Overview to Designing P25 Overview to Designing P25 SystemsSystems
IntroductionIntroduction
-
Objectives ...Objectives ... Explain Project 25 and its system requirements.Explain Project 25 and its system requirements. Explain the new technology and concepts required for P25 Explain the new technology and concepts required for P25
systems.systems. At a high level, explain the following for P25 releases:At a high level, explain the following for P25 releases:
Physical architecture and topologiesPhysical architecture and topologies General system flowGeneral system flow Network managementNetwork management FeaturesFeatures
Compare P25 releases to non P25 compliant platform Compare P25 releases to non P25 compliant platform alternatives.alternatives.
Compare P25 releases to competitive P25 platforms.Compare P25 releases to competitive P25 platforms. At a high level, explain the migration paths and strategies At a high level, explain the migration paths and strategies
from existing SmartZone and OmniLink systems to ASTRO from existing SmartZone and OmniLink systems to ASTRO 4.1 systems.4.1 systems.
-
Course Map ...Course Map ...Evolution of
Project 25
ASTROP25 Systems
PlatformComparisons
SupportingASTRO 4.1
Systems
Migration
-
Module 1Module 1Evolution of Project 25Evolution of Project 25
-
Project 25The New Standard for Public Safety
Digital Communications
-
The Standard Reflects the Contributions The Standard Reflects the Contributions of Manyof Many
Motorolas CommitmentsMotorolas Commitments Support for Project 25Support for Project 25 Support for UserSupport for User--Driven StandardsDriven Standards Support for Public Safety ProfessionalsSupport for Public Safety Professionals
ContributionsContributions
-
Project 25 HISTORY
19901990 19911991 19921992 19931993
HistoryHistory
The New Standard is a The New Standard is a Communications MilestoneCommunications Milestone
AnalogTrunkingStd Effort
DigitalProposals
CAIAdopted
TIABalloting
TrunkingProposals
AccessAdopted
ModulationProven
Modulation& VocoderAdopted
VocoderTest Protocol
Complete
-
1974 1978 1982 1986 1990
APCO 16INITIATED
Project 25INITIATED
APCO 16COMPLETED
1984 1992
1993 1995 1997 1999 2001
Project 25Project 25Interim ReportsInterim Reports
2003
CAI Adopted 11/93
APCO Project 25 and APCO 16 time line
STD COMPLETED 1/96Phase 1 Adopted 8/95
1974 1978 1982 1986 1990
APCO 16INITIATED
Project 25INITIATED
APCO 16APCO 16COMPLETEDCOMPLETED
1984 1992
SmartNet ASTRO
1993 1995 1997 1999 2001
Project 25Project 25Interim ReportsInterim Reports
2003
CAI Adopted 11/93CAI Adopted 11/93
Project 25 and APCO 16 time line
STD COMPLETED 1/96STD COMPLETED 1/96Phase 1 Adopted 8/95Phase 1 Adopted 8/95
TimelineTimeline
The Standard Process Built on the The Standard Process Built on the APCO Project 16 Experience APCO Project 16 Experience
-
BenefitsBenefits
The Standards Benefits are The Standards Benefits are ConsiderableConsiderable InteroperabilityInteroperability UserUser--driven Standardsdriven Standards Graceful MigrationGraceful Migration Spectrum EfficiencySpectrum Efficiency Enhanced FunctionalityEnhanced Functionality
-
Project 25 ObjectivesProject 25 Objectives
Work Began with User Objectives Work Began with User Objectives Clearly DefinedClearly Defined Open System ArchitectureOpen System Architecture Increased Spectrum EfficiencyIncreased Spectrum Efficiency Backward CompatibilityBackward Compatibility Forward MigratabilityForward Migratability
-
The ResultThe Result The Interfaces for The Interfaces for
the New Standardthe New Standard Common Air Common Air
Interface Interface Data Air InterfaceData Air Interface Inter System Inter System
InterfaceInterface Host Data InterfaceHost Data Interface InterconnectInterconnect Network Network
ManagementManagement
Crucial Parameters Crucial Parameters are In Placeare In Place Access MethodAccess Method VocoderVocoder Modulation System Modulation System Encryption Encryption Trunking ProtocolTrunking Protocol
-
Other Systems
Host
Gateway
Network Manager
Consoles
Subscriber Units
Repeaters
PSTN
Inter-SystemInter-SystemInterfaceInterface
Interconnect Interconnect (PSTN)(PSTN)
Data Air Data Air InterfaceInterface
Network Network ManagementManagement
Common Air Common Air Interface Interface
C.A.I.C.A.I.
Host Data Host Data InterfaceInterface
System InterfacesSystem Interfaces
-
Fundamental User BenefitsFundamental User Benefits
Digital InteroperabilityDigital Interoperability
-
INTEGRATED DATA & VOICEINTEGRATED DATA & VOICE
D
A
T
A
D
A
T
A
D
A
T
A
Voice Voice 12.5 kHz Channel
Data / voiceRadio
Voice Radio
Voice Radio
Fundamental User BenefitsFundamental User BenefitsGreater Spectrum Efficiency Through Greater Spectrum Efficiency Through
Narrower Channels Using Digital Narrower Channels Using Digital TechnologyTechnology
-
Fundamental User BenefitsFundamental User Benefits
Backward CompatibilityBackward Compatibility
ASTRODigital
SubscriberRadio
25 kHzanalog
Stat-Alert 25 kHzSecurenet
25 kHzAdvancedSecurenet
25 kHzanalog
SmartNet12.5 kHzdigital,
clear or encrypted
12.5 kHzanalog
25 kHzanalog
12.5 kHzanalog/digital
SmartNet
-
SPECTRUMSPECTRUM
Migration 25 to 12.5 to 6.25 kHzMigration 25 to 12.5 to 6.25 kHz
APCO-25Digital
FutureGeneration
25kHz 12.5kHz 6.25kHz
Fundamental User BenefitsFundamental User Benefits
Forward MigratabilityForward Migratability
-
VendorsVendors
12 vendors have participated in the 12 vendors have participated in the Project 25 processProject 25 process
6 offer or plan to offer CAI compatible 6 offer or plan to offer CAI compatible subscriber unitssubscriber units
At least 2 vendors (other than Motorola) At least 2 vendors (other than Motorola) offer CAI compatible stationsoffer CAI compatible stations
-
Toward the future ...Toward the future ...
Phase I is completePhase I is complete Phase II is in processPhase II is in process
-
These are These are FUTUREFUTURE issuesissues
Today, most systems are still analogToday, most systems are still analogMost analog systems are still Most analog systems are still
conventionalconventionalMarket challenge and focus of this Market challenge and focus of this
class is move toward digital and class is move toward digital and trunked/sharedtrunked/shared
-
Module 2Module 2ASTRO P25 SystemsASTRO P25 Systems
ASTRO 6.0ASTRO 6.0
-
Next GenerationNext GenerationTransport Core Transport Core
OverviewOverview
-
NextNext--Generation Transport Generation Transport Core ... The MissionCore ... The Mission Create a Large System solution for the Create a Large System solution for the
Public Safety MarketPublic Safety Market Scalable Platform Solution for Large Scalable Platform Solution for Large
SystemsSystems Integrated Data and Voice ServicesIntegrated Data and Voice Services Packet based Console Dispatch PositionPacket based Console Dispatch Position New System Services/functionality New System Services/functionality
beyond scalable transportbeyond scalable transport
-
General Capabilities some General Capabilities some not available in first releasenot available in first release Digital only platformDigital only platform Project 25 protocolsProject 25 protocols Large number of sites/zonesLarge number of sites/zones Scaleable down to a single zoneScaleable down to a single zone Integrated voice and dataIntegrated voice and data PacketPacket--based networkingbased networking New Console architectureNew Console architecture
no AEB/CEBno AEB/CEB
-
Transport BandwidthTransport BandwidthVoice call 1Voice call 2Circuit data 1...
Voice call 1Voice call 2Circuit data 1Packet dataNetwork Mgmt...
