PINE TREE LIMITED PARTNERSHIP - GezelmanPE · b7 b6 b5 b4 b3 b2 b1 b14 b13 b12 b19 d6 d5 ... i...
Transcript of PINE TREE LIMITED PARTNERSHIP - GezelmanPE · b7 b6 b5 b4 b3 b2 b1 b14 b13 b12 b19 d6 d5 ... i...
A4
1
A5
A6A7A8
A9
A1A20
A19
A18A17A10
A11
2ND FLOOR
A3 A2
A12
B10B9
B8A16A15
A14A13
B1B2
B3B4B5
B6B7
D14
D13
D12D11D10
D5D6B19
D16D15B12B13B14
D19
D20
D1D2D3
D4
C13
B20
D17D18
B11
D9
D8D7B18B17B16B15
C17
C16C15
C14C12C11C10
C18C19C20
C6C7C8C9
C1C2C3
C4C5
CB
1ST FLOOR
UTILITY
1
1
1 1
2
2
2
2
3
14
CONTRACTOR TO ADJUST WIRE RUNS AS NEEDED TO MATCH FIELD CONDITIONS. REF. TO MECHANICAL DRAWING FOR ARRAY ROOF LAYOUT.
ST
RG
. A
ST
RG
. B
ST
RG
. D
STRG. C
NEW COMPONENTS ON WALL
A20
INV 1
3
A19
INV 1
B20
INV 1
B19
INV 1
C20
INV 2
C19
INV 2
1
2 11
1
3
2
2
2
2
D20
INV 2
D19
INV 2
A1
B1
C1
D1
20
20
20
20
ON ROOF
ON EXT. WALL
T E S L A
10KWH
POWER PACK
STOREDGE STOREDGE
8" 8" 8"
AUTO
TRANSFORMER
AUTO
TRANSFORMER
8"
DC ACDC DC AC
LA
40
40
8
T E S L A
10KWH
POWER PACK
DC
8"
80 80
TO EXISTING
HOUSE METER,
LOAD SIDE
INV 1 INV 2
5
25
L1L2
25
L1L2
STRG A
STRG B
STRG C
STRG D
7
#6 GEC CONNECTED TO AC GROUNDING ELECTRODE
I MAX: 15 AMPS
V MAX: 500 V
I MAX: 15 AMPS
V MAX: 500 V
I MAX: 15 AMPS
V MAX: 500 V
I MAX: 15 AMPS
V MAX: 500 V
I MAX: 30 AMPS
V MAX: 500 V
INV. 1
ON
E
XT
. W
AL
L
I MAX: 30 AMPS
V MAX: 500 V
INV. 2
4
I MAX: 32 AMPS @ 240 V
I MAX: 32 AMPS @ 240 V
5
5
I MAX: 64 AMPS @ 240V
6
4
4
5
6 6
10
7
6
9
12
AC
AC
AC
AC AC13
8
8
I MAX:8.5 AMPS
V MAX:450 VOLT
I MAX:8.5 AMPS
V MAX:450 VOLT
I MAX: 25 AMPS @ 240 V
I MAX: 25 AMPS @ 240 V
1
EN
LA
RG
ED
V
IE
WIN
G &
H
YP
ER
LIN
KS
:
PR
IN
T V
ER
SIO
N O
F T
HIS
P
LA
N P
RO
VID
ES
M
IN
IM
UM
IN
FO
RM
AT
IO
N N
EE
DE
D B
Y U
SE
RS
.
