Penetration - Bitumen Method - PNR 12 (automatic) group(s): Bitumen, Penetration ... (Except for the...

7
Page: 1 01.07.2009 18-1120_Bitumen.pdf data & photo not mandatory Penetration - Bitumen Method - PNR 12 (automatic) Standards depend on the selected accessories ASTM D 5, DIN 52010 (obs.), EN 1426, EN 13179-2, EN 13880-2, JIS K2207, AASHTO T49 Product group(s): Bitumen, Penetration User group(s): Airports & Aviation, Asphalt, Bitumen, Mastics, Penetration, Regulatory Authorities, Road Research, Tar, Various Scope: The Penetrometer PNR 12 is suitable for measurements according various "Bitumen" methods. Needle-Penetration: To measure the consistancy of semi-solid and solid bituminous mixtures. Rod-Penetration: To measure the apparent viscosity (Bitumen No) of filler aggregates used in bituminous mixtures. Cone-Penetration: To determinate the consistancy of hot-applied, fuel-resistant joint sealants with or with out being immersed in fuel or oil. The Penetration is used to measure the resistance which a material under specified test conditions provides against being pierced by a specifically shaped penetrator. Fully "Automatic Surface-Detection" on bitumen beneath a standardized layer of water Jog-Shuttle driven menue (turn & push) Movement by stepper motor LED illumination Beside the configuration of the penetrator used, prime importance attaches to such factors as temperature, time and load specified by the different standard methods of test. PNR 12 - Automatic Penetrometer Depending on accessories suitable for: • Needle-Penetration • Cone-Penetration • Rod-Penetration • and further applications Accessories (plungers, needles etc.) are required, but not included. All test kits that fit the PNR 10 & 21 models are suitable for the PNR 12, too. (Except for the Ball-Penetration Method) More details are mentioned in the "Order Number" section Technical Data Measuring Range: 0 to 55 mm Max. Test Load: 2 kg Resolution: 0.01 mm Test Duration: 0.1 to 9999.9 seconds (preset standard duration: 5 seconds) Start Delay: adjustable up to max. of 9999.9 sec. (2.78 hours) Data Output: USB interface to connect printer or USB-stick 0-Point Detector: for electrically conductive samples Desk space (WxHxD): 350 x 400 x 600 mm Weight: 16 kg

Transcript of Penetration - Bitumen Method - PNR 12 (automatic) group(s): Bitumen, Penetration ... (Except for the...

Page 1: Penetration - Bitumen Method - PNR 12 (automatic) group(s): Bitumen, Penetration ... (Except for the Ball-Penetration Method) ... bituminous materials, chocolate, ...

Page: 101.07.2009

18-1120_Bitumen.pdfdata & photo not mandatory

Penetration - Bitumen Method - PNR 12 (automatic)Standards depend on the selected accessories

ASTM D 5, DIN 52010 (obs.), EN 1426, EN 13179-2, EN 13880-2, JIS K2207, AASHTO T49

Product group(s): Bitumen, Penetration

User group(s): Airports & Aviation, Asphalt, Bitumen, Mastics, Penetration, Regulatory Authorities, Road Research, Tar,Various

Scope: The Penetrometer PNR 12 is suitable for measurements according various "Bitumen" methods.

Needle-Penetration:To measure the consistancy of semi-solid and solid bituminous mixtures.

Rod-Penetration:To measure the apparent viscosity (Bitumen No) of filler aggregates used in bituminous mixtures.

Cone-Penetration:To determinate the consistancy of hot-applied, fuel-resistant joint sealants with or with out being immersed infuel or oil.

The Penetration is used to measure the resistance which a materialunder specified test conditions provides against being pierced by aspecifically shaped penetrator.

Fully "Automatic Surface-Detection" on bitumen beneath astandardized layer of waterJog-Shuttle driven menue (turn & push)

Movement by stepper motor

LED illumination

Beside the configuration of the penetrator used, prime importanceattaches to such factors as temperature, time and load specified bythe different standard methods of test.

