Peter A. Cripton, Ph.D., P.Eng. · 2015-07-13 · Peter A. Cripton, Ph.D. Page 2 10/13 • Winner...

22
01/13 820 W. Broadway, Suite 202, Vancouver, British Columbia, Canada, V5Z 1J8 P: 604-872-1788 F: 604-608-4814 www.synapacg.com Peter A. Cripton, Ph.D., P.Eng. Principal Engineer Dr. Peter A. Cripton is the Chief Executive Officer of Synaptic Analysis Consulting Group and a Principal Engineer. Dr. Cripton addresses issues involving traumatic human injury and medical device design and failure. He has expertise in the areas of human tolerance to injury, especially spine and spinal cord injury and hip injury, and the analysis of dynamic events such as rollovers. His work includes analysis of injuries occurring in sports, transportation and occupational accidents and those involving consumer products. In the medical device area, he has expertise in the efficacy and failure of surgically implantable orthopaedic devices with an emphasis on those used in spine surgery. His technical skills also include materials testing systems, tribological testing machines, strain measurement techniques, custom-load cell development, three dimensional motion measurement and analysis, impact apparatus development and associated high-speed data collection. Dr. Cripton is an Associate Professor of Mechanical Engineering and an Associate Faculty member in the Department of Orthopaedics at the University of British Columbia (UBC) in Vancouver, Canada. Within the Department of Mechanical Engineering he is the Patrick Campbell Chair in Mechanical Design. At UBC he co-directs the Orthopaedic and Injury Biomechanics Group and he is a Principal Investigator in the ICORD spinal cord injury research centre, in the UBC Brain Research Centre and in the Centre for Hip Health and Mobility. Dr. Cripton has previously held positions as a Managing Engineer at Exponent Failure Analysis Associates in Philadelphia, as a postdoctoral associate at the Biomechanics Research Laboratory in the Department of Orthopaedics and Rehabilitation at Yale University and as a research fellow at the Maurice E. Müller Institute for Biomechanics at the University of Bern in Switzerland. Education and Awards Ph.D., Mechanical Engineering, Queen’s University, Canada, 1999 M.S., Mechanical Engineering, Queen’s University, Canada, 1993 B.S., Mechanical Engineering, Technical University of Nova Scotia, 1990 B.S., Mathematics, Dalhousie University, Canada, 1987 NDI Young Investigator award for: Newell R (presenter), Siegmund G, Blouin JS, Street J, Cripton PA, Preparing for headfirst impact affects the muscle activity and posture of the neck, Conference for the Canadian Society of Biomechanics, June 6-9, 2012, Burnaby, Canada. University of British Columbia, Killam Teaching Prize 2011-2012 Best Presentation Award (Margaret Hines Award) at the 2010 Ohio Injury Biomechanics Symposium (PhD student Claire Jones Presenting) University of British Columbia, Killam Faculty Research Fellowship 2009-2010

Transcript of Peter A. Cripton, Ph.D., P.Eng. · 2015-07-13 · Peter A. Cripton, Ph.D. Page 2 10/13 • Winner...

01/13

820 W. Broadway, Suite 202, Vancouver, British Columbia, Canada, V5Z 1J8 P: 604-872-1788 F: 604-608-4814 www.synapacg.com

Peter A. Cripton, Ph.D., P.Eng. Principal Engineer Dr. Peter A. Cripton is the Chief Executive Officer of Synaptic Analysis Consulting Group and a Principal Engineer. Dr. Cripton addresses issues involving traumatic human injury and medical device design and failure. He has expertise in the areas of human tolerance to injury, especially spine and spinal cord injury and hip injury, and the analysis of dynamic events such as rollovers. His work includes analysis of injuries occurring in sports, transportation and occupational accidents and those involving consumer products. In the medical device area, he has expertise in the efficacy and failure of surgically implantable orthopaedic devices with an emphasis on those used in spine surgery. His technical skills also include materials testing systems, tribological testing machines, strain measurement techniques, custom-load cell development, three dimensional motion measurement and analysis, impact apparatus development and associated high-speed data collection. Dr. Cripton is an Associate Professor of Mechanical Engineering and an Associate Faculty member in the Department of Orthopaedics at the University of British Columbia (UBC) in Vancouver, Canada. Within the Department of Mechanical Engineering he is the Patrick Campbell Chair in Mechanical Design. At UBC he co-directs the Orthopaedic and Injury Biomechanics Group and he is a Principal Investigator in the ICORD spinal cord injury research centre, in the UBC Brain Research Centre and in the Centre for Hip Health and Mobility. Dr. Cripton has previously held positions as a Managing Engineer at Exponent Failure Analysis Associates in Philadelphia, as a postdoctoral associate at the Biomechanics Research Laboratory in the Department of Orthopaedics and Rehabilitation at Yale University and as a research fellow at the Maurice E. Müller Institute for Biomechanics at the University of Bern in Switzerland.

Education and Awards

Ph.D., Mechanical Engineering, Queen’s University, Canada, 1999 M.S., Mechanical Engineering, Queen’s University, Canada, 1993 B.S., Mechanical Engineering, Technical University of Nova Scotia, 1990 B.S., Mathematics, Dalhousie University, Canada, 1987 • NDI Young Investigator award for: Newell R (presenter), Siegmund G, Blouin JS, Street J,

Cripton PA, Preparing for headfirst impact affects the muscle activity and posture of the neck, Conference for the Canadian Society of Biomechanics, June 6-9, 2012, Burnaby, Canada.

• University of British Columbia, Killam Teaching Prize 2011-2012 • Best Presentation Award (Margaret Hines Award) at the 2010 Ohio Injury Biomechanics

Symposium (PhD student Claire Jones Presenting) • University of British Columbia, Killam Faculty Research Fellowship 2009-2010

Peter A. Cripton, Ph.D. Page 2 10/13

• Winner (with Tim Nelson) of a 2008 Popular Science “Best of What's New” award in the Personal Health category for co-inventing the Pro-Neck-Tor helmet. 100 new products and technologies that span 11 categories are given this award annually.

• Best Presentation Award (Margaret Hines Award) at the 2008 Ohio Injury Biomechanics Symposium (PhD student Tim Nelson Presenting)

• Cervical Spine Research Society, 2001 Research Grant Award • Natural Sciences and Engineering Research Council of Canada, Postdoctoral Research

Fellowship, 1999

• Reviewer: Journal of Biomechanics, European Spine Journal, Biomed Central, Annals of Biomedical Engineering, Spine, Medical Engineering and Physics, Clinical Biomechanics, Canadian Space Agency, Natural Sciences and Engineering Research Council (Canada), Canadian Institutes of Health Research, National Science Foundation (US), Ohio State University

Memberships

• International Society of Biomechanics (member); • American Society for Testing Materials (member); • American Society for Testing Materials Committee F08 (Sports Equipment, Playing

Surfaces and Facilities) (member) • Orthopaedic Research Society (member) • Society of Automotive Engineers (member) • Canadian Association of Technical Accident Investigators and Reconstructionists (Member)

Peer Reviewed Publications

Dressler D, Dennison CR, Cripton PA. Development of an advanced football helmet to provide increased protection against concussion. Journal of ASTM (STP), 2014 (in press)

Shetye SS, Troyer KL, Streijger F, Lee JHT, Kwon BK, Cripton PA, Puttlitz CM. Nonlinear viscoelastic characterization of the porcine spinal cord. Acta Biomaterialia. 2014;10(2):792–797.

Van Toen C, Melnyk AD, Street J, Oxland TR, Cripton PA. The effect of lateral eccentricity on failure loads, kinematics, and canal occlusions of the cervical spine in axial loading. Journal of Biomechanics. 2013. (epub ahead of print). doi 10.1016/j.jbiomech.2013.12.001

Cripton PA. Perspective: Protecting the neck. Nature. 2013;503(7475):S13.

Gilchrist S, Guy P, Cripton PA. Development of an inertia-driven model of sideways fall for detailed study of femur fracture mechanics. Journal of Biomechanical Engineering. 2013;135(12):121001-121001.

Jones CF, Lee JHT, Burstyn U, Okon EB, Kwon BK, Cripton PA. Cerebrospinal fluid pressures resulting from experimental spinal cord injuries in a pig model Journal of Biomechanical Engineering. 2013;135(10):101005-101005.

Peter A. Cripton, Ph.D. Page 3 10/13

Saari A, Dennison CR, Zhu Q, Nelson TS, Morley P, Itshayek E, Oxland TR, Cripton PA. Compressive follower load influences cervical spine kinematics and kinetics during simulated head-first impact in an ex vivo model. Journal of Biomechanical Engineering. 2013;135(11):111003.

Namjoshi DR, Good C, Cheng WH, Panenka W, Richards DR, Cripton PA, Wellington CL, Towards clinical management of traumatic brain injury: a review of models and mechanisms from a biomechanical perspective. Disease Models and Mechanisms. 2013;6(6):1325-1338.

Newell RS, Blouin JS, Street J, Cripton PA, Siegmund GP. Neck posture and muscle activity are different when upside down: A human volunteer study. Journal of Biomechanics. 2013;46(16):2837-2843.

Teschke K, Harris MA, Reynolds CCO, Shen H, Cripton PA, Winters M. Exposure-based Traffic Crash Injury Rates by Mode of Travel in British Columbia. Canadian Journal of Public Health. 2013;104(1):e75–e79.

