Pi Flowsic100 Flare en v2!0!2012-06 Web

4
PRODUCT INFORMATION FLOWSIC100 Flare Gas massflow measuring device Gas Mass Flow Measurement for Flare Gas Applications

description

Debitmetre pentru facla. Sisteme ultrasonice.

Transcript of Pi Flowsic100 Flare en v2!0!2012-06 Web

Page 1: Pi Flowsic100 Flare en v2!0!2012-06 Web

Pr

od

uc

t In

fo

rm

atI

on

fLoWSIc100 flareGas massflow measuring device

Gas Mass Flow Measurement for Flare Gas Applications

Page 2: Pi Flowsic100 Flare en v2!0!2012-06 Web

2 F L O W S I C 1 0 0 F L a r e | S I C K 2 0 1 2 - 0 6Subject to change without notice

FLOWSIC100 Flare –The reliable mass flow measurement for flare and vent gas applications

• Cross-duct high speed version (patent pending)

• 90° nozzle installation

• Retractable under process conditions

• Hermetically sealed stainless steel and titanium probes

• ATEX, IECEx and CSA approved for use in explosive hazardous areas

• Cross-duct high speed version for large ducts and signal damping gases (patent pending)

• Retractable under process conditions

• Hermetically sealed stainless steel and titanium probes

• ATEX, IECEx and CSA approved for use in explosive hazardous areas

• High speed probe version (patent pending)

• Singleflangeinstallation

• Retractable under process conditions

• Hermetically sealed titanium probe

• ATEX, IECEx and CSA approved for use in explosive hazardous areas

K e Y F e aT U r e S

F L O W S I C 1 0 0 e X - S F L O W S I C 1 0 0 e X / e X - r e F L O W S I C 1 0 0 e X - P r

a r e a S O F a P P L I C aT I O N

• CO2 emission monitoring for compliance with government regulations

• Valveleakagedetectionandgasidentification

• Optimizationofsteamusageinflaregassystems

• Gas wastage reduction

• Accurate mass balance calculations and process optimization

• Innovative high speed sensor design – operation under very high gas velocities

• High resolution resulting in accurate measurement near tozeroflowreadings

• Field repeatable check procedure of factory zeroflowtest.

• Remote installation of control unit up to 1,000 m (serial interconnection)

• Single nozzle installation using probe version FLOWSIC100 EX-PR

• Improved accuracy – spool piece solution

• Assured and reliable device function – automatic self-diagnosis by integrated check cycle

• Singlepathandmultipathconfiguration(1-,2path,3x1path)

FLOWSIC100 EX-S retractable (measuring position)

FLOWSIC100 EX-PR Probe version

Page 3: Pi Flowsic100 Flare en v2!0!2012-06 Web

3S I c K | f L o W S I c 1 0 0 f L a r e

POWER

FAILURE

MAINTENANCEREQUEST

S t atus: Measur i n g

Statu s Ac k M en u

2 0 1 2 - 0 6Subject to change without notice

u n I Q u e H I G H S P e e d S e n S o r d e S I G n ( Pat e n t P e n d I n G )

For the FLOWSIC100 Flare an innovative sensordesignwasdeveloped.Theultra-sonictransducerisembeddedinaflowopti-mizedsensorshape–specialqualifiedforhighspeedgasflowconditions.Theuniquedesignreducesflownoiseandsignaldrifttoa minimum and enables stable and reliable measurement results at very high gas veloci-ties.Aoptimized 2-stage signal algorithm ensuresbestsignalprocessingunderlowflowaswellasandunderhighflowconditions.

P r o d u c t d e S c r I P t I o n

Undisturbed, constant signal dispersion, no turbulences

Turbulences, signal disturbed

High speed sensorConventional sensor

Embedded ultrasonic transducer

a

Gas duct

Flow direction

SR unit FLSE100-EXS

SR unitFLSE100-EXS

Hazardous area Safe area

MCUP control unit (process version)

Cable length: up to 1,000 m

Optional components

• MCUP control unit for use in Ex zone 1+2(ATEXcertification)andClI,Div2/Zone 2

• Spool piece version also complete with p and T transmitters

The FLOWSIC100 Flare standard version contains two FLSE100 sender/receiver units (SR units) and aMCUPcontrolunit(processversion).TheMCUPis used for signal inputs/outputs, determining ref-erence values (standardization) as well as calcu-latingmolecularweight,massfloworstorageofgasvolume.OptionallytheMCUPisapplicableinhazardousareas.TheSOPASsoftwareprovidesaccess to all parameters and contains graphical display of measured values, trend curves and stores all parameter changes and measure-menteventsinanintegratedlogbook.

Installation of the sender/receiver units

• Cross-duct installation: two sender/receiver units are mounted on both sides of a duct – rectangular to the gas flowdirection(typeFLSE100 EX-S).