PNR 12 - Automatic Penetrometer

Depending on accessories suitable for:

• Needle-Penetration • Cone-Penetration• Rod-Penetration • and further applications

Accessories (plungers, needles etc.) are required, but not included.All test kits that fit the PNR 10 & 21 models are suitable for the PNR 12, too.(Except for the Ball-Penetration Method)

More details are mentioned in the "Order Number" section

Technical Data

Measuring Range: 0 to 55 mmMax. Test Load: 2 kgResolution: 0.01 mmTest Duration: 0.1 to 9999.9 seconds

(preset standard duration: 5 seconds)Start Delay: adjustable up to max. of 9999.9 sec.

(2.78 hours)Data Output: USB interface to connect printer or USB-stick0-Point Detector: for electrically conductive samplesDesk space (WxHxD): 350 x 400 x 600 mmWeight: 16 kg

Page 2: Penetration - Bitumen Method - PNR 12 (automatic) group(s): Bitumen, Penetration ... (Except for the Ball-Penetration Method) ... bituminous materials, chocolate, ...

Page: 201.07.2009

18-1120_Bitumen.pdfdata & photo not mandatory

Main Unit

18-1120 PNR 12 - Automatic PenetrometerAccessories have to be selected according to the standard. (Suitable for: Needle-, Cone-, Rod-Penetration and further methods)

Features: • manual positioning by Jog-Wheel operation • electronic positioning to a preset depth with Memory-function • surface detection by conductivity sensor • 16 user programs possible • data transfer to USB-Stick possible • extra bright LED-sample illumination

Consisting of:Microcomputer, electronic distance measuring device, stepper motor for exact positioning, 24 V safetyvoltage supply, stable base plate and housing.

Microcomputer:Large graphical monochrome display, intuitive graphical menu, status feedback to operator, Jog-Wheeldriven menu (turn & push), storage of last 200 measurements.

The Surface-Detection Software of the PNR 12 will be activated by sensor-plungers. This option willdetect the surface of bitumen-samples underneath a layer of water, it starts the standardized testsequence and reports the results automatically.

Electronic Elements:Distance measuring device (1/100 mm), stepper motor, ultra bright LED-sample illumination on flexiblearm, electronic detector for conductive samples, USB-interface for printer & memorystick.

Mechanical Elements:Penetrometer base plate with leveling feet and removable aluminum test table, instrument housingtwo colored powder coated, splash water protected membrane keyboard, plunger holder with solenoidrelease mechanism and observation lens with fl exible arm.

Note: Accessories in compliance with the different test standards or samples (e.g. needles, cones, plunger etc.) are to be ordered separately.

Power supply: 100/240 V, 50/60 Hz

18-2220 Test Kit "Needle - ASTM"ASTM D 5 - AASHTO T49 - JIS K2207

Suitable for: bituminous materials, chocolate, compact powder, lipstick, soap, yeast

Consisting of: 3 standard needles, 2.5 g, brass/steel, precision made (18-1160) 1 plunger 47.5 g (18-0042) 1 load weight 50 g (18-0051) 5 sample jars I, Ø 55 x 35 mm (18-0066) 1 tempering bath (18-0065)1 petri dish, Ø 43 x 11 mm (13-0514)

18-2221 Test Kit "Needle - EN"EN 1426 (IP 49 obs.)

Suitable for: bituminous materials, chocolate, compact powder, lipstick, soap, yeast

Consisting of: 3 standard needles 2.5 g, brass/steel, precision made (18-1160) 1 plunger 47.5 g (18-0042) 1 load weight 50 g (18-0051) 5 sample jars I, Ø 55 x 35 mm (18-0066) 1 sample jar III, Ø 70 x 45 mm (18-0068) 1 sample jar V, Ø 55 x 60 mm (18-0069) 1 reduction ring Ø 36 / 53 x 20 mm (18-0076) 1 reduction ring Ø 36 / 53 x 30 mm (18-0077) 1 tempering bath with serpentine heat exchanger tube (18-0070) 1 intermediate bottom (18-0091) 1 thermometer holder (18-0094)

Page 3: Penetration - Bitumen Method - PNR 12 (automatic) group(s): Bitumen, Penetration ... (Except for the Ball-Penetration Method) ... bituminous materials, chocolate, ...