Melnyk AD, Kingwell SP, Zhu Q, Chak JD, Cripton PA, Fisher CG, Dvorak MF, Oxland TR. An in vitro Model of Degenerative Lumbar Spondylolisthesis. Spine 2013;(epub ahead of print April 3, 2013)

Harris MA, Reynolds CCO, Winters M, Cripton PA, Shen H, Chipman ML, Cusimano MD, Babul S, Brubacher JR, Friedman SM, Hunte G, Monro M, Vernich L, Teschke K. Comparing the effects of infrastructure on bicycling injury at intersections and non-intersections using a case-crossover design. Injury Prevention 2013; (epub ahead of print February 14, 2013)

Nishiyama KK, Gilchrist S, Guy P, Cripton PA, and Boyd SK, Proximal femur bone strength estimated by a computationally fast finite element analysis in a sideways fall configuration. Journal of Biomechanics 2013;46(7);1231-6.

Lee JHT, Jones CF, Okona EB, Anderson L, Tigchelaara S, Koonera P, Godbey T, Chu B, Gray G, Hildebrandt R, Cripton PA, Tetzlaff W, Kwon BK, A Novel Porcine Model of Traumatic Thoracic Spinal Cord Injury. Journal of Neurotrauma, 2013: 30(3): 142-59.

Dressler D, Richards D, Bates E, Van Toen C, Cripton PA, Head and Neck Injury Potential with and without Helmets during Head-First Impacts on Snow. Skiing Trauma and Safety, ASTM International STP 1553. (doi:10.1520/ STP104525) Teschke K., Harris MA, Reynolds CCO, Winters M, Babul S., Chipman M., Cusimano M., Brubacker J., Friedman S.M., Hunte G., Munro M., Shen H., Vernich L., Cripton P.A., Route Infrastructure and the risk of injuries to bicyclists: a case crossover study. AJPH 2012. (doi:10.2105/AJPH.2012.300762) Melnyk AD, Chak JD, Cripton PA, Dvorak MF & Oxland, TR Shear force measurements on low- and high-stiffness posterior fusion devices. Medical Engineering & Physics 2012.doi:10.1016

Harris MA, Cripton PA, Teschke K. Retrospective assessment of occupational exposure to whole-body vibration for a case-control study. J Occup Environ Hyg. 2012;9(6):371–80.

Peter A. Cripton, Ph.D. Page 4 10/13

Jones CF, Kwon BK, Cripton PA. Mechanical indicators of injury severity are decreased with increased thecal sac dimension in a bench-top model of contusion type spinal cord injury. J Biomech. 2012;45(6):1003–10.

Van Toen C, Sran MM, Robinovitch SN, Cripton PA. Transmission of force in the lumbosacral spine during backward falls. Spine. 2012;37(9):E519–527.

Wilson DC, Connolly RJ, Zhu Q, Emery JL, Kingwell SP, Kitchel S, et al. An ex vivo biomechanical comparison of a novel vertebral compression fracture treatment system to kyphoplasty. Clin Biomech (Bristol, Avon). 2012;27(4):346–53.

Dennison CR, Macri EM, Cripton PA. Mechanisms of cervical spine injury in rugby union: is it premature to abandon hyperflexion as the main mechanism underpinning injury? Br J Sports Med. 2012;46(8):545–9.

Jones CF, Lee JHT, Kwon BK, Cripton PA. Development of a large-animal model to measure dynamic cerebrospinal fluid pressure during spinal cord injury: Laboratory investigation. J Neurosurg Spine. 2012;16(6):624–35.

Zhu Q, Itshayek E, Jones CF, Schwab T, Larson CR, Lenke LG, et al. Kinematic evaluation of one- and two-level Maverick lumbar total disc replacement caudal to a long thoracolumbar spinal fusion. Eur Spine J. 2012;21 Suppl 5:S599–611.

Van Toen C, Street J, Oxland TR, Cripton PA. Acoustic emission signals can discriminate between compressive bone fractures and tensile ligament injuries in the spine during dynamic loading. J Biomech. 2012;45(9):1643–9.

Jones CF, Cripton PA, Kwon BK. Gross morphological changes of the spinal cord immediately after surgical decompression in a large animal model of traumatic spinal cord injury. Spine. 2012;37(15):E890–899.

Sjovold SG, Zhu Q, Bowden A, Larson CR, de Bakker PM, Villarraga ML, et al. Biomechanical evaluation of the Total Facet Arthroplasty System(®) (TFAS (®)): loading as compared to a rigid posterior instrumentation system. Eur Spine J. 2012;21(8):1660–73.

Jones CF, Newell RS, Lee JHT, Cripton PA, Kwon BK. The Pressure Distribution of Cerebrospinal Fluid Responds to Residual Compression and Decompression in an Animal Model of Acute Spinal Cord Injury. Spine [Internet]. 2012[cited 2012 Oct 1]; Available from: http://www.ncbi.nlm.nih.gov/pubmed/22869059

Melnyk AD, Wen TL, Kingwell S, Chak JD, Singh V, Cripton PA, et al. Load transfer characteristics between posterior spinal implants and the lumbar spine under anterior shear loading: an in vitro investigation. Spine. 2012;37(18):E1126–1133.

Teschke K, Brubacher JR, Friedman SM, Cripton PA, Harris MA, Reynolds CC, et al. Personal and trip characteristics associated with safety equipment use by injured adult bicyclists: a cross-sectional study. BMC Public Health. 2012;12(1):765.

Van Toen, C., Sran, M. M., Robinovitch, S. N. & Cripton, P. A. Transmission of Force in the Lumbosacral Spine During Backward Falls. Spine (2011).doi:10.1097

Wilson DC, Connolly RJ, Zhu Q, Emery JL, Kingwell SP, Kitchel S, Cripton PA, Wilson DR An ex vivo biomechanical comparison of a novel vertebral compression fracture treatment

Peter A. Cripton, Ph.D. Page 5 10/13

system to kyphoplasty. Clinical Biomechanics (Bristol, Avon). (2011) doi:10.1016/j.clinbiomech.2011.11.001

Saari A, Itshayek E, Cripton PA. Cervical Spinal Cord Deformation during simulated head first impact injuries. (2011) Journal of Biomechanics;44(14):2565-71

Harris MA, Reynolds CC, Winters M, Chipman M, Cripton PA, Cusimano MD, Teschke K. (2011) The Bicyclists' Injuries and the Cycling Environment study: a protocol to tackle methodological issues facing studies of bicycling safety. Injury Prevention;17:e6

Nelson TS, Cripton PA. A new Biofidelic Sagittal Plane Surrogate Neck for Head-First Impacts. (2010) Traffic Injury Prevention;11:309-319.

Greaves LL, Van Toen (Née Greaves) C, Melnyk A, Koenig L, Zhu Q, Tredwell S, Mulpuri K, Cripton PA. (2009) Pediatric and adult three-dimensional cervical spine kinematics: effect of age and sex through overall motion. Spine;34:1650-7.

Cameron ID, Robinovitch S, Birge S, Kannus P, Khan K, Lauritzen J, Howland J, Evans S, Minns J, Laing A, Cripton P, Derler S, Plant D, Kiel DP. (2009) Hip protectors: recommendations for conducting clinical trials-an international consensus statement (part II). Osteoporosis International. DOI 10.1007/s00198-009-1055-2.

Robinovitch SN, Evans SL, Minns J, Laing AC, Kannus P, Cripton PA, Derler S, Birge SJ, Plant D, Cameron ID, Kiel DP, Howland J, Khan K, Lauritzen JB. (2009) Hip protectors: recommendations for biomechanical testing-an international consensus statement (part I). Osteoporosis International. DOI 10.1007/s00198-009-1045-4.

Reynolds CC, Harris MA, Teschke K, Cripton PA, Winters M. The impact of transportation infrastructure on bicycling injuries and crashes: a review of the literature. Environmental Health 2009;8:47.

deBakker PM, Manske SL, Ebacher V, Oxland T, Cripton PA, Guy P. (2009) During sideways falls proximal femur fractures initiate in the superolateral cortex: evidence from high-speed video of simulated fractures. Journal of Biomechanics;42(12):1917-25.

Kroeker SG, Bilston LE, Morley P, Cripton PA. (2009) An improved physical model of the in vivo human spinal cord: Tension and Transverse Compression. Journal of Biomechanics;42(7):878-83.

Ramchandani SR, Panjabi MM, Cripton PA, VanderWeele TJ. (2008) Biomechanical evaluation of intervertebral discs following a burst fracture. Journal of Musculoskeletal Research;11(3):1-10.

Vorrink S, van der Woude L, Messenberg A, Cripton PA, Hughes B, Sawatzky B. A. (2008) comparison of wheelchair wheels in terms of vibration and spasticity in people with a spinal cord injury. Journal of Rehabilitation Research and Development; 45(9):1269-79.

Blair J, Perdios A, Babul S, Young K, Beckles J, Pike I, Cripton PA, Sasges D, Mulpuri K, Desapriya E. (2008) The appropriate and inappropriate use of child restraint seats in Manitoba. International journal of injury control and safety promotion; 15:151-6.

Beadon K, Johnston J, Siggers K, Itshayek E, Cripton PA. (2008) Biomechanical simulation of spondylolysis and spondylolisthesis: an in vitro porcine model. Spine; 33:2387-93.