EL
EC
TR
ON
IC
V
ER
SIO
N (E
V) P
RO
VID
ES
M
AG
NIF
IE
D V
IE
WIN
G U
P T
O 6
40
0%
. E
V A
LS
O P
RO
VID
ES
HY
PE
RL
IN
K A
CC
ES
S T
O O
EM
M
AN
UA
LS
A
ND
A
BU
ND
AN
T O
TH
ER
S
UP
PL
EM
EN
TA
RY
IN
FO
RM
AT
IO
N.E
V M
AY
B
E A
CC
ES
SE
D A
T:
WW
W.C
AD
VIC
E.U
S/S
OL
AR
.D
O/0
39
2P
.S
A.P
in
eT
re
e_
Mia
miB
ea
ch
_F
L.d
wg
SHEET NO:
PUBLISHED:
SHEET NAME:
DRAWN: CHECKED:SB AG
REVISIONS:
IN
ST
AL
LA
TIO
N O
F A
R
OO
F M
OU
NT
PIN
E T
RE
E L
IM
IT
ED
P
AR
TN
ER
SH
IP
60
00
P
IN
E T
RE
E D
RIV
E, M
IA
MI B
EA
CH
F
L 3
31
40
Siggi Brocks
CONTRACTOR:
□ COMPONENT SCHEDULE
1
SOLAR PHOTOVOLTAIC MODULE SOLAR WORLD SUNMODULE PLUS SW265 M FSEC # SW12-NT90-04082
MANUFACTURER PROVIDED MODULE JUNCTION BOX
3
COMBINER BOX NEMA 3R POS. FUSED 20 A
4
DC DISCONNECT SOLAR EDGE SE 7600A-USS INTEGRATED DISCONNECT
5
INVERTER SOLAR EDGE SE 7600A-USS RE: 0392PV20 FOR INV. INTERFACE
6
AUTO TRANSFORMER SOLAR EDGE SEAUTO TX5000
7
AC DISCONNECTMIN. 80 AMP/2P/ FUSED 80 AMP, 240V AC, SERVICE RATED HEAVY DUTY, NEMA 3
8
CIR PANEL (COLLECTION PANEL)
120/240/AC/1Ø 100 AMP MLO NEMA 3R
9
POINT OF CONNECTION LINE SIDE TAP 120/240/1Ø POLARIS TAP LOAD SIDE OF METER
10
OVER CURRENT PROTECTION DEVICE
(2) CIRCUIT BREAKER DPL 40 AMPS
11
POWER OPTIMIZER SOLAR EDGE P300 DC TO DC PWR OPTIMIZER
12
CRITICAL LOAD PANEL 120/240/AC/1Ø 100 AMP MLO NEMAR 3R
13
OVER CURRENT PROTECTION DEVICE
(2) CIRCUIT BREAKER DPL 25 AMPS
FED FROM STOREDGE RE: 0392PV20
○ WIRE SCHEDULE
1
PV SOURCE CIRCUIT
MNFC. PROVIDED CABLE ASSEMBLIES (+/-) EQUIPPED WITH MC4 LOCKING CONNECTORS
2
PV SOURCE CIRCUIT
HOME RUN #10 PV WIRE (+/-) EQUIPPED WITH MC4 LOCKING CONNECTORS & #8 GEC
3
GROUND EARTH CONDUCTOR #6 CU GROUND
4
PV OUTPUT CIRCUIT 4 - MIN. #8 THWN-2 & #8 GND IN MIN. 3/4" EMT OR 3/4" LFMC
5
INVERTER OUTPUT CIRCUIT 3 - #8 THWN-2 & #8 GND IN MIN. 3/4" EMT
6
SOLAR SYSTEM OUTPUT3 - # 4 THWN-2,& #4 GND IN MIN. 1" EMT OR RMC
7
GEC TO GROUND ELECTRODE #6 EXISTING
8
CRITICAL LOAD PANEL 3 - #10 THWN AND #8GND IN 3/4" EMT OR LMFC
APPLY TO COLLECTION PANEL & AC DISCONNECT:
WARNINGELECTRIC SHOCK HAZARD
DO NOT TOUCH TERMINALS.TERMINALS ON BOTH THE LINE AND LOAD SIDE
MAY BE ENERGIZED IN THE OPEN POSITION
APPLY TO DC DISCONNECT:
WARNINGELECTRIC SHOCK HAZARD.
THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED
PHENOLIC PLACARDS:
ELECTRICAL NOTES:1. ALL ASPECTS OF THE ELECTRICAL WORK REQUIRED TO COMPLETE THE PROJECT REPRESENTED IN THIS DOCUMENT SHALL COMPLY WITH
THE MANUFACTURER'S RECOMMENDATIONS/SPECIFICATIONS AND ALL CODES, STATUTES, AND STANDARDS ADOPTED BY THE STATE ANDTHE LOCAL AUTHORITY HAVING JURISDICTION.
2. THE INFORMATION PROVIDED IN THESE DOCUMENTS IS NOT EXHAUSTIVE. IT REMAINS THE CONTRACTORS RESPONSIBILITY TO ACHIEVE THEPROPOSED INSTALLATION IN FULL EXERCISE OF AND COMPLIANCE WITH THE ITEMS IDENTIFIED IN GENERAL ELECTRICAL NOTE 1.
3. EXPOSED PV SOURCE CIRCUT "A" AND "B" CROSSING ROOF AND CONTINUE VERTICAL TO 2ND FLOORROOF IN METAL RACEWAY.4. ALL UNIDENTIFIED CONDUCTORS UNDER MODULES ARE UL LISTED AND MANUFACTURER PROVIDED CABLES, CONNECTORS AND
ASSEMBLIES.5. ALL ELECTRICAL COMPONENTS, (RACEWAYS, JUNCTION BOXES, DISCONNECTS, PANEL BOARDS, ETC.), SHALL BE INSTALLED PLUMB, LEVEL,
AND IN COMPLIANCE WITH ALL APPLICABLE SECTIONS OF NEC ARTICLE 110.6. ALL RACEWAYS SHALL BE SUPPORTED ON INTERVALS AND BY METHODS AS APPROVED/REQUIRED BY THE CURRENTLY ADOPTED NEC ED.7. ALL RACEWAYS, CABLES AND J-BOXES SHALL BE LOCATED OUT OF DIRECT SUNLIGHT.8. SOLAR PANELS TO BE BONDED TO RACKING, UTILIZING WEEB OR SELF BONDING CLAMPING COMPONENTS.9. RACKING SYSTEM TO HAVE CONTINUOUS BONDING, WITH #6 GND.10. CONTRACTOR SHALL VERIFY THE INSTALLATION OF A BIDIRECTIONAL UTILITY SERVICE METER.11. NOT USED.12. THE CONTRACTOR SHALL SEAL ALL PENETRATIONS RESULTING FROM THIS SCOPE OF WORK.13. ALL SIGNAGE SHALL BE PROVIDED, AS REQUIRED BY THE CURRENTLY ADOPTED NEC ED.14. ALL RACEWAYS ON THE ROOF AND EXPOSED TO SUN LIGHT SHALL BE ELEVATED 8" ABOVE ROOF AND SUPPORTED IN COMPLIANCE WITH
NEC 358.30.15. CONTRACTOR TO MAINTAIN ORDERED CONDUCTOR PAIRS FROM STRING TO ASSIGNED CIRCUIT AS ASSIGNED ON HOME RUNS.
APPLY TO RACEWAYS & JUNCTION BOX:
WARNINGPHTOVOLTAIC POWER SOURCE
NEC 690.54 PERMANENT LABLE:APPLY TO AC DICONNECT & POINT OF INTERCONNECTION
PHOTOVOLTAIC POWER SOURCEAC OUTPUT CURRENT = 64 AMPAC OPERATING VOLTAGE = 240 VOLT
NEC 690.53 PERMANENT LABLE:APPLY TO INVERTER DC DISCONNECT: INVERTER 1 AND 2
WARNING, DC SHOCK HAZARD(1) MAXIMUM POWERPOINT CURRENT, Impp = 30 AMP(2) MAXIMUM POWERPOINT VOLTAGE, Vmpp = 400 VOLT(3) MAXIMUM SYSTEM VOLTAGE, Voc = 500 VOLT(4) MAXIMUM CIRCUIT CURRENT, Isc = 30 AMP
