total of 10 times before

going into standby mode. Resetting the motor requires cycling the main power to the motors OFF and then back ON (unplug

system and wait 5 seconds, then plug power supply back in again).

SAFETY SHUTOFF SENSORThe Pipeless™ Pedicure Bath is equipped with a safety shutoff sensor. The jet assemblies must be properly installed for use

and will not operate if not aligned or assembled correctly.

The jet assemblies must be properly

locked in “run” position at the 3 or 9

o’clock position to operate.

The separator plate must be properly

installed in the escutcheon to operate.

3 o’clock“run” Position

9 o’clock“run” Position

Separator Plate

SensorMagnets

Escutcheon

Jet Discharge Port

Page 12: PIPELESS™ PORTABLE FOOT BATH WITH SEAL-LESS JET … · WARNING: When using this unit, basic precautions should always be followed, including the following: 1. IMPORTANT: Read complete

9

How To Drain

PROCEDURE TO DRAIN THE FOOT BATH

1. Turn off the foot bath by pushing the OFF button on the control module.

2. Unplug the foot bath from the electrical outlet and store the cord.

3. Put both removable lids on the tank before moving the foot bath to the area where the tank will be drained and then

remove the lids .

4. Place the Discharge Pump on the flat round surface in the bottom of the foot bath. (See Image # 1)

5. Extend the hose connected to the Discharge Pump to the area where the water is to be drained (sink). Use the

suction cup provided to secure the hose to the side of the sink and turn on the discharge pump by plugging the

pump’s power cord into a grounded circuit. (See Image # 2)

6. When the foot bath appears to be empty, continue running the pump while removing it from the interior of the foot

bath and place it in the sink or chosen draining area. As soon as the pump and hose are both fully in the sink unplug

the power cord to turn off the discharge pump. Fresh water can be used to rinse out the tank during the draining

procedure. (See Image # 2)

WARNING: Do not leave the pump running in the draining area or in a dry foot bath for more than a few seconds

because it may result in damage to the discharge pump.

WARNING: The power cord cannot be replaced; in case of any damage to the power cord the entire discharge pump

must be replaced.

To maintain your SANIJET® Pipeless™ Portable Foot Bath at a maximum level of hygiene, thoroughly clean the tub shell

and jets after each use with a nonabrasive antibacterial cleaner, rinse thoroughly, and dry completely. See Page 10 for

complete cleaning procedure. NEVER use abrasive cleaners on the foot bath.

Image #1 Image #2

Page 13: PIPELESS™ PORTABLE FOOT BATH WITH SEAL-LESS JET … · WARNING: When using this unit, basic precautions should always be followed, including the following: 1. IMPORTANT: Read complete

10

Cleaning and CareIMPORTANT! COMPLETE DISINFECTION REQUIRES TWO DISTINCT STEPS

Remove residue with thorough and effective cleaning.

PREPARATION & CLEANINGa. Drain the bathing well of all water.b. Rotate the jet assembly to remove from jet case.c. Remove the magnetic impeller rotor from jet case.d. Disassemble the jet assemblies (2 pieces each) and place them in the sink. Use a non-

abrasive antibacterial cleaner to remove any visible residue. Rinse with fresh watere. Use a non-abrasive antibacterial cleaner to clean the bathing vessel, jet cases, drain

stopper and overflow mechanism. Rinse with fresh water.

REASSEMBLYa. Dry the jet assemblies and bathing vessel.

b. Reassemble and place jets in the 3 or 9 o’clock “RUN” position to operate.

WARNING: Do not release magnetic impeller rotor prior to seating properly into the jet case. SNAPPING INTO PLACE WILL CAUSE DAMAGE.

ADDITIONAL NOTES

• SANIJET Pipeless™ Hydromassage system cleaning and disinfection takes approximately 5 minutes when using Dispatch® Hospital Cleaner Disinfectant with Bleach.

• SANIJET’s Pipeless™ pedicure baths do not require a “fill and drain cycle” during disinfection, for improved water conservation.

• For applications requiring quick cleaning between treatments, we recommend a second set of “clean” jet assemblies for quick replacement.

IMP

OR

TA

NT • Always refer to your state and local guidelines for cleaning requirements.

• NEVER USE abrasive cleaners on any surface area.

• After each use, disinfect the system with the recommended disinfection procedures for maximum sanitation.

• BEFORE USE check the jet assembly is properly installed in the case motor assembly.

• BEFORE USE make sure that water is filled to at least 1” above the jets for proper operation.

• DO NOT attempt to activate the Pipeless™ Pedicure Bath without water present.

• TO RESET, unplug the system and wait 5 seconds, then plug back in.