Peter A. Cripton, Ph.D. Page 6 10/13

Dennison CR, Wild PM, Wilson DR, Cripton PA. (2008) A minimally invasive in-fibre Bragg grating sensor for intervertebral disc pressure measurements. Measurement Science & Technology; 19:085201 (12 pp).

Dennison CR, Wild PM, Dvorak MF, Wilson DR, Cripton PA. (2008) Validation of a novel minimally invasive intervertebral disc pressure sensor utilizing in-fibre Bragg gratings in a porcine model: an ex vivo study. Spine;33:E589-94.

Jones CF, Kroeker (Née Reed) SG, Cripton PA, Hall RM. (2008) The effect of cerebrospinal fluid on the biomechanics of spinal cord: an ex vivo bovine model using bovine and physical surrogate spinal cord. Spine;33:E580-8.

Louman-Gardiner K, Mulpuri K, Perdios A, Tredwell S, Cripton PA. (2008) Pediatric lumbar Chance fractures in British Columbia: chart review and analysis of the use of shoulder restraints in MVAs. Accident Analysis and Prevention;40:1424-9.

Zhu, Q., Park, Y., Sjovold, S.G., Niosi, C.A., Wilson, D.C., Cripton, P.A., Oxland, T.R. (2008) Can extra-articular strains be used to measure facet contact forces in the lumbar spine? An in vitro biomechanical study. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 22(2):171-184

Dennison, CR, Wild PM, Byrnes PW, Saari A, Itshayek E, Wilson DC, Zhu QA, Dvorak MF, Cripton PA, Wilson DR (2008), Ex vivo measurement of lumbar intervertebral disc pressure using fiber-Bragg gratings. Journal of Biomechanics. 41(1):221-5

Zhu Q., Lane C., Ching R.P., Gordon J.D., Fisher C.G., Dvorak M.F., Cripton P.A., Oxland T.R. (2008) The degree of translational constraint influences dynamic spinal canal occlusion of the thoracic spine: an in vitro experimental study. Journal of Biomechanics. 41(1):171-9

Greaves, L.L., Zhu, Q., Cripton, P.A., Cluff, M., Greaves, C.Y., Melnyk, A., Perdios, A., Tredwell, S., Mulpuri, K. (2007) The Effect of Age and Gender on the Three-Dimensional Kinematics of the Pediatric Cervical Spine. Proceedings, SAE Digital Human Modeling Conference, SAE No. 2007-01-2495.

Tan J.S., Bailey C.S., Dvorak M.F., Fisher C.G., Cripton P.A., Oxland T.R. (2007) Cement Augmentation of Vertebral Screws Enhances the Interface Strength between Interbody Device and Vertebra Body. Spine 32(3):334-41 Zhu Q., Larson C.R., Sjovold S.G., Rosler D.M., Keynan O., Wilson D.R., Cripton P.A., Oxland TR (2007) Biomechanical evaluation of the total facet arthroplasty system™: three-dimensional kinematics. Spine 32(1):55-62

Villarraga M.L., Cripton P.A., Teti S., Steffey D.S., Krisnamuthy S., Albert T., Hilibrand A., Vaccaro A. (2007) Wear and Corrosion Evaluation in Retrieved Thoraco-Lumbar Internal Fixation from 57 Patients. Spine. 31(21):2454-62

Ivancic P.C., Panjabi M.M., Ito S., Cripton P.A., Wang J.L. (2005) Biofidelic whole cervical spine model with muscle force replication for whiplash simulation. European Spine Journal 14(4): 346-55

Villarraga M.L., Bellezza A.J., Harrigan T.P., Cripton P.A., Kurtz S.M., Edidin A.A. (2005) The biomechanical effects of kyphoplasty on treated and adjacent non-treated vertebral bodies following kyphoplasty. Journal of Spinal Disorders and Techniques. 18(1):84-91

Peter A. Cripton, Ph.D. Page 7 10/13

Cripton P.A., Oxland T.R., Zhu Q.A. (2005) Use of helical axis of motion and facet joint load information in the evaluation of non-fusion spinal implants: concept and preliminary results. Roundtables in Spine Surgery; 1:22-30 (Non refereed publication)

Haberl H., Cripton P.A., Orr T.E., Beutler T., Frei H., Lanksch W.R., Nolte L.P. (2004) Kinematic response of lumbar functional spinal units to axial torsion with and without superimposed compression and flexion/extension. European Spine Journal.13:560-6

Villarraga, M.L., Cripton, P.A., Bellezza, A.J., Berlemann, U., Kurtz, S.M., Edidin, A.A. (2004) Bone and Bone Cement Stresses in the Thoraco-Lumbar Spine Following Kyphoplasty: A Finite Element Analysis. Der Orthopade (Special Issue Concerning Cementing Techniques) 33(1):48-55 (In German)

Miura T., Panjabi M.M., Cripton P.A. (2002) A Method to Simulate In vivo Cervical Spine Kinematics Using In vitro Compressive Preload. Spine. 27(1):43-48 Panjabi M.M., Miura T., Cripton P.A., Wang J.-L., Nain A.S., DuBois C. (2001) Development of a system for in vitro neck muscle force replication in whole cervical spine experiments. Spine. 26(20):2214-2219

Cripton P.A., Sati M., Orr T.E., Bourquin Y., Dumas G.A., Nolte L.-P. (2001) Animation of in vitro biomechanical tests. Journal of Biomechanics. 34(8):1091-1096

Cripton P.A., Dumas G.A., Nolte L.-P. (2001) A novel technique for measuring in vitro pressure in intervertebral discs: application to the cervical spine. Technical Note. Journal of Biomechanics. 34(4):545-9. Cripton P.A., Bruehlmann, S.B., Orr, T.E., Oxland, T.R., Nolte, L.-P. (2000) In vitro axial preload application during spine flexibility testing: towards reduced apparatus-related artefacts. Journal of Biomechanics. 33(12):1559-1568.

Cripton P.A., Jain G.M., Wittenberg R.H., and Nolte L.-P. (2000) Load sharing characteristics of instrumented lumbar spine fusions. Spine. 25(2):170-9.

Lund T., Oxland T.R., Jost B., Cripton P.A., Grassmann S., Etter C., and Nolte L.-P. (1998) Interbody cage stabilization in the lumbar spine: a biomechanical evaluation of cage design, posterior instrumentation and bone density. Journal of Bone and Joint Surgery. British Volume. 80-B:351-9.

Jost B., Cripton P.A., Lund T., Oxland T.R., Lippuner K., Jaeger P., and Nolte L.-P. (1998) Compressive strength of interbody cages in the lumbar spine: the effect of cage shape, posterior instrumentation and bone density. European Spine Journal. 7:132-41.

Berlemann U., Cripton P.A., Rincon L., Nolte L.-P., and Schlapfer F. (1996) Pull-out strength of pedicle hooks with fixation screws: influence of screw length and angulation. European Spine Journal. 5:71-3.

Oxland T.R., Lund T., Jost B., Cripton P.A., Lippuner K., Jaeger P., and Nolte L.-P. (1996) The relative importance of vertebral bone density and disc degeneration in spinal flexibility and interbody implant performance. An in vitro study. Spine. 21:2558-69.

Berlemann U., Cripton P.A., Nolte L.-P., Lippuner K., and Schlapfer F. (1995) New means in spinal pedicle hook fixation. A biomechanical evaluation. European Spine Journal. 4:114-22.

Peter A. Cripton, Ph.D. Page 8 10/13

Cripton P.A., Berlemann U., Visarius H., Begeman P., and Prasad P. (1995) Response of the lumbar spine due to shear loading. Society of Automotive Engineers SP-1077. Paper#950662

Publications Submitted / in Revision

Conditionally Accepted

Cripton PA, Dressler DA, Stuart CA, Dennison CR, Richards DR. Bicycle helmets are highly effective at preventing head injury during head impact: Head-form accelerations and injury criteria for helmeted and unhelmeted impacts. Accident Analysis and Prevention, Conditionally accepted and in revision, May 2013

Gilchrist S, Cripton PA, Guy P. Correlation between femoral version and the mid-shaft linea aspera angle. Clinical Orthopaedics and Related Research, conditionally accepted and in revision, March 2012

Helgason B, Gilchrist S, Ariza O, Chak JD, Zheng G, Widmer RP, Ferguson SJ, Guy P, Cripton PA. Development of a balanced experimental-computational approach to understanding proximal femur fracture mechanics. Medical Engineering and Physics, conditionally accepted and in revision, September 2013

Submitted

Chapters in Books

Oxland TR, Bhatnagar T, Choo AM, Dvorak MF, Tetzlaff W, Cripton PA. Biomechanical Aspects of Spinal Cord Injury, in Studies in Mechanobiology, Tissue Engineering and Biomaterials. Bilston LE, Ed. Springer Verlag, Germany, 2012

Cripton P.A., Reed S.G., Saari A. Musculature Actuation and Biomechanics of the Spine, in Spine Technology Handbook. Kurtz SM, Ed. Elsevier Academic Press, USA, 2006 Villarraga M.L., Cripton P.A. (2004) The Clinical Performance of UHMWPE in the Spine, in The UHMWPE Handbook: Ultra-high Molecular Weight Polyethylene in Total Joint Replacement. Kurtz SM, Ed. Elsevier Academic Press, USA

Selected Presentations

Cripton, P.A., When it Comes to Biomechanics…Is an ounce of Prevention worth a pound of Cure?, Keynote address at the Ohio Injury Biomechanics Symposium, The Ohio State University, May 20, 2013 Cripton, P.A., Orthopaedic and Injury Biomechanics Research at UBC, Queen’s University Department of Surgery – Division of Orthopaedics, November 28, 2012 Cripton, P.A., Biomedical Engineering in Mechanical Engineering at UBC, Undergraduate BME Interest Group, UBC Department of Mechanical Engineering, October 12, 2012

Peter A. Cripton, Ph.D. Page 9 10/13

Cripton, P.A., Richards D., Injury Biomechanics In Litigation Consulting And In The Laboratory: How Real Impact Can Lead To High Impact, Case Studies in Forensic Biomechanics, Conference for the Canadian Society of Biomechanics, June 6-9, 2012, Burnaby, Canada. Cripton, P.A., public concussion panel: The role of biomechanics in informing equipment design and rules to prevent head injury in sports, Conference for the Canadian Society of Biomechanics, June 6-9, 2012, Burnaby, Canada.