ALLEN GEZELMAN
16502 HANNA RD.
LUTZ, FLORIDA 33549
PH. 813 909 1956
Allen@Gezelman PE.COM
www.GezelmanPE.com
C
OP
Y R
IG
HT
&
IN
TE
LLE
CT
UA
L P
RO
PE
RT
Y N
OT
IC
E
T
HIS
P
LA
N S
ET
IS
C
OP
Y R
IG
HT
P
RO
TE
CT
ED
A
ND
C
ON
TA
IN
S IN
TE
LL
EC
TU
AL
P
RO
PE
RT
Y W
HIC
H B
EL
ON
GS
T
O A
LL
EN
G
EZ
EL
MA
N P
E.
A
CC
ES
S IS
G
IV
EN
T
O T
HE
IN
FO
RM
AT
IO
N H
ER
EO
N S
OL
EL
Y F
OR
T
HE
P
UR
PO
SE
O
F C
OM
PL
ET
IO
N O
F T
HE
P
RO
JE
CT
F
OR
W
HIC
H IT
IS
IN
TE
ND
ED
.
N
O O
TH
ER
U
SE
M
AY
B
E M
AD
E O
F T
HE
IN
FO
RM
AT
IO
N, D
RA
WIN
GS
, O
R ID
EA
S H
ER
EO
N W
IT
HO
UT
T
HE
E
XP
RE
SS
, W
RIT
TE
N, P
ER
MIS
SIO
N O
F A
LL
EN
G
EZ
EL
MA
N P
E
CON
TACT
DES
IGN
TEA
M @
Ge
ze
lm
an
PE
.com
SU
BJE
CT
T
O E
JC
DC
C
-7
00
:
HT
TP
://G
EZ
EL
MA
NP
E.C
OM
/R
EF
ER
EN
CE
/A
G/C
-7
00
.P
DF
473 Golden Isles Drive Suite 202
Hallandale Beach, FL 33009
Telephone: 877-678-6247
Fax: 954-200-6695
Email:
01
SCALE: NTS, REFER TO MECHANICAL DRAWINGS FOR ACTUAL ROOF PLAN
PV SOURCE CIRCUIT LAYOUT - 4 STRINGS, 80 PV MODULES
02
SCALE: NTS, REFER TO MECHANICAL DRAWINGS FOR ACTUAL ROOF PLAN
PV OUTPUT CIRCUIT, RE 01 FOR SOURCE CIRCUIT
EN
LA
RG
ED
V
IE
WIN
G &
H
YP
ER
LIN
KS
:
PR
IN
T V
ER
SIO
N O
F T
HIS
P
LA
N P
RO
VID
ES
M
IN
IM
UM
IN
FO
RM
AT
IO
N N
EE
DE
D B
Y U
SE
RS
.
EL
EC
TR
ON
IC
V
ER
SIO
N (E
V) P
RO
VID
ES
M
AG
NIF
IE
D V
IE
WIN
G U
P T
O 6
40
0%
. E
V A
LS
O P
RO
VID
ES
HY
PE
RL
IN
K A
CC
ES
S T
O O
EM
M
AN
UA
LS
A
ND
A
BU
ND
AN
T O
TH
ER
S
UP
PL
EM
EN
TA
RY
IN
FO
RM
AT
IO
N.E
V M
AY
B
E A
CC
ES
SE
D A
T:
WW
W.C
AD
VIC
E.U
S/S
OL
AR
.D
O/0
39
2P
.S
A.P
in
eT
re
e_
Mia
miB
ea
ch
_F
L.d
wg
SHEET NO:
PUBLISHED:
SHEET NAME:
DRAWN: CHECKED:SB AG
REVISIONS:
IN
ST
AL
LA
TIO
N O
F A
R
OO
F M
OU
NT
PIN
E T
RE
E L
IM
IT
ED
P
AR
TN
ER
SH
IP
60
00
P
IN
E T
RE
E D
RIV
E, M
IA
MI B
EA
CH
F
L 3
31
40
Siggi Brocks
CONTRACTOR:
