Pilecap Design
description
Transcript of Pilecap Design
Sheet1KUMPULAN JURUTERA PERUNDINGProject title:INTANA RIA 3Sheet No:239 A-C Jalan Bandar 13, Melawati MetroJob No.Ulu Klang 53100 Kuala LumpurPart of structure :PILECAPDesigned byKongDate:PILECAP MARKING2PDesign dataColumn loading (Ns)=500kNUltimate column load (Nu = 1.5 x Ns)=750kNPile size (square or circular)=150mmColumn dimension A=225mmColumn dimension B=225mmSize of pile cap X=910mmSize of pile cap Y=600mmDepth of pilecap=525mmConcrete cover=150mmConcrete grade (fcu)=25N/mm2Steel grade (fy)=460N/mm3Unfactored load per pile (S.L.)=250kNFactored load per pile (U.L)=375kNNo of piles in group=2nos.Spacing x from c.g.=225mmSpacing y from c.g.=0mmS of distance from column face x-x=0.11mS of distance from column face y-y=0mNos of piles along axis X-X=1Nos of piles along axis Y-Y=0Checking Bending MomentMoment Mxx=41.25kNmd = D - c - f/2=365mmk = M/bd2fcu=0.0206< 0.156z = lever arm=346.75mmAst = M / 0.87 fy z=297mm2Nominal steel 0.13%bh=410mm2Ast required=410mm2Use4T12Ast provided =452mm2spacing =163mm c/cMoment Myy=0.00kNmd = D - c - f - f/2=345mmk = M/bd2fcu=0.0000< 0.156z = lever arm=327.75mmAst = M / 0.87 fy z=0mm2Nominal steel 0.13%bh=621mm2Ast required=621mm2Use6T12Ast provided =679mm2spacing =160mm c/cChecking normal shearAssume critical section occur at distance "av"measured at face of column (Axis x-x and y-y)Axis x-xAxis y-y100 Asprov / bd=0.210.22vc = 0.79(100As/bd)1/3(400/d)1/4/1.25=0.380.39N/mm2v = V/bd=1.710.00N/mm2av=67.501.00mmEnchanced shear = 2d x vc / av=4.13287.31Shear is ok.Shear is ok.Checking punching shearCritical perimeter (from face of col)=900mmCritical punching shear area=328,500mm2Punching shear stress = force/area=2.28