Pilot Controlled Check Valves - anhussunally.com€¦ · Pilot Controlled Check Valves DIRECTIONAL...

3
Internal Drain Type External Drain Type Pilot Controlled Check Valves DIRECTIONAL CONTROLS Pilot Controlled Check Valves These check valves allow flow in one direction and prevent flow in the reverse direction, until operated by pilot pressure to allow free reverse flow. The specified cracking pressure is required to open the valve to allow free flow direction. Specifications Model Number Designation Model Numbers Rated Flow * L/Min. Max. Operating Pres. Kgf/cm 2 Cracking Pres. Kgf/cm 2 Mass Kg Sub-plate Mounting CP G-06- - -20 125 250 0.35, 2 3.5, 5 7 * Rated flow is the approximate flow rate, when there is a free flow pressure drop of maximum 3 Kgf/cm 2 the fluid has a specific gravity of 0.85, kinematic viscosity of 20cSt, and the cracking pressure is 0.4 Kgf/cm 2 . F- CP G 06 -E -30 -20 Series Number Type of Connection Type of Connection Valve Size Drain Connection Cracking Pres. Kgf/cm 2 Design Number F: Special seals for phosphate ester type fluid (Omit if not required) CP: Pilot Controlled Check Valve CPD: Decompression Type Pilot Controlled Check Valve G: Sub-plate Mounting 06 None: Internal Drain E: External Drain 5 : 0.35 30 : 2.0 50 : 3.5 75 : 5.0 20 Mounting Bolts Valve Model Numbers Socket head Cap screw Qty. Bolt Kit Model Number CP -G-06 M10 x 80 Lg. 4 BKHCG-06-20 Sub-plates Valve Model Numbers Sub-plate Model Numbers Thread Size Approx. Mass Kg. CP G-06 HGM-06-2080 3/4 BSP.F 2.4 HGM-06X-2080 1 BSP.F 3.0 Sub-plates are available, specify sub-plate model from the table above. When sub-plates are used, the mounting surface should have a good machined finish. Instructions Operation of internal drain and external drain types When the outlet side P1 is directly connected to the tank in reversed free flow (Fig. a), internal drain type is normally used. When the back pressure is applied to the outlet side P1 (Fig. b), be sure to use external drain type. Minimum pilot pressure characteristics That depends on the pressure of inlet side in the reversed free flow. This value can be determined from the characteristics chart. (a) (b) P2 P1 DR P2 P1 Graphic Symbol EIC-E-1008-0 Pilot Controlled Check Valves 413 E

Transcript of Pilot Controlled Check Valves - anhussunally.com€¦ · Pilot Controlled Check Valves DIRECTIONAL...

Page 1: Pilot Controlled Check Valves - anhussunally.com€¦ · Pilot Controlled Check Valves DIRECTIONAL CONTROLS Pilot Controlled Check Valves These check valves allow flow in one direction

Internal Drain Type External Drain Type

Pilot Controlled Check Valves

DIRECTIONAL CONTROLS

■ Pilot Controlled Check ValvesThese check valves allow flow in one direction

and prevent flow in the reverse direction, until

operated by pilot pressure to allow free reverse

flow. The specified cracking pressure is

required to open the valve to allow free flow

direction.

■ Specifications

■ Model Number Designation

Model Numbers Rated Flow *

L/Min.

Max. Operating Pres.

Kgf/cm2

Cracking Pres.

Kgf/cm2

Mass

Kg

Sub-plate Mounting CP※G-06-※-※-20 125 250 0.35, 2

3.5, 5 7

* Rated flow is the approximate flow rate, when there is a free flow pressure drop of maximum 3 Kgf/cm2

the

fluid has a specific gravity of 0.85, kinematic viscosity of 20cSt, and the cracking pressure is 0.4 Kgf/cm2.

F- CP G 06 -E -30 -20

Series

Number

Type of

Connection

Type of

Connection

Valve

Size

Drain

Connection

Cracking Pres.

Kgf/cm2

Design

Number

F:

Special seals for

phosphate ester

type fluid (Omit

if not required)

CP:

Pilot Controlled

Check Valve

CPD:

Decompression

Type Pilot

Controlled

Check Valve

G:

Sub-plate

Mounting

06

None:

Internal

Drain

E:

External

Drain

5 : 0.35

30 : 2.0

50 : 3.5

75 : 5.0

20

■ Mounting Bolts

Valve

Model Numbers

Socket head

Cap screw Qty.

Bolt Kit

Model

Number

CP※-G-06 M10 x 80 Lg. 4 BKHCG-06-20

■ Sub-plates

Valve

Model

Numbers

Sub-plate

Model

Numbers

Thread

Size

Approx.

Mass

Kg.