ALLEN GEZELMAN
16502 HANNA RD.
LUTZ, FLORIDA 33549
PH. 813 909 1956
Allen@Gezelman PE.COM
www.GezelmanPE.com
C
OP
Y R
IG
HT
&
IN
TE
LLE
CT
UA
L P
RO
PE
RT
Y N
OT
IC
E
T
HIS
P
LA
N S
ET
IS
C
OP
Y R
IG
HT
P
RO
TE
CT
ED
A
ND
C
ON
TA
IN
S IN
TE
LL
EC
TU
AL
P
RO
PE
RT
Y W
HIC
H B
EL
ON
GS
T
O A
LL
EN
G
EZ
EL
MA
N P
E.
A
CC
ES
S IS
G
IV
EN
T
O T
HE
IN
FO
RM
AT
IO
N H
ER
EO
N S
OL
EL
Y F
OR
T
HE
P
UR
PO
SE
O
F C
OM
PL
ET
IO
N O
F T
HE
P
RO
JE
CT
F
OR
W
HIC
H IT
IS
IN
TE
ND
ED
.
N
O O
TH
ER
U
SE
M
AY
B
E M
AD
E O
F T
HE
IN
FO
RM
AT
IO
N, D
RA
WIN
GS
, O
R ID
EA
S H
ER
EO
N W
IT
HO
UT
T
HE
E
XP
RE
SS
, W
RIT
TE
N, P
ER
MIS
SIO
N O
F A
LL
EN
G
EZ
EL
MA
N P
E
CON
TACT
DES
IGN
TEA
M @
Ge
ze
lm
an
PE
.com
SU
BJE
CT
T
O E
JC
DC
C
-7
00
:
HT
TP
://G
EZ
EL
MA
NP
E.C
OM
/R
EF
ER
EN
CE
/A
G/C
-7
00
.P
DF
473 Golden Isles Drive Suite 202
Hallandale Beach, FL 33009
Telephone: 877-678-6247
Fax: 954-200-6695
Email:
32'
6' E-W Z RAILPAIRS (ZR)
PV MODULE
E-W 8" HZB
6' VCS
REARPARAPET
N-S 8" SLOPING ZEE (SZB)
E-W 8" HZB5°+
VCS: VERTICAL CEE SUPPORTHZB: HORIZONTAL ZEE BEAMSZB: SLOPING ZEE BEAMZR : ZEE RAIL
6' C-C BOLT SPACING. MINIMUM3-1/2 " Ø BOLTS, 3" INTO CONCRETE
TOP OF ROOF EXTERIOR WALKWAY
TOP OF PARAPET
43"
5'±
6' VCS
16''
2'±
4'
6' VCS
6' VCS6' VCS
8'c-c
8'c-c
8'c-c
18'
16'
14'
16'
19'4'
8'
43'
16'
6'
7'
13'
5'
ELEC. SVC. ENTRANCE
2-STOREDGE POWERWALL& BATTERIES
12'-6"12'-6"
8'
VCS
ABSA
VCS AT EACHEND OF ZHB
HZB
SZB
2'
02
03
I CERTIFY THAT PV INSTALLATIONS MADE IAW THIS PLAN CAN RESIST POSITIVE AND NEGATIVE WIND FORCES PREDICTED IAWASCE 7. THIS IS ATTESTED TO BY MY SIGNATURE AND SEAL ON THIS DRAWING AT THE UPPER RIGHT.