Cripton, P.A., Siegmund G, Cervical spine posture and neck muscle activation in impending head-first impact, University of Virginia Cervical Spine Biomechanics Panel, May 11, 2012

Chak JD, Dressler D, Lee JHT, Kwon BK, Cripton PA, Porcine Model of Acute Spinal Cord Injury: Determination of Worst-Case Vibration Frequencies, Society for Neuroscience, 12-16 Nov, 2011, Washington, DC

Gilchrist S, Guy P, Cripton P. Impact Testing of a Proximal Femur in a Fall Configuration, 7th Annual Ohio Injury Biomechanics Symposium. May, 22-24, 2011, Columbus, OH, USA.

Newell R, Siegmund G, Blouin J, Street J, Cripton P. Neck posture and muscle activation: a human volunteer study comparing the effect of upright and inverted postures, 7th Annual Ohio Injury Biomechanics Symposium. May, 22-24, 2011, Columbus, OH, USA.

Gilchrist S, Guy P, Cripton PA. Digital volume correlation of a rabbit vertebra under axial loading, 19th Annual Pre-ORS Symposium on Computational Methods in Orthopaedic Biomechanics. January, 12, 2011, Long Beach, CA, USA.

Helgason B, Gilchrist S, Chak J, Ferguson P, Guy P, Cripton, PA. Comparison of full field surface strain between FEM and DIC during impact loading of the proximal femur. 19th Annual Pre-ORS Symposium on Computational Methods in Orthopaedic Biomechanics. January 12, 2011, Long Beach, CA, USA.

Harris MA, Reynolds CCO, Winters M, Chipman M, Cripton PA, Cusimano MD, Teschke K. Tackling methodological issues of studying bicycling safety: An Illustration Using the Bicyclists’ Injuries and the Cycling Environment (BICE) Study. Transportation Research Board, January 2011, Washington, D.C. USA.

Lee JHT, Okon EB, Anderson LM, Tigchelaar, S, Jones CF, Kooner P, Russell AK, Godbey T,

Chua B, Gray G, Hildebrandt R, Tetzlaff W, Cripton PA, Kwon BK, Porcine model of acute spinal cord injury – Establishing a translational intermediary for SCI therapies, Society for Neuroscience, 12-16 Nov, 2011, Washington, DC

Dressler D, Richards D, Bates E, Van Toen (Née Greaves) C, Cripton P, Neck and head injury potential during head first impacts on snow, Proceedings of the 19th International Congress on Ski Trauma and Skiing Safety, 1-7 May, 2011, Keystone, Colorado, USA

Helgason B, Gilchrist S, Chak J, Ferguson SJ, Guy P, Cripton PA, Femoral neck fracture can initiate through failure of the trabecular bone: evidence from combined multi-scale FEA and impact experiment, European Orthopaedic Research Society, 1-2 July, 2010, Davos, Switzerland

Peter A. Cripton, Ph.D. Page 10 10/13

Chak J, Gilchrist S, Helgason B, Guy P, Cripton PA, Simulating hip fracture at physiologic sideways fall velocities, European Orthopaedic Research Society, 1-2 July, 2010, Davos, Switzerland

Lucas E, Liu J, Russell C, Tetzlaff W, Cripton PA, High speed radiography used to measure dynamic spinal cord deformation in an in vivo rodent model, National Neurotrauma Symposium, 14-17 June, 2010, Las Vega, NV, USA.

Jones CF, Lee JHT, Kwon BK, Cripton PA, Cerebrospinal fluid pressure wave during spinal cord injury may contribute to primary injury in a porcine model, National Neurotrauma Symposium, 14-17 June, 2010, Las Vega, NV, USA.

Newell R, Seigmund G, Blouin JS, Cripton PA, Neck posture and muscle activiation: the design of a human volunteer study comparing the effect of upright and inverted postures, 2010 Northwest Biomechanics Symposium, 21-22 May, 2010, Seattle, WA, USA.

Lucas E, Liu J, Russell C, Tetzlaff W, Cripton PA, In vivo spinal cord deformation during quasi-static compression using x-ray and radio-opaque markers, 2010 Northwest Biomechanics Symposium, 21-22 May, 2010, Seattle, WA, USA.

Van Toen (Née Greaves) C, Street J, Oxland TR, Cripton PA, Spinal ligament and vertebral body injuries monitored by acoustic emission, 2010 Northwest Biomechanics Symposium, 21-22 May, 2010, Seattle, WA, USA.

Lucas E, Liu J, Russell C, Tetzlaff W, Cripton PA, High speed radiography used to measure dynamic spinal cord deformation in an in vivo rodent model, 6th Annual Ohio Injury Biomechanics Symposium 17-18 May, 2010, Columbus, OH, USA.

Jones CF, Lee JHT, Kwon BK, Cripton PA, Cerebrospinal fluid pressures during dynamic contusion-type spinal cord injury in a pig model, 6th Annual Ohio Injury Biomechanics Symposium 17-18 May, 2010, Columbus, OH, USA.

CF Jones, BK Kwon, PA Cripton. Cerebrospinal fluid pressures measured during spinal cord injury in a novel pig model, Proceedings of Neuroscience 2009, October 17-21, 2009, Chicago, USA

CF Jones, BK Kwon, PA Cripton. Cerebrospinal fluid pressures measured during spinal cord injury in a novel pig model, Proceedings of Neurotrauma 2009: Second Joint Symposium of the International and National Neurotrauma Societies, September 7-11, 2009, Santa Barbara, USA

Zhu QA, Jones CF, Schwab T, Larson CR, Itshayek I, Lenke LG, Cripton PA, Maverick Total Disc Replacement in the Lower Lumbar Spine Adjacent to a Long Spinal Fusion: An In Vitro Biomechanical Study of Kinematics. Proceedings of the 43rd Canadian Orthopaedic Research Society Annual Meeting; July 3-6, 2009, Whistler, Canada.

Jones CF, Itshayek E, Zhu QA, Schwab T, Larson CR, Lenke LG, Cripton PA, Vertebral Body and Facet Joint Loading with Multilevel Maverick Total Disc Replacement Adjacent to a Long Spinal Fusion. Proceedings of the 43rd Canadian Orthopaedic Research Society Annual Meeting; July 3-6, 2009, Whistler, Canada.

Boak J, Gédet P, Dvorak MF, Ferguson S, Cripton PA, Cervical Spinal Motion that Would Otherwise Be Safe, Can Cause Spinal Cord Compression in a Stenotic Spine. Proceedings of the 43rd Canadian Orthopaedic Research Society Annual Meeting; July 3-6, 2009, Whistler, Canada.

Peter A. Cripton, Ph.D. Page 11 10/13

Gilchrist S, Guy P, Cripton PA, The Effect of Anteversion on Hip Fracture Mechanics. Proceedings of the 43rd Canadian Orthopaedic Research Society Annual Meeting; July 3-6, 2009, Whistler, Canada.

Boak J, Gédet P, Dvorak MF, Ferguson S, Cripton PA, Stenosis in the cervical spinal canal causes spinal cord compression during motion that otherwise would not cause spinal cord compression. Proceedings of the 5th Annual Ohio Injury Biomechanics Symposium; May 18-19, 2009, Columbus, OH, USA.

Van Toen (Née Greaves) C, Jones CF, Nelson TS, Street J, Cripton PA, Simulation of head-first impact using cervical spine specimens, simulated neck muscles, and a Hybrid III ATD head. Proceedings of the 5th Annual Ohio Injury Biomechanics Symposium; May 18-19, 2009, Columbus, OH, USA.

Ming K, Abugharbieh R, Jones CF, Greaves CY, Yung A, Tetzlaff W, Kozlowski P, Cripton PA, Technique for quantitative analysis of cervical myelopathy using magnetic resonance imaging. Proceedings of the Cervical Spine Research Society Annual Meeting; December 4-8, 2008, Austin, USA.