Disinfection: Apply an EPA registered disinfectant, covering 100% of all surface areas for the required contact time, to kill bacteria, viruses and fungi.

RECOMMENDED CLEANER / DISINFECTANTSANIJET recommends the use of DISPATCH® Hospital Cleaner Disinfectant with Bleach - EPA Reg. No. 56392-7; EST. No. 62801-MI-001. Kills bacteria and viruses in 1 minute and tuberculosis in 30 seconds. Available in 32 oz trigger spray and 64 oz refill bottle.

DISINFECTIONa. Spray the surface area of the jet assemblies and bathing vessel until thoroughly

coated with an EPA–registered disinfectant.

b. Allow to set for the required disinfection contact period (refer to manufacturer’s specifications) then rinse surfaces with fresh water.

1) 2)

Page 14: PIPELESS™ PORTABLE FOOT BATH WITH SEAL-LESS JET … · WARNING: When using this unit, basic precautions should always be followed, including the following: 1. IMPORTANT: Read complete

11

Cleaning and Care Continued

WARNING: Do not release magnetic impeller rotor prior to seating properly into jet. SNAPPING INTO PLACE

WILL CAUSE DAMAGE.

WARNING: Do not place nail care products on the Pipeless™ Pedicure Bath

WARNING: Extended exposure to chemicals can damage the Pipeless™ Pedicure Bath basin, foot rest and/or

fabric. Failure to comply with these instructions can cause damage to the Pipeless™ Pedicure Bath

and void the warranty.

FOOT REST

•Cleanregularlywithsoapandwater

•Wipeupspillsassoonastheyoccur

•Liftmoststainswithanalcoholbasedcleaner

•Disinfectusinga5:1water/bleachsolution

•Thoroughlyrinseallcleaningsolutionresiduewithwater

•Airdry

Approved Cleaners: DISPATCH® Hospital Cleaner Disinfectant, Clorox® Disinfecting Wipes, LYSOL® Disinfectant,

Fantastik®

When using these cleaners, we strongly recommend rinsing the surface with clean water in order to remove

any cleaning residue.

HOW TO STORE THE FOOT BATH

1. Replace the jet assemblies into the jet casings by reversing the reassembly procedure shown on Page 10.

2. Store the power cord inside the recess cavity at the base of the foot bath.

3. Store the fill hose and Discharge Pump inside the tank or in another location.

4. Replace both lids.

5. Store away from direct exposure to sunlight to prevent discoloration of the foot bath.

Page 15: PIPELESS™ PORTABLE FOOT BATH WITH SEAL-LESS JET … · WARNING: When using this unit, basic precautions should always be followed, including the following: 1. IMPORTANT: Read complete

12

NO POWER / NOT OPERATING

1. Power Supply

Note: Recommended that all electrical service connections be made by a licensed electrician.

a. Ensure switch box power cord is properly plugged into an operational 115 VAC, 60 Hz GFCI power supply.

b. Check GFCI reset and circuit breakers for 115 V unit.

2. Dry Run Sensor Reset

Note: A dry run sensor automatically resets the Pipeless™ Pedicure Bath if no water is present or if unit had been

inadvertently turned or left on.

a. DO NOT OPERATE JET SYSTEM WITHOUT WATER FILLED AT LEAST 1 in (3 cm) ABOVE THE JETS.

b. Reset the motor by unplugging the system, waiting 5 seconds, then plugging system back in again.

3. Jet Assembly Alignment

a. Check jet assembly is locked in the 9 o’clock or 3 o’clock “run” position in the jet motor case.

b. Ensure magnetic impeller rotor is correctly installed in the jet motor case.

c. Inspect separator plate to ensure proper assembly in the jet escutcheon.

d. Inspect separator plate to ensure magnets (2) are present and properly installed.

EXCESSIVE NOISE

1. Remove jet assembly (escutcheon and separator plate) and inspect for dirt buildup, debris or damage.

Clean or replace if necessary.

2. Remove magnetic impeller rotor and inspect for dirt buildup or debris. Clean or replace if necessary.

3. Switch impeller rotor to other jet to test.

Note: Jet assembly must be reassembled and water refilled 1 in (3 cm) above jets for proper test.

4. If noise persists, contact your distributor for motor replacement information.

Troubleshooting

Page 16: PIPELESS™ PORTABLE FOOT BATH WITH SEAL-LESS JET … · WARNING: When using this unit, basic precautions should always be followed, including the following: 1. IMPORTANT: Read complete

120125

SANIJET® Customer Service Department

Toll Free: 877-934-0477 Toll Free Fax: 214-352-0348 E-mail: [email protected]

6200 Maple Avenue Dallas, Texas 75235 sanijet.com