Page: 301.07.2009

18-1120_Bitumen.pdfdata & photo not mandatory

1 thermometer ASTM 63C (90-0106) 1 thermometer ASTM 64C (90-0107)

Note! for standard acc. to IP 49 obs. is required: 150g load weights (18-0052 & 18-0056) and thermometer ASTM 17C (21-0601).

18-2222 Test Kit "Needle - manually <350 PU"

ASTM D 5 (<350 PU) - EN 1426 (<330 PU)

Suitable for: Bitumenwith an expected immersion depth of less than 35 mm

Consisting of:3 standard needles 2.5 g, brass/steel, precision made (18-1160)1 plunger 97.5 g (18-0050)3 sample jars I, Ø 55 x 35 mm (18-0066)1 sample jar III, Ø 70 x 45 mm (18-0068)1 tempering bath (Ø 160 x 80 mm) with serpentine heat exchanger tube (18-0070)1 intermediate bottom (18-0091)1 thermometer holder (18-0094)1 thermometer ASTM 63C (90-0106)

Note! for manual surface detection with PNR 12

18-2223 Test Kit "Needle - automatic <160 PU"

ASTM D 5 (<160 PU) - EN 1426 (<160 PU)

Suitable for: Bitumenwith an expected immersion depth of less than 16 mmafter 5 seconds with 100 g weight

Consisting of:3 standard needles 2.5 g, brass/steel, precision made (18-1160)1 sensor plunger 97.5 g (18-1136)3 sample jars I, Ø 55 x 35 mm (18-0066)1 tempering bath (Ø 160 x 80 mm) with serpentine heat exchanger tube (18-0070)1 intermediate bottom (18-0091)1 thermometer holder (18-0094)1 temperature sensor PT-100 (18-1149)

Note! for automatic surface detection with PNR 12 only!

18-2224 Test Kit "Needle - manually >330 PU"

ASTM D 5 (>350 PU) - EN 1426 (>330 PU)

Suitable for: Bitumenwith an expected immersion depth of more than 33 mm

Consisting of:3 long standard needles 2.5 g, brass/steel, precision, (18-9994)1 plunger 97.5 g (18-0050)3 sample jars I, Ø 55 x 70 mm (18-0075)1 tempering bath (Ø 160 x 80 mm) with serpentine heat exchanger tube (18-0070)1 intermediate bottom (18-0091)1 thermometer holder (18-0094)1 thermometer ASTM 63C (90-0106)

Note! for manual surface detection with PNR 12

18-2225 Test Kit "Needle - automatic <160 PU modified"

ASTM D 5 (<160 PU)

Suitable for: modified Bitumenwith an expected immersion depth of less than 16 mmafter 60 seconds with 200 g weight

Consisting of:3 standard needles 2.5 g, brass/steel, precision made (18-1160)1 sensor plunger 97.5 g (18-1136)

Page 4: Penetration - Bitumen Method - PNR 12 (automatic) group(s): Bitumen, Penetration ... (Except for the Ball-Penetration Method) ... bituminous materials, chocolate, ...

Page: 401.07.2009

18-1120_Bitumen.pdfdata & photo not mandatory

1 load weight, 100 g (18-1201)3 sample jars I, Ø 55 x 35 mm (18-0066)1 tempering bath (Ø 160 x 80 mm) (18-0065)1 intermediate bottom (18-0091)1 thermometer holder (18-0094)1 temperature sensor PT-100 (18-1149)

Note! for automatic surface detection with PNR 12 only!