Van Toen C, Sran M, Cripton PA, Robinovitch SN, Preventing fall-related vertebral fractures: effect of floor stiffness on lumbosacral spine forces. Proceedings of the BC Injury Prevention Conference; November 19-20, 2008

Cripton PA, Van Toen C, Nelson, T, Injury biomechanics research: spinal cord and hip injury prevention. Proceedings of the BC Injury Prevention Conference; November 19-20, 2008

Van Toen C, Nelson TS, Jones CF, Street J, Cripton PA, Development of an in vitro model of head-first impact with a hybrid III head, surrogate spinal cord and simulated neck muscles; Proceedings of the NHTSA 36th International Workshop on Human Subjects for Biomechanical Research; November 2, 2008, San Antonio, USA

Nelson TS, Cripton PA. Inducing head motion with a novel helmet during head-first impact can mitigate neck injury metrics: an experimental proof-of-concept investigation using mechanical surrogates. Proceedings of the International Research Council on the Biomechanics of Impacts; September 17-19, 2008; Bern, Switzerland (4 page manuscript in proceedings).

Boak J, Gédet P, Dvorak MF, Ferguson S, Cripton PA, At what point does cervical spinal canal stenosis endanger the spinal cord?; Proceedings of the third pre-IRCOBI Workshop on Biomechanical Experiments; September 16, 2008, Bern, Switzerland (4 page manuscript in proceedings).

Nelson TS, Greaves CY, Jones CF, Street J, Cripton PA, Experimental Impact to the Hybrid III Head and Cadaveric Cervical Spine with an Advanced Muscle Force Replication System; Proceedings of the third pre-IRCOBI Workshop on Biomechanical Experiments; September 16, 2008, Bern, Switzerland (4 page manuscript in proceedings).

Jones CF, Kwon BK, Cripton PA. Cerebrospinal fluid pressures associated with spinal cord injury: pilot study in a large animal model. Proceedings of the 26th Annual National Neurotrauma Symposium; July 27-30, 2008, Orlando, USA

Peter A. Cripton, Ph.D. Page 12 10/13

Ming K, Abugharbieh R, Jones CF, Greaves CY, Yung A, Tetzlaff W, Kozlowski P, Cripton PA. In vivo and non-invasive analysis of spinal cord deformations for rodent research using magnetic resonance imaging. Proceedings of the 26th Annual National Neurotrauma Symposium; July 27-30, 2008, Orlando, USA Jones CF, Itshayek E, Zhu QA, Schwab T, Larson CR, Lenke LG, Cripton PA. Evaluation of tissue loading in response to one- and two-level maverick total disc replacement adjacent to a long spinal fusion. Proceedings of the 15th International Meeting on Advanced Spine Techniques; July 8-11, 2008, Hong Kong, China. Zhu QA, Itshayek E, Jones CF, Schwab T, Larson CR, Lenke LG, Cripton PA. Kinematic evaluation of one- and two-level Maverick total disc replacement adjacent to a long spinal fusion. Proceedings of the 15th International Meeting on Advanced Spine Techniques; July 8-11, 2008, Hong Kong, China. Boak JC, Popovic D, Itshayek E, Koenig L, Dvorak MF, Cripton PA. Age-related degeneration is related to reduced cervical spine range of motion in the elderly. Proceedings of the 16th European Society of Biomechanics; July 6-9, 2008, Lucerne, Switzerland.

Boak JC, Popovic D, Itshayek E, Koenig L, Dvorak MF, Cripton PA. X-ray analysis shows degeneration is related to range of motion in the cervical spine of geriatric subjects. Proceedings of Spineweek 2008; May 26-31, 2008, Geneva, Switzerland.

Nelson TS, Cripton PA. Dynamically Modifying End Conditions in a Head-First Impact with a Novel Helmet can Mitigate Neck Injury Metrics: An Experimental Proof-of-Concept Investigation Using Mechanical Surrogates. 4th Annual Ohio Injury Biomechanics Symposium, 19-20 May, 2008, Columbus, OH, USA. (Winner of best presentation award)

Jones CF, Kwon BK, Dennison C, Itshayek E, Markez J, Singleton D, Wild P, Cripton PA. Development and pilot results from a large animal study to measure cerebrospinal fluid pressure before, during and after spinal cord injury. 4th Annual Ohio Injury Biomechanics Symposium, 19-20 May, 2008, Columbus, OH, USA.

Nelson TS, Cripton PA. Can a helmet mitigate neck injurires in head-first impacts? Proceedings of the 4th Annual Northwest Biomechanics Symposium, May 9-10, 2008, Boise, ID, USA

Chak JD, Oxland TR, Cripton PA. Creep testing using load control with spine motion simulator. Proceedings of the 4th Annual Northwest Biomechanics Symposium, May 9-10, 2008, Boise, ID, USA

Ming K, Abugharbieh R, Jones CF, Greaves CY, Yung A, Tetzlaff W, Kozloski P, Cripton PA. Finite element validation of spinal cord deformation analysis based on MR imaging data. Proceedings of the 4th Annual Northwest Biomechanics Symposium, May 9-10, 2008, Boise, ID, USA

Greaves CY, Gilchrist S, Morrison T, Cripton PA, Hunter CJ. Impact properties of bovine intervertebral discs. Proceedings of the 4th Annual Northwest Biomechanics Symposium, May 9-10, 2008, Boise, ID, USA

Peter A. Cripton, Ph.D. Page 13 10/13

Jones CF, Kwon BK, Dennison C, Wild P, Markez J, Cripton PA. A large animal model to measure cerebrospinal fluid pressures associated with spinal cord injury: development and preliminary results. Proceedings of the 4th Annual Northwest Biomechanics Symposium, May 9-10, 2008, Boise, ID, USA

Greaves CY, Saari A, Cripton PA. A method for estimating stresses in spine fixators in vivo. Proceedings of the 4th Annual Northwest Biomechanics Symposium, May 9-10, 2008, Boise, ID, USA

Ming K, Abugharbieh R, Jones CF, Yung A, Kozlowski P, Tetzlaff W, Cripton PA, Computational MR Image Analysis for Spinal Cord Injury Studies. Proceedings of the International Society for Magnetic Resonance in Medicine (ISMRM) 16th Scientific Meeting & Exhibition, May 3-9, 2008, Toronto, Canada

Manske SL, de Bakker PM, Ebacher V, Oxland TR, Cripton PA, Guy P, Failure in femoral neck fractures initiates in the superolateral cortex: evidence from high speed video of simulated fractures. Proceedings of the 54th Annual Meeting of the Orthopaedic Research Society, March 2-5 2008, San Francisco, California

Saari A, Dennison C, Wild P, Wilson DA, Cripton PA, Intervertebral disc pressure during lateral bending. Proceedings of the 54th Annual Meeting of the Orthopaedic Research Society, March 2-5 2008, San Francisco, California

Dennison C, Saari A, Wild P, Wilson DA, Cripton PA, Comparison of intervertebral disc pressure measurements made with fibre-Bragg gratings to those made with a contemporary needle mounted sensor ex vivo. Proceedings of the 54th Annual Meeting of the Orthopaedic Research Society, March 2-5 2008, San Francisco, California

Saari A, Dennison C, Wild P, Wilson DA, Cripton PA, Intervertebral disc pressure measurements: Influence of disc thickness on disc pressure during lateral bending. World Forum for Spine Research, January 23-26, 2008. Kyoto, Japan.

Dennison C, Saari A, Wild P, Wilson DA, Cripton, PA, Ex vivo measurement of porcine intervertebral disc pressure during compression and lateral bending using a novel in-fibre Bragg grating sensor. World Forum for Spine Research, January 23-26, 2008. Kyoto, Japan

Beadon K., Siggers K., Johnston J.D., Itshayek E., Cripton P.A. Biomechanical Simulation of Spondylolysis and Spondylolisthesis: An In Vitro Porcine Model. Proceedings of the 34th Annual Meeting of the International Society for the Study of the Lumbar Spine, June 10-14, 2007, Hong Kong, China

Zhu, Q., Park, Y., Sjovold, S.G., Niosi, C.A., Wilson, D.C., Cripton, P.A., Oxland, T.R. Can extra-articular strains be used to measure facet contact forces in the lumbar spine? Proceedings of the 34th Annual Meeting of the International Society for the Study of the Lumbar Spine, June 10-14, 2007, Hong Kong, China

deBakker P.M., Manske S.L., Oxland T., Cripton P.A., Guy P. Failure in Femoral Neck Fractures Initiates in the Superolateral Cortex: Evidence from High Speed Video of a Simulated Fracture. Proceedings of the Canadian Orthopaedic Research Society, June 1-3, 2007, Halifax, NS,

Peter A. Cripton, Ph.D. Page 14 10/13

Beadon K., Johnston J.D., Siggers K., Itshayek E., Cripton P.A. A Repeatable In Vitro Biomechanical Model of Spondylolysis and Spondylolisthesis. Proceedings of the 3rd Annual Northwest Biomechanics Symposium, May 18-19, 2007, Eugene, OR, USA

Boak J.C., Popovic D., Koenig L., Dvorak M., Cripton P.A. Cervical spondylosis and range of motion in the geriatric population: methodology and preliminary results. Proceedings of the 3rd Annual Northwest Biomechanics Symposium, May 18-19, 2007, Eugene, OR, USA

Nelson T.S., Cripton P.A. Methodology for evaluating a neck injury prevention helmet. Proceedings of the 3rd Annual Northwest Biomechanics Symposium, May 18-19, 2007, Eugene, OR, USA

