PFP Instrument Status All PFP Instruments Except SWEA have been delivered, integrated, and tested; supporting environmental tests Issues: EUV alignment shims not flat re-shimmed, CLOSED SEP temperature sensor noise Temp sensors relocated; now quiet, CLOSED SEP Heater noise (from TAME) Plan to shield heaters; works on EM, installed on FM this week? MAG temperature monitor offset Monitor temperature calibration updated. Missing Time Update Counter Spacecraft flight software fix planned SASM/LPW timing offset Phase difference identified (on PFP side) Identified an operational fix, which works on EM but has not yet been tested on FM

Transcript of PFP Instrument Status All PFP Instruments Except SWEA have been delivered, integrated, and tested;...

Page 1: PFP Instrument Status All PFP Instruments Except SWEA have been delivered, integrated, and tested; supporting environmental tests Issues: –EUV alignment.

PFP Instrument Status

• All PFP Instruments Except SWEA have been delivered, integrated, and tested; supporting environmental tests

• Issues:– EUV alignment shims not flat

• re-shimmed, CLOSED– SEP temperature sensor noise

• Temp sensors relocated; now quiet, CLOSED– SEP Heater noise (from TAME)

• Plan to shield heaters; works on EM, installed on FM this week?– MAG temperature monitor offset

• Monitor temperature calibration updated.– Missing Time Update Counter

• Spacecraft flight software fix planned– SASM/LPW timing offset

• Phase difference identified (on PFP side)• Identified an operational fix, which works on EM but has not yet

been tested on FM

Page 2: PFP Instrument Status All PFP Instruments Except SWEA have been delivered, integrated, and tested; supporting environmental tests Issues: –EUV alignment.

SWEA Status

• High Voltage Discharges and instability in Thermal Vac• Reworked instrument to stabilize over temperature and

reduce the risk of discharges and reduce the risk of damage should a discharge occur

• Instrument reassembled and in test:– Test in calibration chamber with high voltage, no issues– Vibrated, no issues– Tested again in calibration chamber, no issues– In thermal vacuum, no problem with first few cycles

• High voltage powered on Cycle 5 (2/19) with no problems– Post-environmental; calibration next week

• Pre-Ship Review Friday 3/1; Delivery to LM Monday 3/4, ready for integration after bench test, as soon as the afternoon of 3/5.

Page 3: PFP Instrument Status All PFP Instruments Except SWEA have been delivered, integrated, and tested; supporting environmental tests Issues: –EUV alignment.

SWEA In Calibration Chamber