PARKROYAL ON PICKERING Location : 3 Upper Pickering Street, Singapore 058289 Year : 2013 Architect : WOHA Developer : Pan Pacific Hotel Groups Limited Project type : Commercial, Hospitality, Mixed-use, Offices Area : 29,811 sqm The hotel has been awarded the BCA Green Mark Platinum award, the highest rating for green buildings in Singapore for its sustainable design. It is also the recipient of the Solar Pioneer Award as one of the first in the hospitality sector to introduce solar-powered sky- gardens with solar cells that power landscape lighting. PURPOSE OF BUILDING Designed as a hotel and office in a garden, the project at Upper Pickering Street is a study of how we can not only conserve our greenery in a built-up high-rise city centre but multiply it in a manner that is architecturally striking, integrated and sustainable. The building hosts two buildings of different functions. The East wing houses PARKROYAL on Pickering, and the North West wing houses the Attorney Generals Chambers office. Page 1 of 38

description

A case study report for building science

Transcript of Park Royal Building Science Report

Page 1: Park Royal Building Science Report

PARKROYAL ON PICKERING

Location : 3 Upper Pickering Street, Singapore 058289Year : 2013Architect : WOHADeveloper : Pan Pacific Hotel Groups LimitedProject type : Commercial, Hospitality, Mixed-use, OfficesArea : 29,811 sqm

The hotel has been awarded the BCA Green Mark Platinum award, the highest rating for green buildings in Singapore for its sustainable design. It is also the recipient of the Solar Pioneer Award as one of the first in the hospitality sector to introduce solar-powered sky-gardens with solar cells that power landscape lighting.

PURPOSE OF BUILDINGDesigned as a hotel and office in a garden, the project at Upper Pickering Street is a study of how we can not only conserve our greenery in a built-up high-rise city centre but multiply it in a manner that is architecturally striking, integrated and sustainable.

The building hosts two buildings of different functions. The East wing houses PARKROYAL on Pickering, and the North West wing houses the Attorney Generals Chambers office.

DESIGN CONCEPT, PHILOSOPHY, INTENTIONA contoured podium, referred to as topographical architecture, is mimicked from terraced plantations (Figure 1). It is sculpted to form dramatic outdoor plazas, gardens and terraces which flow seamlessly into the interiors. The crisp and streamlined tower blocks harmonize with surrounding high-rise office buildings. The snaking bands of fluted concrete weave through the length and breadth of the podium without interruption, and without acknowledgment of the boundaries between exterior and interior (Figure 2)

Page 1 of 32

Page 2: Park Royal Building Science Report

Figure 1: Topographical architecture of building.[Taken by: Wong Yoke Lin]

Figure 2: Topographical architecture weaving through the interior from the exterior and vice versa.

Page 2 of 32

Page 3: Park Royal Building Science Report

CERTIFICATIONSBCA Green Mark Platinum Award (Awarded 2012) Solar Pioneer Award (Awarded 2011)

GREEN DESIGN FEATURESExtensive/vertical greenery More than 200 percent of the total land area is constituted by sky gardens and lush landscaping. A massive sky garden with water features is cantilevered at every fourth level between the blocks of guest rooms (Figure 3). Greenery from the adjoining park is drawn up the building in the form of lushly planted openings, crevasses, gullies and waterfalls, which also conceal above ground car park (Figure 4), thus making the hotel appear as one continuous sweep of urban parkland. The interior of the building also features greenery, whereby green walls are placed in areas such as the lobby (Figure 5a) and the separation gap between hotel rooms (Figure 5b).

Figure 3: Sky gardens cantilevering at every fourth level.[Source: http://inhabitat.com/tour-the-parkroyal-hotel-singapores-amazing-sky-gardens-and-greenery-wrapped-towers-photos/parkroyal-singapore-pool/?extend=1]

Page 3 of 32

Page 4: Park Royal Building Science Report

Figure 4: Greenery covering the car park along the outside of the building.[Taken by: Dexter Ng You Sheng]

Figure 5a: Green wall at lobby. Figure 5b: Green wall at separation gaps.[Taken by: Dexter Ng You Sheng]

Page 4 of 32

Page 5: Park Royal Building Science Report

Rainwater harvesting A rainwater harvesting system is implemented in the building. The sky gardens also serve as water catchments and are ‘zero energy’ - irrigated by rainwater harvesting, with a gravity-fed drip system (Figure 7) powered by solar energy from photovoltaic cells on the roof.

Harvested rainwater is used throughout the building’s water features (Figure 6). One of the uses of the harvested rainwater is for the watering of plants within the building. The building’s interior walls are comprised partially of green walls. The plants on the green walls are grown on soil bedding held together by wire mesh (Figure 7).

