PanelView Plus Specifications -...
Transcript of PanelView Plus Specifications -...
Technical Data
PanelView Plus SpecificationsCatalog Numbers 2711P, 2711PC
PanelView Plus Family PanelView Plus HMI terminals are used for applications with a need to monitor, control, and display information graphically, allowing operators to quickly understand the status of their application. All PanelView Plus applications are programmed with FactoryTalk View Studio for Machine Edition (ME) software and have FactoryTalk View ME Station runtime installed on each terminal.
This family provides a broad range of rugged terminals offering these features:• Premier integration with the Integrated Architecture platform• Scalable 4- to 15-inch displays with touch screen, keypad, or both for input• Common development software• Real-time monitoring of a terminal's displays via a web browser
Use this document along with the Visualization Solutions Selection Guide, publication VIEW-SG001, to make decisions on the visualization solutions best suited for your system requirements.
Topic Page
Environmental Specifications 2
Certifications 3
PanelView Plus 6 Terminals 4
PanelView Plus 400 and 600 Terminals 11
PanelView Plus Compact Terminals 15
External Power Supply 18
HMI Software 20
Communication Cables 23
Migration Hardware 27
Additional Resources 28
www.klinkmann.com6 / 2011
2 PanelView Plus Specificationswww.klinkmann.com
6 / 2011
Environmental Specifications
The environmental certifications apply to all PanelView Plus terminals:• PanelView Plus 6 terminals including logic, communication modules,
and 700, 1000, 1250, 1500 display modules• PanelView Plus 400 and 600 terminals• PanelView Plus Compact 400, 600, and 1000 terminals
Table 1 - Environmental Specifications - PanelView Plus Terminals
Attribute 2711P, 2711PC
Temperature, operating 0…55 °C (32…131 °F)
Temperature, storage -25…70 °C (-13…158 °F)
Heat dissipation400, 600700, 1000, 1250, 1500
85 BTU/hr240 BTU /hr
Relative humidity 5...95% noncondensing
Vibration 0.012 in. peak-peak 10…57 Hz2 g at 57…500 Hz
Altitude, operating 2000 m (6561 ft)
Shock, operating 15 g at 11 ms
Shock, nonoperating 30 g at 11 ms
Enclosure ratings NEMA Type 12, 13, 4X (indoor use only), IEC IP54, IP65
Airborne contaminants For PVP/PVP-CE conformal-coated PCBA level products:ANSI/ISA S71.04 - 1985 Severity Level G3EN60654-4: 1998 Class 3
Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010
PanelView Plus Specifications 3www.klinkmann.com6 / 2011
Certifications The certifications apply to all PanelView Plus terminals:• PanelView Plus 6 terminals including logic, communication modules,
and 700, 1000, 1250, 1500 display modules• PanelView Plus 400 and 600 terminals• PanelView Plus Compact 400, 600, and 1000 terminals
Table 2 - Certifications - PanelView Plus Terminals
Certification(1)
(1) When marked. See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details.
2711P, 2711PC
c-UL-us UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E10314.
UL Listed Industrial Control Equipment for use in:• Class I, Div 2, Groups A, B, C, D• Class I, Zone 2, Group IIC (2)
• Class II, Div 2 Groups F, G• Class III Hazardous Locations
(2) Applies only to the 1250 high-bright display module.
CE (EMC) European Union 2004/108/EC EMC Directive, compliant with:• EN 61000-6-2; Industrial Immunity• EN 61000-6-4; Industrial Emissions
CE (LVD) European Union 2006/95/EC Low Voltage Directive, compliant with:• EN 61131-2; Programmable Controllers
C-Tick Australian Radiocommunications Act, compliant with:AS/NZS CISPR 11; Industrial Emissions
Marine(3)
(3) The 700 and 1000 display modules are marked as marine-certified.
Products identified with the suffix M in the catalog number are certified to the requirements of one or more marine societies. For additional marine-certified components, refer to the Product Certification link below this table.
Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010
4 PanelView Plus Specificationswww.klinkmann.com
6 / 2011
PanelView Plus 6 Terminals The PanelView Plus 6 terminals use modular components allowing for flexible configuration, installation, and upgrades. Factory-assembled terminals, with a display module (700, 1000, 1250, 1500) and logic module, are available as a single catalog number or as separate components for field installation. Optional communication modules can be ordered for additional network communication.
The field-replaceable 6.5, 10.4, 12.1, and 15.1-in. flat-panel color displays come with keypad, touch screen, or keypad/touch-screen input. Other display options are available to meet more stringent environmental conditions:
• High-bright display module for outdoor applications• Conformal-coated displays• Marine-certified displays• Displays with built-in antiglare overlays
The high-performance logic module runs the Windows CE 6.0 operating system allowing you to run HMI applications with the ability to also access the desktop. For users with more complex application requirements, the platform and logic module can be ordered with optional, extended features and file viewers.
For a complete listing of catalog number selections, refer to the Visualization Solutions Selection Guide, publication VIEW-SG001.
Table 3 - Logic Module Features
Features Description
High memory capacity 512 MB nonvolatile flash and 512 MB RAM
Power input AC or DC
Network interface For optional DH+, DH-485, or ControlNet communication module
Communication ports Ethernet, RS-232 serial
USB ports • 2 USB host ports for connecting a USB mouse, keyboard, printer, and USB flash drives that are hot swappable
• 1 USB device port for connecting a host personal computer
Secure Digital (SD) card slot Hot-swappable card slot supports 1784-CDx SD cards for transferring files, upgrading firmware, or logging data
Operating system All terminals run the Windows CE 6.0 operating system (OS) providing OS functionality needed for most users needs:• FTP server• VNC client/server• PDF reader• Active X controls• Third-party device support
Additional functionality is available by ordering terminals with optional, extended features:• Internet Explorer web browser• Remote desktop connection• Media player• Microsoft file viewers for PowerPoint, Excel, and Word• WordPad text editor• PDF reader
FactoryTalk View software • FactoryTalk View Machine Edition software, version 6.0 or later, is preloaded and activated on each terminal
• Single license support for FactoryTalk ViewPoint software, version 1.2 or later, gives remote users access to a terminal’s displays via standard web browser
• HMI applications are developed with FactoryTalk View Studio for Machine Edition software, which is purchased separately
Reset and Default Switches Provide easy access to diagnostic and repair operations.
OptionalExtended Features
Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010
PanelView Plus Specifications 5www.klinkmann.com6 / 2011
Technical Specifications - PanelView Plus 6 Terminals
Table 4 - Technical Specifications - PanelView Plus 6 Terminals
Attribute 700 Color(1)
2711P-K7C4Dx, 2711P-T7C4Dx, 2711P-B7C4Dx, 2711P-K7C4Ax, 2711P-T7C4Ax, 2711P-B7C4Ax
1000 Color(1)
2711P-K10C4Dx, 2711P-T10C4Dx, 2711P-B10C4Dx, 2711P-K10C4Ax, 2711P-T10C4Ax, 2711P-B10C4Ax
1250 Color(1)
2711P-K12C4Dx, 2711P-T12C4Dx, 2711P-B12C4Dx, 2711P-K12C4Ax, 2711P-T12C4Ax, 2711P-B12C4Ax
1500 Color(1)
2711P-K15C4Dx, 2711P-T15C4Dx, 2711P-B15C4Dx, 2711P-K15C4Ax, 2711P-T15C4Ax, 2711P-B15C4Ax
Operator input Keypad, Touch, or Key/Touch Keypad, Touch, or Key/Touch Keypad, Touch, or Key/Touch Keypad, Touch, or Key/Touch
Display type Color active-matrix TFT Color active-matrix TFT Color active-matrix TFT Color active-matrix TFT
Display size 6.5 in. 10.4 in. 12.1 in. 15 in.
Display area (WxH) 132 x 99 mm (5.2 x 3.9 in.) 211 x 158 mm (8.3 x 6.2 in.) 246 x 184 mm (9.7 x 7.2 in.) 304 x 228 mm (12.0 x 9.0 in.)
Resolution 640 x 480, 18-bit color graphics 800 x 600, 18-bit color graphics 1024 x 768, 18-bit color graphics
Luminance 300 cd/m2 Nits 300 cd/m2 Nits(2)
Backlight 50,000 h life, min., field replaceableBacklight for 1250 high-bright display module is not replaceable
Touch screen 8-wire analog resistiveActuation: 1 million presses; operating force: 10…110 g
Keypad description Stainless-steel membraneNumeric, navigation, and function keysActuation: 1 million presses; operating force: 340 g
Keypad function keys 22 function keys F1…F10 and K1…K12
32 function keys F1…F16 and K1…K16
40 function keys F1…F20 and K1…K20
40 function keys F1…F20 and K1…K20
Real-time clock Battery-backed clock timestamps critical data, ±2 minutes per monthBattery life: 4 year min. @ 25 °C (77 °F)Field-replaceable: cat. no. 2711P-RY2032
Memory 512 MB nonvolatile flash and 512 MB RAM
External storage Secure Digital (SD) card, cat. no.1784-SDx, supported by hot-swappable SD card slotUSB flash drives supported by high-speed, hot-swappable, 2.0 USB host ports
Operating system Windows CE 6.0 operating system with or without extended features/file viewers
Software FactoryTalk View Machine Edition, version 6.0 or laterFactoryTalk ViewPoint, version 1.2 or later
Communication ports Ethernet (10/100 Mbps, Auto-MDI/MDI-X), RS-232, (2) USB host, (1) USB device Network interface for optional DH+/DH-485, or ControlNet (scheduled or unscheduled) communication module
Input voltage, DC 18…32V DC (24V DC nom)
Power consumption, DC 70 W max (2.9 A at 24V DC)
External power supply Cat. no. 2711P-RSACDIN, Class 2 or Safety Extra-Low Voltage (SELV) power supply for 700 to 1500 DC powered terminals; 85…264V AC, 120VA max
Input voltage, AC 85…264V AC, 47…63 Hz
Power consumption, AC 160VA max
Weight, approx.(3) Keypad: 1.8 kg (4.1 lb)Touch: 1.7 kg (3.7 lb)
Keypad: 2.8 kg (6.2 lb)Touch: 2.5 kg (5.6 lb)
Keypad: 3.4 kg (7.5 lb)Touch: 3.2 kg (7.0 lb)
Keypad: 4.5 kg (9.9 lb)Touch: 4.2 kg (9.2 lb)
Dimensions (HxWxD), approx. (3) Keypad: 193 x 290 x 55 mm7.58 x 11.40 x 2.18 in.
Touch: 179 x 246 x 55 mm7.04 x 9.68 x 2.18 in.
Keypad: 248 x 399 x 55 mm9.77 x 15.72 x 2.18 in.
Touch: 248 x 329 x 55 mm 9.77 x 12.97 x 2.18 in.
Keypad: 282 x 416 x 55 mm 11.12 x 16.36 x 2.18 in.Touch: 282 x 363 x 55 mm 11.12 x 14.30 x 2.18 in.
Keypad: 330 x 469 x 65 mm 12.97 x 18.46 x 2.55 in.Touch: 330 x 416 x 65 mm 12.97 x 16.37 x 2.55 in.
Cutout dimensions (HxWxD) Keypad: 167 x 264 mm6.57 x 10.39 in.
Touch: 154 x 220 mm6.08 x 8.67 in.
Keypad: 224 x 375 mm8.8 x 14.75 in.
Touch: 224 x 305 mm8.8 x 12.0 in.
Keypad: 257 x 390 mm10.11 x 15.35 in.
Touch: 257 x 338 mm10.11 x 13.29 in.
Keypad: 305 x 419 mm12.0 x 16.5 in.
Touch: 305 x 391 mm12.0 x 15.4 in.
(1) Replace x in catalog number with an 8 or 9. For catalog numbers ending in 9, the Windows CE operating system includes extended features and file viewers; catalog numbers ending in 8 do not support these features.
(2) The 1250 high-bright display module, cat. no. 2711P-RDT12H, for outdoor operations, has a luminance of 1000 cd/m2 Nits. The backlight is not replaceable.(3) Weights and dimensions do not include communication module. Add 95 g (0.21 lb) to the weight for a communication module.
Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010
6 PanelView Plus Specificationswww.klinkmann.com
6 / 2011
Terminal Dimensions - PanelView Plus 6 Terminals
The table provides overall dimensions and cutout dimensions for the PanelView Plus 6 terminals. The 1000 keypad and touch terminal is shown for reference. Other models look similar.
b a
1000 Keypad
b a
1000 Touch
Table 5 - PanelView Plus 6 Terminal Dimensions
Terminal Type Width Height Depth a(1) Depth b(2) Cutout Width Cutout Height
700 Keypad or Keypad/Touch 290 mm11.40 in.
193 mm7.58 in.
55 mm2.18 in.
83 mm3.27 in.
264 mm10.39 in.
167 mm6.59 in.
700 Touch 246 mm9.68 in.
179 mm7.04 in.
55 mm2.18 in.
83 mm3.27 in.
220 mm8.67 in.
154 mm6.08 in.
1000 Keypad or Keypad/Touch 399 mm15.72 in.
248 mm9.77 in.
55 mm2.18 in.
83 mm3.27 in.
375 mm14.75 in.
224 mm8.8 in.
1000 Touch 329 mm12.97 in.
248 mm9.77 in.
55 mm2.18 in.
83 mm3.27 in.
305 mm12.00 in.
224 mm8.8 in.
1250 Keypad or Keypad/Touch 416 mm16.36 in.
282 mm11.12 in.
55 mm2.18 in.
83 mm3.27 in.
390 mm15.35 in.
257 mm10.11 in.
1250 Touch 363 mm14.30 in.
282 mm11.12 in.
55 mm2.18 in.
83 mm3.27 in.
338 mm13.29 in.
257 mm10.11 in.
1250 High-bright Touch 363 mm14.30 in.
282 mm11.12 in.
74 mm2.9 in.
101 mm3.99 in.
338 mm13.29 in.
257 mm10.11 in.
1500 Keypad or Keypad/Touch 469 mm18.46 in.
330 mm12.97 in.
65 mm2.55 in.
93 mm3.65 in.
419 mm16.50 in.
305 mm12.00 in.
1500 Touch 416 mm16.37 in.
330 mm12.97 in.
65 mm2.55 in.
93 mm3.65 in.
391 mm15.40 in.
305 mm12.00 in.
(1) Dimension is from display to logic module.(2) Dimension is from display to communication module.
Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010
PanelView Plus Specifications 7www.klinkmann.com6 / 2011
Accessories - PanelView Plus 6 Terminals
Tables 6…18 lists accessories for the PanelView Plus 6 platform.
Table 6 - Display Modules
Cat. No. Input Type Display Marine Certified
ConformalCoated
Built-inAntiglare Overlay
700 Model
2711P-RDK7C Keypad 7-in. color
2711P-RDK7CK Keypad •
2711P-RDT7C Touch
2711P-RDT7CK Touch •
2711P-RDT7CM Touch •
2711P-RDB7C Keypad/Touch
2711P-RDB7CK Keypad/Touch •
2711P-RDB7CM Keypad/Touch •
1000 Model
2711P-RDK10C Keypad 10-4 in. color
2711P-RDT10C Touch
2711P-RDT10CM Touch •
2711P-RDB10C Keypad/Touch
2711P-RDB10CM Keypad/Touch •
1250 Model
2711P-RDK12C Keypad 12.1-in. color
2711P-RDK12CK Keypad •
2711P-RDT12C Touch
2711P-RDT12CK Touch •
2711P-RDT12AG Touch •
2711P-RDT12H(1)
(1) This catalog number is a high-bright display module, indicated by the H at end of cat. no., that is designed for outdoor applications. The high-bright display module can only be used with DC-powered logic modules.
Touch
2711P-RDB12C Keypad/Touch
2711P-RDB12CK Keypad/Touch •
1500 Model
2711P-RDK15C Keypad 15-in. color
2711P-RDT15C Touch
2711P-RDT15AG Touch •
2711P-RDB15C Keypad/Touch
Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010
8 PanelView Plus Specificationswww.klinkmann.com
6 / 2011
Table 7 - Logic Modules
Cat. No. Power Input
Nonvolatile Flash/ RAM Memory Communication Conformal
Coated Included Software
Without Extended Features
2711P-RP8A AC 512 MB/512 MB • Ethernet• RS-232• Network interface for
communication module
• Windows CE 6.0 operating system without extended features/file viewers
• FactoryTalk View Machine Edition runtime, version 6.0 or later
• FactoryTalk ViewPoint, version 1.2 or later
2711P-RP8D DC 512 MB/512 MB
2711P-RP8DK DC 512 MB/512 MB •
With Extended Features
2711P-RP9A AC 512 MB/512 MB • Ethernet• RS-232• Network interface
communication module
• Windows CE 6.0 operating system with extended features/file viewers
• FactoryTalk View Machine Edition runtime, version 6.0 or later
• FactoryTalk ViewPoint, version 1.2 or later
2711P-RP9D DC 512 MB/512 MB
2711P-RP9DK DC 512 MB/512 MB •
Table 8 - Communication Modules
Cat. No.Communication Conformal
CoatedMarine CertifiedDH+ DH-485 ControlNet (1)
(1) Scheduled and unscheduled communication.
2711P-RN6 • •
2711P-RN6K • • •
2711P-RN15S • •
2711P-RN15SK • •
Table 9 - Secure Digital (SD) Cards
Cat. No. Description
1784-SD1 1 GB Secure Digital (SD) card
1784-SD2 2 GB Secure Digital (SD) card
2711C-RCSD USB to SD adapter for secure Digital card (SD)
Table 10 - Function Key Legend Inserts
Cat. No.PanelView Plus 6 Terminal Model(1)
(1) Applies to keypad and keypad/touch-screen terminals.
Includes
2711P-RFK7 700 keypad
Blank legend inserts and software
2711P-RFK10 1000 keypad
2711P-RFK12 1250 keypad
22711P-RFK15 1500 keypad
Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010
PanelView Plus Specifications 9www.klinkmann.com6 / 2011
Table 11 - Antiglare Overlays
Cat. No.(1)
(1) Three overlays are shipped with each catalog number.
PanelView Plus 6 Terminal Model
Operator Input
Keypad Touch Key/Touch
2711P-RGK7700
• •
2711P-RGT7 •
2711P-RGK101000
• •
2711P-RGT10 •
2711P-RGK121250
• •
2711P-RGT12 •
2711P-RGK151500
• •
2711P-RGT15 •
Table 12 - Solar Visor
Cat. No. Description
2711P-RVT12 Solar visor for 1250 high-bright display module, cat. no. 2711P-RDT12H
Table 13 - Mounting Hardware
Cat. No. Description Quantity
2711P-RTMC Mounting clips 8
Table 14 - Battery Replacement
Cat. No. Description Quantity
2711P-RY2032 Replacement battery 1
Table 15 - Power Supply and Power Terminal Blocks
Cat. No. Description Quantity
2711P-RSACDIN DIN-rail power supply, AC-to-DC, 85…265V AC, 47…63 Hz 1
2711P-RTBAC3 AC power terminal block 10
2711P-RTBDC2 2-pin DC power terminal block 10
Table 16 - Programming Cable
Cat. No. Description Length
2711C-CBL-UU02 USB host to USB device programming cable 2 m (6.5 ft)
Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010
10 PanelView Plus Specificationswww.klinkmann.com
6 / 2011
Table 17 - Backlight Replacements
Cat. No. PanelView Plus 6 Display Module Size Series Number of
Backlights
2711P-RL7C 700 A and B 1
2711P-RL7C2 C and D 1
2711P-RL10C 1000 A 1
2711P-RL10C2 B and C 1
2711P-RL12C 1250 A and B 2
2711P-RL12C2 C 1
2711P-RL15C 1500 B 2
Table 18 - Bezel Replacements
Cat. No. PanelView Plus 6 Terminal Model
Operator Input
Keypad Touch Key/Touch
2711P-RBK7
700
•
2711P-RBT7 •
2711P-RBB7 •
2711P-RBK10
1000
•
2711P-RBT10 •
2711P-RBB10 •
2711P-RBK12
1250
•
2711P-RBT12 •
2711P-RBT12H(1)
(1) Applies to the cat. no. 2711P-RDT12H 1250 high-bright display module.
•
2711P-RBB12 •
2711P-RBK15
1500
•
2711P-RBT15 •
2711P-RBB15 •
Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010
PanelView Plus Specifications 11www.klinkmann.com6 / 2011
PanelView Plus 400 and 600 Terminals
The PanelView Plus 400 and 600 terminals combine a 3.5 or 5.5-in. display, logic module, memory, and power (AC or DC) in the base unit. The terminals offer a range of display and input options:
• PanelView Plus 400 grayscale graphic displays with keypad input• PanelView Plus 400 color graphic displays with keypad or combination
keypad/touch-screen input• PanelView Plus 600 color or grayscale graphic displays with keypad, touch
screen, or combination keypad/touch-screen input
Two base units are available.
Other features include the following:• Unique mounting mechanism requiring a single die-cut and no special
tools for installation• Replaceable bezel ID labels for terminal or system identification• Function key legend kit and software for customizing the function key
legends of PanelView Plus 600 keypad terminals• Same panel cutouts as the PanelView Standard 550 terminals
Each terminal is preloaded with FactoryTalk View Machine Edition that does not require activation. Applications are created using FactoryTalk View Studio for Machine Edition software.
For a complete listing of catalog number selections, refer to the Visualization Solutions Selection Guide, publication VIEW-SG001.
Table 19 - Base-configured Terminals
Base Unit Contains
RS-232 unit This base unit contains the following:• RS-232 communication port• USB port connects to mouse, keyboard, printer, bar code
scanner and other devices.• CompactFlash slot for file transfers and data loggingFor applications with limited budgets that require only PLC communication, the RS-232 port of this unit supports DF1, DH-485, and other multivendor PLC protocols.
Ethernet and RS-232 unit This base unit contains the following:• Ethernet port• RS-232 communication port• USB port connects to mouse, keyboard, printer, bar code
scanner and other devices.• CompactFlash slot for file transfers and data logging.• Network interface for optional communication modules
including DH-485, DH+, ControlNet, and isolated RS-232For distributed and complex applications requiring PLC communication, this unit can provide simultaneous communication with multiple networks.
Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010
12 PanelView Plus Specificationswww.klinkmann.com
6 / 2011
Technical Specifications - PanelView Plus 400 and 600 Terminals
Table 20 - Technical Specifications - PanelView Plus 400 and 600 Terminals
Attribute 400 Grayscale
2711P-K4M400 Color
2711P-K4C, -B4C600 Grayscale
2711P-K6M, -T6M, -B6M600 Color
2711P-K6C, -T6C, -B6C
Operator input Keypad Keypad or Keypad/Touch Keypad, Touch, or Key/Touch Keypad, Touch, or Key/Touch
Display type Grayscale passive-matrix FSTN
Color active-matrix TFT Grayscale passive-matrix FSTN
Color active-matrix TFT
Display size 3.8 in. 3.5 in. 5.5 in.
Display area (WxH) 78 x 59 mm (3.07 x 2.32 in.) 71 x 53 mm (2.8 x 2.1 in.) 111 x 84 mm (4.37 x 3.30 in.)
Resolution 320 x 240, 32-level gray 320 x 24018-bit color graphics
320 x 240, 32-level gray 320 x 24018-bit color graphics
Luminance 120 cd/m2 Nits 200 cd/m2 Nits 300 cd/m2 Nits 300 cd/m2 Nits
Backlight LED CCFL 50,000 h life, min.; not replaceable
Touch screen — Analog resistiveActuation: 1 million pressesOperating force: 10…110 g
Analog resistiveActuation: 1 million pressesOperating force: 10…110 g
Keypad description Poly-domed membraneNumeric, navigation, and function keysActuation: 1 million presses; operating force: 340 g
Stainless-steel membraneNumeric, navigation, and function keysActuation: 1 million presses; operating force: 340 g
Keypad function keys 8 function keys (F1…F8) 10 function keys (F1…F10)
Real-time clock Battery-backed clock timestamps critical data, ±2 minutes per month
Battery Not replaceable - Battery life: 5 year min. @ 25 °C (77 °F)
Memory 64 MB nonvolatile flash/64 MB RAM for bitmaps or recording data (not expandable); 20 MB for application storage
External storage 256 MB (cat. no. 2711P-RC3) or 512 MB (cat. no. 2711P-RC4) CompactFlash card
Software FactoryTalk View Studio for Machine Edition or Enterprise Series
Communication ports RS-232 and 1 USB or Ethernet, RS-232, and 1 USB plus optional DH-485, DH+, ControlNet(1), or Isolated RS-232 communication module
Input voltage, DC 18…30V DC (24V DC nom)
Power consumption, DC 25 W max (1.0 A at 24V DC)
External power supply Cat. no. 2711P-RSACDIN, Class 2 or Safety Extra-Low Voltage (SELV) isolated power supply for non-isolated 400 and 600 DC powered terminals; 85…264V AC, 120VA max
Input voltage, AC 85…264V AC, 47…63 Hz
Power consumption, AC 60VA max
Weight, approx. Keypad: 562 g (1.24 lb)Touch: —
Keypad: 562 g (1.24 lb)Touch: —
Keypad: 930 g (2.05 lb)Touch: 789 g (1.74 lb)
Dimensions (HxWxD), approx. Keypad: 152 x 185 x 90 mm6.0 x 7.28 x 3.54 in.
Touch: —
Keypad: 152 x 185 x 90 mm6.0 x 7.28 x 3.54 in.
Touch: 152 x 185 x 90 mm6.0 x 7.28 x 3.54 in.
Keypad: 167 x 266 x 98 mm6.58 x 10.47 x 3.86 in.
Touch: 152 x 185 x 98 mm6.0 x 7.28 x 3.86 in.
Cutout dimensions (HxWxD) Keypad: 123 x 156 mm4.86 x 6.15 in.
Touch: —
Keypad: 123 x 156 mm4.86 x 6.15 in.
Touch: 123 x 156 mm4.86 x 6.15 in.
Keypad: 142 x 241 mm5.61 x 9.50 in.
Touch: 123 x 156 mm4.86 x 6.15 in.
(1) ControlNet network requires FactoryTalk View Machine Edition software, version 4.0 or later.
Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010
PanelView Plus Specifications 13www.klinkmann.com6 / 2011
Terminal Dimensions - PanelView Plus 400 and 600 Terminals
The table provides overall dimensions and cutout dimensions for the PanelView 400 and 600 terminals. The 600 touch, and keypad and touch terminal are shown for reference.
+
ba
600 Keypad Shown
ab
600 Touch Shown
Table 21 - PanelView Plus 400 and 600 Terminal Dimensions
Terminal Type Width Height Depth a Depth b Cutout Width Cutout Height
400 Keypad 185 mm7.28 in.
152 mm6.00 in.
60 mm2.35 in.
90 mm3.54 in.
156 mm6.15 in.
123 mm4.86 in.
600 Keypad and Touch 266 mm10.57 in.
167 mm6.58 in.
68 mm2.68 in.
98 mm3.86 in.
241 mm9.50 in.
142 mm5.61 in.
600 Touch 185 mm7.28 in.
152 mm6.00 in.
68 mm2.68 in.
98 mm3.86 in.
156 mm6.15 in.
123 mm4.86 in.
Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010
14 PanelView Plus Specificationswww.klinkmann.com
6 / 2011
Accessories - PanelView Plus 400 and 600 Terminals
Tables 22…27 lists accessories for the PanelView Plus 400 and 600 terminals.
Table 22 - Communication Modules
Cat. No.Communication
DH+ DH-485 ControlNet(1)
(1) Scheduled and unscheduled communication.
RS-232 Isolated
2711P-RN3 •
2711P-RN8 •
2711P-RN15C •
2711P-RN22C •
Table 23 - Antiglare Overlays
Cat. No.(1)
(1) Three overlays are shipped with each catalog number.
Terminal ModelInput Type
Keypad Touch Key/Touch
2711P-RGK4 400 Grayscale •
2711P-RGB4 400 Color • •
2711P-RGK6600 Grayscale or Color
• •
2711P-RGT6 •
Table 24 - CompactFlash Cards
Cat. No. Description
2711P-RC3 256 MB blank CompactFlash card
2711P-RC4 512 MB blank CompactFlash card
2711P-RCH CompactFlash to PCMCIA adapter
Table 25 - Power Terminal Blocks
Cat. No. Description Quantity
2711P-RVAC AC power terminal block 10
2711-TBDC DC power terminal block 10
Table 26 - Mounting Hardware
Cat. No. Description Quantity
2711P-RTFC Mounting levers 8
Table 27 - Function Key Legend Inserts
Cat. No. Terminal Model Includes
2711P-RFK6 600 keypad and keypad/touch Blank legend inserts and software
Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010
PanelView Plus Specifications 15www.klinkmann.com6 / 2011
PanelView Plus Compact Terminals
The PanelView Plus Compact 400, 600, and 1000 terminals provide a solution for midsize applications requiring fewer displays and alarms in a FactoryTalk View ME application. These terminals are a subset of the PanelView Plus family with selective hardware and software functionality. They are the preferred HMI solution for many of the CompactLogix controllers.
These are the major features of the PanelView Plus Compact terminals:• Preferred HMI for CompactLogix controllers• RS-232 serial port, Ethernet port, USB port (two on 1000 model), DC
power input, and CompactFlash Type 1 slot• Serial and Ethernet communication only• Connection to a single controller by using either RSLinx Enterprise
software, version 5.20 or later, or KEPServer software• 25 displays and 200 alarm messages supported in the FactoryTalk View
Compact Machine Edition application and runtime software• Fixed hardware configurations without the addition or replacement of
modular components
For a complete listing of catalog number selections, refer to the Visualization Solutions Selection Guide, publication VIEW-SG001.
Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010
16 PanelView Plus Specificationswww.klinkmann.com
6 / 2011
Technical Specifications - PanelView Plus Compact Terminals
Table 28 - Technical Specifications - PanelView Plus Compact Terminals
Attribute 400 Grayscale
2711PC-K4M20D400 Color
2711PC-B4C20D600 Grayscale
2711PC-T6M20D600 Color
2711PC-T6C20D1000 Color
2711PC-T10C4D1
Operator input Keypad Keypad/Touch Touch Touch Touch
Display type Passive-matrix FSTN Active-matrix TFT Passive-matrix FSTN Active-matrix TFT Active-matrix TFT
Display size 3.8 in. 3.5 in. 5.5 in. 10.4 in.
Display area (WxH) 78 x 59 mm (3.07 x 2.32 in.) 71 x 53 mm (2.8 x 2.1 in.) 111 x 84 mm (4.37 x 3.30 in.) 211 x 158 mm (8.3 x 6.2 in.)
Resolution 320 x 240, 32-level gray 320 x 240, 18-bit color 320 x 240, 32-level gray 320 x 240, 18-bit color 640 x 480, 18-bit color
Luminance 120 cd/m2 Nits 200 cd/m2 Nits 300 cd/m2 Nits 300 cd/m2 Nits
Backlight LED CCFL 50,000 h life, min.Not replaceable
CCFL 50,000 h life, min., field replaceable
Touch screen — Analog resistive; actuation 1 million presses; operating force 10…110 g
Keypad description Poly-domed membraneNumeric, navigation, and function keysActuation: 1 million presses; operating force: 340 g
Stainless-steel membraneNumeric, navigation, and function keysActuation: 1 million presses; operating force: 340 g
Keypad function keys 8 function keys (F1…F8) — — —
Real-time clock Battery-backed clock timestamps critical data, ±2 minutes per month
Battery 5 year min. @ 25 °C (77 °F);Not replaceable
4 year min. @ 25 °C (77 °F)Replacement: 2711P-RY2032
Memory 64 MB nonvolatile flash/64 MB RAM, non-expandable20 MB for application storage
64 MB nonvolatile flash/64 MB RAM, non-expandable;25 MB for application storage
External storage 256 MB (cat. no. 2711P-RC3) or 512 MB (cat. no. 2711P-RC4) CompactFlash card
Software FactoryTalk View Studio for Machine Edition, version 5.1
Communication ports RS-232, Ethernet, 1 USB; no communication interface RS-232, Ethernet, 2 USB; no communication interface
Input voltage, DC 18…30V DC (24V DC nom) 18…32V DC (24V DC nom)
Power consumption, DC 25 W max (1.0 A at 24V DC) 70 W max (2.9 A at 24V DC)
External power supply Cat. no. 2711P-RSACDIN, Class 2 or Safety Extra-Low Voltage (SELV) isolated power supply for DC powered terminals; 85…264V AC, 120VA max
Weight, approx. 562 g (1.24 lb) 562 g (1.24 lb) 789 g (1.74 lb) 2.6 kg (5.7 lb)
Dimensions (HxWxD), approx.
152 x 185 x 90 mm6.0 x 7.28 x 3.54 in.
152 x 185 x 90 mm6.0 x 7.28 x 3.54 in.
152 x 185 x 98 mm6.0 x 7.28 x 3.86 in.
248 x 329 x 55 mm9.77 x 12.97 x 2.18 in.
Cutout dimensions (HxWxD)
123 x 156 mm4.86 x 6.15 in.
123 x 156 mm4.86 x 6.15 in.
123 x 156 mm4.86 x 6.15 in.
224 x 305 mm8.8 x 12.0 in.
Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010
PanelView Plus Specifications 17www.klinkmann.com6 / 2011
Accessories - PanelView Plus Compact Terminals
Tables 29…34 lists accessories for the PanelView Plus Compact terminals.
Table 29 - Antiglare Overlays
Cat. No.(1)
(1) Three overlays are shipped with each catalog number.
Terminal ModelOperator Input
Keypad Touch Key/Touch
2711P-RGK4 400 grayscale •
2711P-RGB4 400 color • •
2711P-RGT6 600 color grayscale •
2711P-RGT10 1000 color •
Table 30 - CompactFlash Cards
Cat. No. Description
2711P-RC3 256 MB blank CompactFlash card
2711P-RC4 512 MB blank CompactFlash card
2711P-RCH CompactFlash to PCMCIA Adapter
Table 31 - Backlight Replacement
Cat. No. Description
2711P-RL10C2 Color backlight replacement for the 1000 series B and C displays
Table 32 - Bezel Replacements
Cat. No. Description
2711P-RBT10 Replacement bezel for the 1000 touch terminal
Table 33 - Mounting Hardware
Cat. No. Terminal Model Description Quantity
2711P-RTFC 400 and 600 Mounting levers 8
2711P-RTMC 1000 Mounting clips 8
Table 34 - Power Terminal Blocks
Cat. No. Terminal Model Description Quantity
2711-TBDC 400 and 600 DC power terminal block 10
2711P-RTBDC2 700 to 1500 series E or later
2-pin DC power terminal block 10
Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010
18 PanelView Plus Specificationswww.klinkmann.com
6 / 2011
External Power Supply This SELV or PELV, 24V DC power supply can be used to power any of the
PanelView Plus terminals with a DC power input. This power supply provides
protection so that under normal and single fault conditions, the voltage
between conductors and earth ground does not exceed a safe value.
Table 35 - Environmental Specifications - 2711P-RSACDIN Power Supply
Attribute 2711P-RSACDIN
Temperature, operatingIEC 60068-2-1 (Test Ad, Operating Cold)IEC 60068-2-2 (Test Bd, Operating Dry Heat)IEC 60068-2-14 (Test Nb, Operating Thermal Shock)
0…55 °C (32…131 °F)
Temperature, storageIEC 60068-2-1 (Test Ab, Unpackaged, Nonoperating Cold)IEC 60068-2-2 (Test Bb, Unpackaged, Nonoperating Dry Heat)IEC 60068-2-14 (Test Nb, Unpackaged, Nonoperating Thermal Shock)
-40…85 °C (-40…185 °F)
Relative humidityIEC 60068-2-30 (Test Db, Unpackaged, Nonoperating Damp Heat)
5...95% noncondensing
VibrationIEC 60068-2-6 (Test Fc, Operating)
5 g at 10…500 Hz
Shock, operatingIEC 60068-2-27 (Test Ea, Unpackaged Shock)
15 g
Shock, nonoperatingIEC 60068-2-27 (Test Ea, Unpackaged Shock)
30 g
ESD immunityIEC 61000-4-2
4 kV contact discharges8 kV air discharges
Radiated RF immunityIEC 61000-4-3
10V/m with 1 kHz sine-wave 80% AM from 30…1000 MHz
EFT/B immunityIEC 61000-4-4
±2 kV at 5 kHz on power ports
Surge transient immunityIEC 61000-4-5
±1 kV line-line (DM) and ±2 kV line-earth (CM) on AC power ports
Conducted RF immunityIEC 61000-4-6
10V rms with 1kHz sine wave 80% AM from 150 kHz…80 MHz
Enclosure type rating None (open-style)
Power conductorsWire Size
Category
12 gauge (4 mm2 ) max solid or stranded copper wire rated at 75 °C (167 °F) or greater1.2 mm ((3/64 in.) insulation max1 (1)
(1) Use this conductor capacity information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
Table 36 - Certifications - 2711P-RSACDIN Power Supply
Certification(1)
(1) When marked. See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details.
2711P-RSACDIN
c-UL-us UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E10314.UL Listed for Class, Division 2 Groups A, B, C, and D for US and Canada.
CE European Union 89/336/EEC EMC Directive, compliant with:• EN 61000-6-2; Industrial Immunity• EN 61326, Meas./Control/Lab., Industrial Requirements• EN 61000-6-4; Industrial EmissionsEuropean Union 73235/EEC Low Voltage Directive, compliant with:• EN 61131-2; Programmable Controllers
C-Tick Australian Radiocommunications Act, compliant with:AS/NZS 2064, Industrial Emissions
Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010
PanelView Plus Specifications 19www.klinkmann.com6 / 2011
Table 37 - Technical Specifications - 2711P-RSACDIN Power Supply
Attribute 2711P-RSACDIN
Input Specifications
Supply voltage, nom 120V AC, 47…63 Hz, 1.7 A max230V AC, 47…63 Hz, 1.1 A max
Voltage range 85…265V AC
Inrush current 40 A typical, 1 AC cycle at Vin 265V AC, 55 °C (131 °F)
Interruption Output voltage will stay within specification when input drops out for 1/2 cycle at 47 Hz, 85V AC with max load
Output Specifications
Output voltage, nom +24V DC SELV
Voltage range 20.4…27.6V DC, includes noise and 5% AC ripple
Inrush current 40 A typical, 1 AC cycle at Vin 265V AC, 55 °C (131 °F)
Minimum load 50 mA
Overvoltage protection Output internally limited to 35V DC. Cycle power to re-energize.
Overcurrent protection Current limit 3.2 A min (107% min)
Leakage current 0.5 mA rms max at rated input and output
Isolation voltage 2830V DC for 1 second
Table 38 - Dimensions - 2711P-RSACDIN Power Supply
Attribute 2711P-RSACDIN
Mounting Horizontal on a DIN railWall or panel mount with cat. no. 1794-NM1 panel mounting kit
Terminal screw torque 0.5…0.6 N•m (5…7 lb•in)
Dimensions (HxWxD), approx. 87 x 68 x 69 mm (3.4 x 2.7 x 2.7 in.)
Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010
20 PanelView Plus Specificationswww.klinkmann.com
6 / 2011
HMI Software All PanelView Plus terminals are configured with FactoryTalk View Studio software and have an integrated runtime system called FactoryTalk View Machine Edition Station.
Machine Edition Station runs projects developed with FactoryTalk View Studio. Two versions of FactoryTalk View Studio support application development for PanelView Plus terminals.
You can import PanelView Standard/PanelBuilder32 and PanelView e applications into FactoryTalk View Studio as Machine Edition applications using the Machine Edition Import Wizard. The Import Wizard steps you through a few options such as scaling to a new screen resolution size, and then converts objects, text, tags, and communication configurations to ones that are available in Machine Edition.
FactoryTalk ViewPoint software, an add-on to FactoryTalk View Studio software, allows plant managers, production supervisors, system integrators, and other key stakeholders to view real-time plant floor operations remotely from a web browser. FactoryTalk ViewPoint enabled displays are fully scalable and animated in the browser. The remote user can also view displays that are not the active display of the terminal.
Each PanelView Plus 6 terminal contains one license supporting a single client connection to the terminal. No additional software is required.
For a complete list of available HMI software, visit http://www.rockwellautomation.com/rockwellsoftware.
Table 39 - HMI Software for PanelView Plus Terminals
Cat. No, Description
9701-VWSTMENE FactoryTalk View Studio for Machine Edition - Configuration software for developing and testing machine level human machine interface (HMI) applications.
9701-VWSTENE FactoryTalk View Studio - Configuration software for developing and testing machine level and supervisory level human machine interface (HMI) applications.
Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010
PanelView Plus Specifications 21www.klinkmann.com6 / 2011
Software ComparisonTECHNOLOGY: Customer Requirements FactoryTalk View Site Edition FactoryTalk View Machine Edition RSView32
Operating systems (32-bit) • Windows XP• Windows Server 2003• Windows Vista Business• Windows Server 2008
• Windows XP• Windows 7 Professional• Windows CE• Windows Vista Home Basic/Vista Business• Windows Server 2003/2008
• Windows XP/2000/NT/9x/• Windows Server 2003
Embedded platforms ✔
Windows domain security ✔ ✔ ✔
OPC/ActiveX ✔ ✔ ✔
FactoryTalk enabled ✔ ✔ ✔
Server-side VBA ✔
Client-side VBA ✔
ARCHITECTURE: Customer Requirements FactoryTalk View Site Edition FactoryTalk View Machine Edition RSView32
Primary application Supervisory level: single-station or multiple-server, multiple-client
Machine level: single-station Supervisory level; single station or single server, multiple client
Tag-based HMI ✔ ✔ • Windows XP/2000/NT/9x/• Windows Server 2003
Direct referencing ✔ ✔
Network (Distributed) Local
Max number of servers/clients 10/50 1/20
FactoryTalk ViewPoint ✔ ✔ ✔ (1) ✔
RSView32 web server ✔
Thin clients (terminal services) ✔ ✔
Multi-user development ✔
Remote configuration at runtime ✔
Redundancy - data server ✔
Redundancy - HMI server ✔ Active display
(1) Supported only on PanelView Plus terminals.
FEATURES: Customer Requirements FactoryTalk View Site Edition FactoryTalk View Machine Edition RSView32
Animation - visibility, color, fill, horizontal and vertical position, width, height, rotation, horizontal and vertical slider, and more
And touch And touch And touch
Alarms • Tag-based and device-based • Digital and analog• Definable alarm severities• Alarm log
• State-based (from controller)• Alarm log
• Tag-based• Digital and analog• Definable alarm severities• Alarm log
Data logging • 20 data log models per project• Each with up to 10,000 tags• Log to ODBC or proprietary database
• 1 data log model per project• With up to 100 tags• 300K records max• Export to dbf
• 20 plus data log models per project• Each with up to 10,000 tags• Log to ODBC or proprietary database
Trending TrendX 4.0 TrendX 4.0 subset TrendX 3.1 and native
Security • Security assigned to tags, graphic displays, macros, commands, OLE objects
• Local or Windows security
• Display-based• Local or Windows security
• Security assigned to tags, graphic displays, macros, commands, OLE objects
• Local or Windows security
Other features • Test run macros• Derived tags • Event detector
• Test run macros• Derived tags
• Test run macros• Derived tags • Event detector
Pricing model • Display-based pricing • Multiple levels
• Included with PanelView Plus or display-based pricing
• Multiple levels for FactoryTalk View ME Station
• Tag-based pricing• Multiple levels
Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010
22 PanelView Plus Specificationswww.klinkmann.com
6 / 2011
Software Selection
FactoryTalk View Studio for Machine Edition software is configuration
software for developing and testing machine level HMI applications. It
includes RSLinx Enterprise and KEPServer Enterprise.
FactoryTalk View Machine Edition Station is the runtime environment used to run FactoryTalk View ME projects created with FactoryTalk View Studio software on any computer with the Windows 7 Professional, XP/Vista Home Basic/Vista Business/Windows Server 2003/2008 operating system including the industrial computers. FactoryTalk View ME Station is included with all PanelView Plus terminals.
FactoryTalk ViewPoint software is an add-on to FactoryTalk View Studio
software, allowing casual users to view real-time plant floor operations
remotely from a web browser. FactoryTalk ViewPoint server and a single client
access license is included with the purchase of a PanelView Plus terminal. No
other catalog numbers are required to use FactoryTalk ViewPoint software
with PanelView Plus terminals.
Table 40 - FactoryTalk View Machine Edition (ME) Software
Cat. No.(1)
(1) Order localized versions of the software by replacing EN in the catalog number with DE for German, FR for French, JP for Japanese, or ZH for Chinese.
Description
9701-VWSTMENE FactoryTalk View Studio Machine Edition
Table 41 - FactoryTalk View Machine Edition (ME) Station Runtime
Cat. No.(1)
(1) Order localized versions of the software by replacing EN in the catalog number with DE for German, FR for French, JP for Japanese, or ZH for Chinese.
Description
9701-VWMR015AENE FactoryTalk View ME Station runtime 15 displays
9701-VWMR030AENE FactoryTalk View ME Station runtime 30 displays
9701-VWMR075AENE FactoryTalk View ME Station runtime 75 displays
9701-VWMR250AENE FactoryTalk View ME Station runtime 250 displays RS-232 operating cable, 9-pin D Shell to 8-pin Mini DIN
Table 42 - FactoryTalk ViewPoint Software
Cat. No.(1)
(1) Order any of these catalog numbers to use FactoryTalk ViewPoint software with FactoryTalk View SE network or local applications.
Description
9552-VWP01RENE FactoryTalk ViewPoint 1 client system (read only)
9552-VWP03RENE FactoryTalk ViewPoint 3 client system (read only)
9552-VWP05RENE FactoryTalk ViewPoint 5 client system (read only)
9552-VWP10RENE FactoryTalk ViewPoint 10 client system (read only)
9552-VWP25RENE FactoryTalk ViewPoint 25 client system (read only)
9552-VWP50RENE FactoryTalk ViewPoint 50 client system (read only)
Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010
PanelView Plus Specifications 23www.klinkmann.com6 / 2011
Communication Cables The table provides a general list of cables used by the PanelView Plus terminals. All PanelView Plus terminals use a standard Ethernet cable for application transfers between a computer and the terminal.
PanelView Plus Runtime CablesTables 44…47 list required runtime cables for PanelView Plus 400/600 and PanelView Plus 6 (700, 1000, 1250, 1500) terminals.
Table 43 - Cables
Cat. No. Description Length
2711C-CBL-UU02(1)
(1) This cable is used only by PanelView Plus 6 terminals.
USB host to USB device programming cable 2 m (6.5 ft)
2711-NC13 RS-232 operating/program cable, 9-pin D-shell to 9-pin D-shell 5 m (16.4 ft)
2711-NC14 RS-232 operating/program cable, 9-pin D-shell to 9-pin D-shell 10 m (32.7 ft)
2711-NC17 Remote RS-232 cable assembly, 9-pin D-shell to 9-pin D-shell 3 m (10 ft)
2711-NC21 RS-232 operating cable, 9-pin D-shell to 8-pin mini DIN 5 m (16.4 ft)
2711-NC22 RS-232 operating cable, 9-pin D-shell to 8-pin mini DIN 15 m (49 ft)
1761-CBL-AS03DH-485 network cable, 6-pin Phoenix to RJ45
3 m (10 ft)
1761-CBL-AS09 9 m (30 ft)
2711P-CBL-EX04 Ethernet CAT5 crossover cable 4.3 m (14 ft)
Table 44 - Runtime Communication Cables: PanelView Plus Terminals to SLC Controllers
Protocol PanelView Plus Comm Port400, 600, 700, 1000, 1250, 1500
SLC 500, 5/01, 5/02CH1 RJ45 (DH-485)
SLC 5/03, 5/04, 5/05CH0 (9-pin RS-232)
(DF1 or DH-485)
SLC 5/03CH1 (RJ45)
(DH-485)SLC 5/04
CH1 (DH+)SLC 5/05
CH1 (ENET)
DF1 RS-232 (DF1) port (9-pin)PanelView Plus 400 to 15002711P-RN22C (for 400 and 600 only)
— 2711-NC13 (5 m/16 ft)2711-NC14 (10 m/32 ft)
— — —
DH-485
RS-232 (DH-485) port (9-pin)PanelView Plus 400 to 15002711P-RN22C (for 400 and 600 only)
Use AIC+ module(1761-NET-AIC)
to connect to port 1 or 2
2711-NC13 (5 m/16 ft)2711-NC14 (10 m/32 ft)
Use AIC+ Module(1761-NET-AIC)
to connect to port 1 or 2— —
DH-485 portPanelView Plus 400 and 600Requires 2711P-RN3(1)
1747-C10 (2 m/6 ft) 1747-C11 (0.3 m/1 ft)1747-C20 (6 m/20 ft)
Use AIC+ module(1761-NET-AIC)
to connect to port 3
1747-C10 (2 m/6 ft) 1747-C11 (0.3 m/1 ft)1747-C20 (6 m/20 ft)
— —
DH-485 portPanelView Plus 700 to 1500Requires 2711P-RN6, -RN6K
1761-CBL-AS03 (3 m/10 ft)
1761-CBL-AS09 (9 m/30 ft)
Use AIC+ module(1761-NET-AIC)
to connect to Port 3
1761-CBL-AS03 (3 m/10 ft)
1761-CBL-AS09 (9 m/30 ft)
— —
ControlNet
ControlNet portPanelView Plus 400 and 600Requires 2711P-RN15CPanelView Plus 700 to 1500Requires 2711P-RN15S, -RN15SK
— — — — —
EtherNet/IP EtherNet/IP portPanelView Plus 400 to 1500
— Use 1761-NET-ENI modulewith Ethernet cable
— —1585J-M type cable or
2711P-CBL-EX04 (4 m/14 ft) (2)
DH+ DH+ portPanelView Plus 400 and 600Requires 2711P-RN8PanelView Plus 700 to 1500Requires 2711P-RN6, -RN6K
— ——
shieldedtwinaxial
cable (1770-CD)
—
(1) For CE compliance, use the 1761-NET-AIC or 1747-AIC module for cable lengths longer than 30 m (98 ft).(2) EtherNet/IP direct connection from the terminal to an SLC 5/05 controller requires an Ethernet switch or the 2711P-CBL-EX04 crossover cable.
Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010
24 PanelView Plus Specificationswww.klinkmann.com
6 / 2011
Table 45 - Runtime Communication Cables: PanelView Plus Terminals to PLC-5 and MicroLogix Controllers
Protocol PanelView Plus Comm Port400, 600, 700, 1000, 1250, 1500
PLC-5, PLC-5C, PLC-5ECH0 (25-pin RS-232)
(DF1)
MicroLogix 1400, 1500LRPCH1/CH2 (9-pin RS-232)
(DF1 or DH-485)
MicroLogix 1000, 1100, 1200, 1400, 1500LSP
CH0 (8-pin Mini DIN)(DF1 or DH-485)
MicroLogix 1100, 1400 Ethernet
DF1 RS-232 (DF1) port (9-pin)PanelView Plus 400 to 15002711P-RN22C (for 400 and 600 only)
2711-NC13 (5 m/16 ft)2711-NC14 (10 m/32 ft)
(9-to-25 pin adapter required)
2711-NC13 (5 m/16 ft)2711-NC14 (10 m/32 ft)
2711-NC21 (5 m/16 ft)2711-NC22 (15 m/49 ft) (3)
—
DH-485
RS-232 (DH-485) port (9-pin)PanelView Plus 400 to 15002711P-RN22C (for 400 and 600 only)
— 2711-NC13 (5 m/16 ft)2711-NC14 (10 m/32 ft)
2711-NC21 (5 m/16 ft)2711-NC22 (15 m/49 ft)
—
DH-485 portPanelView Plus 400 and 600Requires 2711P-RN3(1)
PanelView Plus 700 to 1500Requires 2711P-RN6, -RN6K
— —Use AIC+ module(1761-NET-AIC)
to connect to Port 3—
ControlNet
ControlNet portPanelView Plus 400 and 600Requires 2711P-RN15CPanelView Plus 400 to 1500Requires 2711P-RN15S, -RN15SK
To PLC-5C with ControlNet cable
— — —
EtherNet/IPEtherNet/IP portPanelView Plus 400 to 1500
To PLC-5E with1585J-M type cable or
2711P- CBL-EX04 (4 m/14 ft) (2)
Use 1761-NET-ENI modulewith Ethernet cable
1585J-M type cable or 2711P- CBL-EX04 (4 m/14 ft) (2)
DH+ DH+ portPanelView Plus 400 and 600Requires 2711P-RN8PanelView Plus 700 to 1500Requires 2711P-RN6, -RN6K
shielded twinaxial cable(1770-CD)
— — —
(1) For CE compliance, use the 1761-NET-AIC or 1747-AIC module for cable lengths longer than 30 m (98 ft).(2) For a direct connection between the terminal and the controller use the 2711P-CBL-EX04 crossover cable.(3) The AIC+ module is recommended for isolation purposes when the terminal and controller are not on same power supply.
Table 46 - Runtime Communication Cables: PanelView Plus Terminals to Logix Controllers
Protocol PanelView Plus Comm Port400, 600, 700, 1000, 1250, 1500
ControlLogixCH0 (9-pin RS-232)
(DF1)
CompactLogixCH0 (9-pin RS-232)
(DF1 or DH-485)
DF1 RS-232 (DF1) port (9-pin)PanelView Plus 400 to 15002711P-RN22C (for 400 and 600 only)
2711-NC13 (5 m/16 ft)2711-NC14 (10 m/32 ft)2706-NC13 (3 m/10 ft)
DH-485
RS-232 (DH-485) port (9-pin)PanelView Plus 400 to 15002711P-RN22C (for 400 and 600 only)
— 2711-NC13 (5 m/16 ft)2711-NC14 (10 m/32 ft)2706-NC13 (3 m/10 ft)
DH-485 portPanelView Plus 400 and 600 requires 2711P-RN3(1)
PanelView Plus 700 to 1500 requires 2711P-RN6, -RN6K—
Use AIC+ module(1761-NET-AIC)
to connect to port 3
ControlNetControlNet portPanelView Plus 400 and 600 requires 2711P-RN15CPanelView Plus 700 to 1500 requires 2711P-RN15S, -RN15SK
Use 1756-CNB module with ControlNet cable1769-L35CR, 1769-L32C, 1768-CNB, or 1768-CNBR
with ControlNet cable
EtherNet/IPEtherNet/IP portPanelView Plus 400 to 1500
Use 1756-EN2T or 1756-ENBT module with1585J-M type cable or
2711P- CBL-EX04 (4 m/14 ft)(2)
To 1769-L35E, 1769-L23E, 1769-L32E, or 1768-ENBT module with 1585J-M type cable
or 2711P- CBL-EX04 (4 m/14 ft)(2)
DH+ DH+ portPanelView Plus 400 and 600 requires 2711P-RN8PanelView Plus 700 to 1500 requires 2711P-RN6, -RN6K
Use 1756-DHRIO module withshielded twinaxial cable (1770-CD) —
(1) For CE compliance, use the 1761-NET-AIC or 1747-AIC module for cable lengths longer than 30 m (98 ft).(2) For a direct connection between the terminal and controller, use the 2711P-CBL-EX04 crossover cable.
Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010
PanelView Plus Specifications 25www.klinkmann.com6 / 2011
PanelView Plus Compact Runtime Cables
Tables 48…51 list cables required to connect PanelView Plus Compact terminals to controllers and interface modules for runtime operations.
Table 47 - Runtime Communication Cables: PanelView Plus Terminals to Interface Modules
Protocol PanelView Plus Comm Port400, 600, 700, 1000, 1250, 1500 1747-AIC
1761-NET-AIC 1771-NET-ENI
Port 1 (9-pin) Port 2(8-pin Mini DIN)
Port 3(DH-485)
Port 2(8-pin Mini DIN)
DF1 RS-232 port (9-pin)PanelView Plus 400 to 15002711P-RN22C (for 400 and 600)
— 2711-NC13 (5 m/16 ft)2711-NC14 (10 m/32 ft)
2711-NC21 (5 m/16 ft)2711-NC22 (15 m/49 ft)
Null modem required—
1761-CBL-AP00 (5 m)1761-CBL-PM02 (2 m)2711-CBL-PM05 (5 m)
2711-CBL-PM10 (10 m)
DH-485
RS-232 port (9-pin)PanelView Plus 400 to 15002711P-RN22C (for 400 and 600)
— 2711-NC13 (5 m/16 ft)2711-NC14 (10 m/32 ft)
2711-NC21 (5 m/16 ft)2711-NC22 (15 m/49 ft)
Null modem required—
DH-485 portPanelView Plus 400 and 600Requires 2711P-RN3(1)
1747-C10 (2 m/6ft) 1747-C11 (0.3 m/1 ft)1747-C20 (6 m/20 ft)
— — 1761-CBL-AS03 (3 m/10 ft)1761-CBL-AS09 (9 m/30 ft)
to single AIC+
—
DH-485 portPanelView Plus 700 to 1500Requires 2711P-RN6, -RN6K
Direct connection to single AIC with
Belden 9842 cable(2)— —
Direct connection to single AIC+ with
Belden 9842 cable(2)—
(1) For CE compliance, use the 1761-NET-AIC or 1747-AIC module for cable lengths longer than 30 m (98 ft).(2) Use serial port on the PanelView Plus terminal with an AIC+ module for a DH-485 network solution.
Table 48 - Runtime Communication Cables: PanelView Plus Compact Terminals to SLC Controllers
Protocol PanelView Plus Compact400, 600, 1000 Comm Port
SLC-500, 5/01, 5/02CH1 RJ45 (DH-485)
SLC-5/03, 5/04, 5/05CH0 (9-pin RS-232)
(DF1 or DH-485)
SLC 5/03CH1 (RJ45)
(DH-485)SLC 5/04
CH1 (DH+)SLC 5/05
CH1 (ENET)
DF1 RS-232 (DF1) Comm port (9-pin) — 2711-NC13 (5 m/16 ft)2711-NC14 (10 m/32 ft) —
— —
DH-485 RS-232 (DH-485) Comm port (9-pin)Use AIC+ module(1761-NET-AIC)
to connect to port 1 or 2
2711-NC13 (5 m/16 ft)2711-NC14 (10 m/32 ft)
Use AIC+ module(1761-NET-AIC)
to connect to port 1 or 2— —
EtherNet/IP EtherNet/IP Comm port — Use 1761-NET-ENI modulewith Ethernet cable — — 2711P- CBL-EX04 Ethernet
crossover cable (1)
(1) An EtherNet/IP direction connection between a PanelView Plus Compact terminal and an SLC 5/05 requires hub or crossover cable listed.
Table 49 - Runtime Communication Cables: PanelView Plus Compact Terminals to MicroLogix Controllers
Protocol PanelView Plus Compact400, 600, 1000 Comm Port
MicroLogix 1500LRPCH1 (9-pin RS-232)
(DF1 or DH-485)
MicroLogix 1000, 1200, 1500LSPCH0 (8-pin Mini DIN)
(DF1 or DH-485)MicroLogix 1100, 1400
Ethernet Port
DF1 RS-232 (DF1) Comm port (9-pin)2711-NC13 (5 m/16 ft)
2711-NC14 (10 m/32 ft)2711-NC21 (5 m/16 ft)
2711-NC22 (15 m/49 ft) (1) —
DH-485 RS-232 (DH-485) Comm port (9-pin)2711-NC13 (5 m/16 ft)
2711-NC14 (10 m/32 ft)2711-NC21 (5 m/16 ft)
2711-NC22 (15 m/49 ft) (1) —
EtherNet/IP EtherNet/IP Comm portUse 1761-NET-ENI module
with Ethernet cable1585J-M type cable or
2711P-CBL-EX04 cable (4 m/14 ft)(2)
(1) AIC+ Module recommended for isolation when PanelView and controller are not using same power supply.(2) For a direct connection between the terminal and controller, use the 2711P-CBL-EX04 crossover cable
Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010
26 PanelView Plus Specificationswww.klinkmann.com
6 / 2011
Table 50 - Runtime Communication Cables: PanelView Plus Compact to Logix Controllers
Protocol PanelView Plus Compact400, 600, 1000 Comm Port
ControlLogixCH0 (9-pin RS-232)
(DF1)
CompactLogixCH0 (9-pin RS-232)
(DF1 or DH-485)
DF1 RS-232 (DF1) Comm port (9-pin)2711-NC13 (5 m/16 ft)
2711-NC14 (10 m/32 ft)
DH-485 RS-232 (DH-485) Comm port (9-pin) — 2711-NC13 (5 m/16 ft)2711-NC14 (10 m/32 ft)
EtherNet/IP EtherNet/IP Comm portUse 1756-EN2T or 1756-ENBT module
with 1585J-M type cable or 2711P-CBL-EX04 cable (4 m/14 ft)(1)
To 1769-L35E, L23E, L32E with1585J-M type cable or
2711P-CBL-EX04 cable (4 m/14 ft)(1)
(1) For a direct connection between the terminal and controller, use the 2711P-CBL-EX04 crossover cable.
Table 51 - Runtime Communication Cables: PanelView Plus Compact to Network Modules
Protocol PanelView Plus Compact400, 600, 1000 Comm Port
1761-NET-AIC
Port 1 (9-pin) Port 28-pin Mini DIN
Port 3(DH-485)
DF1 RS-232 Comm port (9-pin)2711-NC13 (5 m/16 ft)2711-NC14 (10 m/32 ft)
2711-NC21 (5 m/16 ft)2711-NC22 (15 m/49 ft)
—
DH-485 RS-232 Comm port (9-pin)2711-NC13 (5 m/16 ft)2711-NC14 (10 m/32 ft)
2711-NC21 (5 m/16 ft)2711-NC22 (15 m/49 ft) —
Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010
PanelView Plus Specifications 27www.klinkmann.com6 / 2011
Migration Hardware The PanelView Plus platforms provide a clear migration path for replacing older terminals. When migrating to a new platform, consider both the display size and the unit size. PanelView Plus terminals uses the same panel cutouts as existing PanelView products, yet offer a larger display. For instance, a PanelView Plus 6, 1250 terminal with a 12.1-inch display fits into the same cutout as a PanelView 1000 or 1000e with a 10.4-inch display. When choosing a terminal with the same display size, adapter plates are used to adapt the cutout of the new terminal.
Table 52 - PanelView Plus Replacement Terminals
PanelView Standard Terminal PanelView Plus Replacement Terminal Adapter Plate Required
Adapter Plate Cat. No.
PanelView Standard 300 or 300 Micro None available(1) — —
PanelView 550 or 600 touch PanelView Plus or PanelView Plus Compact 400 keypad or keypad/touchPanelView Plus or PanelView Plus Compact 600 touch No —
PanelView 550 keypadPanelView 550 keypad/touch
PanelView Plus 600 keypad or keypad/touch No —
PanelView Plus PanelView Plus Compact 400 keypad or keypad/touchPanelView Plus PanelView Plus Compact 600 touch Yes 2711P-RAK4
PanelView 600 keypadPanelView 600 keypad/touch
PanelView Plus 600 keypad or keypad/touch Yes 2711P-RAK6
PanelView Plus 6, 700 keypad or keypad/touch No —
PanelView 900 keypadPanelView Plus 6, 700 keypad or keypad/touch Yes 2711P-RAK7
PanelView Plus 6, 1000 keypad or keypad/touch No —
PanelView 900 touchPanelView Plus 6, 700 touch Yes 2711P-RAT7
PanelView Plus 6 or PanelView Plus Compact 1000 touch No —
PanelView 1000 keypadPanelView Plus 6, 1000 keypad or keypad/touch Yes 2711P-RAK10
PanelView Plus 6, 1250 keypad or keypad/touch No —
PanelView 1000 touchPanelView Plus 6 or PanelView Plus Compact 1000 touch Yes 2711P-RAT10
PanelView Plus 6, 1250 touch No —
PanelView 1400 keypadPanelView Plus 6, 1250 keypad or keypad/touch Yes 2711P-RAK12S
PanelView Plus 6, 1500 keypad or keypad/touch No —
PanelView1400e keypadPanelView Plus 6, 1500 keypad or keypad/touch(2) Yes 2711P-RAK15
None available — —
PanelView 1400 touch PanelView Plus 6, 1250 touch Yes 2711P-RAT12S
PanelView Plus 6, 1500 touch No —
PanelView 1400e touchPanelView Plus 6,1500 touch(2) Yes 2711P-RAT15
None available — —
PanelView 1200, 1200e/1400e Keypad PanelView Plus 6,1250 keypad(2) Yes RAK12E
None available — —
PanelView 1200, 1200e Touch PanelView Plus 6,1250 touch(3) Yes RAT12E
None available — —
PanelView 1200/1200E touch PanelView Plus 6,1250 touch(3) Yes 2711P-RAT12E2
None available — —
(1) Replace the PanelView Standard 300 or 300 Micro with a PanelView Plus 400 keypad terminal by increasing the size of the current panel cutout.(2) Adapter plate required for stud-mounted terminals.(3) Requires modification of panel cutout.
Rockwell Automation Publication 2711P-TD005A-EN-P - November 2010
28 PanelView Plus Specifications
611.pdf
Rigatel. +klink
.ua
Additional Resources These documents contain additional information concerning related Rockwell Automation products.
You can view or download publications at http://www.rockwellautomation.com/literature/. To order paper copies of technical documentation, contact your local Rockwell Automation distributor or sales representative.
Resource Description
Visualization Solutions Selection Guide, publication VIEW-SG001
Provides an overview of the visualization products including catalog number selections offered by Rockwell Automation.
PanelView 6 Terminals User Manual, publication 2711P-UM006
Provides information on how to install, configure, operate, and troubleshoot the PanelView Plus 6 (700 to 1500) terminals.
PanelView Plus 6 Terminals Installation Instructions, publication 2711P-IN029
Provides information on how to install the PanelView Plus 6 (700 to 1500) terminals in a panel.
PanelView Plus Compact Terminals User Manual, publication 2711PC-UM001
Provides information on how to install, configure, operate, and troubleshoot the PanelView Plus Compact terminals.
PanelView Plus Terminals User Manual, publication 2711P-UM001
Provides information on how to install, configure, operate, and troubleshoot the PanelView Plus 400 and 600 terminals.
Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1
Provides general guidelines for installing a Rockwell Automation industrial system.
Product Certifications website, http://www.ab.com
Provides declarations of conformity, certificates, and other certification details.
Publication 2711P-TD005A-EN-P - November 2010 Copyright © 2010 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.
Rockwell_Operator_Interface_PanelView_Plus_Specifications_Tech_Data_en_0
Samaratel. +7 846 273 95 [email protected]
Yekaterinburgtel. +7 343 376 [email protected]
St. Petersburgtel. +7 812 327 [email protected]
Moscowtel. +7 495 641 [email protected]
Helsinkitel. +358 9 540 [email protected]
Vilnius МinskTallinn
Кievtel. +38 044 495 33 [email protected]
www.klinkmann.com
tel. +370 5 215 [email protected]
371 6738 [email protected]
tel. +375 17 200 [email protected]
tel. +372 668 [email protected]