SCALE:NTS
SCALE:NTS
2014 FBC ( 5TH EDITION FLORIDA BUILDING CODE)
05SCALE: 1" : 4'-11"
PLAN VIEW
04SCALE: NTS
ELEVATION VIEW
SITE
60
00
Pin
e T
ree
Dri
ve
Mia
mi
Be
ac
h
INSTALLATION NOTES: COMBINED PLAN CONSISTING OF STRUCTURAL & ELECTRICAL PLAN SHEETS
1. THIS NOTE SECTION DEALS WITH STRUCTURAL ELEMENTS OF PLAN.2. ELECTRICAL NOTES ARE ON RESPECTIVE PLAN SHEETS.3. GROSS AREA OF UPPER ROOF SYSTEM INCLUDING WALKWAYS IS 2820-SF, SOLAR COVERS 920-SF.4. GROSS AREA OF LOWER ROOF IS 1593-SF, SOLAR COVERS 550 SF5. PV MODULE HAS A 113-PSF PRESSURE RATING.6. 39-INCH WIDE ROOF PERIMETER WALKWAYS, 9-INCH THICK PARAPET WALLS, & HEIGHT OF REAR
OF ARRAYS (NORTH ENDS) ARE DEEMED ADEQUATE TO PROVIDE PRESSURE ZONE 1 SET-BACK PERASCE 7 & FIRE ACCESS PER NFPA 1.
7. PV RACK SYSTEM DESCRIPTION BEGINNING UPWARD FROM 9-INCH THICK SOLID CONCRETEPARAPET WALLS:
a. FOLLOWING DESCRIBED FRAMING MEMBERS SHALL BE GALVALUME-COATED, MINIMUM14-GAUGE, COLD-FORMED, STEEL. SHAPE & MINIMUM LONG CROSS SECTION DIMENSIONSHALL BE AS SHOWN IN DRAWINGS.
b. VCS (VERTICAL CEE SUPPORTS) SHOWN IN DRAWINGS SHALL EACH BE ATTACHED TO OUTSIDEOF PARAPET WALL BY MINIMUM THREE ½-INCH DIAMETER X 3-INCH LONG CRS (CORROSIONRESISTANT STEEL) BOLTS WITH MINIMUM 6-INCH C-C (CENTER TO CENTER) VERTICALSPACING.
c. BOLTS SHALL BE SET INTO POWERS OR EQUAL DROPIN ANCHORS INSTALLED INTO PARAPETSIAW (IN ACCORDANCE WITH) OEM (ORIGINAL EQUIPMENT MANUFACTURER) INSTRUCTIONShttp://www.powers.com/product_06308.php
d.HZB (HORIZONTAL ZEE BEAMS) SHALL RUN EAST-WEST & SHALL ATTACH TO VCS EACH END BYMINIMUM OF TWO ½-INCH DIAMETER CRS BOLTS.
e. CONTRACTOR SHALL ADJUST FRAMING IN ORDER THAT THE HZB &ZR MEMBERS DO NOT HOLDWATER BY ESTABLISHING A SLIGHT POSITIVE BUBBLE LEVEL TO WEST.
f. SZB (SLOPING ZEE BEAMS) SHALL RUN NORTH-SOUTH RESTING UPON & ATTACHED TO HZB BYSIX (THREE INTO EACH), MINIMUM #12, 1-INCH LONG, SS, TEK SCREWS THRU 2-INCH X 2-INCH,MINIMUM LENGTH SIX INCH, ANGLE.
g. ZR (ZEE RAILS) SHALL RUN EAST WEST PERPENDICULAR TO & ON TOP OF SZB. SZB-ZR ATTACHSAME AS E ABOVE.
h. PV MODULES SHALL REST UPON & ATTACH TO ZR USING GROUNDING MID CLAMPS,STANDARD END CLAMPS, & 3-INCH LONG X #12 SS TEK SCREWS.
i. GEZELMAN PROPRIETARY ABSAS (ADHERED BALLAST SOLAR ATTACHMENT SYSTEM) SHALL BEUSED ON SLOPING ROOF PLANES AS SHOWN IN DRAWING FIGURES TO PROVIDESUPPLEMENTAL/REDUNDANT VERTICAL SUPPORT & UPLIFT RESISTANCE-DETAILS ARE SHOWNIN DRAWING FIGURES. TESTING UNDER EOR (ENGINEER OF RECORD) SUPERVISON IN FACTORY& FIELD SITUATIONS HAS ESTABLISHED 900-POUNDS ALLOWABLE PER SINGLE ABSASATTACHMENT.