Small tubes are connected to these wire mesh frames to provide a plant-watering system whereby droplets of water will be released onto the soil from time to time to keep the plants well hydrated in the air-conditioned environment (Figure 7).

Figure 6: Water feature at lobby that use harvested rainwater.[Taken by: Wong Yoke Lin]

Page 5 of 32

Page 6: Park Royal Building Science Report

Figure 7: Plants and soil held by wire mesh, watered by small tube with gravity-fed drip system.[Taken by: Dexter Ng You Sheng]

Extensive use of natural light The E-plan of the building makes the surface area of the building larger, therefore more sunlight is brought into the building due to the different angles that light can penetrate from. Large windows and floor-to-ceiling glass walls are used to maximize the natural light coming into the building. Skylights are also placed at each sky garden to bring sunlight down to the lower levels (Figure 8).

Figure 8: Skylight at cantilevered sky gardens.[Source: http://inhabitat.com/tour-the-parkroyal-hotel-singapores-amazing-sky-gardens-and-greenery-wrapped-towers-photos/parkroyal-singapore-pool/?extend=1]

Page 6 of 32

Page 7: Park Royal Building Science Report

Sun-shading The sky gardens that cantilever out provide partial sun-shading for the building (Figure 3 & 9). Refer passive design elements for further elaboration.

Figure 9: Partial sun-shading.[Source: http://www.lioninthewild.com/2014/01/parkroyal-on-pickering.html]

Natural ventilation The external corridors at every floor are opened up on the side facing the adjacent building. Instead of using a wall, the plants along the sides act as a boundary. This provides plenty of natural ventilation (Figure 10).

Figure 10: Corridor with natural ventilation.

[Source: http://www.lioninthewild.com/2014/01/parkroyal-on-pickering.html]

Page 7 of 32

Page 8: Park Royal Building Science Report

Renewable energy Photovoltaic cells/solar panels are placed on the roof to make full use of the available energy sources. Sunlight is converted into electrical energy and powers reticulation systems and softscape lighting of the whole building.

Cobiaz construction technology This technology lowers concrete usage and carbon emissions, enhancing the building envelope’s thermal performance, lighting power density and overall energy efficiency.

Green Leases for both office tenants and hotel operators A lease between a landlord and tenant of a commercial building which provides obligations on both parties to minimize adverse environmental impact in areas such as energy, water and waste.

Dual refuse chutes separating recyclable from non-recyclable wasteRecycle bins that differentiates the recyclable and non-recyclable rubbish are placed in every room for the guest to dispose of their rubbish with an environmental conscious mind.

Water efficient fittingsEach of the bathroom in the guestrooms have water efficient fittings to save the usage of water. The amount of water disperse can be controlled, thus saving quite a huge sum annually.

Automatic sensors to regulate energy and water usageAutomatic sensors are installed to not only to regulate the amount of water used, but also regulating the energy used in the building.

Use of energy efficient LED and T5 type fluorescent lampsT5 type fluorescent lamps have high efficiency and high output, it helps to save energy and is long life. Energy efficient LED and T5 type fluorescent lamps are used throughout the building to save energy as well as the cost of electricity.

High efficiency air-conditioning systemThe hotel uses high efficiency air-conditioning system in parts of the hotel where it is necessary. The use of this high efficiency air-conditioning system not only saves the energy and electricity, it also saves quite a sum on the bills as air-cons are auto-regulated.

Page 8 of 32

Page 9: Park Royal Building Science Report

LOCATION MAP

Figure 11: Location map

Located in central Singapore, the site is at a junction between the Central Business District and the districts of Chinatown and Clarke Quay, and faces Hong Lim Park (Figure 11).

Page 9 of 32

Page 10: Park Royal Building Science Report

PLANS

Page 10 of 32

Page 11: Park Royal Building Science Report

PLANS

Page 11 of 32

Page 12: Park Royal Building Science Report

ELEVATIONS

SECTIONS

Section A-A

Page 12 of 32

Page 13: Park Royal Building Science Report

Climate Data

Chart 1

Chart 1 shows the climate summary of Singapore during the year 2011. The temperature in Singapore is quite constant as it does not have a rapid change in temperature. The maximum temperature recorded is 34 degree Celsius and the minimum temperature is 22 degree Celsius. However, the average temperature in Singapore is around 27 degree Celsius which is close to the comfort temperature according to Malaysian Standard 1525.

Page 13 of 32

Page 14: Park Royal Building Science Report

Relative Humidity

Chart 2

Chart 2 states average relative humidity of Singapore during the year 2011. According to the statistic, the highest humidity recorded is above 50km/h which stands 75% of the average relative humidity, and it only takes place at the South-West direction. On the other hand, the lowest humidity recorded is below 10km/h which took up 95% of the average relative humidity for all directions. Due to the tropical climate of Singapore, the average relative humidity is in between 45% to 95%, and it did not go below 45% according to the chart above.

Page 14 of 32

Page 15: Park Royal Building Science Report

Wind Studies

Chart 3

The chart 3 above shows the wind frequency of Singapore from the 1st of January to the 31st of December 2011. According to the chart, the highest wind frequency happens in all directions which are less than 38 hours; the lowest wind frequency happens at the North direction which is more than 381 hours. It can be concluded that the wind frequency is the highest at the North-East direction and lowest at the South-West direction. Therefore, the architect of Park Royal hotel designed the building facing North-East fin order to have maximum air ventilation. The architect also designs the walkway to the hotel rooms to be open in order to enjoy natural air ventilation.

Page 15 of 32

Page 16: Park Royal Building Science Report

SUN PATH ANALYSIS

SUN PATH 2nd APRIL 0900

Figure 11

Figure 11 shows the sun path on 2nd of April 0900. During that time, 50% of the highest floor facing North-East is shaded and the floors below the 14th floor facing North-East side are20% shaded. The north facing side of the building is 75% shaded due to the sun path.

Page 16 of 32

Page 17: Park Royal Building Science Report

SUN PATH 2nd APRIL 1200

Figure 12

Figure 12 shows the sun path on 2nd of April 1200. During that time, the north facing side of the building is completely shaded.

Page 17 of 32

Page 18: Park Royal Building Science Report

SUN PATH 2nd APRIL 1600

Figure 13

Figure 13 shows the sun path on 2nd of April 1600. During that time, 100% of all floors facing North-East are completely exposed to sunlight. The hotel has minimal shaded surfaces during that time.

Page 18 of 32

Page 19: Park Royal Building Science Report

SUN PATH 21st JUNE 0900

Figure 14

Figure 14 shows the sun path on 21st of June 0900. During that time, 95% of the building surfaces facing north are completely shaded and 40% of the surfaces facing North-East are shaded.

Page 19 of 32

Page 20: Park Royal Building Science Report

SUN PATH 21st JUNE 1200

Figure 15

Figure 15 shows the sun path on 21st of June 1200. During that time, 97% of all floors facing north are completely shaded and the surfaces facing North-East is 25% shaded.

Page 20 of 32

Page 21: Park Royal Building Science Report

SUN PATH 21st JUNE 1600

Figure 16

Figure 16 shows the sun path on 21st of June 1600. During that time, 100% of the surfaces facing North-East is expose to sunlight, and 98% of the surfaces facing the north side is exposed to sunlight.

Page 21 of 32

Page 22: Park Royal Building Science Report

These sun path diagrams can be concluded that the total surface area shaded in June is higher than in April. Due to the expose of sunlight towards the building on the North-East side, the

architect designed the building such that the open air walkways of the hotel rooms are indented and are blocked by the 3 extruded parts of the building. During 1600, the surface of

the building facing North-East is 100% expose to sunlight. To overcome this problem, extended garden is design at the North-East side of the building to provide extra shades to the building.

Page 22 of 32

Page 23: Park Royal Building Science Report

2 Main Passive Design Features

a) Ventilation

- Naturally Ventilated corridors

Corridors are open and ventilated where the hotel rooms are, to promote natural ventilation. Building is constantly ventilated, does not require much energy on air-conditioning system at the open hallways and corridors.

Figure 17

[Source: http://www.dezeen.com/2013/10/10/parkroyal-on-pickering-by-woha ]

The front facade of the building and the roof gardens are facing north. It is prevailing in the direction of the wind. The hotel is designed in a way such that its orientation is to receive more wind ventilation throughout the building.

Figure 18[Source: http://www.tierradesign.com.sg/project-parkroyal-hotel.php]

Page 23 of 32

Page 24: Park Royal Building Science Report

Diagram 1Plan view of hotel with direction of air ventilation

Page 24 of 32

Page 25: Park Royal Building Science Report

Section A-A

Diagram 2

Showing the wind ventilation in the section of the hotel building.

- Open roof/ Sky garden

The swimming pool at level 5 has an open roof concept. This is to promote natural ventilation along the whole floor. No air-conditioning is used on the whole floor and this saves quite a lot of electricity as a whole annually.

Page 25 of 32

Page 26: Park Royal Building Science Report

Figure 19: The open roof swimming pool/Jacuzzi[Taken by: Dexter Ng You Sheng]

Figure 20: The open roof swimming deck where guest will be able to enjoy the night view of the city, Hong Lim Park.[Taken by: Dexter Ng You Sheng]

Park royal has an open roof sky garden. The function of the sky garden is as a lounge that serves drinks to the guest. It fully depends on natural ventilation of the building. Wind mainly blows from the north, but there are wind blowing from all directions. It keeps the sky garden cool and ventilated. The sky roof garden itself saves a large amount of sum annually.

Page 26 of 32

Page 27: Park Royal Building Science Report

Figure 21

[Source: http://cosmone.com/life/destination-and-travel/parkroyal-pickering#ad-image-15]

b) Sun shading

Park royal on Pickering has also a natural passive design feature that shades the building from the sun. Not only does the building have features that shade some part of itself from the sun, the neighboring context also plays a vital role in sun-shading.

As shade is cast at an urban level, by SOM’s One George Street in the morning and by public housing blocks in the afternoon, sunscreens are unnecessary on the facade, which is plainly rendered in a dark reflective glass intended to fade into the sky.

By itself, Park royal has also features of sun-shading. It has managed to include the use of

Page 27 of 32

Page 28: Park Royal Building Science Report

- Extensive greenery and natural lighting into the overall design of the hotel. The greeneries that are found on the floors of the hotel are for sun shading purposes. It helps to block some of the sunlight that penetrates to the walkway to the hotel rooms. These would make the walkways bright yet sun-shaded.

The greeneries helps to absorb the sunlight and provides more oxygen along the walkway for the guest of the hotel. A cooler walkway is achieved by planting the greeneries along the walkway corridor.

- Park royal uses double glazed low-E glass. Glass used in double glazing window for thermal insulation is known as Low E, or low-emissivity glass. It has a transparent metallic coating that works in two ways to economize heating energy. The dual action coating reflects heat back into the room, whilst allowing heat and light from the sun (known as passive solar heat gain) to pass through.

Page 28 of 32

Sketch 1.1

A sketch of the extensive greeneries used by the hotel for sun-shading purposes

Figure 22

The natural greeneries along sideways also serves to give shade to the corridor.

Sketch 1.2

A sketch of the exterior corridor of the hotel park royal on the ground floor.

Page 29: Park Royal Building Science Report

Diagram 3

The position where the sun shines upon, and the position where low-E glass are being used.

The reason low-E glass are used on both sides of the east and west side is to lower the heat gain in the interior but also keeping the view of the exterior surrounding context. The low-E glass functions to reduce the heat from penetrating in from the exterior.

Section of a low-E glass and how does it work

Figure 23

Page 29 of 32

Page 30: Park Royal Building Science Report

The low-E glass not only reduced the heat captured in the interior of the building, it is also relatively light and transparent, giving a sense of airy-ness to the building.

Summary Chart

Below is a summary of the passive design features used in the building mentioned, Park Royal on Pickering, Singapore. The following design strategy has been used by the building to aid in the passive design aspect (sun-shading and ventilation) of the building.

No. Building Science Aspect Design Strategy1. Sun shading Extensive greenery and natural lighting

Double glazed low-E glass2. Ventilation Open roof/ Sky garden

Naturally Ventilated corridors

Page 30 of 32

Page 31: Park Royal Building Science Report

Diagram 4

The area of passive design features used in the building.

REFERENCES

ArchDaily, 2013. PARKROYAL on Pickering. [online] Available at: http://www.archdaily.com/363164/parkroyal-on-pickering-woha-2/ [Accessed 5 May 2014]

Architect’s Journal, 2013. Green Giant: ParkRoyal by WOHA. [online] Available at: http://www.architectsjournal.co.uk/buildings/green-giant-parkroyal-by-woha/8655579.article [Accessed 5 May 2014]

Better Buildings Partnership, NA. Green Leases. [online] Available at: http://www.betterbuildingspartnership.co.uk/working-groups/green-leases/ [Accessed 5 May 2014]

Building & Construction Authority, 2013. BCA GREEN MARK PLATINUM BUILDINGS (SINGAPORE). [online] Available at: http://www.bca.gov.sg/newsroom/others/pr11092013_IGBCA.pdf [Accessed 5 May 2014]

Inhabitat, 2014. Tour the PARKROYAL Hotel Singapore's Surreal Sky Gardens and Greenery-Wrapped Towers. [online] Available at: http://inhabitat.com/tour-the-parkroyal-hotel-singapores-amazing-sky-gardens-and-greenery-wrapped-towers-photos/parkroyal-singapore-pool/?extend=1[Accessed 5 May 2014].

Lion in the Wild, 2014. ParkRoyal on Pickering. [online] Available at: http://www.lioninthewild.com/2014_01_01_archive.html [Accessed 5 May 2014]

PUB, Singapore’s National Water Agency, 2010. NEWater. [online] Available at: http://www.pub.gov.sg/water/newater/Pages/default.aspx [Accessed 5 May 2014].