CP※G-06 HGM-06-2080 3/4 BSP.F 2.4

HGM-06X-2080 1 BSP.F 3.0

Sub-plates are available, specify sub-plate model from the table above. When sub-plates are used, the

mounting surface should have a good machined finish.

■ Instructions

Operation of internal drain and external drain types

When the outlet side P1 is directly connected to the tank in

reversed free flow (Fig. a), internal drain type is normally

used. When the back pressure is applied to the outlet side P1

(Fig. b), be sure to use external drain type.

Minimum pilot pressure characteristics

That depends on the pressure of inlet side in the reversed free

flow. This value can be determined from the characteristics

chart.

(a) (b)

P2

P1

DRP2

P1

Graphic Symbol

EIC-E-1008-0

Pilot Controlled

Check

Valves

413

E

Page 2: Pilot Controlled Check Valves - anhussunally.com€¦ · Pilot Controlled Check Valves DIRECTIONAL CONTROLS Pilot Controlled Check Valves These check valves allow flow in one direction

Pilot Controlled Check Valves

DIRECTIONAL CONTROLS

11.351

79.4

168

54

102

Free Flow Outlet or

Reversed controlled

Flow Inlet Port

Drain Port

Free Flow Inlet or

Reversed controlled

Flow Outlet Port

Pilot Port

11 Dia. x Thru.

17.5 Dia. Spotface

4 Places

40

6

69

80

Locating Pin

6 Dia.

Mounting Surface

(O-Ring Furnished)

CPG

CPDG

16

G

11

.1 20.6

39

.7

44.5

49

.2 60

.3

93

16

.4

6.4

39.7

73

F

22E

D

104

C

B

11.3 79.4

102

M10 Thd. x 20 Deep

4 Places

8.8 Dia. x Thru.

14 Dia. Spotface

4 Places

'A' BSP.F Thd.

2 Places (From Rear)

7 Dia. x 10 Deep

22 Dia. 2 Places5 Dia. x Thru.

1/4 BSP.F Thd.

2 Places

(From Rear)

Plug the drain port

for the valve of

internal drain type.

06

06X

Sub-plate

Model Numbers A B C D E F G

Mass

(Approx.) Kg.

HGM-06-2080 3/4 124 10 77 27 73 36 2.4

HGM-06X-2080 1 136 16 80 24 75 45 3

Mounting sub-plate are available on requests. Specify sub-plate model

number from above table. When sub-plates are not used, mounting

surface as shown by shaded area must be finished flat and smooth.

-06- - -20

Sub-plate: HGM- -2080

DIMENSIONS IN

MILLIMETRES

414

Page 3: Pilot Controlled Check Valves - anhussunally.com€¦ · Pilot Controlled Check Valves DIRECTIONAL CONTROLS Pilot Controlled Check Valves These check valves allow flow in one direction

Pilot Controlled Check Valves

DIRECTIONAL CONTROLS

■ Spare Parts List

List of Seals

Sl.

No. Name of part Part No. Qty

1 O – Ring SO-NB-P8 1

2 O – Ring SO-NB-P9 2

3 O – Ring SO-NB-P28 2

4 O – Ring SO-NB-G35 2

5 O – Ring SO-NA-P22A 1

6 Backup Ring SO-BB-P22A 2

Note : When ordering the seals,

please specify the seal kit number KS-CP※G-06-20

Pressure Drop for Free FlowPressure Drop for Reversed

Controlled Flow.

Pilot Pressure Chart

Pressure Drop For Reversed Controlled Flow

Only When Decompression Valve is Opened

0

50

100

Pre

ssure

Dro

p 150

200

20 40 60 80 100 L/min

Flow

Kgf/cm² Oil Viscosity ---32cSt

Pilot Controlled

Check

Valves

415

E

50 100 150 200 L/min.

Flow

0

4

8

12

Kgf/cm²

Pre

ssu

re D

rop

Oil Viscosity ---32cSt

0

1

2

3

50 100 150 200 L/min.

Flow

Kgf/cm² Oil Viscosity ---32cSt

MIN. PILOT PRESSURE TO OPEN THE DECOMPRESSION VALVE

TYPE "CPG" TYPE "CPDG"

TYPE "CPDG"

0

20

40

60

80

100

120

Kgf/cm²

50 100 150 200 250 Kgf/cm²

Min

imum

Pil

ot

Pre

ssure

(P

P)

Supply Pressure (P2)

P2

P1

PP

P2

P1

PP

P2

P1

PP

CP G-06- -50

Cracking Pressure

5 Kgf/cm²

Cracking Pressure

0.35 Kgf/cm²

Cracking Pressure

5 Kgf/cm²

Cracking Pressure

0.35 Kgf/cm²