8. CONTRACTOR SHALL PROVIDE SUCH ADDITIONAL STRUCTURAL & ELECTRICAL INFORMATION ASAHJ (AUTHIORITY HAVING JURISDICTION AKA BUILDING DEPARTMENT) MAY REQUIRE.
9. EOR PREFERS EMAIL [email protected]
STEEL SCHEDULE
RESIDENTIAL PV INSTALLATIONMiami-Dade FOLIO: 02-3211-014-0590
CONTRACTOR:
473 GOLDEN ISLES DRIVE SUITE 202
HALLANDALE BEACH, FL 33009
Telephone: 877-678-6247
Fax: 954-200-6695
Email: [email protected]
LAYOUT DETAILING
BALLAST,4X4 PLATESREWS,CARRIAGEBOLT ADHERING
NAME ABBREV./SYMBOL FULL NAME CROSS SECTION LONG DIMENSION
CA CONNECTION ANGLE 2-INCHES
HZB HORIZONTAL ZEE BEAM 8-INCHES
SZB SLOPING ZEE BEAM 8-INCHES
VCS VERTICAL CEE SUPPORT 8-INCHES
ZR ZEE RAIL 6-INCHES
Vult175/Vasd135.6-MPH, RISK II, EXP. C , UPLIFT: PZ1-37.6, PZ2-WIDTH 3-FT;INSTALLATION ENTIRELY WITHIN PZ1. GROSS FORCES: SLIDING<4000LBS.OVERTURNING <14000FT-LB, UPLIFT <35000LBS
WIDTH=39.1"
PROJECTED
HEIGHT=64.32"
9 8 7 6 5 4 3 2 1
9 8 7 6 5 4 3 2 1
A
B
C
D
E
F
A
B
C
D
E
F
CO
PYR
IGH
T &
INTE
LLEC
TUA
L P
RO
PER
TY N
OTI
CE
·TH
IS P
LAN
SE
T IS
CO
PYR
IGH
T P
RO
TE
CTE
D A
ND
CO
NTA
INS
INTE
LLE
CTU
AL
PR
OP
ERTY
WH
ICH
BEL
ON
GS
TO A
LLEN
GEZ
ELM
AN
PE.
·A
CC
ESS
IS G
IVE
N T
O T
HE
INFO
RM
ATI
ON
HE
RE
ON
SO
LELY
FO
R T
HE
PU
RP
OSE
OF
CO
MP
LETI
ON
OF
THE
PR
OJE
CT
FOR
WH
ICH
IT IS
INTE
ND
ED.
·N
O O
TH
ER
USE
MA
Y B
E M
AD
E O
F T
HE
INFO
RM
ATI
ON
, DR
AW
ING
S, O
R ID
EA
S W
ITH
OU
T T
HE
EX
PR
ESS,
WR
ITTE
N P
ERM
ISSI
ON
OF
ALL
EN G
EZEL
MA
N P
E. ENGINEER
ALLEN GEZELMAN16502 HANNA RD.LUTZ, FLORIDA 33549
PH.813 909 1956
PE 59180
VOID WITHOUT
VO
ID W
ITH
OU
T
RA
ISE
D O
R E
LE
CT
RO
NIC
SE
AL
RAISED OR ELECTRONIC SEAL
DRAFTSMAN:
ALPER [email protected]
SCOPE OF WORK:EN
LAR
GED
VIE
WIN
G &
HYP
ERLI
NK
S:P
RIN
T V
ERSI
ON
OF
THIS
PLA
N P
RO
VID
ES IN
FOR
MA
TIO
N N
EED
ED B
Y U
SER
S.EL
ECTR
ON
IC V
ERSI
ON
PR
OV
IDES
VIE
WIN
G U
P T
O 6
400%
.C
ON
TAC
T D
ESIG
N T
EAM
@ w
ww
.Gez
elm
anP
E.co
m
SUB
JEC
T TO
EJC
DC
C-7
00
htt
p:/
/ge
zelm
anp
e.c
om
/REF
EREN
CE/
AG
/C-7
00
.PD
F
01SCALE:NTS
ENGINEERING NOTES.
