2
Personal Protective Equipment: What must be worn when you work in the laboratory.
1. PPE
Eye Protection
Lab Coat
Long Pants
Closed Toed Shoes – no exposed skin around feet
Lab gloves – when required
3
Eye Protection• Contact lenses are OK as long as glasses/goggles are worn• Prescription glasses – you must wear goggles over them• Safety goggles are provided in organic labs in UV irradiating
cabinets• Eye wash stations are present in all labs
4
• Clothing must cover all exposed skin including legs/ankles
• Stockings or leggings do not provide good coverage
• Sandals, flip-flops, Crocs, open-toe and open-top (i.e. ballet flat) shoes and canvas shoes (i.e. Toms) are not appropriate. These are not going to protect your feet if you drop a piece of glass with a liquid chemical reagent in it.
Clothing and Foot Protection
5
Use of Gloves
Remove gloves before handling objects such as doorknobs, telephones, pens, computer keyboards, pH meter or other electronic buttons, or phones while in lab. It might be convenient to have one gloved hand and one ungloved hand to do procedures where these kinds of things are used.• Throw away gloves anytime you take them off.• You should expect to use several pairs of gloves
in any given lab period.• Glove video
6
Eyewash / Safety ShowerThe eyewash is on the left. Pull the handle and a fountain of water will appear that you can use to bathe your eyes.
The safety shower is on the right. Pull the handle and water will start spraying from the shower head on the ceiling. There’s no drain in the floor – we only do this in emergencies, because a flood of water will have to be cleaned up.
9
Using the Fume Hoods properly
If this is not saying NORMAL, then the hood is not protecting you. Keeping the sashand sliding panels in proper position keeps thisNORMAL, otherwise the alarm goes off. If the alarm goes off, you need to reposition things to the correct positions, then press the “mute” button to reset the controller.
The sash should never be raised abovethe green “operation” level when youare working in the hood.
This window/bar is called the sash.
10
×✓
✓✓
Closed, not in use In use, side-to-side panel used as shield
In use, sash (window) raised to less than 18 inches
Don’t open side shields to make one big window.
11
• When using a laboratory hood, Check that the airflow is in the normal range on the digital display
• Turn on the hood light• Set the equipment and chemicals back at least 6 inches.• Never lean in and/or put your head in the hood when
you are working. This is worse than doing the experiment with no hood at all.
• It’s a good idea to put liquid reagent containers in trays to catch all spills and drips
15
Types of Fire Extinguishers
Most of our fire extinguishers are ABC.It contains a dry powder to put out the kinds of fires we might encounter in the chemistry labs where we have class.
This is a special fire extinguisher for combustible metal fires. It is a type D fire extinguisher. You won’t need to use this unless you work in a research lab with combustible metals.
16
Student Reaction in a Fire
Although we want you to be informed on the operation of a fire extinguisher, we do not expect you to use it. If a fire is ignited in your area, the proper STUDENT response is to:
1) Notify everyone in the room2) If possible shutdown any reaction in progress by removing
heat/energy source3) Proceed to the nearest exit and pull the nearest fire alarm4) Evacuate the building5) Assemble in front of the library or in the YWCA parking lot
for a positive headcount
17
Keep your lab area clean.
××××Throw away used
paper towels and used gloves, immediately.
Don’t block the floor in front of the eyewash/shower station.
Don’t leave things in the floor because someone will trip over it.
Don’t leave cords dangling because someone will trip over them.
18
843-953-5611Please take a moment now to program this number into your cell phone.
Once again, the number to call in an emergency is:
Cryogens
• Cryogens: liquefied gases that are kept in their liquid state at very low temperatures.
• Used to access low temperatures• Boiling points below -150°C (- 238°F)• High expansion ratios (average 700:1)• When they are heated (room temperature)
they vaporize very rapidly – If volume cannot be expanded, the pressure will
increase and possibly blow something up
Handling Cryogens
• Know the properties of the cryogens before handling them
• Examine equipment before use• Many materials shrink, become brittle, or
crack at such low temperatures, so take care when selecting materials to be used with cryogens.
• Spilled cryogens can expand to gas rapidly and displace air in enclosed areas
Handling Cryogens• If using cryogens to cool an object,
insert the object slowly using tongs– this minimizes boiling and splashing
• Jewelry can freeze to exposed skin• Exposure can cause severe frostbite• Always wear proper PPE that coversLegs, feet, and arms, safety glasses orFace shield and thermal gloves
CryogenBoiling point (1 atm) °C (°F)
Critical pressurepsiga
Liquid density, g/L
Gas density (27°C), g/L
Liquid-to-gas expansion ratio
Type of gas
Ar -186(-303) 710 1402 1.63 860 Inert
He -269(-452) 34 125 0.16 780 Inert
H2 -253(-423) 188 71 0.082 865 Flammable
N2 -196(-321) 492 808 2.25 710 Inert
O2 -183(-297) 736 1410 1.4 875 Oxygenb
CH4 -161 (-256) 673 425 0.72 650 Flammable
Physical Properties of Common Cryogenic Liquids
Using Dewars• A Dewar is the typical container used to store and handle
cryogenic liquids • A multi-walled design with a vacuum jacket for insulation and
pressure relief valves to protect against over-pressurization • Containers filled with cryogens should never be capped tightly
Liquid Nitrogen Safety• LN2 rapidly evaporates and can displace air
in enclosed spaces causing suffocation• LN2 can cause death of human tissue from
extreme cold• Minor contact can cause “burns”• Evacuated glass dewars can sometimes burst
unexpectedly• LN2 can condense liquid oxygen, a highly
reactive and flammable liquid
Liquid Nitrogen DON’T’s
• DON’T use in confined space• DON’T freeze items in centrifuge tubes with snap caps• DON’T transport LN2 in a closed automobile • DON’T transport LN2 in a passenger elevator• DON’T allow a storage dewar to tip over• DON’T leave cold fingers on a vacuum line in LN2
overnight• DON’T use without PPE!
NO!
Liquid Nitrogen Do’s• DO use or dispense LN2 only in well ventilated areas• DO ensure glass dewars are taped or wrapped• DO use approved containers only such as a dewar or
threaded cryovials for storage• DO make sure any vessel with LN2 is VENTED• DO secure storage dewars against spilling• DO use appropriate PPE which includes:• Face shield (or minimally goggles)• Long thermal gloves• Apron or lab coat• Closed toed Shoes• Long pants
YES!
NO!
YES!
Special Note on LN2 transport for Chemistry Magic Shows
• Use only a sturdy LN2 dewar• Keep windows of car open• Do not put LN2 next to any passenger in the car• Secure the LN2 such that it cannot tip over (use seatbelt, other
heavy, bulky objects to block it in)• Be prepared to leave the vehicle if a spill occurs• Do NOT allow K-12 students to touch LN2 • Do NOT allow K-12 students to approach your glass dewar without
goggles
Nanomaterials (CdSe QDs)• Particles that are 100 nanometers or less in size and behave as a whole
unit in terms of its transport and properties. • The reactivity of many conventional materials change when in
nanoparticle form• The toxicology of many nanomaterials have not been determined• Full PPE should always be worn when working with nanoparticles and
lab coats and other contaminated clothing may need to be professionally laundered
• Absorption and inhalation are common exposure routes• Nanomaterials can accumulate in areas of the body remote from the
area of exposure
• Nanomaterials
29
Gas Cylinders
• http://www.youtube.com/watch?v=mReuQCuJNQQ• A gas cylinder will become a missile if the valve is broken
or cracked.• For this reason, gas cylinders must always be securely
chained to a wall or a permanent bench in the lab. The chain should not be loose.
• If a cylinder is not in use or is going to be moved, it must be capped to protect you and everyone else in the building.
• Do not attempt to move a gas cylinder until you have been trained on this important procedure.
Gas Regulators
• Flammable gases and inert gases have different types of regulators---do not mix!
• One gauge measures the internal tank pressure and the other gauge can be adjusted to regulate the output pressure
• Know the pressure limits of the equipment that you are attaching to the regulator on the output side
• Never open a tank without a regulator• Only make small incremental adjustments
to output pressure
Valve to adjust output pressure
Gas Tank Labels• It is important to
know when a tank is empty or pressurized
• Standard labels are attached to tanks on delivery and should be modified by user as the tank is being used and then emptied
Manipulating Gas Cylinders
• Gas Cylinder Use