• One-side installation: Only one single sender/receiver unit (probe version) is mountedataspecificangletothegasflow.Both ultrasonic transducers are installed on theprobewithafixedmeasuringpath.Nospecificalignmentbetweenultrasonictrans-ducersneeded.

Perpendi-cular nozzle installation

Page 4: Pi Flowsic100 Flare en v2!0!2012-06 Web

8011

249/

2012

-06

· PrintedinGermany∙Subjecttochangewithoutnotice.

Technical Data fLoWSIc100 flare

Version eX-S eX/eX-re eX-Pr

Measuring parameter

Measuring principle Ultrasonic transit time measurement method

Measuring values Massflow,standardandactualvolumetricflow,molecularweight,totalizedstandardvolumeandmass, gas velocity, gas temperature, speed of sound

Measuring range 1) 0.03upto120m/s 0.03upto90m/s

Accuracy2)3) 1-pathmeasurement:±1.5...5.0%/±0.5%4);2-pathmeasurement:±1.0...3.0%/±0.5%4)

Accuracy of molecular weight5) <2%ofmeasuredvalue,2...120kg/kmol

Accuracyofmassflow5) 1-pathmeasurement:±2.5...5%ofmeas.value;2-pathmeasurement:±2...4%ofmeas.value

Resolution 0.001m/s

Repeatability 0.2%at10m/s

Rangeability Up to 4000 : 1

Inner duct diameter (pipe size) 0.1...0.6m(≥4...24in) 0.2...1.8m(8...72in) 0.3...1.8m(12...72in)

Measurement conditions

Gas temperature • Standardrange: –70...+180°C(–95...356°F)• Hightemperaturerangezone1: –70...+280°C(–95...535°F) zone2: –70...+260°C(–95...500°F)

• Lowtemperaturerange: –196...+100°C(–325...210°F)

Pressure range –0.5…16barg;20bargmax.onrequest

Ambient conditions

Temperature range •Sender/receiverunits: –40...+70°C(–40...158°F);Optional:–50...+70°C(–58...158°F)•MCUPcontrolunit: –40...+60°C(–40...140°F)

Approval

Ex-certification SRunit,zone1 • ATEX II 1/2G Ex d [ia] IIC T4• ATEX II 1/2G Ex de [ia] IIC T4• IECEx Ex d [ia] IIC T4•CSA CI I, Div1 group B, C, D•CSA CI I, Div2 group A, B, C, D•CSA CI I, zone1/zone2 IIC T4Option:Temp.classT6

• ATEX II 2 G Ex d IIC T4• ATEX II 1/2 G Ex de IIC T4• IECEx Ex d IIC T4•CSA CI I, Div1 group B, C, D•CSA CI I, Div2 group A, B, C, D•CSA CI I, zone1/zone2 IIC T4Option:Temp.classT6

• ATEX II 1/2 G Ex d [ia] IIC T4• ATEX II 1/2 G Ex de [ia] IIC T4• IECEx Ex d [ia] IIC T4•CSA CI I, Div1 group B, C, D•CSA CI I, Div2 group A, B, C, D•CSA CI I, zone1/zone2 IIC T4Option:Temp.classT6

SR unit, zone 2 ATEXII3GExnAIIT4

MCUP, zone 1MCUP, zone 2

ATEX II 2 G Ex de IIC T6 ATEXII3GExnAIIT4;CSACII,Div2;CII,zone2

Protection class SR unit Zone1:IP65/67;zone2:IP65

CSA:IP65,enclosuretype4 CSA:IP65/67,encl.type6 CSA:IP65,enclosuretype4

Control unit MCUP Zone1:IP66;Zone2,Div2:IP66,enclosuretype4;Non-ex:IP66,IP20(19"version)

Inputs, outputs, controls via MCUP control unit (process version)

Analog output 1outputactive:0/2/4…22mA,max.load500Ω 6),accordingtoNAMURNE43

Analog inputs 2inputs:0...20mA 6)

Digital outputs Pulse/frequencyoutput(opt.module);5outputs Statussignals:operation/malfunction,maintenance,checkcycle,limitvalue,maint.request 6)

Digital inputs 2inputsforconnectionoffloatingcontacts 6)

Interfaces •USB•RS-232/-485(RS-485atex-protectedMCUP)

•RS-485viaoptionalinterfacemodule•Ethernet via optional interface module

Bus protocol (option) •MODBUS viaRS-485•PROFIBUS DP viaRS-485•TCP/IP via Ethernet

•HARTBUS•Foundation Fieldbus

1) Depending on process conditions 2) For fully developed flow profile3) Ofreading,atrange0.3uptomax.valueofmeas.range

Ofreading,atrange>1m/suptolastvalueofcal.range(flowcal.devices)

4) Flow calibrated5) Hydrocarbons6) Option: additional inputs/outputs when using I/O modules

fLoWSIc100 flare Gasmassflowmeasuringdevice