WIND
AXITEC AC-260P
6' E-W Z RAIL (ZR)PV MODULE
RIDGE
5°
TOP OF PARAPET
5'+
19"
ABSA
10" VCS
N-S10" SZB
4' - 4" CEE BRACE
8' 8' 6'
1'-412"
4'
12"
21'
8'
25'
12'
20'
10'
8'
43'
16'
13'
12'12'1'-4"
8'
8'
6'
33'
VCSABSA ZR
VCS
6' C-C BOLT SPACING. MINIMUM3-1/2 " Ø BOLTS, 3" INTO CONCRETE
PV MODULE6' E-W Z RAIL (ZR)
4" CEE BRACE
12"
12' 12' 1.5'
TOP OF PARAPET
9 8 7 6 5 4 3 2 1
9 8 7 6 5 4 3 2 1
A
B
C
D
E
F
A
B
C
D
E
F
CO
PYR
IGH
T &
INTE
LLEC
TUA
L P
RO
PER
TY N
OTI
CE
·TH
IS P
LAN
SE
T IS
CO
PYR
IGH
T P
RO
TE
CTE
D A
ND
CO
NTA
INS
INTE
LLE
CTU
AL
PR
OP
ERTY
WH
ICH
BEL
ON
GS
TO A
LLEN
GEZ
ELM
AN
PE.
·A
CC
ESS
IS G
IVE
N T
O T
HE
INFO
RM
ATI
ON
HE
RE
ON
SO
LELY
FO
R T
HE
PU
RP
OSE
OF
CO
MP
LETI
ON
OF
THE
PR
OJE
CT
FOR
WH
ICH
IT IS
INTE
ND
ED.
·N
O O
TH
ER
USE
MA
Y B
E M
AD
E O
F T
HE
INFO
RM
ATI
ON
, DR
AW
ING
S, O
R ID
EA
S W
ITH
OU
T T
HE
EX
PR
ESS,
WR
ITTE
N P
ERM
ISSI
ON
OF
ALL
EN G
EZEL
MA
N P
E.
ENLA
RG
ED V
IEW
ING
& H
YPER
LIN
KS:
PR
INT
VER
SIO
N O
F TH
IS P
LAN
PR
OV
IDES
INFO
RM
ATI
ON
NEE
DED
BY
USE
RS.
ELEC
TRO
NIC
VER
SIO
N P
RO
VID
ES V
IEW
ING
UP
TO
640
0%.
SUB
JEC
T TO
EJC
DC
C-7
00
htt
p:/
/ge
zelm
anp
e.c
om
/REF
EREN
CE/
AG
/C-7
00
.PD
FC
ON
TAC
T D
ESIG
N T
EAM
@ w
ww
.Gez
elm
anP
E.co
mENGINEER
ALLEN GEZELMAN16502 HANNA RD.LUTZ, FLORIDA 33549
PH.813 909 1956
PE 59180
VOID WITHOUT
VO
ID W
ITH
OU
T
RAISED OR ELECTRONIC SEAL
DRAFTSMAN:
ALPER [email protected]
02PLAN VIEW
01SCALE: NTS
ELEVATION VIEW
03REAR ELEVATION
60
00
Pin
e T
ree
Dri
ve
Mia
mi
Be
ac
h
CONTRACTOR:
473 GOLDEN ISLES DRIVE SUITE 202
HALLANDALE BEACH, FL 33009
Telephone: 877-678-6247
Fax: 954-200-6695
Email: [email protected]
SCALE: 1" = 3' - 6"
SCALE: NTS