Greaves L.L., Cluff M., Greaves C.Y., Zhu Q., Melnyk A., Perdios A., Tredwell S., Mulpuri K., Cripton P. The Effect of Age and Gender on the Three-Dimensional Kinematics of the Pediatric Cervical Spine. Proceedings of the 3rd Annual Northwest Biomechanics Symposium, May 18-19, 2007, Eugene, OR, USA

Ming K., Abugharbieh R., Jones C.F., Yung A., Tetzlaff W., Kozlowski P., and Cripton P.A. In vivo MR image based deformation analysis for spinal cord injury studies. Proceedings of the 3rd Annual Northwest Biomechanics Symposium, May 18-19, 2007, Eugene, OR, USA

Messenberg A., Vorrink S., Hughes B., Sawatzky B., Cripton P.A. Influence of Wheel Design on Wheelchair Vibration; Correlation as a trigger of muscle spasms. Proceedings of the 3rd Annual Northwest Biomechanics Symposium, May 18-19, 2007, Eugene, Oregon, USA

Larson C.R., Zhu Q.A., Itshayek E., Dvorak M.F., Fisher C.G., Cripton P.A. Screw loading of the TSRH SAS spinal system in cadaveric simulated deformity correction. Proceedings of the Canadian Spine Society Annual Meeting, March 21-24, 2007, Mt. Tremblant, PQ, Canada

Itshayek E., Saari A., Nelson T.S., Heran M, Jhamb A., Cripton P.A. Spinal cord deformation, expected neurologic injury, clinical classification of column injury and residual compression resulting from head-first impact: a high–speed experiment. Proceedings of the Canadian Spine Society Annual Meeting, March 21-24, 2007, Mt. Tremblant, PQ, Canada

Saari A., Itshayek E., Nelson T.S., Cripton P.A. Kinematics of the entire cervical spine in the presence of physiologic follower load during head-first impact. Proceedings of the Canadian Spine Society Annual Meeting, March 21-24, 2007, Mt. Tremblant, PQ, Canada

Saari A., Itshayek E., Nelson T.S., Cripton P.A. High speed cineradiographic measurment of spinal cord deformation during cervical spine injuries in a cadaver model. Proceedings of the Canadian Spine Society Annual Meeting, March 21-24, 2007, Mt. Tremblant, PQ, Canada

deBakker P.M., Manske S.L., Ebacher V., Guy P., Oxland T., Cripton P.A. Failure in Femoral Neck Fractures Initiates in the Superolateral Cortex: Evidence from High Speed Video of a Simulated Fracture. Proceedings of the Alberta Biomedical Engineering Conference, October 21-22, 2006, Banff, AB, Canada Saari A., Itshayek E., Nelson T.S., Morley P.L., Cripton P.A. Spinal cord deformation during injury of the cervical spine in head-first impact. Proceedings of the International Research Council on the Biomechanics of Impacts - 2006 Annual Meeting, September 20-22, 2006, Madrid, Spain (4 page conference manuscript).

Peter A. Cripton, Ph.D. Page 15 10/13

Levesley M., Cripton P.A. An Application of Remotely Controlled Experiments to Perform Feedback-Damping Control of a Vibrating Beam. Proceedings of the Second International Association of Science and Technology for Development, International Conference on education and technology, July 17-19, 2006, Calgary, AB, Canada

Larson C.R., Zhu Q.A., Sjovold S.G., Rosler D.M., Keynan O., Wilson D.R., Cripton P.A., Oxland T.R. Kinematic Behaviour Of The Implanted Total Facet Arthroplasty System™: An In Vitro Model. Proceedings of the Annual Meeting of the International Society for the Study of the Lumbar Spine, June 13-17, 2006, Bergen, Norway

Sjovold S.G., Zhu Q., Larson C.R., de Bakker P.M., Oxland T.R., Cripton P.A. Comparative loading of the total facet arthroplasty systemtm with a rigid posterior instrumentation system and intact facets. Proceedings of the Annual Meeting of the International Society for the Study of the Lumbar Spine, June 13-17, 2006, Bergen, Norway

Jones C.F., Reed S.G., Cripton P.A., Hall R.M. The effect of cerebrospinal Fluid on Spinal Cord Deformation in an in vitro Burst Fracture Model. Proceedings of the 2nd Annual Ohio Injury Biomechanics Symposium, May 17-19, 2006, Columbus, OH, USA (10 page manuscript in proceedings)

Nelson T.S., Cripton P.A. A Kinematically biofidelic surrogate cervical spine for axial compressive impacts. Proceedings of the 2nd Annual Ohio Injury Biomechanics Symposium, May 17-19, 2006, Columbus, OH, USA (10 page manuscript in proceedings)

Johnston J., Beadon K., Siggers K., Cripton P.A. Biomechanical simulation of spondylolysis and spondylolisthesis:an in vitro porcine model. Proceedings of the 2nd Annual Northwest Biomechanics Symposium, May 12-13, 2006, Vancouver, BC, Canada

Greaves C.Y., Cripton P.A., Berlemann U., Dumas G.A., Nolte L.P. Failure load and strain distribution in the human cervical spine during destructive axial loading. Proceedings of the 2nd Annual Northwest Biomechanics Symposium, May 12-13, 2006, Vancouver, BC, Canada

Nelson T.S., Cripton P.A. A biofidelic surrogate neck for axial compressive impacts. Proceedings of the 2nd Annual Northwest Biomechanics Symposium, May 12-13, 2006, Vancouver, BC, Canada

Dennison C.R., Wild P.M., Wilson D.R., Cripton P.A. Bovine disc pressure measurement using fibre-bragg gratings. Proceedings of the 2nd Annual Northwest Biomechanics Symposium, May 12-13, 2006, Vancouver, BC, Canada

Jones C.F., Reed S.G., Cripton P.A., Hall R.M. High speed transverse compression of an in vitro spinal cord/cerebrospinal fluid model. Proceedings of the 2nd Annual Northwest Biomechanics Symposium, May 12-13, 2006, Vancouver, BC, Canada

Saari A., Cripton P.A. Cervical spinal cord deformation during head to ground impact induced injuries. Proceedings of the 2nd Annual Northwest Biomechanics Symposium, May 12-13, 2006, Vancouver, BC, Canada

Louman-Gardiner K., Mulpuri K., Perdios A., Tredwell S., Cripton P.A. Lumbar spine biomechanics of pediatric chance fractures: recommendations for injury prevention. Proceedings of the 2nd Annual Northwest Biomechanics Symposium, May 12-13, 2006, Vancouver, BC, Canada

Peter A. Cripton, Ph.D. Page 16 10/13

Boak J.C., Lau C., Bellezza A.J., Saari A. Projectile parameters that cause ocular injury during impact, Proceedings of the 2nd Annual Northwest Biomechanics Symposium, May 12-13, 2006, Vancouver, BC, Canada

Saari A., Cripton P.A. Dynamic response of the cervical spine in the presence of physiologic follower load during head to ground impact. Proceedings of the 2nd Annual Northwest Biomechanics Symposium, May 12-13, 2006, Vancouver, BC, Canada

Rundell S.A., Bowden A.E., Villarraga M.L., Zhu Q., Cripton P.A. Validation of experimental implant-bone interface load measurements for a facet replacement device using finite element analysis. Proceedings of the Spine Arthroplasty Society 6, May 10-13, 2006, Montreal, Canada.

Louman-Gardiner K., Mulpuri K., Perdios A., Tredwell S., Cripton P.A. Pediatric chance fractures and associated injuries in British Columbia: Recommendations for Injury Prevention. Accepted for presentation at the BC Injury Research Conference, March 1-3, 2006, Vancouver BC, Canada

Cripton P.A. Biomechanical Evaluation of Motion Preserving Spine Implants. Artificial Disc Workshop at the Orthopaedic Research Society Annual Meeting, March 19, 2006, Chicago IL, USA

Wild P.M., Dennison C.R., Wilson D.R., Wilson D.C., Zhu Q.A., Byrnes P.W., Cripton P.A. Measurement of Lumbar Disc Pressure using Fiber Bragg Gratings. Accepted for presentation at the 52nd Annual Meeting of the Orthopaedic Research Society, March 19-22, 2006, Chicago IL, USA

Cripton P.A. Dynamic stabilization techniques: biomechanics. AOSPINE degenerative lumbar spine and deformity course, December 12, 2005, Davos, Switzerland

Cripton P.A. Biomechanics of internal fixation. AOSPINE degenerative lumbar spine and deformity course, December 12, 2005, Davos, Switzerland

Saari A., Morley P., Cripton P.A. Burst fractures of the cervical spine in the presence of physiologic preload: reconstruction of three dimensional kinematics. Proceedings of the International Collaboration on Repair Discoveries (ICORD) Annual Research Meeting, October 17, 2005, Vancouver BC, Canada

Louman-Gardiner K., Mulpuri K., Perdios A., Tredwell S., Cripton P.A. Pediatric chance fractures and associated neurological injury in British Columbia: recommendations for injury prevention. Proceedings of the International Collaboration on Repair Discoveries (ICORD) Annual Research Meeting, October 17, 2005, Vancouver BC, Canada

Nelson T.S. and Cripton P.A., Strategy for prevention or mitigation of spinal cord injury: a novel helmet for axial compressive crown impacts. Proceedings of the International Collaboration on Repair Discoveries (ICORD) Annual Research Meeting, Canada, October 17, 2005, Vancouver, BC

Reed S.G., Jones C., Hall R.M., Cripton P.A. An In vitro analysis of the behaviour of the bovine and surrogate spinal cords in dynamic transverse compression. Proceedings of the International Collaboration on Repair Discoveries (ICORD) Annual Research Meeting, October 17, 2005, Vancouver BC, Canada

Peter A. Cripton, Ph.D. Page 17 10/13

Schröer B., Messenberg A., Sawatzky B., Huges B., Cripton P.A. Influence of Wheel Design on Wheelchair Vibration; Correlation as a trigger of Muscle Spasms. Proceedings of the International Collaboration on Repair Discoveries (ICORD) Annual Research Meeting, October 17, 2005, Vancouver BC, Canada

Cripton P.A., Babul S. Injury Biomechanics as a means to prevent injuries in Canada. Proceedings of the 2005 Canadian Injury and Prevention Conference, November 6-8, 2005, Halifax NS, Canada

Reed S.G., Bilston L.E., Morley P., Cripton P.A. The human spinal cord: preliminary results for an improved physical model. Proceedings of the 2005 Summer Bioengineering Conference of the American Society of Mechanical Engineers, June 22-26, 2005, Vail CO, USA

Saari A., Morley P., Cripton P.A. Spinal cord deformation during burst fractures of the cervical spine in the presence of physiologic preload. Proceedings of the 2005 Summer Bioengineering Conference of the American Society of Mechanical Engineers, June 22-26, 2005, Vail CO, USA

Reed S.G., Bilston L.E., Morley P., Rankine R., Cripton P.A. A Biofidelic Elastomeric Surrogate for the Human Spinal Cord. Proceedings of the 2005 Northwest Biomechanics Symposium, May 13-14, 2005, Seattle WA, USA

Nelson T., Greaves C., Reed S.G., Rankine R., Cripton P.A. In Vivo Spinal Cord Material Properties: An Indentation Approach. Proceedings of the 2005 Northwest Biomechanics Symposium, May 13-14, 2005, Seattle WA, USA

Saari A., Morley P., Cripton P.A. Spinal Cord Deformation During Burst Fractures Of The Cervical Spine. Proceedings of the 2005 Northwest Biomechanics Symposium, May 13-14, 2005, Seattle WA, USA

Boak J.C., Lau C., Bellezza A., Saari A., Cripton P.A. Ocular Injury Tolerance to Projectile Impacts During Motor Vehicle Collisions. Proceedings of the 2005 Annual Meeting of the Association for Research in Vision and Opthamology, May 1-5, 2005, Fort Lauderdale FL, USA

Larson C.R., Zhu Q., Sjovold S.G., Rosler D.M., Keynan O., Cripton P.A., Oxland T.R. Tissue Loading of the Total Facet Arthroplasty System™ (TFAS™). Proceedings of the Spine Arthroplasty Summit 5, May 4-7, 2005, New York NY, USA

Zhu Q., Larson C.R., Sjovold S.G., Rosler DM, Keynan O, Wilson DR,Cripton P.A., Oxland T.R., Biomechanical Evaluation of the Total Facet Arthroplasty System™ (TFAS™): an in vitro human cadaver model. Proceedings of the 51st Annual Meeting of the Orthopaedic Research Society, February 20 - 23, 2005, Washington D.C., USA

Saari A., Reed S.G., Cripton P.A. A Least Squares Approach to Calculating Angular Acceleration and Velocity Using Accelerometry. Proceedings of the 5th Alberta Biomedical Engineering Conference. October 22-24, Banff AB, Canada.

Reed S.G., Bilston L.E., Morley PL, Cripton P.A. The Human Spinal Cord: An Improved Physical Model. Proceedings of the 5th Alberta Biomedical Engineering Conference, October 22-24, Banff AB, Canada

Peter A. Cripton, Ph.D. Page 18 10/13

Cripton P.A, Zhu Q.A., Wilson D.R., Oxland T.R. Biomechanical evaluation of non-fusion spine implants. Proceedings of the Orthopaedic Research Societies of the USA, Canada, Japan and Europe, October 10-13, 2004, Banff AB, Canada

Tan J.S., Bailey, C.S., Dvorak M.F., Fisher C.G., Cripton P.A., Oxland T.R. Cement augmentation enhances the resistance to subsidence of interbody devices. Proceedings of the Orthopaedic Research Societies of the USA, Canada, Japan and Europe, October 10-13, 2004, Banff AB, Canada

Ramchandani S.R., Panjabi M.M., Cripton P.A., VanderWeele T.J. Biomechanical Examination of Intervertebral Discs Subsequent to Burst Fracture. Proceedings of the 28th Annual Meeting of the American Society of Biomechanics, September 8-11, 2004, Portland OR, USA

Zhu Q.A., Cripton P.A., Wilson D., Niosi C., Wilson D.R., Oxland T.R. Facet Joint Loads in the lumbar spine. Proceedings of the Innovative Techniques In Spine Surgery, August 4-7, 2004, San José del Cabo, Mexico

Cripton, P.A., Dumas, G.A., Nolte, L.P., Helical Axes of Motion of the Sub-Axial Cervical Spine. Proceedings of the 59th Annual Meeting of the Canadian Orthopaedic Research Society, June 18-20, 2004, Calgary AB, Canada

Cripton, P.A., Zhu, Q., Sjovold, S., Larson, C., Kenyan, O., Oxland, T.R. Effect of a Follower Preload on the Helical Axes of motion in the Lumbar Spine. Proceedings of the 2004 Annual Meeting of the International Society for the Study of the Lumbar Spine, May 30-June 5, 2004, Porto, Portugal

Villarraga, M.L., Cripton, P.A., Bellezza, A.J., Kurtz, S.M., Edidin, A.A. The Biomechanical Effects Of Kyphoplasty On Adjacent Non-Treated Vertebral Bodies: A Finite Element Analysis. Proceedings of the 50th Annual Meeting of the Orthopaedic Research Society, March 7 - 10, 2004, San Francisco CA, USA

Villarraga M., Bellezza A., Cripton P.A., Harrigan T., Kurtz S., Edidin A. Biomechanical Evaluation of Kyphoplasty on Treated and Adjacent Vertebral Bodies, Poster P422. Proceedings of the 71st Annual Meeting of the American Academy of Orthopaedic Surgeons, March 10-14, 2004, San Francisco CA, USA

Villarraga M.L., Kurtz S.M., Cripton P.A., Edidin A.A. The Biomechanical Effects of Kyphoplasty on Single Thoraco-Lumbar Vertebrae: A Parametric Finite Element Analysis. Proceedings of the 49th Annual Meeting of the Orthopaedic Research Society, February 2–5, 2003, New Orleans LA, USA; v. 28: 29,

Villarraga M.L., Cripton P.A., Vaccaro A.R., Hilibrand A.S., Albert T., Turner J., Boatwright J., Smith T. Engineering Analysis of Retrieved Spine Implants. Transactions for the Society for Biomaterials, April 30-May 2, 2003, Reno NV, USA; Vol. 26, p. 669

Villarraga, M.L., Kurtz S.M., Cripton P.A., Edidin A.A. The Biomechanical Effects Of Kyphoplasty On Single Thoraco-Lumbar Vertebrae: A Parametric Finite Element Analysis. Proceedings of the 49th Annual Meeting of the Orthopaedic Research Society, February 2-5, 2003, New Orleans LA, USA

Peter A. Cripton, Ph.D. Page 19 10/13

Ivancic P.C., Panjabi M.M., Ito S., Cripton P.A., Wang J.L. A Biofidelic Osteoligamentous Cervical Spine Model with Muscle Force Replication for Whiplash Trauma Simulation. Proceedings of the thirtieth Annual Meeting of the Cervical Spine Research Society, December 5-7, 2002, Miami FL, USA

Vaccaro A.R., Villarraga M.L., Cripton P.A., Albert T.J., Hilibrand A.S. Improvement of Spine Implant Performance Through Analysis of Retrieved Implants. Proceedings, Thirtieth Annual Meeting of the Cervical Spine Research Society, December 5-7, 2002, Miami FL, USA

Cripton P.A., Villarraga M.L., Vaccaro A.R., Hilibrand A.S., Albert T.J., Turner J.L., Daffner S.D., Smith T.R. Analysis of Retrieved Scoliosis Instrumentation. Proceedings, Thirty Seventh Annual Meeting of the Scoliosis Research Society, September 19-22, 2002, Seattle WA, USA

Ford Corrigan C., Cripton P.A., Croteau J. The Influence Of Vehicle Roll Rate On Neck Loading During Controlled Vehicle-To-Ground Impacts. Proceedings of the Fourth World Congress of Biomechanics, August 4-9, 2002, Calgary AB, Canada

Cripton P.A., Anterior and Posterior Spinal Fixation - An In Vitro Summary. Proceedings of the Fourth World Congress of Biomechanics, August 4-9, 2002, Calgary AB, Canada

Turner J.L., Boatwright J.R., Vaccaro A.R., Hilibrand A.S., Albert T.J., Villarraga M.L., Cripton P.A. Improvement of Spine Implant Performance through Analysis of Retrieved Implants: Preliminary Results. Proceedings of the 28th Annual Northeast Bioengineering Conference, April 20-21, 2002, Philadelphia PA, USA