18-2370 Test Kit "Ram - Bitumen Number" (van der Baan)EN 13 179-2

Suitable for: bitumen

Consisting of: 1 ram Ø 8 mm, 15 g, aluminum (18-0251) 1 sample jar Ø 30 mm x 30 mm (18-0252)

18-2215 Test Kit "Optional Hollow Cone - Filler"ASTM D 5329 - EN 13 880-2

Suitable for: Sealant, Fillers

Consisting of: 1 optional hollow cone 102.5 g, brass/steel (18-0101) 1 plunger 47.5 g (18-0042) 1 sample jar I, Ø 55 x 35 mm (18-0066) 1 tempering bath (18-0065) 1 spacer plate for tempering bath (18-0091)

Options & Accessories

18-1160 Standard Needle, 2.5 g (precision made)ASTM D 5 - EN 1426 - JIS K2207 (lP 49 obs.) and other applications

made of brass / stainless steel

18-1161 Standard Needle, 2.5 g (factory certified)ASTM D 5 - EN 1426 - JIS K2207 (lP 49 obs.) and other applications

made of brass / stainless steel

18-1163 Standard Needle, 2.5 g (officially certified)EN 1426 (lP 49 obs.)

made of brass / stainless steel

18-1164 Standard Needle, 2.5 g (officially certified)ASTM D 5 (suitable for EN 1426 and lP 49 obs.)

made of brass / stainless steel

18-1135 Sensor-Plunger - Force 47.5 g (PNR 12 only)1 load weight of 2/5/10/50 or 100 g can be added.

(Same like 18-1136)

18-1136 Sensor-Plunger - Force 97.5 g (PNR 12 only)1 load weight of 2/5/10/50 or 100 g can be added.

A plunger with an extremely sensitive force sensor for the automatic surface detection underneath alayer of water.It activates the related the PNR 12 software automatically.

Suitable for Bitumen-samples <160 PU!

Page 5: Penetration - Bitumen Method - PNR 12 (automatic) group(s): Bitumen, Penetration ... (Except for the Ball-Penetration Method) ... bituminous materials, chocolate, ...

Page: 501.07.2009

18-1120_Bitumen.pdfdata & photo not mandatory

18-1137 Sensor-Plunger - Force 97.5 g extra long (PNR 12 only)Up to 4 load weights of 2/5/10/50 or 100 g can be added.

(Same like 18-1136)

18-1200 Additional Weight for Sensor-Plunger, 50 g

18-1201 Additional Weight for Sensor-Plunger, 100 g

18-1202 Additional Weight for Sensor-Plunger, 10 g

18-1203 Additional Weight for Sensor-Plunger, 5 g

18-1204 Additional Weight for Sensor-Plunger, 2 g

25-0282 Serial Impact Printerfor single sheets & continuous paper, with USB-interface to record data like test results, duration of test, etc. (instead of a PC)

Supplied with: 1 data transmission cable, 1 ink ribbon (black)

Technical Data:Line spacing: 80 characters per line (10 cpi)Page size : 257 x 364 mm (sheet), 254 x 558.8 mm (roll)Ports: serial, USB (1.1) & parallelDimensions: 37 x 28 x 16 cm (WxDxH)Weight: 5 kgPower supply: 220/240 V, 50/60 Hz

18-1144 Electronic Stop Watch with electric start-inputPower supply: 100/240 V, 50/60 Hz

18-0712 Halogen Lampextra bright, to be placed beside the penetrometer; especially useful when testing bituminous materialsunder water surface

Power supply: 230 V, 50 Hz

25-0386 Circulator-Bath (internal & external heating & cooling)with intermediate bottom

For tempering applications directly in the bath (e.g. sample pre-tempering) and / or for heating & coolingof instruments without circulation pump (e.g. PNR-tempering dish).

Consisting of:Stainless steel bath with intermediate bottom. Thermostat with analog display, integrated heater, cooler,pump, over-temperature protection, pump-pressure control.

Supplied with: 2 bath covers, 1 pump-set for external tasks, 1 thermometer (0 to +100 : 0.5 °C)

Note: Insulated hose-set is recommended.