New Transport Paradigm
Old Transport Approach
-
Key Architectural Aspects Key Architectural Aspects 1.1. Internet Protocol (IP) based InfrastructureInternet Protocol (IP) based Infrastructure
PSTN
ZoneControllers
PacketData G/W
(Hardware Only)
TelephonyG/W(R6.0)
ZoneNetwork Management System
Servers/Consoles
Co-locatedSystem NMS
Servers/Consoles
Other MSO(s)
S400Site RouterS594Core Routers
Rendezvous RoutersExit Routers
S400Site Router
S500Data Router
Nortel Passport 7400WAN Switch
Cisco 6509Catalyst
LAN Switch
IMA
IMA
Dispatch Site(Gold Console R6.0)
MGEG
AEB
CEB
S500MGEG Router
S500Control Router
S400Site Router
S1100Switch
Conventional/Mutual Aid
DACS
1
-
PSTN
ZoneControllers
PacketData G/W
(Hardware Only)
TelephonyG/W(R6.0)
ZoneNetwork Management System
Servers/Consoles
Co-locatedSystem NMS
Servers/Consoles
Other MSO(s)
S400Site RouterS594Core Routers
Rendezvous RoutersExit Routers
S400Site Router
S500Data Router
Nortel Passport 7400WAN Switch
Cisco 6509Catalyst
LAN Switch
IMA
IMA
Dispatch Site(Gold Console R6.0)
MGEG
AEB
CEB
S500MGEG Router
S500Control Router
S400Site Router
S1100Switch
Conventional/Mutual Aid
DACS
Key Architectural Aspects Key Architectural Aspects 2.2. Retain Retain SmartZoneSmartZone / / OmniLinkOmniLink call call processing and servicesprocessing and services
2
-
Key Architectural Aspects Key Architectural Aspects 3.3. End to EndEnd to End TranscodingTranscoding and Encryption and Encryption
PSTN
ZoneControllers
PacketData G/W
(Hardware Only)
TelephonyG/W(R6.0)
ZoneNetwork Management System
Servers/Consoles
Co-locatedSystem NMS
Servers/Consoles
Other MSO(s)
S400Site RouterS594Core Routers
Rendezvous RoutersExit Routers
S400Site Router
S500Data Router
Nortel Passport 7400WAN Switch
Cisco 6509Catalyst
LAN Switch
IMA
IMA
Dispatch Site(Gold Console R6.0)
MGEG
AEB
CEB
S500MGEG Router
S500Control Router
S400Site Router
S1100Switch
Conventional/Mutual Aid
DACS
3
-
Key Architectural Aspects Key Architectural Aspects 4.4. Independent air interfaceIndependent air interface
PSTN
ZoneControllers
PacketData G/W
(Hardware Only)
TelephonyG/W(R6.0)
ZoneNetwork Management System
Servers/Consoles
Co-locatedSystem NMS
Servers/Consoles
Other MSO(s)
S400Site RouterS594Core Routers
Rendezvous RoutersExit Routers
S400Site Router
S500Data Router
Nortel Passport 7400WAN Switch
Cisco 6509Catalyst
LAN Switch
IMA
IMA
Dispatch Site(Gold Console R6.0)
MGEG
AEB
CEB
S500MGEG Router
S500Control Router
S400Site Router
S1100Switch
Conventional/Mutual Aid
DACS
4
-
Release 6.0Release 6.0Primary ComponentsPrimary Components
-
Conceptual ASTROConceptual ASTRO 25 Physical 25 Physical ArchitectureArchitecture
PSTN
ZoneControllers
PacketData G/W
(Hardware Only)
TelephonyG/W(R6.0)
ZoneNetwork Management System
Servers/Consoles
Co-locatedSystem NMS
Servers/Consoles
Other MSO(s)
S400Site RouterS594Core Routers
Rendezvous RoutersExit Routers
S400Site Router
S500Data Router
Nortel Passport 7400WAN Switch
Cisco 6509Catalyst
LAN Switch
IMA
IMA
Dispatch Site(Gold Console R6.0)
MGEG
AEB
CEB
S500MGEG Router
S500Control Router
S400Site Router
S1100Switch
Conventional/Mutual Aid
DACS
-
ASTROASTRO 25 Master Site25 Master Site
MGEG
CORE ROUTERS
EXITROUTERS
WAN SWITCH
PACKET DATA GATEWAY
ZDS
ZSS
ATR
UCS
FVS
SSS
PC UserTerminal
LAN SWITCH
AEB
ELITECONSOLES
ZONE CONTROLLER
1
ZONECONTROLLER
2
INTERFACESWITCH
WITHIP
CONTROL
CALL PROCESSING SUBSYSTEM
CEB
ELITECONSOLES
LANSWITCH
SITEROUTER
DATAROUTERS
MGEGROUTERS
TO REMOTE SITES
Digital Cross Connect Switch
PBXTELEPHONEINT. SERVER
CONTROLROUTERS
WAN SWITCH MGMT.
NETWORKPERFORMANCE
MGMT.
LAN SWITCHMGMT. MOSCAD NETWORK
FAULT MGMT.
ANALOGREMOTEACCESS
DIGITALREMOTEACCESS
Network Management
NTP SERVER
TO OTHERZONES
ZONE OSS
SYSTEMOSS
-
ASTROASTRO 25 Master Site25 Master Site
MGEG
CORE ROUTERS
EXITROUTERS
WAN SWITCH
PACKET DATA GATEWAY
ZDS
ZSS
ATR
UCS
FVS
SSS
PC UserTerminal
LAN SWITCH
AEB
ELITECONSOLES
ZONE CONTROLLER
1
ZONECONTROLLER
2
INTERFACESWITCH
WITHIP
CONTROL
CALL PROCESSING SUBSYSTEM
CEB
ELITECONSOLES
LANSWITCH
SITEROUTER
DATAROUTERS
MGEGROUTERS
TO REMOTE SITES
Digital Cross Connect Switch
PBXTELEPHONEINT. SERVER
CONTROLROUTERS
WAN SWITCH MGMT.
NETWORKPERFORMANCE
MGMT.
LAN SWITCHMGMT. MOSCAD NETWORK
FAULT MGMT.
ANALOGREMOTEACCESS
DIGITALREMOTEACCESS
Network Management
NTP SERVER
TO OTHERZONES
ZONE OSS
SYSTEMOSS
-
ASTROASTRO 25 Master Site25 Master Site
MGEG
CORE ROUTERS
EXITROUTERS
WAN SWITCH
PACKET DATA GATEWAY
ZDS
ZSS
ATR
UCS
FVS
SSS
PC UserTerminal
LAN SWITCH
AEB
ELITECONSOLES
ZONE CONTROLLER
1
ZONECONTROLLER
2
INTERFACESWITCH
WITHIP
CONTROL
CALL PROCESSING SUBSYSTEM
CEB
ELITECONSOLES
LANSWITCH
SITEROUTER
DATAROUTERS
MGEGROUTERS
TO REMOTE SITES
Digital Cross Connect Switch
PBXTELEPHONEINT. SERVER
CONTROLROUTERS
WAN SWITCH MGMT.
NETWORKPERFORMANCE
MGMT.
LAN SWITCHMGMT. MOSCAD NETWORK
FAULT MGMT.
ANALOGREMOTEACCESS
DIGITALREMOTEACCESS
Network Management
NTP SERVER
TO OTHERZONES
ZONE OSS
SYSTEMOSS
-
ASTROASTRO 25 Master Site25 Master Site
MGEG
CORE ROUTERS
EXITROUTERS
WAN SWITCH
PACKET DATA GATEWAY
ZDS
ZSS
ATR
UCS
FVS
SSS
PC UserTerminal
LAN SWITCH
AEB
ELITECONSOLES
ZONE CONTROLLER
1
ZONECONTROLLER
2
INTERFACESWITCH
WITHIP
CONTROL
CALL PROCESSING SUBSYSTEM
CEB
ELITECONSOLES
LANSWITCH
SITEROUTER
DATAROUTERS
MGEGROUTERS
TO REMOTE SITES
Digital Cross Connect Switch
PBXTELEPHONEINT. SERVER
CONTROLROUTERS
WAN SWITCH MGMT.
NETWORKPERFORMANCE
MGMT.
LAN SWITCHMGMT. MOSCAD NETWORK
FAULT MGMT.
ANALOGREMOTEACCESS
DIGITALREMOTEACCESS
Network Management
NTP SERVER
TO OTHERZONES
ZONE OSS
SYSTEMOSS
-
ASTROASTRO 25 Master Site25 Master Site
MGEG
CORE ROUTERS
EXITROUTERS
WAN SWITCH
PACKET DATA GATEWAY
ZDS
ZSS
ATR
UCS
FVS
SSS
PC UserTerminal
LAN SWITCH
AEB
ELITECONSOLES
ZONE CONTROLLER
1
ZONECONTROLLER
2
INTERFACESWITCH
WITHIP
CONTROL
CALL PROCESSING SUBSYSTEM
CEB
ELITECONSOLES
LANSWITCH
SITEROUTER
DATAROUTERS
MGEGROUTERS
TO REMOTE SITES
Digital Cross Connect Switch
PBXTELEPHONEINT. SERVER
CONTROLROUTERS
WAN SWITCH MGMT.
NETWORKPERFORMANCE
MGMT.
LAN SWITCHMGMT. MOSCAD NETWORK
FAULT MGMT.
ANALOGREMOTEACCESS
DIGITALREMOTEACCESS
Network Management
NTP SERVER
TO OTHERZONES
ZONE OSS
SYSTEMOSS
-
ASTROASTRO 25 Master Site25 Master Site
MGEG
CORE ROUTERS
EXITROUTERS
WAN SWITCH
PACKET DATA GATEWAY
ZDS
ZSS
ATR
UCS
FVS
SSS
PC UserTerminal
LAN SWITCH
AEB
ELITECONSOLES
ZONE CONTROLLER
1
ZONECONTROLLER
2
INTERFACESWITCH
WITHIP
CONTROL
CALL PROCESSING SUBSYSTEM
CEB
ELITECONSOLES
LANSWITCH
SITEROUTER
DATAROUTERS
MGEGROUTERS
TO REMOTE SITES
Digital Cross Connect Switch
PBXTELEPHONEINT. SERVER
CONTROLROUTERS
WAN SWITCH MGMT.
NETWORKPERFORMANCE
MGMT.
LAN SWITCHMGMT. MOSCAD NETWORK
FAULT MGMT.
ANALOGREMOTEACCESS
DIGITALREMOTEACCESS
Network Management
NTP SERVER
TO OTHERZONES
ZONE OSS
SYSTEMOSS
-
ASTROASTRO 25 Master Site25 Master Site
MGEG
CORE ROUTERS
EXITROUTERS
WAN SWITCH
PACKET DATA GATEWAY
ZDS
ZSS
ATR
UCS
FVS
SSS
PC UserTerminal
LAN SWITCH
AEB
ELITECONSOLES
ZONE CONTROLLER
1
ZONECONTROLLER
2
INTERFACESWITCH
WITHIP
CONTROL
CALL PROCESSING SUBSYSTEM
CEB
ELITECONSOLES
LANSWITCH
SITEROUTER
DATAROUTERS
MGEGROUTERS
TO REMOTE SITES
Digital Cross Connect Switch
PBXTELEPHONEINT. SERVER
CONTROLROUTERS
WAN SWITCH MGMT.
NETWORKPERFORMANCE
MGMT.
LAN SWITCHMGMT. MOSCAD NETWORK
FAULT MGMT.
ANALOGREMOTEACCESS
DIGITALREMOTEACCESS
Network Management
NTP SERVER
TO OTHERZONES
ZONE OSS
SYSTEMOSS
-
ASTROASTRO 25 Master Site25 Master Site
Next Generation Next Generation NMSNMS
ZDS
ZSS
ATR
UCS
FVS
SSS
PC UserTerminal
WAN SWITCH MGMT.
NETWORKPERFORMANCE
MGMT.
LAN SWITCHMGMT.
Network Management
ZONE OSS
SYSTEMOSS
-
ASTROASTRO 25 Master Site25 Master Site
ZDS
ZSS
ATR
UCS
FVS
SSS
PC UserTerminal
WAN SWITCH MGMT.
NETWORKPERFORMANCE
MGMT.
LAN SWITCHMGMT.
Network Management
ZONE OSS
SYSTEMOSS
Next Generation Next Generation NMSNMS Client/Server Client/Server
NetworkingNetworking
-
ASTROASTRO 25 Master Site25 Master Site
ZDS
ZSS
ATR
UCS
FVS
SSS
PC UserTerminal
WAN SWITCH MGMT.
NETWORKPERFORMANCE
MGMT.
LAN SWITCHMGMT.
Network Management
ZONE OSS
SYSTEMOSS
Next Generation Next Generation NMSNMS Client/Server Client/Server
NetworkingNetworking WindowsWindows--based based
ClientsClients
-
ASTROASTRO 25 Master Site25 Master Site
ZDS
ZSS
ATR
UCS
FVS
SSS
PC UserTerminal
WAN SWITCH MGMT.
NETWORKPERFORMANCE
MGMT.
LAN SWITCHMGMT.
Network Management
ZONE OSS
SYSTEMOSS
Next Generation Next Generation NMSNMS Client/Server Client/Server
NetworkingNetworking WindowsWindows--based based
ClientsClients cPCI cPCI Server Server
HardwareHardware PC Client HardwarePC Client Hardware
-
ASTROASTRO 25 Master Site25 Master Site
ZDS
ZSS
ATR
UCS
FVS
SSS
PC UserTerminal
WAN SWITCH MGMT.
NETWORKPERFORMANCE
MGMT.
LAN SWITCHMGMT.
Network Management
ZONE OSS
SYSTEMOSS
ZoneZone--Level Servers Level Servers (one each per zone)(one each per zone) Air Traffic RouterAir Traffic Router Zone Database Zone Database
ServerServer
-
ASTROASTRO 25 Master Site25 Master Site
ZDS
ZSS
ATR
UCS
FVS
SSS
PC UserTerminal
WAN SWITCH MGMT.
NETWORKPERFORMANCE
MGMT.
LAN SWITCHMGMT.
Network Management
ZONE OSS
SYSTEMOSS
ZoneZone--Level Servers Level Servers (one each per zone)(one each per zone) Air Traffic RouterAir Traffic Router Zone Database Zone Database
ServerServer FullVision FullVision INM INM
ServerServer Zone Statistics Zone Statistics
ServerServer
-
ASTROASTRO 25 Master Site25 Master Site
ZDS
ZSS
ATR
UCS
FVS
SSS
PC UserTerminal
WAN SWITCH MGMT.
NETWORKPERFORMANCE
MGMT.
LAN SWITCHMGMT.
Network Management
ZONE OSS
SYSTEMOSS
SystemSystem--Level Level Servers (one per Servers (one per system)system) User Configuration User Configuration
ServerServer System Statistics System Statistics
Server (optional, Server (optional, used on multiused on multi--zone zone systems only)systems only)
WAN Switch WAN Switch Management ServerManagement Server
Ethernet Switch Ethernet Switch Management ServerManagement Server
-
ASTROASTRO 25 Master Site25 Master Site
MGEG
CORE ROUTERS
EXITROUTERS
WAN SWITCH
PACKET DATA GATEWAY
ZDS
ZSS
ATR
UCS
FVS
SSS
PC UserTerminal
LAN SWITCH
AEB
ELITECONSOLES
ZONE CONTROLLER
1
ZONECONTROLLER
2
INTERFACESWITCH
WITHIP
CONTROL
CALL PROCESSING SUBSYSTEM
CEB
ELITECONSOLES
LANSWITCH
SITEROUTER
DATAROUTERS
MGEGROUTERS
TO REMOTE SITES
Digital Cross Connect Switch
PBXTELEPHONEINT. SERVER
CONTROLROUTERS
WAN SWITCH MGMT.
NETWORKPERFORMANCE
MGMT.
LAN SWITCHMGMT. MOSCAD NETWORK
FAULT MGMT.
ANALOGREMOTEACCESS
DIGITALREMOTEACCESS
Network Management
NTP SERVER
TO OTHERZONES
ZONE OSS
SYSTEMOSS
-
ASTROASTRO 25 Master Site25 Master Site
MGEG
CORE ROUTERS
EXITROUTERS
WAN SWITCH
PACKET DATA GATEWAY
ZDS
ZSS
ATR
UCS
FVS
SSS
PC UserTerminal
LAN SWITCH
AEB
ELITECONSOLES
ZONE CONTROLLER
1
ZONECONTROLLER
2
INTERFACESWITCH
WITHIP
CONTROL
CALL PROCESSING SUBSYSTEM
CEB
ELITECONSOLES
LANSWITCH
SITEROUTER
DATAROUTERS
MGEGROUTERS
TO REMOTE SITES
Digital Cross Connect Switch
PBXTELEPHONEINT. SERVER
CONTROLROUTERS
WAN SWITCH MGMT.
NETWORKPERFORMANCE
MGMT.
LAN SWITCHMGMT. MOSCAD NETWORK
FAULT MGMT.
ANALOGREMOTEACCESS
DIGITALREMOTEACCESS
Network Management
NTP SERVER
TO OTHERZONES
ZONE OSS
SYSTEMOSS
-
ASTROASTRO 25 IntelliRepeater 25 IntelliRepeater SiteSite
With Mutual Aid Channel
ChannelBank
Router
Hub
WANSWITCH
T1/FT1
IR IR Conv.Rptr
4W
V.35
10/100 BaseTX
10 Base2
Router
Hub
IR IR
10/100 BaseTX
10 Base2
T1/FT1
-
ASTROASTRO 25 Simulcast Prime 25 Simulcast Prime SiteSite
PrimeSite
Router
LAN Switch2 are required
Site Reference(GPS)
ASTRO-TAC9600 Comparator
CSU
DSX
Channel Bank
SRU
CSU
ASTRO-TAC9600 Comparator
MOSCAD IP RTU
DB9SERIAL
MTC 9600Simulcast
SiteController
MTC 9600Simulcast
SiteController
RemoteSite 1
RemoteSite N.
CSU
4-W E/MDSX
DB9SERIAL
Channel Bank
Mutual AidChannelOptional Mutual Aid
MasterSite
-
PrimeSite
Router
LAN Switch2 are required
Site Reference(GPS)
ASTRO-TAC9600 Comparator
CSU
DSX
Channel Bank
SRU
CSU
ASTRO-TAC9600 Comparator
MOSCAD IP RTU
DB9SERIAL
MTC 9600Simulcast
SiteController
MTC 9600Simulcast
SiteController
RemoteSite 1
RemoteSite N.
CSU
4-W E/MDSX
DB9SERIAL
Channel Bank
Mutual AidChannelOptional Mutual Aid
MasterSite
ASTROASTRO 25 Simulcast Prime 25 Simulcast Prime SiteSite
-
PrimeSite
Router
LAN Switch2 are required
Site Reference(GPS)
ASTRO-TAC9600 Comparator
CSU
DSX
Channel Bank
SRU
CSU
ASTRO-TAC9600 Comparator
MOSCAD IP RTU
DB9SERIAL
MTC 9600Simulcast
SiteController
MTC 9600Simulcast
SiteController
RemoteSite 1
RemoteSite N.
CSU
4-W E/MDSX
DB9SERIAL
Channel Bank
Mutual AidChannelOptional Mutual Aid
MasterSite
ASTROASTRO 25 Simulcast Prime 25 Simulcast Prime SiteSite
-
PrimeSite
Router
LAN Switch2 are required
Site Reference(GPS)
ASTRO-TAC9600 Comparator
CSU
DSX
Channel Bank
SRU
CSU
ASTRO-TAC9600 Comparator
MOSCAD IP RTU
DB9SERIAL
MTC 9600Simulcast
SiteController
MTC 9600Simulcast
SiteController
RemoteSite 1
RemoteSite N.
CSU
4-W E/MDSX
DB9SERIAL
Channel Bank
Mutual AidChannelOptional Mutual Aid
MasterSite
ASTROASTRO 25 Simulcast Prime 25 Simulcast Prime SiteSite
-
ASTROASTRO 25 Simulcast Remote 25 Simulcast Remote SiteSite
ChannelBank
Router
Hub
WANSWITCH
T1/FT1
IR IR
V.35
10/100 BaseTX
10 Base2
V.24
-
Networking Products Vendor Networking Products Vendor Model Reference ListModel Reference List
Product Vendor ModelDigital Cross Connect Switch - existingcustomers(For existing 5.0 & 5.1 customers only)
Tellabs 530 Series
Digital Cross Connect Switch - new customers Zhone ARCA-DACS 100WAN Switch Nortel 7480IR Site Router Motorola ST4000Simulcast Remote Site Router Motorola ST4000Simulcast Prime Site Router Motorola ST5598Core Router Motorola ST5594Control Router Motorola ST5500MGEG Router Motorola ST5500Data Router Motorola ST5500Remote AccessElite LAN and Zone Manager
Motorola ST4000, ST5580,ST5590, ST5598
Ethernet Switch/Enterprise Ethernet Switch Cisco 6509Hubs 3Com PS40Desktop Switches 3Com 1100Modems Paradyne 3810Terminal Servers (Out of Band Management,Analog Access) Nbase-Xyplex
MX-1604, MX1608,MX1620
WAN Switch Management Application Nortel Preside MDMLAN Switch Management Cisco CiscoWorksRouter Management Motorola 9000 OMS
-
CapacitiesCapacitiesandand
ConfigurationsConfigurations
-
System TypesSystem Types
Analog Frequency Bands Supported(Conventional Mutual Aid)
800 MHz
Digital Frequency Bands Supported 800 MHzDigital System Encryption TypesSupported
DES-OFBDES-XL
Trunking Control Channel Rate 9600 baudDigital Vocoder IMBE
-
System CapacitiesSystem Capacities
Number of Zones 7Number of Sites/Subsystems 64Number of Individual IDs 64,000Number of Talkgroup IDs 16,000Max. Channels Per RF Site (IR) 28Max. Channels per RF Site (Simulcast) 30
-
Project 25 ID StructureProject 25 ID Structure
Partitioning is no longer supported or Partitioning is no longer supported or neededneeded
Wide Area Communication Network ID Wide Area Communication Network ID (WACN ID)(WACN ID)
System IDSystem ID Radio Frequency Subsystem (RFSS) ID Radio Frequency Subsystem (RFSS) ID Site IDSite ID
-
Project 25 ID StructureProject 25 ID Structure
Subscriber Unit Identifier (SUID) Subscriber Unit Identifier (SUID) Talkgroup ID/Talkgroup ID/MultiGroupMultiGroup IDIDWorking Unit Identifier (WUID)Working Unit Identifier (WUID)Group IDGroup ID
Subscriber Group Identifier (SGID)Subscriber Group Identifier (SGID) Working Group Identifier (WGID)Working Group Identifier (WGID)
-
Underlying TechnologiesUnderlying Technologies
-
Frame Relay and Asynchronous Frame Relay and Asynchronous Transmission ModeTransmission Mode FR for Intra MSOFR for Intra MSOATM for Inter MSO ATM for Inter MSO Connection OrientedConnection Oriented Permanent Virtual Circuits (PVCs)Permanent Virtual Circuits (PVCs) IMAIMA
-
PSTN /PBX
IP MulticastIP Multicast
IPNetwork
-
Call ProcessingCall Processing
-
Basic Call ExampleBasic Call Example
PSTN
ZoneControllers
PacketData G/W
(Hardware Only)
TelephonyG/W(R6.0)
ZoneNetwork Management System
Servers/Consoles
Co-locatedSystem NMS
Servers/Consoles
Other MSO(s)
S400Site RouterS594Core Routers
Rendezvous RoutersExit Routers
S400Site Router
S500Data Router
Nortel Passport 7400WAN Switch
Cisco 6509Catalyst
LAN Switch
IMA
IMA
Dispatch Site(Gold Console R6.0)
MGEG
AEB
CEB
S500MGEG Router
S500Control Router
S400Site Router
S1100Switch
Conventional/Mutual Aid
DACS
1. Call Request
2. Assign Group Address in Grant
3. Join IP Group
-
Basic Call ExampleBasic Call Example
PSTN
ZoneControllers
PacketData G/W
(Hardware Only)
TelephonyG/W(R6.0)
ZoneNetwork Management System
Servers/Consoles
Co-locatedSystem NMS
Servers/Consoles
Other MSO(s)
S400Site RouterS594Core Routers
Rendezvous RoutersExit Routers
S400Site Router
S500Data Router
Nortel Passport 7400WAN Switch
Cisco 6509Catalyst
LAN Switch
IMA
IMA
Dispatch Site(Gold Console R6.0)
MGEG
AEB
CEB
S500MGEG Router
S500Control Router
S400Site Router
S1100Switch
Conventional/Mutual Aid
DACS4. Multicast Routes Determined by IP Network
5. Vocoded Audio put in IP Packets with Group Address
6. IP Network Distributes Packets Along Multicast Tree
7. Comeback Along Same Tree
8. Leave IP Group
-
Familiar ProcessesFamiliar Processes
Call RequestCall Request Call SetupCall SetupAudio RoutingAudio Routing Call Maintenance and ContinuationCall Maintenance and Continuation Call Termination and Call Termination and TeardownTeardown
-
Subscriber RadiosSubscriber Radios
-
XTS XTS 2500 Portable Radio2500 Portable Radio Signaling Types Signaling Types
SupportedSupported ASTRO 9600ccASTRO 9600cc ASTRO 3600cc Trunking ASTRO 3600cc Trunking
Scan FeaturesScan Features nonprioritynonpriority scan with 1 scan with 1
scan list scan list and 10 entries in the listand 10 entries in the list
Talk Group ScanTalk Group Scan Conventional ScanConventional Scan
Key Software FeaturesKey Software Features Call Alert Call Alert Private callPrivate call Telephone Interconnect Telephone Interconnect
Emergency AlertEmergency Alert
-
Signaling Types SupportedSignaling Types Supported ASTRO 3600cc Analog Trunking ASTRO 3600cc Analog Trunking ASTRO 3600cc Digital Trunking ASTRO 3600cc Digital Trunking ASTRO 25 9600cc Trunking ASTRO 25 9600cc Trunking APCO P25 Digital ConventionalAPCO P25 Digital Conventional Analog Conventional Analog Conventional
Scan FeaturesScan Features both priority and nonboth priority and non--priority scan: 32 priority scan: 32
scan lists and 15 entries per list.scan lists and 15 entries per list. Talk Group ScanTalk Group Scan Conventional ScanConventional Scan
Key Software FeaturesKey Software Features Call Alert Call Alert Private callPrivate call Telephone Interconnect Telephone Interconnect Emergency AlertEmergency Alert
XTS XTS 5000 Portable Radio5000 Portable Radio
-
Module 3Module 3Platform ComparisonsPlatform Comparisons
iDENiDENOpenSkyOpenSky
-
Project 25 vs. OpenSky Project 25 vs. OpenSky loading and capacityloading and capacity
Site 1 Site 2
Site 3
1 2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
1
1
Site 1 Site 2
Site 3
1 2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
10 11 12 1314 15 16CC VC VC VC VC VC VC VC
CC VC VC VC VC VC VC VC
9
18 19 20 21 22 2317
Simulcast System Requires Only 8 RF ChannelsTo Provide 7 Talkpaths Across Entire Coverage Area
A Multi-cast System Requires 24 RF ChannelsTo Provide 7 Talkpaths Across Entire Coverage Area
24
Site 1 Site 2
Site 3
1 2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
1
1
Site 1 Site 2
Site 3
1 2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
10 11 12 1314 15 16CC VC VC VC VC VC VC VC
CC VC VC VC VC VC VC VC
9
18 19 20 21 22 2317
Simulcast System Requires Only 8 RF ChannelsTo Provide 7 Talkpaths Across Entire Coverage Area
A Multi-cast System Requires 24 RF ChannelsTo Provide 7 Talkpaths Across Entire Coverage Area
24
-
Project 25 vs. OpenSky Project 25 vs. OpenSky loading and capacityloading and capacity
Site 1 Site 2
Site 3
1 2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
10 11 12 1314 15 16CC VC VC VC VC VC VC VC
9
CC VC VC
18 1917
Site 1 Site 2
Site 3
1 2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
10 11 12 1314 15 16CC VC VC VC VC VC VC VC
9
CC VC VC
18 1917
CC VC VC
18 1917
-
Project 25 vs. OpenSky Project 25 vs. OpenSky loading and capacityloading and capacity
Site 1 Site 2
Site 3
1 2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
1
1
Site 1 Site 2
Site 3
1 2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
1
1
Trunked SimulcastTrunked Simulcast with 30% blockingwith 30% blocking 7 voice channels7 voice channels system capacity is system capacity is 5.9 5.9
ErlangsErlangs no degradation due no degradation due
to group callsto group calls
-
Site 1 Site 2
1 2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
11 2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
1
Site 3
2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
1
Site 3
2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
1
Site 3
2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
1 2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
1
Site 3
2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
1
Site 3
2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
1
Site 3
2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
1 2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
1
Site 3
2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
1
Site 3
2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
1
Site 3
2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
1 2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
1
Site 3
2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
1
Site 3
2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
1
Site 3
2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
1 2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
1
Site 3
2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
1
Site 3
2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
1
Site 3
2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
1 2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
1
Site 3
2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
1
Site 3
2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
1
Site 3
2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
1 2 3 4 5 6 7 8CC VC VC VC VC VC VC VC
1
Project 25 vs. OpenSky Project 25 vs. OpenSky loading and capacityloading and capacity
Trunked SimulcastTrunked Simulcast with 30% blockingwith 30% blocking 8 channels used8 channels used 7 voice channels7 voice channels system capacity is system capacity is 5.9 5.9
ErlangsErlangs no degradation due no degradation due
to group callsto group calls
-
OpenSkyOpenSky with 30% blockingwith 30% blocking 8 channels used8 channels used 2 timeslots per site2 timeslots per site site capacity is 1.09 site capacity is 1.09
ErlangsErlangs system capacity is 8.8 system capacity is 8.8
ErlangsErlangs
1 2TSTS
1 2TSTS
1 2TSTS
1 2TSTS
1 2TSTS
1 2TSTS
1 2TSTS
1 2TSTS
Project 25 vs. OpenSky Project 25 vs. OpenSky loading and capacityloading and capacity
Assumes uniform Assumes uniform distribution and no distribution and no group calls!group calls!
-
OpenSkyOpenSky typical Public Safetytypical Public Safety calls light up 2 sitescalls light up 2 sites
4.4 Erlangs4.4 Erlangs
calls light up 3 sitescalls light up 3 sites 2.9 Erlangs2.9 Erlangs
calls light up all sitescalls light up all sites 1.09 Erlangs1.09 Erlangs
1 2TSTS
1 2TSTS
1 2TSTS
1 2TSTS
1 2TSTS
1 2TSTS
1 2TSTS
1 2TSTS
Project 25 vs. OpenSky Project 25 vs. OpenSky loading and capacityloading and capacity
-
Key Points:Key Points: Simulcast best where there is a large area to cover Simulcast best where there is a large area to cover
with a small number of radio channels. with a small number of radio channels. Unequal load distribution causes problems with Unequal load distribution causes problems with
OpenSky, but is not an issue with simulcast.OpenSky, but is not an issue with simulcast. Group calls cause inefficiencies with OpenSky, but Group calls cause inefficiencies with OpenSky, but
are not an issue with simulcast. are not an issue with simulcast. Coverage is enhanced by the inherent 3 dB Coverage is enhanced by the inherent 3 dB
advantage that FDMA has over TDMAadvantage that FDMA has over TDMA
Project 25 vs. OpenSky Project 25 vs. OpenSky loading and capacityloading and capacity
-
Project 25Project 25vs. vs. OpenSky OpenSky TechnologyTechnologySummarySummary
Project 25 OpenSkyConventional YES YESTrunked YES YESTechnology FDMA TDMAStandards Body APCO/TIA/ANSI ProprietaryVocoder IMBE AMBEAnalog Mode YES YES150 Mhz YES NO220 Mhz NO NO450 Mhz YES NO700 Mhz NO
(P25 Will beInterop Mode)
NO
800 Mhz YES YES900 Mhz NO NOChannel Bandwidth andSpectrum Eff. (25 Khz)
12.5 Khz -2:1 20/25 Khz - 2:1
Max. Channels/Site 28 IR/30 Simul ??Sites Supported 64 ??Total IDs Available 64,000 ??Users/TGs Supported 16,000 >100KSingle Site Multi Chnl. YES YESMulti Site Multi Chnl. YES YESSimulcast YES NORelative Coverage 25 Khz 100% Approx. 90%Relative Coverage 12.5 Khz 100% N/A
-
Project 25 vs. OpenSky Project 25 vs. OpenSky IVD and throughputIVD and throughput
Project 25 OpenSkyIntegrated Data YES YESChannel Bit Rate 9.6 Kbps 19.2 KbpsUser Data Throughput(Protected Mode)
7.2 Kbps 7.2 Kbps Outbound3.1 Kbps Inbound
IP Subscriber Interface YES YESIP Host Interface YES YESSupport TCP/IP Apps YES YESBuilt-in Compression YES NOShort Message Service YES External ApplicationStatus/Message YES External ApplicationOTAR YES YES
-
Project 25 OpenSkyUnit Registration YES YESGroup Call YES YESPrivate Call YES YESCall Alert YES YESMultiGroup Call YES YESDedicated Control Channel YES NOEmergency Call/Alarm YES YES *Priority Access YES YES *Talkgroup Scan YES YESAutomatic Roaming YES YESEncryption YES YESInterconnect YES Not SeenTalk-Around YES YESVehicular Repeater YES YESLegacy Analog Support YES YESTalkgroup Merge YES NOSelective Radio Inhibit YES YESDynamic Regrouping YES YES
Project 25 vs. OpenSky Project 25 vs. OpenSky features/functionsfeatures/functions
* Access to these could be limited due to lack of dedicated control channel or timeslot.
-
Project 25 vs. iDENProject 25 vs. iDEN
Mission Critical
Business Critical
Shared Network
Prevent loss of life Resources critical to future
Enable business
Integrated systemMultiple services
Asset
Convenience No value to owning spectrum
Dispatch-centricP25 Interoperability
Improve public safety response
Greater business efficiencies
Value Proposition StorylineBenefit
Spectrum position
CRITICALITY
iDEN (very wide area)Harmony (small- wide area)
ASTRO 25
NextelClearNet
Commodity pricing
Low
High
-
Project 25 vs. iDENProject 25 vs. iDENHarmony ASTRO 25 Trunking
Target Market Commercial/Industrial Public safety/ Gov
Digital Yes (TDMA) Project 25 (FDMA)
Carrier Bandwidth 25 kHz 12.5 kHz
Talkpaths 3(IC) or 6 2
Max # of sites 8 (16 Release 2) 48
Interoperability iDEN/Nextel backward compatible, P25
Talkaround No Yes
Vocoder VSELP IMBE
Simulcast No Yes
-
Project 25 vs. iDENProject 25 vs. iDENHarmony ASTRO Trunking
Coverage (street) ~3 sites 1
Emergency Call Yes Yes
Emergency Alarm No Yes
Console wireless wireline
Scan Yes Yes (priority)
Base Station 70 Watts 100 Watts
Mobile 3 Watts 15-35 Watts
Portable .6 - 1 Watt 1-5 Watts
-
Module 4Module 4Supporting ASTRO 4.1 Supporting ASTRO 4.1
SystemsSystems
-
ASTRO SmartZone and ASTRO SmartZone and SmartZone OmniLink 4.1SmartZone OmniLink 4.1 Release 4.1Release 4.1
single zone, similar to SmartZone 3.0single zone, similar to SmartZone 3.0 Release 4.1.1Release 4.1.1
multiple zone, similar to SmartZone multiple zone, similar to SmartZone OmnilLink OmnilLink 3.53.5
Both 4.1 releases are updated with new Both 4.1 releases are updated with new hardware.hardware.
-
Review current releasesReview current releases SmartZone 3.0SmartZone 3.0
single zone, analog, digital and mixed modesingle zone, analog, digital and mixed mode enhanced SmartZone featuresenhanced SmartZone features Sun/IMP Zone ControllerSun/IMP Zone Controller
SmartZone OmniLink 3.5SmartZone OmniLink 3.5 multimulti--zone, analog, digital and mixed modezone, analog, digital and mixed mode enhanced SmartZone featuresenhanced SmartZone features Sun/IMP Zone ControllerSun/IMP Zone Controller
-
Snapshot Release 4.1Snapshot Release 4.1
New Zone New Zone ControllerController
New Server New Server Hardware and Hardware and Operating SystemOperating System
Changes to Feature Changes to Feature SetSet
-
New Zone Controller ...New Zone Controller ...
CompactPCI platformCompactPCI platform 64 ports (vs. 48)64 ports (vs. 48) Fault tolerance replaced by redundant Fault tolerance replaced by redundant
configurationsconfigurations ported through Redundant Switch over ported through Redundant Switch over
ModuleModuleMCG chassis, SunMCG chassis, Sun cPCIcPCI busbus
-
RedundantRedundantZone ControllerZone Controller
Controller 1
Controller 2
Redundant Switch-Over
Module
60/62 max22
60/62 max22
ethernetsync
async
HA Negotiation
MOSCAD
UPS
MZC 3000
DataBroadcast
BoxesDIUs
TelephoneInterconnect
Device
ChannelBanks
AEB
Ethernet Switch
Network Management/Backup Negotiation
HadaxControls
Switch 1(and 2, ifpresent) Ethernet
InterzoneLinks
Router Router
WAN Switch
ConsoleNetworkInterface
Elite Hosts
ToSites
ToEliteOPs
ToZones
ZDS
ATR
ZSS
UCS
INM
SSS
unattendedshut down
8max60/62max
8max
2 sync
Zone
Lev
elSy
stem
Leve
l
-
New Server Hardware on PCI New Server Hardware on PCI ArchitectureArchitectureASTRO 4.1 ServersASTRO 4.1 Servers
ZoneZone--Level Servers:Level Servers:ZDS ZDS ---- Zone Database ServerZone Database ServerFVS FVS ---- FullVison FullVison INM ServerINM ServerATR ATR ---- Air Traffic Router Server (NEW)Air Traffic Router Server (NEW)ZSS ZSS ---- Zone Statistical Server (NEW)Zone Statistical Server (NEW)
System Level ServersSystem Level ServersUCS UCS ---- User Configuration ServerUser Configuration ServerSSS SSS ---- System Statistical Server (Multi zone System Statistical Server (Multi zone
only) (NEW)only) (NEW)
-
New Operating SystemsNew Operating Systems
SOLARIS operating systemSOLARIS operating systemWindows 2000:Windows 2000:
for dispatch operator positionfor dispatch operator position Network Management terminalsNetwork Management terminals
-
Changes to Feature Set ...Changes to Feature Set ...
Feature set is based on Release 3.5 Feature set is based on Release 3.5 OmniLink softwareOmniLink software
There are some Release 3.0 features There are some Release 3.0 features that were never implemented in 3.5 that were never implemented in 3.5 (These features are called SmartZone (These features are called SmartZone Delta Features)Delta Features)
-
Changes to Feature Set ...Changes to Feature Set ...
Delta features ADDED for 4.1Delta features ADDED for 4.1 Automatic Landline to Talkgroup Automatic Landline to Talkgroup
InterconnectInterconnect Remote Monitor by a ConsoleRemote Monitor by a Console
-
Changes to Feature Set ...Changes to Feature Set ...Delta features NOT SUPPORTED Delta features NOT SUPPORTED
for 4.1for 4.1
Manual Busy OverrideManual Busy Override Auto Interrupt On Auto Interrupt On
PriorityPriority Dispatcher InterruptDispatcher Interrupt Talkgroup Repeat Talkgroup Repeat
DisableDisable Sitewide Calls from a Sitewide Calls from a
ConsoleConsole
Tactical Priority Tactical Priority Assignment from a Assignment from a ConsoleConsole
Critical UserCritical User Important User Important User
AccessAccess SecurnetSecurnet
-
Changes to Feature Set ...Changes to Feature Set ...
Console Telephone Console Telephone Patch TimePatch Time--out Timerout Timer
Busy Override from a Busy Override from a ConsoleConsole
Third Party Call AlertThird Party Call Alert Call Alert Storm PlansCall Alert Storm Plans
FallBack Master with FallBack Master with Manual SwitchoverManual Switchover
Failsoft by Talkgroup Failsoft by Talkgroup for One Sitefor One Site
Multiple Site Only Multiple Site Only Calls by TalkgroupCalls by Talkgroup
Emergency All CallEmergency All Call
Delta features NOT SUPPORTED Delta features NOT SUPPORTED for 4.1for 4.1
-
Changes to Feature Set ...Changes to Feature Set ...
New Feature 64,000 Individual IDsNew Feature 64,000 Individual IDs ImplicationsImplications
be careful with loading profilebe careful with loading profile increased download time from UCS to increased download time from UCS to
zoneszones
-
Possible ConfigurationsPossible Configurations
Single Zone Type: 1A configurationsSingle Zone Type: 1A configurations
Z1
Config. IA
-
Possible ConfigurationsPossible Configurations
MultiMulti--zone: zone: CoCo--located Configurations: IIA, IIIA, IVAlocated Configurations: IIA, IIIA, IVA
Z1 Z2MS A
Config. IIA
MS A
Z1
Z3
Z2
Config. IIIA
MS A
Z1 Z3Z2
Config. IVA
Z4
-
Possible ConfigurationsPossible Configurations
MultiMulti--zone: zone: Remote Zone Configurations: IIB, IIIC and Remote Zone Configurations: IIB, IIIC and
IVD IVD
MS A MS B
Z1 Z2MS A
MS C
MS B
Z1
Z3
Z2
OMS A
MS C MS D
OMS B
Z1
Z3 Z4
Z2
Config.
Config.
Config.
-
Possible ConfigurationsPossible Configurations
Single Zone Type: 1A configurationsSingle Zone Type: 1A configurationsMultiMulti--zone: zone:
MixedMixed ColocatedColocated/Remote Zone /Remote Zone Configurations: II/IB, II/IIB and II/I/ICConfigurations: II/IB, II/IIB and II/I/IC
MS A
MS B
Z1 Z2
Z3
Config. II/IB
MS B
MS A
Z1 Z2
Config. II/IIB
Z3 Z4
Config. II/I/IC
MS CMS B
MS A
Z1
Z3 Z4
Z2
-
Modulation Frequency BandAnalog VHF, UHF, 800, 900
Analog, MTR 335-405 AsiaASTRO CAI VHF, UHF, 800
ASTRO CAI and Clear Analog VHF, UHF, 800Encrypted ASTRO CAI only VHF, UHF, 800
Clear Analog, Encrypted ASTRO CAI,ASTRO CAI
VHF, UHF, 800
Clear Analog, Encrypted ASTRO CAI, VHF, UHF, 800
Single and Multi ZoneSingle and Multi Zone
-
Module 5Module 5MigrationMigration
-
Subscriber ConsiderationsSubscriber Considerations
3.0/3.5 to 4.13.0/3.5 to 4.1 Complete interchangeability, except for Complete interchangeability, except for
system feature set differences noted in system feature set differences noted in Module 4Module 4
3.0/3.5 to 6.03.0/3.5 to 6.0 Legacy subscriber radios cannot be flash Legacy subscriber radios cannot be flash
upgraded beyond Release 5.1upgraded beyond Release 5.1
-
SmartZone MigrationSmartZone Migration Reuse:Reuse:
RF Site EquipmentRF Site Equipment SubscribersSubscribers Gold Elite and Gold Gold Elite and Gold
Series Button/LED Series Button/LED Consoles, and Consoles, and AEB/CEBAEB/CEB
Master Site Channel Master Site Channel Banks/DACS/Banks/DACS/DIUsDIUs
MBeX MBeX and Nova and Nova 20002000
New:New: MZC 3000 Zone MZC 3000 Zone
Controller and Controller and Switchover ModuleSwitchover Module
Upgrades to Upgrades to DIUsDIUs, , AEB/CEBAEB/CEB
MTC 3600 Site MTC 3600 Site Controller (retain Controller (retain 6809 in some 6809 in some configurationsconfigurations
Network Network Management Management EquipmentEquipment
-
ZONE CONTROLLER
DATABASE SERVER
xTERMINAL
USER SERVER
CHANNELBANK
DATA BROADCAST
BOXESDIUs
AEB
CHANNELBANK
MBx
T1/E1 DACS
TO PSTN
TO SITES
TeNSr
CEB DISPATCH OPERATOR
ADMCDM
SERVER
ELITE HUB
Figure 2.2A ASTRO SmartZone 3.0 Master Site (Before Upgrade)
ETHERNET SWITCH
ZONE CONTROLLER
DATABASE SERVER
xTERMINAL
USER SERVER
CHANNELBANK
DATA BROADCAST
BOXESDIUs
AEB
CHANNELBANK
MBx
T1/E1 DACS
TO PSTN
TO SITES
TeNSr
CEB DISPATCH OPERATOR
ADMCDM
SERVER
ELITE HUBETHERNET SWITCH
Upgrade SmartZone 3.0 Upgrade SmartZone 3.0 Master SiteMaster Site
Before Upgrade
-
CEB DISPATCHOPERATOR
ADMCDM
SERVER
ELITE HUB
CHANNELBANK
DATA BROADCAST
BOXESDIUs
AEB
CHANNELBANK
MBx
T1/E1DACS
TO PSTN
TO SITESTeNSr
ZONE CONTROLLER
1
ZONECONTROLLER
2
REDUNDANTSWITCH
OVERMODULE
ETHERNET SWITCH
UCS
FV/INM
UPS MZC 3000
InterzoneLinks
Hadax control
ethernetMOSCAD
(OPTIONAL)
network managementBackup Negotiation
Asyncsync
NEGOTIATION
ZDS
ZSS
ATR
WIN2000
CLIENT
Figure 2.2B ASTRO SmartZone 4.1 Master Site (After Upgrade)
TERMINALSERVER
CEB MBX
TeNSr
CEB DISPATCHOPERATOR
ADMCDM
SERVER
ELITE HUB
CHANNELBANK
DATA BROADCAST
BOXESDIUs
AEB
CHANNELBANK
MBx
T1/E1DACS
TO PSTN
TO SITESTeNSr
CEB DISPATCHOPERATOR
ADMCDM
SERVER
ELITE HUB
CHANNELBANK
DATA BROADCAST
BOXESDIUs
AEB
CHANNELBANK
MBx
T1/E1DACS
TO PSTN
TO SITESTeNSr
ZONE CONTROLLER
1
ZONECONTROLLER
2
REDUNDANTSWITCH
OVERMODULE
ETHERNET SWITCH
UCS
FV/INM
UPS MZC 3000
InterzoneLinks
Hadax control
ethernetMOSCAD
(OPTIONAL)
network managementBackup Negotiation
Asyncsync
NEGOTIATION
ZDS
ZSS
ATR
WIN2000
CLIENT
Figure 2.2B ASTRO SmartZone 4.1 Master Site (After Upgrade)
TERMINALSERVER
CEB MBX
TeNSr
ZONE CONTROLLER
1
ZONECONTROLLER
2
REDUNDANTSWITCH
OVERMODULE
ETHERNET SWITCH
UCS
FV/INM
UPS MZC 3000
InterzoneLinks
Hadax control
ethernetMOSCAD
(OPTIONAL)
network managementBackup Negotiation
Asyncsync
NEGOTIATION
ZDS
ZSS
ATR
WIN2000
CLIENT
Figure 2.2B ASTRO SmartZone 4.1 Master Site (After Upgrade)
TERMINALSERVER
CEB MBX
TeNSr
Upgrade SmartZone 3.0 Upgrade SmartZone 3.0 Master SiteMaster Site
AfterUpgrade
-
Upgrading Upgrading IntelliRepeaterIntelliRepeater SitesSites
Quantar
SRU 4W Audio
WAN CARD TeNSrT1/E1To MasterSite
QuantarQuantar
10 Base-2 Ethernet
ADPCM
Control Data,Async, 9.6 kbps
Quantar
SRU 4W Audio
WAN CARD TeNSrT1/E1To MasterSite
QuantarQuantar
10 Base-2 Ethernet
ADPCM
Control Data,Async, 9.6 kbps
Quantar
SRU 4W Audio
WAN CARD TeNSrT1/E1To MasterSite
QuantarQuantar
10 Base-2 Ethernet
ADPCM
Control Data,Async, 9.6 kbps
Quantar
SRU 4W Audio
WAN CARD TeNSrT1/E1To MasterSite
QuantarQuantar
10 Base-2 Ethernet
ADPCM
Control Data,Async, 9.6 kbps
Quantar
SRU 4W Audio
WAN CARD TeNSrT1/E1To MasterSite
QuantarQuantar
10 Base-2 Ethernet
ADPCM
Control Data,Async, 9.6 kbps
Quantar
SRU 4W Audio
WAN CARD TeNSrT1/E1To MasterSite
QuantarQuantar
10 Base-2 Ethernet
ADPCM
Control Data,Async, 9.6 kbps
Quantar
SRU 4W Audio
WAN CARD TeNSrT1/E1To MasterSite
QuantarQuantar
10 Base-2 Ethernet
ADPCM
Control Data,Async, 9.6 kbps
Quantar
SRU 4W Audio
WAN CARD TeNSrT1/E1To MasterSite
QuantarQuantar
10 Base-2 Ethernet
ADPCM
Control Data,Async, 9.6 kbps
Quantar
SRU 4W Audio
WAN CARD TeNSrT1/E1To MasterSite
QuantarQuantar
10 Base-2 Ethernet
ADPCM
Control Data,Async, 9.6 kbps
-
Upgrading Standalone 6809 SitesUpgrading Standalone 6809 Sites
T1/E1To MasterSite
ControlData,Async, 9.6 kbps
6809 RemoteController orNEW MTC3600
Quantar
DataBroadcast
Quantar Quantar
SRU 4W Audio
WAN CARD TeNSr
ADPCMT1/E1To MasterSite
ControlData,Async, 9.6 kbps
6809 RemoteController orNEW MTC3600
Quantar
DataBroadcast
Quantar Quantar
SRU 4W Audio
WAN CARD TeNSr
ADPCMT1/E1To MasterSite
ControlData,Async, 9.6 kbpsControlData,Async, 9.6 kbps
6809 RemoteController orNEW MTC3600
Quantar
DataBroadcast
Quantar Quantar
SRU 4W Audio
WAN CARD TeNSr
ADPCM
SRU 4W Audio
WAN CARD TeNSr
ADPCM
Site
T1/E1To MasterSite
ControlData,Async, 9.6 kbps
6809 RemoteController orNEW MTC3600
Quantar
DataBroadcast
Quantar Quantar
SRU 4W Audio
WAN CARD TeNSr
ADPCM
Site
T1/E1To MasterSite
ControlData,Async, 9.6 kbpsControlData,Async, 9.6 kbps
6809 RemoteController orNEW MTC3600
Quantar
DataBroadcast
Quantar Quantar
SRU 4W Audio
WAN CARD TeNSr
ADPCM
SRU 4W Audio
WAN CARD TeNSr
ADPCM
-
Upgrading Simulcast Prime SiteUpgrading Simulcast Prime Site
6809 Prime Or MTC3600
GPSRubidium
ASTRO-TAC 3000
DataBroadcast
Ch1 USCI
SRU DSM II
WAN CARD
SRU 4W to Voice
WAN CARD ADPCM
SRU DSM II
WAN CARD
Site 1Site 2
To Site 1T1/E1 To Site 2T1/E1
To MasterSite
T1/E1
TeNSrTeNSr
TeNSr
1pps
Ch1 SDAOptional
Extended T1(if Extended Broadcast used)
6809 Prime Or MTC3600
GPSRubidium
ASTRO-TAC 3000
DataBroadcast
Ch1 USCI
SRU DSM II
WAN CARD
SRU 4W to Voice
WAN CARD ADPCM
SRU DSM II
WAN CARD
Site 1Site 2
To Site 1T1/E1 To Site 2T1/E1
To MasterSite
T1/E1
TeNSrTeNSr
TeNSr
1pps
Ch1 SDAOptional
Extended T1(if Extended Broadcast used)
BeforeUpgrade
-
6809 Prime Or MTC3600
GPSRubidium
ASTRO-TAC 3000
DataBroadcast
Ch1 USCI
SRU DSM II
WAN CARD
SRU 4W to Voice
WAN CARD ADPCM
SRU DSM II
WAN CARD
Site 1Site 2
To Site 1T1/E1 To Site 2T1/E1
To MasterSite
T1/E1
TeNSrTeNSr
TeNSr
1pps
Ch1 SDAOptional
Extended T1(if Extended Broadcast used)
6809 Prime Or MTC3600
GPSRubidium
ASTRO-TAC 3000
DataBroadcast
Ch1 USCI
SRU DSM II
WAN CARD
SRU 4W to Voice
WAN CARD ADPCM
SRU DSM II
WAN CARD
Site 1Site 2
To Site 1T1/E1 To Site 2T1/E1
To MasterSite
T1/E1
TeNSrTeNSr
TeNSr
1pps
Ch1 SDAOptional
Extended T1(if Extended Broadcast used)
Upgrading Simulcast Prime SiteUpgrading Simulcast Prime Site
AfterUpgrade
-
Upgrading Simulcast Remote SiteUpgrading Simulcast Remote Site
To Prime
6809 RemOr MTC3600 Quantar
SRU DSM II
WAN CARD TeNSrT1/E1Site
GPS Rubidium
1 pps 5 MHz
To Prime
6809 RemOr MTC3600 Quantar
SRU DSM II
WAN CARD TeNSrT1/E1Site
GPS Rubidium
1 pps 5 MHz
To Prime
6809 RemOr MTC3600 Quantar
SRU DSM II
WAN CARD TeNSrT1/E1Site
GPS Rubidium
1 pps 5 MHz
To Prime
6809 RemOr MTC3600 Quantar
SRU DSM II
WAN CARD TeNSrT1/E1Site
GPS Rubidium
1 pps 5 MHz
To Prime
6809 RemOr MTC3600 Quantar
SRU DSM II
WAN CARD TeNSrT1/E1Site
GPS Rubidium
1 pps 5 MHz
To Prime
6809 RemOr MTC3600 Quantar
SRU DSM II
WAN CARD TeNSrT1/E1Site
GPS Rubidium
1 pps 5 MHz
-
Upgrading OmniLink Upgrading OmniLink Master SiteMaster Site
ZONE CONTROLLER
WITH SZ OMNILINK
SOFTWARE
CADISERVER
CADIROUTER
USERTERMINALS
USER SERVER
ZDS
UCS
FULLVISION MOSCAD
SSC
NETWORK MANAGEMENT SYSTEM
DATA BROADCAST
BOXESDIUs CHANNELBANK
MBxTO PSTN
EHTERNET SWITCHWAN
CEB DISPATCHOPERATOR
ADMCDM
SERVER
ELITE HUB
CHANNELBANK AEB
T1/E1 DACS
TO SITES
TeNSr
ROUTER
TO OTHER ZONES
ZONE CONTROLLER
WITH SZ OMNILINK
SOFTWARE
CADISERVER
CADIROUTER
USERTERMINALS
USER SERVER
ZDS
UCS
FULLVISION MOSCAD
SSC
NETWORK MANAGEMENT SYSTEM
DATA BROADCAST
BOXESDIUs CHANNELBANK
MBxTO PSTN
EHTERNET SWITCHWAN
CEB DISPATCHOPERATOR
ADMCDM
SERVER
ELITE HUB
CHANNELBANK AEB
T1/E1 DACS
TO SITES
TeNSr
ROUTER
TO OTHER ZONES
ZONE CONTROLLER
WITH SZ OMNILINK
SOFTWARE
CADISERVER
CADIROUTER
USERTERMINALS
USER SERVER
ZDS
UCS
FULLVISION MOSCAD
SSC
NETWORK MANAGEMENT SYSTEM
USER SERVER
ZDS
UCS
FULLVISION MOSCAD
SSC
NETWORK MANAGEMENT SYSTEM
DATA BROADCAST
BOXESDIUs CHANNELBANK
MBxTO PSTN
EHTERNET SWITCHWAN
CEB DISPATCHOPERATOR
ADMCDM
SERVER
ELITE HUB
CHANNELBANK AEB
T1/E1 DACS
TO SITES
TeNSr
ROUTER
TO OTHER ZONES
BeforeUpgrade
-
Upgrading OmniLink Upgrading OmniLink Master SiteMaster Site
ZONE CONTROLLER
1
ZONECONTROLLER
2
REDUNDANTSWITCH
OVERMODULE
ETHERNET SWITCH
UPS MZC 3000
InterzoneLinks
Hadax control
ethernetMOSCAD
(OPTIONAL)
network managementBackup Negotiation
Asyncsync
NEGOTIATION
WAN TRANSPORT
ROUTER
TO OTHER ZONES
UCS
FV/INM
ZDS
ZSS
ATR
WIN2000
CLIENT
CEB DISPATCHOPERATOR
ADMCDM
SERVER
ELITE HUB
CHANNELBANK
DATA BROADCAST
BOXESDIUs
AEB
CHANNELBANK
MBx
T1/E1DACS
TO PSTN
TO SITESTeNSr
Figure 2.4B ASTRO SmartZone Omnilink 4.1 Master Site (After Upgrade)
SSS
TERMINALSERVER
CEB MBX
TeNSr
ZONE CONTROLLER
1
ZONECONTROLLER
2
REDUNDANTSWITCH
OVERMODULE
ETHERNET SWITCH
UPS MZC 3000
InterzoneLinks
Hadax control
ethernetMOSCAD
(OPTIONAL)
network managementBackup Negotiation
Asyncsync
NEGOTIATION
WAN TRANSPORT
ROUTER
TO OTHER ZONES
UCS
FV/INM
ZDS
ZSS
ATR
WIN2000
CLIENT
CEB DISPATCHOPERATOR
ADMCDM
SERVER
ELITE HUB
CHANNELBANK
DATA BROADCAST
BOXESDIUs
AEB
CHANNELBANK
MBx
T1/E1DACS
TO PSTN
TO SITESTeNSr
Figure 2.4B ASTRO SmartZone Omnilink 4.1 Master Site (After Upgrade)
SSS
TERMINALSERVER
CEB MBX
TeNSr After Upgrade