Miura T., Panjabi M.M., Cripton P.A. Stabilizing Potential of Lateral Mass Plates in Anterior Cervical Fusions Without Anterior Plating. Proceedings of the 29th Annual Meeting of the Cervical Spine Research Society, November 29-December 2, 2001, Monterey CA, USA

Cripton P.A., Miura T., Panjabi M.M. The Role of Bone Graft Force in Anterior Cervical Strut Grafting Without Anterior Plating. Proceedings of the 29th Annual Meeting of the Cervical Spine Research Society, November 29-December 2, 2001, Monterey CA, USA

Miura T., Panjabi M.M., Cripton P.A. Stability of Three Strut-Graft Constructs for Multi-Level Cervical Corpectomy. Proceedings of the 29th Annual Meeting of the Cervical Spine Research Society, November 29-December 2, 2001, Monterey CA, USA

Cripton P.A., Miura T., Panjabi M.M. Bone graft force in anterior cervical fusions without anterior plating. Proceedings of the 16th Annual Meeting of the North American Spine Society, Oct 31 – Nov 3, 2001, , Seattle WA, USA

Panjabi M.M., Miura T., Cripton P.A., Wang J, Nain A.S. Neck muscle force replication for in vitro whole cervical spine experiments. Proceedings of the 47th Annual Meeting of the Orthopaedic Research Society, Feb 25-28, 2001, San Francisco CA, USA

Berdia S., Panjabi M.M., Cripton P.A., Dodds S., Baynes J., Wolfe S.W. External fixation of the wrist: Using neutral zone as a marker for overdistraction. Proceedings of the 47th Annual Meeting of the Orthopaedic Research Society, Feb 25-28, 2001, San Francisco CA, USA

Cripton P.A., Läubli R., Berlemann U., Dumas G.A., Nolte L.-P. Force Transmission In The Human Cervical Spine During Destructive Axial Compression: Effect of Flexion and Extension Postures. Proceedings of the 28th Annual Meeting of the Cervical Spine Research Society, Nov 30-Dec 2, 2000, Charleston SC, USA

Peter A. Cripton, Ph.D. Page 20 10/13

Cripton P.A., Miura T., Panjabi M.M. The Effects of Physiologic Compressive Preload On the In Vitro Flexibility of the Lower Cervical Spine. Proceedings of the 28th Annual Meeting of the Cervical Spine Research Society, Nov 30-Dec 2, 2000 Charleston SC, USA

Panjabi M.M., Miura T., Cripton P.A., Wang J.-L., Nain A.S. Development Of A System For In Vitro Neck Muscle Force Replication In Whole Cervical Spine Experiments. Proceedings of the 28th Annual Meeting of the Cervical Spine Research Society, Nov 30-Dec 2, 2000, Charleston SC, USA

Miura T., Panjabi M.M., Cripton P.A. A Method to Simulate In vivo Cervical Spine Kinematics Using Compressive Preload In vitro. Proceedings of the 28th Annual Meeting of the Cervical Spine Research Society, Nov 30-Dec 2, 2000, Charleston SC, USA

Orr T.E., Beutler T., Cripton P.A., Nolte L.P., Haberl, H. The role of facet joints in axial torsion with and without superimposed extension/flexion moments. Proceedings of the 27th Annual Conference of the International Society for the Study of the Lumbar Spine, April 9-13, 2000, Adelaide, Australia; Pg. 53.

Orr T.E., Beutler T., Cripton P.A., Nolte L.P. and Haberl H. The Role of Facet Joints on the Helical Axis of Motion in Axial Torsion With and Without Superimposed Extension/Flexion Moments. Proceedings of the 12th conference of the European Society of Biomechanics, August 27-30 2000, Dublin Ireland; Pg. 175.

Cripton P.A., Dumas G.A., and Nolte L.-P. Biomechanics of the human cervical spine under shear loading: effect of superimposed compression forces. Proceedings of the 1999 Annual Meeting of the Spine Society of Europe, September 7-11, 1999, Munich, Germany; European Spine Journal. 8(supplement 1):s6.

Cripton P.A., Dumas G.A., and Nolte L.-P. Compressive force transmission in the human cervical spine: effect of superimposed flexion and extension postures. Proceedings of the 9th Conference of the European Orthopaedic Research Society, June 3-4, 1999, Brussels, Belgium; Pg. O 67.

Cripton P.A., Bruehlmann S.B., Orr T.E., Oxland T.R., Nolte L.-P. Common axial preload application methods produce large artefacts in moment, shear and kinematics during flexibility testing. Proceedings of the 26th Annual Conference of the International Society for the Study of the Lumbar Spine, June 21-25, 1999, Kona, Hawaii

Cripton P.A., Bourquin Y., Sati M., Orr T.E., Dumas G.A., Nolte, L.-P. Animation of in vitro Biomechanical Tests. Proceedings of the 4th International Symposium on Computer Assisted Orthopaedic Surgery, March 17-19, 1999, Davos, Switzerland

Cripton P.A., Dumas G.A., and Nolte L.-P. Compressive force transmission in the human cervical spine: effect of superimposed moments. Proceedings of the 45th Annual Meeting of the Orthopaedic Research Society, Feb. 1-4, 1999, Anaheim CA, USA

Bruehlmann S.B., Cripton P.A., Orr T.E., Oxland T.R., and Nolte L.-P. Axial preload application during spine flexibility testing: a quantitative comparison of four methods. Proceedings of the 45th Annual Meeting of the Orthopaedic Research Society, Feb. 1-4, 1999, Anaheim CA, USA

Peter A. Cripton, Ph.D. Page 21 10/13

Cripton P.A., Dumas G.A., and Nolte L.-P Moment and force transmission in the human cervical spine. Proceedings of the 1st Conference of the German Society of Biomechanics, February 26-27, 1999, Ulm, Germany

Grants (2008-present)

Granting Agency

Subject COMP $ Per Year

Years Principal Investigator

Co-Investigator(s)

Medtronic Inc.

Load Transfer Characteristics between Posterior Implant and the Lumbar Spine in

Shear – A Biomechanical Investigation

NC 88,500 (US)

2009 2010

T.R. Oxland P.A. Cripton,Q. Zhu, M. Dvorak, S. Kingwell, A.

Melnyk

Whistler Sport

Legacies Society

Whistler Sliding Centre Sled Trajectory

Evaluation - Trauma Study

C 93,556 2011 P.A. Cripton

NSERC (Idea to

Innovation)

A helmet to prevent spinal cord injuries

during head first impact

C 55,952 (CDN)

2007 2008

P.A. Cripton

CIHR (Operating

Grant)

The role of cerebrospinal fluid and the

subarachnoid space in acute spinal cord injury

C 72,088 (CDN)

2007 2008 2009 2010

P.A. Cripton B.K. Kwon

Heart and Stroke

Foundation of Canada

Bicyclists’ injuries and the cycling environment

(The BICE Study)

C 193,000 (CDN)

2008 2009 2010

K. Teschke P.A. Cripton and 14 others

NSERC (Research Tools and

Infrastructure)

Low-pressure, fibre Bragg grating pressure

sensors for measurement of cerebrospinal fluid

pressures associated with spinal cord injury

C 56,672 (CDN)

2008 P.A. Cripton P Wild

CIHR (Catalyst Grant)

Brain activation: From mechanisms to mobility

C 73,940 (CDN)

2008 J. Eng P.A. Cripton and one other

Peter A. Cripton, Ph.D. Page 22 10/13

NSERC (Discovery

Grant)

Biomechanics of Spinal Cord Injury Throughout

the Lifespan

C 30,000 (CDN)

2009 2010 2011 2012 2013

P.A. Cripton

CIHR (Operating

Grant)

Mechanisms of Bone Fracture and their

Clinical Applications

C 127,929 (CDN)

2009 2010 2011 2012

R. Wang P. Guy

P.A Cripton H.A. McKay

CIHR (Proof of Principle)

Pro-Neck-Tor: A helmet to prevent spinal cord

injuries occurring during sports and transportation

C 74,876 (CDN)

2009 2010

P.A. Cripton J. Street

Congress- Directed Medical Research Program

(Dept of the US Army)

Vibration and shock exposure limits for

transport of the acute spinal cord injured

C 2,348,595 Total (US)

2011 2012 2013

P.A. Cripton B. Kwon, K. Barazanji, R. Kinsler, D. Wilder, S. Rahmatalla

NSERC (Discovery

Grant)

Using Biomechanical Engineering to Prevent

Spinal Cord Injuries

C 31,000 (CDN)

2012 2013 2014 2015 2016

P.A. Cripton

CIHR (Operating

Grant)

Towards a Cervical Spine Injury Tolerance

Criterion that incorporates Lateral

Bending Loading

C 135,757 (CDN)

2012 2013 2014 2015

P.A. Cripton T.R. Oxland J. Street

Note: CIHR = Canadian Institutes of Health Research, NSERC = Natural Sciences and Engineering Research Council of Canada

Patents and Intellectual Property Rights

Pressure Sensor for Biological Fluids and Use Thereof, US Provisional Patent Application 60/776,600 Filing Date: February 23, 2006 (I am one of five inventors)

Protective helmet with movable outer shell relative to inner shell, US Patent 8,156,569 Issued: April 17, 2012 (I am one of two inventors on the patent)