Technical Data:Working range: -10 to +100 °C (at +5 to +40 °C ambient temp.)Display / Resolution: analog / 1 °CControl: analogHeater capacity: 1500 WCooling capacity: 250 W at +200 °CPump-Pressure capacity: 17 l/min, 300 mbarBath opening: 30 x 35 x 20 cm (WxDxH)Safety class / Bath fluid: 1 / NFL (water / water-antifreeze-mix only)Volume: 19-26 lDimensions / Weight: 36 x 75 x 40 cm (WxDxH), 31 kgPower supply: 230 V, 50/60 Hz, 2000 W, EU-plug

25-0387 Circulator-Bath (internal & external heating & cooling)

Page 6: Penetration - Bitumen Method - PNR 12 (automatic) group(s): Bitumen, Penetration ... (Except for the Ball-Penetration Method) ... bituminous materials, chocolate, ...

Page: 601.07.2009

18-1120_Bitumen.pdfdata & photo not mandatory

with intermediate bottom

Like 25-0386 but:Heater capacity: 1000 WPower supply: 115 V, 60 Hz, 1500 W

25-0388 Circulator-Bath (internal & external heating & cooling)with intermediate bottom

For tempering applications directly in the bath (e.g. sample pre-tempering) and / or for heating & coolingof instruments without circulation pump (e.g. PNR-tempering dish).

Consisting of:Stainless steel bath with intermediate bottom. Thermostat with digital display, splash-proof keypad,integrated heater, cooler, pump, over-temperature protection, pump-pressure control.

Supplied with: 2 bath covers, 1 pump-set for external tasks

Note: Insulated hose-set is recommended.

Technical Data:Working range: -10 to +100 °C (at +5 to +40 °C ambient temp.)Display / Resolution: LED / 0.1 & 0.01 °CControl: PIDHeater capacity: 2000 WCooling capacity: 250 W at +200 °CPump-Pressure capacity: 17 l/min, 300 mbarBath opening: 30 x 35 x 20 cm (WxDxH)Safety class / Bath fluid: 1 / NFL (Non Flammable Liquids only)Volume: 19-26 lDimensions / Weight: 36 x 75 x 40 cm (WxDxH), 31 kgPower supply: 230 V, 50/60 Hz, 2500 W, EU-plug

25-0389 Circulator-Bath (internal & external heating & cooling)with intermediate bottom

Like 25-0388 but:Heater capacity: 1200 WPower supply: 115 V, 60 Hz, 1700 W

Spare Parts

18-1136 Sensor-Plunger - Force 97.5 g (PNR 12 only)1 load weight of 2/5/10/50 or 100 g can be added.

A plunger with an extremely sensitive force sensor for the automatic surface detection underneath alayer of water.It activates the related the PNR 12 software automatically.

Suitable for Bitumen-samples <160 PU!

18-0705 Electronic surface detector for conductive sampleswith contact hook and connection wire

18-0708 Lampsfor built-in illuminator, 3.7 V; pack of 5, lens shaped

18-0715 Bulb for halogen lamp

25-0284 Ink Ribbon, black, for serial impact printer

21-0601 Thermometer ASTM 17CRange: +19 to +27 : 0.1 °C Length: 275 mm, Immersion: total, Ø 6.5 mm

21-0607 Thermometer ASTM 17CRange: +19 to +27 : 0.1 °C (officially certified)

21-0621 Thermometer ASTM 17FRange: +66 to +80 : 0.2 °F Length: 275 mm, Immersion: total, Ø 6.5 mm

Page 7: Penetration - Bitumen Method - PNR 12 (automatic) group(s): Bitumen, Penetration ... (Except for the Ball-Penetration Method) ... bituminous materials, chocolate, ...

Page: 701.07.2009

18-1120_Bitumen.pdfdata & photo not mandatory

21-0627 Thermometer ASTM 17FRange: +66 to +80 : 0.2 °F (officially certified)

11-0087 Thermometer ASTM 38C / IP 78CRange: +24 to +78 : 0.2 °C Length: 395 mm, Immersion: 100 mm, Ø 7 mm

11-0088 Thermometer ASTM 38C / IP 78CRange: +24 to +78 : 0.2 °C (officially certified)

Order GuidelineMinimum equipment: 1 x 18-1120 & Test Kit (needle, cone etc.),

AccessoriesSpares (approx. 1 year): 18-0708, ThermometerAdditional requirements: