PHASE SPLITTER INSTALLATION GUIDE
Transcript of PHASE SPLITTER INSTALLATION GUIDE
1 Scope of delivery
Check the delivery for completeness and externally visible damage. Contact your specialist dealer in case of an incomplete delivery or damage.
3x Wire bridges 10 mm2, 60 cm 2x Potential collector terminal
1x Installation guide
Version: 05/2017 | Rev. 000 | AZ-TM-PME-1125 | Subject to change | © 2017 SOLARWATT GmbH | PAGE 3
2 Validity
This document is intended for qualified persons. The activities described here must only be carri-ed out by persons with the following minimum qualifications:• Training in the installation and commissioning of electrical devices• Training with respect to electrical hazards and locally applicable safety requirements• Knowledge of the applicable standards and directives• Familiarity and compliance with this document and all safety instructions.
3 Intended use
The Phase Splitter is an add-on installation kit to be used for installations in which the single-phase house connection cables have a diameter greater than 16mm² and/or an inco-
ming current larger than 63A. The installation of the Phase Splitter is only to be used in com-bination with installation instructions for the SOLARWATT AC Sensor 63.
4 Safety instructions
• To ensure that the cross-section of an in-coming cable is not undershot, all 3 cables supplied must be connected.
• The phase splitter must not be used with incoming cables with a cross-section lar-ger than 30 mm².
• If the cables supplied are too short for your arrangement of the clamps and ACS63, ca-bles must be custom made which fulfill the following criteria:
- Same length, same cross-section, same material
- Wire end ferrules, if necessary accor-ding to local installation instructions
• The installer is responsible for correct in-stallation
• Only the connections described in the in-structions may be made. Do not connect other cables to the free terminals..
5 Technical data for the potential collector
You can find further technical data on the potential collection terminals from PhoenixContact at www.phoenixcontact.com under the material number 3213142.
Number of poles 1
Number of connections 5
Potentials 1
Nominal cross section 70 mm²
Rated current IN189 A(due to the maximum measuring current of AC Sensor 63)
PAGE 4 | Version: 05/2017 | Rev. 000 | AZ-TM-PME-1125 | Subject to change | © 2017 SOLARWATT GmbH
6 Phase splitter set description
The Phase Splitter splits the phase (phase con-ductors) in the house line from a diameter greater than 16mm² to 3 x 10mm² in order to also equip single-phase households with an AC sensor 63, as
well as households which have connection cable with a diameter greater than 16mm² and/or an in-coming current larger than 63A.
6.1 AC-Sensor 63 (ACS 63)
MyReserve CAN communication (B)
Energy Manager CAN communication (C)
Feeds for external conductors(current measurement) (D)
Connection area for external conductor and neutral conductor (voltage measurement) (A)
6 RU (10.8 cm)
6.2 Potential collector terminal
Main phase connection >16 mm2 and <30 mm2
Wire bridges connection 10 mm2
Version: 05/2017 | Rev. 000 | AZ-TM-PME-1125 | Subject to change | © 2017 SOLARWATT GmbH | PAGE 5
7 Connection and installation
IMPORTANTObserve the 5 safety rules!
The AC Sensor 63 must be installed between the utility meter and the fuse box.
PAGE 6 | Version: 05/2017 | Rev. 000 | AZ-TM-PME-1125 | Subject to change | © 2017 SOLARWATT GmbH
Place the potential collectors and the AC sensor 63 on a free DIN mounting rail in the main fuse box or in a separate housing. Wire the components according to the following connection dia-gram. Make sure that you clamp the terminals L1, L2 and L3 (A).
Version: 05/2017 | Rev. 000 | AZ-TM-PME-1125 | Subject to change | © 2017 SOLARWATT GmbH | PAGE 7
Electronic devices must be disposed of in accordance with the locally applicable waste disposal regulations for electronic scrap.
CONTACT
Are you interested in our products and services?
We'll be glad to advise you. Just give us a call.
If you are experiencing technical problems with the product, please use the service hotline.
We will need the following information to assist you further:
Type and serial number of the ACS (can be read on the type plate)
Type and serial number of the device receiving the measurements from the ACS on the CAN bus
Provide as much detail as possible when describing the error